1.    motor to be exposed to water  Personal  injury andlor death could result  Keep  pump and power cords away from  liquids  Model PC1 becomes very hot  during operation        A DANGER    Do not pump gasoline or  other explosive liquids  Do             not operate pump where  flammable or explosive fumes or gases  are present as a fire or explosion could  result  Pump should only be used to  pump clear water  Do not run pump  dry        1  Read all instructions  before operation     2  Protect electrical cord  from sharp objects  hot  surfaces  oil and chemicals  Avoid  kinking the cord and replace  damaged cords immediately     A CAUTION    with water only                 This pump has been  evaluated for use          REMINDER  Keep your dated proof of purchase for warranty purposes   Attach it to this manual or file it for safekeeping           2008 Wayne Water Systems    For parts  product  amp  service information  visit WwWw waynepumps com    321205 001 11 08       Operating Instructions and Parts Manual       Installation    Models PC1 and PC2 include a 6 foot  long suction hose  a water suction  attachment  and a replacement parts kit  which includes  impeller  gasket  shaft  seal  and two motor brushes  Models  PC1 and PC2 can be used without the  water suction attachment    Always disconnect power source  before attempting to install  service   or maintain the pump  Never handle a  pump with wet hands or when standing    on wet or damp surface or in water   Fatal ele
2.  shown in parts list Harrison  OH 45030 U S A     POWER SWITCH  ON OFF                   12 VOLT POWER CORD  BATTERY TERMINAL    CLAMPS X    D  RETAINING RING   In Replacement Kit        BRUSH CAP    C  SHAFT SEAL   In Replacement Kit  E  BRUSH ASSEMBLY     In Replacement Kit     A  IMPELLER   In Replacement Kit        B  GASKET   In Replacement Kit        COVER PLATE    EF G  6 FT SUCTION HOSE  X  Included with Pump     F  WATER SUCTION ATTACHMENT   Included with pump     Figure 3   Replacement Parts Illustration for Self Priming Transfer Pumps       www waynepumps com    PC1 and PC2 Series       Replacement Parts List for Self Priming Transfer Pumps             Reference Part Number for Models   Number Description PC1 PC2 Quantity  1 Brush and Impeller Kit 66062 WYN1 66058 WYN1  A  Impeller 1  B  Gasket 2  C  Shaft Seal 1  D  Retaining Ring 1  E  Brushes 2  2 Brush Kit 66063 WYN1      E  Brushes 2  3 Water Suction Attachment 66064 WYN1 66064 WYN1  F  Water Suction Attachment 1  G  6 ft  Suction Hose 1    NOTE  Replacement parts are available in kit form only       Www waynepumps com    Operating Instructions and Parts Manual       Limited Warranty    For one year from the date of purchase  Wayne Water Systems     Wayne     will repair or replace  at its option  for  the original purchaser any part or parts of its Sump Pumps or Water Pumps     Product     found upon examination  by Wayne to be defective in materials or workmanship  Please call Wayne  800 237 0987  for instru
3. Operating Instructions  amp  Parts Manual    PC1 and PC2 Series       Please read and save these instructions  Read carefully before attempting to assemble  install  operate or maintain the product described   Protect yourself and others by observing all safety information  Failure to comply with instructions could result in personal injury andlor  property damage  Retain instructions for future reference     WAYNE    Self Priming  Transfer Pumps       Table of Contents    Descripion            0000 eee eee 1  Unpacking    seasann nananana 1  Safety Guidelines                4  1  General Safety Information          1  Installation              000 0c eee 2  Operation               2 022 005  2  Maintenance                  05  3  Troubleshooting Chart              4  Replacement Part Information      6 7  Warranty             0 000 eee ee eee 8  Description    These self priming transfer pumps are  designed to easily transfer water from  one point to another  Model PC1  12  Volt Transfer Pump is convenient when  normal power is not readily available   Typical applications include removing  water from pool covers  clogged  drains  stock tanks  water basins  boats   cisterns  etc  Model PC2  115 Volt  Transfer Pump is great for household  usage  Typical applications include  removing water from waterbeds   clogged sinks  basements  etc  Note  Do  NOT use PC2 in pool areas  The motors  on both models PC1 and PC2 are non   submersible     Unpacking   Inspect this unit before it 
4. ctions or see  your dealer  Be prepared to provide the model and serial number when exercising this warranty  All transporta   tion charges on Products or parts submitted for repair or replacement must be paid by purchaser     This Limited Warranty does not cover Products which have been damaged as a result of accident  abuse  misuse   neglect  improper installation  improper maintenance  or failure to operate in accordance with Wayne s written  instructions     THERE IS NO OTHER EXPRESS WARRANTY  IMPLIED WARRANTIES  INCLUDING THOSE OF MERCHANT   ABILITY AND FITNESS FOR A PARTICULAR PURPOSE  ARE LIMITED TO ONE YEAR FROM THE DATE OF  PURCHASE  THIS IS THE EXCLUSIVE REMEDY AND ANY LIABILITY FOR ANY AND ALL INDIRECT OR CONSE   QUENTIAL DAMAGES OR EXPENSES WHATSOEVER IS EXCLUDED     Some states do not allow limitations on how long an implied warranty lasts  or do not allow the exclusions or  limitations of incidental or consequential damages  so the above limitations might not apply to you  This limited  warranty gives you specific legal rights  and you may also have other legal rights which vary from state to state     In no event  whether as a result of breach of contract warranty  tort  including negligence  or otherwise  shall  Wayne or its suppliers be liable for any special  consequential  incidental or penal damages including  but not  limited to loss of profit or revenues  loss of use of the products or any associated equipment  damage to associated  equipment  cost of ca
5. ctrical shock could occur     1  A ground fault circuit interrupter   GFCI  is required for Model PC2   Risk of electrical shock  This pump is   supplied with a grounding conductor  and grounding type attachment plug   A grounded receptacle in conformance  with current NEC and local codes must  be used  See Figure 1   Do not use  model PC2  115 V Transfer Pump in  swimming pool areas     2  Model PC1 operates on 12V DC only   Model PC2 operates on 115V only   Voltage and current of power supply  must match the requirements of the  pump  Model PC1 has color coded  battery clamps for 12V operation   Model PC1 requires 14 amps at 12  VDC     3  Never use an extension cord to  power this unit     Risk of fatal electrical shock  Never  cut off the round grounding prong   Cutting the cord or plug will void  the warranty and make the pump  inoperable     4  Use a strainer when pumping from a  creek  pond  or source where foreign  objects may be sucked into the  pump  The strainer should prevent  solids from entering the inlet line     5  Aregular garden hose may be used  as a discharge line     6  The inlet or suction hose should  not be longer than 15 feet  and  the vertical distance between the  pump and the water level should  not be any higher than 10 feet  The  maximum discharge height is 30  feet     7  Attimes  an overload due to  overheating  low voltage  jammed    impeller  etc  may shut the pump off     Unplug or turn off the pump and  wait at least ten minutes  The pump  
6. et breaker      Voltage of power supply must match the    voltage of the pump    3  Replace brushes      Remove blockage    5  Disconnect from power supply and allow to    cool  Minimum 10 minutes        Pump will not prime or  retain prime after operating    1  Air leak in suction line      Repair suction line by tightening inlet    connection or replace       2  Impeller blocked 2  Remove blockage  3  Worn seal 3  Replace seal  4  Suction lift too high 4  Lower pump  5  Hose kinked or looped 5  Straighten hose  6  Fittings not tight 6  Tighten fittings  7  Suction hose out of water 7  Submerge suction hose end  8  Clogged inlet 8  Clean inlet  Flow rate is too low 1  Inlet hose plugged or 1  Clean or replace  kinked  2  Low line voltage 2  Voltage of power supply must match the    voltage of the pump       Shaft seal leaks    1  Worn seal  2  Shaft grooved    3  Pump head loose on motor      Replace seal    2  Replace pump    3  Insure proper assembly and no obstruction     tighten bolts          Www waynepumps com    PC1 and PC2 Series          Notes                                                                                                          WWww waynepumps com    Operating Instructions and Parts Manual       For Replacement Parts or Technical Assistance   Call 1 800 237 0987    Please provide following information  Address any correspondence to     Model number Wayne Water Systems    Serial number  if any  101 Production Drive    Part description and number as
7. fully charged automotive tractor or  marine type battery to operate                                      Figure 1    Connect the red clamp to the  positive     type battery terminal   Connect the black clamp to the  negative     type battery terminal   See 12V wiring diagram below   Figure 2   Model PC2  Plug into a  3 prong ground type AC receptacle     Maintenance  Always disconnect    A DANGER  power source    before attempting to install  service  or  maintain the pump     IMPELLER REPLACEMENT    These parts are designed to handle  most clear  nonflammable liquids with  slight amounts of abrasives  When  impeller vanes become worn from use   or damaged due to pumping abrasive  liquids or trash  pump performance will  be reduced or prevented altogether     1  Remove the four cover plate screws  holding motor housing and pump  housing together  Cover plate is  now free and can be removed     2  Inspect gasket and impeller for  wear and damage  If there is any  evidence of wear or damage  replace  the part s     3  Lubricate new impeller with white  grease or lightweight oil and  reinstall by aligning flat on impeller  hub with flat on motor shaft        12 VOLT WIRING DIAGRAM                  BLACK CLAMP  TO NEGATIVE  TERMINAL       RED CLAMP  TO POSITIVE  TERMINAL          POS NEG  12 VOLT DC  BATTERY  12 VOLT DC PUMP  Figure 2    4  Reassemble gasket  cover plate  and  cover plate screws     SHAFT SEAL REPLACEMENT    Motor shafts are sealed with factory  pre lubricated li
8. is used   Occasionally  products are damaged  during shipment  If the pump or  components are damaged  return  the unit to the place of purchase for  replacement  Failure to do so could  result in serious injury or death     READ  amp  FOLLOW ALL INSTRUCTIONS    SAVE THESE INSTRUCTIONS  DO NOT DISCARD    Safety Guidelines   This manual contains information   that is very important to know and  understand  This information is  provided for SAFETY and to PREVENT  EQUIPMENT PROBLEMS  To help  recognize this information  observe the    following symbols   Danger indicates an    ADANGER  ieee  imminently    hazardous situation which  if not  avoided  WILL result in death or serious    injury   Warning indicates a    A WARNING potentially    hazardous situation which  if not  avoided  COULD result in death or    serious injury   Caution indicates a    A CAUTION   oventially    hazardous situation which  if not  avoided  MAY result in minor or    moderate injury   Notice indicates    NOTICE    important    information  that if not followed  may  cause damage to equipment                                         NOTE  Information that requires special  attention     General Safety Information  CALIFORNIA PROPOSITION 65    A WARNING This product or    its power cord may  contain chemicals known to the State  of California to cause cancer and birth  defects or other reproductive harm   Wash hands after handling                 GENERAL SAFETY  Do not submerge    A DANGER  motor or allow 
9. p type seals which are  good for the life of the pump  If the  seal leaks  it is usually because the pump  has handled abrasive liquids  If the  motor shaft is scored  deep grooves    the complete pump must be replaced     1  Remove and inspect impeller parts as  specified in the impeller replacement  instructions  Replace worn parts     2  Remove two pump body mounting  screws and slide pump body from  motor  Pry out seal retaining ring  and push worn shaft seal from inside  of pump body    3  Lubricate new seal with lightweight  oil  push it into pump body with lip  facing away from motor  and push in  seal retaining ring     4  Reassemble pump body onto motor  with mounting screws  Follow steps  3 and 4 in Impeller Replacement     MOTOR BRUSH REPLACEMENT    Brushes for this  NOTICE pump should be    inspected after 75 hours of operation  and replace if worn  They must be  replaced every 100 hours of operation   Service one brush at a time                 1  Disconnect pump from power  supply    2  Remove brush caps with screwdriver    3  Remove old brush assembly    4  Insert new brush assembly    5  Replace brush caps        Wwww waynepumps com    Operating Instructions and Parts Manual       Troubleshooting Chart    Symptom    Pump will not start or run    Possible Cause s     1  Blown fuse    2  Low line voltage    3  Worn brushes  4  Impeller blocked  5  Motor has overheated  Model PC2 only     Corrective Action    1     If blown  replace with proper sized fuse or  res
10. pital  cost of substitute products  facilities  services or replacement power  downtime costs  or  claims of buyer s customers for such damages     You MUST retain your purchase receipt along with this form  In the event you need to exercise a warranty claim   you MUST send a copy of the purchase receipt along with the material or correspondence  Please call Wayne   800 237 0987  for return authorization and instructions     DO NOT MAIL THIS FORM TO WAYNE  Use this form only to maintain your records   MODEL NO  SERIAL NO  INSTALLATION DATE          ATTACH YOUR RECEIPT HERE       Www waynepumps com    
11. will cool and automatically reset    Model PC2 only     8  Motor should never be operated  for more than 2 hours continuously   Critical heating can occur and might  severely damage the pump and void  warranty     Operation   1  Add 1 tablespoon of vegetable oil  to both inlet and outlet to prime   Attach included 6 foot suction hose  to inlet of pump  Attach garden  hose to outlet of pump  There  must be a gasket in place to insure  that these connections are airtight   otherwise the pump will not prime     2  Connect water suction attachment  to the open end of inlet hose and  place below water surface   Water  suction attachment is optional  for both PC1 and PC2 models     The water suction attachment is  designed to fit the male end of   a garden hose  Place the water  suction attachment as near as  possible to the middle of the water  that is to be pumped     3  Examine the inlet and outlet hoses  to insure there are no blockages     kinks or bends   Place switch in    A WARNING    OFF    position    before connecting or disconnecting  battery terminal clamps                       IMPORTANT BATTERY  INFORMATION    Be certain that the area around the  batteries is well ventilated  Before  servicing the batteries  blow away  gasses by waving a piece of cardboard  near the batteries    Dangerous    A DANGER h  drogen gas    can be released from batteries while  charging  Sparks can ignite the gas  in an enclosed space  Wear safety  goggles when connecting batteries   Batter
12. y connections should be made  in a well ventilated area     Working in the   A DANGER vicinity of lead  acid batteries can be dangerous   Before making connections or  servicing the batteries  read and  follow instructions in all applicable  instruction manuals  To reduce the  risk of battery explosion  follow  the instructions in this manual and  those published by the battery  manufacturer  as well as those of  any other equipment used in the  surrounding area     An assistant should be present or  close enough to come to your aid in  the event of an emergency  Have a  reliable source of fresh water and  soap nearby in case battery acid  contacts clothing  skin or eyes     Wear eye and clothing protection  when working around lead acid  batteries     Avoid touching your eyes when  working around lead acid batteries     A WARNING If battery acid    contacts your  eye s   flush with cold running  water for 20 minutes and seek  immediate medical attention  If acid  contacts your skin or clothing  wash  immediately with soap and water                       A WARNING Never smoke or  allow a spark or  flame in the vicinity of the battery   A WARNING   Avoid dropping  metal tools on          the battery posts because they may  spark or short circuit the system or  battery  causing an explosion           Www waynepumps com       PC1 and PC2 Series       Operation  Continued     4  Connect pump to power source   with pump in a dry location  Model  PC1  Motor must be connected to a  
    