Home
Vinotheque 8000 User's Manual
Contents
1. Extreme 8000 Duct Kit A Vinoth EGUE WINE CELLARS 1738 East Alpine Avenue Customer Service Stockton California 95205 1 800 343 9463 www Vinothegue com Protecting Your Investment in Fine Wines Extreme Duct Kit Parts List DuctingAdapter x 1 or 2 IOinch to 8inch reducer x 1 or 2 L LS inches __4 L8 inches __ l Installation Step 1 Remove the grill from the unit by unscrewing the four screws that hold it in place Step 2 Move the Ducting Adapter into place Installation Step 3 Screw the Duct Kit into place using the same screws that held the grill in place Ducted Installation Use ductwork to connect the unit to the supply and return outlets in the wine cellar Use only insulated ductwork to minimize cooling losses prevent sweating and reduce noise Use ductwork on the condenser section to redirect or absorb sound bring in outside air to the unit inlet and or exhaust the hot air out of the ambient space Note Do not exceed a total of 25 for each length of ductwork run and a total of 50 combined for both the supply and return lengths Avoid crimping the flexible ducts This chokes down the inside area and reduces the airflow causing the unit to operate erratically Be sure all ducts and surfaces in contact with the airflow are insulated and have a vapor barrier on the outside Uninsulated ducts and surfaces cause bare exposed metal surfaces to sweat f
2. ductwork from the cellar to the return air inlet adapter flange at the WhisperKOOL Extreme unit Warm Air to from Wine Cellar Y Connect ductwork on the condenser to direct heat and air noise away from occupants Y Connect ductwork to another space within the basement or out of the building if exhausted heat 1s undesirable Standard Ducted Installation Dual Outlet Duct Remote Mount on Floor Outside Remote Mount Attic Mounted System 8 CONDENSER Dy ExHAST fF 22 9 ai SIND SAD 4 SARA S RY dIE fire d peor Wl RA Ten m AN r EM yk Fa LIS ae FRESH AIR n INTAKE SARA ALL LAALA AA LAA AA LA TA SAA OLA LV A LALAAALLLLLA LLC SA ALA LALL ALL LAA LO LLL LI AIR Vimoth gue WINE CELLARS 1738 East Alpine Avenue Stockton California 95205 www vinotheque com WhisperKOOL
3. urther degrading the insulation and equipment cooling capacity General Duct Recommendation V Provide support for the flexible duct to prevent sags and bends v Stretch out the duct to make a smoother interior which reduces air resistance v For 90 bends use a 90 adjustable elbow Ell Y Do not squeeze or reduce the inside diameter of the ducts which reduces airflow v Use short and straight ductwork where possible Y Remove the grilles and panels from the openings to connect the ductwork v Check that all fan blades move freely v Keep air paths free of loose foreign objects and debris Y Connect the round flexible ducts to the WhisperKOOL Extreme using the duct collars provided with the duct accessory kat Y Pull the outer plastic wrapping and insulation away from the end of the duct to expose the reinforced inside duct liner v Fasten the duct collar using tie straps or clamps around the inside liner v Secure the duct collar to the unit using the screws provided Take care to not damage or bend the gasket v Use approved duct tape to seal all joints Do not clamp around the outside insulation It compresses and loosens over time Using Ductwork Cold Air to from Wine Cellar v Remove supply air grille to install ductwork between WhisperKOOL Extreme unit and the cellar Y Connect the supply air ductwork from the cellar to the supply air outlet adapter flange at the WhisperKOOL Extreme unit v Connect the return air
Download Pdf Manuals
Related Search
Related Contents
Bloomfield SW-10T Specifications Nobo Prestige Magnetic Mobile Flipchart Easel Humminbird Ultima Fish Finder User Manual User Manual - Advanced Gas Solutions protocollo di comportamento - Direzione Didattica Statale IV Circolo Copyright © All rights reserved.
Failed to retrieve file