1. 24 Planning Information Proper installation of ducting is extremely important to ensure maximum performance Roof cap from any ventilation product e All CFMs are based on tests at 0 1 static pressure without applying static pressure CFM would be greatly overstated Straight runs and gradual turns are best for example each 90 elbow is equivalent to 5 10 feet 1 52 3 05 cm of straight run e Never use flexible duct it creates back pressure air turbulence and greatly reduces performance e Proper performance is dependent on proper ducting make sure that a qualified and trained installer is used Roof cap Check with a qualified and trained installer or local codes for makeup air requirement if any Max amp rating for hoods includes recommended ventilator kit rating all products must be hard wired direct with 2 wire with ground 300 or 600 CFM single blower interior power 7 round duct typical ductwork Duct cover or soffit Hood 1200 CFM single blower interior power 10 round duct typical ductwork Duct cover or soffit Plan where the duct work will be located Install proper sized duct work and roof or wall cap for the type of blower you are using Recommended hood locations for the most common installations are shown Adjust your measurements for various heights of ceilings soffits cabinets or ranges rangetops Hood
2. It is recommended that the 1 500 CFM ventilator be used with longer duct runs Max duct run is 75 ft 22 9 m a aie Ga reai buina dha toad ou tions Any combustible material used for this purpose must be covered with locally supplied stainless steel Viking also recommends using a backsplash NOTE Maximum amp rating for hoods includes recommended ventilator kit rating All products must be hard wired with 2 wire with ground An interior or exterior power ventilator kit must be purchased for installation with all 18 H hoods 12 13 Clearance Dimensions 15 VCWH Chimney Wall Hoods Dimensions amp Specifications VCWH Chimney Wall Hoods 30 36 42 48 54 amp 60 A Duct width 30 W 12 30 5 cm 36 W 12 30 5 cm 42 w 12 30 5 cm 48 W 18 45 7 cm 60 W 24 61 0 cm gt m 66 W 24 61 0 cm 6 2 N10 B Hood width 30 W 29 7 8 76 2 cm gel 36 W 35 7 8 91 1 cm 7 em 42 W 41 7 8 106 4 cm 48 W 47 7 8 121 6 cm y 60 W 59 7 8 152 1 cm bo 66 W 65 7 8 167 3 cm ba 2 aft 7 NOTE Optional duct cover sold separately VCWH Chimney Wall Hoods Description 30 36 42 48 60 Ductcoverdepth CBS cm Cd 12 30 5 cm to 24 61 0 cm 1200 1200 1200 1500 1500 Exteriorductsze 0000000000 10 25460 0000000000 O 5272 sa
3. 1 ENS A 4 1 NOTE Optional duct cover sold separately VWH 18 H Wall Hoods Description 30 36 42 48 60 75 9 cm 91 1 cm 106 4 cm 121 6 cm 152 1 cm 12 30 5 cm 12 30 5 cm 5 VINV300 VINV300 vinveoos vinv1200 vINV1200 600 1200 600 1200 1200 DEV900 DEV900 DEV900 DEV1200 DEV1200 1200 1200 1200 1500 1500 8 DIL1200 DIL1200 DIL1200 DIL1200 DIL1200 aca EA aa a FT 17 8 25 4 cm 17 8 25 4 cm 17 8 25 4 cm 25 4 cm 25 4 cm 42 52 82 2 5 2 8 2 8 0 5 3 8 0 5 3 8 0 5 3 7 8 8 5 7 8 8 5 A 1 200 CFM interior or exterior power ventilator should be used when installed over range rangetop with gas char grill Max duct run is 50 ft 15 2 m It is recommended that the 1 500 CFM ventilator be used with longer duct runs Max duct run is 75 ft 22 9 m NOTE Maximum amp rating for hoods includes recommended ventilator kit rating All products must be hard wired with 2 wire with ground An interior or exterior power ventilator kit must be purchased for installation with all 18 H hoods Exterior Ventilator Dimensions VWH 18 Wall Hoods Top View A B 30 W 14 15 16 37 9 cm 30 W 29 7 8 75 9 cm 36 W 17 15 16 45 6 cm 5 15 16 36 W 35 7 8 91 1 cm de 42 W 20 15 16 53 2 cm 15 1 cm 42 W 41 7 8 106 4 cm 4 48 W 23 15 16 60 8 cm 48 W 47 7 8 121 6 cm 60 W 29 15 16 76
4. 900 or 1200 CFM Exterior or In Line Ventilator Installation for all Chimney Island Hoods Top View 6 1 1 8 lt gt _ 2 9 cm 120 V A power 54 W 26 15 16 68 4 cm supply 66 W 32 15 16 83 7 cm 1 1 8 py 4 2 9 cm B a 54 W 53 7 8 136 8 cm 66 W 65 7 8 167 3 cm 54 W 18 45 7 cm 10 25 4 cm dia 66 W 24 61 0 cm duct location I lt gt 900 1200 or 1500 CFM Exterior or In Line Ventilator Installation for all Chimney Island Hoods 21 Interior Ventilator Dimensions VCIH Chimney Island Hoods Top View 12 1 1 8 30 5 cm 2 9 cm lt lt gt 120 V A 36 W 17 15 16 45 6 cm gt supply A gt power p 1 1 8 15 2cm 1 C gt o 2 9 cm 7 17 8 cm dia duct location 42 N 20 15 16 53 2 cm B 36 W 35 7 8 91 1 cm 42 41 7 8 106 4 cm B lt 600 CFM Interior Ventilator Installation for all Chimney Island Hoods Top View 6 1 1 8 gt 2 9 cm 120 V A power 54 W 26 15 16 68 4 cm supply 66 W 32 15 16 83 7 cm 1 1 8 c 2 9 cm B 54 W 53 7 8 136 8 cm 66 W 65 7 8 167 3 cm 10 25 4 cm dia duct location B gt 1200 CFM Interior Ventilator Installation for all Chimney Island Hoods 20 Dimensions 8 Specific
5. PROFESSIONAL Installation Guide Professional Indoor and Outdoor Hoods Viking Range LLC 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 845 4641 or visit the Viking Web site at vikingrange com 6 6 F21287A EN 071514 IMPORTANT Please Read and Follow AWARNING To reduce the risk of fire electric shock or injury to persons observe the following e Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel AWARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING 1 Installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flute chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guideline and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heatin
6. 10 Dimensions 8 Specifications Clearance Dimensions VWHO 18 H Outdoor Wall Hoods 36 48 amp 60 VWWHO 18 Outdoor Wall Hoods Seal joints with silicone Provided on T Series only A Hood width 36 W 35 7 8 91 1 cm 48 W 47 7 8 121 6 cm 60 W 59 7 8 152 1 cm NOTE Optional duct cover sold separately VWHO 18 H Outdoor Wall Hoods Description 36 48 60 Duct cover width 35 7 8 91 1 cm 47 7 8 121 6 cm 59 7 8 152 1 cm Duct cover depth Duct cover height Number of filters Interior ventilator kits VINV1200 VINV1200 VINV1200 Exterior ventilator kits DEV1200 1500 DEV1200 1500 DEV1200 1500 In line ventilator kits DIL1200 DIL1200 DIL1200 Interior duct size 10 25 4 cm Exterior duct size 10 25 4 cm Interior Maximum amps 11 8 Exterior Maximum amps 6 1 6 8 8 4 9 1 8 8 9 5 Note Outdoor Models must be installed in a covered non enclosed area and should be protected from the elements as much as possible A 1 200 CFM interior or exterior power ventilator should be used with all outdoor models and when indoor models e pee Sata i a cada Net eit abhi as rity are installed over range rangetop with gas char grill Max duct run is 50 ft 15 2 m 1 wee ee
7. H 12 H Wall Hoods w Standard Ventilator 30 amp 36 Dimensions amp Specifications Clearance Dimensions Interior Ventilator Dimensions VWH 18 H 24 Deep Wall Hoods 30 36 42 48 amp 60 Dimensions amp Specifications Clearance Dimensions Interior Ventilator Dimensions Exterior Ventilator Dimensions VWHO 18 H Outdoor Wall Hoods 36 48 8 60 Dimensions amp Specifications Clearance Dimensions VCWH Chimney Wall Hoods 30 36 42 48 amp 60 Dimensions amp Specifications Clearance Dimensions Interior Ventilator Dimensions Exterior Ventilator Dimensions VCIH Chimney Island Hoods 36 42 54 amp 66 Dimensions amp Specifications Clearance Dimensions Interior Ventilator Dimensions Exterior Ventilator Dimensions VBCV Wall Custom Ventilator System Dimensions amp Specifications Clearance Dimensions VBCV Ventilator Dimensions Planning Information Installation Procedures Installation VWH 12 H Wall Hoods w Standard Ventilator Duct Cover Option VWH 12 H Wall Hoods w Standard Ventilator Installation VWH 12 H Wall Hoods w Recirculating Kit Installation VWH 18 Wall amp VCWH Chimney Wall Hoods Duct Cover Option VWH 18 H Wall Hoods Duct Cover Option VCWH Chimney Wall Hoods Installation VCIH Island Hoods Service amp Registration Wiring Diagram Dimensions 8 Spe
8. 0 cm 60 W 59 7 8 152 1 cm 10 25 4 cm dia duct location 900 or 1200 CFM Exterior or In Line Ventilator Installation for all Top View A B 30 W 14 15 16 37 9 cm 30 W 29 7 8 75 9 cm 36 W 17 15 16 45 6 cm 5 15 16 36 35 7 8 91 1 cm 42 20 15 16 53 2 cm 15 1 cm o 42 41 7 8 106 4 cm 48 W 23 15 16 60 8 cm 48 W 47 7 8 121 6 cm 60 W 29 15 16 76 0 cm 60 W 59 7 8 152 1 cm 10 25 4 cm dia duct location 1200 or 1500 CFM Exterior or In Line Ventilator Installation for all Wall Hoods 11 Interior Ventilator Dimensions VWH 18 Wall Hoods B 30 W 29 7 8 75 9 cm 36 W 35 7 8 91 1 cm 42 W 41 7 8 106 4 cm 4 A 30 W 14 15 16 37 9 cm 36 W 17 15 16 45 6 cm 42 W 20 15 16 53 2 cm 48 47 7 8 121 6 cm 60 W 59 7 8 152 1 cm 48 W 23 15 16 60 8 cm 60 W 29 15 16 76 0 cm 7 17 8 cm dia duct location 300 or 600 CFM Interior Ventilator Installation for all Wall Hoods A B 30 W 14 15 16 37 9 cm 30 W 29 7 8 75 9 cm 36 W 17 15 16 45 6 cm 36 W 35 7 8 91 1 cm 42 20 15 16 53 2 cm 42 N 41 7 8 106 4 cm 48 W 23 15 16 60 8 cm 48 W 47 7 8 121 6 cm 60 W 29 15 16 76 0 cm 60 W 59 7 8 152 1 cm 10 25 4 cm dia duct location k gt 1200 CFM Interior Ventilator Installation for all Wall Hoods
9. 5 5 oO a O 5 4 ue O BES 0 9 o L CDs TF ess O ef C gt PMN O 5 Oo 5 o 5 N Zop lt ots 5 8 I cos 6 5 8 2 See 60 3 0 E Ye gt 0 2 5 oO amt gt 0 3 5 PE E O a oO gt 2 X 5 D 5 5 v 2 V a 5 2 0 2 3 1 me 0 2 az lt r oO me 2 0 32 0 6 Be 2 To PEINE 2 o I Y 8 o t gone 2 5 c E Ez Q S 5 5 5 re 0 0 E o CN 8 5 5 a gt 2358 2 5 z 55 5 2 Mo Se he 8 42 6 0 5 we v 5 7 6 w 0 0 6 5 O 2 8 4 Duct Cover Option ew chimney wall Hoods Measure distance from ceiling to canopy Tape to avoid scratching Place duct cover top inside duct cover base and lower until Slide the duct cover in place and fasten from inside desired height is found Mark height Use the retaining canopy using the sheet metal screws provided nuts and bolts to fasten in place and remove tape 35 Duct Cover Option ww 12 wall Hoods Measure distance from ceiling to canopy Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided To install ventillation kit refer to ventillation kit installation instructions 34
10. Installation VCIH Island Hoods Installation VCIH Island Hoods Zea SE Check framing where cutout will be Cut appropriate size hole in ceiling Either 7 or 10 NOTE 200 Ib limit depending on your specific unit and ventillator kit Run duct work down to bottom edge of duct Attach canopy to duct cover soffit Seal top of hood to cover soffit and secure in place Make sure the duct duct with aluminum tape does not stick down past the cover Mounting options Using duct cover with ceiling mounting bracket Option A VCIH only Using threaded rod for additional support Option B Attaching hood directly to soffit or duct cover Skip to step 3 Slide filter front over front lip Push filter rear up then Slide filter front over front lip Push filter rear up then slide back over rear lip slide back over rear lip To install ventillation kit refer to ventillation kit installation instructions Attach duct cover to ceiling The ceiling bracket can be Additional support option Drill holes in all four corners hidden by using a locally supplied trim for threaded rod and run rods from hood to ceiling 36 37 39 If service is required call your dealer or authorized service agency The name of the authorized service agency can be obtained from the dealer or distributor in your area Have the following information readily available e Model number e Serial number Date
11. purchased Name of dealer from whom purchased Clearly describe the problem that you are having If you are unable to obtain the name of an authorized service agency or if you continue to have service problems contact Viking Range LLC at1 888 845 4641 online at vikingrange com or write to VIKING RANGE LLC PREFERRED SERVICE 111 Front Street Greenwood Mississippi 38930 USA Record the information indicated below You will need it if service is ever required The model and serial number for your hood is located behind the baffle filter on the left side panel in the lower right corner Model no Serial no Date of purchase Date installed Dealer s name Address If service requires installation of parts use only authorized parts to ensure protection under the warranty THIS MANUAL SHOULD REMAIN WITH THE HOOD FOR FUTURE REFERENCE 38
12. 900 1200 or 1500 CFM exterior power typical ductwork Exterior blower 10 round duc Check Framing Duct cover or soffit Hood Wall Installation exterior power Wall cap typical ductwork Duct Duct cover or soffit Hood NOTE Because of the weight of the hood make sure NOTE Wall exhaust must be a minimum of 24 61 0 cm from ground This may vary depending on local codes that the mounting screws are driven into the framing and not just the drywall It may be necessary to drill additional holes in the canopy for proper alignment 27 Built In Wall Custom Ventilator System Dimensions vwecv Models 5 1 2 14 0 cm 10 25 4 cm dia duct location as Si 9 16 1 4 cm a 1200 or 1500 CFM Exterior or In Line Ventilator Installation 48 60 W Models 10 25 4 cm dia duct location e 1 4 cm 1200 CFM Interior Ventilator Installation 36 42 48 60 W Models Cc D 36 W 34 174 87 0 cm 367 W 17 178 43 5 cm 42 W 40 1 4 102 2 cm 42 W 20 1 8 51 1 cm 48 W 46 1 4 117 5 cm 48 W 23 1 8 58 7 cm 60 W 58 1 4 148 0 cm 60 W 29 1 8 74 0 cm 26 CAUTION If not using a duct cover using screws provided make sure top mounting screws are secured into soffit or cabinet framing Use additional mounti
13. ER including wet dishcloths or towels a violent steam explosion will result Use an extinguisher ONLY if e You know it is a Class ABC extinguisher and you already know how to operate it The fire is small and contained in the area where it started The fire department is being called You can fight the fire with your back to an exit il Interior Ventilator Dimensions VWH 10 H 12 H Wall Hoods w Standard Ventilator Top View A 23 7 8 60 6 cm 29 7 8 75 9 cm 35 7 8 91 1 cm B 5 1 4 13 3 cm 8 1 4 20 9 cm 11 1 4 28 6 cm 6 7 8 Electrical 11 15 16 30 3 cm hookup 14 15 16 37 9 cm 17 15 16 45 6 cm 7 17 8 cm dia duct location D 5 8 1 6 cm 3 5 8 9 2 cm 6 5 8 16 8 cm 460 CFM Interior Ventilator Installation Clearance Dimensions VWH 10 H 12 H Wall Hoods w Standard Ventilator NOTE When installing with a 24 high shelf the 27 68 6 cm max dimensions must be used Clearance Dimensions VWH 18 Wall Hoods Dimensions amp Specifications VWH 18 H 24 Deep Wall Hoods 30 36 42 48 amp 60 A Hood width KW 30 W 29 7 8 76 2 cm 36 W 35 7 8 91 1 cm Rg 42 41 7 8 106 4 cm S Sm 48 W 47 7 8 121 6 cm e 60 59 7 8 152 1 cm 6r
14. H Chimney Wall Hoods Top View 120V power 12 P supply 1 1 2 30 5 cm 3 8 cm lt ___ _ _ _ gt 2 Ix A 30 W 14 15 16 37 9 cm A 36 W 17 15 16 45 6 cm 1 1 2 42 W 20 15 16 53 2 cm 3 8 cm B 30 W 29 7 8 75 9 cm 36 W 35 7 8 91 1 cm 42 W 41 7 8 106 4 cm 7 17 8 cm dia duct location k gt 300 or 600 CFM Interior Ventilator Installation for 30 36 amp 42 models Top View 6 6 1 1 2 power lt gt 3 8 cm _ supply lt A gt gt gt y A 6 6 48 W 23 15 16 60 8 cm 15 2 cm A 18 45 7 cm 60 W 29 15 16 76 0 cm y 1 1 2 24 61 0 cm 66 W 32 15 16 83 7 cm 3 8 cm 24 61 0 cm B 48 W 47 7 8 121 6 cm 60 W 59 7 8 152 1 cm a 66 W 65 7 8 167 3 cm 10 25 4 cm dia duct location lt gt 1200 CFM Interior Ventilator Installation for 48 amp 60 models 16 Clearance Dimensions VCIH Chimney Island Hoods 19 Dimensions amp Specifications VCIH Chimney Island Hoods 36 42 54 amp 66 A Duct width 12 30 5 cm 12 30 5 cm 18 45 7 cm 24 70 0 cm Duct height 12 30 5 cm or 24 61 0 cm or 36 91 4 cm
15. Hood width 35 7 8 91 1 cm 41 7 8 106 4 cm 53 7 8 136 8 cm 65 7 8 167 3 cm NOTE Optional duct cover sold separately VCIH Chimney Island Hoods Description 36 42 54 66 12 30 5 om 12 30 5 om Ductcoverdepth o argo y O 12 30 5 cm or 24 61 0 cm or 36 91 4 cm PWimberoffiters Ys o a e e O DEV900 1200 DEV900 1200 1500 DEV1200 1500 DEV1200 1500 In line ventilator kits DIL1200 DIL1200 DIL1200 DIL1200 7 17 8 cm 7 17 8 cm 10 25 4 cm 10 25 4 cm 10 25A em gt 3 A 1 200 CFM interior or exterior power ventilator should be used when installed over range rangetop with gas char grill Max duct run is 50 ft 15 2 m It is recommended that the 1 500 CFM ventilator be used with longer duct runs Max duct run is 75 ft 22 9 m NOTE Maximum amp rating for hoods includes recommended ventilator kit rating All products must be hard wired with 2 wire with ground An interior or exterior power ventilator kit must be purchased for installation with all 18 H hoods 18 Exterior Ventilator Dimensions VCIH Chimney Island Hoods Top View 12 1 1 8 30 5 cm 2 9 cm lt gt 120 V A A a5 power 36 W 17 15 16 45 6 cm gt supply 42 N 20 15 16 53 2 cm 6 1 1 8 B 1526 1 9 2 9 cm 36 W 35 7 8 91 1 cm 42 41 7 8 106 4 cm 9 10 25 4 cm dia duct location lt gt
16. ations Clearance Dimensions VBCV Wall Custom Ventilator System 36 42 48 amp 60 Custom Hood Canopy Cutouts Wall Hoods Custom Hood Canopy Bottom Cutout Dimensions Description A Hood Width 33 7 16 84 9 cm 39 7 16 100 2 cm 45 7 16 115 4 cm 57 7 16 145 9 cm Make sure the back wall of the custom hood canopy is flush with the cutout so the ventilator system may be mounted as shown on page 25 For best 21 7 16 results center the unit over the 54 5 cm burners of the cooking product front to back right to left Custom Hood 54 5 cm Position ventilator system inside of the custom hood canopy and center it front to back and left to right Built In Ventilator System 3 OPTIONAL Rear mounting holes fasten ventilator system to rear of i custom hood canopy 2 Bottom mounting holes fasten ventilator system to bottom of custom hood canopy with the screws provided 22 23 Built In Wall Custom Ventilator System Dimensions vvecv Models 7 8 cm 2 2 cm lt m 21 7 8 gt 55 8 cm For 900 1200 or 1500 CFM Exterior For 300 600 or 1200 CFM Interior or In Line Ventilator Installation Ventilator Installation lt gt 9 16 1 4 cm gt gt 9 16 1 4 cm 900 or 1200 CFM Exterior 300 or 600 CFM Interior or In Line Ventilator Installation Ventilator Insta
17. cifications VWH 10 H 12 H Wall Hoods w Standard Ventilator 30 amp 36 A Hood width 30 W 29 7 8 76 2 cm 36 W 35 7 8 91 1 cm A Hood width 30 W 29 7 8 76 2 cm 36 W 35 7 8 91 1 cm NOTE Optional duct cover sold separately VWH 10 H 12 H Wall Hoods w Standard Ventilator Description 30 36 29 7 8 75 9 cm 35 7 8 91 1 cm N A 460 CFM Standard 7 17 8 cm Interior Maximum amps Disregard when using recirculating kits 460 CFM blower is shipped with hood Max duct run is 50 ft 15 2 m Read and Follow 46 For general ventilating use only Do not use to exhaust hazardous or explosive materials and vapors AWARNING TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS Rangehoods must be installed with the ventilators that are specified on 7 their carton indicating suitability with this model Other ventilators cannot be substituted AWARNING IMPORTANT Please To reduce the risk of injury to persons in the event of a rangetop grease fire observe the following Based on Kitchen Firesafety Tips published by NFPA SMOTHER FLAMES with a close fitted lid cookie sheet or metal tray then turn off the burner BE CAREFUL TO PREVENT BURNS If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT NEVER PICK UP A FLAMING PAN You may be burned DO NOT USE WAT
18. des 28 Installation VWH 10 H 12 H Wall Hoods w Recirculating Kit Attach with screws AWARNING To reduce the risk of fire electric shock or injury to persons observe the following e Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Flip hood over Insert 6 of electrical wiring through CAUTION Secure vent hood Make sure mounting the top of vent hood and secure Refer to local codes screws are secured into framing Use additional mounting screws and wall anchors if necessary 31 Duct Cover Option VWH 10 H 12 H Wall Hoods w Standard Ventilator Measure distance from ceiling to canopy Slide the duct cover in place and fasten from inside canopy using the sheet metal screws provided Installation VWH 12 H Wall Hoods w Recirculating Kit Remove damper and discard with transition Turn recirculating unit upside down Place vent hood upside down on recirculating unit 30 lip Push filter rear up then lip f ide back over rear Slide filter front over front slide back over rear vided wa TO O 0 I
19. g Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities When cutting of drilling into wall or ceiling do not damage electrical wiring and other hidden utilities Ducted fans must always be vented to the outdoors WARNING To reduce risk of fire use only metal ductwork CAUTION To reduce risk of fire and to properly exhaust air be sure to duct air outside Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages CAUTION To Reduce the Risk of Fire and Electric Shock Install this rangehood only with remote blower models manufactured by Viking model numbers DEV900 DEV1200 VEV900 VEV1200 OR DEV1500 VEV1500 or integral blowers manufactured by Viking model numbers DIV300 DIV440 DIV600 DIV800 DIV1200 VIV300 VIV600 or VIV1200 NOTE Please refer inside for specific canopy blower combinations NOTE If installing hood with warming shelf panel install warming shelf panel first IMPORTANT PLEASE READ AND FOLLOW Before beginning please read these instructions completely and carefully Do not remove permanently affixed labels warnings or plates from the product This may void the warranty Please observe all local and national codes and ordinances If no local codes are applicable wire in accordance with the National Electrical Code ANSI NFPA 70 latest edition Damp environment approved models should be insta
20. llation 36 42 W Models 36 42 W Models D 36 W 17 1 8 43 5 cm 42 W 20 1 8 51 1 cm 48 W 23 1 8 58 7 cm 60 W 29 1 8 74 0 cm 25 Clearance Dimensions VBCV Wall Custom Ventilator System VBCV Wall Custom Ventilator System Description 36 42 48 Number of filters 3 4 Reine 7 VINV300 VINV600 _ VINV1200 VINV1200 600 1200 1200 DEV900 DEv900 DEV1200 DEV1200 1200 1200 1500 1500 In line ventilator kits DIL1200 DIL900 1200 0 0 Interior duct size 7 10 7 10 10 10 17 8 25 4 cm 17 8 25 4 cm 25 4 cm 25 4 cm Exteriorductsze tons 4 2 5 2 In Line Maximum amps 5 3 7 2 5 3 7 2 96 100 A 1 200 CFM interior or exterior power ventilator should be used when installed over range rangetop with gas char grill Max duct run is 50 ft 15 2 m It is recommended that the 1 500 CFM ventilator be used with longer duct runs Max duct run is 75 ft 22 9 m NOTE Maximum amp rating for hoods includes recommended ventilator kit rating All products must be hard wired with 2 wire with ground An interior or exterior power ventilator kit must be purchased for installation with all 18 H hoods 6 aw ew ew j e 25 63 5 cm 25 63 5 cm 25 63 5 cm 31 78 7 cm 33 1 4 39 1 4 45 1 4 57 1 4 84 5 cm 99 75 cm 114 3 cm 144 8 cm 6 34 1 4 40 1 4 46 1 4 58 1 4 87 0 cm 102 2 cm 117 5 cm 148 0 cm
21. lled in a covered non enclosed area and should be protected from the elements as much as possible The installer should leave these instructions with the consumer who should retain for local inspector s use and for future reference Check with a qualified and trained installer or local codes for makeup air requirement if any This hood is for residential installation only and is not designed for installation over a commercial product Make sure power is off at the main circuit breaker or fuse box before making connections To avoid risk of fire electric shock or injury to persons turn off the electricity to the hood from the power supply before servicing or cleaning Viking hoods are equipped with variable speed control blowers These units will not function with a single speed ventilator All Viking Range ventilator kits are designed specifically for use with Viking Range hoods Use of any non Viking Range ventilator kit will void the hood warranty Viking hoods are equipped with the variable speed controls for blowers These units will not function with a single speed ventilator All Viking ventilator kits are designed specifically for use with Viking hoods Use of any non Viking ventilator kit will void the hood warranty READ AND SAVE THESE INSTRUCTIONS 10 11 12 13 14 15 16 17 18 19 20 21 22 24 25 27 28 30 30 33 34 35 36 38 39 Table of Contents Warnings amp Important Information VWH 10
22. na sanz 6 100 A 1 200 CFM interior or exterior power ventilator should be used when installed over range rangetop with gas char grill Max duct run is 50 ft 15 2 m It is recommended that the 1 500 CFM ventilator be used with longer duct runs Max duct run is 75 ft 22 9 m NOTE Maximum amp rating for hoods includes recommended ventilator kit rating All products must be hard wired with 2 wire with ground An interior or exterior power ventilator kit must be purchased for installation with all 18 H hoods 14 Exterior Ventilator Dimensions VCWH Chimney Wall Hoods Top View 120V 12 power 30 5 cm 1 1 2 supply lt gt 3 8 cm HA A 30 14 15 16 37 9 em 20 3 cm A 36 W 17 15 16 45 6 cm 1 1 2 42 W 20 15 16 53 2 cm 3 8 cm B 30 W 29 7 8 75 9 cm 36 W 35 7 8 91 1 cm 42 W 41 7 8 106 4 cm rA eee x 900 or 1200 CFM Exterior or In Line Ventilator Installation for 30 36 amp 42 models Top View 120 V 1 1 2 power A 48 W 23 15 16 60 8 cm 60 W 29 15 16 76 0 cm 66 32 15 16 83 7 cm B 48 W 47 7 8 121 6 cm 60 W 59 7 8 152 1 cm 66 W 65 7 8 167 3 cm 10 25 4 cm dia duct location 900 1200 or 1500 CFM Exterior or In Line Ventilator Installation for 48 amp 60 models 17 Interior Ventilator Dimensions VCW
23. ng screws if necessary Replace electrical box cover Make connection to breaker box Slide filter front over front lip Push filter rear up then slide back over rear lip 29 CAUTION Secure vent hood to wall using screws provided Use additional mounting screws and wall anchors if necessary BARE OR GREEN Connect black to black white to white and the green bare wire under the green screw NOTE Housing wiring must be properly installed for wiring to be correct when wiring unit Slide filter front over front lip Push filter rear up then slide back over rear lip Installation VWH 10 H 12 H Wall Hoods w Standard Ventilator Check damper for unrestricted movement adjust if Attach transition to damper Seal with aluminum tape necessary AWARNING To reduce the risk of fire electric shock or injury to persons observe the following e Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer Before servicing or cleaning unit switch power off at service panel and lock service panel to prevent power from being switched on accidentally When the service disconnecting means cannot be locked securely fasten a prominent warning device such as a tag to the service panel Insert 6 of electrical wiring through the top of vent hood Slide duct over transition and tape around joint and secure using wiring restrain Refer to local co