Home
Viking AF/AR User's Manual
Contents
1. Top View Top View Flush mount cabinet doors A mu 1 l Ar 2 5 cm 1 If standard 2 5 cm n Lae cabinet depth standard is used cabinet depth is used 3 4 1 9 cm Full End Panel 3 4 1 9 cm Full End Panel Cabinet Door 39 40 General Information Area Requirements Verify the following e Unit can fit into residence and can be moved around corners and through doorways e Floors can support unit s weight plus food weight approximately 1200 pounds 540 kg per unit e Rear wall is solid and is able to support two 2 horizontally mounted 2X4s included bolted to 2 wall studs The 2X4 board bolt heads must be flush with 2X4 to prevent obstruction e Remove anything attached to rear or side walls that can obstruct unit installation e Cutout dimensions are accurate e Electrical outlet is in correct location e Water line is in correct location e Do not install a refrigeration unit near a heat source nor in a location where the surrounding temperature will fall below 60 F le Electrical Requirements It is the customer s responsibility to e contact a qualified electrical installer e assure that the electrical installation is adequate and in conformance with the National Electrical Code ANSI NFPA 70 latest edition or Canadian Electrica
2. Anti Ti PD D IMENSIONS Designer All Refrigerator Freezer Dual 30 Designer Anti Tip Location One 2 x 4 Mounting Board Per Unit 1 1 2 3 8 cm x 3 1 2 8 9 cm Note If unit is installed deeper than 24 61 0 cm then shim behind the mounting boards by the difference Bottom of anti tip board is 3 7 8 9 8 cm below opening height Note Top of unit must be placed firmly under anti tip board Cutout Dimensions Designer All Refrigerator Freezer Anti Ti P Dim ensIons Designer All Refrigerator Freezer Dual 30 and 36 Designer Dual 30 and 36 Designer Electric Outlet Location Anti Tip Location Water Line Entry Area Note Cutout opening shown with All Freezer model on left Reverse water line entry if All Freezer model is on right o One 2 x 4 Mounting Board Per Unit 1 1 2 3 8 cm x 3 1 2 8 9 cm Note If unit is installed deeper than 24 61 0 cm then shim behind the mounting boards by the difference Bottom of anti tip board is 3 7 8 9 8 cm below opening height Note Top of unit must be placed firmly under anti tip board Note Dimensions shown for 36 AF AR model on the left Reverse mounting boards if units are installed on the right 35 36 Cuto ut D mens ons Designer All Refrigerator Freezer Anti Ti D men Si ONS Designer All Refrigerator Freezer Dual 36 Designer D
3. 61 0 cm then shim behind the mounting boards by the difference Bottom of anti tip board is 3 7 8 9 8 cm below opening height Note Top of unit must be placed firmly under anti tip board 19 20 Cabinet Information Professional Cabinet Information Professional Professional models fit semi flush in standard 24 61 0 cm deep cabinet openings The door Professional models fit semi flush in standard 24 61 0 cm deep cabinet openings The door face protrudes 2 1 2 6 4 cm from the cabinet face The handle protrudes an additional face protrudes 2 1 2 6 4 cm from the cabinet face The handle protrudes an additional 2 1 2 6 4 cm into the room 2 1 2 6 4 cm into the room Keg lens Top View A 1 13 16 A 4 6 cm 1 13 16 Space if 24 4 6 cm standard Space if 24 cabinet standard depth is cabinet used 24 depth is 61 0 cm used 24 3 4 eee 61 ae Cabinet Standar 1 9 cm 3 4 lt Full End Dept 1 9 cm ey Panel Full End P Countertop Partial Overlay Overhang Cabinet Door 2 1 2 6 4 cm Offset 6 4 cm Offset A 1 13 16 24 4 6 cm 61 0 cm Space if 24 Standard standard Cabinet cabinet Depth depth is used 3 4 1 9 cm Full End Panel 2 1 2 6 4 cm Offset
4. Viking Range Corporation 111 Front Street Greenwood Mississippi 38930 USA 662 455 1200 For product information call 1 888 VIKING1 845 4641 or visit the Viking Web site at vikingrange com UL c UL F20416A 071007J Viking Installation Guide All Retrigerator Freezer Table of Contents Warnings amp Important Information Professional Dimensions 30 and 36 Specifications 30 and 36 Cutout Dimensions 30 Anti Tip Dimensions 30 Cutout Dimensions 36 Anti Tip Dimensions 36 Dimensions Dual 30 Dimensions Dual 30 and 36 Dimensions Dual 36 Specifications Dual Cutout Dimensions Dual 30 Anti Tip Dimensions Dual 30 Cutout Dimensions Dual 30 and 36 Cutout Dimensions Dual 30 and 36 Cutout Dimensions Dual 36 Anti Tip Dimensions Dual 36 Cabinet Information Designer Dimensions 30 and 36 Specifications 30 and 36 Cutout Dimensions 30 Anti Tip 30 Cutout Dimensions 36 Anti Tip Dimensions 36 Dimensions Dual 30 Dimensions Dual 30 and 36 Dimensions Dual 36 Specifications Dual Cutout Dimensions Dual 30 Anti Tip Dimensions Dual 30 Cutout
5. 2 7 8 Approximate Shipping Weight 425 Ibs 193 2 kg ats cm 13 4 m in n emi 27 1 A x 417164 T gt 692 A135 em 36 All Refrigerator Freezer Description VCFB364 VCRB364 82 778 Overall Height from Bottom Min 82 3 4 210 2 cm to Max 84 1 16 213 5 cm 75 45 N cm Overall Depth from Rear To front edge of side trim 22 3 16 56 4 cm 192 3 16 ja ae To front of top grille 24 11 16 62 7 cm Sin DO Hi ghee BA 1 16 To front of handle endcap 27 1 4 69 2 cm 69 ae cm Cutout Width 35 1 2 90 2 cm ax Cutout Height Min 82 7 8 210 5 cm to Max 84 1 16 213 5 cm Cutout Depth Min 24 61 0 cm Electrical Requirements 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum Amp Usage 9 9 amps Inlet Water 1 4 copper tubing inlet Requirements waterline minimum 20 psi o maximum 120 psi 5 v Overall Interior Dimensions A m Total Capacity 19 1 cu ft 541 liters 22 8 cu ft 646 liters A pele Approximate Shipping Weight 500 Ibs 227 3 kg fu a i 25A ail I 1 o Cuto ut D mens ons Professional All Refrigerator Freezer Anti Ti D men S ons Professional All Refrigerator Freezer 30 Professional 30 Professional Electric Outlet Location l Anti Tip Location
6. 15 16 Cuto ut D IMENSIONS Professional All Refrigerator Freezer Anti Ti PD D IMENSIONS Professional All Refrigerator Freezer Dual 30 and 36 Professional Dual 30 and 36 Professional Electric Outlet Location Anti Tip Location Water Line Entry Area Note Cutout opening shown with All Freezer model on left Reverse water line entry if All Freezer model is on right we Two 2 x 4 Mounting Boards Per Unit 3 7 6 cm x 3 1 2 8 9 cm Note If unit is installed deeper than 24 61 0 cm then shim behind the mounting boards by the difference Bottom of anti tip board is 3 7 8 9 8 cm below opening height Note Top of unit must be placed firmly under anti tip board Note Dimensions shown for 36 AF AR model on the left Reverse mounting boards if units are installed on the right 17 18 Cuto ut D mens ons Professional All Refrigerator Freezer Anti Ti D men S ons Professional All Refrigerator Freezer Dual 36 Professional Dual 36 Professional Electric Outlet Location Anti Tip Location Water Line Entry Area Note Cutout opening shown with All Freezer model on left Reverse water line entry if All Freezer model is on right o Two 2 x 4 Mounting Boards Per Unit ooo 3 7 6 cm x 3 1 2 8 9 cm Note If unit is installed deeper than 24
7. Do not locate shut off valve behind the unit e The installation of Viking units with a reverse osmosis system is acceptable as long as the water pressure remains within the allowable PSI as stated below It is important to note that with many reverse osmosis systems the pressure starts off high but then it decreases as the water level of the reverse osmosis storage area drops This must be considered when checking the water pressure coming into the unit Connect a vertical or horizontal 1 2 1 2 cm to 1 1 4 3 2 cm COLD water line near water area Run water line through the floor back or side wall Tubing should lay flat on floor underneath the unit Clamp tubing to wall or floor Water pressure must be greater than 20 psi and less than 120 psi on non dispensers and greater than 35 psi and less than 120 psi on dispensers General Information e Most of the unit s weight is at the top Extra care is needed when moving the unit to prevent tipping e Do Not remove protective film until unit is in operating position e All four leveling legs must contact the floor to support and stabilize the full weight e Do not drop unit e Remove exterior shipping materials prior to moving unit into home e Use two or more people to move and install unit Failure to follow this instruction can result in back or other injury e To avoid personal injury wear gloves when performing any installation procedure and wear
8. L Water Line Entry Area Note Shown for All Freezer Only Two 2 x 4 Mounting Boards 3 7 6 cm x 3 1 2 8 9 cm Note If unit is installed deeper than 24 61 0 cm then shim behind the mounting boards by the difference Bottom of anti tip board is 3 7 8 9 8 cm below opening height Note Top of unit must be placed firmly under anti tip board Cuto ut D mens ons Professional All Refrigerator Freezer Anti Ti D men S ons Professional All Refrigerator Freezer 36 Professional 36 Professional Electric Outlet Location Anti Tip Location Water Line Entry Area Note Shown for All Freezer Only Two 2 x 4 Mounting Boards Lee 3 7 6 cm x 3 1 2 8 9 cm Note If unit is installed deeper than 24 61 0 cm then shim o behind the mounting boards by the difference Bottom of anti tip board is 3 7 8 9 8 cm below opening height Note Top of unit must be placed firmly under anti tip board D IMENSIONS Professional All Refrigerator Freezer Dual 30 Professional D IMENSIONS Professional All Refrigerator Freezer Dual 30 and 36 Professional oe 30 ae N 29 3 19 32 ee ane a Gie 4 Tie a A a C4 9 5 3 1 L
9. 21 22 D IMENSIONS Designer All Refrigerator Freezer 30 Designer 29 754 A935 16 a 271 o aalt 2395 g ee a f o b 23 36 Designer 35 9 5 3 n 23 3 ak Specifications Designer All Refrigerator Freezer 30 All Refrigerator Freezer Overall Width DDFB304 30 76 2 cm DDRB304 Overall Height from Bottom Overall Depth from Rear Min 82 3 4 210 2 cm to Max 84 1 16 213 5 cm To front edge of side trim To front of top grille To front of handle 23 13 16 60 5 cm 24 61 0 cm 26 66 0 cm Cutout Width 30 76 2 cm Cutout Height Min 82 7 8 210 5 cm to Max 84 1 16 213 5 cm Cutout Depth Min 24 61 0 cm Electrical Requirements 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum Amp Usage 9 9 amps Inlet Water Requirements 1 4 copper tubing inlet waterline minimum 20 psi maximum 120 psi N A Overall Interior Dimensions Total Capacity 15 9 cu ft 450 liters 18 2 cu ft 516 liters Approximate Shipping Weight 36 All Refrigerator Freezer Overall Width 425 lbs 193 2 kg DDFB364 36 91 5 cm DDRB364 Overall Height from Bottom Min 82 3 4 210 2 cm to Max 84 1 16 213 5 cm Overall Depth from Rear To
10. the refrigerator system but all other functions are normal These include lights and control See picture below for visual indication of Showroom Mode COLDEST FRZ HIGH MAX MAX TEMP TEMP REF FRZ DOOR OPEN To exit Showroom Mode B Press amp Hold Display On or Activate Controls while holding press and hold Higher Temp and Alarm Off together The control will beep 3 times to alert the user that Showroom Mode has been exited 4 Press Max Frz amp Display Off at the same time and hold until beeps force start compressor 5 All models need to be set at the 5th bar for Refrigerator amp Freezer factory setting 51 Service amp Registration Service amp Parts Only authorized replacement parts may be used in performing service on the appliance Do not repair or replace any part of the appliance unless specifically recommended in the manual All other servicing should be referred to a qualified technician Record the following information indicated below You will need it if service is ever required The serial number and model number for your appliance are located on the identification plate mounted behind the top light Model Number Serial Number Date of Purchase Date Installed Dealer s Name Address 52
11. 25 26 Cutout Dimensions Designer All Refrigerator Freezer Anti Tip Dimensions Designer All Refrigerator Freezer 36 Designer 36 Designer Electric Outlet Location gt i Anti Tip Location Se _ Water Line Entry Area Note Shown for All Freezer Only One 2 x 4 Mounting Board 1 1 2 3 8 cm x 3 1 2 8 9 cm Note If unit is installed deeper than 24 61 0 cm then shim behind the mounting boards by the difference Bottom of anti tip board is 3 7 8 9 8 cm below opening height Note Top of unit must be placed firmly under anti tip board 27 28 Dimensions Designer All Refrigerator Freezer Dimensions Designer All Refrigerator Freezer Dual 30 Designer Dual 30 and 36 Designer Pea T 9 535 9 5 9 Boe 23 3 cm See SS 82_ n 82 7 n ioe arose Min i Min to 0 84_ 841 465 213 16 2135 6 S cm cm Max Max D IMENSIONS Designer All Refrigerator Freezer Dual 36 Designer i Colt 3 1 TEA a oo 8 9 bal A m A 2 5 3 n 23 3 s oe 75 ee 82 7 n 21050 Min to 84q_ 21gig 16 Max Sy N 31 Specifications Designer All Refrigerator Freezer Dual All Refrigerator Freezer 2 30 Units 1 36 amp 1 30 U
12. Dimensions Dual 30 and 36 Anti Tip Dimensions Dual 30 and 36 Cutout Dimensions Dual 36 Anti Tip Dimensions Dual 36 Cabinet Information General Information Unpacking amp Moving Installation Hinge Adjustment Kickplate Installation Door Stop Adjustment Final Installation Performance Checklist Control Panels Service amp Registration IMPORTANT Please Read and Follow Make sure that incoming voltage is the same as unit rating An electric rating plate specifying voltage frequency wattage amperage and phase is attached to the product To reduce the risk of fire electric shock or injury to persons installation work and electrical wiring must be done by qualified people in accordance with all applicable codes and standards including fire rated construction The installer should leave these instructions with the consumer who should retain them for local inspector s use and for future reference It is your responsibility to Comply with installation specifications and dimensions Properly install unit Remove any moldings or decorative panels that prevent the unit from being serviced Make sure that you have these materials not provided with your unit which are necessary for proper installation 1 4 6 mm copper tubing with shutoff valve e6 8 x 3 7 6 cm wood screws longer screws may be required e1 Sadd
13. e 2u 23 3 cm Es a es P le 75 1 5 192 XY 16r Ae cm 82 7 gu 21 0 5 cm Min to A n 21 16 U 41 4 3 5 ze Max ey TR 2em y 29_ 74 Van pags 3 4 Cr 20 1 om 62 m Bel x 2 x of ERVA cm 6 16 2 02 0 29 7 30 pa 35 3 19 39n Se 36 io ee 9 1 cm 4 De O O non 9 5 3 gt 2 23 3 chy CF leas ala 75 i cm 82 7 n 8 210 5 cm Min to 84 17 a Chee 27 1 4 ne cm Sy D IMENSIONS Professional All Refrigerator Freezer Specifi cati ONS Professional All Refrigerator Freezer Dual 36 Professional 35 88 ect 88 en 35 319 390 O15 em 938 oa 9 1 cm n 91 5 cm se Daa 9 5 n r 23 as 75 4 192 28 16 em 22 8 ne cm ae D Vis 5 97 1 4 13 5 cm ri sae 13 Overall Width Dual All Refrigerator Freezer 2 30 Units 1 36 amp 1 30 Unit 2 36 Units 60 152 4 cm 66 167 6 cm 72 182 9 cm Overall Height from Bottom Overall Depth from Rear Min 82 3 4 210 2 cm to Max 84 1 16 213 5 cm To front edge of side trim 22 3 16 56 4 cm To front of top grille 24 11 16 62 7 cm To front of handle endcap 27 1 4 69 2 cm Cutout Width 59 1 2 151 1 cm 65 1 2 166 4 cm 71 1 2 181 6 cm Cutout Height Min 82 7 8 210 5 cm to Max 84 1 16 213 5 c
14. ect water supply if applicable e Verify icemaker fill tube is properly inserted e Verify icemaker bailarm is down e Verify dispenser operation if applicable 50 O Align square door s O Verify drain pan is properly installed and there are no leaks in water connection O Install kickplate Remove internal packaging and labels and wipe unit down Installer s information Installers Name Installers Company Date Verity Operations Control Panels All Refrigerator FRZ ACTIVATE REF HIGHER LOWER HIDDEN HIDDEN MAX ALARM DISPLAY CONTROLS TEMP TEMP TEMP BUTTON TON REF OFF OFF All Freezer ACTIVATE FRZ HIGHER LOWER HIDDEN HIDDEN MAX ALARM DISPLAY CONTROLS TEMP TEMP TEMP BUTTON MAN REE FRZ OFF OFF 1 Press Display On or Activate Controls pad 2 Verify unit is not in Sabbath Mode If in Sabbath Mode A The Sabbath Mode will disable the interior lights display except 3 blue squares and alarm See picture below for visual indication of Sabbath Mode COLDEST FRZ HIGH MAX MAX TEMP TEMP REF FRZ DOOR OPEN To exit the Sabbath Mode B Press amp Hold Display On or Activate Controls and then Display Off for 3 seconds The control will beep 3 times to alert the user the Sabbath Mode has been exited 3 Verify unit is not in Showroom Mode If in Showroom Mode A The Showroom Mode will disable
15. enter grille louver up and pull out Using an 8 magnetic nut driver remove the two 1 4 screws Hinge Adjustment A Plug in power cord to verify operation Place unit within 3 of being flush with cabinets Loosen the four hinge screws Adjust door 3 Note Make sure power switch and showroom switch Note To avoid cabinet damage place cardboard Retighten four hinge screws PNR A are in the On Position between cabinets and unit When moving unit do not crimp kink or crush water supply line Carefully move unit until semi flush with cabinet Pull supply tubing forward under unit depending on unit Note DO NOT use plastic water lines 7 of DE KS OF Refrigerator Refrigerator Attach one 2x4 to wall stud refer to dimensions page If needed depending on cabinet and depth Flush water line by running two quarts of water Connect supply tube to water valve using for exact location attach second 2x4 to first 2x4 into a bucket Turn water off a 1 2 wrench Note DO NOT overtighten 45 46 Door Stop Adjustment or ae Y TN a Open refrigerator door so door stop and shoulder screw are accessible Lif
16. eye protection when cutting metal straps Moving Unit Remove shipping brackets from skid by removing 4 bolts 2 on each side with a 1 2 deep well socket wench and a pair of pliers Note Tilting unit is not required to remove shipping brackets TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed Keep doors closed until appliance is completely installed and secured per installation instructions Use two or more people to move and install appliance Failure to do so can result in death or serious injury Unpacking unit 1 Remove top and bottom strap 2 Remove top cap 3 Cut carton rear approximately 1 4 0 6 cm to 1 2 5 cm from right corner with a utility knife extended 1 4 0 6 cm 4 Remove carton and exterior packaging Save cardboard shipping material to protect floor surface when installing unit Remove anti tip board kickplate and door trim pieces DF models from rear of unit Slip appliance dolly between unit and skid Remove unit from skid Note Use excess packaging to protect decorative trim also verify that leveling legs are up 0 adjustment Installation Place unit in front of cutout Designer Pull the center grille louver up at an angle and pull out Remove grille assembly Professional Lift c
17. front edge of side trim 23 To front of top grille To front of handle 13 16 60 5 cm 24 61 0 cm 26 66 0 cm Cutout Width 36 91 5 cm Cutout Height Min 82 7 8 210 5 cm to Max 84 1 16 213 5 cm Cutout Depth Min 24 61 0 cm Electrical Requirements 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum Amp Usage 9 9 amps Inlet Water Requirements 1 4 copper tubing inlet waterline minimum 20 psi maximum 120 psi N A Overall Interior Dimensions Total Capacity 19 1 cu ft 541 liters 22 8 cu ft 646 liters Approximate Shipping Weight 500 Ibs 227 3 kg 24 Cuto ut D mens ons Designer All Refrigerator Freezer Anti Ti D men Si ons Designer All Refrigerator Freezer 30 Designer 30 Designer Electric Outlet location ea i oo ee a eee Anti Tip Location 1 7 6 cm 5 Ot i 8 4 cm Water Line Entry Area Note Shown for All Freezer Only Son One 2 x 4 Mounting Board ae 1 1 2 3 8 cm x 3 1 2 8 9 cm ae Note If unit is installed deeper than 24 61 0 cm then shim o behind the mounting boards by the difference Bottom of anti tip board is 3 7 8 9 8 cm below opening height Note Top of unit must be placed firmly under anti tip board
18. l Code C22 1 1998 and C22 2 No 0 M91 or latest edition and all local codes and ordinances A 115 volt 60 Hz 15 amp fused electrical supply is required It is required that a separate circuit serving only this appliance be provided This appliance is equipped with a power supply cord having a 3 prong grounding plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong grounding type wall receptacle Do not use an extension cord If codes permit a separate grounding wire to be used it is recommended that a qualified electrician determine that the grounding path is adequate DO NOT ground to a gas pipe Check with a qualified electrician if you are not sure the appliance is properly grounded DO NOT have a fuse in the neutral or grounding circuit Anti Tip Requirements The anti tip boards should be fastened into position prior to moving the unit into the opening Note Additional mounting boards may be required if the unit does not touch the back wall of the enclosure To prevent unit from tipping forward it must be secured in place with a solid soffit or wood block General Information AWARNING To avoid serious illness or death do not use unit where water is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts The contaminan
19. le valve do not use self piercing feature of the valve Assure that floor will support unit door panels and contents approximately 1200 pounds 540 kgl Provide a properly grounded electrical outlet Assure that location will permit appliance doors to open 90 minimum AWARNING ELECTRICAL SHOCK HAZARD Disconnect power or turn Wy power disconnect switch to OFF position before removing ew top grille Failure to do so can result in death or electrical shock Your safety and the safety of others is very important We have provided many important safety messages in this manual and on your appliance Always read and obey all satety messages This is the safety alert symbol This symbol alerts you to hazards that can kill or hurt you and others All safety messages will be preceded by the safety alert symbol and the word DANGER or WARNING These words mean A DANGER You will be killed or seriously injured if you don t follow instructions AWARNING You can be killed or seriously injured if you don t follow instructions All safety messages will identify the hazard tell you how to reduce the chance of injury and tell you what can happen if the instructions are not followed AWARNING TIP OVER HAZARD Appliance is top heavy and tips easily when not completely installed Keep doors closed until appliance is completely installed and secured per installation instructions Use two or mo
20. m Cutout Depth Min 24 61 0 cm Electrical Requirements 2 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum Amp Usage 9 9 amps per unit Inlet Water Requirements All Freezer Only 1 4 copper tubing inlet waterline minimum 20 psi maximum 120 psi Overall Interior Dimensions 30 Freezer 30 Refrigerator 36 Freezer 36 Refrigerator 15 9 cu ft 450 liters 18 2 cu ft 516 liters 19 1 cu ft 541 liters 22 8 cu ft 646 liters Approximate Shipping Weight 30 Freezer or Refrigerator 425 Ibs 193 2 kg 36 Freezer or Refrigerator 500 Ibs 227 3 kg Cutout D IMENSIONS Professional All Refrigerator Freezer Anti Ti PD D IMENSIONS Professional All Refrigerator Freezer Dual 30 Professional Dual 30 Professional Electric Outlet Location Anti Tip Location Water Line Entry Area Note Cutout opening shown with All Freezer model on left Reverse water line entry if All Freezer model is on right N Two 2 x 4 Mounting Boards Per Unit ao 3 7 6 cm x 3 1 2 8 9 cm Note If unit is installed deeper than 24 61 0 cm then shim behind the anti tip bracket by the difference Bottom of anti tip board is 3 7 8 9 8 cm below opening height Note Top of unit must be placed firmly under anti tip board
21. nit 2 36 Units Overall Width 60 152 4 cm 66 167 6 cm 72 182 9 cm Overall Height from Bottom Min 82 3 4 210 2 cm to Max 84 1 16 213 5 cm Overall Depth from Rear To front edge of side trim 23 13 16 60 5 cm To front of top grille 24 61 0 cm To front of handle 26 66 0 cm Cutout Width 60 152 4 cm 66 167 6 cm 72 182 9 cm Cutout Height Min 82 7 8 210 5 cm to Max 84 1 16 213 5 cm Cutout Depth Min 24 61 0 cm Electrical Requirements 2 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with grounded 3 prong plug attached to product Maximum Amp Usage 9 9 amps per unit Inlet Water Requirements 1 4 copper tubing inlet waterline minimum 20 psi All Freezer Only maximum 120 psi Overall Interior Dimensions 30 Freezer 15 9 cu ft 450 liters 30 Refrigerator 18 2 cu ft 516 liters 36 Freezer 19 1 cu ft 541 liters 36 Refrigerator 22 8 cu ft 646 liters Approximate Shipping Weight 30 Freezer or Refrigerator 425 Ibs 193 2 kg 36 Freezer or Refrigerator 500 Ibs 227 3 kg 32 Cutout Dimensions Designer All Refrigerator Freezer 24 Eor Dual 30 Designer Electric Outlet Location Water Line Entry Area Note Cutout opening shown with All Freezer model on left Reverse water line entry if All Freezer model is on right Il I
22. re people to move and install appliance Failure to do so can result in death or serious injury Most of the unit s weight is at the top Extra care is needed when moving the unit to prevent tipping Use cardboard shipping material or plywood under unit until it is installed in the operating position to protect floor surface D IMENSIONS Professional All Refrigerator Freezer 30 Professional Specifications Professional All Refrigerator Freezer 30 All Refrigerator Freezer Overall Width VCFB304 30 76 2 cm VCRB304 Overall Height from Bottom Min 82 3 4 210 2 cm to Max 84 1 16 213 5 cm 3 19 39n 76 Overall Depth from Rear To front edge of side trim 22 3 16 56 4 cm 9 1 cm S Ions e a 7 To front of top grille 24 TIS 62 7 cm fil 36 Professional To front of handle endcap 27 1 4 69 2 cm LU I S Zon Cutout Width 29 1 2 74 9 cm 23 3 cm Cutout Height Min 82 7 8 210 5 cm to Max 84 1 16 213 5 cm Y 35 Cutout Depth Min 24 61 0 cm 4 88 9 cm Electrical Requirements 115 volt 60 Hz 15 amp dedicated circuit 3 wire cord with 319 350 a i grounded 3 prong plug attached to product 94 cm E cm Maximum Amp Usage z 9 9 amps l M nn Tas Inlet Water 1 4 copper tubing inlet A Requirements waterline minimum 20 psi N A L 5 32 maximum 120 psi 23 3 Cm Overall Interior Dimensions oD ie Total Capacity 15 9 cu ft 450 liters 18 2 cu ft 516 liters
23. t unit off rollers to desired height and level unit using a 5 16 head wrench Note DO NOT use an electric device Overtightening can cause damage Final Installation Refrigerator Attach positive secure self tapping bolts to 2x4 using a 22 extension Verify that drain pan is installed and aligned Replace top air grille Kickplate Installation Professional Replace the center grille louver Align holes on both ends of louvered panels and insert screws Using a Phillips screwdriver attach the kickplate to the unit and adjust to desired height 47 Note Shoulder screw should be in 110 door opening position Remove shoulder screw and place in 90 or 120 position Using an 8 magnetic nut driver replace the two 1 4 screws Designer Replace the center grille louver Open door Display should flash 49 Press ACTIVATE CONTROLS button pad and close door Note There is a 6 minute delay before the unit starts Performance Checklist C Verify cabinet size Verify electrical supply and water supply if applicable Install anti tip device s and verify unit is secure _ Position unit in cutout level at desired height and secure unit _ Plug in unit and verify operation Conn
24. ts or other substances removed or reduced by this water treatment system are not necessarily in you water Water Supply Requirements Use only 1 4 6 mm copper tubing for water line Do Not install copper tubing in area where temperatures drop below 35 F 1 7 C Before attaching copper tubing to the unit flush at least 2 quarts 1 9 L of water through the copper tubing and into a bucket to remove any particles in the water line e Viking Range Corporation is not responsible for property damage due to improper installation or water connection e Connect 1 4 6mm flexible copper tubing to household plumbing in compliance with local codes and ordinances e Length of copper tubing must reach from water supply connection to the unit connection with an additional length to facilitate moving the unit out of enclosure for cleaning or service Tubing should be soft instead of rigid and ends should be free of burrs e Copper tubing route must be above 35 F 1 7 C to prevent water line from freezing 42 e Do not use plastic water lines from the household plumbing to the water inlet valve connection on the refrigeration unit e Do not use the self piercing feature of a saddle valve The hole made by the piercing lance is too small for the water flow rate required by the ice maker e If saddle valve is not used place a separate shut off valve in an easily accessible location between water supply and the unit
25. ual 36 Designer Electric Outlet Location Anti Tip Location Aa i l i Water Line Entry Area i Note Cutout opening shown with All Freezer model on left Reverse water line entry if All Freezer model is on right SW S One 2 x 4 Mounting Board Per Unit oo 1 1 2 3 8 cm x 3 1 2 8 9 cm Note If unit is installed deeper than 24 61 0 cm then shim behind the mounting boards by the difference Bottom of anti tip board is 3 7 8 9 8 cm below opening height Note Top of unit must be placed firmly under anti tip board 37 38 Cabinet Information cesignen Cabinet Information cesignen Designer models fit flush in standard 24 61 0 cm deep cabinet openings with no protrusion into the Designer models fit flush in standard 24 61 0 cm deep cabinet openings with no protrusion into the room except 2 5 1 cm curved handle depth room except 2 5 1 cm curved handle depth Top View 2m Overlapping cabinet doors A 5N 1 rl 2 5 cm a If standard 1 25 63 5 cm 2 5 cm standard If standard cabinet depth 25 63 5 cm is used standard cabinet depth 3 4 is used Depth 24 1 9 cm 61 0 cm Full End n Standar Panel 3 4 Cabinet 1 9 cm Depth Full End P Panel Cabinet Door
Download Pdf Manuals
Related Search
Related Contents
Screen and Button Descriptions Brodit ProClip 512371 CHECKTHERM CONTRACT DOCUMENT - City of Cape Town PGT-10-S Configuring the 3512 Samsung RC-A300 User Manual HAL MSIU Software User Manual GeoWave Documentation AQVSL-AQVSH STAR Copyright © All rights reserved.
Failed to retrieve file