Home

Utica Boilers SSV Brochure

image

Contents

1. Ans SSV Series There are some things you can always depend on _ _ i F F T 1 Se F l x ii r x SSV Series aG TI Gas Fired Wall Hung Modulating Condensing Boiler 015 ENERGY STAR www energystar gov 95 AFUE e 5 1 Turn Down Ratio e SSV Vertical Heat Exchanger Patent Pending Low Maintenance Self Cleaning Designed in the U S for the U S 150 psi MAWP e Approved for PVC CPVC and Polypropylene venting e 15 Year Limited Warranty plus an industry leading first year 500 Heat Exchanger Labor Warranty AAW i lt Y Be Bos There are some things you can always depend on www uticaboilers com UTICA BOILERS Original The heat exchanger is the critical component of any boiler and is primarily responsible for efficiency and durability At the heart of the 95 efficient SSV is the Utica family s unique vertically mounted helical fin tube heat exchanger made of 316L 444 stainless steel The fins are laser welded onto the stainless tube resulting in greater strength and heat transfer capabilities Economical The Utica SSV is 95 AFUE Annual Fuel Utilization Efficiency and has been awarded Energy Star Most Efficient status The SSV s advanced control automatically regulates boiler operation to ensure you are using the least amount of fuel possible The SSV s control adjusts both the amount of gas being burned modulation as well
2. as the boiler water temperature outdoor reset Gas burner modulation reduces your fuel cost by adjusting the fuel burned to meet the actual demands of your heating system Rarely will your home require the full capacity of the SSV and burning more gas than needed is bad for your budget and the environment Outdoor Temperature Reset adjusts the boiler water temperature based on outdoor conditions During cold periods water temperature is increased As it gets warmer water temperature is lowered Varying the water temperature reduces your fuel costs Dependable Utica s Stainless Steel Heat Exchanger e ASME certified to operate in applications up to 150 psi though the typical residential application is around 15 psi e Every heat exchanger is tested up to 375 psi this is 25 times the typical residential boiler system operating pressure e Proven reliability with tens of thousands of successful U S boiler installations Utica Quality e Every boiler is test fired at the factory e Complete combustion test is performed and a computer printout of the results are shipped with every boiler to ensure proper commissioning 15 year Limited Manufacturer s Warranty The SSV heat exchanger is simply the finest ever designed and as such we provide the strongest factory warranty available An additional first year leak free heat exchanger coverage provides the original purchaser the right to select a new replacement SSV boiler or heat exch
3. anger at their choice and receive a labor allowance of 500 00 for the servicing contractor Individual savings may vary SSV Series Competition Competition vs SSV Coil The SSV offers a round shape and a larger diameter coil for better water flow and reduced scaling Other manufacturers use heat exchangers that are more prone to this build up They position the heat exchanger horizontally and use smaller diameter tubing both of which result in sediment buildup and ongoing maintenance costs to keep them clean SSV Coil SSV Coil The vertically positioned SSV heat exchanger coil drains away any debris and scale and in doing so is self cleaning The increased efficiency of the Utica SSV could save up to 40 on heating bills annually The 95 AFUE efficiency of the Utica SSV allows it to qualify for State Federal and local Utility company rebates The average water heater is rated at 59 EF Energy Factor measure of the useful energy coming out of your water heater divided by the amount of energy consumed to heat domestic water The typical water heater accounts for 18 of your fuel bill One of the conveniences of heating with a boiler is the ability to use it to generate your domestic hot water By pairing your 95 efficient SSV with an H2O indirect water heater tank you will reduce your fuel consumption for heating hot water increase the amount of hot water available and be protected with a lifetime tan
4. et LO O Dimensions Water Content Width A Height B Bracket D Ht w Piping 30 75 40 75 All ratings and specifications subject to change UTICA BOILERS Standard Equipment 6 Certifications P O Box 4729 Utica New York 13504 0 7 1000 Btu hr British Thermal Units Per Hour 2 Heating Capacity and AFUE Annual Fuel Utilization Efficiency are based on DOE Department of Energy test procedures Boiler Input Rate Net AHRI Rating Water MBH Heating Capacity MBH MBH a AFUE a E 12 92 om 0 0 cm See Local Code Schedule 40 PVC can 05m Bottom Required Right Side 0 0 cm Oem Oem Pem em Combustion 6 16 cm Hot Water Piping 6 16 cm 6 Ft 1 8 m 100 Ft 30 5 m Note Refer to IOM and vent pipe manufacturer s instructions for equivalent vent lengths and alternate venting materials 1 2 NPT 3 4 NPT Condensate Drain 3 4 NPT 3 4 NPT Return Supply Water 3 4 Copper stub 1 Copper stub 120 Volts AC 60hertz 1 phase Less than 12 amps 15 amp circuit recommended Natural Gas Min 3 0 w c 0 7 kPa Max 13 5 w c 3 3 kPa Propane Min 5 0 w c 1 2 kPa Max 13 5 w c 3 4 kPa 050 075 100 1 1 Gallons 150 200 1 8 Gallons Wall Mounted Bracket included Boiler Control Module Automatic Low Vol
5. k warranty Ask your heating contractor to replace your inefficient standalone hot water tank with an H2O Visit our website at www uticaboilers com for rebate information and qualification details These valuable rebates help offset the installation costs The SSV is an original economical dependable approach UTICA 9 i ij yates to residential heat and domestic hot water I SSV Series Key Features H2O O Indirect Water Heater Gas Supply e All 316 L Stainless e Equipped with T amp P e Top Pipe connection with built in Construction no dissimilar and Relief Valves drip leg saves material amp time 4 metals to corrode e Less than 1 2 F degree Top Piping Connection saves loss per hour material time e Smooth coil design e Stainless Dip Tube eliminates sediment e Extruded Stainless Steel Wall collection Heat Exchanger Coil Stand Off climinates e Limited Lifetime Warranty e Patent Pending e 316L 444 stainless steel fin tube e Vertically mounted e Self cleaning e 150 psi MAWP e Designed in the U S for the U S shipping damage Electrical Wiring Polypropylene e Easy Access Protected Flue Collector Sotionalsend Terminal Strip e Corrosion resistant Advanced Controls l SETTINGS e 5 1 turn down ratio Central Heating Setpoint Standby No Demand e Easy to understand English text display re Fr e Outdoor reset maximizes fuel economy SETTINGS DHW e Priority domestic hot water meets Se ip
6. oni changing demands There are two basic settings one for Central e Connections for Primary pump Heating and one for Domestic Hot Water Both have factory pre sets for standard installation and CH pump and DHW pump require no further adjustment If desired adjusting e Automatically manages up to 16 units the settings is as easy as pushing a button When using the Outdoor Air Sensor the Central heat setpoint automatically adjusts itself in Multiple Boiler System Factory Tested 7 sz SS e Certified to ASME standards in ECR s factory Utica SSV Gas Fired Modulating Condensing Hot Water Boiler Dimensional Diagram SSV 050 1 E TOP vent Connectg Combustion Air Gas Connection f 5 alely Religi Wale Connection NPT 3 Net AHRI Ratings based on piping and pickup allowance of 1 15 Contact Technical Support before selecting boiler for installations having unusual piping and pickup requirements such as intermittent system operation extensive piping systems etc General Information See Installation Operation and Maintenance Manual for complete instructions Clearances 4 Required dis tances measured from boiler jacket BOTTOM 5 Service proper operation clearance recommendation Wire Knockouts Combustion Air amp Vent Pipe Equivalent Length Minimum Length Maximum Length Return Waber from Heating System BACK O 050 075 100 150 200 Hod Wall Hanging Brack
7. tage Intermittent Direct Spark Ignition Modulating with a 5 1 combustion turn down ratio For multiple boiler applications the control module can stage up to 16 boilers User Display interface Easy programming with text display Outdoor Temperature Sensor included Heat Exchanger High grade 316L 444 Stainless Steel Fin Coil with Flame Sight Glass Combustion Gas Valve with Premix Venturi and Blower Durable Stainless Steel Mesh Modulating Burner with 5 1 turn down ratio Direct Spark Igniter and Flame Sensor Electrical Low Voltage Terminal Strip High Voltage Junction Box and Transformer Other 30 PSI Safety Relief Valve Boiler Drain Valve and Condensate Drain with built in trap LP Converstion Kit Concentric Vent Kit 2 and 3 System Sensor For Multiple Boiler Applications Att CERTIFIED www ahridirectory org 150 psi MAWP PN 240010712 Rev 1 15 GO www uticaboilers com Contractor Assistance 800 325 5479 Tel 315 797 1310 Fax 315 797 3762

Download Pdf Manuals

image

Related Search

Related Contents

Bionaire BFH420 space heater  Philips Wall light 34212/11/86  CLEAR KB-702 User's Manual  MASTER EN SEGURIDAD Y SALUD EN EL TRABAJO  User`s Manual    User Manual - Vandenborre  

Copyright © All rights reserved.
Failed to retrieve file