Home

Utica Boilers SSC Submittal Manual

image

Contents

1. UTICA BOILERS SSC STAINLESS STEEL CONDENSING Engineer Project Name Project Location Contractor Za GR w US T APPLICATION Gas fired hot water heating boiler for indoor installations Approved for closet or alcove installations For use with natural or liquefied petroleum gases LP propane LP conversion kit provided with the boiler Wall mounted optional floor mount kit available Constructed and hydrostatically tested for maximum allowable working pressure of 150 PSIG pounds per square inch gauge in accordance with ASME boiler and pressure vessel code section IV rules for construction of heating boilers Ft CERTIFIED www ahridirectory org BOILERS INCLUDE e Wall Mount Bracket e Boiler Control Module gt Line voltage intermittent direct spark ignition Replaceable fuse extra spare fuse shipped with the control gt Controlling premix modulating gas valve and blower gt User interface with LCD screen display English text boiler status indication gt Function Programming Keys Reset Menu Enter and arrow s gt Central Heating CH and Domestic Hot Water DHW setpoints Domestic hot water priority with programmable maximum priority time gt Outdoor air sensor Programmable reset curves and warm weather shutdown or fixed water temperature operation gt Boost function temperature setting and adjustable boost time gt Integral multiple boiler control capability up to 15 b
2. Models are ENERGY STAR rated products 0 1000 Btu hr British Thermal Units Per Hour 2 Heating Capacity and AFUE Annual Fuel Utilization Efficiency are based on DOE Department of Energy test procedures 3 Net AHRI Ratings based on piping and pickup allowance of 1 15 Contact Technical Support before selecting boiler for installations having unusual piping and pickup requirements such as intermittent system operation extensive piping systems etc AN 2201 Dwyer Ave Utica NY 13501 www UticaBoilers com P N 240010478 REV B 06 2014 6ECT UTICA BOILERS Physical Data 050 075 100 20 508mm 150 200 299 23 584mm Width A 41 1041mm 16 0 406mm 40 1016mm Height B Depth C Bracket D 30 762mm 14 356mm 28 711mm 18 3 465mm Height E 31 787mm 42 1092mm Size F 1 1 4 NPT 1 1 4 NPT Water Location G 2 51mm 2 51mm Connections 5 127mm 3 76mm 3 76mm 4 114mm Location H Location I Gas Location J 4 1 2 114mm 4 1 2 114mm Connection nr PET Size K 1 2 NPT 3 4 NPT Condensate Drain Connection 3 4 NPT 3 4 NPT 111 Ib 50 kg 182 Ib 83 kg 225 Ib 102 kg 911b 41 kg 157 Ib 71kg 195 Ib 89 kg Vent Connector 2 51mm 3 76mm Vent Connector Combustion Air BL m Safety Relief Valve ss Connection 34 NPT Wall Hanging i Bracket gt A Supply Water F Gas Connection K B Ret
3. oilers Requires an optional system sensor gt Service reminder status e Boiler Combustion System gt Premix Gas valve and blower assembly with 20 100 modulating firing rate Turn down ratio 5 1 gas input gt Stainless Steel Fiber Mesh Burner gt Flame Sensor AN 2201 Dwyer Ave Utica NY 13501 www UticaBoilers com P N 240010478 REV B 06 2014 ecr UTICA BOILERS e UL listed probe type low water cutoff with status indicator lights and test feature e Heat Exchanger Assembly gt Vertically mounted single piece helical fin tube coil Manufactured out of 316L stainless steel tubing with 444 stainless steel fins welded onto the coil with a laser automated process ASME stamped with a 150 psi maximum allowable working pressure A 30psi safety relief valve is standard gt Built in Primary Secondary manifold and piping system and heat exchanger pump gt Non metallic flue gas collector with built in condensate drain trap e Electrical gt Removable low voltage terminal strip gt Line voltage junction box with DWH Pump and CH Pump connections OPTIONAL EQUIPMENT e Floor mounting stand e Multiple boiler system sensor LT CERTIFIED Models amp Capacities www ahridirectory org Net AHRI Boiler Input Rate MBH Heating ae MBH Rating Water AFUE 1 2 MBH wasscas o usso s 5 6 wesse 100 0 0 a DBS iso w 08556200 0 5 0855628 m m The UBSSC
4. urn Water F Condensate Drain Connection L a 2201 Dwyer Ave Utica NY 13501 www UticaBoilers com P N 240010478 REV B 06 2014 ECT i UTICA BOILERS CLEARANCES imine i seve O atta W Required distances measured from boiler jacket 2 Service proper operation clearance recommendation Front View Side View a 2201 Dwyer Ave Utica NY 13501 www UticaBoilers com P N 240010478 REV B 06 2014 ecr UTICA BOILERS VENTING Flue Gas Location Combustion Air Location Flue Gas Terminals e Concentric Roof Side Wall Side Wall Concentric Minimum Maximum Vent Lengths ape Pipe pipe 6 ft 6 ft 6 ft 6 ft 1 8 m 8 8 m 1 8 m 8 1 8 m 0 ft 100 ft 100 ft 100 ft 100 ft 30 5 m 15 2 m 30 5 m 30 5 m 77 m 30 5 m Equivalent Length of Venting Components eee ret mem em KORE 1 AE W RECO are DE ET KNC e WC W ECA 5 ETES es Concentric Vent Kit Polypropylene Flexible Pipe per Foot 2 5 8 Note Allowable Venting Materials Polypropylene PVC CPVC and ABS Tables shown are for vent systems utilizing PVC Refer to IOM and vent pipe manufacturers instructions for equivalent vent lengths and additional information AD 2201 Dwyer Ave Utica NY 13501 www UticaBoilers com P N 240010478 REV B 06 2014 amp ecr UTICA BOILERS a 2201 Dwyer Ave Utica NY 13501 www UticaBoilers com P N 240010478 REV B 06 2014 6ECT

Download Pdf Manuals

image

Related Search

Related Contents

Liens utiles de la Douane - Guichet Unique Export de la Guadeloupe  Meridian Audio 557 Stereo Amplifier User Manual  MULTÍMETRO DIGITAL ET-2702  Sparkle Technology FSP065-RAC  H63A - ニホンゲンマ  User guide.  StarTech.com 80x25mm Dual Ball Bearing Computer Case Fan w/ LP4 Connector  LIBRETTO INVESTARM definitivo    ISCOM4300 EOS (Ethernet over SDH) User Manual  

Copyright © All rights reserved.
Failed to retrieve file