Home
Tripp Lite SU20KRTHW User's Manual
Contents
1. Tower 2 9USTAND factors supported with optional accessories Optional mounting Qty 4 2POSTRMKITHD required Qty 2 2 9USTAND required accessory notes Primary form factor Rackmount UPS Power Module 5 14 x 17 5 x 25 82 dimensions in primary form factor height x width x depth inches UPS Power Module 13 1 x 44 5 x 65 6 dimensions in primary form factor height x width x depth cm Installed whole 32 5 system maximum rack depth inches Installed whole 82 6 system maximum rack depth cm Rack Height 12U Secondary form Tower factor UPS Power Module 44 1 weight Ibs UPS Power Module 20 weight kg UPS dimensions Includes 2 SU1000RT3UPM UPS Power modules and 2 BP240V10RT3U Battery packs Listed weights and details dimensions for UPS Power module and Included battery pack each refer to a single unit Included battery 5 25 x 17 5 x 25 pack dimensions height x width x depth inches Included battery 13 3 x 44 5 x 63 5 pack dimensions height x width x depth cm Included battery 158 7 pack weight Ibs Included battery 72 pack weight kg UPS Shipping 36 x 40 25 x 51 dimensions height x width x depth inches UPS Shipping dimensions height x width x depth cm Shipping weight Ibs Shipping weight kg Cooling method UPS housing material ENVIRONMENTAL Operating Temperature Range Storage Temperature Range Relative Humidity AC mode BTU hr ful
2. Tripp Lite 1111 West 35th Street Chicago IL 60609 USA Telephone 773 869 1234 E mail saleshelp tripplite com Model Number SU20KRTHW SmartOnline 20kVA On Line Double Conversion UPS N 1 12U Rack Tower 200 240V Hardwire output Highlights e 20kVA 20 000VA 18 000W on line double conversion UPS 0 9 power factor e 200 208 220 230 240V 50 60Hz output Economy mode option e Hot swap power and battery modules N 1 fault tolerance at loads up to 10kVA e USB RS232 amp EPO ports support for SNMP WEB and contact closure card options e Front panel LEDs with detailed LCD monitoring and control screen e Expandable runtime with optional external battery packs e Hardwire input 3 wire Hardwire output Description Tripp Lite SUZ0KRTHW 20 000VA 20kVA 18 000 watt online double conversion UPS system offers complete power protection for critical server network and telecommunications equipment in a 12U rack tower configuration This system delivers complete N 1 redundancy when used at loads up to 10kVA and non redundant operation at loads between 10 and 20kVA Fault tolerant auto bypass prevents unexpected service interruptions during UPS overload or internal fault conditions Included parallel PDU with manual bypass switching enables hot swappable replacement of all major UPS system components in both N 1 and combined operating modes Enhanced availability fault tolerance and simple hot swap replacement options make thi
3. via MODBUS protocol 1 2 9USTAND Enables Tower Placement of Rackmount UPS Systems 1 2POSTRMKITHD Enables 2 Post Rackmount Installation of 3U and Larger UPS Transformer and Battery 1 Pack Components BP240V10RT3U External Battery Pack and Cable 3U Expandable Black 3 Point Connector 1 BP240V557C 1PH BP240V787C 1PH BP240V1037C 1PH BP240V1407C 1PH SU20KXFMRT4U External battery pack for use with select Tripp Lite UPS Systems External battery pack for use with select Tripp Lite UPS Systems External battery pack for use with select Tripp Lite UPS Systems External battery pack for use with select Tripp Lite UPS Systems 18kVA 18kW Step down Isolation Transformer Converts 208 or 240V UPS utility or generator power to 120V More information including related products owner s manuals and additional technical specifications can be found online at http www tripplite com sku SU20KRTHW Copyright 2014 Tripp Lite All rights reserved All trademarks are the sole property of their respective owners Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice Photos may differ slightly from final products
4. P enabled UPS PDU and other networking devices e Optional 2POSTRMKITHD supports installation in 2 post 19 inch racks 4 required e Optional 2 9USTAND supports upright tower placement 2 required e Supports Emergency Power Off EPO via built in interface e Front panel LEDs and LCD readout with scroll controls e LED LCD display panel rotates for viewing in rackmount or tower configurations e External battery packs are field replaceable and hot swappable e Frequency conversion mode enables conversion of 60Hz to 50Hz or 50Hz to 60Hz no de rating Specifications OUTPUT Output Volt Amp 20000 Capacity VA Output kVA capacity 20 kVA Output Watt 18000 Capacity watts Output kW capacity 18 Output power factor 0 9 Output Capacity Supports up to 105 load continuously in double conversion mode 106 to 125 for 1 minute 126 to 150 for 30 Details seconds Loads over 150 trigger immediate bypass mode operation to support loads directly from mains power Double conversion mode is automatically restored as load levels are reduced to 95 or less Nominal Output 200V 208V 220V 230V 240V Voltage s Supported Nominal Voltage Voltage selection via front panel LCD interface details Frequency 50 60 Hz Supports 50 to 60 Hz and 60 to 50 Hz conversion compatibility Frequency Output frequency matches input nominal on startup Frequency conversion mode enables conversion of 60Hz to compatibility details 50Hz or 50Hz to 60Hz no de r
5. ating Output voltage 2 regulation line mode Output voltage 10 regulation Economy line mode Output voltage 2 regulation Battery mode Built in UPS output Hardwire receptacles Output AC waveform Sine wave AC mode Output AC waveform Pure Sine wave battery mode INPUT Rated input current 112 2A 200V 108A 208V 102A 220V 97 6A 230V 93 6A 240V at maximum load Nominal Input 200V AC 208V AC 220V AC 230V AC 240V AC Voltage s Supported UPS input connection type UPS input connection description Recommended Electrical Service Phase BATTERY Full load runtime minutes Half load runtime minutes Expandable battery runtime External battery pack compatibility Expandable runtime description DC system voltage VDC Battery recharge rate included batteries Battery replacement description VOLTAGE REGULATION Voltage regulation description Overvoltage correction Undervoltage correction Hardwire 3 wire single phase input L1 L2 G 120A 200V 240V L N PE or 125A 200V 208V or 240V L1 L2 G Single Phase 4 3 minutes 18 000 watts 12 5 minutes 9000 watts Runtime is expandable with external battery packs BP240V10RT3U BP240V557C 1PH BP240V787C 1PH BP240V1037C 1PH BP240V1407C 1PH For best results add external batteries in multiples of two so that both included 10kVA power modules have an equal number and ty
6. l load AC economy mode BTU hr full load AC mode efficiency rating 100 load AC economy mode efficiency rating 100 load Operating Elevation ft Audible Noise Operating Elevation m COMMUNICATIONS Communications interface Network monitoring port description PowerAlert software Communications cable 91 4 x 102 2 x 129 5 600 272 4 Fans Steel 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 0 to 95 non condensing 6830 2550 87 96 0 3000m 0 to 10 000 ft 60 dBA at front side 1 meter 0 3000 m USB HID enabled DB9 Serial EPO emergency power off Slot for SNMP Web interface Additional contact closure support with optional RELAYIOCARD and RELAYIOMINI interface cards RELAYIOMINI installation requires removal of panel containing USB ports Included USB DB9 serial and EPO cables included WatchDog Supports Watchdog application OS and hard reboot restart options for remote applications compatibility LINE BATTERY TRANSFER Transfer time Transfer time economy mode Low voltage transfer to battery power setpoint No transfer time 0 ms in online double conversion mode 8 milliseconds typical power failure response in optional economy mode 100V High voltage transfer 300V to battery power setpoint SPECIAL FEATURES Cold Start startup in battery mode during a powe
7. pe of connected battery packs 240 Less than 8 hours from 10 to 90 Hot swappable user replaceable external battery packs 2 output voltage regulation in standard online double conversion mode Corrects overvoltages up to 300V Corrects undervoltages as low as 100V LEDS ALARMS amp SWITCHES LED Indicators Front panel LCD display Alarms Alarm cancel operation Switches 6 LEDs indicate line power online mode economy bypass mode on battery charger and AC output status LCD screen offers additional information and control options Selectable LCD display with scroll and selection buttons enables UPS control and detailed monitoring options LED LCD panel rotates for viewing in rack tower formats LCD Display supports ENGLISH FRENCH GERMAN ITALIAN SPANISH and PORTUGUESE see manual Unique audible alarms for all major UPS environmental and power conditions see manual Alarm cancel switch 2 Switches control off on power status and alarm cancel self test operation 2 additional switches support set and execute scrolling LCD functions bundled PDU includes bypass switch to enable hot swap UPS power module replacement SURGE NOISE SUPPRESSION UPS AC suppression response time Instantaneous EMI RFI AC noise Yes suppression PHYSICAL Included mounting 4 sets of adjustable 4 post rack rails included one for each included 3U module accessory description Installation form 2 post rackmount 2POSTRMKITHD
8. r failure Cold start operation supported Economy mode operation Optional economy mode enables high efficiency bypass operation with a maximum output voltage variation of 10 Double conversion mode is automatically restored as mains voltage varies beyond 10 with less than 1 millisecond transfer time between modes High availability UPS features Automatic inverter bypass Manual bypass switch Detachable hot swap PDU Hot swappable UPS power module Hot swappable batteries Green amp high efficiency features High efficiency economy mode operation Support for daily startup and shutoff Schedulable daily hours of economy mode operation CERTIFICATIONS UPS Certifications Tested to UL1778 USA Tested to CSA Canada CE Meets FCC Part 15 Category A EMI ROHS Restriction of Hazardous Substances UPS Certification details WARRANTY Product Warranty Period Worldwide Related Items Optional Products IEC 61000 4 5 1995 B Surge Immunity 2 year limited warranty Related Model WEXT3 SU16 20K WEXT5 SU16 20K Description 3 Year Warranty 1 Year Extension For SU16K through SU20K Single Phase UPS Models 5 Year Warranty 3 Year Extension For SU16K through SU20K Single Phase UPS Models Qty SNMPWEBCARD For remote monitoring and control via SNMP Web or Telnet 1 RELAYIOCARD Programmable Relay I O Card 1 RELAYIOMINI 3 Relay I O Mini module 1 MODBUSCARD For remote monitoring and control
9. s UPS ideal for advanced networking applications in data centers computer rooms network closets and rugged industrial locations Package Includes e Two SU10000RT3UPM UPS power modules e Two BP240V10RT3U battery packs e SUPDMB20KHW PDU with Bypass switch e 4 post rackmount installation rails e PowerAlert software and cabling Features e Tripp Lite SU20KRTHW 20kVA 20 000VA 18 000 watt on line double conversion UPS system in 12U total rack tower configuration e Unique configuration offers 20kVA non redundant operation and automatic N 1 redundancy at load levels of 10kVA and under e Included Parallel PDU with manual bypass switch enables hot swap replacement power modules at any supported load level e Hardwire input and output connections e Maintains full time sine wave output within 2 of selectable 200 208 220 230 240V nominal e Supports 50 60Hz operation for worldwide frequency compatibility e Expandable runtime with optional external battery packs e Some external battery configurations require the use of Tripp Lite s External Battery Configuration Software see manual e Battery independent restart e Highly efficient economy mode option e Optional SNMPWEBCARD RELAYIOCARD and RELAYIOMINI interface modules available RELAYIOMINI requires removal of USB interface module e HID compliant USB interface e Includes Free PowerAlert monitoring software PowerAlert LOCAL PowerAlert NSA and PowerAlert NMS for monitoring up to 250 SNM
Download Pdf Manuals
Related Search
Related Contents
Nouveaux photocopieurs Mode d`emploi Installation & Operation Manual - Expert-CM JVC GR-DX55 Camcorder User Manual VORTEX 16 USER MANUAL SPEEDER LX-4000 - ハイスピードイメージング事業部 Lettre IIDD - mars 2013 Pentax Optio E50 Guia de instalação Start Here Copyright © All rights reserved.
Failed to retrieve file