Tripp Lite TE-700L User's Manual

image

Contents

1. Set it and leave it ON at all times All Other Countries Set to OFF when you are not using connected equipment WARNING When set to OFF UPS will not provide battery backup during a blackout or brownout Set to ON when you are using connected equipment Separate battery supported surge and surge only outlets are available only on select models identified on the back of your UPS Your UPS is designed to support only computer equipment You will overload your UPS if you connect household appliances laser printers or surge suppressors See Basic Operation section for the Switch Function UPS Conditions and Setting Advantages Optional Installation OPTION 1 select models OPTION 1 UPS Software Using Tripp Lite Cable if supplied connect the DB9 port of your UPS to the DB9 port of your computer Load software if supplied and run the installation program appropri ate for your operating system OPTION 2 Brownout Voltage Adjustment Adjust the Voltage Potentiometer UPS back panel clockwise to lower the voltage point at which the UPS switches from on line to battery output Your UPS will function properly without these connections or settings For users who experience frequent severe brownouts to avoid excessive battery drain Note Use caution when adjusting the potentiometer while the UPS is powering a voltage sensitive load Basic Operati
2. for repair warranty information The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure the equipment is not malfunctioning There are no repairs that can be made by the customer to the Fax Modem Protector This equipment may not be used on coin service provided by the telephone company Connection to party lines is subject to state tariffs Contact your state public utility commission or corporation commission for information
3. or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device e Do not connect surge suppressors to the output of your UPS This may damage your UPS and will void both the surge suppressor and UPS warranties Battery Warnings e Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside e Battery replacement must be performed by qualified service personnel Because the batteries present a risk of electrical shock and burn from high short circuit current observe proper precautions Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles and replace the existing batteries with the same number and type of new batteries Sealed Lead Acid Do not open the batteries Do not short or bridge the battery terminals with any object e The UPS batteries are recyclable Refer to local codes for disposal requirements or call 1 800 SAV LEAD 1 800 728 5323 for complete recycling information Do not dispose of the batteries in a fire e Do not attempt to add external batteries Quick Installation D Plug your UPS into an electrical outlet Plug your computer monitor and external modem into battery supported outlets Plug other equipment into surge only outlets 8 Set your UPS s OFF ON Switch USA Canada amp Western Europe
4. year warranty period enclose a copy of your sales receipt Specifications TE 300 TE 700L Output Capacity VA Watts 300 200 700 450 Battery Runtime Half Load Full Load Minutes 86 37 83 35 Battery Recharge Time 2 4 hrs 2 4 hrs Approvals UL cUL NOM UL cUL NOM Modem Fax Protection starts at 260V 1 line ALLMODELS Input Voltage Frequency 120V 60 Hz On Battery Output Voltage Range 120V 5 Output Waveform Line Mode filtered sine wave Output Waveform Battery Mode PWM sine wave AC Surge Suppression exceeds IEEE 587 Cat A amp B standards AC Noise Attenuation gt 40 dB AC Protection Modes H to N H to G N to G FCC Part 68 Notice U S only Ifyour Fax Modem Protector causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance If advance notice isn t practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC Your telephone company may make changes in its facilities equipment operations or procedures that could affect the proper operation of your equipment If it does you will be given advance notice to give you an opportunity to maintain uninterrupted service If you experience trouble with this equipment Fax Modem Protector please contact the Manager of Technical Support Tripp Lite 1111 W 35th Street Chicago Illinois 60609 Phone 773 869 1234
5. Owner s Manual TE SERIES Chicago IL 60609 USA Standby UPS Systems 120V Customer Support 773 869 1234 www tripplite com ESPANOL p 7 1 1 TRIPP LITE POWER PROTECTION 1111 W 35th Street FRANCAIS p 12 16 Safety p 2 Quick Installation p 3 Basic Operation p 4 5 Storage amp Service p 5 Specifications p 6 Copyright 1999 Tripp Lite All rights reserved Important Safety Instructions This manual contains important instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite UPS Systems SAVE THESE INSTRUCTIONS UPS Location Warnings e Install your UPS indoors away from excess moisture heat dust and direct sunlight e For best performance keep the indoor temperature between 32 F and 104 F between 0 C and 40 C e Leave adequate space around all sides of the UPS for proper ventilation UPS Connection Warnings e Connect your UPS to a three wire grounded AC power outlet Do not remove or modify the ground pin of the UPS s plug Do not use two prong adapters with the UPS s plug Do not plug your UPS into itself this will damage the UPS and void your warranty e If you are connecting your UPS to a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings e Do not use Tripp Lite UPS Systems for life support applications in which a malfunction
6. charge Leave your connected equipment ON With your UPS plugged in and turned ON move this switch to the left hold it there for 2 seconds and release it The UPS will momentarily switch to battery to test its charge If the UPS alarm sounds or the properly sized load is not supported let your UPS charge its batteries for 12 hours and repeat the test If alarm still sounds contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your network connections The UPS alarm consists of a series of short beeps followed by a brief pause The alarm is activated when the UPS switches to battery during a blackout or brownout If you experience severe brownouts that cause the UPS to fre quently switch to battery the adjustable voltage potentiometer allows you to prevent excessive battery drain by lowering the voltage point at which the UPS switches to battery Turn it clockwise to lower the voltage point as much as 18 below the nominal setting of 99 volts set fully clockwise Note Your UPS s optimal setting will depend on the voltage conditions in your area Adjust it clockwise until you reduce the frequency your UPS switches to battery Your UPS will function properly at any setting Use caution when adjusting the potentiometer while the UPS is powering voltage sensitive loads Indicator Lights All Indicator Light descriptions app
7. ly when the UPS is plugged into a wall outlet and turned ON VA This green light will turn ON whenever your UPS is plugged in and receiving normal AC line power This red light will turn ON when your UPS is providing your equipment with battery power This yellow light will turn ON after you test your UPS battery s charge with the Mute Test Switch to indicate that the UPS s battery is less than fully charged If it stays on continuously contact Tripp Lite for service The light will flash after you set the OFF ON Switch to the OFF position to indicate that the UPS will not provide battery backup during a blackout or brownout This red light will turn ON when the UPS s capacity has been exceeded while it is operating from battery power either during a self test or during a blackout Remove overload from battery supported outlets immediately m8 Gls Available on select models Other UPS Features AC Receptacles The receptacles provide your connected equipment with AC line power during normal operation They will provide battery power during blackouts and brownouts only if the OFF ON Switch is set to the ON position The receptacles also protect your equipment against damaging surges and line noise Select models however feature surge only receptacles identified on the back of your UPS that provide peripherals with surge protection without com mitting precious battery power to support
8. on Switches MUTE TEST NORM Ved Available on select models With your UPS plugged in set this switch according to the recommendations in Step 3 of the Quick Installation section ON Position Function ENABLES battery backup UPS Conditions The UPS battery is charging Power is ON at the UPS receptacles The indicator light is illuminated Setting Advantages Provides bat tery backup during blackouts or brownouts OFF Position Function DISABLES battery backup UPS Conditions The UPS battery is charging Power is ON at the UPS receptacles The v indicator light is illuminated The amp indicator light is flashing Setting Advantages continues to charge the battery when power is present while turning OFF the inverter to prevent battery backup operation when equipment is not in use Note Only UPS models equipped with a MUTE TEST switch allow you to cold start them and use them as stand alone power sources when utility power is not present To cold start your UPS first turn your UPS ON Then move the MUTE TEST switch to the left hold momentarily and release when the g indicator light begins to flash Use this momentary switch to do two things Silence the UPS alarm Move this switch to the left and release it Note When the battery is nearly depleted the alarm resumes and cannot be silenced to alert you to immediately shut down connected equipment Test your UPS s battery
9. them during blackouts DB9 Port Available on select models The DB9 port connects your UPS to any workstation or server Use with Tripp Lite software and cabling to automatically save open files and shut down equipment during a blackout This port sends contact closure signals to indicate line fail and low battery sta tus It also receives a shut down signal from the connected computer to conserve the UPS battery charge Contact Tripp Lite Customer Support for more information Battery Replacement Door Under normal conditions the original battery in your UPS willlast several years Battery replacement should be performed only by qualified service personnel Refer to Battery Warnings in the Safety section on page 2 Storage amp Service Storage First turn your UPS OFF and disconnect its power cord from the wall outlet Then disconnect all equipment to avoid battery drain If you plan on storing your UPS for an extended period of time fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 4 to 6 hours If you leave your UPS batteries discharged for an extended period of time they will suffer a permanent loss of capacity Service If returning your UPS to Tripp Lite please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the UPS is within the 2