Tripp Lite SmartOnline SU2200XLA User's Manual
Contents
1. Cooling method Battery Access ENVIRONMENTAL Relative Humidity Storage Temperature Operating Temperature Line mode BTU hr Max Battery mode BTU hr Max Audible Noise COMMUNICATIONS Network monitoring port Software and cabling included SNMP compatibility WatchDog compatibility 26 x 22 9 x 49 5 Steel Tower Built in cooling fan User replaceable hot swap battery replacement supported via battery access panel 0 to 95 non condensing 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 816 889 USB port and DB9 serial port DB9 port offers both enhanced RS 232 enabled monitoring data plus contact closure monitoring ability HID compliant USB port enables integration with built in power management and auto shutdown features of Windows and Mac OS PowerAlert Software on CD ROM and complete cabling Slot for optional SNMPWEBCARD accessory part SNMPWEBCARD Compatible with Tripp Lite s Watchdog Service Monitoring and Control Software to restore operation to locked equipment through soft reboot of application OS or hard power off on reboot of connected equipmentideal for unattended kiosk applications LINE BATTERY TRANSFER Transfer time from line power to battery mode Low voltage transfer to battery power High voltage transfer to battery power SPECIAL FEATURES EPO port Cold Start Appearance Zeroon
2. INPUT Maximum input 16A 120V 17 6 110V amps Input connection NEMA 5 20P user installable NEMA 5 15P also included type Input cord length 10ft 3m Recommended 120V 20A dedicated circuit Electrical Service BATTERY Full load runtime Half load runtime Expandable battery runtime DC system voltage Typical battery lifespan Battery recharge rate Replacement Battery Cartridge 4 5 min with internal batteries 1600W 14 min with internal batteries 800W Runtime is expandable with BP48V24 2U limit 1 or BP48V60RT3U multi pack compatible external battery packs 48VDC 3 6 years depending on usage Less than 5 hours to 90 RBC48 SUTWR VOLTAGE REGULATION Voltage regulation description Overvoltage On line double conversion power conditioning maintains output within 2 of 100 110 120 volts at all times Maintains output of selected nominal 2 during overvoltages to 138V AC correction Brownout Maintains output of selected nominal 2 during undervoltages to 65V AC at loads greater than 70 undervoltage correction correction extends to 80V LEDS ALARMS amp SWITCHES Front panel LEDs LED STATUS DISPLAY line power green online green bypass yellow on battery green overload red battery low yellow 4 LED LOAD BATTERY LEVEL DISPLAY 100 75 50 25 LED display panel easily rotates for better viewing in rackmount or tower configurations Alarms Multi function
3. web card part SNMPWEBCARD e Included PowerAlert UPS Power Management Software and cabling provides monitoring of in depth site power conditions full UPS status and fault warnings output load level and load bank power control e Compatible with Tripp Lite s WatchDog Service Monitoring and Control Software part WATCHDOGSW e Fault tolerant auto bypass maintains continuous utility output to connected equipment even in cases where the UPS is overloaded or suffers an internal failure that requires service e Diagnostic LEDs e 250 000 Ultimate Lifetime Insurance coverage for conbnected equipment USA amp Canada only e 2 year product warranty Specifications SYSTEM OVERVIEW Voltage 120V AC 110 120V compatibility Frequency 50 60 Hz compatible auto sensing compatibility OUTPUT Output VA 2200 Output watts 1600 Output nominal 120V AC 110 120V voltage Output voltage Maintains full time sine wave output within 2 of selected nominal less than 3 total harmonic distortion linear load regulation 5 total harmonic distortion computer load Less than 5 THD on line and on battery Output frequency Regulates line frequency to 50 60Hz 0 05Hz regulation Outlet quantity 6 x NEMA 5 15 20R 1 x NEMA L5 20R type Customized load 2 controllable load banks each with 3 outlets support load shedding and remote reboot on demand of locked network management devices receptacles Overload protection 30A input breaker
4. Tripp Lite 1111 West 35th Street Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 E mail saleshelp tripplite com Model SU2200XLA SmartOnline Expandable Tower UPS System On line double conversion protection for mission critical applications Highlights e 2200VA on line double conversion expandable runtime tower UPS system e Zero transfer time on line double conversion and economy mode operation supported e Simultaneous communications via HID compliant USB port serial port and SNMP web card slot e Maintains 120V 2 output during overvoltages to 138V and brownouts as low as 65V e NEMA 5 20P 120V 20A input plug 6 NEMA 5 15 20R and 1 L5 20R outlets two individually controllable three outlet load banks e Fault tolerant auto bypass e 2 year product warranty 250 000 Ultimate Lifetime Insurance USA amp Canada only Description Tripp Lite s Smart Online SU2200XLa on line double conversion UPS protects critical server networking or telecommunications equipment from blackouts brownouts voltage fluctuations and surges in an attractive all black upright tower form factor Large capacity 2200VA 1600W UPS continuously converts incoming AC to DC then back to perfect sine wave AC output at 120V AC 2 Removes harmonic distortion fast electrical impulses frequency fluctuations and other hard to solve power problems not addressed by other UPS systems True sine wave output and zero transfer
5. audible alarm with distinctive ring patterns offer notification of backup operation 2 sec on 0 5 sec off low battery warning 1 25 sec on 0 5 sec off overload sounds continuously UPS fault 4 2 sec on 1 sec off input voltage out of frequency 2 1 sec on 0 14 sec off and high input voltage 2 1 sec on 0 07 sec off Switches Includes power off on switch to enable system turn on press ON switch UPS battery test press ON switch during normal AC operation buzzer silence press ON switch during battery operation and OFF press OFF switch all switch functions require that the switch be pressed and held for longer than 2 sec but less than 4 sec SURGE NOISE SUPPRESSION AC surge 570 joules suppression AC suppression Instantaneous response time Dataline suppression EMI RFI AC noise suppression PHYSICAL Shipping weight Ibs Shipping weight kg Shipping Dimensions HWD in Shipping Dimensions HWD cm Unit weight Ibs Unit weight kg Unit Dimensions HWD in Set of 8 wire RJ style interface jacks provides surge suppression for network Ethernet or tel DSL connection Pins 1 2 3 and 6 offer Ethernet protection starting at 7 5V and the center two wires pins 4 amp 5 offer tel DSL line suppression starting at 260V Yes 59 5 27 15 25 x 13 x 24 38 7 x 33 x 61 52 7 23 9 10 25 x 9x 19 5 Unit Dimensions HWD cm Material of construction Form factors supported
6. ear warranties plus next day and on site warranty coverage available for select opportunities 3 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 2200 3000VA 5 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 2200 3000VA or less BP48V242U External Battery Pack for UPS System External Battery Pack and Cable 3U Expandable Blue 2 Point Connector Tripp Lite Power Strip Multiple outlets wherever you need them Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment Metered PDU Power Distribution Unit Safe reliable power distribution with digital current meter Switched Metered PDU with ATS Power Distribution Unit with dual input Auto Transfer Switching individual outlet control and SNMP network interface Power Management Tools UPS Communication Cable Kit for System i AS400 iSeries Servers Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU For remote monitoring and control via SNMP Web or telnet Network Surge Suppressor Essential protection for data and communication lines Network Surge Suppressor Essential protection for data and communication lines Network Surge Suppressor Essential protection for TV VCR coaxial lines More information including related products owner s manuals and additional technical specifications can be found onl
7. ine at www tripplite com en products model cfm txtModellD 3594 2009 Tripp Lite All Rights Reserved Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional
8. line UPS continuously converts incoming AC to DC then back to AC When commercial power is interrupted UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power Maintains continuous operation during undervoltages as low as 65V 80V at load levels over 70 Below this switchover point output is supported from battery derived AC power Maintains continuous operation without using battery power during overvoltages to 138V Above this point output is supported from battery derived AC power Supports Emergency Power Off via set of dedicated built in EPO jacks Inverter can be cold started to enable temporary AC output during a power failure Attractive all black color scheme BATTERY PACK ACCESSORY optional Battery Pack Accessory optional CERTIFICATIONS Certifications WARRANTY Product Warranty Period BP48V24 2U limit 1 or BP48V60RT3U multi pack compatible Tested to UL1778 USA CSA Canada NOM Mexico Class A emissions FCC Part 68 Industry Canada RoHS compliant 2 years Connected Equipment Coverage Optional Coverage Related Items Extended Warranties WEXT3 2200 3000 WEXT5 2200 3000 External Battery Packs BP48V24 2U BP48V60RT 3U Power Distribution PS7224 20T PDU1220T PDUMV20 PDUMH20ATNET Shutdown Cable Kits AS400CABLE KIT SNMP Accessories ENVIROSENSE SNMPWEBCARD Surge Protectors DTEL2 DNET1 DCATV 250 000 3 5 y
9. rgency Power Off cabling Features e True on line double conversion UPS provides a constant pure sine wave AC output e Maintains continuous operation through blackouts brownouts voltage fluctuations and surges with zero transfer time e Zero transfer time on line double conversion and economy mode operation supported e Removes harmonic distortion electrical impulses frequency variations and other hard to solve power problems e Accepts input voltages between 80V and 138V 65V to 138V at loads under 70 regulating output to 120V AC 2 e 2200VA 1600W output capacity with 7 total outlets 6 NEMA5 15 20R and 1 L5 20R e Two built in individually switchable load banks each with three outets can be controlled via software interface to selectively reboot remote equipment or automatically shed less critical loads to extend battery runtime for the most critical equipment e Standard internal battery set provides 14 min runtime at half load and 4 5 min at full load e Runtime is expandable with BP48V24 2U limit 1 or BP48V60RT3U multi pack compatible external battery packs e Attractive all black upright tower format e Simultaneous communications via HID compliant USB port serial port and SNMP web card slot e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e DB9 serial network interface supports RS 232 and contact closure messaging e Slot for optional SNMP
10. time offers guaranteed compatibility with all equipment types Includes 7 UPS supported outlets 2 three outlet load banks can be independently controlled via software interface to selectively reboot remote equipment or automatically shed less critical loads to extend battery runtime for the most critical equipment Battery support can be extended with the addition of external battery packs Includes slot for internal SNMP web card plus DB9 enhanced serial monitoring port for unattended shutdown remote control and monitoring of UPS system and power data Network management interfaces support simultaneous communications via USB port DB9 serial port and SNMPWEBCARD slot HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Includes Tripp Lite s PowerAlert UPS Power Management Software Compatible with Tripp Lite s Watchdog Service Monitoring and Control Software Applications e Ideal for protection of critical 120V equipment in server rooms internetworking closets and telecommunications systems in rackmount or tower applications Common applications include corporate or departmental servers workstations hubs routers bridges CAD CAM workstations concentrators IP telephony and traditional PBX switching systems Package Includes e SU2200XLa On line Double Conversion UPS System e PowerAlert Software and cabling e Instruction manual with warranty information e EPO Eme