Home
Tripp Lite SmartOnline SU1500RTXL2UA User's Manual
Contents
1. 600W and 5 min at full load 1200W e Optional BP48V24 2U external battery pack increases runtime limit 1 e Optional BP48V60RT3U external battery pack increases runtime multi pack compatible e Compact rackmount form factor installs using only 2 rack spaces 2U with a maximum installed depth of only 19 in e Ships with all mounting accessories for 4 post rackmount installation e Optional 2POSTRMKITWM enables 2 post rackmount or wallmount installation e Optional 2 9USTAND accessory enables small footprint upright tower placement e Fault tolerant auto bypass maintains continuous utility output to connected equipment even in cases where the UPS suffers internal failure and requires maintenance e Network interfaces support simultaneous communications via built in USB DB9 serial and SNMPWEBCARD slot e HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X e Included PowerAlert UPS monitoring software supports safe unattended shutdown monitoring and control via local connected servers plus any number of additional servers over IP e UPS interface supports on battery low battery power restored AC voltage DC voltage output current monitoring battery charge current battery capacity AC line frequency timed inverter shutoff activate self test load bank output power control and remote reboot UPS nominal voltage adjustment and UPS line to battery power voltage setpo
2. Battery Access ENVIRONMENTAL Relative Humidity Storage Temperature Operating Temperature Line mode BTU hr Max Battery mode BTU hr Max COMMUNICATIONS Network monitoring port Software and cabling included SNMP compatibility WatchDog compatibility 54 24 5 9 75 x 20 25 x 24 24 8 x 51 4 x 61 44 1 20 3 5 x 17 5 x 19 8 9 x 44 4 x 48 3 Steel Rack 2U Built in cooling fan User replaceable hot swap battery replacement supported via front access panel 0 to 95 non condensing 5 to 122 degrees Fahrenheit 15 to 50 degrees Celsius 32 to 104 degrees Fahrenheit 0 to 40 degrees Celsius 612 btu hr 87 efficiency line mode 667 btu hr 86 efficiency battery mode Includes USB and DB9 serial ports Built in DB9 port offers both enhanced RS 232 enabled monitoring data plus contact closure monitoring ability HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Yes includes PowerAlert software CD ROM and complete cabling Yes includes slot for optional SNMPWEBCARD accessory SNMPWEBCARD Yes compatible with Tripp Lite s Watchdog system service to restore operation to locked equipment through soft reboot of application OS or hard power off on reboot of connected equipmentideal for unattended kiosk applications LINE BATTERY TRANSFER Transfer time from line power to battery mode Low vo
3. Kits 2POSTRMkKITWM Shutdown Cable Kits AS400CABLE KIT SNMP Accessories ENVIROSENSE SNMPWEBCARD Surge Protectors DTEL2 DNET1 DCATV Instant Read AC Outlet Circuit Tester 3 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 1500VA or less 5 Year Extended Warranty For Smart Line Interactive and Online Tower or Rack models 1500VA or less BP48V242U External Battery Pack for UPS System External Battery Pack and Cable 3U Expandable Blue 2 Point Connector Tripp Lite Power Strip Multiple outlets wherever you need them Basic PDU Power Distribution Unit Safe reliable power distribution for critical networking equipment Universal 2 Post Rackmount Kit Supports 2U to 4U UPS systems and battery packs Power Management Tools UPS Communication Cable Kit for System i AS400 iSeries Servers Monitors temperature humidity and contact closure inputs Requires SNMPWEBCARD or switched PDU For remote monitoring and control via SNMP Web or telnet Network Surge Suppressor Essential protection for data and communication lines Network Surge Suppressor Essential protection for data and communication lines Network Surge Suppressor Essential protection for TV VCR coaxial lines Tested to UL1778 USA CSA C22 2 No 107 3 Canada NOM Mexico Class A emissions FCC Part 68 Industry 3 5 year warranties plus next day and on site warranty coverage available for sel
4. and external battery packs Attractive all black color scheme Two year warranty and 250 00 onnected equipment insurance extended warranty and service contracts available Applications e Ideal for protection of critical 120V equipment in server rooms internetworking closets and telecommunications systems in rackmount or tower applications Common applications include corporate or departmental servers workstations hubs routers bridges CAD CAM workstations concentrators IP telephony and traditional PBX switching systems Package Includes e SU1500RTXL2Ua Online Double Conversion UPS System e PowerAlert Software and cabling e Mounting hardware for 4 post rack enclosures e Instruction manual with warranty information Features e SmartOnline high performance UPS system is ideal for critical voice data medical and industrial network applications e True on line double conversion UPS provides perfectly regulated sine wave output within 2 of 100 110 120V user selectable under all usage conditions e Maintains continuous operation through blackouts voltage fluctuations and surges with zero transfer time e Removes harmonic distortion fast electrical impulses frequency variations and other hard to solve power problems not addressed by other UPS types e Corrects line voltage conditions as low as 65V and as high as 138V back to selectable 100 110 120V 2 values e Standard internal battery set offers 14 min runtime at half load
5. Recommended Electrical Service BATTERY Full load runtime Half load runtime Expandable battery runtime DC system voltage Typical battery lifespan Battery recharge rate Replacement Battery Cartridge 2 controllable load banks support load shedding and remote reboot on demand of locked network devices bankone has 2 outlets bank two has 4 outlets 20A input breaker 12A NEMA 5 15P 10 ft 3m 120V 15A 5 min with internal batteries 1200W 14 min with internal batteries 600W Supports extended runtime with optional external battery pack BP48V24 2U limit 1 and BP48V60RT 3U multi pack compatible 48VDC 3 6 years depending on usage Less than 5 hours to 90 RBC94 2U VOLTAGE REGULATION Voltage regulation description Overvoltage On line double conversion power conditioning maintains output within 2 of 100 110 120 volts at all times Maintains output of selected nominal 2 during overvoltages to 138V AC correction Brownout Maintains output of selected nominal 2 during undervoltages to 65V AC at loads greater than 70 undervoltage correction correction extends to 80V LEDS ALARMS amp SWITCHES Front panel LEDs LED STATUS DISPLAY line power green on line green bypass yellow on battery green overload red battery low yellow 4 LED LOAD BATTERY LEVEL DISPLAY 100 75 50 25 LED display panel easily rotates for better viewing in rackmount or tower configu
6. Tripp Lite 1111 West 35th Street Chicago IL 60609 USA POWER PROTECTION Telephone 773 869 1234 E mail saleshelp tripplite com Model SUISOORTXL2UA SmartOnline Expandable 2U Rack Tower UPS System On line double conversion sine wave UPS with PDU switching current monitoring and fault tolerant auto bypass Highlights e 1500VA 1 5kVA online double conversion extended run 2U rack tower UPS e Zero transfer time on line double conversion and economy mode operation supported e Maintains sine wave 100 110 or 120V 2 output during overvoltages to 138V and brownouts as low as 65V 50 60Hz auto sensing e Simultaneous communications via HID compliant USB port serial port SNMP Web card slot and EPO interface e Fault tolerant auto bypass mode current monitoring and switched PDU control via 2 switchable output load banks e Input NEMA 5 15P 120V Output 6 NEMA 5 15R 120V e 2 year product warranty 250 000 Ultimate Lifetime Insurance USA amp Canada only Description 1500VA online double conversion UPS system for critical server network and telecommunications equipment 2U rackmount form factor with an installed depth of only 19 in Expandable battery runtime with optional BP48V24 2U and BP48V60RT 3U external battery packs Full time sine wave 100 110 or 120V 2 output Uninterruptible Power Supply UPS actively converts raw incoming AC power to DC then re converts output back to completely regulated filtere
7. d AC output Operates continuously without using battery power during brownouts to 65V and overvoltages to 138V Highly efficient operation in optional economy mode setting saving BTU heat output and energy costs NEMA 5 15P input plug and NEMA 5 15R output receptacles Network grade AC surge and noise suppression Zero transfer time between AC and battery operation Network management interfaces support simultaneous communications via USB port DB9 serial port and SNMPWEBCARD slot HID compliant USB interface enables integration with built in power management and auto shutdown features of Windows and Mac OS X Supports simultaneous detailed monitoring of equipment load levels self test data and utility power conditions via all 3 network interfaces simultaneously Includes PowerAlert monitoring software and complete cabling Emergency Power Off EPO interface Integrated two bank PDU switching supports load shedding and remote reboot of connected equipment Three stage metered current monitoring and battery charge status LEDs LED display panel easily rotates for better viewing in rackmount or tower configurations Dataline surge suppression for dialup DSL or network ethernet connection Utility power and voltage regulation LEDs Audible alarm Self test Fault tolerant auto bypass mode 4 post rackmount accessories included 2 9USTAND tower kit and 2POSTRMKITWM 2 post rack amp wallmount accessories available Field replaceable hot swappable internal batteries
8. ect opportunities Contact Tripp Lite for Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Qty optional Tower Stands 2 9USTAND Tower Stand Expandable Tower Base Stand UPS Accessory Qty optional More information including related products owner s manuals and additional technical specifications can be found online at www tripplite com en products model cfm txtModellD 2949 2009 Tripp Lite All Rights Reserved
9. ints e Built in Emergency Power Off EPO interface with cable e NEMA 5 15P input plug NEMA 5 15R output receptacles e Integrated 2 bank switched PDU enables remote outlet management for load shedding or remote reboot of individual load banks bank one has 2 outlets bank two has 4 outlets e Front panel LEDs offer current monitoring and battery charge level information e UPS ships fully assembled in full compliance with DOT regulations no time consuming connection of internal batteries by user required e Supports 2 post rackmount installation with optional 2POSTRMKITWM accessory e Single line tel DSL or network Ethernet surge suppression e 2 year manufacturer s product warranty 250 000 Ultimate Lifetime Insurance Specifications SYSTEM OVERVIEW Voltage 120V AC 100 110 120V compatibility Frequency 50 60 Hz compatible auto sensing compatibility OUTPUT Output VA 1500 Output watts 1200 Output nominal 120V AC 100 110 120V voltage Output voltage Maintains full time sine wave output within 2 of selected nominal less than 3 total harmonic distortion linear load regulation 5 total harmonic distortion computer load Less than 5 THD on line and on battery Output frequency Regulates line frequency to 50 60Hz 0 05Hz regulation Outlet quantity 6 x NEMA 5 15R type Customized load management receptacles Overload protection INPUT Maximum input amps Input connection type Input cord length
10. ltage transfer to battery power High voltage transfer to battery power SPECIAL FEATURES EPO port Zero online UPS continuously converts incoming AC to DC then back to AC When commercial power is interrupted UPS maintains continuous output from battery reserves with absolutely no disruption in output AC power Maintains continuous operation during undervoltages as low as 65V 80V at load levels over 70 Below this switchover point output is supported from battery derived AC power Maintains continuous operation without using battery power during overvoltages to 138V Above this point output is supported from battery derived AC power Supports Emergency Power Off via set of dedicated built in EPO jacks Cold Start Appearance Inverter can be cold started to enable temporary AC output during a power failure Attractive all black color scheme BATTERY PACK ACCESSORY optional Battery Pack Accessory optional CERTIFICATIONS Certifications BP48V24 2U BP48V60RT3U optional Canada telecommunications WARRANTY Product Warranty Period Connected Equipment Coverage Optional Coverage 2 year product warranty 250 000 connected equipment insurance USA and Canada only additional information Related Items Audio Cables CT120 Extended Warranties WEXT3 500 1500 WEXT5 500 1500 External Battery Packs BP48V24 2U BP48V60RT 3U Power Distribution PS7224 PDU1215 Rackmount Wallmount
11. rations Alarms Multi function audible alarm with distinctive ring patterns offer notification of backup operation 2 seconds on 0 5 seconds off low battery warning 1 25 seconds on 0 5 seconds off overload sounds continuously UPS fault 4 2 seconds on 1 second off input voltage out of frequency 2 1 seconds on 0 14 seconds off and high input voltage 2 1 seconds on 0 07 seconds off Switches Includes power off on switch to enable system turn on press ON switch UPS battery test press ON switch during normal AC operation buzzer silence press ON switch during battery operation and OFF press OFF switch all switch functions require that the switch be pressed and held for longer than 2 seconds but less than 4 seconds SURGE NOISE SUPPRESSION AC surge 480 joules suppression AC suppression Instantaneous response time Dataline suppression EMI RFI AC noise suppression PHYSICAL Set of 8 wire RJ style interface jacks offer surge suppression for network ethernet or TEL DSL connection Pins 1 2 3 and 6 offer ethernet protection starting at 7 5V and the center two wires pins 4 amp 5 offer TEL DSL line suppression starting at 260V Yes Shipping weight Ibs Shipping weight kg Shipping Dimensions HWD in Shipping Dimensions HWD cm Unit weight Ibs Unit weight kg Unit Dimensions HWD in Unit Dimensions HWD cm Material of construction Form factors supported Cooling method