Home
Tripp Lite PowerVerter RV1012UL User's Manual
Contents
1. IN VICINITY OF A LEAD ACID BATTERY IS DANGEROUS BATTERIES GENERATE EXPLOSIVE GASES DURING NORMAL BATTERY OPERATION FOR THIS REASON IT IS OF UTMOST IMPORTANCE THAT EACH TIME BEFORE SERVICING EQUIPMENT IN THE VICINITY OF THE BATTERY YOU READ THIS MANUAL AND FOLLOW THE INSTRUCTIONS EXACTLY ii To reduce risk of battery explosion follow these instructions and those published by battery manufacturer and manufacturer of any equipment you intend to use in vicinity of battery Review cautionary marking on these products and on engine PERSONAL PRECAUTIONS i Someone should be within range of your voice or close enough to come to your aid when you work near a lead acid battery ii Have plenty of fresh water and soap nearby in case battery acid contacts skin clothing or eyes iii Wear complete eye protection and clothing protection Avoid touching eyes while working near battery iv If battery acid contacts skin or clothing wash immediately with soap and water If acid enters eye immediately flood eye with running cold water for at least 10 minutes and get medical attention immediately v NEVER smoke or allow a spark or flame in vicinity of battery or engine vi Be extra cautious to reduce risk of dropping a metal tool onto battery It might spark or short circuit battery or other electrical part that may cause explosion vii Remove personal metal items such as rings bracelets necklaces and watches when working with a lead acid battery A
2. lead acid battery can produce a short circuit current high enough to weld a ring or the like to metal causing a severe burn viii NEVER charge a frozen battery ix If necessary to remove battery from vessel always remove grounded terminal from battery first Make sure all accessories in the vessels are off so as not to cause an arc x Be sure area around battery is well ventilated xi Clean battery terminals Be careful to keep corrosion from coming in contact with eyes xii Study all battery manufacturer s specific precautions such as removing or not removing cell caps while charging and recommended rates of charge xiii Add distilled water in each cell until battery acid reaches level specified by battery manufacturer This helps purge excessive gas from cells Do not overfill For a battery without cell caps carefully follow manufacturer s recharging instructions MARINE CONVERTER OR INVERTER LOCATION i Locate marine converter or inverter away from battery in a separate well ventilated compartment ii Never place marine converter or inverter directly above battery gases from battery will corrode and damage marine converter iii Never allow battery acid to drip on marine converter or inverter when reading gravity or filling battery iv Do not operate marine converter or inverter in a closed in area or restrict ventilation in any way DC CONNECTION PRECAUTIONS i Connect and disconnect DC output connections only after s
3. until a properly grounded outlet can be installed by a qualified electrician DANGER Before using adapter as illustrated be certain that center screw of outlet plate is grounded The green colored rigid ear or lug extending from adapter must be connected to a properly grounded outlet make certain it is grounded If necessary replace original outlet cover plate screw with a longer screw that will secure adapter ear or lug to outlet cover plate and make ground connection to grounded outlet For all other grounded cord connected battery chargers This marine converter inverter is for use on a circuit having a nominal rating more than 120 volts or This appliance is rated more than 15 amperes and is for use on a circuit having a nominal rating of 120 volts and is factory equipped with a specific electric cord and plug to permit connection to an acceptable electric circuit Make sure that the converter or inverter is connected to an outlet having the same configuration as the plug No adapter should be used with this converter or inverter For a permanently connected marine converter or inverter GROUNDING INSTRUCTIONS This marine converter or inverter should be connected to a grounded metal permanent wiring system or an equipment grounding conductor should be run with circuit conductors and connected to equipment grounding terminal or lead on converter Connections to converter should comply with all local codes and ordinances Grou
4. Insulator Drip Shield Installation Instructions WARNING The Insulator Drip Shield is required for installation on your Tripp Lite DC to AC Inverter Charger when it is used in marine applications e g aboard watercraft Failure to install it as described below may lead to personal injury and or damage to the Inverter Charger and connected systems Installation 1 Locate and remove the four hex screws on the top panel of your Inverter Charger as shown Cae Sec f cause A Place the Insulator Drip Shield on the top panel of the Inverter Charger Line up the holes in the shield with the exposed screw holes on the top panel 3 Using the hex screws secure the Insulator Drip Shield to the top panel of the Inverter Charger S 3 I I I E 4 i pea S g 1 1 ee CE 200412030 93 2431 Owner s Manual Addendum PowerVerter RV1012UL amp RV2012UL RV amp Marine DC to AC Inverter Chargers TRIPP LITE Marine 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 UL www tripplite com Listed UL Power Inverter A US The new RV1012UL and RV2012UL are the most rugged reliable Inverter Chargers available ideal for both RV and marine applications RVs and boats often experience severe shocks while driving over potholes and rough road surfaces or while navigating in choppy seas RVs and boats also experience con
5. etting any marine converter or inverter switches to off position and removing AC cord from electric outlet or opening AC disconnect EXTERNAL CONNECTIONS TO CHARGER SHALL COMPLY WITH THE UNITED STATES COAST GUARD ELECTRICAL REGULATIONS 33CFR183 SUB PART J a b c d For all grounded cord connected marine converters or inverters GROUNDING AND AC POWER CORD CONNECTION INSTRUCTIONS Converters inverters should be grounded to reduce risk of electric shock Converter inverter is equipped with an electric cord having an equipment grounding conductor and a grounding plug The plug must be plugged into an outlet that is properly installed and grounded in accordance with all local codes and ordinances DANGER Never alter AC cord or plug provided if it will not fit outlet have proper outlet installed by a qualified electrician Improper connection can result in a risk of an electric shock For a grounded cord connected marine converter with an input rating less than 15 amperes and intended for use on a nominal 120 volt circuit This marine converter inverter is for use on a nominal 120 volt circuit and has a grounding plug that looks like the plug illustrated in sketch A in Figure 1 A temporary adapter which looks like the adapter illustrated in sketches B and C may be used to connect this plug to a two pole receptacle as shown in sketch B if a properly grounded outlet is not available The temporary adapter should be used only
6. nding method METAL SCREW COVER OF GROUNDED DUTLET BOX GROUNDING PIN CA Figure 1 ADAPTER dep
7. ses upon RV and other land based applications Please use this section in addition to page 3R of the owner s manual if you operate the RV1012UL or RV2012UL in a marine installation In marine applications a drip shield must be installed see drip shield instructions listed on the back page for installation information Important Safety Instructions ALL MARINE CONVERTERS IMPORTANT SAFETY INSTRUCTIONS A B 1 2 3 4 5 6 SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for marine converter Models RV1012UL and RV2012UL CAUTION To reduce risk of injury charge only wet cell lead acid or sealed lead acid type rechargeable batteries Other types of batteries may burst causing personal injury and damage Do not expose charger to rain or snow Use of an attachment not recommended or sold by the marine converter manufacturer may result in a risk of fire electric shock or injury to persons Do not disassemble marine converter or inverter take it to a qualified serviceman when service or repair is required Incorrect reassembly may result in a risk of electric shock or fire To reduce risk of electric shock unplug marine converter or inverter from outlet before attempting any maintenance or cleaning Turning off controls will not reduce this risk MARINE POWER CONVERTERS WITH BATTERY CHARGING FEATURE 1 2 3 4 5 WARNING RISK OF EXPLOSIVE GASES i WORKING
8. stant vibration from surface friction drive engines and on board generators The RV1012UL and RV2012UL are engineered specifically to meet the challenges of demanding RV and marine environments and are UL tested to perform reliably under the most extreme shock and vibration conditions The new RVIOI2UL and RV2012UL include all the features and functions of previous versions of the RVIOI2UL and RV2012UL listed in the enclosed owner s manual with the following exceptions Ten Point Mounting Flanges provide up to 10 connecting points for tight adhesion to the mounting surface e Splash Condensation Drip Shield Added protection for control panel against potentially disruptive moisture in marine environments required for marine applications e Battery Recharge Rate LED Meter indicates approximate recharge rate of connected RV or marine batteries e UL 458 Shock Vibration Tested performs reliably in the most demanding RV and marine environments under the most extreme shock and vibration conditions caused by potholes rough roads high seas surface friction or engine generator vibration Tested for conformity to UL458 and UL458 Marine Supplement for both RV and marine applications ATTENTION For Marine Applications See Inside For Marine Applications Only Additional Important Safety Instructions Save These Instructions VAN These safety instructions augment the instructions listed in the enclosed manual which focu
Download Pdf Manuals
Related Search
Related Contents
2008 XC Chassis Maintenance Manual Fujitsu PRIMERGY RX100 S8 iCentral Vacuum Installation Manual Samsung SV-DVD6E دليل المستخدم 4、OutlookExpress taluyers info_mai_2015-web Ewent EW-110101-100-N-P OPERATING INSTRUCTIONS FOR N450 Keel Cutter - Hy Security Management System User Manual Copyright © All rights reserved.