1. Select Models Only Using telephone cords connect your wall jack to the UPS jack marked LINE or IN and your equipment to the UPS jack marked EQUIP or OUT This will protect your equipment from surges over the phone line but you should make sure that your equipment is also protected against surges on the AC line Cac Cre SEE CLE oo oo ooo 0000 LIE IH ooo0o 2Q o 20 oo nn UPS models with Modem Fax protection can st protect two lines on one cable simultaneously If you want to protect two lines that travel through separate cables you must use Y I splitters appropriate to your application to adapt w a e e L1 COCO 00000 ada oo0000 dono them to your UPS s phone jacks O El External Batteries Select Models Only External batteries are only needed to extend runtime Adding external batteries will increase recharge time as well as runtime The illustration shows the location of your UPS s External Battery Connector where you will insert the battery pack cable Complete installation and mounting instructions for your battery pack appear in the battery pack s owner s manual Make sure that cables are fully inserted into their connectors Small sparks may result during battery connection this is normal Basic Operation Use the UPS STANDBY button to do three things O Switch you
2. Ce voyant jaune s allume si le syst me UPS alimente votre mat riel par batterie Les mod les SmartPro n ont qu une version multicolore de ce voyant pour indiquer le niveau de charge de la batterie Vert signifie que les batteries sont charg es compl tement ou presque jaune signifie qu elles sont partiellement charg es et rouge signifie que celles ci sont presque puis es VOLTAGE REGULATION r gulation de tension configurations pr d termin es seulement Ce voyant s allume quand votre syst me UPS corrige automatiquement des hausses et des baisses de tension du secteur Votre syst me UPS met galement un l ger cliquetis lorsque cette r gulation de tension automatique est activ e Ce sont des activit s normales de votre syst me UPS et aucune action n est exig e de votre part BATTERY CHARGE chargement batterie Ce voyant rouge reste allum en continu apr s l ex cution d un autotest pour indiquer que la batterie du syst me UPS est faible Si ce voyant reste toujours allum apr s les 12 heures de recharge et l ex cution d un second autotest consultez le service la client le de Tripp Lite OVERLOAD surcharge Ce voyant a diff rentes fonctions selon le mod le de votre syst me UPS Sur les mod les OmniSmart ce voyant rouge reste allum en continu lorsque le syst me UPS alimente votre quipement par batterie ou apr s l ex cution d un autotest indiquant que l onduleur est surchar
3. They will refer you to a service center Please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the UPS is within the warranty period enclose a copy of your sales receipt Specifications Tripp Lite has a policy of continuous improvement Specifications are subject to change without notice OMNISMART350HG OMNISMART450HG OMNISMART700HG Output Capacity VA Watts 330 225 450 280 700 425 Battery Runtime Half Load Full Load Minutes 46 18 38 14 22 9 Battery Recharge Time 2 4 hrs 2 4 hrs 2 4 hrs Approvals UL1778 UL2601 1 UL1778 UL1778 FCC Class B and Part 68 FCC Class B FCC Class B Modem Fax Protection 2 lines None None External Battery Type None None None SMART700HG SMART1200XLHG Output Capacity VA Watts 700 450 1000 750 Battery Runtime Half Load Full Load Minutes 42 18 28 11 Battery Recharge Time 2 4 hrs 2 4 hrs Approvals UL1778 UL2601 1 UL1778 UL2601 1 FCC Class A FCC Class A Modem Fax Protection None None External Battery Type None BP36V27 ALL MODELS Input Voltage Frequency 120V 60 Hz Output Waveform Line Mode filtered sinewave Output Waveform Battery Mode PWM sine wave AC Surge Suppression exceeds IEEE 587 Cat A amp B standards AC Noise Attenuation gt 40 dB AC Protection Modes H to N H to G N to G UL CLASSIFICATION FOR MEDICAL EQUIPMENT Class Type B Ordinary Equipment Contin
4. as Utilice herramientas con asas aisladas y reemplace las bater as con el mismo n mero y tipo de bater as nuevas selladas de plomo y cido No abra las bater as No permita que ning n objeto entre en contacto con ambos bordes o terminales de las bater as Las bater as del sistema UPS son reciclables Refi rase al reglamento local para conocer los requerimientos de desecho aplicables o en EE UU solamente llame al 1 800 SAV LEAD 1 800 728 5323 para recibir informaci n sobre el reciclaje No eche las bater as al fuego S1 su sistema UPS incluye un conector de bater as externas s lo conecte bancos de bater as externos Tripp Lite con el voltaje adecuado S1 su sistema UPS no incluye un conector de bater as externas no agregue bater as externas Instalaci n r pida il Enchufe su sistema UPS a una toma de corriente de 120 V CA 60 Hz de 3 hilos y que est conectada a tierra Este sistema UPS de grado hospitalario debe conectarse a una toma de grado hospitalario para lograr una conexi n a tierra confiable Los sistemas UPS s lo cumplen la norma UL 2601 1 para equipo m dico si se conectan a una toma de grado hospitalario Al conectarse el sistema UPS ste ejecutar una autoprueba Vea la secci n Operaci n b sica para poder entender los resultados de dicha autoprueba Fl Enchufe su equipo al sistema UPS Se sobrecargar si se le conectan aparatos con un gran consumo de energ a como dispositi
5. a self test to indicate that the UPS s battery is weakly charged If 1t remains lit after you have allowed the UPS to charge for twelve hours and have run a second self test contact Tripp Lite for service OVERLOAD This light has different functions depending on your UPS model On OmniSmart models this red light will turn ON continuously when the UPS is providing power from battery or after the UPS runs a self test to indicate that the UPS s inverter is overloaded If it lights up immediately remove some of the equipment connected to the UPS and run a self test Large overloads may cause your UPS to shut down On SmartPro models this light shows how heavy is the load on the UPS s inverter Green indicates a light load yellow indicates a medium load and red indicates a heavy load above 8596 of the UPS s output capacity If this light is flashing the UPS is overloaded and will not be able to provide power to connected equipment during a power outage Unplug equipment from the UPS until this LED stops flashing Basic Operation continued Other UPS Features Hospital Grade AC Receptacles The receptacles provide your connected equipment with AC line power during normal operation and battery power during blackouts and brownouts They also protect your equipment against damaging surges and line noise Modem Fax Protection Jacks Select Models Only These jacks protect connected equipment against surges travel
6. ciertos modelos Impide que una corriente de entrada elevada da e al sistema UPS o los aparatos conectados a l Si este fusible se dispara asegurese de que el sistema UPS est conectado a una energia nominal de 120V CA antes de restablecerlo empujando el interruptor a la posici n de restablecimiento Conexi n equipotencial s lo para ciertos modelos Se utiliza para conectar cualquier equipo que requiera de una tierra Nr para chas s Ajuste de la sensibilidad de la energ a el ctrica Ro s lo para ciertos modelos N Este indicador normalmente est ajustado totalmente en sentido contrario a las manecillas del reloj ello permite proteger al UPS de distorsiones en el modo de onda presentes en la entrada de CA Cuando se producen dichas distorsiones el sistema UPS normalmente hace un cambio para entregar una alimentaci n sinusoidal PWM mediante sus reservas de bater as durante todo el tiempo que permanezca la distorsi n En el caso de regiones en las cuales el suministro de energ a es deficiente o en aquellos casos en los que el sistema UPS se alimenta con un generador de respaldo una distorsi n cr nica en los modos de onda podr a provocar que dicho sistema cambie con demasiada frecuencia a la alimentaci n por bater as con lo cual se agotan las reservas de stas Para reducir la frecuencia con la cual el sistema UPS recurre a las bater as debido a la distorsi n de los modos onda haga pruebas con diversos valores de est
7. desactive Use el bot n MUTE TEST silenciar probar para realizar dos funciones Silenciar la alarma del UPS en bater a Oprima y mantenga oprimido este bot n para silenciar la alarma del UPS en bater a Se oir entonces una serie de sonidos cortos a los cuales les seguir una breve pausa que se activa cuando el UPS proporciona CA por medio de la bater a Nota Cuando la bater a est casi agotada la alarma indicadora de esta condici n emitir un sonido continuo que no puede silenciarse para advertirle que deben apagarse de inmediato los equipos conectados Efectuar una autoprueba El sistema UPS ejecuta una autoprueba cuando se conecta por primera vez Para que ste ejecute la autoprueba en otro momento deje activado el equipo conectado al sistema Con el UPS conectado y en el modo UPS oprima este bot n hasta que oiga un sonido aproximadamente 2 segundos luego su ltelo Resultados de una autoprueba Todas las luces LED de indicaci n estar n encendidas y el sistema UPS emitir varios sonidos cortos al cambiar moment neamente a la bater a para hacer la prueba de capacidad de carga y reserva La prueba durar un m ximo de 10 Operacion basica continuacion segundos Si el inversor est sobrecargado la luz LED x permanecer encendida y el sonido en el sistema UPS continuar despu s de la prueba si esto sucediera elimine algo de la carga y ejecute de nuevo la autoprueba Si la bater a parece esta
8. i ES votre syst me UPS gt El Batteries externes om e m configurations pr d termin es seulement Les batteries externes ne servent qu augmenter la dur e d ex cution Ajouter des batteries externes allongera le temps de recharge ainsi que la dur e d ex cution Cette illustration pr sente l emplacement du connecteur de la batterie externe de votre syst me UPS au niveau d insertion du c ble de bloc batterie Les instructions compl tes d installation et de montage de votre bloc batterie apparaissent dans le guide de l utilisateur de ce dernier Assurez vous que les c bles sont compl tement ins r s dans leurs connecteurs Il est normal que la connexion du bloc batterie produise de petites tincelles O Exploitation de base Le commutateur UPS STANDBY permet de basculer entre trois modes Changement du mode de fonctionnement du syst me UPS Le syst me UPS tant branch dans une prise c a appuyez sur le commutateur UPS STANDBY en le maintenant enfonc jusqu ce que vous entendiez un timbre pendant environ 2 secondes indiquant quil vous est possible de basculer entre les divers modes de fonctionnement Choisissez le mode de fonctionnement de votre syst me UPS en suivant les instructions s appliquant votre r gion Celles ci figurent l tape 3 de la section Installation rapide Mode UPS ACTIVE la batterie de secours Etat du syst me UPS Tant qu il
9. printers or surge suppressors to its outlets El Select UPS Operating Mode Press the UPS STANDBY button to toggle your UPS between the UPS LED lit and the STANDBY Y Y LED flashing modes Choose the operating mode based on your location USA Canada amp Western Europe Leave the UPS in the UPS mode at all times All Other Countries Put the UPS in the STANDBY mode when you are not using connected equipment WARNING When set to CHARGE ONLY the UPS will not provide battery backup during a blackout or brownout Put the UPS in the UPS mode when you are using connected equipment See Basic Operation section for a complete explanation of each mode Quick Installation optional These connections are optional Your UPS will function properly without these connections El Serial Communications Using the cable provided connect the DB9 port of your computer to the DB9 port of your UPS Download the PowerAlert UPS monitoring software program appropriate for your operating system from www tripplite com and install it on your computer aaa LE Fl USB Communications Select Models Only Using the cable provided connect the USB port of your computer to the USB port of your UPS Download the PowerAlert UPS monitoring software program appropriate for your operating system from www tripplite com and install it on your computer El Modem Fax Protection
10. re oit un courant suffisant du secteur le syst me UPS alimente ses prises c a et recharge ses batteries son voyant lumineux V reste allum Si le courant lectrique du secteur tombe en panne ou devient insuffisant le syst me UPS alimentera ses bornes en courant c a partir de ses batteries si ces derni res sont suffisamment charg es Avantages de ce mode Fournir l alimentation lectrique de la batterie lors des pannes de secteur ou des baisses de tension Mode STANDBY D SACTIVE l alimentation lectrique de la batterie Etat du syst me UPS Tant qu il re oit un courant suffisant du secteur le syst me UPS alimente ses prises c a et recharge ses batteries le voyant lumineux V clignote Avantages de ce mode Continuer charger la batterie pendant la mise sous tension tout en d sactivant l onduleur pour emp cher que la batterie ne se d charge durant les pannes de secteur lorsque l quipement n est pas utilis D marrage froid de votre syst me UPS Si vos batteries sont charg es vous pouvez d marrer votre syst me UPS froid et l utiliser en tant que source d alimentation autonome lorsque l alimentation du secteur n est pas disponible Pour effectuer un d marrage froid appuyez sur le commutateur UPS STANDBY et maintenez le enfonc jusqu ce que vous entendiez un timbre pendant environ 2 secondes puis rel chez le Le voyant lumineux s allume et les prises du s
11. syst me UPS est aliment par une g n ratrice de courant alternatif celle ci devra fournir un courant filtr et sans parasites convenant au mat riel informatique Mises en garde relatives au raccord de l quipement Ne raccordez pas les syst mes UPS Tripp Lite des appareils de maintien des fonctions vitales si leur dysfonction ou leur d faillance pourrait causer une panne ou pourrait modifier de mani re significative l ex cution de ces dispositifs Ne connectez pas de suppresseurs de surtension ou de rallonges lectriques la prise de votre syst me UPS De tels branchements peuvent endommager le syst me UPS et entra ner une annulation de sa garantie et de celle du suppresseur de surtension Importantes consignes de s curit suite VAN Mises en garde relatives la batterie Votre syst me UPS n exige pas d entretien courant Ne l ouvrez sous aucun pr texte Il n y a pas de pi ces l int rieur que l utilisateur puisse r parer par lui m me Le remplacement de la batterie doit tre confi du personnel de service qualifi Parce que les batteries posent un risque d lectrocution et de br lure caus par une intensit en court circuit lev e veuillez observer les pr cautions appropri es D branchez et mettez le syst me UPS hors circuit avant d effectuer le remplacement des batteries Remplacez les par un nombre identique de batteries du m me type batteries au plomb bac herm tique en uti
12. voltaje s lo para ciertos modelos Esta luz se encender cuando el UPS est corrigiendo autom ticamente el voltaje alto o bajo de la l nea de corriente el ctrica El UPS tambi n producir ligeros chasquidos cuando est operando la regulaci n autom tica de voltaje Ambas son funciones normales del UPS y no requieren de acci n alguna de su parte BATTERY CHARGE recarga de la bater a Esta luz roja se encender continuamente despu s de que el sistema UPS ejecute una autoprueba para indicar que la bater a est casi desgastada Si la luz permaneciera encendida despu s de haber permitido cargarse el UPS durante doce horas y ste haya ejecutado una segunda autoprueba p ngase en contacto con Tripp Lite para solicitar servicio t cnico OVERLOAD sobrecarga Esta luz cumple con diferentes funciones seg n su modelo de UPS En los modelos OmniSmart esta luz roja se encender continuamente cuando el sistema UPS est suministrando energ a el ctrica por medio de la bater a o despu s de que el UPS ha ejecutado una autoprueba para indicar que el inversor del mismo est sobrecargado Si se enciende quite inmediatamente alg n equipo conectado al UPS y ejecute una autoprueba Grandes sobrecargas pueden producir la desactivaci n del sistemaUPS En los modelos SmartPro esta luz indica la magnitud de la carga en el inversor del UPS Verde indica una carga ligera amarillo indica una carga media y rojo indica una ca
13. IQUE DES APPAREILS DE CLASSE A DU R GLEMENT DE LA FCC Note Ce mat riel a t test et s est av r tre conforme aux limites des dispositifs num riques de Classe A conform ment la Partie 15 du r glement de la FCC Ces limites sont con ues pour fournir une installation commerciale une protection raisonnable contre les brouillages nuisibles Ce mat riel produit utilise et peut mettre de l nergie de fr quence radio et s il n est pas install et utilis conform ment au guide d instructions celui ci peut causer du brouillage dans les communications radio L utilisation de ce mat riel peut causer un brouillage nuisible lequel devra tre corrig au frais de l utilisateur L utilisateur doit faire usage de c bles et de connecteurs blind s avec ce produit Tout changement ou modification apport s ce produit qui n est pas express ment accept par la partie responsable de la conformit aux normes peut annuler le droit de l utilisateur d exploiter cet quipement AVIS DE BROUILLAGE RADIO LECTRIQUE DES APPAREILS DE CLASSE B DU R GLEMENT DE LA FCC U SEULEMENT Note Ce mat riel a t test et s est av r tre conforme aux limites des dispositifs num riques de Classe B conform ment la Partie 15 du r glement de la FCC Ces limites sont con ues pour fournir une installation r sidentielle une protection raisonnable contre les brouillages nuisibles Ce mat riel produit utilise et peut mettre de l
14. Owner s Manual SmartPro amp OmniSmart Medical Grade and Hospital Grade UPS Systems 120V Input Output Line Interactive 330 1000VA Output QU QU UL1778 UL2601 1 Important Safety Instructions 2 RCE RER y ETE TN gt y Specifications Espa ol 13 Fran ais 25 C TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA Customer Support 773 869 1234 www tripplite com Copyright 2002 Tripp Lite All rights reserved SmartPro is a registered trademark of Tripp Lite OmniSmart is a trademark of Tripp Lite Important Safety Instructions SAVE THESE INSTRUCTIONS This manual contains instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite UPS Systems Failure to heed these warnings will void your warranty UPS Location Warnings Your UPS incorporates fusing only in the ungrounded phase conductor UL2601 1 certified UPS systems see Specifications must not be used in countries other than the United States and Canada and must be used only in health care facilities on grounded systems where conditions of maintenance and supervision ensure that only qualified persons will service the electrical distribution system e Install your UPS indoors away from excess moisture or heat dust or direct sunlight Your UPS is not suitable for use in the presence of a flammable anaesthetic mixtur
15. a n despu s de haberlo desenchufado hasta que el sistema UPS est desactivado Para desactivar el sistema UPS presione y mantenga presionado el bot nUPS STANDBY UPS espera Ahora ya se puede guardar el UPS Si desea almacenar este sistema UPS por un per odo prolongado recargue completamente las bater as del sistema UPS una vez cada tres meses conect ndolo a una l nea de CA que tenga corriente y permiti ndole que cargue sus bater as por un per odo de 4 a 6 horas Las bater as que permanezcan en estado de desgaste por per odos prolongados sufrir n una p rdida permanente de capacidad Servicio S1 piensa devolver este sistema UPS para efectuar reparaciones p ngase en contacto con su distribuidor o representante local de Tripp Lite De ese modo se le podr indicar el centro de servicio m s cercano Por favor empaque el sistema UPS cuidadosamente utilizando el MATERIAL ORIGINAL DE EMPAQUE incluido con la unidad Adjunte una carta describiendo los s ntomas del problema experimentado Si el sistema UPS se encuentra dentro del per odo de garant a adjunte una copia de su factura de compra Ficha t cnica La politica de Tripp Lite es de una mejora continua Estas especificaciones estan sujetas a cambios sin previo aviso OMNISMART350HG OMNISMART450HG OMNISMART700HG Capacidad de salida VA Vatios 330 225 450 280 700 425 Tiempo de operaci n de la bater a Media carga Plena carga Minutos 46 18 38 14 22 9 Tiempo de r
16. aldo El agregar bater as externas incrementar el tiempo de recarga as como el tiempo de respaldo O La ilustraci n muestra la ubicaci n del conector de bater as externas del UPS en donde usted insertar el cable del banco de bater as Siga las instrucciones para la instalaci n y el montaje del banco de bater as del manual de operaci n del mismo Aseg rese de que los cables est n perfectamente insertados dentro de sus respectivos conectores Es normal que se produzcan peque as chispas durante la conexi n de las bater as Operaci n b sica Botones Use el bot n UPS STANDBY UPS espera para realizar tres funciones O Cambiar el modo de operaci n de su sistema UPS Mientras su sistema UPS est conectado a una toma de CA accionada oprima el bot n UPS STANDBY UPS espera hasta que se oiga un sonido aproximadamente 2 segundos para alternar entre los siguientes modos de operaci n Elija el modo de operaci n del sistema UPS seg n las instrucciones regionales en el paso 3 de la secci n Instalaci n r pida e Modo del sistema UPS ACTIVA el respaldo a bater a Condiciones del sistema UPS Cuando est conectado a la l nea de servicio adecuada el sistema UPS suministra corriente a sus contactos de CA y carga sus bater as La luz indicadora V se enciende Si la energ a de la l nea de servicio falla o no es la adecuada el sistema UPS suministrar a sus contactos CA
17. alterations made by the user to this equipment or equipment malfunctions may give the telecommunications company cause to request the user to disconnect the equipment Users should ensure for their own protection that the electrical ground connections of the power utility telephone lines and internal metallic water pipe system if present are connected together This precaution may be particularly important in rural areas Caution Users should not attempt to make connections themselves but should contact the appropriate electric inspection authority or electrician as appropriate 93 2010 200201129 Manual de operaci n SmartPro y OmniSmart Sistemas UPS de grado m dico y hospitalario Entrada salida de 120V Interactivo en l nea Salida de 330 1000 VA Qu 0 UL1778 UL2601 1 Importantes instrucciones de seguridad 14 Instalaci n r pida 16 Operaci n b sica Almacenamiento y servicio IN English 1 Francais 25 cc IO es TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 EE UU Atenci n al cliente 1 773 869 1234 www tripplite com O 2002 Tripp Lite Reservados todos los derechos SmartPro es una marca registrada de Tripp Lite OmniSmart es una marca registrada de Tripp Lite Importantes instrucciones de seguridad VAN GUARDE ESTAS INSTRUCCIONES Este manual contiene advertencias e instrucciones importantes que deben seguirse durate la instalaci
18. ase contact Tripp Lite Customer Support 1111 W 35th Street Chicago Illinois 60609 Phone 773 869 1234 for repair warranty information The telephone company may ask you to disconnect this equipment from the network until the problem has been corrected or you are sure that the equipment is not malfunctioning 5 This equipment may not be used on coin service provided by the telephone company Connection to party lines is subject to state tariffs Contact your state public utility commission or corporation for information EQUIPMENT ATTACHMENT LIMITATIONS MODELS WITH THE INDUSTRY CANADA LABEL IN CANADA ONLY Notice The Industry Canada label identifies certified equipment This certification means that the equipment meets the telecommunications network protective operational and safety requirements as prescribed in the appropriate Terminal Equipment Technical Requirements Document s The Department does not guarantee the equipment will operate to the user s satisfaction Before installing this equipment users should ensure that it is permissible to be connected to the facilities of the local telecommunications company The equipment must also be installed using an acceptable method of connection The customer should be aware that the compliance with the above conditions might not prevent degradation of service in some situations Repairs to certified equipment should be coordinated by a representative designated by the supplier Any repairs or
19. ca al equipo certificado Esta certificaci n significa que el equipo cumple con los requerimientos de operaci n seguridad y protecci n de las redes de telecomunicaciones tal como se se ala en los documentos apropiados sobre los requerimientos t cnicos del equipo terminal El Departamento no garantiza que el equipo operar a entera satisfacci n del cliente Antes de instalar este equipo los usuarios se deben asegurar de est permitido conectarse a las instalaciones de la compa a local de telecomunicaciones Adem s este equipo debe instalarse utilizando un m todo de conexi n aceptable El cliente debe estar enterado de que el cumplimiento de las condiciones anteriores no podr a prevenir la degradaci n del servicio en algunas situaciones Las reparaciones del equipo certificado deben ser coordinadas por un representante designado por el proveedor Cualquier reparaci n o alteraci n realizada por el usuario a este equipo o el mal funcionamiento del mismo puede dar origen a que la compa a de telecomunicaciones solicite al usuario que desconecte el equipo Los usuarios deben asegurarse por su propia protecci n de que las conexiones el ctricas a tierra del servicio de suministro las l neas telef nicas y el sistema met lico de tuber as de agua si las hay se conecten de manera conjunta Esta precauci n es particularmente importante en las reas rurales Precauci n Los usuarios no deben tratar de efectuar las conexiones por s
20. de CA Si se utiliza otro tipo de supresor de sobretensi n que no sea Tripp Lite para conectar el UPS a la toma de corriente se anular la garant a del sistema e Si el sistema UPS recibe energ a el ctrica por medio de un generador motorizado de CA ste deber proporcionar una salida de corriente limpia y filtrada del tipo utilizado para las computadoras Advertencias sobre la conexi n del equipo No utilice los sistemas UPS de Tripp Lite en aplicaciones para el soporte de la vida humana en los cuales un fallo o mal funcionamiento de los mismos pueda causar anomal as o alterar significativamente el rendimiento del dispositivo de soporte de la vida No conecte supresores de sobretensi n o cables de extensi n a la salida del sistema UPS Esto podr a dafiarlo as como al supresor de picos e invalidar sus garant as Importantes instrucciones de seguridad continuaci n Advertencias sobre las baterias El sistema UPS no requiere mantenimiento rutinario alguno No abra el sistema UPS por ninguna raz n Esta unidad no contiene partes interiores que puedan ser reparadas por el usuario S lo personal t cnico debidamente capacitado puede realizar el cambio de las bater as Debido a que las bater as pueden provocar un choque el ctrico o quemaduras como consecuencia de una corriente elevada en corto circuito deben adoptarse las precauciones apropiadas Desconecte y apague el sistema UPS antes de reemplazar las bater
21. des effets pr judiciables INFORMATION AU CONSOMMATEUR ET EXIGENCES DE LA FCC U SEULEMENT 1 Ce mat riel est conforme la partie 68 du r glement de la FCC Une tiquette situ e sur le dessus ou le dessous de l appareil contient entre autres son num ro d enregistrement de la FCC Si on vous le demande veuillez fournir cette information votre compagnie de t l phone 2 Si votre protecteur de modem ou de t l copieur endommage le r seau t l phonique votre compagnie de t l phone peut d cider d interrompre temporairement votre service de ligne Lorsque c est possible ils vous informeront l avance Mais si un pr avis n est pas r alisable vous en serez inform dans les meilleurs d lais Vous serez avis de votre droit de d poser une plainte la FCC 3 Votre compagnie de t l phone peut effectuer des modifications ses installations son quipement ses exploitations ou ses proc dures qui peuvent affecter le fonctionnement de votre mat riel Si cette situation survient vous serez avis l avance pour vous permettre de maintenir un service ininterrompu 4 Sivotre protecteur de modem t l copieur prouve des difficult s veuillez communiquer avec le Service la client le de Tripp Lite 1111 W 35th Street Chicago Illinois 60609 composez le 1 773 869 1234 pour toute information relative aux r parations et la garantie La compagnie de t l phone peut vous demander de d connecter ce mat riel d
22. e E3 indicator light will illuminate and AC power inverted from stored battery power will be provided at the UPS receptacles Shut Down Your UPS Press and hold the UPS STANDBY button when AC line power is absent i e during a blackout or when the UPS is unplugged to deactivate your UPS Use the MUTE TEST button to do two things Silence the UPS On Battery Alarm Press and hold this button to silence the UPS On Battery alarm a series of short beeps followed by a brief pause that is activated when the UPS is providing AC power from battery Note When the battery is nearly depleted the Low Battery alarm a continuous beep that cannot be silenced will alert you to immediately shut down connected equipment Run a Self Test Your UPS performs a self test whenever it is first plugged in To have it run a self test at another time leave your connected equipment on With your UPS plugged in and in the UPS mode press and hold this button until you hear a beep about 2 seconds then release it Results of a Self Test All the LEDs will be lit and the UPS will emit several short beeps as it momentarily switches to battery to test its charge and load capacity The test will last at most 10 seconds If the Basic Operation continued inverter is overloaded the 2 LED will stay lit and the UPS will continue to beep after the test 1f this happens remove some of the load and run the self test again If the batteries seem weak th
23. e EI LED will stay lit and the UPS will continue to beep after the test 1f this happens let UPS charge its batteries for 12 hours and repeat the test If the condition persists contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove safe electrical grounding and may introduce a damaging surge into your equipment Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into an AC outlet and turned on LINE POWER This green light will turn ON whenever your UPS is receiving normal AC line power It will flash while the UPS is in CHARGE ONLY mode to indicate that the UPS will not provide battery backup during a blackout or brownout BATTERY POWER This light will turn ON when your UPS is providing your equipment with battery power SmartPro models only have a multicolored version of this LED that indicates battery charge level Green means the batteries are fully charged or nearly so yellow means the batteries are partially charged and red means the batteries are nearly depleted VOLTAGE REGULATION Select Models Only This light will turn ON when your UPS is automatically correcting high or low utility line voltage The UPS will also click gently when this automatic voltage regulation is operating These are both normal functions of your UPS and no action is required on your part BATTERY CHARGE This red light will turn ON continuously after the UPS runs
24. e indicador Al girar el indicador en sentido de las manecillas del reloj el sistema UPS es m s tolerante de las variaciones que se producen en la onda de la energ a de CA NOTA Cuando m s se recorra el indicador en sentido de las manecillas del reloj mayor ser el grado de distorsi n del modo de onda que el sistema UPS permitir que pase al equipo que tiene conectado Cuando se experimente con diferentes posiciones de este indicador opere el equipo conectado en modo de prueba protegido de manera que sea posible evaluar el efecto producido en el equipo por las distorsiones de onda de salida del sistema UPS y sin perturbar operaciones importantes NORM DELA Regulaci n autom tica de voltaje Durante las bajas de voltaje el UPS corregir autom ticamente el bajo voltaje de la l nea de CA Algunos modelos tambi n corrigen el voltaje de l nea alto durante condiciones de sobrevoltaje Cuando est funcionando la regulaci n autom tica del voltaje el UPS puede emitir un sonido de clic suave Se trata de un funcionamiento normal y autom tico del sistema UPS y no requiere de acci n alguna de su parte Almacenamiento y servicio Almacenamiento Todos los equipos conectados se deber n desactivar y a continuaci n desconectar del UPS para evitar el desgaste de la bater a Desenchufe el sistema UPS su contacto de CA PRECAUCION El sistema UPS posee una fuente de energ a interna Sus salidas pueden suministrar energ a
25. e with air oxygen or nitrous oxide e For best performance keep the indoor temperature between between 32 F and 104 F 0 C and 40 C Leave adequate space around all sides of the UPS for proper ventilation UPS Connection Warnings Connect your UPS directly to a properly grounded AC power outlet Do not plug the UPS into itself this will damage the UPS Do not modify the UPS s plug and do not use an adapter that would eliminate the UPS s ground connection Do not use extension cords to connect the UPS to an AC outlet Your warranty will be voided if anything other than Tripp Lite surge suppressors are used to connect your UPS to an outlet f the UPS receives power from a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings Do not use Tripp Lite UPS Systems for life support appliances in which a malfunction or failure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device Do not connect surge suppressors or extension cords to the output of your UPS This may damage the UPS and will void the surge suppressor and UPS warranties Important Safety Instructions continued Battery Warnings Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside Battery replacement must be performed by qualified service
26. ecarga de la bater a 2 4 hrs 2 4 hrs 2 4 hrs Certificaciones UL1778 UL2601 1 UL1778 UL1778 FCC para Clase B y Parte 68 FCC para Clase B FCC para Clase B Protecci n para fax m dem 2 l neas Ninguna Ninguna Tipo de bater a externa Ninguna Ninguna Ninguna SMART700HG SMART1200XLHG Capacidad de salida VA Vatios 700 450 1000 750 Tiempo de operaci n de la bater a Media carga Plena carga Minutos 42 18 28 11 Tiempo de recarga de la bateria 2 4 hrs 2 4 hrs Certificaciones UL1778 UL2601 1 UL1778 UL2601 1 FCC para Clase A FCC para Clase A Protecci n para fax m dem Ninguna Ninguna Tipo de bater a externa Ninguna BP36V27 TODOS LOS MODELOS Frecuencia voltaje de entrada 120 V 60 Hz modo de la forma de onda de salida de la l nea onda sinusoidal filtrada modo de la forma de onda de salida de la bater a onda sinusoidal PWM supresi n de sobrecarga de CA excede las normas IEEE Cat 587 A y B Atenuaci n de ruidos de CA gt 40 dB Modos de protecci n de CA positivo a neutro positivo a tierra y neutro a tierra CLASIFICACI N UL PARA EQUIPOS M DICOS Clase Tipo B Equipo com n Operaci n continua CERTIFICACI N UL1778 Todos los sistemas UPS descritos en este manual cumplen con la norma UL1778 Todos cumplen con requisitos estrictos para la protecci n de sistemas UPS Proporcionan respaldo de bater as durante apagones e intercambio entre el suministro de energ a y la energ a del respaldo a ba
27. g Si ce voyant s allume d connectez imm diatement une partie de l quipement du syst me UPS et ex cutez un autotest D importantes surcharges peuvent entra ner un arr t de votre syst me UPS Sur les mod les SmartPro ce voyant affiche le niveau de la charge de l onduleur du syst me UPS Le vert signifie que la charge est faible le jaune repr sente une charge moyenne et le rouge indique que cette derni re est tr s lev e plus de 85 de la capacit de puissance de sortie du syst me UPS Si ce voyant clignote le syst me UPS est surcharg et ne pourra pas fournir l alimentation lectrique au mat riel branch lors d une panne de secteur D branchez le mat riel du syst me UPS jusqu ce que le voyant ne clignote plus Exploitation de base suite Autres fonctions Bornes c a de qualit h pital Ces bornes de sortie alimentent votre mat riel en courant c a directement du secteur lors de l exploitation normale et de la batterie lors de pannes de secteur et de baisses de tension Elles prot gent galement votre mat riel contre les surtensions pr judiciables et le bruit de ligne Protection des connecteurs de modem t l copieur configurations pr d termin es seulement Ces connecteurs prot gent votre mat riel branch contre les surtensions manant d une ligne t l phonique Le branchement de mat riel ces connecteurs est facultatif Votre syst me UPS continuera fonct
28. h this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment This device complies with part 15 of the FCC rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Specifications continued FCC PART 68 CONSUMER INFORMATION AND FCC REQUIREMENTS U S A ONLY 1 This equipment complies with Part 68 of the FCC rules On the top or bottom of this equipment is a label that contains among other information the FCC registration number for this equipment If requested provide this information to your telephone company 2 f your Fax Modem Protector causes harm to the telephone network the telephone company may temporarily discontinue your service If possible they will notify you in advance But if advance notice isn t practical you will be notified as soon as possible You will be advised of your right to file a complaint with the FCC 3 Your telephone company may make changes in its facilities equipment operations or procedures that could affect the operation of your equipment If they do you will be given advance notice so as to give you an opportunity to maintain uninterrupted service 4 f you experience trouble with this Fax Modem Protector ple
29. iertos modelos Utilizando el cable incluido conecte el puerto USB de la computadora al puerto USB del UPS Descargue la versi n del programa PowerAlert de control del UPS apropiada para su sistema operativo en la direcci n de Internet www tripplite com e inst lelo en la Hin L computadora TAN KE Protecci n para m dem fax PPR Eee eee eee ee solo para ciertos modelos T Utilizando cables de tel fono conecte el enchufe de pared a la conexi n del UPS A sefialada como LINE l nea o IN l nea de entrada y su equipo con el enchufe del UPS se alado como EQUIP equipo o OUT l nea de salida Lo anterior proteger a su equipo contra sobretensiones en la l nea telef nica Sin embargo deber asegurarse de que su equipo tambi n est protegido contra sobretensiones en la l nea de CA ci Los modelos de UPS con protecci n para l m dem fax pueden proteger dos l neas en un cable simult neamente Si se desea proteger dos I lineas que viajan a trav s de cables separados fij Cac Cre SEE CLE oo oo LIE 00000 ooo0o 2Q o 20 oo nn 000 nuum L1 COCO 00000 ada oo0000 dono w D EET se debe usar los adaptadores en Y apropiados para esta instalaci n E Bater as externas s lo para algunos modelos Las bater as externas s lo son necesarias para aumentar el tiempo de resp
30. ieurs courts signaux pendant qu il passe momentan ment en mode d alimentation de secours pour v rifier la charge de la batterie Ce test ne dure pas plus de 10 secondes Si l onduleur est surcharg le voyant lumineux 2 reste allum et le syst me UPS continue mettre un timbre apr s le test Si cela se produit diminuez un peu la charge et ex cutez de nouveau l autotest Si les batteries semblent faibles le voyant lumineux I reste allum et le syst me UPS continue mettre un timbre apr s le test Si cela se produit rechargez les batteries pendant 12 heures et r p tez le test Si cela ne r sout pas le probl me communiquez avec le service la client le de Tripp Lite MISE EN GARDE Ne d branchez pas votre syst me UPS pour tester ses batteries Ceci coupe la prise de terre et peut transmettre une surtension pr judiciable votre mat riel Voyants lumineux Les descriptions des voyants lumineux ne sont applicables que si le syst me UPS est branch une prise de secteur et mis sous tension wal YN LA LINE POWER alimentation du secteur Ce voyant vert s allume tant que le syst me UPS re oit une alimentation lectrique normale du secteur Le voyant clignote si le syst me UPS est en mode CHARGE ONLY pour indiquer que ce syst me ne passera pas en mode d alimentation de secours en cas de panne de secteur ou de baisse de tension BATTERY POWER alimentation de batterie
31. ill be required to correct the interference at his own expense The user must use shielded cables and connectors with this product Any changes or modifications to this product not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC CLASS B RADIO TV INTERFERENCE NOTICE U S ONLY Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference using one or more of the following measures reorient or relocate the receiving antenna increase the separation between the equipment and the receiver connect the equipment into an outlet on a circuit different from that which the receiver is connected consult the dealer or an experienced radio television technician for help The user must use shielded cables and connectors wit
32. invertida siempre y cuando sus bater as est n lo suficientemente cargadas Ventajas de esta posici n Suministra respaldo de bater a durante apagones o bajas de voltaje e Modo STANDBY espera DESHABILITA el respaldo de bater as Condiciones del sistema UPS Cuando est conectado a la l nea de servicio el sistema UPS suministra corriente a sus contactos de CA y carga sus bater as La luz indicadora V parpadea Ventajas de esta posici n Contin a el proceso de cargar la bater a cuando hay corriente y se apaga el inversor para prevenir el agotamiento de la bater a durante los fallos del suministro el ctrico si el equipo no se encuentra en uso Arrancar en fr o el sistema UPS Se puede arrancar en fr o la unidad UPS y utilizarla como fuente aut noma de energ a cuando la energ a el ctrica no est disponible pero nicamente si se encuentra cargada la bater a del sistema UPS Para arrancar en fr o el UPS oprima el bot n UPS STANDBY UPS espera hasta que oiga un sonido aproximadamente 2 segundos cuando oiga el sonido suelte el bot n La luz indicadora E3 se iluminar y se proporcionar a sus contactos el suministro de CA invertida de la energ a almacenada en las bater as Apagar el sistema UPS Oprima el bot n UPS STANDBY UPS espera cuando no exista energ a de l nea de CA por ejemplo durante un apag n o cuando el sistema UPS est desenchufado hasta que el sistema UPS se
33. ionner correctement sans cette connexion Port s rie DB9 Le port s rie DB9 relie votre syst me UPS n importe quel poste de travail ou serveur utiliser avec le logiciel de gestion de syst me UPS PowerAlert de Tripp Lite et un c ble DB9 pour enregistrer automatiquement vos fichiers ouverts et teindre le mat riel pendant les pannes de secteur Le syst me UPS peut galement indiquer la disponibilit de l alimentation lectrique et l tat du syst me Certains mod les poss dent d autres fonctionnalit s Consultez votre manuel PowerAlert pour plus d information Port USB configurations pr d termin es seulement Le port s rie DB9 relie votre syst me UPS n importe quel poste de travail ou serveur utiliser avec le logiciel de gestion de syst me UPS PowerAlert de Tripp Lite et un c ble USB pour enregistrer automatiquement vos fichiers ouverts et teindre le mat riel pendant les pannes de secteur Le syst me UPS peut galement indiquer la disponibilit de l alimentation lectrique et l tat du syst me Certains mod les poss dent d autres fonctionnalit s Consultez votre manuel PowerAlert pour plus d information Porte de remplacement de la batterie Dans des conditions normales la batterie initiale de votre syst me UPS durera plusieurs ann es Le remplacement de la batterie ne doit tre r alis que par du personnel de service qualifi R f rez vous la rubrique Mises en garde relatives la ba
34. ling over the telephone line Connecting your equipment to these jacks is optional Your UPS will still work properly without this connection DB9 Port The DB9 port connects your UPS to any workstation or server Use with Tripp Lite s PowerAlert UPS monitoring software and a DB9 cable to enable your computer to automatically save open files and shut down equipment during a blackout The UPS can also report power availability and UPS status and select UPS models have other capabilities Consult your PowerAlert manual for more information USB Port Select Models Only The USB port connects your UPS to any workstation or server Use with Tripp Lite s PowerAlert UPS monitoring software and an USB cable to enable your computer to automatically save open files and shut down equipment during a blackout The UPS can also report power availability and UPS status and select UPS models have other capabilities Consult your PowerAlert manual for more information Battery Replacement Door Under normal conditions the original battery in your UPS will last several years Battery replacement should be performed only by qualified service persomnel Refer to Battery Warnings in the Safety section on page 2 External Battery Connector Select Models Only Use to connect one or more Tripp Lite battery packs for additional runtime Refer to Specifications and or the label next to the connector to determine the appropriate variety of battery pack
35. lisant des outils munis de poign es isolantes N ouvrez pas les batteries Veillez ce qu aucun objet ne court circuite les bornes des batteries Les batteries du systeme UPS sont recyclables Veuillez consulter les r glements de votre localit pour les conditions de recyclage ou si vous habitez les EU composez le 1 800 SAV LEAD pour obtenir plus d information Ne jetez pas les batteries au feu S1 votre syst me UPS est muni d un connecteur de batterie externe ne branchez que des bloc batteries Tripp Lite au voltage appropri Si votre syst me UPS n est pas muni d un connecteur de ce type n essayez pas d ajouter de batteries externes Installation rapide il Branchez votre syst me UPS dans une prise de secteur c a trifilaire standard de 120 Va 60 Hz avec mise a la terre Vous devez brancher un syst me UPS de qualit h pital une prise d alimentation de m me qualit pour obtenir la fiabilit de la mise a la masse Les systemes UPS homologu s UL2601 1 ne sont conformes a la norme de mat riel m dical UL 2601 1 que s ils sont reli s une prise de qualit h pital Une fois branch le syst me UPS effectue un autotest Consultez la section Exploitation de base pour comprendre les r sultats de l autotest Fl Branchez votre mat riel votre syst me UPS Vous surchargerez votre syst me UPS si vous branchez des appareils qui requi rent une alimentation lectrique haut d bit comme les grands apparei
36. ls moteur les imprimantes laser et les suppresseurs de surtension ses prises de courant El Choix du mode d exploitation du syst me UPS Appuyez sur le commutateur UPS STANDB pour faire basculer le syst me entre les modes UPS V voyant lumineux allum et STANDBY Y y voyant lumineux clignotant Choisissez le mode d exploitation du syst me en fonction de votre r gion U Canada et Europe de l Ouest e Laissez toujours le syst me UPS en mode UPS Pour tous les autres pays Laissez le syst me UPS en mode STANDBY lorsque vous n utilisez pas votre mat riel ATTENTION Lorsque positionn sur CHARGE ONLY le syst me UPS ne fournira pas d alimentation lectrique de la batterie en cas de panne de secteur ou de baisse de tension Laissez le systeme UPS en mode UPS lorsque vous utilisez votre mat riel Consultez la section Exploitation de base pour obtenir de l information d taill e sur chaque mode Installation rapide facultative Ces connexions sont facultatives Votre systeme UPS fonctionnera correctement sans ces connexions ki Communications en s rie En utilisant le cable fourmi reliez le port DB9 de votre ordinateur a celui de votre systeme UPS T l chargez le logiciel de gestion de systeme UPS PowerAlert adapt a votre syst me E d exploitation partir du site www tripplite com et installez le dans votre ordinateur E El C
37. mismos deben ponerse en contacto con la autoridad de inspecci n el ctrica correspondiente o con un electricista seg n sea m s apropiado 93 2010 200201129 Guide de l utilisateur SmartPro et OmniSmart Systemes UPS de qualit m dicale et de qualit h pital 120 volts d entr e sortie Mode interactif De 330 1000 voltamp res de sortie Qu QU UL1778 UL2601 1 Importantes consignes de s curit 26 Installation rapide 28 Exploitation de base Entreposage et entretien Ee English 1 Espa ol 13 illii a TRIPP LITE POWER PROTECTION 1111 W 35th Street Chicago IL 60609 USA Service la client le 1 773 869 1234 www tripplite com Tripp Lite 2002 Tous droits r serv s SmartPro est une marque d pos e de Tripp Lite OmniSmart est une marque de commerce de Tripp Lite Importantes consignes de s curit GARDEZ CES INSTRUCTIONS EN UN LIEU SUR Le pr sent guide contient des instructions et des mises en garde qui doivent tre suivies pendant l installation l exploitation et l entreposage de tous les syst mes UPS Tripp Lite Ne pas tenir compte de ces mises en garde annule la garantie Mises en garde relatives l emplacement du syst me UPS Votre syst me UPS n utilise des fusibles que dans le conducteur de phase non mis la masse Les syst mes UPS homologu s UL2601 1 voir sp cifications ne doivent pas tre employ s dans des pays autre
38. municaciones de radio Es probable que la operaci n de este equipo cause interferencia da ina en cuyo caso se le pedir al usuario que corrija la interferencia a su propio costo El usuario debe utilizar en este producto cables y conectores blindados Cualquier cambio o modificaci n a este producto no aprobado de manera expresa por parte del responsable del cumplimiento de las normas invalidar la autorizaci n del usuario para operar el equipo NOTIFICACI N DEL COMIT FEDERAL DE COMUNICACIONES FCC SOBRE INTERFERENCIAS DE RADIO Y TELEVISION CLASE B SOLAMENTE EN EE UU Nota Este equipo se ha probado y cumple con los l mites para dispositivos digitales de Clase B en conformidad con la Parte 15 de las reglas de la FCC Estos l mites est n dise ados para brindar protecci n razonable en contra de interferencia da ina cuando el equipo se opera en una instalaci n dom stica Este equipo genera utiliza y puede radiar energ a de radiofrecuencia y de no ser instalado y usado de acuerdo con las instrucciones suministradas en el manual de operaci n puede causar interferencias en las comunicaciones de radio No obstante no existe garant a alguna de que estas interferencias no vayan a ocurrir en una instalaci n particular Si este equipo causa interferencias da inas a la recepci n de las se ales de radio o televisi n lo cual puede determinarse encendiendo y apagando el equipo se alienta al usuario a tratar de corregir la interferencia
39. n operaci n y almacenamiento de todos los sistemas UPS de Tripp Lite De no cumplirse estas advertencias la garantia sera anulada Advertencias sobre la colocacion del UPS e Su sistema UPS contiene fusibles s lo en el conductor de fase sin conexi n a tierra Los sistemas UPS certificados por UL2601 1 v ase Especificaciones no se deben utilizar fuera de Estados Unidos y Canad y s lo se deben emplear en instalaciones de atenci n de salud en sistemas con conexi n a tierra donde las condiciones de mantenimiento y supervisi n garanticen que s lo personas calificadas reparen el sistema de distribuci n el ctrica nstale su sistema UPS bajo techo alejado de calor o humedad excesiva polvo o luz solar directa No se recomienda utilizar su sistema UPS en presencia de anest sicos inflamables mezclados con aire ox geno u xido nitroso Para lograr el mejor rendimiento mantenga la temperatura interior entre 0 C y 40 C 32 F y 104 E Mantenga suficiente espacio alrededor del sistema UPS para permitir una ventilaci n adecuada Advertencias sobre la conexi n del UPS e Conecte su sistema UPS directamente a una toma de energ a de CA con conexi n adecuada a tierra No conecte el sistema UPS a s mismo ya que esto lo da ar No modifique los conectores del UPS y no utilice un adaptador que pueda eliminar la conexi n a tierra del sistema No utilice cables de extensi n para conectar el UPS a la toma
40. nergie de fr quence radio et s il n est pas install et utilis conform ment au guide d instructions celui ci peut causer du brouillage dans les communications radio Cependant il n y a aucune garantie que du brouillage ne se produira pas dans une installation particuli re Si ce mat riel cause un brouillage nuisible la r ception radio ou t l vision ce qui peut tre d termin en mettant le dispositif hors tension et puis de nouveau en marche l utilisateur est encourag essayer de corriger le brouillage en utilisant une ou plusieurs des mesures suivantes r orientez ou d placez l antenne de r ception augmentez la distance entre le mat riel et le r cepteur branchez le mat riel dans une prise de courant sur un circuit diff rent de celui sur lequel le r cepteur est branch consultez votre concessionnaire ou un technicien exp riment en radiot l vision L utilisateur doit faire usage de c bles et de connecteurs blind s avec ce produit Tout changement ou modification apport s ce produit qui n est pas express ment accept par la partie responsable de la conformit aux normes peut annuler le droit de l utilisateur d exploiter cet quipement Ce p riph rique est conforme la Section 15 du R glement de la FCC Son utilisation est assujettie aux deux conditions suivantes 1 Ce p riph rique ne peut pas produire de brouillage nuisible et 2 il doit accepter tout brouillage recu y compris ceux qui peuvent avoir
41. nnected equipment When experimenting with different settings for this dial operate connected equipment in a safe test mode so that the effect on the equipment of any waveform distortions in the UPS s output can be evaluated without disrupting critical operations Automatic Voltage Regulation During brownouts your UPS will automatically correct low AC line voltage Select models also correct high line voltage during overvolt age conditions When automatic voltage regulation is operating your UPS may be heard to click gently This is a normal automatic opera tion of your UPS and no action is required on your part Storage amp Service Storage All connected equipment should be turned off then disconnected from the UPS to avoid battery drain Unplug your UPS from its AC receptacle CAUTION Your UPS has an internal power source Its outlets may still deliver current after it is unplugged until the UPS is deactivated To deactivate the UPS press and hold its UPS STANDBY button Your UPS is now ready for storage If you plan on storing your UPS for an extended period of time fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 4 to 6 hours If you leave your UPS batteries discharged for an extended period of time they will suffer a permanent loss of capacity Service If returning your UPS for service contact your local Tripp Lite dealer or distributor
42. ntie joignez y une copie de votre facture Specifications La politique de Tripp Lite est de poursuivre l am lioration de ses produits Les sp cifications ci jointes peuvent tre modifi es sans pr avis OMNISMART350HG OMNISMART450HG OMNISMART700HG Puissance nette VA Watts 330 225 450 280 700 425 D lai d ex cution de la batterie mi charge pleine charge en minutes 46 18 38 14 22 9 Temps de recharge de la batterie De 2 4 heures De 2 4 heures De 2 4 heures Homologations UL1778 UL2601 1 UL1778 UL1778 Classe B et Section 68 Classe B du r glement Classe B du r glement du r glement de la FCC de la FCC de la FCC Protection du modem t l copieur 2 lignes Aucune Aucune Type de batterie externe Aucune Aucune Aucune SMART700HG SMART1200XLHG Puissance nette VA Watts 700 450 1000 750 D lai d ex cution de la batterie mi charge pleine charge en minutes 42 18 28 11 Temps de recharge de la batterie Homologations De 2 4heures UL1778 UL2601 1 De 2 4heures UL1778 UL2601 1 Classe Adu r glement Classe A du r glement de la FCC de la FCC Protection du modem t l copieur Aucune Aucune Type de batterie externe Aucune BP36V27 TOUS LES MOD LES Tension et fr quence d entr e 120 volts et 60 Hz mode ligne en forme d onde de sortie onde sinuso dale filtr e mode batterie en forme d onde de sortie onde sinuso dale de modulation d impulsions en largeur suppression de
43. ommunications USB configurations as predeterminees seulement En utilisant le cable fourni reliez le port USB de votre ordinateur a celui de votre systeme UPS T l chargez le logiciel de gestion de systeme UPS PowerAlert adapt votre syst me d exploitation a partir du site www tripplite com et installez le dans votre ordinateur A El Protection du modem HI eh t l copieur configurations EHE Lb r d termin es seulement ci o A l aide de cordons t l phoniques reliez la E prise murale au connecteur marqu LINE ou IN entr e du syst me UPS et votre A quipement au connecteur UPS marqu EQUIP ou OUT sortie Votre quipement sera prot g contre la surtension manant de la ligne t l phonique mais il faudra vous assurer que votre mat riel branch est galement prot g contre la surtension sur la ligne de secteur c a Les syst mes UPS avec protection pour modem Lr t l copieur peuvent prot ger simultan ment gt deux lignes reli es un seul c ble Si vous souhaitez prot ger deux lignes t l phoniques 1 circulant sur des c bles s par s vous devez l utiliser les diviseurs Y adapt s votre ti aaa LE Cac Cre SEE CLE oo oo LIE 00000 ooo0o 2Q o 20 oo nn 000 nuum L1 COCO 00000 ada oo0000 dono CO E i application afin de les relier aux connecteurs de
44. personnel Because the batteries present a risk of electrical shock and burn from high short circuit current observe proper precautions Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles and replace the existing batteries with the same number and type of new batteries Sealed Lead Acid Do not open the batteries Do not short or bridge the battery terminals with any object The UPS batteries are recyclable Refer to local codes for disposal requirements or in the USA only call 1 800 SAV LEAD for recycling information Do not dispose of the batteries in a fire If your UPS is equipped with an external battery connector only connect Tripp Lite external battery packs of the appropriate voltage If your UPS is not equipped with an external battery connector do not attempt to add external batteries Quick Installation il Plug your UPS into a 3 wire grounded 120V AC 60 Hz utility outlet You must plug a hospital grade UPS system into a hospital grade outlet to achieve ground ing reliability UL2601 1 listed UPS systems only meet UL standard 2601 1 for medical equipment when plugged into a hospital grade outlet Your UPS will run a self test after it is plugged in See Basic Operation to understand the results of its self test A Plug your equipment into your UPS You will overload your UPS if you connect high power draw equipment such as large motor driven devices laser
45. peut demander l utilisateur de d connecter son mat riel la suite de d fauts de fonctionnement de ce dernier ou la suite de r parations ou de modifications apport es par l utilisateur Dans l int r t de leur propre s curit les utilisateurs devraient s assurer que la prise de terre du secteur des lignes t l phoniques et du r seau de canalisation d eau si pr sents sont connect s ensemble Cette pr caution peut tre particulierement importante dans les zones rurales Mise en garde Les utilisateurs ne devraient pas essayer de faire les connexions eux m mes mais devraient plut t communiquer avec un responsable de l inspection lectrique ou un lectricien comp tent 93 2010 200201129
46. r temporalmente su servicio De ser posible le notificar n por adelantado Sin embargo si no es factible la notificaci n por adelantado sta se proporcionar lo antes posible Se le informar sobre su derecho a presentar una queja ante la FCC 3 La compa a telef nica podr efectuar cambios en sus instalaciones equipo operaciones y procedimientos que afecten la operaci n del equipo Si as sucede se le notificar por adelantado de tal modo que usted tenga la oportunidad de mantener un servicio sin interrupciones 4 Si se experimentan problemas con este protector de fax m dem por favor p ngase en contacto con el departamento de atenci n a clientes de Tripp Lite 1111 W 35th Street Chicago Illinois 60609 tel fono 773 869 1234 para obtener informaci n acerca de la reparaci n o garant a La compa a de tel fonos puede solicitarle que desconecte este equipo de la red hasta que se haya corregido el problema o se asegure de que el equipo no est funcionando mal 5 Este equipo no podr utilizarse en los servicios telef nicos con monedas La conexi n a l neas telef nicas estar sujeta a las tarifas estatales correspondientes P ngase en contacto con la comisi n de servicios p blicos estatales o con la entidad proveedora para obtener m s informaci n ANEXO DE LIMITACIONES DEL EQUIPO MODELOS CON LA ETIQUETA INDUSTRIAL DE CANAD SOLAMENTE EN CANAD Notificaci n La etiqueta industrial de Canad identifi
47. r UPS s Operating Mode While your UPS is plugged into a live AC outlet press the UPS STANDBY button and hold it until you hear a beep about 2 seconds to toggle between the following operating modes Choose your UPS s operating mode based on the regional guidelines in Step 3 of the Quick Installation section e UPS Mode ENABLES battery backup UPS Conditions While receiving adequate utility line power the UPS supplies power to its AC receptacles and charges its batteries its V indicator light will be lit If the utility line power fails or becomes inadequate the UPS will supply inverted AC power to its receptacles if its batteries are sufficiently charged Setting Advantages Provides battery backup during blackouts or brownouts STANDBY Mode DISABLES battery backup UPS Conditions While receiving adequate utility line power the UPS supplies power to its AC receptacles and charges its batteries the V indicator light will be flashing Setting Advantages Continues to charge the battery when power is present while turning OFF the inverter to pre vent battery depletion during power outages when equipment is not in use Cold Start Your UPS You may cold start your UPS and use it as a stand alone power source when utility power is not present providing that the UPS battery is charged To cold start your UPS press and hold the UPS STANDBY button until you hear a beep about 2 sec onds then release it Th
48. r bastante desgastada la luz LED E permanecer encendida y el sonido en el UPS continuar despu s de la prueba si esto sucediera deje que el sistema cargue sus bater as durante 12 horas y repita la prueba Si esto continuara p ngase en contacto con Tripp Lite para solicitar servicio t cnico PRECAUCION No desenchufe el sistema UPS para probar sus bater as Esto eliminar la conexi n segura a tierra y podr a introducir una sobrecarga da ina a su equipo Luces indicadoras Todas las descripciones de luces indicadoras aplican cuando el sistema UPS est encendido y conectado a una toma de CA YN LA LINE POWER energ a de l nea Esta luz de color verde se encender cada vez que el sistema UPS est recibiendo energ a de la l nea normal de CA La luz parpadear mientras el sistema UPS est en modo CHARGE ONLY carga solamente para indicar que ste no proporcionar reserva de bater a durante un apag n o una baja de voltaje BATTERY POWER energ a de la bater a Esta luz se enciende cuando el sistema UPS est suministrando energ a de bater a a su equipo Los modelos SmartPro s lo tienen una versi n de varios colores de este LED el cual indica el nivel de carga de la bater a Verde significa que las bater as est n totalmente o casi totalmente cargadas amarillo indica que est n parcialmente cargadas y rojo significa que est n casi agotadas VOLTAGE REGULATION regulaci n de
49. ras funciones Consulte su manual de PowerAlert para obtener m s informaci n Puerto USB s lo para ciertos modelos E Puerto USB conecta el sistema UPS a cualquier estaci n de trabajo o servidor Util celo junto con el programa PowerAlert de control de sistemas UPS de Tripp Lite y un cable USB para permitir que los archivos abiertos en su computadora se guarden y el equipo se apague autom ticamente si ocurriera un apag n El UPS tambi n puede informar acerca de la disponibilidad de energ a y el estado del mismo y algunos modelos de UPS tienen otras funciones Consulte su manual de PowerAlert para obtener m s informaci n Puerta para el reemplazo de las bater as En condiciones normales las bater as originales de este sistema UPS tienen varios a os de vida til S lo deber reemplazar la bater a personal t cnico calificado V ase Advertencias sobre las bater as en la secci n Seguridad de la p gina 15 Conector de bater a externa s lo para ciertos modelos Util celo para conectar uno o m s bancos de bater as de Tripp Lite para obtener tiempo de respaldo adicional Vea las especificaciones y o la etiqueta que est junto al conector para determinar los tipos apropiados de bancos de bater as a utilizar Vea en el manual de instrucciones del banco de bater as la informaci n completa sobre la instalaci n e importantes advertencias de seguridad Operacion basica continuacion Fusible de entrada s lo para
50. rga pesada mayor del 85 de la capacidad de salida del UPS Si esta luz est parpadeando el UPS est sobrecargado y no podr proporcionar energ a al equipo conectado durante una falla en el suministro de corriente Desconecte equipos del UPS hasta que este LED deje de parpadear Operacion basica continuacion Otras caracteristicas del sistema UPS Contactos de CA de grado hospitalario Los contactos de su sistema UPS suministran energia de CA al equipo conectado durante condiciones normales de operaci n y energia de bateria durante apagones y caidas de voltaje Tambi n protegen a sus equipos contra sobretensiones da inas y ruidos en la l nea Conexiones de protecci n para m dem fax s lo para ciertos modelos Estas conexiones protegen al equipo conectado contra sobretensiones que viajan a trav s de la l nea telef nica La conexi n de los equipos a estos contactos es optativa El sistema UPS continuar funcionando apropiadamente sin esta conexi n Puerto DB9 E puerto DB9 conecta el sistema UPS a cualquier estaci n de trabajo o servidor Util celo junto con el programa PowerAlert de control de sistemas UPS de Tripp Lite y un cable DB9 para permitir que los archivos abiertos en su computadora se guarden y el equipo se apague autom ticamente si ocurriera un apag n El UPS tambi n puede informar acerca de la disponibilidad de energ a y el estado del mismo y algunos modelos de UPS tienen ot
51. s que les tats Unis et le Canada et ils ne doivent tre utilis s que dans des tablissements de soins de sant sur des syst mes mis la terre o les conditions d entretien et de surveillance garantissent que seul du personnel qualifi effectuera des r parations au syst me de distribution lectrique Installez votre syst me UPS l int rieur loin de l humidit de la chaleur excessive de la poussi re et de la lumi re directe du soleil Votre syst me UPS n est pas adapt une utilisation en pr sence d anesth sique inflammable m lang de l air de l oxyg ne ou de l oxyde nitreux Pour un meilleur fonctionnement maintenez la temp rature ambiante entre 0 C et 40 C 32 F et 104 F Laissez suffisamment d espace tout autour du syst me UPS pour maintenir une bonne ventilation Mises en garde relatives au raccord du syst me UPS Branchez directement votre syst me UPS une prise de courant alternatif munie d un contact de mise la terre Ne branchez pas votre syst me UPS sur lui m me car ceci l endommagera Ne modifiez pas la prise du syst me UPS et n utilisez pas un adaptateur qui rendrait la connexion de mise la terre du syst me inop rante N utilisez pas de rallonges lectriques lors du branchement du syst me UPS une prise c a Votre garantie sera annul e si le branchement s effectue l aide de suppresseurs de surtension autres que ceux fabriqu s par Tripp Lite e Si votre
52. surtensions c a exc de les normes de l IEEE 587 des cat gories A et B att nuation de bruit c a gt 40 dB modes de protection c a H aN H G N G CLASSIFICATION UL DU MAT RIEL M DICAL Classe type B quipement ordinaire fonctionnement en continu HOMOLOGATION UL1778 Tous les syst mes UPS d crits dans ce guide sont homologu s UL1778 Tous sont conformes des exigences tr s strictes de protection de systeme UPS Pour fournir l alimentation de secours pendant les pannes de secteur ils basculent entre l alimentation lectrique du secteur et celle de la batterie en 2 4 millisecondes Tous sont concus pour ne produire que des courants de fuite la terre extr mement faibles De plus tous sont munis de prises de courant et de bornes de qualit h pital pour r duire le risque de d connexion accidentelle du mat riel Ils sont tous adapt s une utilisation dans les h pitaux l ext rieur des zones de soins aux patients Sp cifications suite HOMOLOGATION UL2601 1 Plusieurs mod les de syst me UPS d crits dans ce guide sont homologu s UL 2601 1 voir les sp cifications Ils sont dot s d un transformateur muni d une cage de Faraday pour r duire le taux de fuite de courant cumulatif de tout mat riel branch moins de 300 microamp res Ces mod les sont adapt s une utilisation dans les h pitaux m me l int rieur de zones de soins aux patients AVIS DE BROUILLAGE RADIO LECTR
53. ter a en 2 4 milisegundos Todos est n dise ados para producir fugas hacia la conexi n a tierra extremadamente pequefias Adem s todos cuentan con conectores y contactos de grado hospitalario que reducen la posibilidad de que se produzca una desconexi n accidental del equipo Todos son aptos para uso en hospitales fuera de las reas para el cuidado de pacientes Ficha t cnica continuaci n CERTIFICACI N UL2601 1 Varios de los modelos de UPS descritos en este manual cumplen con la norma UL 2601 1 ver las especificaciones Cuentan con transformadores aislados con una jaula de Faraday que reducen a menos de 300 microamperes las corrientes de fuga acumulativas de todos los equipos con los que est n conectados Estos modelos son apropiados para uso en hospitales incluidas las reas para el cuidado de pacientes NOTIFICACI N DEL COMIT FEDERAL DE COMUNICACIONES FCC SOBRE INTERFERENCIAS DE RADIO Y TELEVISION CLASE A Nota Este equipo se ha probado y cumple con los l mites para dispositivos digitales de Clase A en conformidad con la Parte 15 de las reglas de la FCC Estos l mites est n dise ados para brindar protecci n razonable en contra de interferencia da ina cuando se opera el equipo en un ambiente comercial Este equipo genera utiliza y puede radiar energ a de radiofrecuencia y de no ser instalado y usado de acuerdo con las instrucciones suministradas en el manual de operaci n puede causar interferencias en las co
54. terie pour fournir une onde sinuso dale pure tant que la distorsion persiste Dans les r gions o l alimentation lectrique du secteur est de mauvaise qualit ou si l alimentation du syst me UPS provient d un g n rateur de secours les baisses de tension fr quentes et les distorsions chroniques de l onde peuvent faire basculer le syst me UPS vers la batterie trop souvent puisant ainsi sa charge Vous pouvez r duire la fr quence d utilisation de la batterie caus e par la distorsion de l onde en exp rimentant avec diff rents r glages de ce cadran Si vous tournez le cadran dans le sens des aiguilles d une montre le syst me UPS devient plus tol rant aux fluctuations de l onde d entr e c a NOTE Plus le cadran est r gl dans le sens des aiguilles d une montre plus le syst me UPS laissera passer de grandes fluctuations d onde au mat riel branch Quand vous exp rimentez avec les diff rents r glages du cadran n utilisez le mat riel branch qu en mode s curitaire afin d emp cher que les effets nocifs des fluctuations d onde n interrompent des activit s d importance capitale NORM DELAY R gulation de tension automatique Votre syst me UPS corrige automatiquement les baisses de tension sur le secteur Certaines configurations pr d termin es corrigent galement les hausses de tension pendant les conditions de surtension Lors de la r gulation automatique de tension votre syst me UPS peut mettre un l ger clique
55. tis Il s agit d une activit normale et automatique de votre syst me UPS qui ne n cessite aucune intervention de votre part Entreposage et entretien Entreposage Tout le mat riel branch doit tre teint puis d connect du syst me UPS pour viter d puiser la batterie D branchez votre syst me UPS de sa borne c a ATTENTION Votre syst me UPS poss de une source de courant interne Jusqu ce que le syst me UPS soit d sactiv ses prises peuvent fournir du courant m me apr s qu il est d branch Pour d sactivez le syst me UPS appuyez sur le bouton UPS STANDBY et maintenez le enfonc Votre syst me UPS est maintenant pr t tre entrepos Si vous envisagez d entreposer votre syst me UPS pour une p riode prolong e rechargez compl tement les batteries tous les trois mois en branchant le syst me une prise de secteur pendant 4 ou 6 heures Si vous laissez les batteries de votre systeme UPS d charg es pendant une p riode de temps extr mement longue elles souffriront d une perte permanente de capacit Entretien Si vous rapportez votre systeme UPS pour un entretien communiquez avec votre concessionnaire ou votre distributeur Tripp Lite local Celui ci vous r f rera a un centre de service Veuillez emballer le syst me UPS en utilisant le MATERIEL D EMBALLAGE ORIGINAL livr avec l unit Joignez y une lettre d crivant les sympt mes du probleme Si votre syst me UPS est couvert par la gara
56. to use Refer to the battery pack instruction manual for complete installation information and important safety warnings Input Breaker Select Models Only Prevents high input current from damaging the UPS or the attached load If this breaker trips make sure your UPS is connected to nominal 120V AC power before resetting the circuit breaker by pushing the breaker switch in to reset Equipotential Connection Select Models Only Use this to connect any equipment that requires a chassis ground Basic Operation continued Power Sensitivity Adjustment Select Models Only This dial is normally set fully counterclockwise which enables the UPS to protect against waveform distortions in its AC input When such distortion occurs the UPS will normally switch to providing PWM sine wave power from its battery reserves for as long as the distortion is present In areas with poor utility power or where the UPS s input power comes from a backup generator chronic waveform distortion could cause the UPS to switch to battery too frequently draining its battery reserves You may be able to reduce how often your UPS switches to battery due to waveform distortion by experimenting with different settings for this dial As the dial is turned clockwise the UPS becomes more tolerant of variations in its input power s AC waveform NOTE The further the dial is adjusted clockwise the greater the degree of waveform distortion the UPS will allow to pass to co
57. tterie la section S curit de la page 27 Connecteur de batterie externe configurations pr d termin es seulement Utilisez le pour relier des blocs batteries Tripp Lite suppl mentaires pour augmenter la dur e d ex cution R f rez vous aux sp cifications ou l tiquette proximit du connecteur pour d terminer le type de bloc batterie utiliser Consultez le guide de l utilisateur de votre batterie externe pour les instructions compl tes relatives son installation et les pr cautions prendre Exploitation de base suite Disjoncteur d entr e configurations pr d termin es seulement Il emp che le courant d entr e lev d endommager le syst me UPS ainsi que le mat riel qui y est branch Si ce disjoncteur se d clenche assurez vous que votre syst me UPS est branch une prise de secteur c a de 120 volts avant de r armer le disjoncteur en appuyant sur son commutateur Connexion quipotentielle configurations pr d termin es seulement re Utilisez cette derni re pour relier tout mat riel qui exige une prise de terre de ch ssis R glage de la sensibilit au courant configurations pr d termin es seulement Ce cadran est normalement ajust compl tement dans le sens inverse des aiguilles d une montre pour prot ger le syst me UPS contre la distorsion de l onde d entr e c a Quand une telle distorsion se produit le syst me UPS basculera normalement vers l alimentation de bat
58. u r seau t l phonique jusqu ce que le probl me soit corrig ou que vous vous soyez assur que l quipement n est pas d fectueux 5 Ce mat riel ne peut pas tre utilis avec une ligne d appareil payant fournie par la compagnie de t l phone Les connexions aux lignes partag es sont assujetties des tarifs d tat Communiquez avec votre commission d tat ou votre entreprise de services publics pour plus d information LIMITATION DU MAT RIEL POUR LES MOD LES POSS DANT LE LABEL D INDUSTRIE CANADA AU CANADA SEULEMENT Note Le label d Industrie Canada identifie le mat riel homologu Cette homologation signifie que le mat riel est conforme aux exigences de protection d utilisation et de s curit des r seaux de t l communications prescrites dans les documents d exigences techniques de mat riel terminal Le minist re ne garantit pas que le mat riel fonctionnera la satisfaction de l utilisateur Avant d installer ce mat riel les utilisateurs devraient s assurer qu il est permis de le brancher au r seau de la compagnie de t l communications locale Le mat riel doit galement tre install selon une m thode de connexion acceptable Le consommateur est averti que la conformit aux conditions ci dessus n emp chera pas la d gradation du service dans certains cas La r paration du mat riel homologu doit tre coordonn e par un repr sentant d sign par le fournisseur La compagnie de t l communications
59. uous Operation UL1778 APPROVAL All the UPS systems described in this manual are UL1778 listed All meet strict requirements for UPS protection They provide battery backup during blackouts switching between utility power and battery backup power in 2 4 milliseconds All are designed to produce extremely low leakage to ground In addition all have hospital grade plugs and receptacles that reduce the possibility of accidental equipment disconnection All are suitable for use in hospitals outside patient care areas UL2601 1 APPROVAL Several of the UPS models described in this manual are UL 2601 1 listed see specifications They incorporate Faraday shielded isola tion transformers that reduce the cumulative leakage current of all connected equipment to below 300 microamps These models are suitable for use in hospitals including inside patient care areas FCC CLASS A RADIO TV INTERFERENCE NOTICE Note This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when operated in a com mercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause interference to radio communications Operation of this equipment is likely to cause harmful interference in which case the user w
60. utilizando una o m s de las siguientes medidas reorientar o colocar en otra posici n la antena receptora aumentar la separaci n entre el equipo y el receptor conectar el equipo en un contacto de un circuito diferente al que est conectado el receptor consultar a un distribuidor o t cnico con experiencia en radio y televisi n para recibir asistencia El usuario debe utilizar en este producto cables y conectores blindados Cualquier cambio o modificaci n a este producto no aprobado de manera expresa por parte del responsable del cumplimiento de las normas invalidar la autorizaci n del usuario para operar el equipo Este dispositivo cumple con las reglas de la Parte 15 de la FCC La operaci n adecuada est sujeta a las siguientes dos condiciones 1 Este dispositivo no debe causar interferencias da inas y 2 Este dispositivo debe aceptar cualquier interferencia recibida incluyendo la interferencia que podr a causar una operaci n no intencional INFORMACI N AL CONSUMIDOR Y REQUISITOS DE LA PARTE 68 DE LA AGENCIA FCC SOLAMENTE EN EE UU 1 Este equipo cumple con las reglas de la Parte 68 de la FCC En la parte superior o en el fondo de este equipo se encuentra una etiqueta que contiene entre otros el n mero de registro FCC para este equipo Si se le solicita proporcione esta informaci n a la compa a telef nica 2 Si el protector del fax m dem provoca da os a la red telef nica la compa a de tel fonos podr a descontinua
61. vos de gran dimensi n impulsados por motor impresoras l ser o supresores de sobretensiones Kl Selecci n del modo de operaci n del UPS Oprima el bot n UPS STANDBY para alternar el sistema entre los modos UPS LED encendido y STANDBY espera LED Y parpadeando Elija el modo de operaci n seg n su ubicaci n EE UU Canad y Europa Occidental Deje el sistema siempre en el modo UPS El resto de los pa ses Ponga el sistema en el modo STANDBY espera cuando no est utilizando los equipos conectados al mismo ADVERTENCIA Cuando el interruptor est en la posici n CHARGE ONLY carga de bater a solamente el sistema UPS no suministrar energ a de bater a durante un apag n o baja de voltaje Ponga el sistema en el modo UPS cuando est utilizando los equipos conectados al mismo V ase la secci n Operaci n b sica para obtener una explicaci n m s completa de cada modo Instalaci n r pida optativa Estas conexiones son optativas Este sistema UPS funcionar correctamente sin estas conexiones il Comunicaciones en serie Utilizando el cable incluido conecte el puerto DB9 de la computadora al puerto DB9 del UPS Descargue la versi n del programa PowerAlert de control del UPS apropiada para su sistema operativo en la direcci n de Internet www tripplite com e inst lelo en la a computadora 11 Fl Comunicaciones USB x Aza s lo para c
62. yst me UPS seront aliment es en tension c a par l nergie emmagasin e dans la batterie de secours Arr t de votre systeme UPS Pour d sactiver le syst me appuyez et maintenez enfonc le commutateur UPS STANDBY quand aucune alimentation du secteur ne passe par exemple durant une panne de secteur ou lorsque le syst me UPS est d branch Le bouton MUTE TEST sourdine test a deux usages Arr t de l alarme de la batterie du syst me UPS Appuyez sur le commutateur et maintenez le enfonc pour mettre l alarme de la batterie du syst me UPS en sourdine celle ci met une s rie de courts signaux suivis d une br ve pause lorsque l alimentation lectrique c a est fournie par la batterie Note Lorsque la batterie est presque puis e l alarme de batterie faible met un son continu ne pouvant tre mis en sourdine pour vous avertir de d brancher imm diatement tout votre mat riel informatique Ex cution d un autotest de syst me UPS Votre syst me UPS effectue un autotest lors de son branchement initial Pour qu un nouvel autotest soit ex cut un autre moment laissez le mat riel sous tension Le syst me tant branch et en mode UPS appuyez sur ce commutateur et maintenez le enfonc jusqu ce que vous entendiez un timbre pendant environ 2 secondes puis rel chez le Exploitation de base suite R sultats d un autotest Tous les voyants s allument et le syst me UPS met plus