1. Owner s Manual OMNIPRO 500 TRIPP LITE POWER PROTECTION 1111 W 35th Street H i aedo IL aan Line Interactive UPS System 120V Customer Support 773 869 1234 ES PAN ro ie p 7 www tripplite com oe REV M Safety p 2 Quick Installation p 3 Basic Operation p 4 5 Storage amp Service p 6 Specifications p 7 Copyright 2000 Tripp Lite All rights reserved OmniPro is a trademark of Tripp Lite A This manual contains important instructions and warnings that should be followed during the installation operation and storage of all Tripp Lite UPS Systems UPS Location Warnings e Install your UPS indoors away from excess moisture or heat dust or direct sunlight e For best performance keep the indoor temperature between 32 F and 104 F between O C and 40 C e Leave adequate space around all sides of the UPS for proper ventila tion UPS Connection Warnings e Connect your UPS to a three wire grounded AC power outlet Do not remove or modify the ground pin of the UPS s plug Do not use two prong adapters with the UPS s plug Do not plug your UPS into itself this will damage the UPS and void your warranty e If you are connecting your UPS to a motor powered AC generator the generator must provide clean filtered computer grade output Equipment Connection Warnings e Do not use Tripp Lite UPS Systems for life support applications in which a malfunction or fai
2. usando los equipos conectados ADVERTENCIA Cuando este interruptor est en la posici n de apagado OFF el No break o Sistema UPS no proporcionar energ a de respaldo durante una ca da de voltaje o apag n Vea la secci n Operaci n B sica para obtener informaci n sobre las Funciones del Interruptor Condiciones del No break o Sistema UPS y Ventajas de las Diferentes Posiciones Operacion Basica Interruptores Con el no break sistema UPS conectado a una toma el ctrica OFF ON coloque este interruptor en la posici n deseada de acuerdo con las recomendaciones especificadas en el Paso 3 de la secci n Instalaci n R pida Posici n ON encendido Funci n ACTIVA el respaldo a bater a Condiciones del No break Sistema UPS Las bater as del no break sistema UPS son recargadas La energ a est disponible en los recept culos del no break sistema UPS La luz indicadora v est encendida Ventajas de esta Posici n El no break sistema UPS suministra energ a de bater a durante caidas de voltaje o interrupciones en el suministro de la energ a el ctrica Posici n OFF apagado Funci n DESACTIVA el respaldo a bater a Condiciones del No break Sistema UPS Las bater as del no break sistema UPS son recargadas La energ a est disponible en los recept culos del no break sistema UPS La luz indicadora vn est encendida La luz indicadora j4 parpadea Venta
3. UPS provides AC power from battery during power failures OFF Position Function DISABLES battery backup UPS Conditions The UPS battery is charging Power is ON at the UPS receptacles The v indicator light is illuminated The amp indicator light is flashing Setting Advantages UPS does not provide AC power from battery during power outages conserving battery power when equipment is not in use Use this momentary switch to do three things Silence the UPS On Battery alarm Move this switch to the left and release it to silence the UPS On Battery alarm a series of short beeps followed by a brief pause that is activated when the UPS is providing AC power from battery Note When the battery is nearly depleted the Low Battery alarm a continuous beep that cannot be silenced will alert you to immediately shut down connected equipment Test your UPS s battery charge Leave your connected equipment ON With your UPS connected to AC power and turned ON move this switch to the left hold it there for 2 seconds and release it The UPS will emit several short beeps as it momentarily switches to battery to test its charge If the UPS Low Battery alarm sounds a long continuous beep or the properly sized load is not supported let your UPS charge its batteries for 12 hours and repeat the test If alarm still sounds contact Tripp Lite for service CAUTION Do not unplug your UPS to test its batteries This will remove safe electric
4. culos solamente con supresi n de sobretensiones transitorias identificados en la parte posterior del No break o Sistema UPS que proporcionan protecci n contra sobretensiones transitorias para sus equipos perif ricos sin comprometer la valiosa energia de la bateria para respaldarlos durante apagones 11 Contactos Telefonicos Tipo RJ11 Estos contactos protegen sus equipos contra picos en las lineas KUN y it telefonicas La conexion de sus equipos a estos contactos es opcional El sistema UPS funcionar adecuadamente a n sin esta conexi n Puerta para el Reemplazo de la Bater a Bajo condiciones normales la bater a original incluida con el sistema UPS durar varios a os El reemplazo de la bater a debe ser realizado solamente por personal t cnico capacitado Refi rase a la secci n Advertencias Sobre la Bateria en la p gina 8 Almacenamiento y Servicio Almacenamiento Primero apague el sistema UPS y desconecte su cable de la linea de CA Despu s desconecte todos sus equipos para evitar el desgaste de la bater a Si usted necesita almacenar su sistema UPS por un periodo extendido de tiempo recargue totalmente las bater as una vez cada tres meses encendiendo y conectando el sistema UPS a una linea activa de CA y permitiendo que el sistema UPS cargue sus bater as por 4 6 horas Si usted mantiene las bater as descargadas por un periodo extendido de tiempo stas sufrir n la p rdida permane
5. al grounding and may introduce a damaging surge into your network connections Cold Start your UPS If your UPS is equipped with a MUTE TEST switch you may cold start it and use it as a stand alone power source when utility power is not present providing that the UPS s battery is charged To cold start your UPS first turn the OFF ON switch ON Then move the MUTE TEST switch to the left hold momentarily and release when the H indicator light begins to flash Indicator Lights All Indicator Light descriptions apply when the UPS is plugged into a wall outlet and turned on This green light will turn ON whenever your UPS is plugged in and receiving normal AC line power This red light will turn ON when your UPS is providing your E equipment with battery power This yellow light will turn ON continuously when the UPS switches to battery to indicate that the UPS s battery is less than fully charged If it stays on after twelve hours of charging contact Tripp Lite for service This light will flash after you set the OFF ON Switch to the OFF position to indicate that the UPS will not provide battery backup during a blackout or brownout Whenever your UPS is correcting high or low AC line voltage this green light will turn ON with a gentle click This is a normal automatic operation of your UPS and no action is required on your part Other UPS Features The receptacles provide your connected equipmen
6. eriodo de 12 horas y repita esta prueba Si la alarma sonara nuevamente comuniquese con Tripp Lite para obtener informaci n sobre el servicio de reparaciones Precau tion No desenchufe el no break sistema UPS para probar sus bater as Esto eliminar la conexi n a tierra y podr a introducir peligrosas sobretensiones transitorias a sus conexiones de red 10 Arrancar en frio el no break sistema UPS Usted puede arrancar en frio su unidad y utilizarla como fuente autonoma de energia cuando la energia el ctrica no est disponible pero unicamente si las baterias del no break sistema UPS contienen suficiente carga Para arrancar en frio su no break sistema UPS primero coloque el interruptor OFF ON encendido apagado en la posici n ON encendido Despu s mueva el interruptor MUTE TEST silenciar probar hacia la izquierda sost ngalo moment neamente y su ltelo cuando la luz indicadora 3 comience a parpadear Luces Indicadoras Todas las descripciones de la Luces Indicadoras son efectivas mientras el Sistema UPS est conectado a una l nea viva de CA y haya sido encendido ON Esta luz verde se iluminar mientras el sistema UPS est conectado y recibiendo energia normal de CA Esta luz roja se iluminar mientras el sistema UPS est suministrando energ a de bater a a sus equipos Esta luz amarilla se iluminar continuamente despu s de realizada la prueba de carga de
7. jas de esta Posici n El no break sistema UPS contin a cargando sus bater as cuando la energ a el ctrica est disponible mientras que el inversor de energ a se apaga para prevenir el desgaste innecesario de las bater as cuando los equipos conectados no est n en uso Utilice este interruptor moment neo para realizar tres funciones MUTE TEsST Silenciar de la alarma de apagones MT Mueva este interruptor hacia la izquierda y su ltelo la alarma del no break sistema UPS consiste de una serie de sonidos cortos seguidos por una breve pausa La alarma se activa cuando el no break sistema UPS cambia a energia de bateria durante un apag n o caida de voltaje Importante Si las bater as estan muy desgastadas esta alarma sonar nuevamente y no podr ser silenciada para indicarle que los equipos conectados deben ser apagados inmediatamente Probar la carga de las bater as del no break sistema UPS Mantenga encendidos los equipos conectados Con el no break sistema UPS encendido ON y conectado a una toma de energ a el ctrica mueva este interruptor hacia la izquierda sost ngalo en esta posici n por 2 segundos y su ltelo El no break sistema UPS cambiar moment neamente a bater a para probar la carga de las mismas Si sonara la alarma del no break sistema UPS o los equipos conectados con demanda apropiada de energ a no fueran respaldados permita que el no break sistema UPS cargue sus bater as por un p
8. la bater a del No break o Sistema UPS mediante el interruptor MUTE TEST Silenciador Autoprueba para indicar que la bater a no est totalmente cargada Si esta luz contin a encendida comuniquese con Tripp Lite para obtener informaci n sobre el servicio de reparaciones Esta luz parpadear una vez que usted haya colocado el interruptor OFF ON Encendido Apagado en la posici n OFF Apagado para indicar que el No break o Sistema UPS no proporcionar energ a de respaldo durante un apag n o caida de voltaje Bas Cuando el no break est regulando autom ticamente el voltaje bajo o alto de entrada esta luz verde se iluminar y el no break emitir un leve sonido Cuanto m s irregular sea el voltaje de entrada m s se iluminar esta luz verde y m s sonidos emitir r el no break Estas son condiciones normales y autom ticas del no break y no requieren ninguna acci n de su parte S Otras Caracter sticas del Sistema UPS Recept culos de CORRIENTE ALTERNA Los recept culos proporcionan energ a de CA a los equipos conectados durante condiciones normales de operaci n Tambi n proporcionar n energia de bateria durante apagones y caidas de voltaje solamente si el interruptor OFF ON Encendido Apagado se coloca en la posici n ON Encendido Estos recept culos tambi n protegen sus equipos contra peligrosas sobretensiones transitorias y ruidos de l nea No obstante algunos modelos incluyen recept
9. lure of a Tripp Lite UPS System could cause failure or significantly alter the performance of a life support device e Do not connect surge suppressors to the output of your UPS This may damage your UPS and will void both the surge suppressor and UPS warranties Battery Warnings e Your UPS does not require routine maintenance Do not open your UPS for any reason There are no user serviceable parts inside e Battery replacement must be performed by qualified service personnel Because the batteries present a risk of electrical shock and burn from high short circuit current observe proper precautions Unplug and turn off the UPS before performing battery replacement Use tools with insulated handles and replace the existing batteries with the same number and type of new batteries Sealed Lead Acid Do not open the batteries Do not short or bridge the battery terminals with any object e The UPS batteries are recyclable Refer to local codes for disposal requirements or in the USA only call 1 800 SAV LEAD 1 800 728 5323 for complete recycling information Do not dispose of the batteries in a fire 2 Do not attempt to add external batteries Quick Installation D Plug your UPS into an electrical outlet Plug essential equip ment such as your computer monitor and modem into battery supported outlets Plug other equipment into surge only outlets Separate battery supported surge and surge only outlets are ide
10. nte de capacidad de recarga Servicio Si usted necesita enviar el sistema UPS al centro de servicio de Tripp Lite emp quelo cuidadosamente usando el MATERIAL ORIGINAL DE EMPAQUE incluido con la unidad Adjunte una carta describiendo los s ntomas del problema Si la unidad est dentro del periodo de garant a de 2 a os adjunte una copia de su factura original Especificaciones T cnicas OmniPro 500 Capacidad de Salida VA Watts 500 300 Tiempo de Respaldo Media Carga Plena Carga Minutos 17 5 Tiempo de Respaldo T pico Computadora y Monitor de 15 pulgadas Minutos 30 Tiempo de Recarga de la Bater a Horas 2 4 Certificaciones UL cUL NOM Protecci n Para M dem Fax Comienza a 260V 1 l nea Voltaje y Frecuencia de Entrada 120v 60Hz Gama de Voltaje de Entrada 98 140 volts Gama de Voltaje Regulado de Salida 120V 15 Gama de Voltaje de Salida en Bater a 120V 5 Tipo de Onda de Salida En L nea senoidal filtrada Tipo de Onda de Salida en Bater a Senoidal Modulada en Ancho de Pulso Supresi n de Picos de CA excede las normas de IEEE 587 Cat A y B Atenuaci n de Ruidos de CA gt 40 dB Modos de Protecci n L nea a Neutro L nea a Tierra Neutro a Tierra 93 1578 200003008 0300 Rev M 12
11. ntified on the back of your UPS Your UPS is designed to support only computer equipment You will overload your UPS if you connect household appliances laser printers or surge suppressors to the battery supported outlets Optional Installation Pr Using telephone cords connect your wall jack to the UPS jack marked LINE or IN Connect your equipment to the UPS jack marked EQUIP or OUT Phone line connections are optional Your UPS will function properly without these connections Make sure the equipment you connect to the UPS s telephone jacks is also protected against HHH damaging surges on the AC line H 4H a 3 Set your UPS s OFF ON Switch e Setto ON when you are using connected equipment e Set to OFF when you are not using connected equipment WARNING When set to OFF UPS will not provide battery backup duringa blackout or brownout See Basic Operation section for the Switch Function UPS Conditions and Setting Advantages Basic Operation Switches MUTE TEST With your UPS plugged in set this switch according to the recommendations in Step 3 of the Quick Installation section ON Position Function ENABLES battery backup UPS Conditions The UPS battery is charging Power is ON at the UPS receptacles The v indicator light is illuminated Setting Advantages
12. nual de operaci n contiene instrucciones y advertencias importantes que deben seguirse durante la instalaci n operaci n y almacenamiento del sistema UPS Tripp Lite Advertencias Sobre la Ubicaci n del Sistema UPS Instale este sistema UPS bajo techo en un lugar sin humedad o calor excesivo y sin polvo o luz solar directa Para obtener mejores resultados mantenga la temperatura ambiental entre O C y 40 C entre 32 F y 104 F Permita suficiente espacio alrededor de esta unidad para facilitar la ventilaci n apropiada de la misma Advertencias Sobre la Conexi n del Sistema UPS Conecte este sistema UPS a una toma de corriente de CA con conexi n a tierra de tres alambres No remueva o modifique la conexi n a tierra del enchufe del sistema UPS No conecte adaptadores de dos alambres al enchufe de este sistema UPS No conecte el enchufe del sistema UPS a sus propios recept culos esto da ar la unidad y anular su garant a Si usted desea conectar este sistema UPS a un generador del CA motorizado aseg rese que dicho generador proporcione energ a de salida limpia y filtrada Advertencias Sobre la Conexi n de Equipos No use sistemas UPS Tripp Lite en aplicaciones de soporte de la vida humana donde el una falla en la operaci n del sistema UPS Tripp Lite podr a causar fallas o alterar significativamente el funcionamiento de un dispositivo de soporte de la vida humana Las garant as de todos los supresores de s
13. obretensiones de Tripp Lite ser n anuladas si estos supresores han sido conectados a los recept culos de Salida de cualquier sistema UPS Las garant as de todos los Sistemas UPS de Tripp Lite ser n anuladas si se ha conectado alg n supresor de sobretensiones a los recept culos de salida del sistema UPS en cuesti n Advertencias Sobre la Bater a Este sistema UPS no requiere mantenimiento rutinario No abra el sistema UPS bajo ninguna circumstancia No hay partes que puedan ser reparadas por el usuario dentro de esta unidad El reemplazo de la bater a debe ser realizado por personal t cnico capacitado Deben obervarse todas las precauciones apropiadas ya que las bater as presentan riesgos de choques el ctricos y quemaduras por la alta corriente de cortocircuito Apague y desenchufe el sistema UPS antes de realizar el reemplazo de la bater a Use herramientas con asas aisladas y reemplace las bater as del sistema UPS con el mismo n mero y tipo de bater as nuevas Selladas de Plomo y Acido No abra las bater as No corte o conecte las teminales de la bater a con ning n objeto Las bater as de este sistema UPS son reciclables Refi rase al c digo local de requisitos para la disposici n de bater as No use fuego para disponer de las bater as No intente agregar bater as externas MEET o lle ELE Conecte el sistema UPS a una toma de corriente Conecte su computadora monitor y m dem externo a los recept culo
14. power capacity Service If returning your UPS to Tripp Lite please carefully pack the UPS using the ORIGINAL PACKING MATERIAL that came with the unit Enclose a letter describing the symptoms of the problem If the UPS is within the 2 year warranty period enclose a copy of your sales receipt Specifications OmniPro 500 Output Capacity VA Watts 500 300 Battery Runtime Half Load Full Load Minutes 17 5 Typical Runtime Desktop PC 15 in monitor Minutes 30 Battery Recharge Time Hours 2 4 Approvals UL cUL NOM Modem Fax Protection starts at 260V 1 line Input Voltage Frequency 120V 60 Hz On Line Input Voltage Range 98 140 volts Voltage Regulated Output Voltage Range 120V 5 On Battery Output Voltage Range 120V 5 Output Waveform Line Mode filtered sinewave Output Waveform Battery Mode PWM sine wave AC Surge Suppression exceeds IEEE 587 Cat A amp B standards AC Noise Attenuation gt 40 dB AC Protection Modes H to N H to G N to G Manual de Operacion OMNIPRO 500 TRIPP LITE POWER PROTECTION EE E No break Sistema UPS Chicago IL 60609 USA Interactivo 120V Servicios a Clientes US 773 869 1234 www tripplite com Seguridad Instalaci n R pida p 9 Operaci n B sica p 10 12 Almacenaje y Servicio p 12 Especificaciones p 12 Copyright 2000 Pr a Sa A Sees rvados todos los derechos Om registrada ei Tipo Lite Seguridad Este ma
15. s con energ a de respaldo Conecte otros equipos a los recept culos del sistema UPS con supresor de picos solamente Siel sistema UPS incluye recept culos separados con energ a de respaldo y recept culos con supresor de picos solamente identificados en la parte posterior del sistema UPS Este sistema UPS ha sido dise ado para respaldar equipos de computaci n Usted sobrecargar el sistema UPS si conecta dispositivos electrodom sticos impresoras l ser o supresores de picos a los recept culos con energ a de respaldo Instalaci n Opcional Utilizando cables telef nicos conecte el contacto del sistema UPS rotulado LINE l nea o IN entrada al contacto telef nico en la pared Conecte el equipo que desea proteger al contacto del sistema UPS rotulado EQUIP equipo o OUT salida Las conexiones telef nicas son opcionales El sistema UPS funcionar adecuadamente sin estas conexiones Aseg resequeel ii equipo conectado a los contactos telef nicos del sistema UPS HE tambi n est n protegidos contra peligrosos picos el ctricos en la l nea rH i re de CA 3 Posici n del Interruptor ON OFF Encendido Apagado de su No break o Sistema UPS e Mant ngalo en la posici n de encendido ON mientras usted est usando los equipos conectados e Mant ngalo en la posici n de apagado OFF cuando usted no est
16. t with AC line power during normal operation They will provide battery power during power failures only if the OFF ON Switch is set to the ON position The receptacles also protect your equipment against damaging surges and line noise Select models how ever feature surge only receptacles identified on the back of your UPS that provide the non essential peripherals plugged into the receptacles with surge protection without committing precious battery power to support them during power failures RJ11 Telephone Jacks mv mn These jacks protect your equipment against telephone line Fuld surges Connecting your equipment to these jacks is optional Your UPS will still work properly without this connection Battery Replacement Door Under normal conditions the original battery in your UPS will last several years Battery replacement should be performed only by qualified service personnel Refer to Battery Warnings in the Safety section on page 2 Storage amp Service Storage First turn your UPS OFF and disconnect all equipment Then disconnect its power cord from the wall outlet If you plan to store your UPS for an extended period of time fully recharge the UPS batteries once every three months by plugging the UPS into a live AC outlet and letting the UPS charge for 4 6 hours If you store your UPS without charging for an extended period of time its batteries will suffer a permanent loss of