Home

Trion Air Boss M-Series User's Manual

image

Contents

1. End Discharge Media and Adsorption Air Cleaner Dimensions M6000 Top View 1 00 59 63 Front View 13 87 Air Delivery M3000 ADDED STATIC PRESSURE IN 41 0 AIR FLOW 500 WL ADSORBER 1000 1500 Intake End 7 00 TYP INLET COLLAR OPTIONAL y i OPENING AIR FLOW ee ENG OF INLET 24 00 DRAIN OUTLET 1 12 DIA HOLE TYP 4 2 IN TOP 2 IN BOTTOM End Discharge EYE BOLTS FOR HANGING KIT OPTION A a ee ew AIR FLOW Mg El OPTIONAL HEPA MAIN BAG FILTER 4 PLEATED PREFILTER 72 00 2 62 M6000 4 PLEATED PREFILTER MIN 30 EFFICIENCY 36 LONG BAG FILTER 65 EFFICIENCY PRE FILTER 4 PLEATED PRIMARY FILTER 95 BAG T 12 HF gt B 5H P 3 50 BLOWER R H M ES L NOTE 1700 RPM MAXIMU sober steeo 7 ADDED STATIC INCHES OF WATER 2000 2500 3000 3500 O 1000 2000 3000 4000 5000 6000 7000 8000 CFM AIR DELIVERY IN CUBIC FEET PER MINUTE www trioninc com 3 Industrial Applications Guide Industrial Applications Dusts Smoke amp Fumes Process Finishings Manufacturing Process Atmospheric Burn Room Testing Exhaust Paint Room Make Up Air Spruce Cutting Effluent General Ventilation Metal Forming Plastic Molding Scrap Metal Pre heaters Tobacco Cold Headi
2. Prefilter amp Main Filter Drain M2500 No Drain Source Capture with Inlet Collar M3000 14 Dia or M6000 20 Dia with no Hole Dual Arm M3000 amp M6000 Only UL Listed Components Reduces Sound To 78 dBA www trioninc com 1 Media and Adsorption Air Cleaner Dimensions M2500 T re I Top View 185 gt ACCESS CLEARANCE a 2 1 37 2 KNOCK OUT LOCATIONS FOR SUSPENDED MOUNTING gt 6 l 239 8 25 0 AIR FLOW i va Y f ES j vA 6 ret L 125 ACCESS CLEARANCE Front View WRAP AROUND PREFILTER OPTIONAL ae H 23 6 eS E AIR FLOW AIR FLOW A AAA 46 8 3 GASKET 47 0 IBS 00 0 Dimensions M3000 Top View DIMENSIONS SHOWN LOCATING EYE BOLTS FOR HANGING KIT OPTION 59 188 L00 APSF 150 LESZ P QTY 4 DRAIN HOLES LOCATED 10 75 3 29 2 TOP AND 2 IN BOTTOM BS TP L JUNCTION BOX 112 DIA HOLES i i y iF 22 938 TYP AIR FLOW AIR FLOW STD sor soare Y Garewal So 62 OPTIONAL EITHER SIDE CLEARANCE Front View SOURCE CAPTURE 3 88 PLENUM OPTIONAL EYE BOLTS FOR HANGING KIT OPTION WRAP AROUND PLENUM OPTIONAL AIR FLOW STO AIR FLOW ql or A 2 www trioninc com Intake End 2225 6 00 IMIP A AA 1 00 50 2 00 22 25 2
3. Typical Heating amp Air Conditioning Systems 2 000 10 500 CFM Heavy ATS Electrostatic Equipment Application ene 250 600 CFM ome Mini Las Oil Mist Smoke Neo 300 800 CFM oe as Coolants 600 850 CFM Medium MP600M Media M A as 800 6 000 CFM Medium 1 300 4 500 CFM Medium 000 10 500 CFM Heavy T Series Electrostatic M Series Media ATS Electrostatic Oily Welding Fume Equipment 800 6 000 CFM Medium 1 200 4 500 CFM Medium 000 25 000 CFM Heavy 2 000 10 500 CFM Heavy T Series Electrostatic M Series Media Model 75 Electrostatic ATS Electrostatic Ambient Capture Free Hanging with Established Air Patterns a Industrial Dry Particulate Equipment 800 20 000 CFM Medium 000 25 000 CFM Heavy 8 250 Infinite CFM Heavy T Series Electrostatic Model 75 Electrostatic Model 60 Electrostatic Central System Typical Heating amp Air Conditioning Systems 2 000 10 500 CFM Heavy ATS Electrostatic Equipment 220 CFM Light One Man Portable Media 300 800 CFM Medium VOMP600 Electrostatic Application 600 850 CFM Medium MP600M Media ca Source Capture 900 1 100 CFM Light M2500M Media poner Using Hoods 900 1000 CFM Medium Port A Cart Cartridge ASS Arms Portable Units 800 6 000 CFM Medium 1 300 4 500 CFM Medium 1 800 4 500 CFM Heavy 400 80 000 CFM Heavy T Series Electrostatic M Series Media Air Boss Cartridge DC Series Cartridge Welding Fumes Smokes i Portable Unit Equipm
4. Forward Curved Belt Drive Backward Inclined Airfoil 3hp High Static 1300 2250 Motor Starter Optional 74 dBA O 5 Ft 4 Inch 35 Pleated Standard 2 Inch Aluminum Mesh Optional 2 Inch Impinger Optional 3 Way Wrap Around Optional 95 Bag Filter Standard 65 95 Extended Surface Optional 99 97 HEPA Optional 2 Ea Adsorber Modules Optional 25 Lbs Carbon Each 95 Short Bag Optional M6000 73 5 L x 49 W x 30 H 610 Lbs 700 Lbs 7 5 HP 208 240 480 60 3ph 19 8 9 9 AMPS 5hp 208 230 460 60 3ph 13 4 6 7 AMPS 5 HP 575 60 3ph 7 5 HP 575 60 3ph TEFC Ball Bearings 1740 RPM Standard 3450 RPM Optional Belt Drive Forward Curved N A 2400 4500 Motor Starter Optional 80 dBA 5 Ft 2 4 35 Pleated Standard 2 2 Aluminum Mesh Optional 2 2 Impinger Optional 2 95 Bag Filter Standard 2 65 95 Extended Surface Optional 2 99 97 HEPA Optional 4 Adsorber Modules Optional 25 Lbs Carbon Each 2 95 Short Bag Optional Manometer Or Magnehelic To Indicate When Filters Need Changing N A Specification for Each Unit Cabinet Finish Air Flow Filter Access Drain Plenum Agency Approvals Reduces Sound To 72 5 dBA 16 and 18 Gauge Galvanized Steel Blue Epoxy Powder Coat Horizontal Right to Left or Left to Right Optional Side Discharge M3000 amp M6000 Hinged Doors M3000 amp M6000 End Loading M2500
5. TRION Air Purification Systems Air Boss M Series Media amp Adsorption Air Cleaner Air Purification Systems www trioninc com Engineered Solutions For Clean Air Trion s Air Boss media units are industrial air cleaners designed for both general ventilation removal of airborne pollutants from plant atmospheres or source capture ductwork or arms positioned at the origin of pollutants These units help solve welding smoke oil mist rubber dust diesel smoke grinding dust numerous gases odors and many other indoor air pollution problems Features amp Benefits Straight Through or Side Discharge Ability to Better Control Airflow M3000 amp M6000 Odor and High Efficiency Filters From HEPA and Adsorber Modules to Mini Pleat Filters 194 388 Sq Ft for Maximum Efficiency and Effectiveness M3000 amp M6000 Belt Driven Blower with Variable Pitch Sheave Providing Adjustment for Precise CFM Operating Range M3000 amp M6000 Collects Wet or Dry Particulates Providing Versatility in a Wide Range of Applications M3000 amp M6000 High Static Blower Packages Capacity for Additional External Static Offers More Contaminant Pickup Points Optional For M3000 How it Works Trion s Air Boss Media Series uses the Interception Filtration Principle Dirty polluted air is drawn through the pre filter to remove larger dust particles The second stage micro glass deep poc
6. ent 800 6 000 CFM Medium 1 200 4 500 CFM Medium 000 25 000 CFM Heavy 2 000 10 500 CFM Heavy www trioninc com 5 T Series Electrostatic M Series Media Model 75 Electrostatic ATS Electrostatic Ambient Capture Free Hanging with Established Air Patterns m Our Media Air Cleaners come with a three year limited warranty Learn more about other Trion industrial products by contacting your local Mini M E ir Trion representative or by TRION visiting us on the web at www TRIONINC com Mini M E Mist Collector ij Trion 101 McNeill Road Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioninc com customerservice trioninc com 02 001 2M
7. ket media filter removes submicron particles from the air stream by interception The small diameter fibers in the filter intercept and retain these small particles while the large surface area of the filter gives long life and low pressure drop The blower is designed specifically to handle the filtration system at rated CFM over the useful life of the filter wwwW trioninc com Media Air Cleaning Process Dirty Air Y B m Clean Air Pre Filter Main Filter Air Boss M2500 M3000 M6000 Specifications Specifications Dimensions Installation Weight Electrical Standard Optional Motors Standard Blowers Standard Optional Air Volume CFM Controls Sound Rating Pre Filters Primary Secondary Gauge Kit Silencer Optional M2500 47 Lx 23 9 W x 23 6 H 180 Lbs Shipping 250 Lbs 75hp 120vac 60 1 ph 10 5 AMPS N A Thermally Protected Direct Drive Forward Curved N A 1240 2010 3 Speed Selector Switch 50 70 dBA 5 Ft 4 Inch 35 Pleated Standard Polyester Pad Optional 3 Way Wrap Around Optional 95 Bag Filter Standard 65 Bag Filter Optional N A M3000 68 L x 25 W x 26 25 H Suspended Wall or Frame Mounted 260 Lbs Shipping 330 Lbs 2 HP 208 240 480 60 3ph 5 8 2 9 AMPS 2 HP 575 60 3ph 3 HP 208 240 480 60 3ph 9 1 4 6 AMPS 3 HP 575 60 3ph TEFC Ball Bearings 1740 RPM Standard 3450 RPM Optional Belt Drive
8. ng Photo Industry Die Casting Rubber e Warm Fogging e Film Manufacturing Forming Shaping Silica Injection Molding e Photo Finishing Forging Plastic Epoxy Rubber Curing Fiberglass Drying Ovens Oil Mists Plasticizing Mica Heat Treating Metal Cutting Removal Forming Extruding Textile Indoor Firing Range Die Release Curing Dried Automotive Body Putty Kitchen Exhaust Extruding Sealing Talcum Powder Plasma Cutting Lubrication Hot Wire Cutting Paper Soldering e Gas Turbine Lub Vents Spices Tobacco Robotic Resistance Welders Toner Torch Cutting e Compressor Vents Wood light loadings Welding Carpet Backing Weaving Fly Ash Yarn Setting Texturizing Fluids Graphite Industrial Particulate Loading Guide A general guide to industrial particulate concentrations is as follows Light Dirty city air designated Medium Industrial process exhaust Heavy Metal machining oil mists smoking areas factory indoor air commercial grinding dusts heat treating 2 0 25 mg m kitchen exhaust operations heavy welding 25 100 mg m powders 100 mg m and above Particulate considerations such as conductivity tackiness and operation cycles need to be taken into consideration when determining equipment selections Industrial Applications Guide Industrial Wet Particulate Equipment 800 20 000 CFM Medium 2 000 25 000 CFM Heavy 8 250 Infinite CFM Heavy T Series Electrostatic Model 75 Electrostatic Model 60 Electrostatic Central System