Home
Traulsen RMC34 User's Manual
Contents
1. Quality Refrigeration OWNER S MANUAL Instructions for the installation operation and maintenance of Traulsen RMC Milk Cooler RMC34 RMC49 amp RMC58 Models This Traulsen unit is built to our highest quality standards We build our refrigerators and freezers this way as a matter of pride This philosophy has made Traulsen the leader in commercial refrigeration since 1938 We thank you for your choice and con fidence in Traulsen equipment and we know you will receive many years of utility from this equipment All Traulsen units are placed on a permanent record file with the service department In the event of any future questions you may have please refer to the model and serial number found on the name tag affixed to the unit Should you need service call us on our toll free number 800 825 8220 between 7 30 am 4 30 pm CST Monday thru Friday You may also log onto www traulsen com for further information It is our pleasure to help and assist you in every possible way INSTALLER COMPLETE THE FOLLOWING INFORMATION PRIOR TO UNIT INSTALLATION INITIAL START DATE SERIAL NO MODEL TYPE COMPANY INDIVIDUAL NAME INSTALLER FORM NUMBER TR35944 REV 02 04 14 P N 375 60324 00 THE SERIAL TAG Il RECEIPT INSPECTION Ill INSTALLATION a Location b Packaging c Installing Adjusting the Casters d Cord amp Plug e Power Supply IV OPERATION a Temperature Control V CARE amp MAINTENANCE a Cleaning The Condense
2. ll RECEIPT INSPECTION All Traulsen products are factory tested for performance and are free from defects when shipped The utmost care has been taken in crating this product to protect against damage in transit You should carefully inspect your unit for damage during delivery If damage is detected you should save all the crating materials and make note on the carrier s Bill Of Lading describing the damage A freight claim should be filed immediately If damage is subsequently noted dur ing or immediately after installation contact our customer care team to file a freight claim There is a fifteen 15 day limit to file freight damage with the carrier Under no condition may a damaged unit be returned to Traulsen without first obtaining written permission return autho rization You may contact Hobart Traulsen customer care at 800 333 7447 to request a return or file a claim Ill INSTALLATION Ill a LOCATION Select a proper location for your unit away from extreme heat or cold Ill b PACKAGING Your Traulsen unit is shipped from the factory bolted to a sturdy wooden pallet in stretch wrapped material Most exterior stainless steel surfaces have a protective vinyl covering to prevent scratching during manufactur ing shipping and installation After the unit is installed in place of application peel remove and discard the covering from all surfaces To remove the wooden pallet first if at all possible we suggest
3. that the cabinet remain bolted to the pallet dur ing all transportation to the point of final installation The bolts can then be removed with a 1 2 socket wrench Avoid laying the unit on its back for removal of the pallet NOTE Traulsen does not recommend laying the unit on its back If you must please allow the unit to re main in an upright position for 24 hours before plug ging it in so that the compressor oils and refrigerant may settle Il c INSTALLING ADJUSTING LEGS OR CASTERS Casters are installed at the factory but will require adjust ment upon installation To adjust the legs or casters loosen the two bolts and move leg or caster to desired location spacing between leg or caster not to exceed 48 inches Leg or caster on each end of the unit can not exceed 8 inches from the end of the cabinet Ill INSTALLATION continued Ill c INSTALLING ADJUSTING LEGS OR CASTERS Channel Caster Plate Caster Ill d CORD 4 PLUG All self contained models are shipped standard with a NEMA 5 15P plug and 9 foot cord Select only a dedicated electrical outlet for power source NOTE Do not under any circumstances cut or remove the round grounding prong from the plug or use an extension cord Ill e POWER SUPPLY The supply voltage should be checked prior to connection to be certain that proper voltage for the cabinet wiring is available refer to the serial tag to determine correct unit voltage see p
4. K OOOO o SER058800 e ADJUSTABLECASTERWITHLOCK osa or 4 ADJUSTABLECASTERNOLOCK SER 6053600 4 ADJUSTABLECASTERWITHLOCK rosa Or e Tate mos eus SER088 00 Doon wop smMos O o TOP DOOR ASSEMBLY OOOO O OOOO oo FRONT DOOR ASSEMBLY O O O 200608909 wowismwo O EN roepooRassEMBE OOOO OOO OO o 200 60899 00 FRONTDOORASSEMBLy O O 200 6089 01 wo smwo TOP DOOR ASSEMB OOOO OOO OoOO ooa FRONT DOOR ASSEMBLY 200 6089 05 eas erToPDOORRMCRA OO 8416026700 eas erToPbooRRMc4g O O O O faeo eas erToPboORRMCSS 8416026702 GASKETFFRONTDOORRMC amp A O O 841 60262 00 easken FrontDoor Rmo 8416026201 eas errmoNrboORRMCSS 8416026202 fesker systemom EXEC easier SYSTEM AM O 84160268 01 A EGSA OO O 841 60268 02 IN CA ETT IN CTI E IN CET ETT IN CET 0 10280 07 IN CO ETT IN CIT 409 180 086 200 FLOOR RACKS ALL MODELS CYS FLOOR RARA ora mos Am 058 O Troon rack O O OOOO O O o o or ARDUCT mooersrmesa O O ooo C ARDUCTASSEMBLY oo wopksmMCAp amp RMOS Jai DUCT ASSEMBLY ENANA ona
5. OTE Compressor may be cycling ON OFF door was kept open for a long period of time frequently c Clean Condenser 4 Food Compartment is too cold a Check if a large quantity of very cold or frozen food has recently been added Allow adequate time for the cabinet to recover its nor mal operating temperature 5 Condensation on exterior surface a Check door s alignment and gaskets for proper seal b Condensation on the exterior surface of the unit is perfectly nor mal during periods of high humidity 6 Compressor hums amp does not start a Call for service Vil SERVICE ASSISTANCE VII a SERVICE CHECK LIST Before calling for service please check the following Is the electrical cord plugged in Is the fuse OK or circuit breaker on Clean condenser coil Is the power switch on If after checking the above items and the unit is still not operating properly please contact an authorized Traulsen service agent A complete list of authorized service agents was provided along with your Traulsen unit If you cannot locate this you may also obtain the name of a service agent from the Tech Service page at traulsen com If service is not satisfactory please contact our in house service department at Traulsen 4401 Blue Mound Road Fort Worth TX 76106 800 825 8220 Traulsen reserves the right to change specifications or discontinue models without notice VII b SERVICE INFORMATION To purchase replacement parts or to s
6. age 1 Make connections in accordance with local electrical codes Use qualified electricians Use of a separate dedicated circuit is required Size wiring to handle indicated load and provide necessary over current protec tor in circuit see amperage requirements on the unit s serial tag IV OPERATION IV a TEMPERATURE CONTROL The temperature is set at the factory but local conditions may necessitate slight adjustment The temperature control is located behind the silver plug on the front side of the system area dial thermometer side To adjust remove the plug turn the adjustment screw with a pair of pliers a small amount at a time turning clockwise lowers the tempera ture An OFF position is fully counterclockwise and interrupts power to the compressor and condenser fan only not the entire refrigerator 2 IV OPERATION continued IV a TEMPERATURE CONTROL continued Colder Temperature Adjustment Shaft V CARE amp MAINTENANCE V a CLEANING THE CONDENSER FILTER The most important thing you can do to insure a long reliable service life for your Traulsen is to regularly clean the condenser coil and or filter WARNING DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING ANY PARTS OF THE UNIT To clean the condenser filter first disconnect electrical power to the cabinet and remove the system side cover Proceed to vacuum or brush any dirt lint or dust from the finned conde
7. food loss TRAULSEN S standard warranty does not apply to Export Sales Rather for a period of one 1 year from date of original installation not to exceed Fifteen 15 months from date of shipment from factory TRAULSEN will at Traulsen s sole discretion replace or repair F O B factory any defective parts normally subject to warranty and will not cover the cost of packing freight or labor such costs being the sole responsibility of the dealer THERE ARE NO ORAL STATUTORY OR IMPLIED WARRANTIES APPLICABLE TO TRAULSEN INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF TRAULSEN SHALL HAVE NO OBLIGATION OR LIABILITY FOR CONSEQUENTIAL OR SPECIAL DAMAGES INCLUDING BUT NOT LIMITED TO INDIRECT PUNITIVE DAMAGES LOSS OF USE LOSS OF PRODUCT DOWN TIME OR LOST PROFITS GROWING OUT OF OR WITH RESPECT TO THE EQUIPMENT OR ITS SALE OPERATION OR USE AND TRAULSEN NEITHER ASSUMES NOR AUTHORIZES ANYONE ELSE TO ASSUME FOR IT ANY OBLIGATION OR LIABILITY IN CONNECTION WITH THE EQUIPMENT OR ITS SALE OPERATION OR USE OTHER THAN AS STATED HEREIN THIS WARRANTY IS IN LIEU OF ALL OTHER WARRANTIES EITHER EXPRESSED OR IMPLIED AND CONSTITUTES TRAULSEN S FULL OBLIGATION AND LIABILITY WARRANTIES NOT AVAILABLE ON REMOTE MODELS 6 X SERVICE PARTS LIST casten ALE MODELS O o amp ADJUSTABLECASTERNOLOO
8. n ALE MODELS O O sroeeR a EST X SERVICE PARTS LIST continued REF SYSTEM MODELS RMO348 REPLACEMENT REFRIGERATION SYSTEM SINGLE ACCESS SER6061700 mom m3 REPLACEMENT REFRIGERATION SYSTEM DUAL ACCESS SER eoero mot m4 REPLACEMENT REFRIGERATION SYSTEM SINGLE ACCESS SEF 6061800 wopismWcgD REPLACEMENT REFRIGERATION SYSTEM DUALACCESS SER 6001s 01 mom Ames O REPLACEMENT REFRIGERATION SYSTEM SINGLE ACCESS SER6061900 wopismwcsD REPLACEMENT REFRIGERATION SYSTEM DUALACCESS SERe0619 01 CONTROL ALL MODELS o MIROPROCESSORCONTROL O rason MICROPROCESSOR COIL TEMPERATURE SENSOR 88 60447 00 MICROPROCESSOR CABINET TEMPERATURE SENSOR 637 6044800 THERMO METER DIAL feos NOTE Part numbers listed are for standard products as currently manufactured For products manufactured as other than standard please contact the factory HOURS OF OPERATION Monday thru Friday 7 30 am 4 30 pm CST Traulsen 4401 Blue Mound Road Fort Worth TX 76106 Phone 800 825 8220 Fax 817 740 6757 traulsen com Quality Refrigeration 2014 Traulsen All Rights Reserved
9. ne such as bleach this may promote corrosion of the stainless steel Care should also be taken to avoid splashing the unit with water containing chlorinated cleansers when mopping the floor around the unit For stubborn odor or spills use baking soda and water mixed to a 1 tbsp baking soda to 1 pint water ratio A stainless steel polish is recommended for shining of unit The unit is equipped with a drain for cleaning the inside of the unit VI WIRING DIAGRAM NOTE Refer to the wiring diagram below for any service work performed by a qualified technician JOLIIVIVI Lavls JOSSIAANOI NVJ JISNIANOI JAWA GIDN3 IDS AWO 831009 AIN 8S Y 6v WNOILdD NYJ JOLVIDIVAI 4371009 IN BS 6r pE AJVHIJA NVI YOLVIDIVAI Jn 1 MOSN3S 1109 zS 9 S y 2 L NDSN3S ALIAVO IS WALNOD SSD3NVG E we JLIHA HdT1 2H09 2VASTT 43 1009 TIW WV3DVIG DNIJIA a Asda 00 8 ES09 6 HAT ZHO9 IVASTT JIADA AlddNS 4 VII TROUBLE SHOOTING GUIDE PROBLEM POSSIBLE SOLUTION 1 Condensing unit fails to start Check if cord amp plug has been disconnected Clean Condenser 2 Condensing unit operates for prolonged Are doors closed properly periods or continuously Dirty condenser or filter Clean properly Evaporator coils iced Needs to defrost 3 Food Compartment is too warm Check door s and gasket s for proper seal Check if a large quantity of warm food was recently added or the N
10. nser coil filter the compressor and other cooling system parts If significant dirt is clogging the condenser fins or filter use compressed air to blow this clear To replace the system side cover reverse the process V b REPLACING THE DOOR GASKETS To remove the gasket to be replaced grasp it firmly by one corner and pull it out Before attempting to install a new gasket both the unit and the gasket itself must be at room temperature Insert the four corners first by using a rubber mallet or hammer with a block of wood After the corners are properly inserted work your way towards the center from both ends by gently hitting with a mallet until the gasket is completely seated in place see figure below for proper gasket placement NOTE The gasket may appear too large but if it is installed as indicated above it will slip into place Front Door Gasket NOTE System gasket attached with screw V CARE amp MAINTENANCE continued V b REPLACING THE DOOR GASKETS Top Door Gasket V c CLEANING THE CABINET SURFACES WARNING DISCONNECT ELECTRICAL POWER SUPPLY BEFORE CLEANING ANY PARTS OF THE UNIT Exterior stainless steel should be cleaned with warm wa ter mild soap and a soft cloth Apply with a dampened cloth and wipe in the direction of the metal grain Avoid the use of strong detergents and gritty abrasive cleaners as they may tend to mar and scratch the sur face Do NOT use cleansers containing chlori
11. peak to service support for Traulsen and most Hobart Refrigeration units please contact our Ft Worth facility by phone at 800 825 8220 or fax to 817 740 6748 parts or 817 740 6757 service To obtain other service informaiton you may log onto 1 traulsen com 2 Select Service amp Parts Tab upper right of screen 3 Select one of the following Service Finder Service Parts Manuals Parts Pricing amp Warranty Registration NOTE When calling for service support please make sure you have model and serial number of unit available 5 IX WARRANTIES STANDARD DOMESTIC WARRANTY TRAULSEN warrants new equipment to the original purchaser when installed within the United States against defective material and workmanship for three 3 years from the date of original installation Under this warranty TRAULSEN will repair or replace at its option including service and labor all parts found to be defective and subject to this warranty Warranty term begins upon the date of Installation the date of End User Invoice or the date of Dealer Invoice whichever is proven to occur latest not to exceed 18 months from Dealer Invoice date the Warranty Period Warranty excludes components that are removable without tools The compressor part is warranted for an additional two 2 years During this period TRAULSEN will supply replacement compressor s if deemed defective however all installation recharging and repair costs will remain the re
12. r Filter b Replacing The Door Gaskets c Cleaning The Cabinet Surface VI WIRING DIAGRAM VII TROUBLE SHOOTING GUIDE VIII SERVICE ASSISTANCE a Service Check List b Service Information IX WARRANTIES X SERVICE PARTS LIST arm FORT WORTH TX SERIAL VOLTS Hz TOTAL CURRENT AMPS MINIMUM CIRCUIT AMPS MAXIMUM OVERCURRENT PROTECTION LIGHTS WATTS HEATERS AMPS REFRIGERANT DESIGN PRESSURE TYPE HIGH REFRIGERANT DESIGN PRESSURE TYPE HIGH 370 60294 00 REV A NSF MODEL PH Page 1 Page 2 Page 2 Page 2 Page 2 Page 2 Page 2 Page 2 Page 3 Page 3 Page 3 Page 4 Page 5 Page 5 Page 5 Page 6 Page 7 8 TABLE OF CONTENTS l THE SERIAL TAG The serial tag is a permanently affixed label on which is recorded vital electrical and refrigeration data about your Traulsen product as well as the model and serial number This tag is located in the left interior compartment on all standard milk cooler models READING THE SERIAL TAG e Serial The permanent ID of your Traulsen unit e Model The model of your Traulsen unit e Volts Voltage e Hz Cycle e PH Phase e Total Current Maximum amp draw e Minimum Circuit Minimum circuit ampacity e Lights Light wattage e Heaters Heater amperage Hot Food units only e Refrigerant Refrigerant type used e Design Pressure High amp low side operating pressures and refrigerant charge e Agency Labels Designates agency listings
13. sponsibility of the owner This warranty does not apply to damage resulting from fire water burglary accident abuse misuse transit acts of God terrorism attempted repairs improper installation by unauthorized persons and does not apply to food loss For Traulsen units purchased with a remote feature standard warranty will apply only to those components contained within the unit to the point of connection of the refrigeration lines leading to the remote condenser Defective Part Return All claimed defective replacement part s must be returned to TRAULSEN for inspection within 30 days from the date of the repair Failure to return all claimed defective part s to TRAULSEN will invalidate the warranty claim this warranty statement and forfeit payment for those repairs affected INTERNATIONAL COMMERCIAL WARRANTY TRAULSEN warrants to the original purchaser the Refrigeration Equipment shall be manufactured free from defects in material and workmanship under normal use and service for a period of one 1 year from date of shipment Under this warranty TRAULSEN will reimburse the purchaser for the replacement of any part of said equipment excluding dryers amp refrigerant gas which then proves to be defective This warranty does not apply to damage resulting from fire water burglary accident abuse misuse transit acts of God terrorism attempted repairs improper installation by unauthorized persons and will not apply to