1.      Model  N FX xx 02 and N FX xx 02 L  Network Interface Cards  Part Number  N FX ST 02 x   N FX SC 02 x   N FX LC 02 x     Regulation     Purpose  To declare that the N FX xx 02 and N FX xx 02 L   to which    CISPR 22 1997 A1 2000  EN 55022 1998 A 1 2000 Class A  FCC Part 15 Subpart B   21CFR subpart J    I  the undersigned  hereby declare that the equipment specified above conforms to the above Directive s     ANSTTION Declaration of Conformity    Minneapolis  MN 55344 U S A    N FX MT 02 x   N FX SC5 02 x   N FX SC20 02 x    N FX SB201 02 x   N FX SB202 02 x    EMC Directive 89 336 EEC    this declaration refers  is in conformity with the following  standards        and Standard s    Aap Ae June 30  2005  Stephen Anderson  Vice President of Engineering Date             Tech Support  1 800 260 1312 International  00 1 952 941 7600  24 hours       Contact Us    Technical support  Technical support is available at techsupport transition com       US and Canada  1 800 260 1312  24 hours   e International  00 1 952 941 7600  24 hours     Transition now  Chat live via the Web with Transition Networks Technical Support  Log onto  www transition com and click the Transition Now link    Web based seminar  Transition networks provides seminars via live  web based training  Log onto  www transition com and click the Learning Center link    Email  Ask a question anytime by sending an email to our technical support staff   techsupport transition com   Address  Transition Networks    
2.   distance is dependent upon the physical Cable Specifications             4  characteristics of the network installation  Technical Specifications          5  Troubleshooting                 6  Contact US  iscir eee aaeieas 7                N FX Series Fast Ethernet NICs       Installation  Checklist    Before installing the N FX module  verify that the package contains the following  items     e N FX module  e LAN driver CD    Please notify your sales representative if any item is missing or damaged     Description    The N FX module has a bootable ROM socket  ROM chip sold separately   The  two LED indicators  LINK ACT and FDX located on the bracket  show  network board link  activities  collision  and full duplex statuses  See Figure 1            Figure 1  LEDs and Boot ROM Socket    N FX module installation    CAUTION  Wear a grounding strap and observe electrostatic discharge  precautions when installing the N FX module  Failure to observe this caution  could result in damage or failure of the N FX module     To install the N FX module  do the following   Important  Install the N FX module in a    master slot    only   Locate a master slot on the PC workstation or file server   Remove the cover from the PC workstation or file server   keep all screws     1  2  3  Remove and keep the screws holding the cover over the installation slot   4    Carefully slide the N FX module into the    master slot     aligning the  module with the slot guides        Tech Support  1 800 26
3. 0 1312 International  00 1 952 941 7600  24 hours       Install the N FX module    continued    5  Ensure that the module is firmly seated in the slot     6  Use the screws from step    3    to secure the module to the workstation or  file server housing     N FX PCI module configuration    For motherboards with automatic PCI configuration    e No specific setup is needed    e You can enter the system BIOS setup menu to view or specify the interrupt   INT  line of the PCI slots    For motherboards with bus master and interrupt jumpers    e Enable bus master operation in a selected PCI slot and select an INT  request line  IRQ  level  using the appropriate motherboard jumper    e Enable I O on the N FX  PCI slot     PCI bus system and configuration    e Ensure that the PCI machine supports master slots  and INT multiple  sharing and timing compatibility    e DO NOT install N FX in PCI slave slots  Please refer to your PC system  manual and select the appropriate configuration settings     e When installing multiple N FX modules in a server station  you should  correctly configure the IRQ settings of the PCI slot    e Up to four N FX modules can be installed in a PCI file server running  NetWare operating system    e  N FX server modules share the same INT line with the driver supporting  multiple INT services at a time  The IRQ of each N FX module should not  conflict with other boards    e Operation in full or half duplex  default  mode is configured by LAN  driver options  T
4. 550 TX 1310 RX nm single mode   single stand  min   14 0 dBm max   8 0 dBm  min   32 0 dBm max  0 0 dBm  18 0 dB    The fiber optic transmitters on the device meet Class I Laser safety requirements  per IEC 825 CDRH standard and comply with 21CRF1040 10 and    21CRF1040 11           Tech Support  1 800 260 1312 International  00 1 952 941 7600  24 hours    Technical Specifications  For models N FX xx 02 and N FX xx 02 L     Standards    Expansion bus standard   Data rate   LED     Drivers     Boot server support   PCB dimensions     Weight    Power consumption   MTBF   Opearting temp   Storage temp   Humidity    Altitude    Warranty     IEEE 802 3   PCI 2 1  2 2   100Mbps fiber media   LINK ACT  on the bracket    ON   communication link  FLASHING   activity  on link   FDX  full duplex link   ON   full duplex link     Windows 95  98  ME  2000  2003  XP  NT4 0  e NDIS 2  3  4  5   e NetWare Server 3 12  4 x  5x  6 x   e Netware DOS Client ODI   e MAC OS   e Linux x86  AMD64   e FreeBSD 3 2  4 x  5 x   e SOC Unixware 7 1  OpenUnix 8   e SCO Open Server 5 0 x   e Solaris 8  9  10   PXE  RPL  Netware NCP IPX  DHCP  BootP  2 2   W x 4 8   D x 0 9   H    55 9 mm x 121 9 mm x 23 mm    3 oz   91g  approximate   1 0A    5VDC   184 743 hours  Bellcore7 V5 0    0  C to 50  C  32  F to 122  F     25  C to 85  C   13  C to 185  F    5  to 90   non condensing   0 to 10 000 feet   Lifetime    WARNING  Visible and invisible laser radiation when open  DO NOT stare into  the beam or view direct
5. 6475 City West Parkway  Minneapolis  MN 55344  U S A     Telephone  952 941 7600   Toll free  800 526 9267  Fax  952 941 2322       techsupport transition com    Click the    Transition Now    link for live Web chat        Compliance Information    CISPR22 EN55022 Class A  CE Mark  CISPR22 EN55022 Class A   EN55024  CE Mark    FCC regulations   This equipment has been tested and found to comply with the limits for a Class A digital device   pursuant to part 15 of the FCC rules  These limits are designed to provide reasonable protection  against harmful interference when the equipment is operated in a commercial environment  This  equipment generates  uses  and can radiate radio frequency energy and  if not installed and used in  accordance with the instruction manual  may cause harmful interference to radio communications   Operation of this equipment in a residential area is likely to cause harmful interference  in which  case the user will be required to correct the interference at the user s own expense     Canadian regulations   This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out  on the radio interference regulations of the Canadian Department of Communications    Le pr  sent appareil num  rique n   met pas de bruits radio  lectriques d  passant les limites applicables  aux appareils num  riques de la Class A prescrites dans le R  glement sur le brouillage  radio  lectrique   dict   par le minist  re des Communications 
6. TRANSITION    a networks       USER   S GUIDE    N FX xx 02  standard   N FX xx 02 L   low profile     100Base FX  Fast Ethernet Fiber NICs    Transition Networks    N FX series of fast  Ethernet NICs  Network Interface Cards   provide a 100Base FX fiber port to deliver  low cost fiber optic connectivity to the desktop  in fiber rich LAN environments  With both  standard and low profile form factors  driver  support for most operating systems  and PCI  2 2 plug and play capability  these fast Ethernet NICs can be installed in virtually                                     Part Number Port One   Duplex Fiber Optic 100Base FX  N FX ST 02 ST  1300 nm multimode  2 km  1 2 miles    N FX ST 02 L    N FX SC 02 SC  1300 nm multimode  2 km  1 2 miles    N FX SC 02 L    N FX LC 02 LC  1300 nm multimode  2 km  1 2 miles    N FX LC 02 L    N FX MT 02 MT RJ  1300 nm multimode  2 km  1 2 miles    N FX MT 02 L    N FX SC5 02 SC  1310 nm single mode  5 km  3  Jmiles    N FX SC5 02 L    N FX SC20 02 SC  1310 nm single mode  20 km  12 4 miles    N FX SC20 02 L    N FX SB201 02 SC  1310 TX 1550nm RX single mode  single fiber 20 km  N FX SB201 02 L   12 4 miles     N FX SB202 02 SC  1550 TX 1310 nm RX single mode  single fiber 20 km  N FX SB202 02 L   12 4 miles     Optional accessories sold separately   Part Number Description   BTR NFX Boot ROM chip supports BBS  Bios Boot specification  and    non BSS compliant PCs            Typical maximum cable distance  Actual Installation se es aanne aa 2
7. du Canada     European regulations    Caution  This is a Class A product  In a domestic environment this product may cause radio  interference in which case the user may be required to take adequate measures    Achtung  Dieses ist ein Ger  t der Funkst  rgrenzwertklasse A  In Wohnbereichen k  nnen bei  Betrieb dieses Ger  tes Rundfunkst  rungen auftreten  In diesem Fall ist der Benutzer fiir  Gegenmafinahmen verantwortlich     Attention  Ceci est un produit de Classe A  Dans un environment domestique  ce produit risque de  cr  er des interf  rences radio  lectriques  il appartiendra alors    l utilsateur de prende les measures  sp  cifiques approprices     and of the Council of 27 January 2003  Transition Networks will accept post usage  returns of this product for proper disposal  The contact information for this activity can be  E found in the  Contact Us  portion of this document     Dat In accordance with European Union Directive 2002 96 EC of the European Parliament    CAUTION  RJ connectors are NOT INTENDED FOR CONNECTION TO THE  PUBLIC TELEPHONE NETWORK  Failure to observe this caution could result in  damage to the public telephone network   Der Anschluss dieses Ger  tes an ein 6ffentlickes Telekommunikationsnetz in den EG   Mitgliedstaaten verst  sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der  Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten tiber  Telekommunikationsendeinrichtungen einschliesslich der gegenseitige
8. he operating mode should match the working status of the  remote link device    e Use EMM386 version 4 49 or higher  and install both DOS and EMM386  from the same DOS package to avoid software problems        techsupport transition com    Click the    Transition Now    link for a live Web Chat  3    N FX Series Fast Ethernet NICs       Cable Specifications    Fiber cable    Bit error rate    Single mode fiber  recommended    Multimode fiber  recommended    Multimode fiber  optional       lt 10 9   9 um   62 5 125 um   100 140  85 140  50 125 um    N FX ST 02 x   N FX SC 02 x   N FX LC 02 x   N FX MT 02 x     Fiber optic transmitter power   Fiber optic receiver sensitivity   Link budget     N FX SC5 02 x    Fiber optic transmitter power   Fiber optic receiver sensitivity   Link budget     N FX SC20 02 x    Fiber optic transmitter power   Fiber optic receiver sensitivity   Link budget     N FX SB201 02 x     Fiber optic transmitter power   Fiber optic receiver sensitivity   Link budget     N FX SB202 02 x   Fiber optic transmitter power     Fiber optic receiver sensitivity   Link budget     1300 nm multimode  min   19 0 dBm max   14 0 dBm  min   31 0 dBm max   17 0 dBm  12 0 dB    1310 nm single mode  min   19 0 dBm max   14 0 dBm  min   31 0 dBm max   7 5 dBm  12 0 dB    1310 nm single mode  min   15 0 dBm max   8 0 dBm  min   31 0 dBm max  0 0 dBm  16 0 dB    1310 TX 1550 RX nm single mode   single stand  min   14 0dBm max   8 0 dBm  min   32 0 dBm max  0 0 dBm  18 0 dB    1
9. ly with optical instruments  Failure to observe this warning  could result in damage to your vision or blindness     CAUTION  Use of controls  adjustments  or the performance of procedures other  than those specified herein may result in hazardous radiation exposure     The information in this manual is subject to change without further notice        techsupport transition com    Click the    Transition Now    link for live Web chat  5    N FX Series Fast Ethernet NICs       Troubleshooting    D    iagnostics LEDs and Boot ROM  LEDS    The LINK ACT LED lights when a fiber cable or twisted pair cable connection  is good  It blinks to indicate activity     The collision and full duplex LED report board operating status   Boot ROM    To add the remote boot feature to a workstation  insert the Boot ROM into the  ROM socket  See Figure   on page 2     After power UP  the LINK ACT LED should light  if not  check the following   1 Confirm that the N FX module is properly inserted into the master slot     2 Confirm that the PC is properly connected to a power source and with the  power source turned ON     3 Check the fiber cable for proper connection     4 Contact Tech Support  1 800 260 1312  Int   l  00 1 952 941 7600 if those  steps fail to produce the desired result     Note  To connect this device to a router  bridge  or switch  please refer to the  corresponding technical manual for the device           R    Ci networks  Name of Mfg  Transition Networks  6475 City West Parkway
10. n Anerkennung ihrer  Konformitat     Trademark notice  All registered trademarks and trademarks are the property of their respective owners     Copyright restrictions     2004 2005 Transition Networks  All rights reserved  No part of this work may be reproduced or  used in any form or by any means   graphic  electronic or mechanical   without written permission  from Transition Networks       Printed in the U S A  Manual Part Number and Rev  33338 B    
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Blue&Me-TomTom  Philips 32PFL4609 31.5" HD-ready Smart TV Wi-Fi Black  Documentação e comunicação no trabalho com HIV  東芝メタルハライ ドランプ 量喜篁善吾吾ド 取扱説明書  TWISTER User Manual  Manual de instrucciones HIDROMASAJE PARA PIES  MANUEL D`UTILISATION DE L`ANALYSEUR GD5000  JL05 - JAE    Belkin F8V3280AEA2    Copyright © All rights reserved. 