Transition Networks SDSFE31XX-100 User's Manual
Contents
1. 28 29 software tree 25 system info SUDMEeNU cococoococococcnonocononanncnnononononnnononaos 26 user name password display erreese 3 Hardware VersiON coooonocnoniocononmmosmmmso 26 Installation DB Cable ora dt 18 Device Server un een 8 device server to DIN rail oooooioononocinnnonnoconononnos 9 DIN Halter elektr 9 iberica ca iaa 17 redirector software esessssesnesesnenesnesennennenennnnennnene 46 what to consider niniin ai 8 where to install esse 8 IP Traps how to configure u 40 Manager anne 39 parameters and descriptions errwesee 39 LEDs where located and descriptions neeeee 22 Loging In WED Suede 23 Operation configuration software ooooococionococnnncononononnonocnonannonos 25 LEDs where located and descriptions ommmoo 22 serial IP redirector software 44 web access configuration 23 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 73 Transition Networks Packet Mode input and timeout values 29 Parts FUNCION Sia 4 5 Power howto wire dicas 13 primary redundant esesesesesesesesnenesnenennenennen 12 terminal blocks ns 12 terminal block location wweenrene 12 terminal block plug Wiring ocooninoonmommmmmo 13 Redirector Software CONTE Wizard ada 44 control Panel einen 5 creating COM ports 51 52 how tol
2. DIN Rail Clip Back View Figure 3 Mounted DIN Rail Clip DIN rail and Consider the following before mounting the DIN rail to a surface and attaching the device server Device Server mounting e The surface must support at least 1 000 gm 2 2 bs for the Device Server considerations e Do not place heavy objects on the Device Server A CAUTION Mount the Device Server with proper spacing around it for ventilation heat dissipation Failure to observe this caution could result in damage to the Device Server A CAUTION Please exercise caution when using power tools Do not install this unit in damp or wet locations or in close proximity to very hot surfaces Failure to observe this caution could result in damage to the Device Server and cables Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 9 Transition Networks SDSFE31xx 100 Industrial Device Server DIN rail clip and DIN rail mounting continued Mounting the To mount the Device Server to the DIN rail see Figure 4 and do the following device server Align and then position DIN Rail clip spring to the top of the DIN rail as shown in Figure 4a 2 Press DOWN on the Device Server and then IN to snap it into place on the DIN Rail See Figure 4b b Metal Metal Spring Spring DIN Rail DIN Rail Correct Installation Figure 4 Device Server Mounting to DIN Rail 10 24 Hour Technical Support 1 800 2
3. and password if previously set See Figure 55 SenalflP Control Panel x Configuration of COM IF Address Port Humber I Connect to server 192 168 0 254 1234 Accept Connections Configuration Wizard User Credentials W Use Credentials From Use Credentials Below Username todd SE Eopy Settings GA COM Port Options FT DSR Emulation T DED Emulation CTS Emulation DTR is modem escape Restore Failed Connections Select Ports Port Monitor Licensing HEE Advanced Help About Figure 55 Virtual Port Configuration Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 53 Transition Networks SDSFE31xx 100 Industrial Device Server Creating virtual COM ports continued Click the CONFIGURATION WIZARD button to bring up the configuration wizard shown in Figure 56 2 Configuration Wizard COM IF Address of Server Fort Humber i 92 168 0 254 i 234 Username Password Test for presence of a modem connected to the server Status Log E Use settings D Stop ET Cancel eo Figure 56 COM Port 7 Configuration Wizard 8 If any of the settings are incorrect change them Click the START button Note as the wizard runs the status panel will show a summary of server characteristics The log panel shows the w
4. AN U SDSFE31xx 100 RS 232 to 100Base FX Industrial Device Server Manual 33367 Rev A Transition Networks Table of Contents FEB WANNE nao v CEON ee e r a A A v About his Product ANA mama ei es ee vi Dove Sy nee ee ae ee ea vi alea A a ee este ee vi DOUE CNIS Mantal ae ee erat vi Manuals EGLE ee roles ee reise vi TOC OM Dee ee ee ee ee Vil E TOAS A A la E E neta ee ee E E re EON nee E eens Vill Cautions and ALAMA ee ibid dai eee nee eee nee eee Vill CAIRN OO Seesen Vill AN AIDS ene eee eee nen ne need 1X SEC ON Tee nee l SOSPESIAAOO ASA as cad disk aa l TAA See OT Jaka A kasta E 0 l E E ET T eee ee eee 2 A ee een 2 O 2 SDSFE31xx 100 Industrial part numbe S cccccccccceeeseeeeeeeeeeeeeeeeeeeeeeeeesseeeeseeseeseseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeees 3 Standard 1 0108 57 E SAAD AUSA a 3 Physicak deschpuon E siili hc ls mail linlik eben allu t sikindlalt 4 Deviceserver parts and Iunelions eis ES sense 4 SCCO A RT A ee es RL reed 7 Installation ae Re ren 7 In TINTS SCCU OM case ES 7 Mounlins location nenne sel 8 Installation eonsideralions ze eek Bis eisen 8 InstallatiorrCaullons rennen 8 DIN tail cp and DIN Tall tm Outi Oe esas 9 Mounino the DIN Tall IN ee Reese 9 DIN rail and device server mounting CONSIASTAatiONS ooccnccnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnns 9 Mounino the device SOLVE ne Reel 10 Grounding the Device SE aos 11 MALLA con ON eee 11 DENCES AVE
5. Transition Networks SDSFE31xx 100 Industrial Device Server Intentionally Blank X 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Section SDSFE31xx 100 Industrial Device Server In this section These are the topics General description 2 SDSFE31xx 100 Industrial part numbers Physical description Transition Networks SDSFE31xx 100 Industrial Device Server General description Overview The SDSFE31xx 100 Industrial Device Server features complete Ethernet and TCP IP network support that allows devices in industry with RS 232 connectors milling machines measurement instruments and robots to connect to LAN based automation Other devices typically found on campus networks such as card readers code readers lab equipment medical equipment and other similar serial devices can now instantly migrate to a TCP IP network Additionally the Device Server enables monitoring and managing up to 4 096 serial devices from a single PC with help from the serial IP Redirector software Features The SDSFE31xx 100 Industrial Device Server has the following operational features e Fast Ethernet fiber port 100Mbps e Serial port with asynchronous data rates up to 115 2 Kbps e Relay output for power failure and link down e ST SC connectors for multimode or SC connector for single mode e Extends distance of up to 2km 1 2 miles multimode fiber and 80 km 49 7 miles long haul single mode fiber e DIP switches
6. e The virtual COM port selections and settings will be maintained When upgrading the software you will be prompted to uninstall the old version of the software as shown in Figure 51 Serial 1P x Serial 1P Version 4 3 2 12 already installed You must uninstall the existing version before installing SenalP Version 4 6 2 102 Do pon want to uninstall the existing version of Serial 1P Figure 51 Uninstall Message Box IMPORTANT Excluding Windows XP in all other Windows environments you must restart the computer to finish uninstalling the software before installing the upgrade Not restarting the computer could result in an error during the software upgrade Action Click the YES button to uninstall the software when successful the installation wizard will appear shown in Figure 52 ji Serial IP Version 4 6 2 1021c2 Setup Oe x MW WE Welcome to the Serial lP Installation Wizard It is strongly recommended that you exit all Windows programs before running this setup program Click Cancel to quit the setup program then close any programs you have running Click Next to continue the installation WARNING This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law i Cancel Figure 52 I
7. 1 800 260 1312 Continued on next page International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Installing serial IP redirector software continued 6 Click the AGREE radio button la Click the NEXT button and the destination folder will appear as shown in Figure 46 ie Serial IP Version 4 6 2 102rc2 Setup lel E Destination Folder Select a folder where the application will be installed A HS The Wise Installation Wizard will install the files for Serial IP in the following folder To install into a different folder click the Browse button and select another folder You can choose not to install the product by clicking Cancel to exit the Wise Installation Wizard Destination Folder C Program Files Tactical Software Browse Wise Installation Wizard i Cancel Figure 46 Software Destination Folder Dialog Box If the destination folder in the dialog box is not where you want the software to load click the BROWSE button and then select a new location Click the NEXT button and the select features dialog box will appear as shown in Figure 47 Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 47 Transition Networks SDSFE31xx 100 Industrial Device Server Installing serial IP redirector software continued 48 i Serial IP Version 4 6 2 102rc2 Setup Selec
8. DB 9 crossover straight thru cable e 18 serial cable pinouts onoocionocionnnconccnonononnononnononnonos 60 Device Server COnligURAt ION ee 23 configured as DTE ann 60 dip Switches see 19 TEatUL OS ae 2 A A 1 Models ae 3 modes converter CR and server DS 28 29 mounting to DIN rail 10 number of ports Managed oococcconcccnncocononannononnonannonoss 2 operating voltage range oooooncnicnoccononconcnnnnnnnnnnonos 2 7 terminal Dl ck u uu0 ee 12 terminal block plug alarm WINNE anna 15 DOWEL WIFINS ueeusecssnsensnnsensensennsnnaensensenannsanaensanaensensensens 13 wiring recommendations ererereree DIN Rail ol o E wen E EE E a 9 device server MOUNTING sesesesssesesesssesesesesesesesee 10 A sea 19 Fiber cable connection soscada 17 cable physical characteristics 6 cable specifications eeeesesssessesessesessenensenenenennnnnn 61 optic specificati ONS 61 Firmware download io 32 HTTP upgrade 32 33 34 TFTP server upgrade 34 35 A ataman ila 1 26 Firmware Version 26 Grounding device server 1 GUI hardware firmware versions 26 Mall MEN iia 24 master info submenu usesesessesessesensenensennnnnnnnnnnnnn 26 RS 232 connection status display item AESCADUON Suit 30 RS 232 transfer config display m o ooo 27 serial port config submenu
9. Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Section VI Cable Specifications Introduction This section provides copper and fiber cable specifications In this section These are the topics DB 9 RS 232 serial cable specifications 60 Fiber cable and optic specifications Transition Networks SDSFE31xx 100 Industrial Device Server Copper DB 9 RS 232 serial cable specifications What is RS 232 RS 232 is a serial device control protocol that provides an interface between Data DB 9 Terminal Equipment DTE and Data Communications Equipment DCE that employs serial binary data interchanges DB 9 cable Wire category 3 to 5 specifications Maximum data rate 100Kb s 115 2Kb s asynchronous distance dependent Gauge 24 to 22 AWG Maximum cable distance 50 ft 15 24 m DB 9 cable Figure 59 shows the DB 9 RS 232 serial cable pin assignments and pinout chart pinouts O ON OD O A ON gt No Code Description Bl irection Data Carrier Detect Receive Data Transmit Data Data Terminal Ready Ground Data Set Ready Request to Send Clear to Send Ring Indicator 1 2 3 4 5 6 T 8 9 Figure 59 DB 9 Connector and Cable Pin Assignment Chart Note The Device Server is configured as a DTE device Use a straight through cable for connecting to a DCE device or a crossover cable for connecting to other DTE devices 60 24 Hour Technical Support 1 800 260 1312 International 00
10. This will be the setting for the Input enable disable serial data arriving at the serial port in a bit stream Enable if serial data on the serial interface will be in packet mode Packet Mode Inter Packet This time value in milliseconds is the delimiter Timeout timeout value between serial packets This only applies if packet mode of the serial input is enabled The value will largely depend on the serial device connected to the Device Server or the field bus protocol used i e Modbus etc Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 29 Transition Networks SDSFE31xx 100 Industrial Device Server Configuration software continued Serial connect Click the serial connect status link to launch the Device Server serial connection status submenu status submenu See Figure 24 RS232 Connection Status Connect Status Not Connected Peer IP Address 0 0 0 0 Dest Sree Port Number 00 Byte Counts From UART E Byte Counts To Network 0 Byte Counts From Network 0 Byte Counts To UART i Clear Figure 24 RS 232 Port Connection Status Submenu Display This menu provides instant information about serial port connectivity In this submenu you can view a current connection status instance also clear the information on the screen by clicking the CLEAR button A description of each menu item is shown below Submenu Item Connect Status Peer IP Address IP of the r
11. Transfer Configuration Submenu Display Use this menu to configure server client mode and the serial port This menu shows the serial port configuration and allows configuring all fields When using a serial device with Modbus RTU protocol enable Packet mode for the serial input Also enter an appropriate inter packet timeout value to facilitate smooth data communications Click the APPLY button to save and activate the changes Click the RESET button to return to the previous settings before applying the changes The following explains the server client mode configuration submenu items Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 27 Transition Networks Configuration software continued Serial port config submenu continued Submenu Item Server Client Type TCP Port Number Connection Idle Time DS CR Modes PC LAN Port Network _Fiber j SDSFE31xx 100 Industrial Device Server Defines whether the Device Server is acting as a server or a client In Device Server Mode this setting w ll always be Server In Converter Mode this setting can be either Server or Client In Converter Mode enter the IP address of the remote device This field is NOT USED in Device Server Mode Device Server mode DS the TCP port number is the number that the Device Server uses to listen for connections also other devices must use this port to contact the Devic
12. generators such as motors Do not expose or subject the Device Server to vibration dust and direct exposure to sunlight Leave at least 5cm 1 97 in of space at the front and rear of the unit for ventilation To prevent the Device Server from sliding around affix the provided rubber pads to the bottom plate or mount the device to a DIN Rail Installation Observe the following cautions when installing the Device Server cautions A CAUTION Only qualified persons should install the Device Server Failure to observe this caution could result in poor performance or damage to the Device Server CAUTION Install the Device Server in an operating environment where the temperature range is from 0 C to 70 C 32 to 158 F with relative humidity of 5 to 90 non condensing Failure to observe this caution could result in poor Device Server performance CAUTION DO NOT install the Device Server in areas where strong electromagnetic fields EMF exist Failure to observe this caution could result in poor Device Server performance and data corruption 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks DIN rail clip and DIN rail mounting Mounting the The aluminum DIN Rail Clip should already be mounted to the back panel of the DIN rail clip Device Server If you need to attach the DIN Rail Clip position the stiff metal spring as shown in Figure 3
13. il appartiendra alors a l utilsateur de prende les measures sp cifiques appropri es Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Compliance information continued European In accordance with European Union Directive 2002 96 EC of the Regulations European Parliament and of the Council of 27 January 2003 Transition continued Networks will accept post usage returns of this product for proper disposal na The contact information for this activity can be found in the Contact Us portion of this document X CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHONE NETWORK Failure to observe this caution could result in damage to the public telephone network Der Anschluss dieses Ger tes an ein ffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verst sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformit t 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 69 Transition Networks SDSFE31xx 100 Industrial Device Server Intentionally Blank 70 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Appendix A Technical Specification
14. information Figure 15 shows the LEDs and a chart that explains the function of each 100 O O LNK ACT POSTC ACT Front View Description Power PWR Lights green when input power is good Redundant Power RPS Lights green when receiving external power from redundant input source Alarm ALM Lights red signaling an alarm when an external alarm is connected during a down link condition on any port or during primary redundant power failures LNK ACT Lights green when connected to another device Flashes amber to indicate when the fiber port receives link pulses from a compliant device fiber port only Lights to indicate when the serial port is receiving link pulses or data from a compliant device Lights amber when the Power on Self Test was successful flashes when performing the POST Lights amber to indicate when receiving data from at 100Mbps fiber port only Figure 15 LEDs and Description Chart 22 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Device Server configuration Introduction Use a web browser to configure the Device Server You can set the TCP IP configuration for the device to monitor and manage attached Serial Devices via Serial IP Redirector software Web access Once connected to a network the Device Server is accessible via a web browser To access the Device Server via a web browser do the followi
15. port The Serial IP Redirector Software adds virtual COM ports to Windows operating usage systems Similar to regular COM ports that allow PC applications to use local serial ports Serial IP COM ports allow PC applications to use the serial port on the Device Server Because Serial IP COM ports work like regular COM ports PC applications do not have to be changed to use the Device Server through the Serial IP Redirector Operating The Serial IP Redirector software runs as a kernel level device driver in the environment Windows operating system This means that Serial IP COM ports are available to PC applications at all times even if no user is logged in The Serial IP Redirector is a high performance kernel mode driver with a small footprint modest memory requirements and low overhead The Serial IP applet in the Windows control panel configures Serial IP COM ports and displays their activity Configuration The Serial IP Redirector software detects and uses the specific protocol supported by wizard the Device Server When configuring Serial IP COM port use the Serial IP Configuration Wizard to verify immediately that the Serial IP Redirector can communicate with the Device Server over the network Networked The networked pieces fit together in the following manner device server port EN ainelt network via TCP IP attached to the Device Server D Configure the Serial IP Redirector software to create virtual COM port _ provi
16. show the Device Server system backup file submenu submenu shown in Figure 34 System Backup Press Backup Setting to save configuration data to pe Backup setting Choose backup file and restore setting Browse _Restore Setting Figure 34 Configuration System Backup File Display Configuration To backup the configuration file to the local PC do the following file backup Click the BACKUP SETTING button on the display and the save config file dialog box will appear as shown in Figure 35 File Download Do you want to save this file E Name config bin Type Unknown File Type 64 1 KB From 192 168 0 254 Save Cancel While files from the Internet can be useful some files can potentially Y harm pour computer IF you do not trust the source do not sawe this file What s the risk Figure 35 Save System Backup File Dialog Box 2 Click the SAVE button to save the config file and a prompt will appear to select a location for storing the file on the local PC Select the location then click the SAVE button to save the config file Continued on next page 36 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Configuration software continued Configuration file restore To Restore the backup configuration file do the following 1 Enter the file name or click the BROWSE button to locate the
17. the following Enter the IP address the TFTP server field as shown in Figure 31 Upgrade System by TFTP IP Address 192 168 0 155 File Name TRANS 601 V122 b stant Upgrade by TFTP Figure 31 TFTP Upgrade Submenu Display Enter the file name in the file name field as shown in Figure 31 above Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Configuration software continued FW upgrade via TFTP continued Click the START UPGRADE BY TFTP button to start downloading the firmware and a system upgrade timeout display will appear as shown in Figure 32 System Upgrade Programming Do not mterrupt or power off the device while programming Please wait for seconds The System will return to index page Figure 32 System Firmware Upgrade Time Out Display When the firmware upgrade is complete the index page system information will appear as shown in Figure 33 System Information Description SenalTE Device Server Model Name K5 232 To ETH Device Server Up Time 0 day 2 hour 25 min 46 sec Figure 33 Index Page System information Display Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 35 Transition Networks SDSFE31xx 100 Industrial Device Server Configuration software continued Configuration Click the configuration file link to
18. the six contact terminal block plug for redundant power do the following plug wiring Note The six contact terminal block plug is constructed keyed to mate with the Device Server terminal block When wiring the plug for power use the polarity markings next to the terminal block on top of the Device Server to ensure proper connection Turn the external power source OFF Strip the power wires as required Insert one stripped power wire into the terminal block plug Observe polarity See Figure 7 Secure the wire using a flathead screwdriver by tightening the contact screw See Figure 7 Repeat Steps 3 and 4 until all wires are installed and secured Terminal Block Plug 3 Views Primary Power Screw Contacts Contact Screw Wire x Plug End Side View Figure 7 Six Contact Terminal Block Plug Primary Redundant Power Wiring Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 13 Transition Networks SDSFE31xx 100 Industrial Device Server Connecting power to the Device Server continued Terminal block plug wiring continued Insert the terminal block plug into the Device Server s terminal block as shown in Figure 8 Wire Harness Terminal Block Plug 100 O O LNK ACT POSTC ACT E RS 232 Front View Figure 8 Wired Terminal Block Plug Inserted Into Device Server Make sure that the DC power source is stable and clean 8 Turn ON
19. to enable disable alarm function e Seven 7 LEDs for at a glance device status e Suitable for industrial harsh environments e Wide voltage range 9 48VDC e Dual redundant DC power inputs 2 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks SDSFE31xx 100 Industrial part numbers Standard The part numbers shown in Table perform as described in this manual models Table 1 SDSFE31xx 100 Industrial Part Numbers Part Number Port 1 DB 9 Port 2 Fiber Optic 100Base FX 50 ft 2 km 1 2 miles 50 ft 2 km 1 2 miles 50 ft 20 km 12 4 miles 50 ft 40 km 24 8 miles 50 ft 80 km 49 7 miles Note The distances for ports 1 and 2 listed in Table 1 are typical maximum distances the physical characteristics of the network will affect the actual distances 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 3 Transition Networks Physical description SDSFE31xx 100 Industrial Device Server Device server Figures 1 and 2 identify the SDSFE31xx 100 Industrial Device Server parts and parts and functions functions 9 8 T 100 O O LNK ACT POSTC ACT 6 5 Front View AAN 19901 SANS Redundant Power RPS LED Alarm LED Fiber Port Link Activity Serial Port Activity RS 232 Serial Port Power ON and Self Test POST LED Fiber Port 100Mbps LED Fiber Port Primary Power LED Figure 1 SDSFE
20. uperade EAA 50 importance NOTICE eeeeneesenessensnsnsnennnennnnnnnnnnsnnnnnnnnene 50 Installation ri 46 47 48 49 network requirements oococcncccococccnnoccnnnncnannncnnnnonooos 45 Operating environment sesssesssesnsesessenennnnnsnnnn 44 pre installation steps eeesessessesesesnenennnnenennnnn 45 a lai ka aaa 45 supported platforms wreorennenenene 45 Regulations Canadian ee 68 European 68 69 FCC regutonszen een 68 Relay OW CO WIPE rasa rea Te EROE I5 Restore Restan lic 41 RS 232 o AAA ohule atakk 18 SDSFE31xx 100 Industrial Device Server cable DINOU assi lidia 60 port connection StatUS oooccccicnoniononcconononncncnnononnonos 30 SPECINICALION ico 60 transfer configuration sessesesessesssennenennennnnnnnnnnne 27 what N 60 Serial Tunnel ee Sa la 29 SNMP Communities two community strings get and set 38 Software 12111 11 40 8 14 04 A ATU 25 serial IP redirector useseesesesseseesesnesennesesnennnennnnenne 44 System OS ee eee ee 41 A 41 Technical Specifications ooocininninnononmmmmms mo 7 Terminal Block A II TU MT I5 VOUE ee ee 12 Terminal Block Plug alarm MO lo ela I5 DOWER WINNS essen 13 Troobleshootine ra 58 User Name Password how LO A II SS 31 VV AES saingi vaikust ala aaa ix NN ALLAN erinnern 67 COn 66 WhO CO CONtACE ea 66 Web Access SON SUFAA ON irina eee a 23 74 24 Hour Technical Support
21. 0 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Warranty continued How and where to send the returns Customer pays non compliant return costs Non warranty repair costs Repaired non warranty products This warranty is your only remedy 24 Hour Technical Support 1 800 260 1312 Send the defective product postage and insurance prepaid to the following address CSI Material Management Center c o Transition Networks 6103 Blue Circle Drive Minnetonka MN 55343 U S A Attn RETURNS DEPT Credit Return Authorization CRA or Return Material Authorization RMA Failure to protect the product during shipping may void this warranty The return authorization number must be written on the outside of the carton to ensure its acceptance We cannot accept delivery of any equipment sent to us without a CRA or RMA number The customer must pay the non compliant product s return transportation cost to Transition Networks for evaluation of said product s for repair or replacement Transition Networks will pay for shipping the repaired or replaced in warranty product s back to the customer any and all customs charges tariffs or and taxes are the customer s responsibility Before making any non warranty repair Transition Networks requires a 200 charge plus actual shipping costs to and from the customer If the repair is greater than 200 an estimate is issued to t
22. 1 800 260 1312 International 00 1 952 941 7600
23. 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Fiber cable and optic specifications Transition Networks Fiber cable Cable physical characteristics must meet or exceed IEEE 802 3 specifications characteristics Parameter Specification Bit Error Rate lt 10 Single mode fiber 9 um Multimode fiber 62 5 125 um Multimode fiber 100 140 85 140 50 125 um Fiber optic The following shows the fiber optic specification specifications Fiber Cable Specifications SDSFE3111 100 1300 nm multimode Fiber optic transmitter power min 19 0 dBm max 14 0 dBm Fiber optic receiver sensitivity min 31 0 dBm max 4 0 dBm Link budget 12 0dB SDSFE3113 100 1300 nm multimode Fiber optic transmitter power min 19 0 dBm max 14 0 dBm Fiber optic receiver sensitivity min 31 0 dBm max 4 0 dBm Link budget 12 0dB SDSFE3114 100 1310 nm single mode Fiber optic transmitter power min 15 0 dBm max 3 0 dBm Fiber optic receiver sensitivity min 30 0 dBm max 3 0 dBm Link budget 15 0 dB SDSFE3115 100 1310 nm single mode Fiber optic transmitter power min 15 0 dBm max 8 0 dBm Fiber optic receiver sensitivity min 34 0 dBm max 7 0 dBm Link budget 19 0 dB SDSFE3117 100 1550 nm single mode Fiber optic transmitter power min 3 0dBm max 3 0 dBm Fiber optic receiver sensitivity min 37 0 dBm max 0 0 dBm Link budget 34 0 dB 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 61 Transition Netw
24. 31xx 100 Industrial Device Server Front View Continued on next page 4 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Physical description continued Device server parts and functions continued 10 Terminal Bock 11 Grounding Screw 12 DIP Switches 13 Alarm Relay Contacts 14 Redundant Power Input 15 Primary Power Input Top View 16 DIN Rail Bracket 17 Metal Spring 18 Screws Back View Figure 2 SDSFE31xx 100 Industrial Device Server Top and Back Views 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 5 Transition Networks SDSFE31xx 100 Industrial Device Server Intentionally Blank 6 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Section II Installation In this section These are the topics Device Server mounting location 8 DIN rail clip and DIN railmounting O 9 Transition Networks SDSFE31xx 100 Industrial Device Server Device Service mounting location Installation The location selected to install the Device Server can greatly affect its performance considerations When selecting a site consider the following Install the Device Server in a fairly cool and dry place See Technical Specifications for the acceptable temperature and humidity operating ranges Install the Device Server in a location free from strong electromagnetic field
25. 60 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Grounding the Device Server Wiring considerations Device server grounding A WARNING Be sure to disconnect power before installing and wiring the Device Server Failure to observe this warning could result in an electrical shock The following wiring considerations are recommended Use separate paths to route wiring for power and device data cables If power wiring and device data cables must cross make sure that the wires are perpendicular at the intersection point Do not run signal or communications wiring and power wiring in the same wire conduit To avoid interference wires with different signal characteristics route separately Use the type of signal transmitted through a wire to determine which wires should be kept separate The rule of thumb is wiring that shares similar electrical characteristics can be bundled together Keep input and output wiring separated Label the wiring to all devices in the system for clarity A CAUTION The Device Server must be mounted to a well grounded surface Failure to observe this caution could result in EMI problems The Device Server can eliminate the effects of noise due to electromagnetic interference EMI via proper grounding Always run the ground connection from the ground screw to a grounding surface before connecting DC power See Figure 5 Terminal Block Equipment G
26. ED Device Server Work Station Figure 13 DB 9 Cable Installation 18 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks DIP Switches DIP switch The Device Server features four DIP switches on the top panel that set the responds position for the alarm in case of power loss or link failure Figure 14 shows the DIP switch descriptions and a chart that explains each setting Primary power alarm enable ON disable OFF Redundant power alarm enable ON disable OFF Fiber port alarm enable ON disable OFF N A Figure 14 Dip Switch Settings and Explanations Note DIP switch changes will not become active until the Device Server is power cycled turned OFF then ON 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 19 Transition Networks SDSFE31xx 100 Industrial Device Server Intentionally Blank 20 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Section III Operations In this section These are the topics Light Emitting Diodes LEDs Device Server configuration 24 Configuration software 2 1 Transition Networks SDSFE31xx 100 Industrial Device Server Light emitting diodes LEDs LEDs The Device Server has LED indicators located on its front panel The LEDs present at a glance network status and provide real time connectivity
27. IO nee ee el ee ee ea 11 Connecting power to ti DEVICE Sia 12 E ee ee ee 12 Termnal Bl ock ple Wan ve nee m ete 13 Connecino an alarmi TXE oaei das 15 AATE lAN A 15 Alarm relay A ee ee nen 15 Fault Adei ONS inisee a 16 LOnnee ne Golo 41672121 ee ee nee nie 17 251015 2007210 598 18851821 16248 on ei ee einen 17 Connecting DBJ Gb er riss 18 DB 9 Table CONO cons 18 DB o Cable installation ei 18 DIP SWICCH ai eier 19 DIP Switch POSTIONAESGEIPUOAS u else 19 Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Transition Networks SDSFE31xx 100 Industrial Device Server SEO A nen anne 21 PA SEED SA A asuti t Ai 21 DPA TINTS Mii adds 2 ash cata Modes LEDS zes ee 22 DENSA RER 22 DEVISE DEI VEL CORSA RE ee 23 Introduction sa nee ee alata 23 WY CACC Seesen ehe nen 23 CONTA STATI ON SOWAS ee little 25 Expanded SOMA ee DESO i alia 25 Systems details ment OPUS leere 26 System INTOLNALOH SUDIC N een di 26 Master information som a een 26 Contiouratioh mento ptos tt SUES 21 SELLAL POLE conto SUDE US daik alana madala maaala ak muslim EE a kalal 21 Se al COMMECE stas SU OMS TN a aA a aa 30 Ment confie men options ee as 31 User conie Miedo 31 Firmware dowload submit 32 EN AGS A tn een 32 EWV mponda via E IP ee een nee 34 Gonteuration Me SUDMCiUs nee eines ia 36 Contouraton ale backup A 36 GOnHotration THE TESEOLE eesse A A a aa i 37 SNMP contrat Med ad Ad a k
28. If used this includes Windows XP service pack 2 firewall What is Before installing the Serial IP Redirector software do the following needed Obtain administrator privileges before installing the software 2 Install the Device Server on the TCP IP local area network Follow the general guidance about Device Server configuration in this manual Also see the latest help files the Serial IP Redirector software by clicking the HELP button on the Serial IP Control Panel dialog box 5 Install the software on the PC that will use the serial port 1 2 3 Configure the Device Server to provide its serial port to the network 4 5 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 45 Transition Networks Installing serial IP redirector software Software installation 46 To install the software do the following SDSFE31xx 100 Industrial Device Server Login as a user with administrator privileges Quit all Windows programs using COM ports Install the Serial IP Redirector Software CD into the PC Laptop that will be in communication with the serial port of the Device Server to launch the installation wizard dialog box shown in Figure 44 Welcome to the Serial IP Installation Wizard It is strongly recommended that you exit all Windows programs before running this setup program Click Cancel to quit the setup program then close any programs you have runn
29. Industrial Device Server Transition Networks Installing serial IP redirector software continued ig Serial IP Version 4 6 2 102rc2 Setup Ready to Install the Application Click Next to begin installation gt Click the Back button to reenter the installation information or click Cancel to exit the wizard V View Release Notes when install completes Wise Installation Wizard lt Back a Cancel Figure 49 Ready to Install Application Dialog Box Action Click the view release notes check box if not selected 12 Click the NEXT button to install the software When completed the successfully installed message box will appear as shown in Figure 50 7 Serial IP Version 4 6 2 102rc2 Setup The Serial IP software has been successfully installed Click the Finish button to exit this installation a i lance Figure 50 Install Successful Message Box Click the FINISH button and the release notes will appear on the screen Close the release notes and the Serial IP Control Panel will appear 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 49 Transition Networks SDSFE31xx 100 Industrial Device Server Upgrading serial IP redirector software Software upgrades 90 If you are installing a software upgrades please note e The existing software must be the same major version version 4 e The setup program will remove the existing Serial IP software
30. NS 550s eine A ee 59 LAO CICLO ner ee nee ee 59 Ines CO ee een 59 Copper DB 9 RS 232 serial cable SpecifICatiODS oooooccconncncnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnninnss 60 AN at tod RS 2327 DB 0 An ee ee ee et 60 DB cable SOCOM aloe a 60 Deal DON iaa 60 Fiber Cable and optic spe e1l1eau on a ee ae ee Beer ee 61 Fiber cablecharieterisues ee einen een ash 61 1019159 014769 5 85104 181002 onen een 61 BS UG A een ee 63 Contact Us W aray A as o 63 COMOROS nn wee OO 63 Introduce ELO Oe a een O 63 BI SEC ALO een 63 FOR CU ee RA RR 64 Technical support sen a sa een seen Series ias 64 ENE Web Halle nase ns 64 Web Dasedidrain ne t aie en nisse Ree 64 A Scares lee sense ee 64 A a needs 64 Conformity gecl arallien a ee ee ee 65 NA end 66 LIA CAUSAS ido 66 Whatthe warranty doesnot COME dd 66 Establishing PASA ASS dd 66 NO LO GOMAGE LOLAS da 66 HOw and where 10 send ING return id di ai 67 Customer pays non compliant return cHsB aii 67 NOA MALLA TEPAEGOSES ed 67 Repaired non Warraniy Produc gos 67 MIS MALAM VAS your OV TEMG SS 67 Compliance IO oon a t riksa elie e t ee aia t a ele nom en 68 SOMATA A A N 68 COLT A ne E A 68 Canadian coma ona ta ee een 68 2483897 01921491 cOn St Sad 68 ADDEN BER Gane eee TASA MeO URE PORN E 71 Technical Speci amp Oo tn td AAA rer here 71 SDSFES31xx 100 specifications notices and warnings cccccccccceseseeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeeee
31. SDSFES31xx 100 specifications notices and warnings Parameter Description Standards IEEE 802 3 100BASE FX Fast Ethernet EIA TIA RS 232 EIA TIA 574 1x 9 pin serial connector D sub male Fiber up to 120 000 meters 74 5 miles Serial up to 15 meters 50 ft Serial 115 2 Kbps asynchronous Signals TxD RxD CTS RTS DTR DSR RI aa Safety Compliance CISPR22 EN5022 Class A EN55024 EN60950 Class A FCC Class A and CE Mark 0 to 70 C 32 to 158 F 20 to 80 C 4 to 176 F Operating Humidity 5 to 90 non condensing altitude 0 10 000 ft Continued on next page Transition Networks SDSFE31xx 100 Industrial Device Server SDSFES31xx 100 specifications notices and warnings continued Notices e The information in this user s guide is subject to change For the most up to date information on the SDSFE31XX 100 Industrial Device Server the user s guide on line at www transition com e Product is certified by the manufacturer to comply with DHHS Rule 21 CFR Subchapter J applicable at the date of manufacture e IMPORTANT Copper based media ports e g Twisted Pair TP Ethernet USB RS 232 RS422 RS485 DS1 DS3 Video Coax etc are intended to be connected to intra building inside plant link segments that are not subject to lightening transients or power faults Copper based media ports e g Twisted Pair TP Ethernet USB RS 232 RS 422 RS 485 DS1 DS3 Video Coax etc are NOT to be conn
32. W upgrade via HTTP continued 2 Click the OPEN button on the choose file dialog box to populate the file name field with the firmware upgrade address as shown in Figure 28 Upgrade System by HTTP File Name HATRANS_601_122 b Start Upgrade by HTTP Figure 28 HTTP Firmware File Name Captured Click the START UPGRADE BY HTTP button to start downloading the firmware and a system upgrade timeout display will appear as shown in Figure 29 System Upgrade Programming Do not mterrupt or power off the device while programming Please wait for seconds The System will return to mdex page Figure 29 System Firmware Upgrade Time Out Display Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 33 Transition Networks SDSFE31xx 100 Industrial Device Server Configuration software continued FW upgrade via HTTP continued FW upgrade via TFTP 34 When the firmware upgrade is complete the index page system information will appear as shown in Figure 30 System Information Description senal TP Device Server Model Name ES 232 To ETH Device Server Up Time 0 day 2 hour 25 min 48 sec Figure 30 Index Page System information Display Click the serial port config link to modify the configuration based on the new firmware Note The firmware file must be stored on the TFTP server before upgrading by this method can occur To upgrade the via TFTP server do
33. ae 38 SNMP communities sumen dis 38 o oo nee A 39 Sym restore SUMEN ee ae ea 41 A e eco EE E E ASE ENGE Tee 4 Ss A A COIE mt mm aac E esse 4 SP a M a E E E E E 43 SeralIp Red rector SO LWW A esasa a a Sac a a a a a T ndal kad 43 A a a ee 43 Serial IP redirect software desenplohses seen en 44 COMPOT AC ee ee a 44 Operatie EA VALOAPAEME dd 44 CORP UL ON VII Innereien 44 ING OW OKSA device seven ee eier 44 Getting started and software pre installations considerations ooooococccnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnonnnonnnnnonenenoss 45 Pre mstallation considetalions naeh Aaa teeta u 45 W hatis needed en ts 45 Installing serial IP redirector software ui ee I BE ea 46 S LM ALE INS Al al OB see es 46 Uperadine serial IP redirector software ae tava katla khaan ad 50 SI A Seele een ust kalal 1 laka 50 Creatine virtual COM POr E 51 COMO Pa idas 51 Virtual COM Port creation er ee 52 COM Port COn 52 JE LS MATATA Tal A A A id 55 JE EG MZA 15 SUCCESS ee A a a 55 Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks SG CMO Nahid ee see a alla a a aaa E li 57 TrOUDIESHOO Nt ri daa ai ee maa a aaa eae a al 57 A 57 IO eee satan ee ee ee ER EAT Eee 3 7 Troubleshooting problem and corrective action table ooocccccncnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnss 58 SOHN asc EM AS ee ee es 59 Cable SPCCIMCAMO
34. d understand all content identified by these two symbols warnings Di A Cautions and warnings appear here and throughout this manual where appropriate Failure to read and understand the information identified by the caution and warning symbols could result in poor equipment performance damage to equipment or injury to persons Cautions Cautions indicate the possibility of damage to equipment A CAUTION Make sure that the Device Server is mounted with proper space around it for ventilation heat dissipation Failure to observe this caution could result in damage to the Device Server A CAUTION Please exercise caution when using power tools Do not install this unit in damp or wet locations or in close proximity to very hot surfaces Failure to observe this caution could result in damage to the Device Server and cables A CAUTION Only qualified persons should install the Device Server Failure to observe this caution could result in poor performance or damage to the Device Server A CAUTION Install the Device Server in an environment where the temperature range is from 0 C to 70 C 32 to 158 F with relative humidity of 5 to 90 non condensing Failure to observe this caution could result in poor Device Server performance A CAUTION DO NOT install the Device Server in areas where strong electromagnetic fields EMF exist Failure to observe this caution could result in poor Device Server performance and da
35. des access to 1ts serial port instead of the local COM port instead of local serial ports 44 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Getting started and software pre installations considerations Pre installation Supported platforms considerations Intel compatible PCs with 32 bit Pentium class processor e Atleast 4 megabytes free space on the boot drive e Windows XP spl or sp2 Server 2003 2000 NT 4 0 sp6 98 95 Me Microsoft NT 2000 2003 Terminal Server Citrix MetaFrame Access Suite e VMware Software requirements e Windows Installer 2 0 or later This software is included in Windows XP and later and is available for NT 4 0 2000 and 95 from the Microsoft Download Center It is also available for Windows 98 n Internet Explorer 5 5 e Internet Explorer 4 0 or later version 5 5 or later for Windows 98 e For Windows 95 Microsoft Windows Socket 2 update Network requirements e A TCP IP network connection from the local computer to the serial Device Server e The throughput and performance of the network connection must exceed the requirements of the application in total An Ethernet local area network will easily meet this requirement e If firewalls are in the network path to the serial Device Server they must allow TCP connections to the server on the TCP port number s on which the server provides its devices
36. e Server Converter mode both converters use the TCP port number to communicate with the host This setting only applies to Converter Mode The time value in seconds is the maximum time that the TCP port will remain open with no activity Once the time value is reached the Device server closes the port to prevent the port from remaining open indefinitely This field is NOT USED in Device Server mode Device server DS mode also know as TCP IP mode is used to connect a serial device to a host via an Ethernet network This mode allows using an existing COM port based software platform across an existing Ethernet LAN See Figure 22 Serial Device Server POS w Scanner Figure 22 Serial Device Connection to a Host via Ethernet Network 28 24 Hour Technical Support 1 800 260 1312 Continued on next page International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Configuration software continued Serial port config submenu continued Submenu Tem DS CR Modes continued Converter Mode CR is used for serial tunneling across an Ethernet network between two serial ports to simulate a direct serial connection between the devices See Figure 23 Jr Fiber Fiber N Network mei Serial N ai a Z LE UL JF Device Server Device Server POS w Scanner PC LAN Port Figure 23 Serial Tunneling Packet Mode of Serial Default is disabled
37. e down the new user name and password and keep the information in a safe place This information will be required in the future to access the management portion of the software Also use this same user name and password if established here in the Redirector software to communicate with the Device Server Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 31 Transition Networks SDSFE31xx 100 Industrial Device Server Contiguration software continued Firmware Click the firmware download link to launch the Device Server firmware download download submenu You can upgrade the firmware FW via HTTP or TFTP See Figure 26 submenu Upgrade System by HTTP Fle Name _ start Upgrade by HTTP Upgrade System by TFTP IP Address Ber 1 E File Name E Figure 26 Firmware Upgrade Submenu FW upgrade To upgrade the firmware via HTTP do the following via HTTP Click the BROWSE button to locate the firmware as shown in Figure 27 Choose file Look in UDISK 2 0 H E TRANS_601_Y122 bin My Recent Documents A E Desktop My Documents ad My Network File name Places Files of type El Files Cancel Figure 27 Choose File Dialog Box Continued on next page 32 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Configuration software continued F
38. ected to inter building outside plant link segments that are subject to lightening transients or power faults Failure to observe this caution could result in damage to equipment Warnings 5 A WARNING Visible and invisible laser radiation when open Do not stare into the beam or view the beam directly with optical instruments Failure to observe this warning could result in an eye injury or blindness A WARNING Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure 72 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Index Alarm Tauleindieations nr 16 Cabling DB 9 cable types unaa a a a 18 DB 9 to Serial Porta anne 18 A ee Bes 17 Caution amp Warnings deN ONS oraiiio taa cele ected viii COM Port and e 52 configuration usessesssesssesessesesnenennenenn 52 53 54 55 configuration wizard uesessesessesessesesenensennnnennnnnnnnn 55 control Dane ae 5 creating vita la 52 if the wazard fails configuring eeeee 55 A es 56 number Ol sn ee 52 SEE FEIN en anne 52 ISIS O 44 Configuration COM port Ward a 55 expanded software tree wrrworeoeee 25 ROW tO Backup rara ea 36 37 IPaddress ie 35 IPtrapesa sen eek 39 SNMP communities eesesesessnesnesesnenennenennenennenennen 38 system backup are 36 O nai lina 23 Connection ASTME a mada 28 A pE O E T 30 Contact Vasen 64
39. eeeeeeeeeeeeees 71 NP EEEE EE ee ee E 2 al koe N een 12 NNO os cc a ae EEE SEE ee 73 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 lil Transition Networks SDSFE31xx 100 Industrial Device Server Intentionally Blank iv 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Trademark copyright and product classification information Trademark All trademarks and registered trademarks are the property of their respective owners Copyright 2006 Transition Networks All rights reserved No part of this work may be restrictions reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A FCC warning Fe This equipment has been tested and found to comply with the limits for class A devices pursuant to part 15 of FCC rules These limits are designed to provide reasonable protection against harmful interference in a commercial installation This equipment generates uses and radiates radio frequency energy therefore if t is not installed and used in accordance with the instructions in this document could cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference the user will be required to correct the interference at the user s own expe
40. eft side of the GUI screen under the Transition logo are five menu items software tree e System Details e Configuration e Mgmt Config e SNMP e System Restart Figure 18 shows the expanded software tree an explanation of each menu option starts on the following page N Main Menu Da System Details Master Info System Info Configuration Serial Port Confi Configuration File SNMP Confi E SNMP Communities IP Trap Manager System Restart Menu E Restart Options Figure 18 Expanded Configuration Software Tree 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Continued on next page 25 Transition Networks SDSFE31xx 100 Industrial Device Server Configuration software continued Systems details Click the Systems Details link to show its two submenu options menu options 4 System Info e Master Info System Click the system info link to show the Device Server system information submenu information See Figure 19 submenu System Information Description gt enal TP Device Server Model Name ES 2432 To ETH Device Server Up Time Odar 2 hour 25 min 48 sec ace Subnet Mask 255 255 182 168 ob Mil LIE Gateway 1192 Figure 19 System Info Submenu This menu option provides a description of the Device Server model name along with the up times day hour minute second It also allows editing the IP address subnet mas
41. emote PC that is accessing the device attached to the Device Server s serial port Dest Srce Port Number Shows the destination and source port numbers source port number will be as configured Byte Counts From UART Displays the number of bytes transmitted from the serial device Byte Counts to Network Displays the number of bytes received on the TCP IP network Byte Counts From Network Displays the number of bytes transmitted from the TCP IP network Byte Counts to UART Displays the number of bytes received by the serial device Continued on next page 30 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Configuration software continued Memt config menu options User config submenu Click the Mgmt config link to show its four submenu options e User Config e Firmware Download e Configuration File e SNMP Config Click the user config link to launch the Device Server user configuration submenu See Figure 25 User Configuration User Name User Password admin Figure 25 User Configuration Submenu This option allows you to establish a username and password for Device Server management To change the user name and password do the following Type the new user name in the user name field Type the password in the password field Click the APPLY button to set the user name and password IMPORTANT Writ
42. er their community names and disable or enable their alarm function accordingly SNMP community names Alarm function disabled or enabled Continued on next page International 00 1 952 941 7600 39 Transition Networks SDSFE31xx 100 Industrial Device Server Configuration software continued IP trap manager submenu continued You can configure up to five management stations to receive authentication failure messages or other trap messages from the Device Server To assign the IP Traps do the following Click the IP address parameter field See Figure 41 Type or paste the IP address in the field Click the community name parameter field See Figure 41 Type a name in the field Select status enabled or disabled 6 Click the SAVE button to save and establish the trap Note IP Click the RESET button to reestablish the original parameter s before saving changes IP Trap Manager Address Community Name Status 192 168 0 59 public Enabled 192 168 1 11 private 0 0 0 0 0 0 0 0 0 0 0 0 Figure 41 Sample Configured IP Trap Manager Display 40 public Disable Save Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Configuration software continued System restore submenu System restore System reset Click the System Restart link to sh
43. ferable This warranty does not cover damage from accident acts of God neglect contamination misuse or abnormal conditions of operation or handling including over voltage failures caused by use outside the product s specified rating or normal wear and tear of mechanical components If the user is unsure of the proper means of installing or using the equipment contact Transition Networks free technical support services To establish original ownership and provide date of purchase please complete and return the registration card accompanying the product or register the product on line on our product registration page Transition Networks will at its option e Repair the defective product to functional specification at no charge e Replace the product with an equivalent functional product e Refund the purchase price of a defective product To return a defective product for warranty coverage contact Transition Networks technical support department for a return authorization number RAN Transition s technical support department can be reached through any of the following means Technical Support is available 24 hours a day e Tel 800 260 1312 x 200 or 952 941 7600 x 200 e Fax 952 941 2322 e Email techsupport transition com e Live web chat Transition Now e Voicemail 800 260 1312 x 579 or 952 941 7600 x 579 e All messages will be answered within one hour Continued on next page 24 Hour Technical Support 1 800 26
44. file See Figure 36 Choose backup file and restore setting Restore Seting Figure 36 Backup File Restore Display system Backup Restore Programming Do not mterrupt or power off the device while programming Please wait for seconds The System will return to mdex page Figure 37 System Backup Restore Timeout Display When the backup file is restored the index page system information will appear on the display as shown n Figure 38 System Information Description ca TP Device Server Model Name ES 232 To ETH Device Server Up Time Odar hour 0 mn 4 sec Figure 38 Index Page System Information Display Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 37 Transition Networks SDSFE31xx 100 Industrial Device Server Configuration software continued SNMP Click the SNMP config link to show its two submenus configuration e SNMP Communities menu e IP Trap Manager SNMP Click the SNMP Communities link to launch the SNMP Communities submenu communities option See Figure 39 submenu SNMP Communities Community Name GET public SET private Figure 39 SNMP Communities Display Use an external SNMP based application to configure and manage the Device Server This management method requires the SNMP agent on the Device Server and on the SNMP network management station NMS to use the same community string This management method uses two community str
45. h optical instruments Failure to observe this warning could result in an eye injury or blindness e Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 17 Transition Networks SDSFE31xx 100 Industrial Device Server Connecting DB 9 cable DB 9 cable Depending on the equipment type data terminal equipment DTE or data configuration communication equipment DCE use a null modem crossover or straight through cable See Figure 13 Straight Through Cable Crossover Cable For DCE Device Connection For DTE Device Connection Twisted Pair 1 Twisted Pairt wisted Pair 2 2 wisted Pair 2 2 3 3 3 3 Twisted Pair 2 6 6 Twisted Pair 2 6 6 Figure 12 Straight Through and Crossover Cables Note The Device Server is configured as a DTE Device See Cable Specification Section for DB 9 cable pinouts DB 9 cable To connect the DB 9 RS 232 cable to the Device Server and other equipment do installation the following Action Insert one end of the RS 232 cable into the Device Server Tighten the screws to secure the cable Repeat Steps 1 and 2 for the other equipment See Figure 12 4 Test the connection by sending a link pulse to the Device Server and the ACT LED will flash indicating a good connection DB 9 RS232 Cable ACT L
46. he customer for authorization of repair If no authorization is obtained or the product is deemed not repairable Transition Networks will retain the 200 service charge and return the product to the customer not repaired Non warranted products repaired by Transition Networks for a fee will carry a 180 day limited warranty All warranty claims are subject to the restrictions and conventions set forth by this document Transition Networks reserves the right to charge for all testing and shipping incurred if after testing a return is classified as No Problem Found This warranty is your only remedy No other warranties such as fitness for a particular purpose are expressed or implied Transition Networks is not liable for any special indirect incidental or consequential damages or losses including loss of data arising from any cause or theory Authorized resellers are not authorized to extend any different warranty on transition networks behalf International 00 1 952 941 7600 67 Transition Networks SDSFE31xx 100 Industrial Device Server Compliance information Compliances FCC Regulations Canadian Regulations European Regulations 68 CISPR22 EN5022 Class A EN55024 EN60950 Class A FCC Class A CE Mark This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against har
47. ht indicating a fault An alarm will occur under the following conditions e Any link failure cable disconnected device break down e PWR RPS power failure o Power wires are disconnected power source malfunction O Input power is out of this range 9 48V 16 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Connecting fiber cables Fiber cable When connecting fiber cables to the 100BASE FX port on the Device Server make installation sure the correct type is used ST or SC To install the fiber cables do the following Remove and keep the rubber fiber port protector cover shown below Note When not connected to a fiber cable insert the rubber protective cover into optic port to protect the optics 2 Check that the fiber terminators are clean If necessary clean the fiber connectors using locally accepted cleaning procedures Note Dirty fiber connectors on fiber optic cables will impair light transmission quality through the cable and lead to degraded performance on the port Connect the fiber cable as shown in Figure 11 RX ED TX Device Device Figure 11 Fiber Cable Connections 4 Check the corresponding fiber port LED on the Device Server to verify the connection Link Act LED should be lit rN Warning e Visible and invisible laser radiation when open DO NOT stare into the beam or directly view the beam wit
48. ing Click Next to continue the installation WARNING This program is protected by copyright law and international treaties Unauthorized reproduction or distribution of this program or any portion of it may result in severe civil and criminal penalties and will be prosecuted to the maximum extent possible under law If the install wizard dialog box does not appear at the command line type Serial IP Redrector432 exe and then press the ENTER key Press the NEXT button and a license agreement dialog box will appear as shown in Figure 45 i Serial IP Version 4 6 2 102rc2 Setup License Agreement You must agree with the license agreement below to proceed A TAS Tactical Software End User License Agreement THIS END USER LICENSE AGREEMENT this Agreement IS A BINDING AGREEMENT BETWEEN TACTICAL SOFTWARE LLC Tactical AND THE INDIVIDUAL COMPANY ORGANIZATION OR OTHER ENTITY Licensee ACQUIRING THE LICENSE TO USE THE SOFTWARE PRODUCT AS DEFINED IN SECTION 1 PURSUANT TO THIS AGREEMENT IN THE EVENT LICENSEE IS AN ENTITY LICENSEE AND THE INDIVIDUAL REVIEWING AND ACCEPTING THE TERMS OF THIS AGREEMENT ON BEHALF OF LICENSEE EACH REPRESENT AND WARRANT THAT SUCH INDIVIDUAL IS AUTHORIZED TO ACT ON BEHALF OF LICENSEE TO REVIEVY AND x do not accept the license agreement Reset lt Back Cancel Wise Installation Wizard Figure 43 Agreement Dialog Box 24 Hour Technical Support
49. ings get community string and set community string e Ifthe SNMP NMS knows the Set community string it can read and write to the MIBs e Ifit only knows the Get community string it can only read MIBs The default get and Set community strings for the Device Server are public and private respectively When new parameters are assigned click the SAVE button to implement the new settings Click the RESET button to restore the original parameters if the changes have not been saved Continued on next page 38 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Configuration software continued Transition Networks IP trap Click the IP Trap Manager link to launch the IP Trap manager submenu option manager shown in Figure 40 submenu IP Trap Manager IP Address Community Name Status 0 0 0 0 public Disable v 0 0 0 0 public Disable u 0 0 0 0 public Disable Y 0 0 0 0 public Disable 0 0 0 0 public Disable v Figure 40 IP Trap Manager Option display Table 2 describes the fields on the IP Trap Manager display Table 2 IP Trap Parameters and Descriptions Parameter Description IP Address 24 Hour Technical Support 1 800 260 1312 Enter the IP address s of the terminal s that you want to monitor for failures When a failure occurs an alarm will be sent if enabled Ent
50. is section These are the topics Troubleshooting problem and corrective action table Transition Networks SDSFE31xx 100 Industrial Device Server Troubleshooting problem and corrective action table Potential Cause Potential Solution Device Server does not e Is the wired terminal block plug power up inserted into the Device Server e Is the power LED hit No activity at the DB 9 e Is the power LED lit ort A A P e Can the Device Server receive link pulses e Is the DB 9 cable properly installed at both ends e Is the DB 9 cable good No activity on the fiber e Is the LNK ACT LED lit port green Wire and insert the terminal block plug into the Device Server s terminal block Check that DC power is at the recommended levels Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 Check the power is turned ON Send link pass from the connected device if a computer press any key and the Device Server s ACT LED will flicker each time you press the key Verify that the cable at both ends is installed properly Check pin assignments Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 Ensure that the fiber optic cable 1s installed properly into the Device Server and the compliant device Power up the compliant connected device Contact Technical Support US Canada 1 800 260 1312 International 00 1 952 941 7600 58 24
51. izard s interaction with the server The wizard typically takes 5 to 15 seconds to complete its task Continued on next page 54 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Creating virtual COM ports continued If the wizard The wizard indicates errors in the status panel with error details appearing in the log fails panel In the case of an error do the following before re running the wizard ei Review error messages in the status panel See Figure 57 Correct the ag settings Restart the wizard with the corrected settings If the wizard is The wizard indicates a successful run by messages in the status panel also the USE successful SETTING button will be active See Figure 57 2 Configuration Wizard COM IP Address of Server Port Number i 92 168 0 254 1 234 Username Password todd ing S Test for presence of a modem connected to the server Status VY Connected to Server v COM Port Control Support Detected V Server Signature Serial IP Device Server V Session Complete Log Recommendations Protocol Telnet COM Port Options DTR Emulation disabled COM Port Options DTR Emulation disabled COM Port Options DTR Emulation disabled COM Port Options DTR Emulation disabled Security Disabled 2 Stop Use Setting gt copy Canel 7 Figure 57 COM Port Configuration Wizard Contin
52. k and gateway Click the APPLY button to implement any changes Click the RESET button to restore the original settings before applying any changes Master Click the master info link to launch the Device Server master information read information only submenu See Figure 20 submenu Master Information Hardware Version 00601 0101 Firmware Version 1 02 02 built at Jun 2 2006 10 22 10 Figure 20 Master Information Read Only Submenu This read only menu displays the hardware and firmware versions Continued on next page 26 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Configuration software continued Configuration Click the Configuration link to show its two submenu options menu options e Serial Port Config e Serial Connect Status Serial port Click the serial port config link to launch the Device Server serial port config submenu configuration submenu See Figure 21 R5232 Transfer Configuration Server Chent Mode Configuration server Chent Type SERVER Remoto IP TCP Port Number l value 1024 65535 Connection Idle Time sec gt ralue 30 36001 DS CR Mode Device Server Packet mode of serial input Disable Packet mode mter packet timeout 20 mS Gralue 1 5000 serial Port Configuration Operation Mode KS232 Mode Baud Rate Parity Word Length stop Bits Flow Control Figure 21 Serial Port
53. mful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s Own expense This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le Reglement sur le brouillage radio lectrique dict par le ministere des Communications du Canada A CUATION This is a Class A product In a domestic environment this product could cause radio interference in which case the user may be required to take adequate corrective measures Achtung Dieses ist ein Ger t der Funkst rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkst rungen auftreten In diesem F ll ist der Benutzer f r Gegenma nahmen verantwortlich Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de cr er des interf rences radio lectriques
54. national 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Conformity declaration un TRANSITION Name of Mfg Model Part Numbers Regulations Transition Networks Declaration of Conformity Transitions Networks 6427 City West Parkway Minneapolis MN 55344 U S A SDSFE31xx 100 Industrial Device Server SDSFE3111 100 SDSFE3 113 100 SDSFE3 114 100 SDSFE3115 100 SDSFE3117 100 EMC Directive 89 336 EEC Purpose To declare that the SDSFE31xx 100 Industrial Device Servers to which this declaration refers is in conformance with the following standards CISPR22 1993 EN55022 1994 A1 1995 A2 1997 Class A FCC Part 15 Subpart B UL1950 21 CFR Subpart J I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s at Ameen O AP September 2006 Steven Anderson Vice President of Engineering Date 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 65 Transition Networks SDSFE31xx 100 Industrial Device Server Warranty Limited lifetime warranty What the warranty does not cover Establishing original ownership Who to contact for returns 66 Effective for products shipped May 1 1999 and After Every Transition Networks labeled product purchased after May 1 1999 will be free from defects in material and workmanship for its lifetime This warranty covers the original user only and is not trans
55. ng l Type the default IP 192 168 0 254 address if connecting with the default IP at web browser to launch the login dialog box See Figure 16 Connect to 192 168 0 254 Web Manager Remember my password Figure 16 Login Dialog Box Note The default user name is admin no password has been assigned However you can change the user name and password within the GUI via submenu item User Config Enter default user name admin as shown in Figure 16 Click the OK button to launch the Device Server s graphical user interface GUI main menu screen shown in Figure 17 Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 23 Transition Networks Device Server configuration continued Web access continued en res RS 232 To ETH Device Server lt Main Menu E System Details HC Configuration HC Mgmt Config 07 System Restart Menu SDSFE31xx 100 Industrial Device Server 100 LNK ACT AC POST System Information Description Serial TP Device Server Model Name RS 232 To ETH Device Server Up Time 0 day 1 hour 38 min 36 sec IP Address 192 Subnet Mask 255 Gateway 192 a Figure 17 Main Menu Screen 24 1254 255 o i 1 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Configuration software Transition Networks Expanded On the l
56. ng up the select ports dialog box shown in Figure 54 Select Portz Please select virtual COM ports COMTE COMe29 COM4 2 COMT 12030 G0kl43 COMAS COMS1 COM44 120413 L COMs2 COM4S COM2O COMS3 COM4E COMe1 L COMs4 COM4 COMe22 LJCOMS5 L COM4s COM2S COMS6 COM4S COMe24 COM COM5D L COMe2S LOSE 120451 LOMzE COMS3 LOMS2 OCM COM 40 COMSs LOMZS ICOM COMS4 Or enter port range below COM Cancel Help Figure 54 Select Ports Dialog Box Note You can select up to 4 096 virtual COM ports COMI and COM2 are normally physical ports so they will not appear in the dialog box Select a virtual COM port from the list COM7 in this example The COM port selection will appear in the lower panel of the select port dialog box Click the OK button to establish COM port 7 Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Creating virtual COM ports continued 4 On the Serial IP Control Panel enter the IP address and port number of the Device Server See Figure 55 Check user credentials and select use credentials below from the pulldown menu See Figure 55 Note Ifauser name and password were set when setting up the Device Server use that same user name and password here Enter a user name
57. note the side headings These side headings make it easier to find specific information The manual sections are as follows Description Device Server general and physical descriptions and features Installation describes mounting and wiring the Device Server for operation Operation LED functionality and configuration software IV How to instruction on Serial IP Redirector Software installation software upgrades and creating virtual COM ports Troubleshooting in a table format show problem causes and potential solutions Cable Specifications presents RS 232 serial cable and fiber cable specifications I Tells how to contact Transition Networks product warranty and product conformity information Presents product specifications notices and warnings Provides navigation information to specific content in this manual Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks About this product and manual continued Box contents The box should include the following e One RS 232 to 100Base FX Industrial Device Server e DIN Rail Kit e Fiber protective port caps e User manual CD e Serial IP Redirector software CD 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 vil Transition Networks SDSFE31xx 100 Industrial Device Server Cautions and warnings Cautions and Make sure that you read an
58. nse CE Mark C CE Marking European Conformity This is a Class A product In a domestic environment this product could cause radio interference as a result the user may be required to take adequate preventative measures 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 V Transition Networks SDSFE31xx 100 Industrial Device Server About this product and manual Device server Term usage About this manual Manual structure Vi The SDSFE31XX 100 Industrial Device Server design provides a DB 9 RS 232 connection over fiber cables where the connecting device has an RS 232 interface The Device Server enables serial devices such as CNCs computer numerical controls and PLCs programmable logic controllers to connect instantly to an existing Fast Ethernet network The Serial to Ethernet Device Server represents a robust solution for device controllers used by MIS personnel In this manual the term Device Server first letter upper case refers to the SDSFE31xx 100 Industrial RS 232 to 100Base FX Industrial Device Server device server first letter lower case refers to other device servers This manual provides instructions on how to install configure and operate the SDSFE31xx 100 Industrial RS 232 to 100Base FX Industrial Device Server This manual has a beginning table of contents also at the beginning of each section there is a table of contents As you traverse the manual
59. nstallation Wizard 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Creating virtual COM ports Control panel After loading the software the Serial IP Control Panel dialog box will appear as shown in Figure 53 Sertal 1P Control Panel EE E E ES Figure 53 Serial IP Control Panel Dialog Box Use the control panel to configure virtual COM ports and advanced options Note Ifthe Serial IP Redirector has been installed with the Administrator Only Mode feature the Serial IP control panel will be available only to users with Administrator privileges Changed settings do not affect the operation of currently active virtual COM ports Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 51 Transition Networks SDSFE31xx 100 Industrial Device Server Creating virtual COM ports continued Virtual COM port creation COM Port configuration 92 Alternatively you can edit the COM port ranges directly Use individual COM port numbers such as 4 5 7 and or ranges of numbers such as 11 18 30 53 separated by commas As you edit the COM port ranges checkboxes in the upper panel will change accordingly Invalid numbers or ranges will be displayed To configure virtual COM ports do the following 1 On the control panel click the SELECT PORTS button to bri
60. orks SDSFE31xx 100 Industrial Device Server Intentionally Blank 62 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Section VII Contact Us Warranty amp Conformity Information Introduction This section explains how to contact Transition Networks via Phone fax email and direct mail It also explains e What the warranty covers e Who to contact to return product e How and where to return the product In this section These are the topics Contact us Conformity declaration u Wu Warranty 6 Compliance information 68 Transition Networks Contact us Technical support Live Web chat Web based training E Mail Address 64 SDSFE31xx 100 Industrial Device Server Technical Support is available 24 hours a day United States 1 800 260 1312 International 00 1 952 941 7600 Chat live via the Web with a Transition Networks Technical Support Specialist Log onto www transition com and click the Transition Now link Transition Networks provides 12 16 seminars per month via live web based training Log onto www transition com and click the Learning Center link Ask a question anytime by sending an e mail message to our technical support staff techsupport transition com Transition Networks 6475 City West Parkway Minneapolis MN 55344 U S A Telephone 952 941 7600 Toll free U S A amp Canada 800 526 9267 Fax 952 941 2322 24 Hour Technical Support 1 800 260 1312 Inter
61. ow the Restart submenu options e System Restore e Reset Note You can restore or reset the Device Server remotely via software Click the RESTORE button shown in Figure 42 to set the Device Server back to factory defaults After the timeout display disappears all saved configuration data will be erased system Restore Factory Default Settings Restore the factory default settings of the Device Figure 42 System Restore Button Click the RESET button shown in Figure 43 to reset the Device Server After the timeout disappears the system will be reset but all configuration data will be maintained IP address etc System Reset Press Reset if the device is abnormally functionme Figure 43 System Reset Button Note System Reset has the same functionality as power cycling the Device Server 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 41 Transition Networks SDSFE31xx 100 Industrial Device Server Intentionally Blank 42 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Section IV Serial IP Redirector Software In the section This are the topics Serial IP redirector software description Getting started and software pre installation considerations Installing IP redirector software Upgrading the software Creating virtual COM ports Transition Networks SDSFE31xx 100 Industrial Device Server Serial IP redirect software description COM
62. rounded This End to Ground Top View Figure 5 Device Server Grounding Screw 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 11 Transition Networks SDSFE31xx 100 Industrial Device Server Connecting power to the Device Server Redundant Dual redundant power inputs can be connected simultaneously to live DC power power sources See Figure 6 If one power source fails the other live source acts as a backup and automatically supplies the Device Server with power Terminal Block Equipment Grounded Primary Power Redundant Power To Ground Top View Figure 6 Redundant Power Connections IMPORTANT e Power is supplied through an external DC power source Check the Technical Specification section for information about the DC power input voltage e The Device Server does not include a power switch therefore plugging a wired and active terminal block plug into its terminal block will immediately power UP the unit Continued on next page 12 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Connecting power to the Device Server continued A CAUTION When connecting DC power wires to the terminal block plug pay close attention to the polarity markings shown near the terminal block of the Device Server Failure to observe this caution could result in damage to the device Terminal block To wire
63. t Features Please select which features you would like to install CO M Port Redirector Feature Description X v Administrator Only Mode Installs the Serial IP software This feature will be installed on the local hard drive This feature requires 2050KB on your hard drive It has O of 1 subfeatures selected The subfeatures require 1369KB on your hard drive Wise Installation Wizard Disk Cost Reset Cancel Figure 47 Select Features Dialog Box On the select features dialog box you can select how much of the software you want to load on the PC Laptop disk space consideration via the pulldown menu See Figure 48 eee M COM Part Redirector ee Teen Administrator Only Mode Install the Serial 1P softy 3 Will be installed on local hard drive Entire feature will be installed on local hard drive xXx Entire feature will be unavailable Figure 48 Pulldown Menu Options Note The administrator only option restricts use of the Serial IP Control Panel to users with administrator privileges If you select this option non administrator users can use the Serial IP Redirector but they cannot open the Serial IP Control Panel 10 Click the NEXT button on the select features dialog box to launch the ready to install software dialog box shown in Figure 49 Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100
64. ta corruption A CAUTION The Device Server must be mounted to a well grounded surface Failure to observe this caution could result in EMI problems Continued on next page viii 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Cautions and warnings continued A CAUTION When connecting DC power wires to the terminal block plug pay close attention to the polarity markings shown near the terminal block of the Device Server Failure to observe this caution could result in damage to the equipment A CAUTION This is a Class A product In a domestic environment this product could cause radio interference in which case the user may be required to take adequate corrective measures Warnings Warnings indicate the possibility of injury to persons A WARNING Be sure to disconnect power before installing and wiring the Device Server Failure to observe this warning could result in an electrical shock A WARNING Fiber optics Visible and invisible laser radiation when open DO NOT stare into the beam or directly view the beam with optical instruments Failure to observe this warning could result in an eye injury or blindness A WARNING Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 ix
65. the power source and the PWR LED s should turn ON 14 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 SDSFE31xx 100 Industrial Device Server Transition Networks Connecting an alarm fixture Alarm relay The Device Server has contacts for connecting an external alarm fixture Located on the green terminal block on the top panel the relay has normally open contacts that can be wired to form a circuit for triggering an external alarm when a fault occurs light or audible alarm See Figure 9 Terminal Block Alarm Relay Top View Figure 9 Alarm Relay Contacts Alarm relay To wire an alarm to the relay contacts do the following wiring Action Verify that the external power source is turned OFF Strip the wires as required Wire the alarm as shown in Figure 10 Terminal Block Plug 3 Views Alarm Screw Screw Contacts Contacts View View Contact Screw coe Bag Wire Ports View Plug End Side View Alarm Wires Figure 10 Alarm Relay Wiring Continued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 15 Transition Networks SDSFE31xx 100 Industrial Device Server Connecting an alarm fixture continued Fault Wire the relay contacts to any warning light or audible alarm in the factory or control indications room Then when a fault occurs the relay contacts close sending a signal to activate an external alarm or turn ON a lig
66. ued on next page 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 55 Transition Networks SDSFE31xx 100 Industrial Device Server Creating virtual COM ports continued If the wizard is successful continued 96 Click the USER SETTING button on the wizard to return to the control panel Once the link 1s established you can manage the device attached to the Device Server using the Serial IP Redirector software installed on a remote computer Click the PORT MONITOR button on the control panel to bring up the port monitor shown in Figure 58 Senal lP Port Monitor File Edit Trace Options Help X Activity Trace Pot TDRDTRORCD Status IP Address com GO Connected 192 168 0 254 Figure 58 Serial IP Port Monitor Note If more devices are attached and connected the status and IP address of those devices will appear against each Virtual COM port listed 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Section V Troubleshooting Introduction This section provides basic troubleshooting information for the Device Server via a problem and corrective action table The problems are stated in the problem column and the action s to take for the problem is stated in the corrective action column If the corrective measures listed do not correct the problem contact our 24 Hour Technical Support department at 1 800 260 1312 International 00 1 952 941 7600 In th