Home

Transition Networks CSEFE10XX-10X User's Manual

image

Contents

1. described e Connect the male TX cable connector the female TX port e Connect the male RX cable connector to the female RX port Connect the fiber cables to the remote CSEFE10xx 10x media converter as described e Connect the male TX cable connector the female RX port e Connect the male RX cable connector to the female TX port Connect the fiber cable to the remote media converter as shown Connect the fiber cable to the local media converter as shown a f Install the Copper Cable NOTE The MDI straight through or MDI X crossover cable connection is configured automatically according to the network conditions 1 Locate or build 10 100Base TX copper cables with male RJ 45 connectors installed at both ends Connect the RJ 45 connector at one end of the cable to the RJ 45 port on the CSEFE10xx 10x media converter Connect the RJ 45 connector at the other end of the cable to the RJ 45 port on the other device switch workstation etc Oran sue RJ 45 port on the media converter RJ 45 port on the other device switch work station etc 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Operation Status LEDs Use the status LEDs to monitor the CSEFE10xx 10x media converter operation in the network F TP On Connection to the external AC or DC power PWR Power F ACT Fiber Activity Blinking Data reception on the
2. fiber link C F 100 Fiber Speed On Fiber link at 100 Mb s a 1q 00L E Ol z F 10 Fiber Speed On Fiber link at 10 Mb s TP ACT Copper Activity Blinking Data reception on the twisted pair copper link dL 001 49 OL H TP 100 Copper Speed On Copper link at 100 Mb s TP 10 Copper Speed On Copper link at 10 Mb s AutoCross The AutoCross feature allows either straight through MDI or crossover MDI X cables to be used when connecting to devices such as hubs transceivers or network interface cards NICs AutoCross determines the characteristics of the cable connection and automatically configures the unit to link up regardless of the cable configuration NOTE The CSEFE10xx 10x series media converter does NOT support rate conversion between 10Mb s and 100Mb s network devices ACT 100 10 O CSEFE100 techsupport transition com Click the Transition Now link for a live Web chat CSEFE1 0xx 10x Operation Continued SNMP Use SNMP at an attached terminal or at a remote location to monitor the media converter by monitoring e Media converter power e Copper link status e Fiber link status e Copper receive status e Fiber receive status e Link Pass Through status e Media converter speed Also use SNMP to enter network commands that e Enable disable Link Pass Through e Set the speed to 100 Mb s or 10 Mb s e Power down the media converter See the on l
3. 00 1310 nm single mode Fiber optic Transmitter Power min 15 0 dBm max 8 0 dBm Fiber optic Receiver Sensitivity min 32 0 dBm max 5 0 dBm Link Budget 17 0 dB CSEFE1015 100 1310 nm single mode Fiber Optic Transmitter Power min 8 0 dBm max 2 0 dBm Fiber Optic Receiver Sensitivity min 34 0 dBm max 5 0 dBm Link Budget 26 0 dB CSEFE1022 100 1310 nm single mode Fiber Optic Transmitter Power min 8 0 dBm max 2 0 dBm Fiber Optic Receiver Sensitivity min 34 0 dBm max 5 0 dBm Link Budget 26 0 dB CSEFE1029 100 1310 nm TX 1550 nm RX simplex Fiber optic Transmitter Power min 14 0 dBm max 8 0 dBm Fiber optic Receiver Sensitivity min 33 0 dBm max 3 0 dBm Link Budget 19 0 dB CSEFE1029 101 1550 nm TX 1310 nm RX simplex Fiber optic Transmitter Power min 14 0 dBm max 8 0 dBm Fiber optic Receiver Sensitivity min 33 0 dBm max 3 0 dBm Link Budget 19 0 dB The fiber optic transmitters on this device meet Class I Laser safety requirements per IEC 825 CDRH standards and comply with 21 CFR1040 10 and 21CFR1040 11 techsupport transition com Click the Transition Now link for a live Web chat 7 CSEFE1 0xx 10x Technical Specifications For use with Transition Networks Model CSEFE10xx 10x or equivalent Standards IEEE 802 3 10Base T 100Base TX 100Base FX Data Rate 10 Mb s 100 Mb s Dimensions 3 4 x 0 87 x 5 86 mm x 22 mm x 182 mm Weight 3 oz 91 g approximate Power Cons
4. 0x media converter in a 10Mb s network Install the Slide In Module CAUTION Slots in the PointSystem chassis without a slide in module installed MUST have a protective plate covering the empty slot for Class A and or Class B compliance To install the CSEFE10xx 10x media converter slide in module 1 Locate an empty installation slot on the PointSystem chassis 2 Carefully slide the slide in module into the installation slot aligning the module with the installation guides 3 Ensure that the module is firmly seated against the back of the chassis 4 Push in and rotate the panel fastener screw attached to the slide in module to secure the module to the chassis front panel fastener screw Power the Media Converter The CSEFE10xx 10x slide in module is powered through the Transition Networks PointSystem chassis 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 techsupport transition com Click the Transition Now link for a live Web chat 3 CSEFE10xx 10x Installation Continued Install the Fiber Cable The CSEFE10xx 10x is designed to be installed in pairs over the fiber link where one is the local media converter and the other is the remote 1 Locate or build fiber optic cable with male two stranded TX to RX connectors installed at both ends Connect the fiber cables to the local CSEFE10xx 10x media converter as
5. NE NETWORK Failure to observe this caution could result in damage to the public telephone network Der Anschluss dieses Ger tes an ein ffentlickes Telekommunikationsnetz in den EG Mitgliedstaaten verst sst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten ber Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer Konformit t Trademark Notice All trademarks and registered trademarks are the property of their respective owners Copyright Restrictions 2005 Transition Networks All rights reserved No part of this work may be reproduced or used in any form or by any means graphic electronic or mechanical without written permission from Transition Networks Printed in the U S A 33317 A
6. TRANSITION networks User s Guide CSEFE10xx 10x Slide in Module Media Converter e Switchable Ethernet and Fast Ethernet e 10 Mb s Copper to Fiber e 100 Mb s Copper to Fiber Transition Networks CSEFE10xx 10x series Ethernet Fast Ethernet media converter is designed to be installed in a Transition Networks PointSystem chassis and is a 10Mbps or 100Mbps switch selectable media converter Both the copper and fiber links operate at the same speed setting via a hard set with a dip switch so the media converter operates at either 10 Mb s copper to fiber or 100 Mb s copper to fiber Part Number Port One Twisted Pair Port Two Fiber Optic Copper CSEFE1012 100 R 45 100 m 328 ft ST 1310 nm single mode duplex fiber 20 km 12 4 miles CSEFE1014 100 R 45 100 m 328 ft SC 1310 nm single mode duplex fiber 20 km 12 4 miles CSEFE1015 100 RJ 45 100 m 328 ft SC 1310 nm single mode duplex fiber 40 km 24 8 miles CSEFE1022 100 RJ 45 100 m 328 ft ST 1310 nm single mode duplex fiber 40 km 24 8 miles CSEFE1029 100 RJ 45 100 m 328 ft SC 1310 mn TX 1550 nm RX single fiber 20 km 12 4 miles CSEFE1029 101 RJ 45 100 m 328 ft SC 1550 mn TX 1310 nm RX single fiber 20 km 12 4 miles The CSEFE10xx 10x media converter is designed to be installed in pairs where one is the local media converter and the other is the remote For example a local CSEFE1011 100 converter is connected via fibe
7. accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at the user s own expense Canadian Regulations This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications Le pr sent appareil num rique n met pas de bruits radio lectriques d passant les limites applicables aux appareils num riques de la Class A prescrites dans le R glement sur le brouillage radio lectrique dict par le minist re des Communications du Canada European Regulations Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures Achtung Dieses ist ein Ger t der Funkst6rgrenzwertklasse A In Wohnbereichen k nnen bei Betrieb dieses Ger tes Rundfunkstorungen auftreten In diesem Fall ist der Benutzer f r Gegenma nahmen verantwortlich Attention Ceci est un produit de Classe A Dans un environment domestique ce produit risque de cr er des interf rences radio lectriques il appartiendra alors l utilsateur de prende les measures sp cifiques appropri es CAUTION RJ connectors are NOT INTENDED FOR CONNECTION TO THE PUBLIC TELEPHO
8. ble Switch 1 sets the Link Pass Through feature Speed up 100 Mb s up Enable Link Pass Through down Disable Link Pass Through I 2 Link Pass Through is a troubleshooting feature that allows the media converter to monitor both the fiber and copper RX receive ports for loss of signal In the event of a loss of an RX signal on one media port the media converter will automatically disable the TX transmit signal of the other media port thus passing through the link loss This feature prevents the loss of valuable data unknowingly transmitted over an invalid link media converter A media converter B disables the fiber TX link loses the fiber RX link Near End i WME Far End Device Ks Converter A Converter B A Device original fault media converter B on the copper link disables the copper link Installation Continued Set the Speed switch 2 Link Pass Through up Enable Switch 2 sets the speed for both the twisted pair Speed up 100 Mb s copper and fiber links up copper and fiber links are at 1O0Mb s down copper and fiber links are at 10 Mb s NOTE The CSEFE10xx 10x media converters are fully compliant with 10Base T 100Base TX and 100Base FX standards and therefore can be connected to any compliant 10Base T 100Base TX and 100Base FX devices The CSEFE10xx 10x media converters are NOT 10Base FL compliant and therefore must be connected to another CSEFE10xx 1
9. e Does the grounded AC outlet provide power e Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 YES e Go to step 2 Is the F ACT LED illuminated NO e Check the fiber cables for proper connection e Verify that the TX and RX cables on the media converter are connected to the RX and TX ports respectively on the other media converter e Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 YES e Go to step 3 Is the F ACT LED blinking NO e If there is no activity on the fiber port go to step 4 e If there is activity on the fiber port disconnect and reconnect the fiber cable to restart the initialization process e Restart the workstation to restart the initialization process e Contact Tech Support 1 800 260 1312 Int l O00 1 952 941 7600 YES e Go to step 4 Are the F 100 and or the TP 100 LEDs illuminated YES e The media converter is set to 100Mb s for both the copper fiber links If this is not the correct speed carefully remove the media converter from the chassis and set switch 1 to down speed 10 Mb s e Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 NO e Go to step 5 Are the F 10 and or the TP 10 LEDs illuminated YES e The media converter is set to 10 Mb s for the copper and fiber links If this is not the correct speed carefully remove the media converter from the chassis and set switch 2 to up speed 100 Mb s e Contact Tech Suppor
10. est Parkway Minneapolis MN 55344 USA telephone 952 941 7600 toll free 800 526 9267 fax 952 941 2322 Wee oe Declaration of Conformity Name of Mfg Transition Networks 6475 City West Parkway Minneapolis MN 55344 USA Model CSEFE10xx 10x Series Media Converters Part Number s CSEFE1012 100 CSEFE1014 100 CSEFE1015 100 CSEFE1022 100 CSEFE1029 100 CSEFE1029 101 Regulation EMC Directive 89 336 EEC Purpose To declare that the CSEFE10xx 10x to which this declaration refers is in conformity with the following standards CISPR 22 1993 EN55022 1998 Class A FCCPart 15 Subpart B EN 55024 1998 EN 61000 3 2 1995 EN 61000 3 3 1995 21 CFR Subpart J I the undersigned hereby declare that the equipment specified above conforms to the above Directive s and Standard s SS ee Te December 6 2004 Stephen Anderson Vice President of Engineering Date techsupport transition com Click the Transition Now link for a live Web chat 11 Compliance Information CISPR22 EN55022 Class A EN55024 CE Mark FCC Regulations This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to part 15 of the FCC rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in
11. ine documentation that comes with Transition Networks FocalPoint software for applicable commands and usage Cable Specifications Copper Cable Category 3 Minimum requirement for 10 Mb s operation Gauge 24 to 22 AWG Attenuation 11 5 dB 100m 5 10 MHz Category 5 Minimum requirement for 100 Mb s operation Gauge 24 to 22 AWG Attenuation 22 0 dB 100m 100 MHz e Straight through or crossover copper cable may be used e Shielded STP or unshielded UTP twisted pair cable may be used e Pins 1 amp 2 and 3 amp 6 are the two active pairs in an Ethernet network e RJ 45 Pin out Pin 1 TD Pin 2 TD Pin 3 RD Pin 6 RD e Use only dedicated wire pairs for the active pins e g blue white amp white blue orange white amp white orange etc e Do not use flat or silver satin wire Straight Through Cable Crossover Cable 1 1 l l 1 1 Twisted Pair 1 j 9 Twisted Pair 1 9 9 Twisted Pair 2 Twisted Pair 2 f 6 6 6 6 6 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Cable Specifications The physical characteristics must meet or exceed IEEE 802 3 specifications Fiber Cable Bit Error Rate lt 10 9 Single mode 9 um CSEFE1012 100 1310 nm single mode Fiber optic Transmitter Power min 15 0 dBm max 8 0 dBm Fiber optic Receiver Sensitivity min 32 0 dBm max 5 0 dBm Link Budget 17 0 dB CSEFE1014 1
12. r to a remote CSEFE1011 100 converter For a single fiber network a local CSEFE1029 100 is connected via fiber to a remote CSEFE1029 101 converter Typical maximum cable distance Installation 2 Actual distance is dependent upon the Operation 05 5 physical characteristics of the network Cable Specifications 6 TX transmit RX receive Technical Specifications 8 Troubleshooting 9 Compliance Information 12 CSEFE10xx 10x Installation Set Link Pass Through switch 1 CAUTION Wear a grounding device and observe electrostatic discharge precautions when setting the jumper or when installing the media converter Failure to observe this caution could result in damage to and subsequent failure of the media converter Set the Hardware Software Jumper e The hardware software jumper J2 is located on J2 the circuit board H fee S e Use small needle nose pliers to move the jumper hardware mode to the desired position Hardware The media converter mode is determined by 2 the switch settings see below H ke s Software The media converter mode is determined by software mode the most recently saved on board microprocessor settings The Link Pass Through and speed switches are located on the side of the media converter Use a small screwdriver to set the recessed switches Link Pass Through up Ena
13. t 1 800 260 1312 Int l O00 1 952 941 7600 NO e Go to step 6 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 techsupport transition com Click the Transition Now link for a live Web chat CSEFE1 0xx 10x Troubleshooting Continued Is the TP ACT LED illuminated NO e Check the twisted pair copper cables for proper connection e Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 YES e Go to step 7 Is the TP ACT LED blinking NO e If there is activity on the copper port disconnect and reconnect the copper cable to restart the initialization process e Restart the workstation to restart the initialization process e Contact Tech Support 1 800 260 1312 Int l 00 1 952 941 7600 10 24 Hour Technical Support 1 800 260 1312 International 00 1 952 941 7600 Contact Us Technical Support Technical support is available 24 hours a day US and Canada 1 800 260 1312 International 00 1 952 941 7600 Transition Now Chat live via the Web with Transition Networks Technical Support Log onto www transition com and click the Transition Now link Web Based Seminars Transition Networks provides seminars via live web based training Log onto www transition com and click the Learning Center link E Mail Ask a question anytime by sending an e mail to our technical support staff techsupport transition com Address Transition Networks 6475 City W
14. umption 3 6 watts Tmra 0 to 50 C 32 to 122 F Storage Temperature 20 to 85 C 4 to 185 F Humidity 5 to 95 non condensing Altitude O to 10 000 feet Warranty Lifetime Environment Manufacturer s rated ambient temperature Tmra range for this slide in module depends on the physical characteristics and the installation configuration of the Transition Networks PointSystem chassis in which this slide in module will be installed NOTE The information in this user s guide is subject to change For the most up to date information on the CSEFE10xx 10x media converter view the user s guide on line at www transition com The stand alone version of the media converter is the SSEFE10xx 10x model For more information see the SSEFE10Oxx 10x user s guide on line at www transition com Product is certified by the manufacturer to comply with DHHS Rule 21 CFR Subchapter J applicable at the date of manufacture CAUTION Visible and invisible laser radiation when open Do not stare into beam or view directly with optical instruments CAUTION Use of controls adjustments or the performance of procedures other than those specified herein may result in hazardous radiation exposure Troubleshooting 1 Is the PWR LED on the media converter illuminated NO e Is the media converter inserted properly into the chassis e Is the power cord properly installed in the chassis and in the grounded AC outlet

Download Pdf Manuals

image

Related Search

Related Contents

South Shore Furniture 3159290 Instructions / Assembly  User Manual Armadillo 9X Series Models  HP OFFICEJET 7300 User's Manual  Backpaddock mobile user manual  Sony ICF-C255RC Marketing Specifications  Speco NVR User Manual  OpenWRT User Manual  CT20 Installation Instructions  Manual de usuario del Registro de participantes en el  Philips 5.1 Home theater HTS6593  