1.     DOWN Disables Auto Negotiation on the copper port     2  Copper Mode    Applies only if switch 1 is DOWN     UP Forces full duplex operation on the copper port   DOWN Forces half duplex operation on the copper port     3  Speed   Applies only if switch 1 is DOWN    UP Forces 100 Mb s operation on the copper port     DOWN Forces 10 Mb s operation on the copper port     4  Fiber Mode  UP Forces full duplex operation on the fiber port   DOWN Forces half duplex operation on the fiber port              2 Tech Support  800 260 1312 International  952 941 7600 7am 6pm CST  GMT 6 00     INSTALLATION    Continued  Set the Jumpers    The jumpers are located on the Media Converter circuit board  Use small  needle nosed pliers or a similar device to set the jumper     The Hardware Software jumper is labeled    H    for hardware and    S    for  software  see the drawing below   s oG    Hardware The Media Converter mode is determined by ERETTE    the 4 position switch settings listed above   Software The Media Converter mode is determined by eNe H   the most recently saved  on board   microprocessor settings  Software Mode    The Far End Fault jumper is labeled    FE    for enable Far End Fault and    FD     for disable Far End Fault  see the drawing below   Rao Fp    Enable A fault on the fiber link causes the Media      Enable Far End Fault  Converter to transmit a Far End Fault signal     Disable No Far End Fault signal is transmitted when a  fault occurs     FE    ome  FD    Disab
2.  AWG    11 5 dB 100m   5 10 MHz  Category 5   REQUIRED for 100 Mb s operation     24 to 22 AWG    22 0 dB  100m   100 MHz  e Straight Through Twisted Pair cable must be used     Fiber Cable Standards IEEE 802 3     Bit Error Rate   lt 10 9 Data Rate  10 Mb s  100 Mb s  Singlemode fiber  recommended   9 um     i P    Multimode fiber  recommended   62 5 125 pm Dimensions 3 4  x 4 7  x 0 87   86 mm x 119 mm x 22 mm   Multimode fiber  optional   100 140  85 140  50 125 um Weight 4 oz   114 g   approximate   CBFTF1011 150  CBFTF1013 150 multimode Power Consumption  4 0 W  Fiber Optic Transmitter Power  min   19 0 dBm max   14 0 dBm  Fiber Optic Receiver Sensitivity  min   30 0 dBm max   14 0 dBm MTBF 629 677 hours  MIL217F2 V5 0   MIL HDBK 217F   Link Budget  11 0 dB 1 630 181 hours  Bellcore7 V5 0   CBFTF1014 150 singlemode Packet Size  Unicast MAC address  128K bytes  1 Mbit   Fiber optic Transmitter Power  min   15 0 dBm max   8 0 dBm Maximum packet size  1522 bytes  Fiber optic Receiver Sensitivity  min   31 0 dBm max   8 0 dBm Memorv  1K bytes  l y  y  Link Budget  16 0 dB    nee oel 4 Environment Tmra   O to 60  C  32 to 140  F      singiemode     e          Fiber optic Transmitter Power  min   8 0 dBm max   2 0 dBm ta von oe ak   o    Fiber optic Receiver Sensitivity  min   34 0 dBm max   7 0 dBm A Hy E EEEE   Link Budget  26 0 dB Altitude 0 1 0 000 feet  CBFTF1018 150 multimode Warranty Lifetime  sedi ee Power    Ta  19 0 au a bee ae  Manufacturer   s rated ambient tempera
3.  If the result is less than or equal to 512 BT  the path is good     For more information on the 512 Bit Rule  see the white paper titled    Collision  Domains    on the Transition Networks website at     http   www  transition com learning whitepapers colldom_wp htm    Using SNMP    See the on line documentation that comes with Transition Networks  FocalPoint    software for applicable commands and usage     Use SNMP at an attached terminal or at a remote location to monitor the  Media Converter by monitoring    e Media Converter power   e   Copper and fiber link status   e   Copper and fiber duplex mode   e Copper port speed   e Hardware switch setting    Also  use SNMP to enter network commands that   e   Enable disable Auto Negotiation on Copper  e Force 10Mb s or 100Mb s on copper  e Force full duplex or half duplex on copper  e Force full duplex or half duplex on fiber  e   Enable disable Far End Fault on fiber          6    Tech Support  800 260 1312 International  952 941 7600 7am 6pm CST  GMT 6 00     techsupport transition com    Select the    Transition Now    Link for a Live Web Chat 7    CBFTF10xx 15x          CABLE SPECIFICATIONS    The physical characteristics must meet or exceed IEEE 802 3    specifications     TECHNICAL SPECIFICATIONS    For use with Transition Networks Model CBFTF10xx 15x or equivalent     Copper Cable Maximum Cable Distance  100 meters    Category 3   May be used for 10 Mb s operation     Gauge  Attenuation    Gauge  Attenuation    24 to 22
4.  an ein Offentlickes Telekommunikationsnetz in den EG   Mitgliedstaaten verstdsst gegen die jeweligen einzelstaatlichen Gesetze zur Anwendung der  Richtlinie 91 263 EWG zur Angleichung der Rechtsvorschriften der Mitgliedstaaten   ber  Telekommunikationsendeinrichtungen einschliesslich der gegenseitigen Anerkennung ihrer  Konformitat     Trademark Notice   All trademarks and registered trademarks are the property of their respective owners   Copyright Restrictions      2002 2003 Transition Networks    All rights reserved  No part of this work may be reproduced or used in any form or by any  means   graphic  electronic  or mechanical   without written permission from Transition  Networks     Printed in the U S A  33226 B       
5.  is  likely to cause harmful interference  in which case the user will be required to correct the  interference at the user s own expense    Canadian Regulations   This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus  set out on the radio interference regulations of the Canadian Department of Communications   Le pr  sent appareil num  rique n   met pas de bruits radio  lectriques d  passant les limites  applicables aux appareils num  riques de la class A prescrites dans le Reglement sur le  brouillage radio  lectrique   dict   par le minist  re des Communications du Canada     European Regulations   Warning This is a Class A product  In a domestic environment this product may cause radio  interference in which case the user may be required to take adequate measures    Achtung  Dieses ist ein Ger  t der Funkstorgrenzwertklasse A  In Wohnbereichen k  nnen  bei Betrieb dieses Ger  tes Rundfunkstorungen auftreten  in weichen Fallen der Benutzer f  r  entsprechende Gegenmafsnahmen werantwortlich ist    Attention  Ceci est un produit de Classe A  Dans un environment domestique  ce produit  risque de cr  er des interf  rences radio  lectriques  il appartiendra alors a I utilsateur de  prende les measures sp  cifiques appropri  es     CAUTION  RJ connectors are NOT INTENDED FOR CONNECTION TO THE  PUBLIC TELEPHONE NETWORK  Failure to observe this caution could result in  damage to the public telephone network     Der Anschluss dieses Ger  tes
6. 16 6                8 Tech Support  800 260 1312 International  952 941 7600 7am 6pm CST  GMT 6 00  techsupport transition com    Select the    Transition Now    Link for a Live Web Chat 9    CBFTF10xx 15x       FAULT ISOLATION AND RECOVERY    If the Media Converter fails  isolate and correct the failure by determining the  answers to the following questions and then taking the indicated action     1     Is the power LED on the Media Converter illuminated    NO   e  s the media converter inserted properly into the chassis    e Is the power cord properly installed in the chassis and at the external  power source and does the external power source provide power    e Contact Technical Support  US Canada  1 800 260 1312   International  OO 1 952 941 7600    YES    e Proceed to step 2     Is the TLNK  twisted pair link  LED illuminated    NO   e Check the copper cables for proper connection and pin assignment    e Contact Technical Support  US Canada  1 800 260 1312   International  O0 1 952 941 7600    YES    e Proceed to step 3     Is the FLNK  fiber pair link  LED illuminated    NO   e Check the fiber cables for proper connection    e Verify that the TX and RX cables are connected to the RX and TX  ports  respectively  on the 100Base FX device    e Contact Technical Support  US Canada  1 800 260 1312   International  O0O 1 952 941 7600    YES    e Proceed to step 4     Is the TSPD  twisted pair speed  LED illuminated    NO   e Check the copper cables for proper connection    e 
7. 55344 USA   Model  CBFTF10xx 15x Series Media Converters   Part Number s   CBFTF1011 150  CBFTF1013 150  CBFTF1014 150  CBFTF1015 150   CBFTF1018 150  CBFTF1029 150  CBFIF1029 151  CBFTF1029 152   CBFTF1029 153   Regulation  EMC Directive 89 336 EEC    Purpose  To declare that the CBFTF10xx 15x to which this declaration refers is  in conformity with the following standards    EMC CISPR 22 1985 Class A  EN 55022 1988 Class A  EN 50082 1 1992    EN 60950 A4 1997  IEC 801 2  801 3  and 801 4  IEC 950  22 CFR subpart J       the undersigned  hereby declare that the equipment specified above conforms to the above  Directive s  and Standard s      ee ee Ee  August 8  2002    Stephen Anderson  Vice President of Engineering Date                   techsupport transition com    Select the    Transition Now    Link for a Live Web Chat    11       COMPLIANCE INFORMATION    UL Listed   C UL Listed  Canada   CISPR22 EN55022 Class A  CE Mark    FCC Regulations   This equipment has been tested and found to comply with the limits for a class A digital  device  pursuant to part 15 of the FCC rules  These limits are designed to provide reasonable  protection against harmful interference when the equipment is operated in a commercial  environment  This equipment generates  uses  and can radiate radio frequency energy and  if  not installed and used in accordance with the instruction manual  may cause harmful  interference to radio communications  Operation of this equipment in a residential area
8. Off   The Media Converter has selected 10Mb s operation    e If the speed is not correct  disconnect and reconnect the twisted pair  cable to restart the initialization process    e Contact Technical Support  US Canada  1 800 260 1312   International  OO 1 952 941 7600     e On   The Media Converter has selected 100Mb s operation    e If the speed is not correct  disconnect and reconnect the twisted pair  cable to restart the initialization process    e Contact Technical Support  US Canada  1 800 260 1312   International  O0O 1 952 941 7600           10 Tech Support  800 260 1312 International  952 941 7600 7am 6pm CST  GMT 6 00     CONTACT US    Technical Support  Technical support is avialable 7 00 AM   6 00 PM CST  GMT  6 00   US and Canada  1 800 260 1312  International  00 1 952 941 7600    Transition Now  Chat live via the Web with Transition Networks Technical Support   Log onto www transition com and click the Transition Now link     Web Based Seminars  Transition Networks provides seminars via live web based training     Log onto www transition com and click the Learning Center link     E Mail    Ask a question anytime by sending an e mail to our technical support staff     techsupport transition com    Address  Transition Networks  6475 City West Parkway  Minneapolis  MN 55344  USA  telephone  952 941 7600  toll free  800 526 9267  fax  952 941 2322       DECLARATION OF CONFORMITY    oe aves   Name of Mfg  Transition Networks  6475 City West Parkway  Minneapolis MN 
9. TRANSITION    Nees networks       USER   S GUIDE  CBFTF10xx 15x    Slide in Module Media Converter   e Copper to Fiber   e 10 100 Bridging  2 Port    e 10Base T 100Base TX to 100Base FX    The CBFTF10xx 15x 2 port Ethernet Fast Ethernet  bridging Media Converter is designed to be  installed in a Transition Networks PointSystem     chassis and connects 10Base T Ethernet or  100Base TX Fast Ethernet twisted pair copper  network devices to network devices on a 100Base   FX Fast Ethernet fiber network        Part Number Port One   Copper  10Base T 100Base TX    CBFTF1011 150 RJ 45   100 m  328 ft    CBFTF1013 150 RJ 45   100 m  328 ft      CBFTF1014 150 RJ 45   100 m  328 ft    CBFTF1015 150 RJ 45   100 m  328 ft      CBFTF1018 150 RJ 45  100 m  328 ft      CBFTF1029 150    RJ 45  100 m  328 ft      CBFTF1029 151     R  45  100 m  328 ft      CBFTF1029 152    R  45  100 m  328 ft      CBFTF1029 153    RJ 45  100 m  328 ft      Port Two   Duplex Fiber Optic  100Base FX    ST  1300 nm multimode   2 km  1 2 miles     SC  1300 nm multimode   2 km  1 2 miles     SC  1310 nm singlemode  20 km  12 4 miles      SC  1310 nm singlemode  40 km  24 8 miles      MT RJ  1300 nm multimode  2 km  1 2 miles      SC  1310 mn  TX  1550 nm  RX   singlemode  20 km  12 4 miles      SC  1550 mn  TX  1310 nm  RX   singlemode  20 km  12 4 miles       SC  1310 mn  TX  1550 nm  RX   singlemode  40 km  24 8 miles       SC  1550 mn  TX  1310 nm  RX   singlemode  40 km  24 8 miles         Typical maximum cabl
10. e distance   Actual distance is dependent upon the  physical characteristics of the network    TX    transmit  RX    receive        SBFIF1029 150 and SBFIF1029 151 are intended to be installed in the same  network where one is the local converter and the other is the remote    converter         SBFTF1029 152 and SBFIF1029 153  are intended to be installed in the same  network where one is the  ocal  converter and the other is the remote  converter           Halan seic a oat ame eaaet 2  OPTA aeaaea a 5  Cable Specifications             8  Technical Specifications          9    Fault Isolation and Correction   10  Compliance Information         12             CBFTF10xx 15x       INSTALLATION    CAUTION  Wear a grounding device and observe electrostatic discharge  precautions when setting the 4 position switch and the jumper s  and when  installing the Slide in Module  Failure to observe this caution could result in  damage to  and subsequent failure of  the Media Converter     Set the 4 Position Switch Auto Negotiation  UP Enabled   The 4 position switch is located on the ie  side of the Media Converter  Use a Speed  UP 100Mb s   small flatblade screwdriver or a similar Fiber Mode  device to set the recessed switches  Te om  UP Full Duplex   Refer to the drawing for the locations  of the four individual switches        1  Auto Negotiation   UP Enables Auto Negotiation on the copper port   Advertises 100 Mb s full duplex and half duplex   and 10 Mb s full duplex and half duplex
11. figuration   This feature does not require operator intervention      Far End Fault    When the Far End Fault feature is activated  a fault on an incoming fiber link  causes the Media Converter to transmit a Far End Fault signal on the outgoing  fiber link  In addition the Far End Fault signal also activates the Link Pass   Through  which  in turn  disables the link on the copper portion of the  network              _ r S          Da    Copper Fiber   Copper   aarti        En   Sends a Far End    we te Fault  Media Converter ee  ee  Sends a Far End ee es    Fault         100Base TX   ab C   100Base FX    Device   et CRE a Device    ooa ee       Media Converter Media Converter       Sie ee ee ee    OPERATION   Continued    Product Features   Continued    Full Duplex Network    In a full duplex network  maximum cable lengths are determined by the type  of cables that are used  See page 1  front cover  for the cable specifications  for the different CBFTF10xx 15x models     The 512 Bit Rule does not apply in a full duplex network     Half Duplex Network  512 Bit Rule     In a half duplex network  the maximum cable lengths are determined by the  round trip delay limitations of each Fast Ethernet collision domain   A  collision domain is the longest path between any two terminal devices  e g  a  terminal  switch  or router      The 512 Bit Rule determines the maximum length of cable permitted by  calculating the round trip delay in bit times  BT  of a particular collision  domain 
12. le Far End Fault    Installing the Slide In Module    CAUTION  Slots in the PointSystem    Chassis without a Slide in Module   installed MUST have a protective plate covering the empty slot for Class A   and or Class B compliance    To install the CGETF10xx 15x Media Converter Slide in Module    1  Locate an empty installation slot on the PointSystem    Chassis    2  Carefully slide the Slide in Module into the installation slot  aligning the  Slide in Module with the installation guides    3  Ensure that the Slide in Module is firmly seated against the back of the  chassis    4  Secure the Slide in Module by securing the panel fastener screw   attached to the Slide in Module  to the chassis front                                   Panel Fastener Screw       techsupport transition com    Select the    Transition Now    Link for a Live Web Chat 3    CBFTF10xx 15x       INSTALLATION    Continued  Install the Twisted Pair Copper Cable    f     Locate or build IEEE 803 2    compliant 10Base T or 100Base TX cables   with straight through RJ 45 cable  and with straight through RJ 45  connectors installed at both ends    Connect the RJ 45 connector at one end of the cable to the RJ 45 port  connector on the Media Converter     Connect the RJ 45 connector at the other end of the cable to the RJ 45  port connector on the other device  switch  workstation  etc       NOTE  The MDI  straight through  or MDI X  crossover  cable connection is  configured automatically  according to the netw
13. n to external AC power   TSPD  Twisted Pair Speed   ON   100 Mb s   Blinking   10 Mb s   TDPX  Twisted Pair Duplex   ON   full duplex copper connection   LED off   half duplex copper connection   TLKN Twisted Pair Link   ON   copper link connection     Blinking   copper network activity        FDPX FLNK PWR    O O        TSPD TDPX TLNK       x lt     XAj ese A001       vs    gt  lt           xl   seg00L 0      i    CBF TETS0       techsupport transition com    Select the    Transition Now    Link for a Live Web Chat    CBFTF10xx 15x          OPERATION   Continued    a ee ee ee a    Product Features    Auto Negotiation    The Auto Negotiation feature allows the Media Converter to be used with  10Base T and 100Base TX twisted pair ports  Using Auto Negotiation  the  Media Converter brings up the copper links in the highest speed and mode  possible for all the attached network devices     If selected  Auto Negotiation allows a twisted pair link to become operational  only after the Auto Negotiation function matches network speed capabilities  at both ends of the twisted pair copper segment     Autocross    The AutoCross    feature  when selected  allows either straight through  MDI   or crossover  MDI X  cables to be used when connecting to 10Base TX or  100Base TX devices  such as hubs  transceivers  or network interface cards   NICs   AutoCross determines the characteristics of the cable connection and  automatically configures the unit to link up  regardless of the cable  con
14. ork conditions     on the Media        RJ 45 port RJ 45 port  on the other device     switch  work station  etc         Converter    Install the Fiber Cable    l     Locate or build IEEE 803 2    compliant 100Base FX fiber cable with  male  two stranded TX to RX connectors installed at both ends    Connect the fiber cables to the CBFTF10xx 15x Media Converter as  described    e Connect the male TX cable connector the female TX connector    e Connect the male RX cable connector to the female RX connector   Connect the fiber cables to the other device  another Media Converter   hub  etc   as described    e Connect the male TX cable connector the female RX connector    e Connect the male RX cable connector to the female TX connector         Connect the fiber cable  to the other device   media converter    hub  etc   as shown    Connect the fiber cable  to the Media Converter  as shown        RX  TX                      4    Tech Support  800 260 1312 International  952 941 7600 7am 6pm CST  GMT 6 00     INSTALLATION    Continued    Power the Media Converter    The CBFTF10xx 15x Slide in Module Media Converter is powered through the    Point System    chassis     OPERATION    Status LEDs    Use the status LEDs to monitor the Media  Converter and the network connections     FDPX  Fiber Duplex   ON   full duplex fiber connection   Blinking   half duplex fiber connection   FLNK  Fiber Link   ON   fiber link connection   Blinking   fiber network activity   PWR  Power   ON   connectio
15. ture  Tmra range for this Slide In Module  eee See oes ae aa uu EA depends on the physical characteristics and the installation configuration of the      l Transition Networks PointSystem    chassis in which this Slide In Module will be  CBFTF1029 150  CBFTF1029 151 singlemode installed  Fiber optic Transmitter Power  min   13 0 dBm max   6 0 dBm  Fiber optic Receiver Sensitivity  min   32 0 dBm max   3 0 dBm Product is certified by the manufacturer to comply with DHHS Rule 21 CFR   Link Budget  19 0 dB Subchapter J applicable at the date of manufacture   rae  BPTF 1023 193 alge mode l CAUTION  Visible and Invisible Laser Radiation When Open  Do Not Stare  Fiber optic Transmitter Power  min   8 0 dBm max   3 0 dBm I B Or View Di lv With Optical    Fiber optic Receiver Sensitivity  min   33 0 dBm max   3 0 dBm nto Beam Or View Directly With Optical Instruments   Link Budget  25 0 dB CAUTION  Use of controls  adjustments or the performance of procedures    other than those specified herein may result in hazardous radiation exposure     e Shielded Twisted Pair  STP  OR Unshielded Twisted Pair  UTP  may be used   e Pins 1 amp 2 and 3 amp 6 are the two active pairs in an Ethernet network    e Use only dedicated wire pairs for the active pins    e g   blue white  amp  white blue  orange white  amp  white orange  etc    e Do not use flat or silver satin wire     Straight Through Cable                                                 1 1  Twisted Pair  1 5 9  Twisted Pair  2          
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
stapile3 - Stewart Technology Associates  Frew Oasys GEO Suite for Windows  取り扱い説明書 GPZ900R / ZEPHYR1100(輸出仕様) 常時  July 2008  - Virus Bulletin  rq 1 - Communauté d`agglomération du Val d`Orge  ASSMANN Electronic DN-19 ORG-47U-SW rack accessory    2003年度 アート・リサーチセンタープロジェクト研究計画書  取扱説明書 ペイントライン引き 品番:  79120100 型式:EST798  here - Steam Vac Australia    Copyright © All rights reserved. 