Home
Torus Power conditioner rm 2.5 power conditioner User's Manual
Contents
1. 15 Damage Requiring Service The device should be serviced by licensed technicians when e The plug or power supply cord has been damaged e Objects have fallen or liquid has spilled inside the device e The device has been exposed to moisture e The device does not appear to be operating properly or exhibits a marked change in performance e The device has been dropped or the enclosure becomes damaged 16 Service The device should always be serviced by licensed technicians Only replacement parts specified by the manufacturer should be used The use of unauthorized substitutions may result in fire shock or other hazards 17 Do not position the equipment so that it is difficult to operate the disconnecting device power cord 18 If the equipment is used in a manner not specified by the manufacturer the protection provided by the equipment may be impaired www TorusPower com Rack Mount Standalone 10 07 D ibti Torus Power PIUs Power Isolation Units combine the best surge suppression with unique toroidal transformer technologies from PLITRON to provide the ultimate in AC power conditioning and protection for sensitive audio and video equipment applications PIUs use ZeroSurge patented series mode surge removal filters to absorb dangerous voltage surges and safely dissipate them without using failure prone MOVs metal oxide varistors Also unlike MOV based protection voltage surges are not shunted to
2. Owner s Manual Power Conditioners Audio Video Power Isolation Units Rack Mount Standalone Model Number Description Input Output Connector 4 outlets RM 2 5 Single 2 5A 120V Medical grade Important Safety Instructions CAUTION To reduce the risk of electric shock and fire do not remove the cover of this device There are no user serviceable parts inside Please refer all servicing to licensed service technicians CAUTION The international symbol of a lightning bolt inside a triangle is intended to alert the user to uninsulated dangerous voltage within the device s enclosure The international symbol of an exclamation point inside a triangle is intended to alert the user to the presence of important operating maintenance and servicing information in the manual accompanying the device CAUTION To prevent electrical shock match wide blade of plug to wide slot fully insert CAUTION To reduce the risk of electrical shock do not expose this equipment to rain or moisture CAUTION To reduce the risk of electrical shock ensure the voltage selector switch is selected to the appropriate supply voltage CAUTION To reduce the risk of electrical shock ensure the fuses are replaced with the appropriate fuse according to the unit markings 1 Read Instructions All safety and operating instructions should be read before operating the device 2 Retain Instructions The safety and operating instructions shoul
3. d be retained for future reference 3 Heed Warnings All warnings on the device and in the operating instructions should be adhered to 4 Follow Instructions All operating and safety instructions should be followed 5 Water amp Moisture The device should never be used in on or near water for risk of fatal shock 6 Carts amp Stands The device should only be used on carts or stands recommended by the manufacturer 8 Ventilation The device should always be located in such a way that it maintains proper ventilation It should never be placed in a built in installation or anywhere that may impede the flow of air through its ventilation slots 9 Heat Never locate the device near heat sources such as radiators floor registers stoves or other heat generating devices 11 Power Cord Protection Power cables should be routed so they are not likely to be stepped on or crushed by items placed on them or against them Special attention should be paid to areas where the plug enters a socket or fused strip and where the cord exits the device 12 Cleaning The device should be cleaned in accordance with manufacturer s instructions 13 Periods Of Non Use The device should be unplugged when not being used for extended periods 14 Dangerous Entry Care should be taken that no foreign objects or liquids fall or are spilled inside the device Owner s Manual Power Conditioners Audio Video Power Isolation Units
4. enerating equipment Maintain at least 6 behind the PIU for adequate wiring space www TorusPower com Rack Mount Standalone 10 07 Front Panel Layout Illuminated Power Switch Circuit Breaker Circuit Protecti The front panel power switch is also a circuit breaker As a circuit breaker it prevents excessive current from entering the PIU When the power is on the switch is illuminated When the breaker trips the switch returns to its off position Thermal Protection _ Torus PIUs will shut down if internal unit temperature reaches excessive levels Accessory Power Outlet Removable Mounting Feet for Rack Mount Wall Receptacles Torus PIUs are high power products The outlets they are plugged into should be sufficient to provide the current to operate them without tripping circuit breakers within your junction panel Model Number Input Voltage Input Load Current Capability Input Current Nominal Current Rating Limiting 1 2 cycle 1 second 10 seconds RM 2 5 120VAC 60Hz 2 5A 25A 20A 7 5A 2 5A Range 10 voltage Circuit Breaker 57 63Hz Front Panel n 1 I s l S E fi i E Model Number Input Line Cord Suggested Output Weight Size Connector included Wall Connector w x d x h Rear Panel Receptacle Rear Panel RM 2 5 IEC 15A N5 15 14AWG Standard outlet Qty 2 4 outlets 17 Ibs 19 0 x 11 0 x 2 0 Inlet C13 15A 125V NEMA 5 15R Medical grade With m
5. ground Isolation is combined with proven proprietary technologies from PLITRON in the over sized toroidal transformer NBT works as a low pass filter using the controlled leakage inductance and capacitances within the transformer to effectively reduce noise LoNo technology has been used for years by high end audio companies who demand silent transformers UST provides additional common mode filtering Shipping Carton amp Packing Material Please keep the original shipping box and all packing material This will ensure the PIU is protected in future transport In the unlikely event you have a problem and must return it for service you must use the proper packing material Ship the PIU only in the original packing material as the unit is not insurable by carriers otherwise Owner s Manual Power Conditioners Audio Video Power Isolation Units using a highly efficient Faraday screen Low impedance output provides the most unconstrained yet protected energy source available to your equipment PI t amp Ventilati Torus Power PIUs are extremely efficient devices however they are also very high power devices and must be adequately cooled PIUs have ventilation slots on the base and the cover Maintain at least 1 distance from each of these surfaces to anything else Should your installation conditions be constricted additional forced air cooling may be necessary Do not install the PIU directly above heat g
6. ifications subject to change without notice Torus Power 2007 ZeroSurge is a registered trademark of Zero Surge Inc
7. ounting feet 15A 125V 19 0 x 11 0 x 1 75 Without mounting feet Owner s Manual Power Conditioners Audio Video Power Isolation Units www TorusPower com Rack Mount Standalone 10 07 Line Cords Standard 15A 120V Equipment end IEC C13 Plug 5 15P Straight Blade 2 pole 3 wire grounding 15A 125V Cord 3 x 14AWG Length 2 5 m Warranty Torus Power products are warranted to be free from manufacturing defects for a minimum of five years from the original date of sale This includes parts labour and return shipping to the first registered owner and all subsequent registered owners Warranty coverage is extended to applicable products registered or having proof of purchase sales invoice etc Torus Power products are marketed worldwide through Bryston Limited For sales contact jamestanner bryston ca www bryston ca 10 07 In the event of a defect or malfunction Torus Power will remedy the problem by repair or replacement as we deem necessary to restore the product to full performance This warranty is considered void if the defect malfunction or failure of the product or any component part was caused by damage not resulting from a defect or malfunction or abuse while in the possession of the customer Failure to fully comply with Torus Power operating instructions voids the warranty www tTorusPower com Torus Power PO Box 30030 Toronto ON M3J 3L6 Canada 416 667 8473 Spec