Home

Toro Lynx Central Control SE 2.0 GDC Specifications

image

Contents

1. The central controller shall have programs based on a hierarchy organized the same as the golf course Course Areas greens tees fairways etc followed by holes 1 through 48 followed by the individual sprinklers The central controller shall have the ability to view the system at any of the four levels course area hole sprinkler by Dynamic Drill down simply clicking on a plus minus box to give the user intuitive control A graphic red Water Drop will identify areas and holes that have stations turned off A graphic green Water Drop will identify areas holes and stations set to run automatically A graphic blue Water Drop will identify areas not scheduled to water The central controller shall allow the user to schedule areas to irrigate by either entering runtimes in minutes or by entering amount of water to apply If the amount is utilized the corresponding minutes will automatically be calculated and displayed If minutes are utilized the corresponding amount of application shall be calculated and displayed Runtimes shall be calculated and executed to the minute The central controller shall have a Course Report to allow the user to determine the status of each sprinkler station on the golf course The Course Report shall auto generate after each night s watering to allow confirmation of all sprinkler runtimes at a glance The Course Report will display all Automatic Manual and currently running stations
2. Dewpoint The central control shall offer a Pump Integration software option shall support up to 99 alarm responses The central controller shall provide system status information on communication with the Gate Way s and wire paths automatically and continuously without requiring alarm configuration The central controller shall provide reports detailing the following information 1 projected schedule activity 2 contents of the database constructed while programming the central controller 3 overview of scheduled irrigation activity including start time end time and area information flow and program 4 report stations that did not acknowledge a message to run The central controller shall be capable of monitoring 1 pump stations manufactured either Flowtronex Watertronics or Grundfos The central controller shall be capable of displaying flow and pressure With the Optional Pump Integration software the central controller shall be capable of responding to alarm conditions based on data received from the Flowtronex Grundfos or Watertronics pump station When alarms are activated the irrigation system will respond in one of the following ways log only no response pause irrigation resume irrigation turn a switch on off cancel a program or station initiate a rain hold or cancel start a program or initiate a Re Flow response The central controller shall have Power Guard the ability to limit electrical consumption during
3. been scheduled utilizing a Rain Re Flow alarm response The central controller shall include the Turf Guard Soil Sensor software Individual sensor data can be assigned to specific sprinklers to allow the user to view current soil moisture on the Watering Plan allowing the user to choose to skip watering if moisture levels are above user defined thresholds or to activate stations if moisture levels are below defined thresholds The central controller shall employ advanced hydraulic electrical systems management allowing the user to specify hydraulic system design source and pipes representing mainlines branches and flow groups and the hydraulic limits of each entity The central controller shall manage system flow by automatically generating the appropriate station start times based on the hydraulic limits set for each source and pipe and for the simultaneous station limit set for each wire path The central controller shall display projected flow by source course area program and hole using colors to differentiate The graph will calculate and display the maximum instantaneous flow as well as the total volume Maximum flow and volume will be displayed in user selected units When the Optional Pump integration software is configured the actual flow reported by the pump station can be displayed simultaneously with the projected flow for up to the last 7 days The central controller shall have the ability to manually start programs for an enti
4. Connect and NSN Connect Plus are trademarks of The Toro Company Microsoft and Windows are registered trademarks of Microsoft Inc
5. LYNX SE CENTRAL CONTROL FOR NETWORK GDC General Specifications Number of Gateways Up to 4 each with up to 2 Station Groups Number of decoder stations up to 500 Number of Courses 1 Number of holes per course 48 Number of holes per system 48 Number of Area Programs per system 99 Number of switch controls for automation of non irrigation functions lights fountains aerators etc 50 100 Hydraulic branches Supports up to 10 weather stations and 1 hydraulic source Area Hole Sprinkler based Program Architecture with Dynamic Drill down to individual stations Station Based Flow management for optimum system performance and reduce water time window Automated multi level hydraulic flow and electrical systems management Electro Flow Detailed color coded graphing of system projected flow Manual adjustment factors allow for scheduling refinement by station hole program or course Calculates and executes runtimes to the minute Low voltage communication over power operations Utilizes latching solenoid with Fail safe Power Off protection mode Automated adjustment factors allow scheduling refinement from 0 900 Optional weather station and pump station alarms Up to 99 responses for any alarm Integration with Toro Turf Guard Soil Sensor system Pump Station monitoring with Flowtronex Pace Pump Station Flowtronex Pumplog software Watertronics WaterVision software Grundfos Pump Station with Toro Grundfos Integration Service softwa
6. Stations that have not operated as scheduled shall be identified with a graphic red Water Drop The Course Report Alert Panel shall display feedback from the Gateway s to indicate station status The Course Report will utilize the Area Hole Station layout with Dynamic Drill down to quickly navigate to exceptions The central controller shall support the creation of a customized site map displaying multiple layers The central controller shall allow the user to quickly create a map from any digital image jpeg bmp or tif format The control system will allow the user to edit the locations of sprinklers Turf Guard Sensors and switches on the map The central controller shall provide system status at the station level and display changes in status The central controller shall be capable of creating user defined work orders If a scaled CAD map is utilized the central controller will display area and distance measurements The central controller shall be capable of graphically displaying projected flow on the map at the station level and displaying station activation utilizing a color coding system that shows how stations will activate during the next 24 hours The central controller shall be capable of creating irrigation programs through the map and making station level percentage adjustments When programming or manually running stations the map shall be capable of automatically zooming into the stations holes and areas selected The cen
7. re User definable names versus system defaults On line context sensitive Help screens Advanced reporting capabilities Provides informational displays of the central controller status actual watering times per station contents of the database overview of scheduled irrigation activity Allows for graphical presentation of the system projected flow an analysis of sensor data and water usage by the irrigation system Reports for Water Usage Weather data Pump Station operation with Optional Weather ET and Pump Integration software Hand held radio capability Remote sprinkler activation by area and hole address Remote sprinkler activation by hardware address Runtime Adjustment by percentage Pause and resume Station Test by area and hardware Station activation by decoder serial number Irrigation methods Basic daily run times or application amounts assigned to programs With Weather ET software option Intermediate run times modified automatically with changes in daily ET identified by ET source Advanced run times calculated automatically based on sprinkler data site parameters and measured ET Microsoft Windows 7 Ultimate operating platform True 100 64 bit architecture Supports 16 languages English Bulgarian Simplified Chinese Czech Danish Dutch French German Italian Japanese Korean Norwegian Portuguese Russian Spanish and Swedish Supports U S and metric units of measure Runs on Toro basic computer contact local dist
8. re area or for an individual hole area Manual programs may be started in normal program time or a manually selected time The central controller shall have the ability to start a multi manual cycle on a wire path running up to 100 stations simultaneously with a run time of up to 99 minutes The central controller shall have the ability to independently suspend hold the automatic operation of an individual station or course The station hold duration shall be programmable for the current irrigation day up to 30 days or may be permanent The central controller shall have the ability to control non irrigation devices through switch outputs Each switch up to 50 will have an independent seven day calendar schedule and start times for up to 24 starts Switch outputs may run from one minute to 23 hours and 59 minutes programmable in one minute increments with individual start times for each station switch output Switches may also be scheduled to run with any program and include the ability to offset the start time prior to or after the start of the program The central controller shall allow a user defined response to a Gate Way alarm for pump pressure or rainfall and allow a user defined response to a weather station rainfall threshold The central controller shall offer a Weather ET software option for configuring weather alarms for Rainfall Rain Re Flow alarm response Wind Speed Temperature Wind Direction Solar Radiation Relative Humidity
9. ributor for current specifications Integrated Map software allows Dynamic interactive operation Use of a non scaled graphic image file Use of a scaled CAD generated map Enhanced graphics GPS compatibility for accuracy End User Editing of Sprinkler Sensor and Switch locations Floating of map onto secondary 1080P monitor Standard Weather Software allows On site or off site weather station Rain Shut Down alarm response Optional Weather ET software allows Automatic system adjustment using ET Interactive automatic response to the central User defined alarm thresholds Rain Re Flow alarm responses Standard Pump software allows Monitoring of 1 pump station Optional Pump Integration software allows Pump station integration with 1 pump station and alarm responses Bidding Specifications Central Controller The central controller shall utilize a personal computer based Microsoft Windows 7 Ultimate platform user friendly irrigation management and control program The central controller shall utilize a client server architecture Computer shall include 2 video outputs and allow map graphic to be floated onto secondary monitor The central controller shall utilize site graphics with 64 bit software including site graphics at the station level The software shall be presented in a flat display where all of the information needed is available to the user for a given operation without having to open and close additional windows
10. specified times when integrated with a Flowtronex Pump station equipped with their Pace controls The system shall require a personal computer which has been certified by the manufacturer for use with the central control system The system shall come with a one year dedicated support program provided by the manufacturer which includes extended warranties 24 hour component replacement toll free help line support and remote diagnostics by a licensed irrigator The system shall include NSN Connect for secure remote access to allow the user to operate the Lynx system from any computer connected to the internet This will also allow NSN to do remote diagnostics and support of the central controller The system shall include one year of NSN Connect Plus a service that will allow NSN to remotely monitor the computer 24 7 365 and will alert the user to internal computer hardware and software issues The system shall include one year of Lynx Mobile a service which will allow the user to remotely control Lynx 24 7 365 from any web enabled mobile device This service will provide for manual irrigation communication diagnostics viewing of course status and alerts The central controller shall be developed manufactured qualified and released in the USA by an ISO 9001 certified facility The central controller model number shall be manufactured by The Toro Company Irrigation Division Riverside California USA Note Lynx Electro Flow NSN NSN
11. tral controller shall have the ability to communicate with and control 4 GDC Gateways each with up to 2 Station Groups Wire Paths for a total of up to 500 stations The central controller shall automatically calculate sunrise and sunset based on longitude latitude and date and provide this information for starting or stopping a program in relation to sunrise or sunset The central controller shall permit true random access of all stations in the system and allow area programs to be constructed with any combination of stations regardless of wiring sequences or satellite designation The central controller shall have the ability to manually adjust percentage increase decrease by course area hole or station With Optional Weather ET software module system adjustment factors may be input via actual percentage or operational ET The central controller shall have the ability to connect to a weather station The weather station will measure and store temperature relative humidity dew point wind speed and direction and solar radiation for use in the calculation of evapo transpiration The central shall have the ability to automatically calculate and adjust watering times based on evapo transpiration The central controller shall also have the ability to reduce the automatically calculated runtime by the rainfall measured over the preceding 24 hours Further the central controller shall have the ability to adjust calculated runtimes after they have