Home
Therma-Stor Products Group 3000R User's Manual
Contents
1. c Press and hold the WENT button until CLOSED flashes on the display DEH 3000R Dehumidifier amp Ventilation System Controller Turn the DEH 3000R ON by pressing the ON OFF button d Release the WENT button then press it again to switch vent mode to OPEN e Confirm that the Ultra Aire fan is ON Ventilation damper is OPEN Ultra Aire compressor must be OFF f Press and hold the WENT button until the OPEN flashes on the display g Release the WENT button then press it again to switch vent mode to CLOSED A WARNING DO NOT MAKE ANY OTHER CONNECTIONS OR TRANSFORMER DAMAGE MAY RESULT 7 Verify any additional optional control operations such as fan interlock or A C lockout 8 Proceed to the Operation section 2 6 Troubleshooting FOR THE HVAC PROFESSIONAL No display on initial start up Note This is often the result of a drained capacitor The capacitor will recharge once power is applied or re applied to the unit Verify unit has power Turn unit off then on Disconnect the unit from power source then re apply power to the unit Display should now operate E Function not working properly Verify wiring Verify voltage with voltmeter Dehumidifier not working properly See chart below Wire connections Yellow amp Blue Yellow amp Green Operation Fan amp Compressor Fan Only Installation Operation amp
2. PROGRAM MON FRI DAY START DENT OPEN FOR 15 CLOSED FOR 15 8 00AM 1 Enter the starting time for weekdays using the up down RH buttons to change the time 2 Press the PROGRAM ENTER button to switch to the OPEN FOR setting Using the up down RH buttons change the duration that the damper will ventilate fresh air 3 Press the PROGRAM ENTER button to switch to the CLOSED FOR setting Using the up down RH buttons change the duration that the damper will remain closed between ventilation cycles For the example given starting at 8 00AM in the morning the control will ventilate fresh air for 15 minutes then stop for 15 minutes This schedule of 15 minutes open 15 minutes closed will continue until the start time of the night schedule Morning schedule is available anytime from 12 00AM until 11 59AM Night schedule is available anytime from 12 00PM until 11 59PM 4 Press PROGRAM ENTER again to go to the MON FRI night schedule Repeat the steps listed above for this and the SAT SUN day and night schedules When you have finished programming your schedule either the DEH 3000R Dehumidifier amp Ventilation System Controller 7 day version or the weekday weekend split version use the down RH button to highlight the EXIT option and then press PROGRAM ENTER to select it Running the Ventilation Program Press and hold the PROGRAM ENTER b
3. Service Manual FOR INSTALLER amp HOMEOWNER 3 Operation On the display screen a solid O in front of any of the 3 functions SETPOINT VENT FAN indicates the function is operating A flashing 0 indicates it is in a wait mode and not available at the moment No 0 indicates the function is currently OFF Solid O before Indicates SETPOINT Dehumidifier on VENT Fresh air ventilation cycle in progress FAN Fan on Wait mode is a factory programmed time period meant to prevent short cycles This extends the life of the dehumidifier When a flashing 0 is encountered the unit is in wait mode and IT COULD BE UP TO 10 MINUTES BEFORE OPERATION RESUMES 3 1 Display e Whenever there is power to the control it will display the time the day relative humidity and temperature e When the control is actually switched ON the RH setpoint fan status run mode program or hold and fresh air ventilation status is displayed 12 60AM MONDAY 0 l5 O SETPOINT 50 o DENT CLOSED o FAN AUTO HOLD e When a key is pressed the display will light for approximately v2 a minute e The Time and Day is displayed at the top of the screen e RH and Temperature are displayed in real time e A solid 0 before the SET POINT VENT OR FAN indicates the function is operating e A flashing 0 before the SET POINT VENT OR FAN indicates the unit is in wait mode 3 2 Setting During the set up proc
4. INSTALLER S amp OWNER S MANUAL HVAC INSTALLER PLEASE LEAVE MANUAL FOR HOMEOWNER Al Ultra Aire DEH 3000R b s a E ae Fe a Part No 4028407 Dehumidifier amp Ventilation System Controller h Therma Stor uc Driven by performance Powered by design P O Box 8680 Madison WI 53708 e TOLL FREE 1 800 533 7533 e www thermastor com e sales thermastor com 2008 Therma Stor LLC e Manual P N TS 506b Table of Contents 1 Contents amp Specifications c cc ccccsesesseesssseeseesseeeees 2 2s NIVEL EIEE ass eee ga gprs cei EEE tec weve ee ates EEE 2 2 1 Install Instructions tex isdstrosesacauisoenconeccessaseeceeeeenetcoat 2 A 2 NV e 3 2 3 Auxiliary Relay A C Lockout or Run Central Fan 3 2 4 Dehumidifier Activate De Activate with A C Unit 4 PSO UNO eee epaecan eel anauieace sas esetaeastrpeetaantoanaeee 5 2 6 TTOUDIESNOOTING cccccceccesessecssseesesseeesseeeeseeeeesenes 5 EROE ULE EEE E E A AT O ere 5 Si MOIS DIAY een E 6 S OU ING e ete eee 6 3 3 Personal Settings reference 6 3 4 On Off and Display items 6 3 0 S6tiNG Glock TIME os ctessacectancsce parseracesrctasistehamenaaayes 6 3 6 Adjusting the Relative Humidity Setpoint 0 000 6 3 7 Fan Setting amp Operation oeenn 7 3 8 Damper Operation and Ventilation Manual Hold MOO ies ssinncssecisxesctnasctasivastencucttaaiaviieeneiecneads 8 3 9 Damper Operation and Ventilation Programmed Ventilati
5. Operation amp Service Manual 5 Press the CLOCK button again and the day display will flash Use the RH buttons to change the value 6 Don t touch any buttons for several seconds until the display Stops flashing this will save your settings If you need to change anything go back to step 1 3 6 Adjusting the relative humidity SETPOINT The DEH 3000R senses the ambient relative humidity RH of the space in which it is located it comes factory preset to hold 50 relative humidity The relative humidity SETPOINT desired RH to be maintained operates the dehumidifier function of the Ultra Aire dehumidifier It has no effect on the optional VENT fresh air ventilation or FAN household air recirculation functions if they are being used Operation The standard range that the dehumidifier holds around your SETPOINT is 3 With a setpoint of 50 the dehumidifier will run until the relative humidity reaches 47 The dehumidifier will then switch off until the relative humidity reaches 53 Ambient RH 12 00AM MONDAY 41 9 SETPOINT 50 DENT CLOSED OFAN AUTO HOLD Current Setpoint lf the setpoint is higher than the ambient relative humidity the space does not need to be dehumidified so the dehumidifier will not run Example Setpoint 50 RH Current condition 45 RH The dehumidifier will be off no 0 indicator will be displayed lf your setpoint is below the ambient co
6. THE DESIGN SALE INSTALLATION USE REPAIR REPLACEMENT OR PERFORMANCE OF ANY PRODUCT COMPONENT PART THEREOF OR WRITTEN MATERIAL PROVIDED THEREWITH BE LIABLE TO THE EXTENT ALLOWED UNDER APPLICABLE LAW UNDER ANY LEGAL THEORY FOR ANY SPECIAL DIRECT INDIRECT COLLATERAL OR CONSEQUENTIAL DAMAGES OF ANY KIND NOTWITHSTANDING THE ABOVE LIMITATIONS AND WARRANTIES THE SOLE AND EXCLUSIVE LIABILITY OF THERMA STOR REGARDLESS OF THE NATURE OR THEORY OF THE CLAIM SHALL UNDER NO CIRCUMSTANCES EXCEED THE PURCHASE PRICE OF THE PRODUCT COMPONENT OR PART UPON WHICH THE CLAIM IS PREMISED Applicable Law and Venue ANY ARBITRATION ENFORCEMENT OF AN ARBITRATION OR LITIGATION RELATED TO THE PRODUCT WILL BE BROUGHT EXCLUSIVELY IN DANE COUNTY WISCONSIN AND CUSTOMER CONSENTS TO THE JURISDICTION OF THE FEDERAL AND STATE COURTS LOCATED THEREIN SUBMITS TO THE JURISDICTION THEREOF AND WAIVES THE RIGHT TO CHANGE VENUE CUSTOMER FURTHER CONSENTS TO THE EXERCISE OF PERSONAL JURISDICTION BY ANY SUCH COURT WITH RESPECT TO ANY SUCH PROCEEDING Miscellaneous If any term or condition of this Limited Warranty is found by a court of competent jurisdiction to be invalid illegal or otherwise unenforceable the same shall not affect the other terms or conditions hereof or thereof or the whole of this Limited Warranty Any delay or failure by Therma Stor to exercise any right or remedy will not constitute a waiver of Therma Stor to thereafter enforce such rights I
7. ULTRA AIRE Call for Heat White Wor W1 DEHUMIDIFIER BEFORE WIRING THE DEH 3000R Force Fan On Green G The installer must supply all field wiring including the Compressor wiring between the Ultra Aire dehumidifier and the DEH Call for Cooling Yellow YorY1 3000R Some of the control wires leaving the Ultra Aire may 7 not be used in some control situations and should be left 2 3 Auxiliary relay operation disconnected with wire nuts taped onto the stripped ends It may be desirable to coordinate fan operation of the central heating cooling system with dehumidifier operation The DEH Be sure to consult the electrical schematic in this manual or 3000R contains a relay that provides this ability the internal electrical box of the Ultra Aire dehumidifier before making any control connections mls gt Phare Ultra Aire Dehumidifier White 5 cc 5 amp S 5 8 8 al COM NC Y O The relay terminals labeled NC COM and NO operate according a DEH 3000 Wiring Diagram to the following chart DEHUMIDIFIER COM to NO COM to NC a cone BM ON CONNECTED OPEN OFF OPEN CONNECTED Common uses assuming standard thermostat wiring colors as A WARNING ONLY CONNECT THE WHITE WIRE noted TO THE CONTROL IF IT IS WIRED IN A CIRCUIT THROUGH AN ELECTRIC DAMPER OTHERWISE TRANSFORMER DAMAGE MAY RESULT Lock out the A C during dehumidification This will turn off the A C whenever the dehumidifier runs 1 Wire the Yellow t
8. ading 2 Another Yellow wire must be added to the thermostat Yellow terminal and run to the OFF DET sensor terminal on the DEH 3000R DEHUMIDIFIER YELLOW AIR CONDITIONER TRANSFORMER TO A C Deactivate dehumidification when the air conditioner is running A voltmeter is required for the next steps to ensure the correct wiring from the A C transformer is used to set up the Lock out dehumidifier function 1 The common wire from the existing A C transformer usually Black must be attached to the Yellow wire from the Ultra Aire dehumidifier TIP The common wire can be identified as the wire from the A C transformer that reads 0 volts between it and the Yellow air conditioning call for cooling wire The incorrect wire will give a 20 to 28 volt reading 2 Another Yellow wire must be added to the thermostat Yellow terminal and run to the ON DET sensor terminal on the DEH 3000R DEHUMIDIFIER Installation Operation amp Service Manual 2 5 Testing Verify the wiring connections A WARNING ONLY CONNECT THE WHITE WIRE TO THE CONTROL IF IT IS WIRED IN A CIRCUIT THROUGH AN ELECTRIC DAMPER OTHERWISE TRANSFORMER DAMAGE MAY RESULT After checking the wiring this short test will confirm proper hook up 1 Install front cover of the DEH 3000R connect the top first then the bottom 2 Plug in the Ultra Aire dehumidifier The DEH 3000R should power up A cd Verify dehumidification operation b
9. ess if you make a mistake simply continue You can always go back to adjust the settings If you leave the control alone and don t touch any buttons for 10 DEH 3000R Dehumidifier amp Ventilation System Controller seconds the control will remember any changes made and return to the normal display screen allowing you to proceed to the next step 3 3 Personal Settings reference list Please record your settings here Function Factory setting My Setting SETPOINT RH 50 VENT Closed FAN Auto TEMP CUTOUT 99 3 4 On Off and display items Press the ON OFF button to turn the system ON or OFF When the system is ON the setpoint fan status operation mode RUN or HOLD and fresh air vent status is displayed DEH 3000 Switched ON 12 80 AM MONDAY 30 l5 O SETPOINT 50 o VENT CLOSED OFAN AUTO HOLD When the system is OFF the control will display the time day RH and temperature When the unit is shipped it is in manual hold mode DEH 3000 Switched OFF 12 00AM MONDAY 0 Jon 3 5 Setting Clock Time 1 Press and hold the CLOCK button The hour display will flash Release the button 2 Use the up down RH buttons to change the value 3 Press the CLOCK button again and the minute display will flash Use the RH buttons to change the value 4 Press the CLOCK button again and AM or PM will flash Use the RH buttons to change the value Installation
10. he ON and AUTO modes 12 00 AM MONDAY 30 l5 SETPOINT 50 DENT CLOSED o FAN AUTO HOLD Fan Mode AUTO ON With the fan in the AUTO mode the fan will operate only when needed by other functions of the system The fan will remain OFF unless the system is dehumidifying or ventilating The fan always runs during dehumidification and ventilation and the fan 0 icon will be lit To completely turn the system OFF use the ON OFF button as described earlier Installation Operation amp Service Manual 3 8 Damper Operation and Ventilation Manual Hold Mode The WENT setting controls the ventilation function of the system It has no control over the dehumidification function In order to provide ventilation the motorized damper must be open and the fan must be running The controller takes care of these two functions automatically so that whenever the damper is open the fan is running The ventilation indicator 0 will be displayed whenever the unit is ventilating The fan operation indicator 0 will also be lit There are three damper operation modes 1 OPEN hold mode The damper will be open and the dehumidifier fan will be continuously operating to introduce fresh air into the space Use this mode for continuous fresh air ventilation The fan is always on when the damper is open 2 CLOSED hold mode The damper will never open and the dehumidifier wil
11. he terminals on the back panel as shown in the applicable wiring diagram see Sections 2 2 2 4 5 Test the installation see Section 2 5 Mounting Hole l ae cw fen TELLG 3 gt Bi eI Edda L a CT EA R S a rae lie WO 05 o op Mounting Hole 24 VAC Yellow Wire 24 VAC Red Wire Normally ON Open DET Optional_ Common Optional Ise OFF Use Normally DET Closed Damper Dehumidifier Fan White Wire Blue Wire Green Wire Optional See warning below Installation Operation amp Service Manual 2 2 Wiring The White wire controls the optional motorized damper that can be installed into a fresh air duct This damper A WARNING DO NOT ALLOW THE YELLOW provides the ability to control fresh air ventilation using WIRE FROM THE ULTRA AIRE DEHUMIDIFIER TO CONTACT the ventilation timer function of the DEH 3000R and THE RED OR WHITE WIRES FROM THE ULTRA AIRE the terminal labeled DMP on the DEH 3000R See DEHUMIDIFIER DAMAGE TO THE 24 VOLT TRANSFORMER Section 3 8 Leave the DMP terminal unused if a WILL RESULT motorized damper is not used and cap off the White wire from the Ultra Aire dehumidifier A WARNING THE REMOTE CONTROL OF THE ULTRA AIRE DEHUMIDIFIER OPERATES ON A LOW VOLTAGE Standard wire colors for thermostats are as follows CIRCUIT 24 VAC AND MUST NEVER CONTACT OR BE Description Color Terminal code CONNECTED TO A HIGH VOLTAGE CIRCUIT aaas oas a 24VAC Red R A WARNING UNPLUG THE
12. hermostat terminal to the NC terminal on the DEH 3000R DEH 3000R Dehumidifier amp Ventilation System Controller 3 Installation Operation amp Service Manual 2 Run the Yellow wire from the A C unit to the COM terminal on the DEH 3000R Energize the A C central fan during dehumidification To automatically run the A C FAN when the dehumidifier runs 1 Attach a second Green wire to the Green fan wire terminal on the thermostat 2 Connect the new Green wire to the COM terminal on the DEH 3000R 3 Runa wire from the Red terminal on the thermostat to the NO Normally Open terminal on the DEH 3000R Green Yellow 2 4 Dehumidifier lock OFF or lock ON A C sensor feature To automatically activate or deactivate the dehumidifier when the air conditioner runs 24 VAC Yellow wire from dehumidifier Activate dehumidification when the air conditioner is running A voltmeter is required for the next steps to ensure the correct DEH 3000R Dehumidifier amp Ventilation System Controller wiring from the A C transformer is used to set up the Lock in dehumidifier function 1 The common wire from the existing A C transformer usually Black must be attached to the Yellow wire from the Ultra Aire dehumidifier TIP The common wire can be identified as the wire from the A C transformer that reads 0 volts between it and the Yellow air conditioning call for cooling wire The incorrect wire will give a 20 to 28 volt re
13. ing the ventilation timer There are two programs available for ventilation 1 Monday through Sunday 2 Monday through Friday amp Saturday Sunday Each block of days has a morning schedule and a night schedule Morning is the first 12 hours of the day and night is the second 12 hours Each schedule has e A START time when the ventilation schedule begins e An OPEN FOR duration for the amount of time the damper stays open in 5 minute intervals from 0 to 60 e And CLOSED FOR duration which closes the damper for a specified time in 5 minute intervals from 0 to 60 Setting the Ventilation Program 1 Press the PROGRAM ENTER button until the following menu appears PROGRAM HOLD RUN PROGRAM PROGRAM TEMP CUTOUT ERIT 2 Using the up down RH buttons highlight PROGRAM and select it by pressing the PROGRAM ENTER button The following menu appears Installation Operation amp Service Manual PROGRAM MON FRI SAT SUN MON SUN ERIT You can select from MON FRI SAT SUN for separate weekday and weekend schedules or MON SUN which gives you equal weekday and weekend schedules 3 Using the Up Down RH buttons highlight and then select one of the two choices The example given shows how to program separate weekday and weekend schedules The same method is used if you choose the other program Example menu when you select MON FRI SAT SUN
14. isclaimer of Warranties EXCEPT FOR ABOVE LIMITED WARRANTY WHICH IS THE SOLE AND EXCLUSIVE WARRANTY PROVIDED WITH RESPECT TO THE PRODUCT AND ITS COMPONENTS THERMA STOR HEREBY DISCLAIMS ALL EXPRESS AND IMPLIED WARRANTIES INCLUDING WITHOUT LIMITATION THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE Warranty Limitations The foregoing limited warranty extends only to a Customer and shall be null and void upon attempted assignment or transfer A defect under the terms of the limited warranty shall not include problems resulting from Customer s or Customer s employees agents invitees or a third party s misuse improper installation improper design of any system in which the Product is included abuse lack of normal care failure to follow written instructions tampering improper repair or freezing corrosion acts of nature or other causes not arising out of defects in Therma Stor s workmanship or material If a Product or Component is replaced while under warranty the applicable limited warranty period shall not be extended beyond the original warranty time period The limited warranty does not cover any costs related to changes to a Product or Component that may be required by any codes laws or regulations that may become effective after initial purchase of the Product by Customer DEH 3000R Dehumidifier amp Ventilation System Controller 11 Dehumidifier amp Ventilation System C
15. l not ventilate The fan will still operate normally for recirculation and dehumidification 3 PROGRAMMED mode The DEH 3000R will operate the motorized damper and the dehumidifier fan according to the programmed ventilation schedule Section 3 9 The factory preset for the VENT setting is CLOSED To set OPEN hold or CLOSED hold ventilation operation 1 Press the WENT button The current setting will begin to flash on the display Release the button 2 Press the WENT button again to switch between OPEN and CLOSED 3 Leave the control alone for 10 seconds and your settings will be saved 12 00AM MONDAY gg 15 gg 15 SETPOINT 58 SETPOINT 58 DENT OPEN DENT CLOSED FAN AUTO HOLD FAN AUTO HOLD 12 00AM MONDAY 3 9 Damper Operation and Ventilation Programmed Ventilation This example shows the system in program mode denoted by the schedule 15 minutes on 5 minutes off and the word RUN in the lower right corner of the display DEH 3000R Dehumidifier amp Ventilation System Controller 12 30 AM MONDAY 0 l3 SETPOINT 50 15 05 o VENT a FAN AUTO RUN The status of the damper is show here O is open blank is closed The DEH 3000R will operate fresh air ventilation according to your ventilation program The control needs to be programmed to turn the ventilation function ON and OFF at the desired intervals This is done by programm
16. ndition the dehumidifier will be on and 0 will display Example Setpoint 50 RH Current condition 55 RH The dehumidifier will be on 0 displayed DEH 3000R Dehumidifier amp Ventilation System Controller 3 Fan Setting and Operation Use the FAN button to change the fan operation There are 2 choices for fan operation ON or AUTO The factory preset is AUTO ON The fan in the Ultra Aire dehumidifier will run continuously This does not affect either the dehumidification or ventilation functions of the system The system may or may not be ventilating or dehumidifying while the fan is running This setting is commonly used for maximum air filtration and or air recirculation AUTO Indicates the fan will run when the DEH 3000R calls for dehumidification or ventilation If the control has not called for dehumidification for 3 hours the control will automatically run the dehumidifier fan for 10 minutes After a dehumidification cycle the fan automatically shuts off for 10 minutes This pause allows the water to drain from the dehumidifier A solid 0 indicates the fan is operating A flashing 0 indicates the fan is in a wait mode No 0 indicates the fan is OFF To set the operation 1 Press and hold the FAN button The current fan setting will begin to flash on the display Release the button 2 Press the FAN button to toggle between t
17. nstallation Operation amp Service Manual Thermea Stor c Driven by performance Powered by design Information in this document is subject to change without notice No part of PO Box 8680 e Madison WI 53708 this document may be reproduced or transmitted in any form or by any means Phone 608 222 5301 Fax 608 222 1447 electronic or mechanical for any purpose without the express written permission www thermastor com sales thermastor com of Therma Stor LLC 2007 Therma Stor LLC All rights reserved Installation Operation amp Service Manual DEH 3000R Dehumidifier amp Ventilation System Controller
18. of initial purchase of such Product by an original customer purchasing from Therma Stor or an authorized reseller Customer and ii the Product s condenser evaporator and compressor will be free of material defects in workmanship or materials for a period of five 5 years following the date of initial purchase of such Product by a Customer Limitation of Remedies CUSTOMER S SOLE AND EXCLUSIVE REMEDY UNDER THE ABOVE LIMITED WARRANTY AND THERMA STOR S ENTIRE LIABILITY THEREUNDER SHALL BE AT THE SOLE OPTION OF THERMA STOR REPLACEMENT OR REPAIR OF SUCH PRODUCT OR ITS COMPONENTS COMPONENTS BY THERMA STOR OR THERMA STOR S AGENTS ONLY REFRIGERANT PIPING SUPPLIES TRANSPORTATION COSTS LABOR COSTS INCURRED IN REPAIR OR REPLACEMENT OF SUCH COMPONENTS ARE NOT INCLUDED THIS DISCLAIMER AND EXCLUSION SHALL APPLY EVEN IF THE EXPRESS WARRANTY AND LIMITED REMEDY SET FORTH HEREIN FAILS OF ITS ESSENTIAL PURPOSE CUSTOMER ACKNOWLEDGES THAT NO REPRESENTATIVE OF THERMA STOR OR OF ITS AFFILIATES OR RESELLERS IS AUTHORIZED TO MAKE ANY REPRESENTATION OR WARRANTY ON BEHALF OF THERMA STOR OR ANY OF ITS AFFILIATES OR RESELLERS THAT IS NOT IN THIS AGREEMENT Notwithstanding the above during the term of the One Year Warranty only Therma Stor will provide free of charge to Customer all Components and labor except costs related to removal and installation of Product required to fulfill its obligations under such One Year Warranty D
19. on ccccceccscesssessssetesseesseeess 8 4 0 Temperature Cutout Programming cccccccseeeeeees 9 O DER OOO ra 10 Wanay aeiiae esa EEEE 11 Read and Save These instructions WARNING This symbol means important instructions Failure to heed them can result in serious injury or death 1 Specifications Part P N 4028w407 Model DEH 3000R Operating Voltage 24 VAC Max Current DMP COMP FAN 1 AMP each Humidity Range Accuracy 10 95 RH 5 Auxillary Relay Capacity 5 Amps 24VAC Temp Range Accuracy 30 90 F 2 Size 4 95 L x 1 06 W x 4 19 H 2 Installation Install the DEH 3000R control panel in a central area of the structure where it will sense the relative humidity of the structure accurately Do not install the control panel where it may not accurately sense the relative humidity such as near HVAC supply registers near exterior doors and windows or near a pool or spa Install in accordance with all applicable codes and standards DEH 3000R Dehumidifier amp Ventilation System Controller 2 1 Install Instructions 1 Separate the front panel from the back panel by depressing the middle sections of the top and bottom of the front panel 2 Locate the wiring access hole in the wall or other flat mounting surface Place the back panel into position and drill the appropriate mounting holes 3 Insert the screws and tighten Level as necessary 4 Make the electrical connections to t
20. ontroller Customer Responsibilities As a further condition to obtaining warranty coverage hereunder the Customer must send a valid warranty claim to Therma Stor such that Therma Stor receives such claim prior to the end of the applicable warranty period Therma Stor shall have no obligation hereunder with respect to any claim received by Therma Stor after the expiration of the applicable warranty period As a further condition to obtaining warranty coverage hereunder the Customer must present forms of invoices evidencing proof of purchase of a Product If such invoices do not clearly indicate the date of initial purchase by a Customer the applicable Product s date of manufacture will be used instead of the date of initial purchase for the purpose of calculating the commencement of the applicable warranty period Warranty service must be performed by Therma Stor or a servicer authorized by Therma Stor In order to obtain warranty service the Customer should call Therma Stor at 1 800 533 7533 and ask for the Therma Stor Products Service Department which will then arrange for applicable warranty service Warranty service will be performed during customary daytime working hours If the Product must be shipped for service Customer shall be solely responsible for properly packaging the Product for all freight charges and for all risk of loss associated with shipment Limitation of Liability IN NO EVENT SHALL THERMA STOR IN CONNECTION WITH
21. standard DEH 3000 controller does not offer remote functionality Remote Sensor alfa ALL i d an a a Uitr aAl re 5 1 Remote Sensor Usage A IMPORTANT e The use of spray paint on the sensor housing may damage the sensor and is not covered by the product warranty The remote sensing option is used when an installation requires mounting the DEH 3000R out of the conditioned space or when it is desired to specifically monitor and control the conditions at a particular location in a larger conditioned space Both the need for and location of the remote sensor should be determined by a heating cooling professional In most installations the onboard sensor in the DEH 3000R will be sufficient to monitor and control the conditioned space 5 2 Install and Wiring Instructions 1 Routing signal wires You will be required to supply and route 24 gauge 4 conductor solid wire 2 line telephone wire between the DEH 3000R controller and the remote sensor location The wiring run should be no longer than 100 ft Avoid routing this interconnect wire parallel to high voltage wiring Maintain a distance of 2 ft or more from high voltage lines e Do not run wires longer than 100 ft e The use of 24 gauge wire is optimal Thinner gauge wire may DEH 3000R Dehumidifier amp Ventilation System Controller x8 Splice Connectors Ta i Less than 100 ft a P limit sensor distance Thicker gauges will not work
22. utton until the PROGRAM screen appears Use the down RH button to highlight RUN PROGRAM PROGRAM HOLD RUN PROGRAM PROGRAM TEMP CUTOUT ERIT Then press PROGRAM ENTER to select it The display will appear as follows 12 00AM MONDAY 30 l3 SETPOINT 50 o VENT 15 15 o FAN AUTO RUN Vent schedule on time off time Program RUN mode 4 0 Temperature Cutout Programming Dehumidifiers produce heat when dehumidifying and depending upon outside conditions the ventilation function may also introduce warm air Some conditions may introduce enough heat to drive household temperatures up The DEH 3000R temperature cutout feature disables all Ultra Aire operations if household temperatures reach the cutout setpoint In most installations this feature will not need to be used the cutout is factory set to 99 F If a lower temperature cutout is desired program the setpoint by pressing and holding the PROGRAM ENTER button until the PROGRAM screen appears Press the up down RH buttons until TEMP CUTOUT highlighted Then press the PROGRAM ENTER button again to select it Now use the RH up or RH down buttons to adjust the setpoint Press PROGRAM ENTER to return to the home screen Installation Operation amp Service Manual 5 0 DEH3000R Remote sensor option This section is applicable only to customers who have purchased a remote sensor package The
23. with splice connectors provided e Avoid routing parallel to high voltage wiring e Maintain a distance of 2 ft or more from high voltage lines 2 Sensor connection The sensor can be mounted to a wall or ceiling surface Ideal sensor location is 5 ft above the floor Wires should exit through a 12 diameter hole in the mounting surface at the mounting location Use the provided splice connectors to connect the 4 wires from the remote sensor to the user supplied interconnect wire Be sure to keep proper colors attached to each other 3 sensor mounting Peel the backing from the self adhesive tape on sensor housing and stick in place Apply pressure to insure permanent placement e When installing the sensor use the up marking when placing the sensor on a vertical wall This will help keep your sensor clean and free of dust 4 Controller connection Use the provided splice connectors to connect the 4 wires from the DEH 3000R to the user supplied interconnect wire Be sure to keep the proper colors attached to each other Continue with the installation as described in the rest of this manual 10 Installation Operation amp Service Manual wi Ultra Aire DEH 3000R Limited Warranty Therma Stor LLC Therma Stor warrants as follows i the DEH 3000R Product will be free of material defects in workmanship or materials for a period of three 1 year One Year Warranty following the date
24. y adjusting the RH SETPOINT to below the RH reading on the display Use the down RH button Confirm Ultra Aire fan and compressor operation Both should be ON now Increase the RH SETPOINT on the display to well above the ARH reading on the display Press the RH up arrow to increase the RH SETPOINT After running the dehumidifier compressor the DEH 3000R applies a 10 minute restart lockout on all functions You will have to wait for the restart lockout to expire 5 Verify FAN only operation a Check the WENT mode on the display it will either be CLOSED or OPEN If it is CLOSED go to the next step If it is OPEN press and hold the VENT key until OPEN flashes on the display release the key and then press it one more time OPEN will change to CLOSED Don t touch the keys for several seconds until it stops flashing b Press and hold the FAN button until AUTO begins flashing on the display release it and then press it again to switch the fan to the ON setting c Confirm that the Ultra Aire fan is ON Ultra Aire compressor must be OFF Ventilation damper if used should be CLOSED 6 Verify optional VENT operation if electric damper is installed a Press and hold the FAN button until ON flashes on the display b Release the FAN button then press it again to switch fan operation to AUTO
Download Pdf Manuals
Related Search
Related Contents
ASCO Quality Care Symposium Exhibitor Manual Euroset 5030 - Aggiungi a preferiti M. O. CG PT Audiovox D1708PK User's Manual Philips X-tremeVision DMP40, DMP40S2 Betriebsanleitung AFS Massive Top Selection Spot light 53143/31/10 HP rp8440 Getting Started Guide ASUS (M81C) User's Manual Copyright © All rights reserved.