Home
Therma-Stor Products Group TS-261B User's Manual
Contents
1. located in close proximity to the top of the cabinet near the corners A lock nut should be visible through each of the mounting holes and is held in place by a retainer plate secured to the cabinet shell Verify lock nut is visible in each mounting hole Figure 2 Mounting holes 3 Place a socket head cap screw M10 x 35mm into each of the holes in the handle end brackets Position the handle assembly up against the Phoenix Mini Guardian HEPA System cabinet so as to align the cap screws with the mounting holes in the cabinet It may be necessary to tilt the handle assembly up ata slight angle in order to align the screws with the lock nuts Use the 8mm hex key to press the cap screws into the mounting holes and engage the threads of the lock nuts Figure 3 Handle tilting for assembly Toll Free 1 800 533 7533 4 Tighten each of cap screws using the 8mm hex key until the handle assembly is secured against the cabinet surface and all space between parts is eliminated Figure 4 Tightening screws 2 2 Transporting the Phoenix The Phoenix Mini Guardian HEPA System should be upright when transported by vehicle It may be tipped on to its back for loading and moving by hand or for use on location 2 3 Location CAUTION Note the following precautions when locating the Phoenix Mini Guardian HEPA System It is designed to be used INDOORS ONLY If used in a wet area plug it into a GROUND FAULT INTERRUPTER DO NOT
2. space at half the rate The operator must judge if that is acceptable If the operator determines the filters should be changed due to low airflow it is most economical to change them in the following order Change the pad pre filter top first This is the least expensive filter Recheck the airflow If the airflow is acceptable no other filters need to be changed Change the pleated fabric filter middle second It is the second least expensive filter Recheck the airflow If acceptable the HEPA filter does not need changing If the airflow is still too low the HEPA filter must be changed To remove the HEPA filter follow these steps 1 Loosen the two 3 8 thumbscrews that secure the 4 Lift the old filter straight up and out of the cabinet HEPA filter Place the new HEPA filter with the open side down iw er into the cabinet Be sure the four bumpers on the ra ee l a base center it Figure 10 Disengage screw and spacer ay fA ti k i i on i Figure 8 Loosen thumb screws 2 Push down on the filter hold down bar and out on the back of the cabinet to disengage the two ears from the back of the cabinet Rock the filter hold down bar up towards the front of the cabinet Figure 11 Lift filter straight up Figure 9 Push down on the filter hold down bar Toll Free 1 800 533 7533 6 www thermastor com sales thermastor com 4 Service CAUTION CAUTION Servicing the Phoenix Mini Guardia
3. use the Phoenix Mini Guardian HEPA System as a bench or table The air inlet on top amp the side outlets should be at least 1 foot from walls and other obstructions to airflow 2 4 Electrical Requirements The Phoenix Mini Guardian HEPA System can be plugged into a grounded 15 Amp circuit It draws about 2 Amps with clean filters and no ducting The amp draw will decrease slightly with added ducting and as the filters load with particulate If an extension cord is required it must have a minimum of 18 gauge conductors if 25 feet long or less and 16 gauge conductors if greater than 25 feet long www thermastor com sales thermastor com 2 5 Air Ducting 2 5A Inlet Ducting Occasionally the area to be filtered is difficult to access and or the unit cannot be located in the area In such cases the air can be ducted to the unit s inlet A round 12 diameter flexible duct can be attached to the unit inlet on top It connects by placing the wire in the duct under the four tabs on the top It may be removed after use for easier transport and storage Flexible 12 duct is available from Therma Stor LLC Figure 5 Inlet ducting 2 5B Outlet Ducting A detachable rectangular exhaust collar is supplied that will allow 10 round lay flat plastic duct to be attached to the Phoenix Mini Guardian HEPA System outlet Lay flat plastic ducting is available from Therma Stor LLC To attach ducting to a collar remove the collar fro
4. 7 Efficient Axle Impeller Fan Impeller Fan Speed Control Impeller Fan Speed Control Knob Bumper 59 Dia X 35 High Bumper 1 13 Dia x 1 High Cord amp Wire Harness Foot Handle Assembly Hour Meter Pocket Handle Run Capacitor 20 mfd 370 VAC Outlet Cover Side Outlet Duct Collar Outlet Cover Guard Rear Thumb Screw 1 4 Thumb Screw 3 8 Wheel 5 Plastic Wheel Center Cap Bee i Optional Parts 4021950 4024879 4024891 4024528 4024750 4022537 4024440 eee ee fit GaN e Ace ER A N ut www thermastor com Ground Fault Interrupter Air Filter Disposable Carbon Potassium Permanganate Air Filter Refillable Carbon Potassium Permanganate Carbon Potassium Permanganate 5 gal Pail Duct Flex 12 x 25 Duct Lay Flat 10 x 500 Kestrel 3000 Weather Meter ait eee Specifications subject to change without notice sales thermastor com This page intentionally left blank Toll Free 1 800 533 7533 10 www thermastor com sales thermastor com SS U Oo _ gt D 9 T m gt 7 lt or D 3 m 3 or D Q arranty y Warrantor Y Therma Stor LLC AA PO Box 8680 SSN AZN Madison WI 53708 Telephone 1 800 533 7533 Who Is Covered This warranty extends only to the original end user of the Mini Guardian HEPA f System and may not be assigned or transferred Woods First Year Warra
5. A Therma Stor uc Phoenix Mini Guardian HEPA System TS 261B PO Box 8680 Madison WI 53708 Owner s Manual Phoenix Mini Guardian HEPA System Installation Operation amp Service Instructions Read and Save These Instructions The Phoenix Mini Guardian HEPA System is the compact variable air speed version of our popular Phoenix Guardian HEPA System Maximum delivered air flow with 3 stage filtering in place is over 415 CFM and will clean one air change of a 14 x 14 foot room in less than four minutes while drawing less than two amps of power This makes the Mini Guardian HEPA System perfect for smaller remediation projects where space is at a premium and reduced air flow essential A template on the intake grill makes it possible to take air flow measurements with the Phoenix Kestrel 3000 Multi Meter The Mini Guardian HEPA System s 3 stage filter design with true HEPA filtration will remove virtually all hazardous particles from the air and an optional fourth stage filter of activated carbon and potassium permanganate will absorb a wide range of odors and gases The unique 24 canister HEPA manufactured for the Phoenix Mini Guardian HEPA System contains nearly 200 square feet of surface area This allows maximum air flow and significantly extends filter life The Phoenix Mini Guardian HEPA System Less than 2 amps Compact design Variable speed flow Multiple ducting options Stainless steel cabinet
6. C 99 97 DOP efficient HEPA filter Actual size is 13 7 8 OD x 24 x 8 7 8 ID This filter should be changed when airflow is reduced or it is contaminated by a previous job 3 1A Activated Carbon Potassium Permanganate Filters Optional gas phase filters are available from Therma Stor They use a blend of activated carbon and potassium permanganate This blend removes the vast majority of contaminants encountered in most filtering applications The activated carbon removes the heavier volatile organics while the potassium permanganate removes lower molecular weight contaminants This is well suited to the smoke odors present after fire damage The life of the media blend depends upon both the hours used and the contamination level Another advantage of the blended media versus activated carbon only is Toll Free 1 800 533 7533 that part of the blend changes color as it loads up with contaminants It starts out black then turns pink then brown and finally white It is best changed when it passes the brown stage and begins to turn white It has lost most of its effectiveness at that point When these filters are installed the pad filter does not need to be installed above them This allows the operator to check the media color through the top grill of the unit without removing the top The filter is the same size as the pleated fabric filter Install it above the pleated fabric filter The pleated fabric filter catches carbon d
7. Optional fourth stage carbon filter Wheeled cart design Specifications subject to change without notice Toll Free 1 800 533 7533 1 E my Mobos Aloe ARDIAN W PERA R x 3 f Pi miam pa i BOTE A Phoenix Mini Guardian HEPA System PN 4024774 Revised 1 07 www thermastor com sales thermastor com Table of Contents 1 Specifications Introduction aes 1 partNe 4024774 1 SSPSCHIICALONS cisecsnetnsetunecanecencimmmiunesauedtneesmeamedancdons 1 Power 110 120 Vac 1 96 amps 215 watts 2 Operation sevicicorivieincicersstcaeisentiaerrnintteninetnasbedaeiin 1 2 1 Handle Assembly Procedure cceeceeeeeeeeees 1 BOWO aoe i ieee EERON oe w 3 stage filter operation 2 2 Transporting the Phoenix Mini Guardian HEPA EIIE f i PREE E E EA P EEE E E E 2 Filters I stage 1 Spun Polyester 16 x 16 23 Locati gt 2 stage 2 Pleated Media 16 x 16 3 Loca en EEE Paara aaia 3 stage 14 dia x 24 Canister HEPA 2 4 Electrical Requirements ccd Rte RE Rte emed Cate weeebe eae me 3 optional 4 stage 2 Carbon and Potassium 2 0 Alr UC MING onc cucanescacmeccestenanuanetsiwenseoanwsteatendeninee 3 Permanganate Zi OA Mlet DUCUNE wssccccicctinsindemrsitanniionawinenebenwe 3 Warranty One Year 100 Parts and Labor 2 5B Outlet Ducting aa eerie ey a ee ees ee ee ere a 3 Dimensions 2 6 Negative Air Ducting ccccceceeeeceeeeaeeeeaees 4 Cabinet w Cart Shipping 2 Power Switch oxcecom
8. ge electrical parts and B expose the dangerous rotating impeller fan 2 8 Hour Meter A digital hour meter is located near the power speed control on the unit front It measures the cumulative time that the unit is turned on to tenths of an hour It stores its total when the unit is unplugged The previous total will be displayed when the unit is next turned on It resets to zero after 99 999 9 hours of operation 3 Maintenance 3 1 Air Filters The standard Phoenix Mini Guardian HEPA System is equipped with three filters that progressively filter out smaller particles An optional activated carbon potassium permanganate filter can be used giving a fourth stage of filter media see Section 3 1A These filters must be checked regularly Operating the unit with dirty filters will reduce the airflow but will do no harm to the unit The unit can be run indefinitely with dirty filters The three standard filters used are listed below as installed in the unit from top to bottom A Polyester media pad pre filter Actual size 15 3 4 x 15 3 4 x 1 thick The white side faces up This filter should be replaced when the airflow is reduced it is visibly dirty or when it is contaminated by a previous job B 25 to 30 efficient per ASHRAE 52 1 1992 MERV 7 pleated fabric filter Actual size is 15 3 4 x 15 3 4 xX 1 3 4 This filter should be changed when airflow is reduced or it is contaminated by a previous job
9. ing a very limited amount of air which does not cause backdrafting In case B the open combustion devices must be thoroughly checked to guarantee that they do not backdraft while the Phoenix Mini Guardian HEPA System is running C Direct the outlet duct from the Mini Guardian HEPA System to the room with the open combustion device s This will positively pressurize the room thus preventing backdrafting As in case B those combustion devices must be checked after the Mini Guardian HEPA System is running to guarantee that they are not backdrafting The duct can be directed outside exhausting a portion of the filtered air The rest of the filtered air is recirculated inside the space Blocking the other supply holes will determine the amount of air that is exhausted By adjusting the blocking plates over the supply openings the quantity exhausted can be adjusted down to no flow 2 7 Power Speed Control The power speed switch is located in the recessed cavity on the unit front When turned on to any speed it powers the impeller fan and hour meter Occasionally the impeller fan may not start on low speed If this occurs rotate the speed control to high speed until the impeller fan starts then adjust it to a lower speed www thermastor com sales thermastor com CAUTION CAUTION Do not remove the top to access the filters with the unit on Removing the top and filters while running can A expose potentially fatal high volta
10. m the unit by sliding the collar upward out of the guide Put the plastic duct end through the collar center Roll the duct end outward so that it over laps the outside of the collar The duct will hook over the collar preventing it from Slipping off fe s in mt Figure 6 Outlet ducting Toll Free 1 800 533 7533 2 6 Negative Air Ducting The Phoenix Mini Guardian HEPA System can be used to filter and exhaust air from a space By exhausting to outside the space the space will be under a slight negative pressure This will help prevent airborne particles from leaving the space since the negative pressure will draw air in through openings in the space s exterior The quantity of air exhausted depends on how the unit is ducted and what speed is used A duct can be directed outside Cover the other exhaust openings to direct all the filtered air outside This would result in up to 400 CFM being exhausted on high speed and an equal amount of fresh air being drawn in CAUTION CAUTION Exhausting too much air from a space with open combustion devices e g furnace fireplace or water heater can cause those devices to backdraft This can contaminate the space with potentially fatal gases In such cases the Phoenix Mini Guardian HEPA System must be used in one of the following three ways A Asa filtering unit only Exhausting no air from the Space and thus causing no negative pressure or backdrafting B Exhaust
11. n HEPA System with its high voltage circuitry presents a health hazard that could result in death serious bodily injury and or property damage Only qualified service people should service this unit 4 1 Warranty A warranty certificate has been enclosed with this unit Read it before any repair is initiated If a warranty repair is required call the factory first at 1 800 533 7533 for warranty claim authorization and technical assistance 4 2 Impeller Fan Replacement CAUTION Occasionally the impeller fan may not start on low speed If this occurs rotate the speed control to high speed until the impeller fan starts then adjust it to low speed Follow the steps below to change the impeller fan 1 Unplug the power cord 2 Remove the top and all air filters 3 Remove the rear electrical guard held inside the unit by four mm machine screws and nuts Figure 12 Remove guard Toll Free 1 800 533 7533 4 Remove the cable clamp holding the impeller fan cable and ground terminals Remove the ground wire from the mounting screw Disconnect the black and brown wires from the run capacitor and cut the blue wire near the wire nut HEREIN eat Figure 13 Remove cable clamp 5 Remove the 1 4 machine screws holding the base to the cabinet Remove the base from the cabinet 6 Remove the four 4 mm machine screws that hold the motor to the lower base Remove the cable clamp that holds the impeller fan cable to
12. nty Therma Stor Products warrants that for one 1 year the Mini Guardian HEPA WUA POON System will operate free from any defects in materials and workmanship or Therma Stor Products Bis E 5 z IRA will at its option repair or replace the defective part s free of any charge PN KSN RH End User Responsibilities Warranty service must be performed by a Servicer authorized by Therma Vay Stor Products If the end user is unable to locate or obtain warranty service from an authorized VEY Servicer he should call Therma Stor Products at the above number and ask for the Therma Stor VES Products Service Department which will then arrange for covered warranty service Warranty service A will be performed during normal working hours The end user must present proof of purchase lease upon request by use of the warranty card or other reasonable and reliable means The end user is responsible for normal care This warranty XW does not cover any defect malfunction etc resulting from misuse abuse lack of normal care corrosion freezing tampering modification unauthorized or improper repair or installation accident Vey acts of nature or any other cause beyond Therma Stor Products reasonable control as Wee Limitations and Exclusions If any Mini Guardian HEPA System part is repaired or replaced the new a part shall be warranted for only the remainder of the original warranty period applicable thereto but all warra
13. nty periods will be extended by the period of time if any that the Mini Guardian HEPA System N is out of service while awaiting covered warranty service J UPON THE EXPIRATION OF THE WRITTEN WARRANTY APPLICABLE TO THE Mini Guardian HEPA System x y OR ANY PART THEREOF ALL OTHER WARRANTIES IMPLIED BY LAW INCLUDING MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SHALL ALSO EXPIRE ALL WARRANTIES MADE BY RA THERMA STOR PRODUCTS ARE SET FORTH HEREIN AND NO CLAIM MAY BE MADE AGAINST THERMA AS STOR PRODUCTS BASED ON ANY ORAL WARRANTY IN NO EVENT SHALL THERMA STOR PRODUCTS AZN IN CONNECTION WITH THE SALE INSTALLATION USE REPAIR OR REPLACEMENT OF ANY Mini h N Guardian HEPA System OR PART THEREOF BE LIABLE UNDER ANY LEGAL THEORY FOR ANY SPECIAL REO INDIRECT OR CONSEQUENTIAL DAMAGES INCLUDING WITHOUT LIMITATION WATER DAMAGE THE ROH END USER SHOULD TAKE PRECAUTIONS AGAINST SAME LOST PROFITS DELAY OR LOSS OF USE 37 OR DAMAGE TO ANY REAL OR PERSONAL PROPERTY Some states do not allow limitations on how long an implied warranty lasts and some do not allow the exclusion or limitation of incidental or consequential damages so one or both of these KX KH ee eA limitations may not apply to you Legal Rights This warranty gives you specific legal rights and you may also have other rights which vary from state to state Toll Free 1 800 533 7533 www thermastor com sales thermastor com
14. stuecadaustiniemmssveactenexmcecoateeeacdanet 4 Width 16 19 1 2 20 1 2 2 9 FOUN METE taiasdccantiamaccetsinadacnntensudaticezenwtnieesacatnade 5 l Height 40 40 47 3 Maintenance ccccccccceeeceeeeeeaeeeeeeaeeeeeaeeenesanens 5 3 1 Air FiIRCCS ccccccccssssccsecsessescesecsessestesessessesteseesee 4 eeu o Raa 3 1A Carbon Potassium Permanganate Filter 5 Weight 65 Lbs 70 Lbs 3 2 Checking AIMIOW succccutucatcseiiceecanesartsamexietradtieets 5 a E a E A EEN E EE S T 2 Operation AEWA N ar E EA EA T 4 2 Impeller fan Replacement ccceeeeeeeeeeeeeeaes T 2 1 Handle Assembly Procedure 5 Wiring Diagram sicscccaicendscedsnadicuwiennienteesnentuiieseaminees 8 Ga i PE E SUPPEN Packed 6 Service Parts cccccccceseceeeseeeeseeeeseeeegeeeegeeneanenes 9 i emae hadeano Ta WANNY e E E eee 11 handle brackets and handle tube two metric socket head cap screws M10 x 35mm length and 8mm hex key from the packed parts supplied with the unit Serial No Purchase Date Dealers Name ry Figure 1 Handle assembly Read the operation and maintenance instructions carefully before using this unit Proper adherence to these instructions is essential to obtain maximum benefit from your Phoenix Mini Guardian HEPA System Toll Free 1 800 533 7533 2 www thermastor com sales thermastor com 2 Locate the two mounting holes for the handle assembly on the Mini Guardian HEPA System cabinet They are
15. the bottom of the base Figure 14 Remove screws Remove the strain relief bushing holding the impeller fan cable in the top of the base s y Figure 15 Remove strain relief www thermastor com sales thermastor com 8 Using a pliers twist the tabs of the base supports to 9 Remove the four 4 mm machine screws and lock align with the slots Remove only one of the base washers securing the impeller fan supports see below Spread the base apart slightly 10 Reverse this procedure to reassemble with the new to remove the impeller fan impeller fan Figure 16 Twist tabs T eee eee eee eee eee eee eee eee eee eee eee eee eee ee eee eee Figure 17 Electrical schematic STRAIN SPEED RELIEF Pa HOUR METER BUSHINGS oe CONTROL 7 BRN GRN YEL OOOO Z CAPACITOR aaa ea vn oe Pa ET PEN MOLDED 115V PLUG W GROUND Toll Free 1 800 533 7533 8 www thermastor com sales thermastor com 5 Service Parts Qty Item Toll Free 1 800 533 7533 Part No 4024824 4021799 4024667 4024830 4024684 4024773 4024825 4024820 4022465 4024775 4024073 4026093 4021597 4021700 4024692 4024070 4024078 4024822 4024827 4024828 4024066 4024821 1 1 1 MO NON OFPFRFPFNRFPR RP RPNPRP OO PRP RP RP FB Description Air Filter Polyester 1 x 16 x 16 Air Filter Pleated 2 x 16 x 16 Air Filter HEPA 14 OD x 24 99 9
16. ust that comes off the carbon filter before it reaches the HEPA filter The refillable carbon filter is metal framed and can be refilled with carbon blend media purchased in 5 gallon buckets The amount of carbon blend media loaded into the filter can be adjusted to the particular amount of gas odor removal required 3 2 Checking Airflow The airflow is checked using a Phoenix Kestrel 3000 airflow meter placed on the designated area on the top of the unit Figure 7 Checking airflow To check airflow Remove any inlet ducting but leave the top and all filters in place Turn the unit on high The airflow meter will indicate an air speed Please set the air meter to read FPM refer to the meter instructions to set the mode To determine CFM see the chart below Kestrel 3000 FPM 100 650 600 550 500 450 400 350 300 250 200 150 400 371 343 320 286 263 235 208 182 153 120 87 CFM www thermastor com sales thermastor com Airflow on high speed with all filters clean and no ducting 3 Disengage the screw and spacer from the hole in is about 400 CFM The unit can be run with very dirty the front of the cabinet and remove the filter hold filters and virtually no flow without harming the unit The down bar operator s decision to change filters should be based on filter cost vs the unit s filtering effectiveness If airflow is 200 CFM vs 400 CFM the unit will filter particles from a
Download Pdf Manuals