1. Battery Information The thermometer operates on 1 CR2032 lithium battery included If the unit does not turn on for first use remove and then reinstall the battery Change the battery when the display becomes dim To replace battery 1 Open the battery compartment by turning the battery compartment door cover on the back of the thermometer counterclockwise using a coin in the slot 2 Remove used battery and insert new one with the sign facing up 3 Close the compartment Make sure the o ring is seated around the opening to maintain waterproof feature Note If batterydoor is not closed properly water can get into thebattery compartment causing the unit to malfunction One Year Limited Warranty This product is warranted against defects in materials or workmanship excluding batteries for one 1 year for the original purchaser from date of original purchase It does not cover damages or wear resulting from accident misuse abuse commercial use or unauthorized adjustment and or repair Should this product require service or replacement at our option while under warranty do not return to retailer Please pack the item carefully and return it prepaid along with store receipt showing date of purchase and a note explaining reason for return to the address below There are no express warranties except as listed above This warranty gives you specific legal rights and you may have other rights which vary from state to state
2. For additional product information or warranty information in Canada or elsewhere outside the USA please contact us through www taylorusa com Taylor Precision Products 2220 Entrada Del Sol Suite A Las Cruces New Mexico 88001 USA Customer Service Phone 1 575 526 0944 Customer Service Fax 1 575 526 4347 www taylorusa com Made to our exact specifications in China 9878E 12 10 Information de la pile Le thermom tre fonctionne avec 1 pile CR2032 au lithium incluse Si l appareil n allumera pour la premiere utilisation retirez et r ins rer la pile Changez la pile lorsque l affichage faiblit Pour remplacer la pile 1 Ouvrez le compartiment de pile en tournant le couvercle de la porte du compartiment de piles l arri re du thermom tre dans le sens antihoraire l aide d une pi ce de monnaie dans la fente 2 Retirez la vieille pile et ins rez en une nouvelle avec le signe ch vers le haut 3 Fermez le compartiment Assurez vous que le joint torique est assis autour de l ouverture pour maintenir la fonction tanche Remarque Si la porte de piles n est pas ferm e correctement l eau pourait p n trer dans le compartiment et l appareil fonctionnerait mal Garantie limit e d un an Taylor garantit que ce produit l exclusion de la piles est libre de tout d faut de mat riaux ou de main d oeuvre pour une p riode d un 1 an pour l acheteur original partir de la date d achat original Elle ne couvre pas
3. Presione el bot n ON OFF nuevamente para ver la luz posterior durante 5 segundos Presione sin soltar el bot n ON OFF durante 3 segundos para apagar la unidad De lo contrario la Unidad se apagar autom ticamente si la temperatura mostrada es menor que 122 F 50 C durante 5 minutos MAX MIN CURRENT Bot n de F C Presione el bot n F C para cambiar entre las escalas de temperatura Fahrenheit y Celsius Bot n de Memoria Max Min e Presione el bot n Max Min m xima m nima una vez para cambiar a la lectura de temperatura ambiente a la lectura de temperatura M xima Memoria MAX aparecer en la pantalla LCD Presione el bot n Max Min nuevamente para cambiar a la lectura de temperatura M nima Memoria MIN aparecer en la pantalla LCD e Presione el bot n Max Min una tercera vez para volver a las lecturas de temperatura ambiente e Las lecturas de Max Min se borrar n despu s de 10 segundos o cuando la unidad se apague Funci n HOLD mantener Presione el bot n HOLD mantener y la temperatura se mantendr en pantalla aparecer el cono HOLD Presi nelo nuevamente para volver a medir A E AAA PE Auto offt Feature The thermometer will turn off automatically if the displayed temperature is lower than 122 F 50 C for 5 minutes To disable the auto off feature press and hold the F 2C button an
4. les dommages ou l usure suite un accident une mauvaise utilisation tout abus utilisation commerciale ou r glage interdit et ou r paration interdite Si ce produit doit tre r par ou remplacement notre discr tion ne le retournez pas au d taillant Veuillez l emballer avec soin et le retourner frais pr pay s avec la facture du magasin indiquant la date d achat et une note expliquant la raison du retour l adresse suivante Il n y a aucune garantie expresse sauf celle indiqu e pr c demment Cette garantie vous donne des droits pr cis mais vous pouvez aussi avoir d autres droits qui varient d une juridiction l autre Pour de l information suppl mentaire sur le produit ou sur la garantie au Canada ou ailleurs l ext rieur des U veuillez nous contacter par www taylorusa com Taylor Precision Products 2220 Entrada del Sol Suite A Las Cruces NM 88001 N de t l du service client le aux U 1 575 526 0944 N de fax du service client le aux U 1 575 526 4347 www taylorusa com Fabriqu en Chine selon nos sp cifications exactes A A E Informaci n de la Bater a El term metro funciona con una bater a de litio CR2032 incluida Sila unidad no encender para usarla por primera vez retirez y reinserte la bater a Cambie la bater a cuando la pantalla se vuelva borrosa Para reemplazar la bater a 1 Abra el compartimiento de la bater a girando hacia la izquierda la tapa de la puerta d
5. los procesos de fabricaci n en l nea asi como tambi n en el laboratorio de control de calidad Aplicaciones Cient ficas y en el Laboratorio La amplia gama de temperatura la capacidad de poder cambiar entre grados Fahrenheit Celsius la actualizaci n cada dos segundos la memoria a largo plazo y el v stago de acero inoxidable son esenciales para el uso cient fico y en el laboratorio Instructions for Use ON OFF Button Press the ON OFF button once to turn the thermometer on Press the ON OFF button again to view the backlight for 5 seconas Press and hold the ON OFF button for 3 seconas to turn the thermometer off Otherwise the thermometer will turn off automatically if the displayed temperature is lower than 122 F 50 C for 5 minutes TAYLOR LIGHT la gt TOGGLE AUTOOFF N MAX MIN CURRENT oF 2C Button Press the F C button to switch between Fahrenheit and Celsius temperature scales Max Min Memory Button Press the Max Min button once to switch from ambient temperature reading to Maximum Memory temperature reading MAX appears on the LCD Press the Max Min button again to switch to Minimum Memory temperature reading MIN appears on the LCD Press the Max Min button a third time to return to ambient temperature readings The Max Min readings will clear after 10 seconds or w
6. s rvase contactarnos a trav s de www taylorusa com Taylor Precision Products 2220 Entrada del Sol Suite A Las Cruces New Mexico 88001 Tel fono para Servicio a lost Clientes 1 575 526 0944 Fax para Servicio a los Clientes 1 575 526 4347 www taylorusa com Fabricado en China seg n nuestras especificaciones exactas TAYLOR Leading the Way in Accuracy ji Digital Thermometer Instruction Manual Thank you for purchasing a Taylor thermometer Please read this instruction manual carefully before use Keep these instructions handy for future reference Applications The Taylor 9878E thermometer has been designed to meet specific needs in the food service industrial and HVAC environments It is also designed for laboratory and or scientific use Food service applications The thermometer is programmed with the highest levels of accuracy between 20 F and 150 F 7 C and 66 C a range which covers the critical food storage holding and preparation applications Of course all food service applications from freezing to deep frying fall well within the wider range of temperatures The 1 5mm stainless steel step down probe is FDA recommended and allows for fast response time and easy cleaning The recalibration feature allows adjusting for maximum accuracy and for verifying specific temperatures The antimicrobial housing and pocket tube incorporate a non toxic chemical compound that inhibits the growth of harmful pathogens wh
7. a referencia futura Aplicaciones El term metro 9878 de Taylor se ha dise ado pora satisfacer necesidades espec ficas de los mercados para servicios de alimentos industriales y de calefacci n ventilaci n y aire acondicionado Tambi n est dise ado para uso en laboratorio y o cient fico Aplicaciones para Servicios de Alimentos El term metro est programado con los m s altos niveles de precisi n entre 20 F y 150 F 7 C y 66 C una gama que abarca las aplicaciones cr ticas de almacenamiento mantenimiento y preparaciones de alimentos Por supuesto todos los usos de servicio de alimentos de la congelaci n a la fritura bajan en conformidad con la gama m s amplia de temperaturas La sonda reductora de acero inoxidable con 1 5 mm de di metro es recomendaci n de la FDA y permite un r pido tiempo de reacci n y una f cil limpieza La funci n de recalibraci n permite ajuste para tener m xima precisi n y para verificar temperaturas espec ficas La carcasa y el tubo de bolsillo antimicrobiano incorpora un compuesto qu mico no t xico que inhibe el crecimiento de bacterias causantes del mal olor lo cual minimiza la contaminaci n cruzada Aplicaciones Industriales y para Calefacci n Ventilaci n y Aire Acondicionado La funci n de memoria permite la presentaci n retardada de los datos de temperatura m x min Adem s la amplia gama de temperatura y la funci n de apagado autom tico permite mediciones precisas durante
8. d at the same time press the ON OFF button ON appears on the LCD indicating the auto off feature is disabled and the thermometer will remain ON To activate the auto off feature again repeat the instructions above ON disappears from the LCD indicating the auto off feature is active Recalibration Ifrecalibration is necessary for best results calibrate within the temperature range most commonly used Always utilize a reliable source as a benchmark when calibrating If a verified reference temperature cannot be achieved in the usage range then calibrate in an ice bath as described in Step 1 1 Suspend probe at least 1 into a slush of crushed ice and water 32 F for at least 30 seconds Keep the probe from touching the container bottom 2 Press and hold the SET button for 5 seconds The word SET will appear Then press MAX MIN and HOLD at the same time to enter Temperature Setting mode The current temperature blinks Press MAX MIN button or HOLD button to increase decrease the temperature by 1 F 0 5 C 4 To enter the recalibrated temperature press and hold the SET button for 5 seconds The LCD will turn green A pattern appears then OK 5 After 2 seconds the unit will return to normal mode To restore the default calibration temperature remove the battery for 1 minute and then replace it Note If no buttons are pressed for 30 seconas the unit w
9. el compartimiento de la bater a en la parte trasera del term metro usando una moneda en la ranura 2 Quite la bater a e introduzca una nueva con el signo hacia arriba 3 Cierre el compartimiento Aseg rese de que el anillo en O est apoyado alrededor de la abertura para mantener la caracter stica a prueba de agua Nota si la puerta del compartimiento no est correctamente cerrada puede entrar agua en el mismo haciendo Garant a limitada por un a o Taylor garantiza este producto contra defectos en los materiales y en la mano de obra excepto las bater as durante 1 un a o a partir de la fecha de compra original No cubre da os ni desgastes que sean consecuencia de accidentes uso inadecuado abuso uso comercial ni ajustes y o reparaciones no autorizadas Si este producto requiere mantenimiento o cambio a nuestro entender no la devuelva al vendedor minorista S rvase empacar el art culo cuidadosamente y env elo con el franqueo pagado junto con el recibo de la tienda en el que aparezca la fecha de compra y una nota explicando el motivo de la devoluci n a la direcci n abajo No existen garant as expresas excepto las enunciadas anteriormente Esta garant a le otorga derechos legales espec ficos y es posible que usted tenga otros derechos que varien de un estado a otro Para obtener informaci n adicional sobre el producto o informaci n de la garant a en Canad o en otro sitio fuera de los EE UU
10. hen the thermometer turns off Hold Feature Press the HOLD button and the temperature will be held the HOLD icon will appear Press again to release Conseils d Utilisation Bouton ON OFF de mise in marche Appuyez une fois pour mettre l appareil en marche Presser nouveau pour afficher le r tro clairage pendant 5 secondes Presser et gardez enfonc pendant 3 secondes pour teindre l appareil ce Sinon l appareil s arr tera MERA CAL automatiquement si la temp rature s affiche est W moins lev e de 50 C MAX MIN CURRENT 122 F pendant 5 minutes A Bouton F C Presser pour passer des chelles de temp ratures Fahrenheit et Celsius Max Min Bouton de M moire Presser une fois pour passer de la temp rature ambiante la temp rature maximale MAX appara tra sur l ACL Presser nouveau pour passer la temp rature minimale MIN appara tra sur l ACL Presser une troisi me fois pour retourner la temp rature ambiante Les relev s temp ratures maximale et minimale s effaceront apr s 10 secondes ou lorsque le thermom tre s arr te Fonction de Maintien Presser HOLD retenue et la temp rature sera conserv e le ic ne HOLD appara tra Presser nouveau pour d gager Instrucciones Para El Uso Bot n ON OFF encendido apagado Presione el bot n ON OFF una vez para encender la unidad
11. ich minimizes cross contamination Industrial and HVAC applications The memory feature permits delayed retrieval of max min data In addition the wide temperature range and automatic off feature permits accurate measurements during on line manufacturing processes as well as in a quality control lab Scientific and laboratory applications The wide temperature range Fahrenheit Celsius switchability minimum maximum memory feature and stainless steel stem are essential for scientific and laboratory use TAYLOR Leading the Way in Accuracy 9878E Thermometre Numerique Manuel d instructions Merci de votre achat d un thermom tre num rique Taylor Veuillez lire attentivement votre manuel d instructions avant d utiliser l appareil Conservez ces instructions port e de la main titre de r f rence Usages Le thermom tre Taylor 9878 a t con u por r pondre a des besoins sp cifiques des services alimentaires de l industrie alimentaire et des marches de chauffage ventilation et climatisation CVC II peut galement tre utilis en laboratoire et ou des fins scientifiques Utilisation des fins alimentaires Le thermom tre est programm pour obtenir la plus grande pr cision pour des temp ratures entre 7 C et 66 C 20 F et 150 F une plage qui couvre le stockage critique la manipulation et la pr paration des aliments Naturellement toutes les applications des fins alimentaires de la cong lation
12. ill automatically return to normal mode w o Use The Pocket Case As A Holder To avoid burns near heat insert the stem into the pocket holder s clip and use the pocket holder as a handle Fonction Auto Off arr t automatique L appareil s arr tera automatiquement si la temp rature s affiche est moins lev e de 50 C 122 F pendant 5 minutes Pour d sactiver la fonction Auto Off presser et gardez enfonc F C et en m me temps presser ON OFF ON appara tra l ACL indiquant la fonction Auto Ofh est d sactiv et le thermom tre restera en marche Pour active la fonction Auto Off nouveau r p tez les tapes pr c dentes ON disparaisse de l ACL indiquant la fonction Auto Off est activ Recalibrage Si recalibrage est n cessaire pour les meilleurs r sultats calibrera dans une plage de temp rature le plus utilis e g n ralement Utilisez toujours une source fiable comme point de r f rence en calibrant Si une temp rature v rifi e de r f rence ne peut pas tre r alis e dans la plage d utilisation calibrez alors dans un bain de glace tel qu indiqu l tape 1 1 Suspendez la sonde au moins 1 po 2 54 cm dans une barbotine de glace concass e et d eau 32 F 0 C pendant au moins 30 secondes Il est important que le bout du thermom tre ne touche pas le fond du contenant 2 Appuyez et gardez enfonc sur le bouton SET r gler penda
13. la cuisson la friture tombent tout fait en conformit avec l ventail des temp ratures La sonde d abaissement d acier inoxydable avec diam tre de 1 5 mm tel que recommand par la FDA et permet d obtenir un temps de r ponse rapide et d effectuer un nettoyage facile La fonction de recalibrage permet d obtenir une pr cision maximale et de v rifier des temp ratures sp cifiques Le boftier et le support de poche incorpore un compos chimique non toxique qui pr vient la croissance de pathog nes dangereux ce qui r duit la contamination crois e Usage industriel et dans les marches de chauffage ventilation et climatisation CVC La caract ristique de la m moire permet d obtenir des donn es max min diff r es De plus l importante plage de temp rature et la fonction d arr t automatique assurent des mesures pr cises au cours de processus de fabrication en ligne de m me que dans les laboratoires de contr le de la qualit Usage scientifique et en laboratoire L importante plage de temp rature le passage Celsius Fahrenheit fonction de m moire max min et la tige d acier inoxydable sont essentiels pour tout usage scientifique et en laboratoire TAYLOR Leading the Way in Accuracy is Term metro Digital Instrucciones Para El Uso Gracias por comprar una term metro de Taylor Antes de usarla s rvase leer con atenci n este manual de instrucciones Guarde estas instrucciones en un lugar de f cil acceso por
14. la temperatura recalibra predeterminada quite la bater a para 1 minuto y despu s reemplazar Nota Sino presiona ning n bot n en 30 segundos la unidad volver n autom ticamente a modo normal Para Usar El Estuche De Bolsillo Como Un Soporte Para evitar quemaduras cuando est junto al fuego introduzca el v stago en la llave incorporada a la funda y utilice el soporte de la funda como asa
15. nt 5 secondes Le mot SET appara tra Puis appuyez sur MAX MIN et Hold en m me temps pour entrer dans le mode de r glage de la temp rature L affichage de temp rature actuelle clignote 3 Appuyez sur MAX MIN 4 ou Hold pour augmenter r duire la temp rature d un degr F 0 5 C 4 Pour entrer la temp rature recalibrera appuyez et gardez enfonc sur le bouton SET pendant 5 secondes L ACL tournera le vert Un motif appara tra puis OK 5 Apr s 2 secondes l appareil reviendra mode normal 6 Pour revenir la temp rature recalibrera par d faut retirez la pile pour 1 minute et r ins rer la pile Remarque Si aucune touche n est enfonc e pendant 30 secondes l appareil reviendra automatiquement mode normal Pour Utiliser L tui de Poche Comme Support Pour viter les br lures pr s de la chaleur ins rez la tige dans la cl int gr e du support de poche et utilisez le support de poche comme poign e Caracter stica de Apagado Autom tico Este term metro se apagar autom ticamente si la temperatura mostrada es menor que 122 F 50 C durante 5 minutos Para desactivar la caracter stica de apagado autom tico presione sin soltar el bot n F C y al mismo tiempo presione el bot n ON OFF encendido apagado ON aparecer en la pantalla LCD indicando que la caracter stica de apagado autom tico es desactivado y el term met
16. ro seguir ON encendida Para activar la caracter stica de apagado autom tico nuevamente repita los pasos anteriores ON encendida desaparece de la pantalla LCD indicando que la caracter stica de apagado autom tico es activado Calibraci n Si es necesario recalibrar para mejores resultados calibre en el rango de la temperatura m s usada Siempre utilice una fuente confiable come punto de referencia cuando calibre Si una temperatura verificada no puede ser obtenida en el rango de mayor uso entonces calibre en un ba o de hielo seg n lo descrito en el paso 1 1 Suspenda la sonda al menos 1 2 5 cm en una mezcla de hielo y agua 32 F 0 C durante al menos 30 segundos Evite que la sonda toque el fondo del recipiente 2 Presi nelo sin soltar durante 5 segundos el bot n SET configurar Aparecer la palabra SET Luego presione los botones MAX MIN y Hold al mismo tiempo para ingresar al modo de definici n de la temperatura La pantalla LCD dar vuelta a rojo La temperatura actual parpadea 3 Presione los botones Max MIN o Hold para aumentar o disminuir la temperatura en 1 grado F 0 5 C 4 Para ingresar la temperatura recalibra presi nelo sin soltar durante 5 segundos el bot n SET La pantalla LED dar vuelta a verde Aparecer un patr n de rayitas luego OK 5 Despu s de 2 segundos la unidad volver n a modo normal 6 Para regresar a