Home

Sunbeam 2585 User's Manual

image

Contents

1. Have unit serviced collector cell plates is normal with use even after cleaning 2 Blowing smoke directly into the front grill is not a test for unit performance quite easily The chart below lists potential problems 347166 001 Cabinet Top PARTS MODEL NO 2585 SUNBEAM TABLE TOP ELECTRONIC AIR CLEANER MODEL 2585 TABLE TOP ELECTRONIC AIR CLEANER 5 MANUAL The Model Number will be found on the name plate attached to the bottom of the SUNBEAM Electronic Air Cleaner Always mention the Model Number when requesting service or repair parts for your SUN BEAM Electronic Air Cleaner WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOLLOWING INFORMATION 1 Part Number 3 Model Number 2585 4 Name of ltem SUNBEAM Table Top HOW TO ORDER Electronic Air Cleaner REPAIR PARTS Sunbeam Sunbeam Oster Household Products Distributed by Sunbeam Oster Household Products Schaumburg il 60173 Committed To Our Environment Printed on Recycled Paper aw FORM 147102401
2. MODEL 2585 OWNER S MANUAL TABLE TOP ELECTRONIC AIR CLEANER CAUTION READ AND SAVE THESE INSTRUCTIONS OPERATING INSTRUCTIONS REPLACEMENT PARTS Any questions or comments Call 1 800 526 2832 Mon Fri 8 a m 4 p m Central Time HOW YOUR SUNBEAM INSTRUCTIONS ELECTRONIC AIR CLEANER WORKS Remove plastic bag covering the air cleaner The air around you is filled with thousands of particles of air pollution Some of the pollutants dust smoke and lint are visible to the naked eye but most of the pollutants pollen and bacteria to name a few are microscopic in size Your SUNBEAM electronic air cleaner has been designed to let you enjoy a refresh ing experience in clean air living OPERATION B Select location for air cleaner with electrical outlet nearby Remember air cleaner must be placed so there is unobstructed free circulation of air into and out of the unit Polluted air enters the air cleaner through the front Figure 1 The aluminum pre filter 1 Figure 2 on the inside of the front grill of the unit will help remove some of the large particles of pollution as dirty air is drawn in i cul A Plug the power cord into any standard household Once inside the unit the pollution particles in the dirty electrical outlet See data label on bottom of unit air receive a powerful positive electrical charge as for electrical specifications and power the
3. ional arcing sound is normal when operating the unit immediately after cleaning the cell and Figure 17 should stop after a few minutes of operation TROUBLESHOOTING LIST Manv times service problems that appear to be major can be solved and how to correct them Remember check the simple things first CONDITION Unit fails to turn on Unit does not operate at Low speed Unit does not remove pollutants Unit sparks crackles and pops Unit still does not operate properly NOTES 1 Discoloration of aluminum WHAT TO CHECK 1 Power cord 2 On Off Switch 3 Cabinet Top is properly installed 4 Cell is properly installed Setting of On Off switch lonizer Collector Cell lonizer Collector Cell Re check the above points WHAT TO DO 1 Plug in power cord 2 Set On Off switch for desired blower speed 3 Refer to Item D Page 4 4 To properly install the cell make sure the side of the cell with three notches at the bottom is located next to the switch Set On Off switch on High Run unit for one minute and reset On Off switch at Low speed Wash ionizer collector cell by following the directions listed in To Clean Cell Operate unit for one week remove the cell and look at the cell If operating correctly the cell will have a collection of adhered pollutants attached to the plates of the cell Wash ionizer collector cell Make sure cell is thoroughiv dry
4. only one way If the plug collecting cell Should prolonged or continuous arc does not fit fully in the outlet reverse the plug If it ing occur the ionizing collecting cell should be still does not fit contact a qualified electrician Do thoroughly cleaned and dried See Cleaning In not attempt to defeat this safety feature structions CARE CABINET CABINET You should treat the cabinet of your air cleaner as you would any other piece of fine furniture Soft cloths and furniture polish will keep it clean and attractive for many years OZONE Under normal operating conditions all electrostatic air cleaners produce minute quantities of ozone as an incidental by product as do televisions and other electrical appliances Scientific measurements taken with the most accurate equipment available show the range of ozone emitted from a Sunbeam electronic air cleaner is between 005 and 02 ppm This is between 1 20 and I 5 of the established safe limits of 0 1 ppm is a negligible figure in fact if this amount of ozone is considered to be harmful it is dangerous to take an afternoon walk in the park on a summer day TO REMOVE CELL FOR CLEANING Cell will need cleaning about every four to eight weeks when air cleaner is in constant use A Turn off unit and unplug from electrical power source B Remove cabinet top Cabinet top is easilv removed bv pressing down on tab located on top of front grill Fig 4 while pressing d
5. own on tab with one hand slide cabinet top with other hand slowlv toward front grill about one inch until unlocked Cabinet top can now be lifted up and off Figure 4 C Push cell locking latch Figure 5 awav from cell while lifting cell out of the cabinet using the two small handles on the top of the cell Figure 6 CELL HANDLE Figure 5 CELL HANDLE Figure 6 D Slide pre filter upward from front of cell Figure 7 Figure 7 E Slide charcoal filter upward from back of Figure 8 Figure 8 REPLACEMENT OF CHARCOAL FILTER ACTIVATED CHARCOAL FILTER HELPS REMOVE HOUSEHOLD ODORS Washing the charcoal filter with soap and water will destroy its ability to adsorb odor However lint and dirt build up can be removed with a vacuum cleaner using a brush attachment Odor adsorption effectiveness will gradually deterio rate and the charcoal filter should be replaced every three months TO CLEAN CELL NOTE When handling collecting cell extreme care should be taken so fine ionizing wires and metal plates are not damaged Do not wash charcoal filter A Slide out pre filter located on front of cell Rinse thoroughly with clean warm water Set aside to dry B Use dishwashing detergent and the hottest water available to make a good soaking solution NOTE If cell is extremely dirty spray the cell with a household cleaning agent such as 409 Fantastik or Lysol let soak five 5 minute
6. s before proceeding to washing instructions C Completely immerse the cell and soak for 20 to 30 minutes D After the cell has soaked sufficiently it should be shaken vigorously in water until clean Figure 9 Figure 9 E Thoroughly rinse both sides of cell If a sprayer is available spray with water Figure 10 Check to make sure cell plates are clean F Repeat C to E if necessary Figure 10 Shake as much water out of the cell as possible and allow at least one hour for cell to dry H Check to make sure cell is thoroughly dry and replace in unit as described below TO REPLACE CELL AFTER CLEANING NOTE Use label located on top of cell for proper placement of filters into cell and for replacing cell into unit Unit will not operate properly if cell is not replaced correctly D Replace cabinet top by positioning over the unit A Slide the pre filter in the slots provided in the front Figure 14 Gently slide top forward until top of the cell Figure 11 engages locking tabs Figure 15 Slide top until flush with the back of the unit Figure 16 Figure 11 B Slide the charcoal filter in the slots provided in the back of the cell Figure 12 Figure 14 Figure 12 C Using cell handles align cell with the ribs on the inside cabinet wall Figure 13 Gently slide cell into place Figure 15 CELL HANDLE Figure 13 Figure 16 NOTE An occas
7. y pass through the ionizing section 2 The positive sumption charged particles then enter a collecting section 3 with alternately charged positive and negative ground plates The particles are repelled from the positive plates and attracted to the oppositely charged plates and remain there through natural adhesion until re moved by the washing process The air then passes through a charcoal filter 4 that helps remove house hold odors Next the electronically cleaned air passes back into the room through the top grill B Turn unit on by turning the On Off switch to the desired blower speed Low Medium or High See Figure 3 Until your unit is adequately broken in blower motor speed should be set on High for one minute initially before switching to desired setting Your electronic air cleaner is designed for continuous operation peak effi ciency is obtained if the air cleaner remains on constantly Figure 1 TNS 4 OPTIONAL CHARCOAL 1 PRE FILTER 2 IONIZER 3 COLLECTOR AFTER FILTER MEDIUM E VERO tez e HIGH T ni IR OFF SA Figure 3 NOTE You may notice an occasional infrequent Figure 2 sharp snapping sound coming from the unit This is This appliance has a polarized plug one blade is a normal occurrence called arcing and results as wider than the other As a safety feature this plug large particles of dust are collected in the will fit in a polarized outlet