Home

Stovax Brunel 8050 User's Manual

image

Contents

1. Brunel Mk III Conventional Flue With upgradeable control valve Instructions for Use Installation and Servicing For use in GB IE Great Britain and Eire This appliance has been certified for use in countries other than those stated To install this appliance in these countries it is essential to obtain the translated instructions and in some cases the appliance will require modification Contact Gazco for further information IMPORTANT Do not attempt to burn rubbish in this fire This stove must only be operated with the door secured firmly in position The outer casing of this stove will become hot whilst in operation it is therefore recommended that the appliance be guarded to protect the young and infirm using a suitable guard Ensure that fabrics such as curtains are not positioned above or near to the stoves outer casing Please read these Instructions carefully and keep them in a safe place They will be needed when servicing the fire The commissioning sheet found on page 3 should be completed by the installer PRO0595 Issue 4 August 2008 CONTENTS COVERING THE FOLLOWING MODELS BRUNEL 8050 P8050 PAGE APPLIANCE COMMISIONING CHECKLIST 3 USER INSTRUCTIONS 4 INSTALLATION INSTRUCTIONS 8 Technical Specifications 8 Site Requirements 9 Installation 10 Commissioning 13 SERVICING INSTRUCTIONS 14 Servicing Requirements 14 Fault Finding 14 How to replace parts 15 Basic spare parts list 18 Service Records 19
2. APPLIANCE COMMISSIONING CHECKLIST IMPORTANT NOTICE Explain the operation of the appliance to the end user hand the completed instructions to them for safe keeping as the information will be required when making any guaranteed claims FLUE CHECK Flue is correct for appliance Flue flow test 3 Spillage test GAS CHECK Gas soundness amp let by test Standing pressure test Appliance working pressure on High Setting NB All other gas appliances must be operating on full Gas rate Does ventilation meet appliance requirements Have controls been upgraded Upgradeable models only 8455 Standard 8456 Programmable Thermostatic and Timer DEALER AND INSTALLER INFORMATION Gas Type Installation Company Contact No Engineer Date of Purchase Contact No Model No Corgi Reg No Serial No eese liis Date of Installation This product is guaranteed for 2 years from the date of installation as set out in the terms and conditions of sale between Gazco and your local Gazco dealer This guarantee will be invalid to the extent permitted by law if the above Appliance Commissioning Checklist is not fully completed by the installer and available for inspection by a Gazco engineer The guarantee will only be valid during the second year to the extent permitted by law if the annual service recommended in the Instructions for Use has been completed by a Corgi registered engineer and a copy of
3. IS INTENDED TO BE USED ON PROPANE G31 THE AERATION PLATE SUPPLIED MUST BE FITTED FOR DETAILS OF CHANGING AERATION PLATES REFER TO SECTION 29 FOR DETAILS OF CHANGING BETWEEN GAS TYPES REFER TO SECTION 30 1 SAFETY PRECAUTIONS This appliance must be installed in accordance with the rules in force and used only in a sufficiently ventilated space Place read these instructions before installation and use of this appliance All the instructions must be left intact with the user In your own interest and those of safety this appliance 24 must be installed by a competent person in accordance with local and national codes of practice Failure to install the appliance correctly could lead to prosecution This appliance is intended for use on a governed gas installation and set to the required pressure Keep all plastic bags away from young children 2 5 Do not place any object on or near to the stove Allow adequate clearance above the stove see Technical Specification The stove is fitted with the Gazco Flue Sure System which will act to cut off the gas supply to the appliance in the event of incorrect operation of the flue If the system acts to 2 6 shut off the gas supply this indicates that there is insufficient flue pull If this occurs a minimum of 10 minutes should be allowed before trying to relight Continued operation of this safety device means that there may be a serious problem with the flue system a qualified
4. ceramic coals rear panel fuel bed and burner cover gasket Handle these components with care as they are fragile 5 3 The ceramic coals and fuel bed can be cleaned using a vacuum cleaner with a soft brush attachment It is advisable not to clean the cover gasket as this is very fragile Ensure all debris is removed from the burner ports 5 4 Replace the ceramics referring to section 6 6 FUEL BED ARRANGEMENT 6 1 Place the white ceramic cover gasket onto the burner Ensure the holes align with the burner ports Diagram 4 ARO0898 6 2 Place the fuel bed over the burner tallest part towards the rear of the firebox Diagram 5 AR0899 6 3 Carefully feed the rear panel into the firebox and engage it between the two locating brackets Slide the panel down behind the fuel bed Diagram 6 USER INSTRUCTIONS 6 6 ARO900 6 4 Place three coals equally spaced on the rear of the fuel bed so they touch the rear panel Diagram 7 6 7 7 1 ARO901 6 5 Place five coals on the front of the fuel bed so they rest on the front coal effect and lean against the vertical fingers Diagram 8 8 1 ARO902 Place the remaining four coals between the two rows of coals Rotate the coals to ensure they are secure on the fuel bed Diagram 9 AR0903 Close the door and tighten the bolt and domed nut NOTE ENSURE THAT THE COALS ARE POSITIONED AS DETAILED ABOVE ONLY USE THE CORRECT AMOUNT OF COALS
5. the appliance to a maximum and check that the supply pressure is as stated on the databadge Turn the gas off and replace the test point screw Turn the gas on and check the test point for leaks NOTE The stove is also suitable for installation onto a fireplace opening The following method illustrates how this can be achieved with the aid of the optional closure plate and spigot extension Ensure that the fireplace dimensions are shown in Diagram 4 INSTALLATION INSTRUCTIONS INSTALLATION 2 7 2 8 2 9 2 10 3 1 Place the closure plate against the fireplace opening Ensure there is sufficient overlap around the perimeter to allow a fume tight seal to be made Cut straight across the top of the plate if trimming is required Seal the plate to the opening and the hearth with suitable heat resisting material Secure the spigot extension to the engine assembly and seal with heat resisting tape or similar Position the engine assembly ensuring the 50mm rear clearance is maintained Proceed with the installation as detailed in points 2 2 to 2 6 above Secure the lip plate to the underside of the stove with the two bolts provided 3 FUELBED ARRANGEMENT Place the white ceramic cover gasket onto the burner Ensure the holes align with the burner ports Diagram 5 AR0898 11 3 2 3 3 3 4 Place the fuel bed over the burner tallest part towards the rear of the fire
6. AS SPECIFIED IN THE DIAGRAMS 7 GAZCO FLUE SURE SYSTEM The stove is fitted with the Gazco Flue Sure System which will act to cut off the gas supply to the burners in the event of incorrect operation of the flue If the system acts to cut off the gas supply this indicates that there is insufficient flue pull If this occurs a minimum of 10 minutes should be allowed before trying to relight Continued operation of this safety device means there may be a serious problem with the flue system A qualified gas engineer should inspect this Do not use the stove until an engineer says it is safe to do so 8 THE FLAME FAILURE DEVICE This is a safety feature incorporated in all GAZCO fires which automatically switches off the gas supply if the pilot light goes out and fails to heat the thermocouple 9 1 10 1 11 1 12 1 USER INSTRUCTIONS 9 RUNNING IN The surface coating on your GAZCO stove will burn off during the first 24 hours of operation on high producing a harmless and temporary odour If the odour persists ask your retail for advice 10 SERVICING A qualified gas engineer must service the stove every 12 months In all correspondence always quote the appliance type and the serial number that may be found on the data badge on the appliance 11 VENTILATION Any purpose provided ventilation should be checked periodically to ensure that it is free from obstruction 12 INSTALLATION DETAILS To assist in a
7. DP 6p 8 EY o a Do x 5 a a oO o o a E E 2 and retry 2o 2E oc d c c oO EX E e io 9E O Consult Section g gt o s 5 v g S S a o 14 No Yes Is the gas turned on to the appliance No E e oO e gt S E ee oe uz o 9 BE g 9 p U Is the gas pressure correct No Correct and Yes Yes n B a s Sb s o Sb 5 a Has the system got any air in it 5 D 2 ks c S m 3 a m Pd g gt 2 s o E s x js D o E 9 g a a o E s ES o op E ES Is 2 x c E g g o Pa 2 2 a 3 S o G gt ob c S D a p GS E o E AR0097 SYSTEM OK CHART x a n Zz ul uu N SERVICING INSTRUCTIONS FAULT FINDING CHARTS MO WALSAS spuooas Z UEY 1 1e 18 siu sI OI YM Sjnus Pun Sew pun peaagu aw yO un spuooes 09 jo tunuurxeui e 10 uny Anal pue uon uuo5 y ue1u8i gspuodas Z uey 19318 Sip S ID P pM sinus yun Bew nun JeAraqu uun yo un spuooes 09 SOA uey aaow ou JO uns iedpeqeep y uo pas ainssaid y ye se8 y si N uo Suiuuni ay 94 YIM jun Seu asueyd Auge Aejs 1O Id IIM ejdnooouueui eoejdey A PA JO peq u poo8 uono uuoo dnooouui u s Anal pue 1224107 a1 y o pea u
8. ajeA ayy dO ease ay ueop eds y 10us p noo yory dja 3005 eoo 279 Ajquuesse 1o id ay punoue siiqap ou st j un insu3 Mi vdS ON MOJHD IVNOILON 14 NOILINDI 15 1 1 12 2 1 2 2 2 3 2 4 2 5 SERVICING INSTRUCTIONS REPLACING PARTS 1 GENERAL This appliance must be serviced at least once a year by a competent person All principal components can be replaced without removing the stove from its installation although it is essential that the gas supply to the appliance is turned off at the isolation device before proceeding further 2 PILOT UNIT Turn the gas supply off at the isolation device To open the doors Slacken the domed nut on the upper door and loosen the bolt from behind the latch Undo the pilot compression nut Remove the ignition lead from the electrode by gently pulling downwards Undo the thermocouple from the back of the gas valve Diagram 1 D I ARO895 Remove the two screws securing the pilot unit Cut the cable tie securing the ignition lead taking care not to damage it The unit can now be removed from beneath the stove When replacing the new pilot unit Ensure the thermocouple follows the same route as the original one Secure the ignition lead to the pilot pipe with a new cable tie Reconnect the thermocouple ignition lead and pipe Turn on the gas supply and check for leaks Close the doors and tighten the bol
9. box Diagram 6 AR0899 Carefully feed the rear panel into the firebox and engage it between the two locating brackets Slide the panel down behind the fuel bed Diagram 7 ARO900 Place three coals equally spaced on the rear of the fuel bed so they touch the rear panel Diagram 8 ARO901 INSTALLATION INSTRUCTIONS INSTALLATION 3 5 Place five coals on the front of the fuel bed so they rest on the front coal effect and lean against the vertical fingers Diagram 9 ARO902 3 6 Place the remaining four coals between the two rows of coals Rotate the coals to ensure they are secure on the fuel bed Diagram 10 AR0903 3 7 Close the door and tighten the bolt and domed nut NOTE ENSURE THAT THE COALS ARE POSITIONED AS DETAILED ABOVE ONLY USE THE CORRECT AMOUNT OF COALS AS SPECIFIED IN THE DIAGRAMS 4 LIGHTING 4 1 Full instructions are given in the User Section of this manual 12 1 1 1 2 INSTALLATION INSTRUCTIONS COMMISSIONING 1 COMMISSIONING Close all openable doors and windows in the room Ignite the stove and operate on maximum for 10 minutes AR0539 If there is any doubt run the stove for a further 10 minutes and repeat the test If there are any extractor fans in adjacent rooms the test must be repeated with the fans running on maximum and interconnecting doors open IF SPILLAGE PERSISTS DISCONNECT THE APPLIANCE AND SEEK EXPERT ADVICE For future reference record th
10. copper tubing and soft soldered joints can be used but must not be closer than 50mm to the base of the tray A means of isolating the gas supply to the appliance must be provided independent of any appliance control All supply gas pipes must be purged of any debris that may have entered prior to connection to the appliance 4 APPLIANCE LOCATION 4 1 This appliance must stand on a non combustible hearth that is at least 12mm thick and project a minimum of 50mm from the base of the stove in all directions ARO0035 4 2 This appliance must not be installed in a room that contains a bath or shower 4 3 The stove is not suitable for installation against a combustible wall all combustible materials must be removed from the area behind the stove 4 4 Ensure that all minimum clearances to combusible materials are complied with Diagrams 2 amp 2A ARO884 ARO885 In a non combustible recess attention must be given to allowing adequate clearance at the sides and rear of the stove so that a spillage test can be performed and the controls reached 1 1 1 2 1 3 1 4 1 5 1 6 1 7 1 8 2 1 2 2 INSTALLATION INSTRUCTIONS INSTALLATION IMPORTANT ENSURE THAT THE APPLIANCE IS 2 3 CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY APPLICABLE IN THE COUNTRY OF USE REFER TO DATABADGE AND TECHNICAL SPECIFICATIONS AT THE FRONT OF THE BOOKLET LPG MODELS THE APPLIANCE IS FACTORY SET TO RUN ON BUTANE G30 IF IT
11. e installation details on the Commissioning Sheet page 3 of these instructions 13 1 1 1 2 1 3 1 4 1 5 IGNITION FUNCTIONAL CHECK 1 SERVICING INSTRUCTIONS SERVICING FAULT FINDING CHARTS 1 SERVICING REQUIREMENTS This appliance must be serviced at least once a year by a competent person All tests must be serviced by best practice as described by the current CORGI recommendations Before any test are undertaken on the appliance conduct a gas soundness test for the property to ensure that there are no gas leaks prior to starting work Before any tests are undertaken on the applaince it is also recommended to fully check the operation of the appliance Special checks 1 3 1 Clean any lint or fluff from the pilot pay particular attention to the aeration hole in the side of the pilot 1 3 2 Clean away any fluff or lint from under the burner 1 3 3 Check that the spark gap on the pilot is correct Correct any faults found during the initial tests and then re commission the appliance conducting the usual safety checks Advise the customer of any remedial action taken Yes with a match ES ra S a o lt t Does the pilot light Is the control being operated correctly Yes I 9g zi O Zz zi z O a Ensure there is no debris around the pilot assembly e g soot etc which could short the spark clean the area N 8 pa amp 25 BSE cs
12. edd chad pao esu diel up Wats aa a Dealer s Stamp CORGI Registration Number Dealer s Stamp CORCI Registration Number 19 Gazco Limited Osprey Road Sowton Industrial Estate Exeter Devon England EX2 7JG Tel 01392 261999 Fax 01392 444148 E mail info gazco com A member of the Stovax Group
13. gas engineer should inspect this DO NOT USE THE STOVE UNTIL AN ENGINEER SAYS IT IS SAFE TO DO SO The Flue Sure System must not be tampered with Use only genuine Gazco replacement parts when servicing the system refer to servicing section on page 15 2 INSTALLATION OF THE STOVE Remove the outer carton Take the stove off the pallet and remove the accessory carton Position the stove ensuring all appropriate clearances are observed 10 Having run the gas supply to the stove PURGE THE SUPPLY PIPE this is essential to expel any debris that may block the gas controls Connect the gas supply to the 8mm compression elbow at the RH rear corner of the stove Diagram 3 AR0396 Check the pull of the flue system by applying a lighted smoke pellet to the flue system opening If there is a definite flow into the chimney proceed with the installation if not warm the chimney for a few minutes IF THERE IS STILL NO DEFINITE FLOW THE FLUE MAY REQUIRE ATTENTION SEEK EXPERT ADVICE The flue system may now be connected to the stove Ensure that all joints are sealed with a suitable fire resistant sealant It is also recommended that a physical retention method be used at the flue spigot joint self tapping screws being favoured Connect a suitable pressure gauge to the test point located on the inlet fitting Turn the gas supply on Light the appliance and check all gas joints for possible leaks Turn
14. ilot Unit Control Valve Injector Aeration Plate Databadge The relevant parts can be ordered from the parts list always quote the appliance type and serial number when ordering spare parts NOTE THE CONTROL VALVE IS FACTORY PRESET FOR CORRECT GAS TYPE AND MODEL A NEW UNIT WILL NEED TO BE ORDERED WHEN CHANGING BETWEEN GAS TYPES 10 SHORT SPAES LIST APPLIANCE 8050 P8050 NG LPG N m component Jo suewER UNT 229 czs2zs GZ3279 GZ3278 G20 G30 N A GZ3269 C G25 G31 GZ3270 D GZ2003 A GC0056 CE0359 SERVICE RECORDS 1ST SERVICE 2ND SERVICE Next Service due _ SIGNED PET iad ba kaqa Gee eee E Dealer s Stamp CORGI Registration Number Dealer s Stamp CORGI Registration Number 3RD SERVICE 4TH SERVICE Next Service due Signed eat fem gl chard a ed esee diel Da aq Wak RUE at Dealer s Stamp CORGI Registration Number Dealer s Stamp CORGI Registration Number 5TH SERVICE 6TH SERVICE Next Service due a sss chav px eR EE RW Signed coxousduesredn dette fies ts a tee as d Es Dealer s Stamp CORGI Registration Number Dealer s Stamp CORGI Registration Number 7TH SERVICE 8TH SERVICE Next Service due 0 0 0 ce eee eee eee SIGNED eT iad ba ele pee nee ee ae Dealer s Stamp CORGI Registration Number Dealer s Stamp CORGI Registration Number 9TH SERVICE 10TH SERVICE Next Service CUE osso mia set Saas Gano sae as Signed ea r
15. ion Find the sensor in the draught diverter opening and gently pull the two wires off the terminals Undo the two taptite screws and remove the sensor and the two plastic spacers Diagram 5 Refit a new sensor ensuring that the spacers are located between the sensor and the bracket replace the two leads If it has been necessary to remove the stove ensure that all disturbed gas joints are leak tested when reinstalled and repeat the flue clearance test as detailed in section 21 8 1 8 2 8 3 8 4 8 5 SERVICING INSTRUCTIONS REPLACING PARTS 8 PRIMARY AERATION PLATE Turn the gas supply off at the isolation device To open the doors Slacken the domed nut on the upper door and loosen the bolt from behind the latch Remove the two screws securing the pilot unit and undo the injector nut Diagam 6 B ARO895 Remove the four fixing screws and withdraw the burner unit Diagram 6 C The aeration plate is located on the rear of the venturi Remove the fixing screw and replace with the correct plate When replacing the plate Ensure the lower edge is hooked over the flange of the venturi Diagram 7 ARO766 Replace the burner ceramic components and check for leaks Close the doors and lock the bolts and nuts 18 AERATION PLATE GAS VALVE 9 CHANGING BETWEEN GAS TYPES In order to change between gas types it will be necessary to change the following items Burner Unit P
16. lter Replace with a new filter and push into position ensuring that it sits on the shoulder 6 3 Replace the retaining ring and push into position Replace the inlet pipe turn the gas supply on and check for leaks 5 MAGNETIC SAFETY VALVE 7 1 Turn the gas supply off at the isolation device Undo the thermocouple connection from the back of the gas valve Pull the sensor leads clear and remove the interrupter block Undo the mag valve retaining nut from the back of the control valve gently tap out the mag valve and replace with a new unit Replace the retaining nut and tighten Diagram 3 Reassemble the interrupter block and leads Secure in place with the thermocouple Turn the gas supply on and check the entire pipework and valve joints for any leaks 6 MAIN INJECTOR Turn the gas supply off at the isolation device To open the doors Slacken the domed nut on the upper door and loosen the bolt from behind the latch 72 The injector is located on the right hand side of the burner Undo the injector nut and gas valve nut 73 Remove the feed pipe Diagram4 A 17 Rotate the injector until it can be fully removed Replace with a new component Reassemble the pipe work and check for leaks Close the doors and tighten the bolts and lock nut 7 GAZCO FLUE SURE SYSTEM If the stove has been installed in a restricted location it may be necessary to remove the stove from its locat
17. ny future correspondence your installer should have completed this commissioning sheet this records the essential installation details of this appliance In all correspondence always quote the model No and serial No INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATION Covering the following models Brunel 8050 P8050 Model Gas Gas Type Nox Aeration Injector Gas Rate Input kW Country Cat Class m 3 Gros Brunel 8050 8050 Lu Natural Gas G20 4x axie 043 43 2 2 25 GB IE IE E Propane G31 36x23 0167 Efficiency Class II Gas inlaat afmeting 8mm Minimum flue specification T260 N2 O D 1 Maximum flue temperature 180 C INJECTOR SIZE lt Shy b ARO889 A I im EL p i58 L Ir zi r m X LI Jj m L3 d pc L I r a zai I Mam 1 L h k al r BELES TEn C L T rl T TT i p Nu ARO0887 s AR0888 AR0521 1 1 1 2 1 3 1 4 2 1 2 2 2 3 3 1 3 2 3 3 3 4 3 5 INSTALLATION INSTRUCTIONS SITE REQUIREMENTS 1 FLUE AND CHIMNEY REQUIREMENTS The chimney or flue system must comply with the rules in force and must be a minimum of 127mm 5 in diameter The following are suitable for use with this appliance A 230mm x 230mm 9 x 9 conventional brick or stone built chimney B A precast flue system used in conjunction with vertical closure plate and flue spigot extention C A metal flue box used in conjunc
18. orum sdumiy 10 y1omadid y YUM sr uu qoid JOU IA gun 1oid y edueu aded uo ureideip 92s ul8u 1201100 ay JO aure 1ojId aui s gaspeqeiep ayy uo p s ainssaid sed ay si Suruuni lojid ou PM 08 Sume a10jeq spuodas Q 1sea 1e ul peusnd qou jouoo y dee pue 1o id y 1u8 1 eave ayy UL eds at 1104s p noo uptuM 7219 1oos jeoo d a Aquiasse 1o id ay puno suq p ou st aay ensu3 ASA NI LNO 3O9 334 YO LIT AVIS LON TIIM LO Ild 323HO WNOLLINNA THCY1V 3WVT14 njai pue Ajea sed pue ozaid aui e ejdos poq aajeA ayy o ozeid ay wouy duinf xeds e seoq e e ayy l e1 dO oz ld ayy WO pea po n2 ay aAoway Amjad pue 322410 squeuoduioo ozaid jo uoneoo 3221102 Joy yayD uoNesado we 10 ajpuids qouy o 3uoo pasewep 10 AlDD J p 104 29u Anjos pue 12234107 young 1ojid ayy Jasay Appauoo payesado Bulag ALa ay S Anjad Z uono s 3jnsuo n i pue pea apoipaja ay aoxjday pono ay aoejday Anas ozaid pue pea peuiquioo ayy e ejdes ON LA y ut ozaid ay wo paysejap 9 opoas e aui S IDI 2 IALA ay UBYM zeds e aay si ys0madid 1o id ay wou uutur dn eui ploy sjerd payejnsur I opomoe e Woy pea apomoaja au aroway 100d uonoeuuoo SI JO paupejap auio2aq pea uous seH ZL a8ed uo ureigeip aas ijeuozuou JouJnq 1o Id ay S optp 9 e ayy seop o id eu 4481 01 a
19. rotate anti clockwise until a click is heard and the knob is pointing at the ignition symbol Arrow B the pilot should now be lit See diagram 2 2 3 2 4 2 5 3 1 4 1 Hold in for 5 to 10 seconds and then release The pilot remains lit If the pilot does not light repeat the procedure AR0396 If the pilot still does not light after repeated attempts Contact the retailer or installer from whom the appliance was purchased Light the appliance by match as a temporary measure see Section 4 The appliance can now be turned to the high position to ignite the main burner 1 then controlled between high and low as desired THE YELLOW FLAMES WILL APPEAR WHEN THE FIRE HAS GAINED SUFFICIENT HEAT TYPICALLY 10 TO 20 MINUTES IF THE APPLIANCE IS EXTINGUISHED OR GOES OUT IN USE WAIT 3 MINUTES BEFORE ATTEMPTING TO RE LIGHT THE APPLIANCE 3 TURNING THE STOVE OFF Hold in the control knob and turn clockwise until the knob is pointing at the off position 8 LIGHTING THE STOVE WITH A MATCH Slacken the domed nut on the upper door and loosen the bolt from behind the latch The door can now be opened USER INSTRUCTIONS 4 2 Hold in the control knob and rotate anti clockwise until the knob is pointing at the ignition symbol x Apply a lighted match to the pilot hood Diagram 3 AR0897 4 3 When the pilot is lit Extinguish the match and continue to hold in the knob for 5 to 10
20. seconds 4 4 Close the door and tighten the bolt and nut with a spanner 4 5 The fire can now be operated as previously described 5 CLEANING THE STOVE WARNING DO NOT ATTEMPT TO CLEAN THE STOVE UNTIL IN A COLD CONDITION THE STOVE RETAINS ITS HEAT FOR A CONSIDERABLE TIME AFTER SHUTDOWN ADVICE ON HANDLING AND DISPOSAL OF FIRE CERAMICS The fuel effect and side panels in this appliance are made from Refractory Ceramic Fibre RCF a material which is commonly used for this application Protective clothing is not required when handling these articles but we recommend you follow normal hygiene rules of not smoking eating or drinking in the work area and always wash your hands before eating or drinking To ensure that the release of RCF fibres are kept to a minimum during installation and servicing a HEPA filtered vacuum is recommended to remove any dust accumulated in and around the appliance before and after working on it When servicing the appliance it is recommended that the replaced items are not broken up but are sealed within heavy duty polythene bags and labelled as RCF waste RCF waste is classed as stable non reactive hazardous waste and may be disposed of at a licensed landfill site Excessive exposure to these materials may cause temporary irritation to eyes skin and respiratory tract wash hands thoroughly after handling the material 5 1 Release the door as described in section 4 1 5 2 Remove the
21. the service visit report is available for inspection by a Gazco engineer 2 1 2 2 USER INSTRUCTIONS 1 GENERAL A competent person must carry out installation and servicing In all correspondence please quote the appliance type and serial number which can be found on the databadge located on a plate under the control valve Ensure that curtains are not positioned above the appliance and there is at least 300mm between the sides of the appliance and any curtains If any cracks appear in the glass panel do not use the appliance until the panel has been replaced If for any reason the flue has to be removed from the appliance the seals must be replaced in the inner spigot Do not use a garden sprinkler or hose near the terminal Do not stand or place objects on the terminal guard as this will deform it This product is guaranteed for 2 years from the date of installation as set out in the terms and conditions of sale between Gazco and your local Gazco dealer Please consult with your local Gazco dealer if you have any questions In all correspondence always quote the Model Number and Serial Number Any combustible shelves or surrounding furniture must only be fitted in accordance with the minimum dimensions detailed in diagram 1 l L L AR0887 2 LIGHTING THE APPLIANCE e Ensure the control is pointing to the off position Arrow A Diagram 2 Hold in the control knob and
22. tion with a vertical closure plate and flue spigot extention The metal flue box must be constructed to the requirements of BS 715 NOTE IF IT IS INTENDED TO FIT THE STOVE INTO AN EXISTING BRICK CHIMNEY WITHOUT A CLOSURE PLATE A 127MM LINER MUST BE USED The minimum effect height of the flue or chimney must be 3 metres 10ft The chimney or flue must be free from any obstruction Any damper plates should be removed or secured in the fully open position and no restrictor plates should be fitted The chimney should be swept immediately prior to the installation of the appliance However where it can be seen that the chimney is clean and unobstructed throughout its entire length it need not be swept 2 VENTILATION This appliance has a nominal input not exceeding 7 0kw and therefore does not normally require any additional premanent ventilation If however spillage is detected when commissioning the appliance there may be insufficient natural ventilation and additional ventilation may be required For ventilation requirements it will be necessary to refer to national and local rules in force 3 INSTALLATION OF THE GAS SUPPLY Before installation ensure that the local distribution conditions identification of the type of gas and pressure and the adjustment of the appliance are compatible Ensure that the gas supply is capable of delivering the required amount of gas and is in accordance with the rules in force Soft
23. ts and locknuts 3 1 3 2 3 3 4 1 3 IGNITION LEAD AND PIEZO Due to the method of manufacture these components can only be replaced as an integral unit Turn the gas supply off at the isolation device Pull the control knob off the gas valve spindle to reveal the piezo securing screw access holes Using a small pozidriv screwdriver Remove the two screws Diagram 2 AR0894 Pull the piezo body down and remove from the valve Disconnect the ignition lead from the electrode Diagram 1 D Replace the assembly with a new unit Refit the screws and connect the ignition lead to the electrode Check the operation of the new piezo Turn the gas supply on and with the pilot running Check for leaks especially where the two halves of the valve join Replace the control knob NOTE WHILST PERFORMING THE PIEZO REPLACEMENT YOU WILL BE BREAKING THE SEAL BETWEEN THE TOP AND BOTTOM HALVES OF THE VALVE ENSURE THAT THIS JOINT IS CORRECTLY SECURED AND LEAK TESTED 4 GAS FILTER The gas filter is located just inside the inlet boss of the control valve to replace the filter proceed as follows Turn the gas supply off at the isolation device Undo the inlet compression nut and pull the pipe clear of the valve Diagam 3 4 2 4 3 5 1 5 2 5 3 6 1 SERVICING INSTRUCTIONS REPLACING PARTS ARO320 Prise the small retaining ring out of the inlet and remove 6 2 the fi