1. 250 Turnpike Road Southborough MA 01772 If you have questions of comments please call Kaz at 800 477 0457 or email consumerrelations kaz com Stinger Kaz Inc 4411 Route 9 Hudson NY 12534 Consumer Service 800 477 0457 Fax 508 481 0509 Or visit us online at www StingerProducts com Made in USA EPA Est No 072336 NY 001 4 0800 13 4
2. CT100 OM qx 2 9 07 2 19 PM Page 1 c G ee DS a a ae E F i ITE E Outdoor Mosquito Vacuum Operation Manual Model CT100 FOR YOUR SAFETY 1 If you smell gas shut off gas to the appliance 2 If odor continues immediately call your gas supplier or your fire department 3 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliances 4 An LP cylinder not connected for use shall not be stored in the vicinity of this or any other appliance WARNING FOR OUTDOOR USE ONLY Improper installation Alteration Service or Maintenance can cause injury or property damage Read the installation operating and maintenance instructions thoroughly before installing or servicing the equipment CT100_OM qx 2 9 07 2 19 PM Page 2 3 TABLE OF CONTENTS Getting Started eee General Safety Instructions Propane Use and Safety cccccccscececeseseseseseeeseseeeeeeceeseeeseseeeeeeeeeeeeetees Paris List iiinn anren r Gaia lander 4 Assembly Instructions ccccceceseeseseseseseeeeeeeseseeeeeeeeceeaeeeeeeeeeeeeeeeeeeees 5 Mosquito Vacuum Placement ccecececeeceseseseeeseeeeeeeseseseeeeeeeeeeeeeets 6 Operational Instructions ccccececececeseseseseseeeeeeeeeeeeeeeeeeeseseteeeeeeteeeetees Remove Clean Bug Basket Shut Down Instructions ccccccecssssesssssssssssssessssscseeessseesessceesesssersavess Maintenance ni an aee Ea EREA EE Aie
3. For Best RESUS 2 seeds a e aar aa E e aE E a REA About MOSQUILOGS era aeea aaea Ea eE EAE E EAE EAER Accessories Replacement Parts we IT Troubles NOON ara ar a a aE tienes eesti 12 Warranty Information iiaee ated eee aea a a EE 13 GETTING STARTED Congratulations on your Stinger Mosquito Vacuum purchase Designed by a team of engineers and scientists the Mosquito Vacuum combines the most effective mosquito attractants known today carbon dioxide CO moisture heat contrasting color amp shape and luring scents The Mosquito Vacuum mimics human breathing by generating CO from burning propane which is commonly available for use with all outdoor barbecue grills Female mosquitoes attracted to the CO and other lures mistake the machine for a meal and are sucked into the Bug Basket by a powerful vacuum where they dehydrate and die Within 4 6 weeks the reproductive cycles of these biting pests may be interrupted and mosquito populations could be reduced in your yard This results in a more pleasant outdoor environment for you and your family This manual contains important information about the safety assembly operation use and maintenance of the Stinger Mosquito Vacuum Keep this manual for future reference and for educating any new users Safety precautions are essential when using storing and servicing the Mosquito Vacuum This product is fueled by propane gas which is invisible odorless and highly flammable Always he
4. left in the cartridge active ingredients will be exhausted 7 Set Lure Timer Setting the REPLACE LURE Timer will tell you when to replace the chemical bait to the trap Always set the timer when you install a new lure The REPLACE LURE indicator light will blink YELLOW when the lure needs to be replaced a For a 60 day lure press the REPLACE LURE button and hold 3 seconds until YELLOW indicator light blinks twice indicates a 60 day timer Figure 13 For a 30 day lure press the REPLACE LURE button and hold 1 second and Press POWER button until YELLOW indicator light blinks one time indicates a 30 day timer Figure 14 8 Ensure Bug Basket is installed properly See above INSTALL BUG BASKET SmartTemp Mode The Stinger Mosquito Vacuum is designed to function only when mosquito populations are present Mosquitoes are present when temperatures are in the range of 50 95 F If the temperature night or day is out of this range the unit enters a SmartTemp Mode where the burner shuts down to conserve gas and the fan continues to run to keep captured mosquitoes within the Bug Basket During this mode the POWER light indicator blinks GREEN The Mosquito Vacuum will automatically turn itself back on when the temperature falls back in the optimal mosquito range Figure 11B Figure 12 LY Figure 13 Figure 14 CT100_OM qx 2 9 07 2 19 PM P
5. CK PROPANE f is RED 1 Be sure propane tank is properly connected and tightened securely 2 Be sure propane tank has gas 3 Be sure propane tank valve is open CHECK BUG BASKET 7 is RED 1 Bug Basket is full See REMOVE CLEAN BUG BASKET 2 Bug Basket is not installed correctly Arrow A on Bug Basket should be in locked amp position 3 Remove Bug Basket empty and replace correctly See INSTALL BUG BASKET REPLACE LURE 3 is YELLOW 1 NOsquito by Stinger 2 in 1 Power Bait is out 2 Replace with new bait and reset CHECK PROPANE i CHECK BUG BASKET 4 blink RED 1 Service Needed 2 Call 1 800 477 0457 Unit does not seem to be catching mosquitoes 1 Be sure unit is on 2 Be sure lure and propane are filled 3 Mosquitoes become less active in higher or lower temperatures Confirm temperature is in 50 95 F range 4 Mosquito population may be low 5 Move Mosquito Vacuum to more optimum trapping area ATTENTION PLEASE DO NOT RETURN THIS PRODUCT TO THE STORE CONTACT KAZ CONSUMER RELATIONS WE CAN ASSIST YOU CALL 1 800 477 0457 Email consumerrelations kaz com or write Kaz Inc Consumer Relations Dept 250 Turnpike Rd Southborough MA 01772 12 a CT100_OM qx 2 9 07 2 19 PM Page 13 LIMITED WARRANTY Kaz Inc warranties to the original purchaser that this product is free from defective materials and workmanship This warranty is limited to remedy any defective part for
6. ING The installation must conform with local codes or in the absence of local codes with the National Fuel Gas Code ANSI 2223 1 for US and with the CAN1 B149 for Canada The LP Gas cylinder used shall be constructed and marked in accordance with the specifications for LP Gas cylinders of the U S Department of Transportation DOT 16 WARNING Do not place the Mosquito Vacuum under overhead unprotected combustible construction Maintain a minimum of 5 feet clearance around the perimeter of the Mosquito Vacuum when in use 17 WARNING Inspect the hose before each use of the Mosquito Vacuum If it is evident there is excessive abrasion or wear or the hose is cut it must be replaced prior to operating the Mosquito Vacuum The replacement hose shall be that specified by the manufacturer 18 WARNING The Mosquito Vacuum shall be used outdoors and only in a well ventilated space and shall not be used in a building garage or any other enclosed area 19 CAUTION The Mosquito Vacuum is not intended to be installed in or on recreational vehicles and or boats 20 CAUTION The Mosquito Vacuum should be stored indoors when not in use and kept away from children 21 CAUTION If the Mosquito Vacuum is not in use the gas must be turned off at the supply cylinder Storage of the Mosquito Vacuum indoors is permissible only if the cylinder is disconnected and removed Cylinders must be stored outdoors out of reach of children and must not be stored in a buildi
7. Right Upright Pedestals Push down to secure Figure 3 4 Select and place the Mosquito Vacuum in the optimum location Refer to the following MOSQUITO VACUUM PLACEMENT section for recommendations 5 Place Propane Tank on Base Place a full 20 Ib tank of propane on the base The threaded connection should be facing the handle area on the trap Figure 4 6 Attach the Gas Regulator Valve to the Propane Tank Remove the protective plastic cap from the threaded hose connection on the propane tank and attach regulator turning clockwise to tighten Note The hose fitting must be securely hand tightened to prevent gas leakage Figure 5 Figure 4 CT100_OM qx 2 9 07 2 19 PM Page 6 ASSEMBLY INSTRUCTIONS cont d 7 Install Bug Basket Ensure Bug Basket is completely closed before installing bottom mesh cage is twisted shut and door is hinged closed Line up the arrow A with the unlock symbol ta and drop into the top of the Vacuum Head Figures 6 amp 7 Bug Basket should sit flush with top of Vacuum Head Turn Bug Basket handle counter clockwise 4 180 until the arrow A aligns with the lock symbol The Bug Basket will twist open in the unit and be ready to capture mosquitoes as you lock it in place s m Kg P 24 P The placement of the Stinger Mosquito Vacuum is critical to catching mosquitoes The largest amount of mosquitoes will b
8. a period of 1 year from date of original date of purchase Retain your original receipt as proof of purchase This warranty does not apply to problems arising from abnormal wear or failure to adhere to the enclosed instructions In addition the foregoing warranty shall not applied to product that have been defaced subjected to negligence accident improper operation maintenance or storage product damaged by circumstances beyond Kaz Inc s control or products modified including but not limited to modifications through the use of unauthorized parts or attachments or repaired by anyone other than Kaz Inc or its designee This warranty gives does not apply to this unit if purchased outside the United States excluding Canada In no case shall Kaz Inc be liable for any incidental punitive consequential or any other damages of any kind for breach of this or any other warranty expressed or implied whatsoever Some states do not allow limitation on how long an implied warranty lasts so the above limitation or exclusion may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state If you experience unsatisfactory operation first refer to the TROUBLESHOOTING section and follow those suggestions If Troubleshooting doesn t work please contact Kaz for repair service instructions Call 1 800 477 0457 Email consumerrelations kaz com Write Kaz Inc Consumer Relations Dept
9. age 9 REMOVE CLEAN BUG BASKET 1 To Remove Bug Basket Turn Bug Basket handle gure 15 clockwise so the arrow on the Bug Basket aligns with the Unlocked symbol a on the top of the Vacuum head Figure 15 The Bug Basket is designed to twist close so that no live mosquitoes can escape when the Bug Basket is removed Pull Vv straight up CHECK BUG BASKET indicator will light RED while Bug Basket is removed b 2 To Empty Clean Bug Basket Unhook the small latch on the bottom mesh door and empty mosquitoes STINGER Figures 16 amp 17 Gently tap Bug Basket on the ground to completely empty If mosquitoes are still alive leave Bug Basket in the sun for a few hours so the insects dehydrate Empty as described above If necessary use small brush to remove any debris 3 To Replace Bug Basket Ensure bottom mesh door of Bug Basket is snapped securely in place and the Basket is in the closed position Line up the arrow on the Bug Basket with the Unlocked symbol ts on the top of the Vacuum head and drop the Bug Basket in the intake area Turn the Bug Basket handle counter clockwise until the arrow on the Bug Basket aligns with the Locked symbol amp on the Vacuum head Figure 18 The Bug Basket will twist open and be ready to capture mosquitoes as you lock it in place Figure 18 CT100_OM qx 2 9 07 2 19 PM Page 10 SHUT DOWN INSTRUCTIONS 1 Close the
10. ditional times automatically If unable to start an error light will be illuminated on the User Control Panel See TROUBLESHOOTING in this manual or on the unit for help Install the NOsquito by Stinger 2 in 1 Power Bait Use only NOsquito by Stinger lures Your Stinger Mosquito Vacuum includes one 30 day NOsquito by Stinger 2 in 1 Power Bait NCL2 This bait has 2 active ingredients designed to attract a wider range of mosquitoes including those which may transmit West Nile Virus encephalitis and other diseases away from you and your family and to this device that can kill these potentially dangerous pests The lure has a slow release and will emit an octenol and lactic acid scented bait continuously for 30 days a To install remove tape on top of bait and activate by Figure 11A snapping the cartridge in half fold over and secure both ends together by interlocking the two small tabs found lt at either end Figure 11A CT100 OM qx 2 9 07 2 19 PM Page 8 OPERATIONAL INSTRUCTIONS cont d Open Lure Chamber by pulling door down at the bottom of exhaust ring Figure 11B Fit the lure cartridge into the Chamber and push the lure door closed until it locks in place Purchased additional lures can be stored in the Extra Lure Storage Drawer for convenience Figure 12 To remove simply discard bait appropriately in a trash receptacle Note although there may residue
11. e captured by positioning the Mosquito Vacuum 30 to 40 feet away from the location you want to protect The Mosquito Vacuum should be placed in the normal down wind direction towards were mosquitoes live and breed Figure 8 Breeding areas may include standing water marshy wetlands bushes and shady wooded areas Mosquitoes will be lured to the Mosquito Vacuum and be captured before coming into contact with you and your family 1 Determine a suitable place with level ground approximately 30 40 feet away from the area you want to protect 2 Position at least 5 feet from foliage bushes flowerbeds tree line marshbed etc 3 It is recommended the Mosquito Vacuum be place in the shade mosquitoes avoid sunlight 4 Do not place the Mosquito Vacuum directly above a water source sprinklers hoses etc 5 Make sure AC extension cord if used or low voltage extension cord provided with unit are placed in such a manner that they are away from any human or animal activity and cannot be run over with a lawn mower or other such outdoor equipment e Figure 6 2 Figure 7 MOSQUITO VACUUM PLACEMENT CT100 OM qx 2 9 07 2 19 PM Page 7 i OPERATIONAL INSTRUCTIONS Once you start your Stinger Mosquito Vacuum it will begin working immediately luring and trapping mosquitoes but it is recommended to run the Mosquito Vacuum continuously in season to interrupt breeding cycles and reduce mosquito populations A
12. ed these precautions as they are essential when using propane Model No CT100 Coverage 1 acre Input Power 120 VAC 60Hz Output Power 12 VAC 0 8A Use of any other power pack may result in damage and or injury Type of gas used Propane Cylinder Pressure 100 110 psi Minimum Gas Supply Pressure 11 0 in WC Input rating 650Btu Hr Minimum Clearance When in use 5 feet to walls foliage or overhead material Use For outdoor use only in only well ventilated areas Only those persons who can understand and follow these instructions should operate or service this equipment If you need assistance contact our Consumer Relations Department at 1 800 477 0457 2 4 CT100 OM qx 2 9 07 2 19 PM Page 3 c GENERAL SAFETY INSTRUCTIONS 1 WARNING Read this instruction manual before unpacking and operating the Stinger Mosquito Vacuum and retain for future reference 2 WARNING Only use an outdoor extension cord having a 2 prong plug and receptacle that accepts the Stinger Mosquito Vacuum s plug The trap has a 2 conductor cord and a 2 prong grounding type plug to fit a properly GFCI protected grounded outlet 3 WARNING The electrical rating of the extension cord must be greater than or equal to the electrical rating of the Mosquito Vacuum 120 Volt 0 8 Amp Use an extension cord with 16 gauge or thicker wire and that has a label stating it is suitable for outdoor use 4 WARNING Do not abuse any electrical cord Never yank it to disconnect
13. from the receptacle Keep all cords away from heat flammable substances and sharp objects Replace damaged cords 5 WARNING The connection between the Mosquito Vacuum and the extension cord must always remain dry and kept off of the ground 6 WARNING Disconnect the Mosquito Vacuum from the power supply when not in use changing propane tanks before servicing and or cleaning 7 WARNING Do not insert foreign objects into this product 8 WARNING To avoid electric shock DO NOT clean the Mosquito Vacuum by spraying water or by immersing any Mosquito Vacuum part in water 9 WARNING All repairs to the Mosquito Vacuum must be performed only by qualified service personnel 10 WARNING Young children should be carefully supervised when they are in the area of the Mosquito Vacuum 11 WARNING Clothing or other flammable materials should not be hung from or placed on or near the Mosquito Vacuum 12 WARNING Any guard or other protective device removed for servicing the Mosquito Vacuum must be replaced prior to operating 13 WARNING A maximum of a 20 Ib LP Gas cylinder shall be used with the Mosquito Vacuum 14 WARNING Use standard 20 pound LP gas cylinder with a shutoff valve terminating in an LP gas supply cylinder valve outlet specified for Connection No 791 in the Standard for Compressed Gas Cylinder Valve Outlet and Inlet Connections ANSI CGA V 1 latest edition Any standard propane tank manufactured in the USA after 1999 15 WARN
14. gas valve on the propane tank by Figure 19 turning it clockwise amp 2 Press POWER hold 3 seconds until GREEN indicator light blinks Figure 19 This puts the unit in a cool down mode which lasts approximately 2 minutes When the POWER light goes out and the fan shuts down the Mosquito Vacuum is OFF 3 Disconnect low voltage extension cord from power supply while unit is not in use MAINTENANCE 1 Check and clean the Bug Basket on a regular Figure 20 basis The CHECK BUG BASKET indicator light will light RED if the Bug Basket is full removed or installed improperly Figure 20 See REMOVE CLEAN BUG BASKET 2 Refill propane tank every 21 days or as needed The CHECK PROPANE i indicator light will light RED when propane needs to be refilled Figure 21 Be sure POWER is off and unit is unplugged before changing Figure 21 propane tanks 3 Replace the NOsquito by Stinger 2 in 1 Power Bait lure every 60 days The REPLACE LURE indicator light will light YELLOW when the lure needs to be refilled 4 Clean the Mosquito Vacuum s outside surfaces with a mild detergent and a damp cloth DO NOT spray with or immerse any part in water 5 Route the power cord in the safest possible manner to avoid personal injury FOR BEST RESULTS e Position the Stinger Mosquito Vacuum in optimal mosquito breeding area move if necessary to follow change breeding sites e Run the Mosquito Vacuum early and cont
15. inuously in season to interrupt breeding cycles and reduce mosquito populations e The Mosquito Vacuum will run in the rain e f there is an interruption of power restart the Mosquito Vacuum if necessary e Do not move the Mosquito Vacuum with propane tank attached e Empty Bug Basket as needed e Replace NOsquito by Stinger 2 in 1 Power Bait every 30 days 10 a CT100_OM qx 2 9 07 2 19 PM Page 11 g ABOUT MOSQUITOES Approximately 3 000 species of mosquitoes have been identified worldwide with approximately 170 species found in the United States They live and breed near water and thrive in areas with low lying foliage They are most active in the early morning at dusk and in into the evening Some mosquitoes are daytime feeders and are especially active in shady areas and on cloudy days Geography and weather conditions affect mosquito populations and activity Only female mosquitoes bite She hunts for a blood as protein to grow her eggs She is lured to a blood meal by sensing body warmth CO2 from breathing bodily chemicals movement and visual cues such as size color and contrast A single female mosquito may lay thousands of eggs so attracting capturing and killing female mosquitoes with your Stinger Mosquito Vacuum can interrupt breeding cycles and greatly reduce mosquito populations in your yard ACCESSORIES REPLACEMENT PARTS We offer a full line of accesso
16. llow 3 4 weeks to see drastically reduced populations of mosquitoes in your yard 1 2 Place Mosquito Vacuum in optimal location See previous MOSQUITO VACUUM PLACEMENT Plug in Unit Plug the low voltage power connector end of the power supply into the underside of the Vacuum Head located behind the Right Pedestal Upright Figure 9 Attach Unit to Power Supply Plug the power supply into approved 120V GFCI receptacle Figure 10 and position cord such that it will not interfere with outdoor activities If using an approved outdoor extension cord not provided plug the power supply into approved outdoor extension cord plug extension cord into approved 120V GFCI receptacle and position extension cord such that it will not interfere with outdoor activities Turn on Propane Slowly turn propane tank on to the full open position turn valve counter clockwise 4 Check for gas leaks by wiping non ammonia soapy water on the connector and looking for any signs of small bubbles forming Start Mosquito Vacuum This unit has child secure controls Press and hold POWER for 3 seconds to start the unit The fan will go on and POWER indicator light will blink GREEN in warm up mode until it reaches operating temperature approximately 5 minutes Figure 10 When POWER O indicator light is steady GREEN the Mosquito Vacuum is ready to lure and trap mosquitoes If unit fails to light it will cycle through the start up mode two ad
17. ng garage or any other enclosed area 22 CAUTION The pressure regulator and hose assembly supplied with the Mosquito Vacuum must be used for connection to the LP Gas cylinder Replacement pressure regulators and hose assemblies must be provided by Kaz Inc 3 a CT100 OM qx 2 9 07 2 19 PM Page 4 c PROPANE USE SAFETY WARNINGS DANGER Failure to adequately comply with all the safety precautions and detailed instructions provided with the Stinger Mosquito Vacuum can result in death serious bodily injury and property loss or damage resulting from the hazards of fire explosion burn asphyxiation and or carbon monoxide poisoning WARNING Due to the use of propane combustion by products produced when using this product contain certain chemicals known to the State of California to cause cancer birth defects or reproductive harm WARNING The Mosquito Vacuum is fueled by propane gas which is invisible odorless and highly flammable An odorant is normally added by the manufacturer which has a rotten egg smell to it This additive can fade over time so leaking gas is not always detectable by smell alone Propane gas is heavier than air and leaking propane will sink to the lowest possible level It can be ignited by a spark or flame of any kind and from several feet away from a leak Keep the Mosquito Vacuum clear and free from combustible materials gasoline and other flammable vapors and liquids The Trap is not to be used in l
18. ocations where flammable vapor or explosive dust is likely to exist CAUTION The gas pressure regulator provided with the Mosquito Vacuum must be used This regulator is set for an outlet pressure of 11 0 in Water Column The minimum inlet gas supply pressure is 11 WC from regulator PARTS LIST Base Left Upright Pedestal Right Upright Pedestal Left Foot Right Foot Vacuum Head with regulator amp Hose Attached 7 Lure Chamber 8 Extra Lure Storage 9 User Control Panel 10 Troubleshooting Panel 11 Bug Basket 12 12 Volt AC Adaptor with 30 cord attached to Vacuum Head 13 NOsquito by Stinger 2 in 1 Power Bait 14 Hand hold for easy carrying 15 Propane Tank not included User Control Panel OS ee OM om CT100_OM qx 2 9 07 2 19 PM Page 5 ASSEMBLY INSTRUCTIONS The Stinger Mosquito Vacuum is designed to be assembled with NO tools For additional questions on assembly please contact our Consumer Relations Department at 800 477 0457 1 Attach Feet Place Base on level ground Insert Left Foot A and Right Foot B into base Figure 1 2 Attach Upright Pedestals Insert Left Upright Pedestal and Right Upright Pedestal onto corresponding posts on base The ends with U cutouts should be at the top Push down to secure Figure 2 3 Attach the Vacuum Head Align the left and right posts of the Vacuum Head Assembly into the Left and
19. ries to make the Stinger Mosquito Vacuum more convenient Please visit our website at www StingerProducts com for more information PART DESCRIPTION NCL2 NOsquito by Singer 2 in 1 Power Bait CTC1 NOsquito Tank Cover CTLC Lure Chamber CTBB Bug Basket CTXL Extra Lure Tray Kaz also manufactures other devices made for indoor and outdoor pest and insect control Please visit www kaz com or call consumer relations for more information about these devices To order accessories Telephone Call 800 477 0457 with your Visa MasterCard or Discover Online Visit www kaz com with your Visa MasterCard or Discover Fax 508 481 0509 Include part number quantity shipping information telephone number Visa MasterCard or Discover number expiration date and name on the card Mail Send check or money order to Kaz Incorporated Consumer Relations Dept 250 Turnpike Road Southborough MA 01772 Include 6 95 for shipping and handling Add applicable taxes in MA NY and TN Orders are generally received 7 10 days after being placed Please allow 2 6 weeks for mailed in orders CT100_OM qx 2 9 07 2 19 PM Page 12 TROUBLESHOOTING POWER does not go on Press and hold POWER for 3 seconds and wait for GREEN light Be sure all power connections are secure Be sure AC adapter and extension cords are properly plugged in Check fuse and replace if necessary If light does not light call for service o AON CHE