Home

Speed Queen TMB795C User's Manual

image

Contents

1. TMB2148N Oo p CooL Down TimE e8 Figure 15 TMB2149N 24 Published by permission of the copyright owner DO NOT COPY or TRANSMIT 4 Select reversing or nonreversing cylinder rotation setting if applicable an H s TMB2145N Figure 16 5 Press and release START button to start tumbler Display will show minutes remaining before end of cycle START TMB2150N Figure 17 IMPORTANT To stop the tumbler at any time during the cycle OPEN DOOR If the loading door or lint panel door is opened during the cycle the heating system will shut off and the motor will stop To restart the cycle both doors must be closed and the START button must be pressed in 6 When the cycle is complete open door and remove the laundry M414884 EN Electronic OPL Micro Control G Models Through Serial No 0110002231 and H L P S U and Y Models with OM and RM Control Suffixes 1 To use an Automatic Cycle press an ON SELECT pad Select HIGH MEDIUM MED LOW LOW or NO HEAT for items that should not be dried with heat A light to the left of the selected pad lights up To use a Time Dry or Custom Cycle refer to the Programming Manual TMB1483N Figure 18 NOTE Do not press directly on lights or the center of pad For proper selection press on pad slightly to the right of center Refer to Figur
2. TMB811N Models A B C 030 073 gt in ein 13375 in 8 Published by permission of the copyright owner DO NOT COPY or TRANSMIT M414884 EN Gas Connection Locations Installation Operation Supplement TMB812N Models Diameter A B 050 1 2 in NPT 394 mm 1670 mm 15 5 in 65 75 in 075 1 2 in NPT 400 mm 1670 mm 15 75 in 65 75 in M414884 EN Published by permission of the copyright owner DO NOT COPY or TRANSMIT 9 Installation Operation Supplement Electrical Connection Locations A x cy Cee GAS AND STEAM ELECTRIC TMB813N Models A B Gas and Steam fe ee a Electric iG 1 Cae NOTE These figures are approximate dimensions only 10 Published by permission of the copyright owner DO NOT COPY or TRANSMIT M414884 EN Steam Connection Locations Installation Operation Supplement gt A A C M414884 EN Published by permission of the copyright owner DO NOT COPY or TRANSMIT TMB814N Models Diameter A B C D 3 4 in NPT 387 mm 1848 mm 190 mm 1645 mm 050 075 15 25 in 72 75 in 7 5 in 64 75 in 11 Installation Operation Supplement Position and Level the Tumbler To reduce the risk of severe injury clearance of tumbler cabinet from combusti
3. DO NOT COPY or TRANSMIT 19 Installation Operation Supplement Q a 5S CNO lt 5 TMB2014N NOTE Refer to Table 2 for sizing of steam lines Piping must also be sized accordingly for length of runs and number of elbows 1 Supply 8 457 mm 18 in Drop 2 305 mm 12 in Riser 9 Solenoid Valve Supplied with machine 3 Shut Off Valve 10 Steam Bonnet 4 Condensate Return Line from Supply Line 11 Flexible Line 5 Return 12 Union 6 Check Valve 13 Trap with Built In Strainer 7 Vacuum Breaker Optional Figure 3 Steam Pressure bar PSI Minimum Pipe Diameter Steam Trap Size Pounds Condensate Hour 5 3 6 9 80 100 3 4 in NPT 160 Based on 100 PSI Table 2 20 Published by permission of the copyright owner DO NOT COPY or TRANSMIT M414884 EN Installation Operation Supplement Operation ALS Ware To reduce the risk of fire e DO NOT DRY articles containing foam rubber or similarly textured rubberlike materials e DO NOT DRY plastics anything containing wax or chemicals such as mops and cleaning cloths or anything dry cleaned at home with a dry cleaning solvent e DO NOT TUMBLE fiberglass curtains and draperies unless the label says it can be done If they are dried wipe out the cylinder with a damp cloth to remove particles of fiberglass W076 To reduce the risk of serious injury allow cylinder to stop before cleaning lint screen Emergency Stop Butt
4. EE LV LT L P Gas B P 30 No Governor 050 2 1 5 M401003 SI SK 075 2 0 3 M400999 Natural Gas E 20 8 9 050 3 7 2 M401000 075 3 6 3 M401014 LL 25 12 6 050 3 7 2 M401000 pex 075 3 6 3 M401014 L P Gas B P 30 No Governor 050 2 1 2 M401003 075 2 0 3 M400999 B P 50 28 5 050 2 1 2 M401003 075 2 0 3 M400999 Natural Gas L 25 12 6 050 3 7 2 M401000 NE 075 3 6 3 M401014 L P Gas B P 30 No Governor 050 2 1 2 M401003 075 2 0 3 M400999 Natural Gas E 20 25 No Governor 050 3 0 2 M401017 075 2 9 3 N A BE FR L P Gas 28 37 No Governor 050 2 1 2 M401003 075 2 0 3 M400999 Natural Gas H 20 8 9 050 3 7 2 M401000 GBAE PT 075 3 6 3 M401014 ES AT GR LU CH L P Gas 28 37 No Governor 050 2 1 2 M401003 075 2 0 3 M400999 Natural Gas H 20 8 9 050 3 7 2 M401000 pon 075 3 6 3 M401014 L P Gas B P 50 28 5 050 2 1 2 M401003 075 2 0 3 M400999 L P Gas B P 30 No Governor 050 2 1 2 M401003 CYAS MT 075 2 0 3 M400999 Table 1 M414884 EN Published by permission of the copyright owner DO NOT COPY or TRANSMIT 15 Installation Operation Supplement Burner Supply P Burner Country Gas Type Group Pressure Orifice Capacity Diameter Quantity Orifice Code Pressure Model mm mbar Part No mbar Natural Gas H 25 8 9 050 3 7 2 M401000 HU 075 3 6 3 M401014 L P Gas B P 30 No Governor 050 2 1 2 M401003 075 2 0 3 M400999 Natural Gas H 20 8 9 050 3 7 2 M401000 PL 075 3 6 3 M401014 L P Gas 3P 37 No Gover
5. European Gas eerren EE E oe ere ease eed Levees 14 General Information orei en i tenet seis naeel A 15 Exhaust Requirement ccc ceeceseesseeescesseceeeseeeseecsaeceeesseeeseeeaeeenaes 17 Make Up Alt scs s2i 3 Sai as Set hese te alee eis 17 NONUN Ges sti retrial ee rene E ROE EE 17 Electrical Requirements eenia a 18 Grounding Instructions sseeeeseseeeeeeeeeestesesresserrrsresresersreserrrsseesesees 18 Steam Requirements eeii eaa eaa i aa ai Eata 19 Thermal Oil Prep 2 i eailwetien ann e a iaeaea ele 19 Operation ronaned eer ee ae eh 21 Emergency Stop Button eeceeeeseeeseceseeseeeseeeseecaecneeseeeeseeeaeeenaes 21 Operating Instructions 0 0 eeececscceeseceeececeececeeeeaecesaeceeaeceeaeeceeeeeeeees 21 Step 1 Clean Lint Screen Compartment 00 eee eeeeseceseeeeeneeeneee 21 Step 2 Load Laundry vcs cc Se niine sessed dice latent 21 Step 3 Determine Control Type and Temperature Setting 21 Step 4 Remove Laundry 00 0 eee eeeesceeseceeeeseeeseeenseceeeeseeeseeeaeeenaes 21 Control INStructions 4 ie siieis shes isin aeie e eii iai aa i 22 Electromechanical Coin Control 0 0 eeseeeeceeeceseeeseeeaecneeesesenes 22 Manual Timer Control oe eeeesceeeeeeeeseecnseceseeeeceseeeseeeaaecnaeeeseaes 23 Dual Digital Timer Control ee eeeeeeescesseeseeeeeeeseeesaesnaeeneeeaes 24 Electronic OPL Micro Control cee eeeeseceseceseeseeeeeeenseceaeceaeeseeeees 25 Single Drop Control cc3 cescits cehieiess ie a
6. tumbler before servicing e Close gas shut off valve to gas tumbler before servicing e Close steam valve to steam tumbler before servicing Never start the tumbler with any guards panels removed e Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the tumbler is properly grounded W002 M414884 EN Installation Operation Supplement General Information Models are built in two different configurations This information is to be used when installing gas e Natural Gas regulated governor tumblers in countries and or on gases different than the machine s factory configuration Tumblers are supplied from the factory for operation on Natural Gas or L P Gas in the countries of GB IE PT ES IT GR LU CH To install machines in any other country or on any other gas requires some level of modification e Liquefied Petroleum L P Gas not regulated no governor Machines configured for Natural Gas regulator governor may be converted to L P Gas not regulated no governor with block open kit Part No M400763 Serial plates are configured for GB IE PT ES IT GR LU CH Country Supply Oee Capacity Diameter Burner Code Gas Type Group Pressure Pressure Model mm Quantity Orifice mbar Part No mbar DK NO Natural Gas H 20 8 9 050 3 7 2 M401000 SE FI CZ 075 3 6 3 M401014
7. 1 Boiler Horsepower Btu hr 177 500 210 300 6 Published by permission of the copyright owner DO NOT COPY or TRANSMIT M414884 EN Cabinet Dimensions Installation Operation Supplement TMB2210N Models C D E F G 050 2K eK Gas and 781 mm 730 mm 717 mm 860mm 1194mm 1946mm 981 mm 838 mm 749 mm Electric 30 75 in 28 75 in 28 25 in 33 87 in 47 in 76 625 in 38 625 in 83in 29 5 in 050 781 mm 730 mm 717 mm 860 mm 1194 mm 2032 mm 981 mm 838 mm 749 mm Steam 30 75 in 28 75 in 28 25 in 33 87 in 47 in 80 in 38 625 in 33 in 29 5 in ae g 781mm 730mm 717mm 860mm 1346mm 1946mm 981mm 838mm 902mm Electric 30 75 in 28 75 in 28 25 in 33 87 in 53 in 76 625 in 38 625 in 33in 35 5 in 075 781 mm 730 mm 717 mm 860 mm 1346mm 2032 mm 981 mm 838 mm 902 mm Steam 30 75 in 28 75 in 28 25 in 33 87 in 53 in 80 in 38 625 in 33 in 35 5 in H S and U models prior to Serial No 0308001307 and all other models H S and U models after Serial No 0308001307 M414884 EN Published by permission of the copyright owner DO NOT COPY or TRANSMIT Installation Operation Supplement Horizontal Exhaust Outlet Locations a gt
8. air to the tumbler s increase the area of the ductwork by 25 to compensate for any restriction in air movement M414884 EN Installation Operation Supplement Venting Proper sized exhaust ducts are essential for proper operation All elbows should be sweep type Exhaust ducts must be assembled so the interior surfaces are smooth to prevent the accumulation of lint DO NOT use plastic or thin foil flexible ducts Use exhaust ducts made of sheet metal or other noncombustible material Use duct tape or pop rivets on all seams and joints Verify that old ducts are thoroughly cleaned out before installing new tumbler NOTE The ducts must be equivalent in strength and corrosion resistance to ducts made of galvanized sheet steel not less than 0 495 mm 0 0195 inches thick IMPORTANT For best performance provide an individual exhaust duct for each tumbler Do not install a hot water heater in a room containing tumblers It is better to have the water heater in a separate room with a separate air inlet NOTE This manual is only a supplement Refer to installation operation manual for full instructions Published by permission of the copyright owner DO NOT COPY or TRANSMIT 17 Installation Operation Supplement Electrical Requirements Al wanna To reduce the risk of electric shock fire explosion serious injury or death Disconnect electric power to the tumbler before servicing e Close gas shut off valve to
9. daily 4 Published by permission of the copyright owner DO NOT COPY or TRANSMIT M414884 EN 22 23 24 25 26 27 M414884 EN Install this tumbler according to the INSTALLATION INSTRUCTIONS All connections for electrical power grounding and gas supply must comply with local codes and be made by licensed personnel when required Remove laundry immediately after tumbler stops Always read and follow manufacturer s instructions on packages of laundry and cleaning aids Heed all warnings or precautions To reduce the risk of poisoning or chemical burns keep them out of reach of children at all times preferably in a locked cabinet Do not tumble fiberglass curtains and draperies unless the label says it can be done If they are dried wipe out the cylinder with a damp cloth to remove particles of fiberglass Always follow the fabric care instructions supplied by the garment manufacturer Never operate the tumbler with any guards and or panels removed 28 30 31 Installation Operation Supplement DO NOT operate the tumbler if it is smoking grinding has missing or broken parts DO NOT bypass any safety devices Solvent vapors from dry cleaning machines create acids when drawn through the heater of the drying unit These acids are corrosive to the tumbler as well as to the laundry load being dried Be sure make up air is free of solvent vapors Failure to install maintain and or
10. determine proper temperature setting IMPORTANT Always follow the fabric care instructions supplied by the garment manufacturer Step 4 Remove Laundry When the cycle is complete open door and remove the laundry M414884 EN Published by permission of the copyright owner DO NOT COPY or TRANSMIT 21 Installation Operation Supplement Control Instructions Electromechanical Coin Control CD CX and CY Control Suffixes 1 Set the TEMPERATURE selector at HIGH or LOW or anywhere between these settings TEMPERATURE LOW TMB1487N Figure 5 2 Coin Drop Models Insert the coin s in the coin slot turn the knob to the right and release it INSERT QUARTER J TURN KNOB 25 TMB1489N Figure 6 22 Published by permission of the copyright owner DO NOT COPY or TRANSMIT 3 Press the PUSH TO START button and hold it for approximately three 3 seconds PUSH TO O H START O TMB1488N Figure 7 IMPORTANT If the loading door or lint panel door is opened during the cycle the heating system will shut off and the motor will stop However the timer will continue to run To restart the cycle both doors must be closed and the PUSH TO START button must be pressed 4 When the cycle is complete open door and remove the laundry M414884 EN Manual Timer Control MT and RT Control Suffixes 1 Set the HEAT DRYING timer for the number of minutes from 0 60 desir
11. gas tumbler before servicing e Close steam valve to steam tumbler before servicing Never start the tumbler with any guards panels removed Whenever ground wires are removed during servicing these ground wires must be reconnected to ensure that the tumbler is properly grounded W002 To reduce the risk of fire and electric shock check with a qualified serviceman for proper grounding procedures Improper connection of the equipment grounding conductor may result in a risk of electric shock W068 To reduce the risk of fire and electric shock if electrical supply is coming from a three phase service DO NOT connect a High Leg or Stinger Leg to a single phase machine On a three phase machine if there is a High Leg or Stinger Leg it should be connected to L3 W069 Grounding Instructions NOTE To ensure protection against shock this tumbler MUST be electrically grounded in accordance with the local codes or in the absence of local codes with the latest edition of the National Electrical Code ANSI NFPA No 70 In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for electric current This tumbler must be connected to a grounded metal permanent wiring system or an equipment grounding conductor must be run with the circuit conductors and connected to the appropriate ground location 18 Published by permission of the c
12. hoses are available as optional equipment at extra cost if the hoses supplied with the tumbler are not long enough for installation Order hoses as follows Part No 20617 Inlet hose 2 44 m 8 feet Part No 20618 Inlet hose 3 05 m 10 feet Published by permission of the copyright owner DO NOT COPY or TRANSMIT 13 Installation Operation Supplement Electrical Requirements Electrical power must be provided to tumbler at all times The fire suppression system will be inoperative if the main electrical power supply is disconnected W690 No independent external power source or supply connection is necessary Power to operate the 24 Volt fire suppression system is from the rear junction contactor box Auxiliary Alarm During tumbler installation you have the option to connect a separate alarm system to this auxiliary output Use of the auxiliary output is not required for the fire suppression system to operate but may be used for additional protection NOTE The auxiliary output is activated during fire suppression system maintenance test sequence Consider this fact prior to your system test every three months Example If the external system uses the auxiliary output to call the fire department inform the fire department before and after the fire suppression system maintenance test Gas Requirements Natural Gas and Liquefied Petroleum To reduce the risk of fire or explosion DO NOT CONNECT THE GAS LINE
13. of 827 kPa 120 psi of pressure at all times Flowrate must be no less than but approximately 57 liters 15 gallons per minute NOTE Water pressure under 138 kPa 20 pounds per square inch will cause low flow and water leakage at water solenoid valve IMPORTANT Temperature of the water supply must be kept between 4 4 and 48 9 C 40 and 120 F If water in the supply line or water solenoid valve freezes the fire suppression system will not operate IMPORTANT If temperature sensors inside the tumbler register a temperature below 4 4 C 40 F the fire suppression system control will lock out This feature protects against operation of the tumbler with a possible frozen water supply Only when the temperature sensors register a temperature above 4 4 C 40 F will the machine reset for operation IMPORTANT Flexible supply line coupling must be used Solenoid valve failure due to hard plumbing connections will void the warranty It is recommended that a filter or strainer be installed in the water supply line M414884 EN Installation Operation Supplement Water Connections TMB2008N Lock Hose Couplings Y Valve Inlet Hoses Opening for Auxiliary Alarm Cable QA OND Figure 2 IMPORTANT Thread hose couplings onto valve connections finger tight then turn 1 4 turn with pliers Do not cross thread or overtighten couplings IMPORTANT Replace all hoses every five years NOTE Longer inlet
14. of this product could expose you to substances in the fuel or from fuel 2 Refer to the GROUNDING INSTRUCTIONS combustion which can cause death or serious for the proper grounding of the tumbler illness and which are known to the State of W359 3 Do not dry articles that have been previously California to cause cancer birth defects or other cleaned in washed in soaked in or spotted with reproductive harm gasoline dry cleaning solvents or other 16 Tumbler will not operate with the loading door flammable or explosive substances as they give ae open DO NOT bypass the door safety switch to off vapors that could ignite or explode permit the tumbler to operate with the door open 4 Do not allow children to play on or in the The tumbler will stop tumbling when the door is tumbler This appliance is not intended for use by opened Do not use the tumbler if it does not stop young children or infirm persons without tumbling when the door is opened or starts supervision Young children should be tumbling without pressing or turning the START supervised to ensure that they do not play with mechanism Remove the tumbler from use and the appliance call for service 5 Before the tumbler is removed from service or 17 Tumbler will not operate with lint panel open discarded remove the door to the drying DO NOT bypass lint panel safety switch to compartment and the door to the lint permit the tumbler to operate with the lint panel com
15. operate this machine according to the manufacturer s instructions may result in conditions which can produce bodily injury and or property damage To reduce the risk of serious injury install lockable door s to prevent public access to rear of tumblers W055 Published by permission of the copyright owner DO NOT COPY or TRANSMIT 5 Installation Operation Supplement Installation Specifications and Dimensions Specifications 50 Pound 75 Pound Noise level measured during operation at 63 dBA 69 dBA operator position of 1 meter 3 3 feet in front of machine and 1 6 meters 5 2 feet from floor Net Weight approximate 247 279 kg Ibs 545 615 Cylinder Size 940 x 762 940 x 914 mm in 37 x 30 37 x 36 Cylinder Capacity dry weight 22 7 34 kg Ibs 50 75 Air Outlet Diameter 203 203 mm in 8 8 Maximum Static Back Pressure 1 3 1 3 mbar inches W C 0 5 0 5 Maxi Airflow 354 Gas Steam 50 Hz 354 750 h sec CF M ow 150 Gas Steam 60 Hz 434 920 Aa Electric 354 750 Motor Horsepower Nonreversing 1 2 3 4 Reversing Fan 1 3 1 3 Cylinder 13 13 Gas Models Gas Connection 1 2 in NPT 1 2 in NPT Gas Burner Rating 126 6 174 1 Mj hr Btu hr 120 000 165 000 Electric Models Heating Element Rating 21 kW 240 V 50 Hertz 30kW Kilowatts kW 30 kW other voltages Steam Models Steam Connection 3 4 in NPT 3 4 in NPT Steam Coil Rating 5 1 6
16. restart the tumbler CLOSE door and press START button 4 When the cycle is complete open door and remove the laundry Installation Operation Supplement MDC Coin and Card Control BC BG BL BU BX and BY Control Suffixes 1 Select temperature by pressing the appropriate temperature pad TMB1962N Figure 30 2 Insert the coin s in the coin slot or the card into the opening Q TMB1492N TMB1963N Figure 31 3 Press START pad to start tumbler D Figure 32 TMB1491N IMPORTANT To stop the tumbler at any time during the cycle OPEN DOOR To restart the tumbler CLOSE door and press START pad 4 When the cycle is complete open door and remove the laundry M414884 EN Published by permission of the copyright owner DO NOT COPY or TRANSMIT 27 Installation Operation Supplement Ignition Control Operation Diagnostic LED DGN LED Error Codes The Diagnostic LED or DGN LED is located by the power connector on the ignition control Refer to Figure 33 The Diagnostic LED will indicate the status of the ignition control Refer to Table 3 LED Color Description Orange Yellow Initialization Green Standby Normal Operation Red Fault Indication Code Table 3 The Diagnostic LED will flash error codes one half second on and one half second off Error codes are separated by a one second pause before the code is repea
17. 4 M414884 EN Published by permission of the copyright owner DO NOT COPY or TRANSMIT 29
18. Drying Tumblers 50 Pound Capacity 75 Pound Capacity Refer to Page 3 for Model Identification CE TMB795C Keep These Instructions for Future Reference If this machine changes ownership this manual must accompany machine Part No M414884R10 February 2008 yuswa jddns uoneIsado uoneesu m Installation must conform with local codes Al wamne FOR YOUR SAFETY the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death W033 Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not try to light any appliance Do not touch any electrical switch do not use any phone in your building Clear the room building or area of all occupants Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas supplier W052 FOR YOUR SAFETY Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance W053 IMPORTANT Information must be obtained from a local gas supplier on instructions to be followed if the user smells gas Thes
19. TEMPERATUR m 000 y TMB2201N Figure 23 2 Select REVERSING or NONREVERSING cylinder rotation setting REV CYLINDER TMB2206N Figure 24 26 Published by permission of the copyright owner DO NOT COPY or TRANSMIT 3 Press START pad to start tumbler START Figure 25 TMB2202N NOTE All pads can be pressed in any sequence without damaging control or tumbler To stop the tumbler at any time open the door or press STOP V STOP Figure 26 TMB2203N NOTE The window display will flash Press STOP twice within 3 seconds to end the cycle and reset the control to idle status To restart the tumbler CLOSE door and press START pad IMPORTANT If the loading door or lint panel door is opened during the cycle the heating system will shut off and the motor will stop To restart the cycle both doors must be closed and the PUSH TO START button must be pressed in 4 When the cycle is complete open door and remove the laundry M414884 EN Single Drop Control SD and SX Control Suffixes 1 Select HIGH MED LOW or NO HEAT by turning the temperature knob TMB2147N Figure 27 2 Insert the coin s in the coin slot Q tt Figure 28 3 Press START button to start tumbler TMB1492N E START TMB2150N Figure 29 IMPORTANT To stop the tumbler at any time during the cycle OPEN DOOR To
20. TO THE TUMBLER IF THE GAS SERVICE IS NOT THE SAME AS THAT SPECIFIED ON THE TUMBLER SERIAL PLATE It will first be necessary to convert the gas burner orifice and gas valve Appropriate conversion kits are available IMPORTANT Any product revisions or conversions must be made by the Manufacturer s Authorized Dealers Distributors or local service personnel 14 Published by permission of the copyright owner DO NOT COPY or TRANSMIT IMPORTANT The tumbler must be isolated from the gas supply piping system by closing its individual manual shut off valve during any pressure testing of the gas supply piping system at test pressure equal to or less than 3 45 kPa 34 5 mbar 0 5 psi IMPORTANT The tumbler and its manually operated appliance gas valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures in excess of 3 45 kPa 34 5 mbar 0 5 psi IMPORTANT The installation must comply with local codes WARNING To reduce the risk of fire or explosion if the tumbler is to be connected to Liquefied Petroleum L P gas a vent to the outdoors must be provided in the room where the tumbler is installed W062 NOTE This manual is only a supplement Refer to installation operation manual for full instructions European Gas To reduce the risk of electric shock fire explosion serious injury or death e Disconnect electric power to the
21. ble construction must conform to the minimum clearances A To eeg w A IC ae lt r 7 8 TMB2131N NOTE Shaded areas indicate adjacent structure 1 13 mm 0 5 in recommended between machines for removal or installation 2 Allow 51 102 mm 2 4 in opening at top of machine to aid in removal or installation A removable trim piece may be used to conceal the opening zero clearance allowed for trim 102 mm 4 in maximum header thickness 305 mm 12 in minimum clearance permitted for remainder Guard Provision for make up air 610 mm 24 in minimum 914 mm 36 in recommended for maintenance purposes 6 mm 0 25 in recommended for removal or installation purposes zero clearance allowed ONDA AR amp Figure 1 NOTE This manual is only a supplement Refer to installation operation manual for full instructions 12 Published by permission of the copyright owner DO NOT COPY or TRANSMIT M414884 EN Fire Suppression System G H K S and U Models Only Water Requirements IMPORTANT Water must be supplied to the fire suppression system or the fire suppression system will not operate as intended Connection point to the electric water solenoid valve is a 19 mm 3 4 inch hose The fire suppression system equipped tumbler must be supplied with a minimum water pipe size of 12 7 mm 1 2 inch and be provided with a minimum of 138 kPa 20 psi and a maximum
22. bler Install shut off valve union check valve and bypass trap at end of line If the system has a gravity return to boiler omit trap e Insulate steam supply and return lines for safety of operator and safety while servicing tumbler e Keep tumbler in good working condition Repair or replace any worn or defective parts All system components must have a 8 6 bar 125 psig working pressure Shut off valves must be installed upstream of the steam solenoid valve and downstream of each steam trap so components can be isolated for maintenance or emergency purposes All components solenoid valve traps must be supported to minimize loads on the tumbler steam coil connections w701 NOTE This manual is only a supplement Refer to installation operation manual for full instructions M414884 EN Installation Operation Supplement Thermal Oil Prep It is the responsibility of the customer to install appropriate coil and heating system for thermal oil prep models Alliance Laundry Systems LLC is not responsible for the performance or safety of the customer installed thermal oil system To ensure proper operation refer to the Specifications and Dimensions section for the BTU input of equivalent steam models Thermal oil systems that do not deliver appropriate BTUs will dry slower For solenoid valve wiring connections refer to the Wiring Diagram supplied with tumbler Published by permission of the copyright owner
23. e 19 GES TMB806N Figure 19 2 Select REVERSING or NONREVERSING cylinder rotation setting O REVERSING a S TMB1486N Figure 20 M414884 EN Installation Operation Supplement 3 Press START pad to start tumbler KO Figure 21 TMB1485N NOTE All pads can be pressed in any sequence without damaging control or tumbler To stop the tumbler at any time open the door or press STOP RESET STOP RESET Figure 22 TMB1484N NOTE The window display will flash Press STOP RESET twice within three seconds to end the cycle and reset the control to idle status To restart the tumbler CLOSE door and press START pad IMPORTANT If the loading door or lint panel door is opened during the cycle the heating system will shut off and the motor will stop To restart the cycle both doors must be closed and START pad must be pressed 4 When the cycle is complete open door and remove the laundry Published by permission of the copyright owner DO NOT COPY or TRANSMIT 25 Installation Operation Supplement G Models Starting Serial No O707xxxxx and K Models with OM and RM Control Suffixes 1 To use an Automatic Cycle press a TEMPERATURE pad Select HIGH MED LOW DELICATE or NO HEAT for items that should not be dried with heat A light to the left of the selected pad lights up To use a Time Dry or Custom Cycle refer to the Programming Manual
24. e O f TAVERN CERO NES cS accrue lean ei caacea ase enc ncrcesd tal eesacnsealon Rasatnineteiainctatd teat Model Identification sonen erne r dn nas Con ten ts Waring Dia stam cs Hien edi deniar ei e e eaa glia lin des 3 Serial Plate Locations is ces esate ies etessneren EE EA desea 3 Safety Informationen he hase a en a 4 Important Safety Instructions 2 0 0 ees esseeseceseceeeeeeeeseceseceaeeeeeeeneenaees 4 Installation ive ceiecieatiea git aaah tea ele aes 6 Specifications and Dimensions ceeceeeeseeeseceeceseeseeeeeeeseeeaaeeneeees 6 Cabinet Dimensions i1 i205 dire diss aileeti eget dete oes 7 Horizontal Exhaust Outlet Locations ccceccccesseceneeceeeeeeeeeesees 8 Gas Connection Locations i ceeceeeeseeeseceseceteeseeeeaeeaecsseceaeeeeeeses 9 Electrical Connection Locations cecsceesseeseeceeseceeeceeaeeceaeeeees 10 Steam Connection Locations ccceescesceseeeseeeseceeeeeeeeeeeaeenaees 11 Position and Level the Tumblet ccccceecceesceeeseceeseecenaeceeaeeceaeeeees 12 Fire Suppression System eeeeseeecssecsseeseceseceseeeseecsecseeeeseseaeeeaaeenaes 13 Water Requirements scine rire ia aa aas 13 Water Connections idiniin tie e E eit A Ea 13 Electrical Requirements ceire e 14 Auxiliary Alarm js ccccsttssccstsahessetadeenisetersancscste le dectes ieta iien ie it iee 14 Gas Requirements fis a gees Baia OEE EEDEN NESEN SENEE Ean 14 Natural Gas and Liquefied Petroleum 14
25. e instructions must be posted in a prominent location Step by step instructions of the above safety information must be posted in a prominent location near the tumbler for customer use M414884 EN Installation Operation Supplement Al wanno To reduce the risk of fire electric shock serious injury or death to persons when using the tumbler unit follow these basic precautions Read all instructions before using tumbler e DO NOT tamper with controls e DO NOT bypass any safety devices Always follow the fabric care instructions supplied by the garment manufacturer e Remove laundry immediately after the tumbler stops DO NOT reach into tumbler if cylinder is revolving To avoid creating any flammable vapors which may explode ignite or cause corrosive damage DO NOT dry the following materials e Articles that have been cleaned in soaked in washed in or spotted with gasoline dry cleaning solvents or other flammable explosive substances e Plastics or articles containing foam rubber or similarly textured rubberlike materials e Articles that have traces of flammable substances like cooking oil machine oil flammable chemicals or thinner e Articles containing wax or cleaning chemicals e Fiberglass curtains or draperies unless the label says it can be done W440R1 Published by permission of the copyright owner DO NOT COPY or TRANSMIT 1 Installation Operation Supplement Ta b
26. ed TMB2142N Figure 8 2 Set the COOL DOWN COOLING timer for the number of minutes from 0 15 desired TMB2143N Figure 9 3 Set the TEMPERATURE selector at HIGH LOW or anywhere between these settings TEMPERATURE HIGH AN LOW TMB2144N Figure 10 4 Select reversing or nonreversing cylinder rotation setting if applicable Gg Figure 11 TMB2145N Installation Operation Supplement 5 Press the PUSH TO START button in and hold it in for approximately three 3 seconds This starts the tumbler cycle i H TO START Figure 12 IMPORTANT If the loading door or lint panel door is opened during the cycle the heating system will shut off and the motor will stop To restart the cycle both doors must be closed and the PUSH TO START button must be pressed in TMB2146N 6 When the cycle is complete open door and remove the laundry M414884 EN Published by permission of the copyright owner DO NOT COPY or TRANSMIT 23 Installation Operation Supplement Dual Digital Timer Control QT and RQ Control Suffixes 1 Select HIGH MED LOW or NO HEAT by turning the temperature knob TMB2147N Figure 13 2 Set the HEAT TIME for the number of minutes from 0 60 desired S HEAT TIME ea Figure 14 3 Set the COOL DOWN TIME for the number of minutes from 0 15 desired
27. eversing OPL Micro BG basic electronic OPL mode CX prep for coin RQ reversing dual digital timer BL basic electronic central pay CY prep for card RT reversing manual timer BU basic electronic prep card open MT manual timer SD single drop BX basic electronic prep for coin OM OPL Micro SX single drop prep for coin BY basic electronic prep for card QT dual digital timer Wiring Diagram Serial Plate Location The wiring diagram is located in the junction or contactor box 2 FesoaN 1 Serial Plate M414884 EN Published by permission of the copyright owner DO NOT COPY or TRANSMIT 3 Installation Operation Supplement Safety Information Save These Instructions Important Safety Instructions 13 Keep area around the exhaust opening and adjacent surrounding area free from the accumulation of lint dust and dirt 14 The interior of the tumbler and the exhaust duct Hazardous Voltage Can cause shock burn should be cleaned periodically by qualified or cause death Allow machine power to service personnel remain off for two minutes prior to working 15 g If not installed operated and maintained in in and around AC inverter drive p accordance with the manufacturer s instructions or if there is damage to or mishandling of this 1 Read all instructions before using the tumbler product s components use
28. i iat 27 MDC Coin and Card Control oo cece eeceeseeseeseceseceeeensecnseenseeseeeses 27 Ignition Control Operation eee eseeseeseceseceeeeeeeeeseceeeeeeeseeeaeeenaes 28 Disposal OF Umiticcsssclecils cist seiscesseteieabed cares thcaeedstacestaboceess te ascdainsiceaheaseesds 29 Published by permission of the copyright owner All rights reserved No part of the contents of this book may be reproduced or transmitted in any form or by any means without the expressed written consent of the publisher 2 Published by permission of the copyright owner DO NOT COPY or TRANSMIT M414884 EN Installation Operation Supplement Introduction Model Identification Information in this manual is applicable to these models Gas Steam Thermal Oil Electric GUO0S50L LUOSON GU050S LUO50T GU050E GU050N PUOS50L GU050T PU050S HUOS50E HUOS50L PUO50N HU050S PUOS50T KUOS50E 50 Pound HUO50N SU0S50L HUO50T SU050S LUOS50E KUOSOL SU050N KU050S SU050T PUOS0E KUOS50N UUO050L KUO50T UU050S SU050E LUOS50L UU050N LUOS50S UU050T UU050E GUO075L LUO75N GUO075S PUO75S GUO075E GUO075N PUO75L GU075T PUO75T HUO75E HUO75L PUO75N HU075S SU075S KU075E 75 P d HUO75N SU075L HU075T SU075T LUO75E 5 Poun KU075L SU075N KU075S UU075S PU075E KU075N UU075L KUO075T UU075T SU075E LUO75L UU075N LUO75S YUO75S UU075E LUO75T YUO75T YUO75E Includes models with control suffixes BC basic electronic coin CD rotary coin drop RM r
29. nor 050 2 1 2 M401003 075 2 0 3 M400999 Table 1 Burner orifice information at 0 600 meters 0 2000 feet altitude For Natural Gas Group E applications convert using L P N A Part no longer available 16 Published by permission of the copyright owner DO NOT COPY or TRANSMIT xk Gas model and replace burner orifices For L P Gas Group B P with 50 mbar supply pressure convert using Natural Gas model M411334 regulator spring kit and burner orifices M414884 EN Exhaust Requirements AL wanna A drying tumbler produces combustible lint To reduce the risk of fire the tumbler must be exhausted to the outdoors W057 To reduce the risk of fire and accumulation of combustible gases DO NOT exhaust tumbler air into a window well gas vent chimney or enclosed unventilated area such as an attic wall ceiling crawl space under a building or concealed space of a building W059 Make Up Air IMPORTANT Do not obstruct the flow of combustion and ventilation air A tumbler is forced air exhausted and requires provisions for make up air to replace the air exhausted by the tumbler Required Make Up Air Opening to the outside for Each Tumbler Model Opening 050 928 cm 144 in 075 1258 cm 195 in Make up air openings with louvers will restrict airflow The opening must be increased to compensate for area taken up by louvers If it is necessary to duct make up
30. on Operating Instructions All OPL tumblers are factory equipped with an Step 1 Clean Lint Screen Compartment emergency stop button located on the front panel Refer to Figure 4 Remove any accumulated lint from the lint screen and compartment Close panel tightly against tumbler frame and lock panel securely if applicable IMPORTANT Clean lint screen and lint compartment daily Failure to clean the lint screen Pa daily will result in higher than normal temperatures that may damage laundry Step 2 Load Laundry Open loading door and load cylinder with laundry DO TMB1666N NOT OVERLOAD 1 Emergency Stop Button NOTE Overloading causes slow drying and wrinkling Figure 4 Close loading door Tumbler will not operate with the To operate emergency stop button door open a Press red emergency stop button to stop all action Step 3 Determine Control Type and Temperature Setting b To restart machine pull red emergency stop button out and press START pad or button Refer to the various controls in the Control a Instructions section pages 22 27 determine NOTE Activation of the emergency stop button appropriate control and then follow the instructions stops all machine control circuit functions but DOES NOT remove all electrical power from machine The type of fabric being dried will determine the temperature setting Consult the fabric care label or fabric manufacturer to
31. opyright owner DO NOT COPY or TRANSMIT e Metal conduit and or BX cable is not considered ground e Connecting the Neutral from the electrical service box to the tumbler ground screw does not constitute a ground e A dedicated ground conduit wire must be connected between the electrical service box ground bar and the tumbler ground screw To reduce the risk of electrical shock de energize the electrical circuit being connected to the tumbler before making any electrical connections All electrical connections should be made by a qualified electrician Never attempt to connect a live circuit W409 CAUTION Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing W071 All OPL non vend models are factory equipped with an emergency stop button on the front panel NOTE Activation of the emergency stop button stops all machine control circuit functions but DOES NOT remove all electrical power from machine NOTE This manual is only a supplement Refer to installation operation manual for full instructions M414884 EN Steam Requirements Obtain specific steam service pipe sizes from the steam system supplier or a qualified steam fitter e Refer to Figure 3 for proper steam pipe configurations e When tumbler is on the end of a line of equipment extend header at least 1 2 meters 4 feet beyond tum
32. partment open 6 Do not reach into the tumbler if the cylinder is 18 Do not put articles soiled with vegetable or cooking revolving oil in the tumbler as these oils may not be removed during washing Due to the remaining oil the fabric may catch on fire by itself 19 To reduce the risk of fire DO NOT put clothes which have traces of any flammable substances 7 Do not install or store the tumbler where it will be exposed to water and or weather 8 Do not tamper with the controls 9 Do not repair or replace any part of the tumbler such as machine oil flammable chemicals or attempt any servicing unless specifically thinner etc or anything containing wax or recommended in the user maintenance chemicals such as in mops and cleaning cloths or instructions or in published user repair anything dry cleaned at home with dry cleaning instructions that you understand and have the solvent in the tumbler skills to carry out 20 Use the tumbler only for its intended purpose 10 Do not use fabric softeners or products to drying fabrics eliminate static unless recommended by the 21 ALWAYS disconnect and lockout the electrical manufacturer of the fabric softener or product power to the tumbler before servicing 11 To reduce the risk of fire DO NOT DRY plastics Disconnect power by shutting off appropriate or articles containing foam rubber or similarly breaker or fuse textured rubberlike materials 12 Always clean the lint filter
33. ted pie DGN LED status Fault Type 1 Red Ignition Control Internal Failure 2 2 Red Flashes Gas Valve Not Connected 3 3 Red Flashes Ignition Flame Sense Failure 4 4 Red Flashes Reset Switch is Shorted 5 Slow Red and Green Flashes Low Voltage Detection 6 Fast Red and Orange Flashes Ignition Control is in Reset Delay TMB2176N 1 Diagnostic DGN LED Figure 33 28 Published by permission of the copyright owner DO NOT COPY or TRANSMIT M414884 EN This appliance is marked according to the European directive 2002 96 EC on Waste Electrical and Electronic Equipment WEEE This symbol on the product or on its packaging indicates that this product shall not be treated as household waste Refer to Figure 34 Instead it shall be handed over to the applicable collection point for the recycling of electrical and electronic equipment Ensuring this product is disposed of correctly will help prevent potential negative consequences for the environment and human health which could otherwise be caused by inappropriate waste handling of this product The recycling of materials will help to conserve natural resources For more detailed information about recycling of this product please contact the local city office household waste disposal service or the source from which the product was purchased Installation Operation Supplement Disposal of Unit MIX1N Figure 3