1. Front view 1 Keypad Power Accuracy Units amp Volume switches 2 Beeper output Fast solid amp slow audible signal 3 Bubble Vial aids in keeping HL450 level 4 Anti strobe sensor Reduces false indication from strobe lights 5 SuperCell Reception Window 4 0 in 102 mm of height 6 Front LCD Displays elevation settings and status T On grade Mark Aligned with laser center on grade reading EMC Declaration of Conformity This receiver has been tested and found to comply with the limits for a Class B digital device for radio noise for digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Com munication and is pursuant to part 15 of the Federal Communication Commission FCC rules These limits are designed to provide reason able protection against harmful interference in a residential installation This receiver generates radio frequency If it s not used in accordance with the instructions it may cause harmful interference to radio or televi sion reception Such interference can be determined by turning the re ceiver off and on You are encouraged to try eliminating the interference by one or more of the following measures e Reorient or relocate the receiving antenna e Increase the separation between the laser and the receiver For more information consult your dealer or an experience radio television technician CAUTION Changes or modifica
2. Specifications Working Radius Laser dependent Laser Detection Height Numeric Readout Height Accuracy Dead band Fine Medium Calibration Reception Angle Detectable Spectrum Beeper Volumes Power Supply Battery Life Automatic Shut Off Environmental Weight without clamp Dimensions without clamp Operating Temperature Storage Temperature Warranty 1m 200 m 3 ft 650 ft Trimble warrants the HL450 to be free of defects in material and workmanship for a period of three years 3 year limited 2 years free exchange 3rd year a fee is charged Trimble or its authorized service center will repair or replace at its option any defective part or the entire product for which notice has been given during the warranty period If required travel and per diem expenses to and from the place where repairs are made will be charged to the customer at the prevailing rates Customers should send the product to Trimble Navigation Ltd or the nearest authorized service center for warranty repairs or exchange freight prepaid Any evidence of negligent abnormal use accident or any attempt to repair the product by other than factory authorized Low 65 dBA personnel using Trimble certified or recommended parts automatically 2 x 1 5 Volt AA batteries voids the warranty The foregoing states the entire liability of Trimble 70 hours regarding the purchase and use of its equipment Trimble will not be 30 min held responsi
3. ble for any consequential loss or damage of any kind This Waterproof Dustproof to IP67 warranty is in lieu of all other warranties except as set forth above 371 g 13 1 oz including any implied warranty merchantability of fitness for a particular 168 0 x 76 0 x 36 0 mm purpose are hereby disclaimed This warranty is in lieu of all other 6 6 x 3 0 x 1 4 warranties expressed or implied 20 C 60 C 4 F 140 F 40 C 70 C 40 F 158 F 102mm 45 76mm 35 10mm 0 05in 1 16 in 5 0mm 0 20in 1 4 in 0 1mm 0 01 in 1 64 in 45 minimum 610 nm 900 nm Loud 100 dBA Specifications subject to change without notice Notice to Our European Union Customers For product recycling instructions and more information please go to www trimble com environment summary html Recycling in Europe To recycle Trimble WEEE call 31 497 53 2430 and ask for the WEEE associate or Mail a request for recycling instructions to Trimble Europe BV c o Menlo Worldwide Logistics Meerheide 45 5521 DZ Eersel NL Trimble Trimble Construction Division 5475 Kellenburger Road Dayton Ohio 45424 1099 U S A 1 937 245 5600 Phone CE 2009 Trimble Navigation Limited All rights reserved Reorder PN 1277 3950 11 09 www trimble com HL450 Laserometer User Guide SPECTRA Trimble www trimble com 3 2 4 5 6 7
4. cks into the locked position AA ey HS eS in ag nn sai sony ITN Full Half Outline Flashing Batteries Initial Approx Change OK Warning 30 Minutes Batteries Remaining Rod Clamp 1 Captive Rod Clamp Screw attaches to the back of detector Alignment Points 2 help secure and align rod clamp Clamping Screw Knob secures clamp to rods by moving the traveling jaw Clockwise tightens Counterclockwise loosens Reference Bar top of bar is aligned with on grade Traveling Jaw moving jaw grips tightly to rods Action Display Turn power ON OFF emm in ft oe EH EN Press to turn power ON Press and hold for 2 seconds to turn power OFF Select accuracy Press once to display current setting push again to scroll through options Select beeper volume Press once to change current setting A beep confirms the selected volume Select units of measure Press once to display current setting additional pushes to scroll through options Remarks Initialization 1 Test of LCD and beeper 2 CAL Calibration 3 sec 3 Unit is ready for use Do not power up the unit in a laser beam or strobe If detected the unit will display E200 and revert to the previous calibration Accuracy in mm y The selected unit of measure determines 1 0 5 0 the displayed deadband accuracy Y y The current accuracy is stored in memory Z and will be retained when
5. the unit is turned A A off or when batteries are replaced 4 4 No symbol The current beeper volume is stored in Beeper Beeper Beeper memory and will be Loud Low Off retained when the unit is turned off or when bat teries are replaced mm in frac ft The current unit of measure is stored in memory and will be retained when the unit is turned off or when batteries are replaced
6. tions to the receiver that are not ex pressly approved by Trimble could void authority to use the equipment Declaration of Conformity Application of Council Directive s 89 336 EEC Manufacturer s Name Trimble Navigation Ltd Manufacturer s Address 5475 Kellenburger Road Dayton Ohio 45424 1099 U S A Trimble GmbH Am Prime Parc 11 65479 Raunheim Germany Model Number HL450 Conformance to Directive s EC Directive 89 336 EEC using EN55022 and EN50082 1 ITE residential commercial amp light industrial Product meets the limit B and methods of EN55022 Product meets the levels and methods of IEC 801 2 8 kV air 4 kV contact IEC 801 3 3 V m 26 to 1000 MHz 80 1 kHz European Representative Address Equipment Type Environment Product Standards N Rear view 8 Battery Door amp Latch for two AA batteries 9 Marking Notch 3 15 in 80 0 mm from top 10 Captive Screw Thread 11 Clamp Guides Dimples align rod clamp 12 Serial Number ID Label 13 Rear LCD repeats indications of front LCD Installing the Batteries al e L a ee gt 1 Open the battery door using a coin or similar pry device to release the battery door tab l Genet 2 Insert two AA batteries noting the plus and minus diagrams inside the battery housing b 3 Close the battery door Push down until it cli
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 業 務連 絡 平成27年3月 5 日 (公ネ土)秋田県トラック協会 会 員 様 今般 Behringer DI800 Quick Start Guide Weber 89563 Owner's Manual Operating instructions M4Q045CA0375 User manual ALFA 11 and ALFANET 11 0/+99OC(1) USER MANUAL 23352-01A Sac isotherme thermoélectrique Mode d`emploi SAN垣雪Tsu sanwmc Copyright © All rights reserved.