Home
Sony VPL-VW100 User's Manual
Contents
1. Request Data r Request Item No _ Length Data SET 00h Item No n Set Data n byte Response OK 01h Item No 0 3 4 1 5 GET Request The GET request is used to acquire the value of the specified item Details of the request and the response are described below Request Data r Request Item No I Length GET 01h Item No 0 Response OK 01h Item No n Get Data n byte 3 4 1 6 ERROR Response When an error occurs in the contents of a request or in the result of execution NG is returned as the response NG 00h Item No 2 Error Code 16 VPL VW100 3 4 2 Items Category Contents Used to control and to change the various setups Used to acquire the status Used to reset memory Sircs 15 bit category Sircs 20 bit category Used to acquire equipment information Used to acquire network setup information 3 4 2 1 Model Dependent Category The supported contents of 00 h 01 h 03 h 17 h and 19 h change depending on the model Details are shown on Appendix 3 4 2 2 Equipment Information Acquisition 80 h Used to acquire the equipment information Lower byte Contents Category Code Model name Serial number Installation location 0x8000 Category code 1 byte 0x8001 Mod
2. 14 VPL VW100 3 4 3 1 Item Error This error occurs when the Item No of a request is illegal or its data is illegal The conditions for occur rence of the respective errors are shown below Invalid Item An unsupported Item No is specified Example 1 The unsupported category is specified Example 2 The unsupported Item No 0x8010 is specified Invalid Item Request The Item No is supported but an unsupported Request is issued Example An attempt is made to set data in the Model Name 0x8001 Invalid Length Data length of the specified Item No is too long Example An attempt is made to set 25 byte data in the installation location 0x8003 Invalid Data Data of the specified Item No is outside the setting range Example An attempt is made to set 101 in the Item when the setting range of the Item is 1 to 100 Short Data The length of data is shorter than the value specified by the data length Example The actual data length is 9 bytes but data length is 10 Not Applicable Item An item that is not valid at present is specified Example The item to switch the display is specified when the main power is off 3 4 3 2 Community Error This error occurs when community is different Example ABCD is specified when SONY is set VPL VW100 15 3 4 3 3 Request Error This error occurs when header or command is illegal The conditions of occurrence of the respective errors are s
3. Adding the transmission place VPL VW100 3 2 PJ Talk The remote control service is provided that can control the projector from remote location via network 3 2 1 Function This responds to the control command and requests for acquiring the status and information supplied from clients Control request Enables the input to be selected and picture control to be adjusted SIRCS request Enables remote control by sending the SIRCS code Status request Enables equipment status information such as power status error information and power on time to be acquired Information request Enables equipment information such as equipment name serial number and installation information to be acquired Protocol Protocol name SDCP Simple Display Control Protocol Transport TCP Port number 53484 Factory shipments value TCP connection timeout 30 seconds Factory shipments value 3 2 2 Setup Items The items that can be set for the PJ Talk service are described below Setup item Description Port No Port number Timeout TCP connection timeout time Host Address IP address of connectable PC VPL VW100 3 3 SDAP Protocol This section describes the SDAP packet structure Header Community Product name Serial No Soe Location 4 4 12 4 2 24 Fig 1 Packet structure 1 Header The header consists of ID 16 bit version 8 bit
4. 2 4 Connection lt RS 232C Connection gt Communication is enabled by the use of a D Sub 9 Pin cross reverse cable The pin assignment of D Sub 9 Pin and D Sub 25 Pin is as follows D Sub 9 Pin D Sub 25 Pin Name Shell FG Grounding for safety protection or cable shield Transmission data Reception data Transmission request Transmission permission Data set ready GND for signal Data channel signal carrier detection Data terminal ready Calling display Presence absence of calling signal INIA 3 2 7 8 6 5 1 4 9 Pins indicated as D Sub 25 Pin are not used Assured cable length 15 m However assurance may not be applicable for some cables The software for controlling the projector from a PC is intended for performing transmission and recep tion for only the TxD and RxD lines Therefore there is no handshake normally performed by RS 232C 2 5 Communication Procedure 2 5 1 Outline of Communication All communication between CONTROLLER PC etc and DEVICE PROJECTOR is performed by the command block format Communication is started by the issue of a command at CONTROLLER and ended when the return data is sent to CONTROLLER after DEVICE receives the command CONTROLLER is prohibited from sending several commands at one time This means that after CON TROLLER sends one command it cannot send other commands until DEVICE returns the return data DEVICE sends the return dat
5. 01 Answer 1011 1001 1010 1011 OxBB VPL VW100 2 3 Block Format Transmission from the Master side BO START CODE B1 ITEM NUMBER B2 B3 SET GET B4 DATA B5 B6 CHECK SUM B7 END CODE Reception in the Master side BO START CODE B1 ACK NAK B2 B3 ACK DUMMY DATA B5 B6 CHECK SUM B7 END CODE Reception in the Master side With Data BO START CODE B1 ITEM NUMBER B2 B3 REPLY B4 DATA B5 B6 CHECK SUM B7 END CODE VPL VW100 Data transmission to the Projector Start of Command Set the Data Category Value desired Refer to the Appendix Table 1 for details SET 0x00 Set data GET 0x01 Get data SET Data to be set Refer to the Appendix Table 2 GET Unused Set Dummy data 0x00 0x00 Check Sum End of Command Receive results of the data transmission from the Projector Start of Command Results correspond with the data transmission Refer to the Appendix Table 3 for the data in detail 0x03 Express Reply data either of ACK or NAK This data does not mean any senses Dummy Data 0x00 0x00 is stored Check Sum End of Command Receive data from the Projector Start of Command Data to acquire Refer to the Appendix Table 1 in detail 0x02 Express data to be Reply data Received data Refer to the Appendix Table 2 in detail Check Sum End of Command
6. 08h Control Mode 05h User Mode 00h 00h Service Mode 00h Oth Lamp Timer 13h Lamp Use Time 0000h FFFFh 1 ROM Version 1Dh MAIN ROM Version 2 SC ROM Version 1Eh SC ROM Version 2 NVM Data VERSION 27h NVM data VERSION 3 W B All Save W B Low Save W B High Save W B Middle Save W B Custom1 Save W B Custom2 Save W B Custom3 Save 04h 05h 06h 07h 08h 09h OAh Set only Sircs 15 bit category Refer to Table4 Sircs 20 bit category Refer to Table5 Example In case the lamp timer indicates 1000H return values 03h upper byte and E8h lower byte 2 Example In case the software version is 1 03 return values are 01h upper byte and 03h lower byte 3 Example In case the NVM data version is 3 return values are 00 upper byte and 03 lower byte 4 Itis corresponded to single command only 20 VPL VW100 lt Table 3 gt Item Number Data Item Data Upper byte Lower byte Undefined Command Size Error Select Error Range Over Not Applicable Check Sum Error Framing Error Parity Error Over Rub Error Other Comm Error Waiting time for the return value is about 200 msec This waiting time for the return value is subject to the conditions that commu nication is not bothered by any reasons VP
7. IN RED Setting value 30 to 30 E2h to 1Eh 30 to 30 USER GAIN GREEN Setting value 30 to 30 E2h to 1Eh 30 to 30 USER GAIN BLUE Setting value 30 to 30 E2h to 1Eh 30 to 30 USER BIAS RED Setting value 30 to 30 E2h to 1Eh 30 to 30 l USER BIAS GREEN Setting value 30 to 30 E2h to 1Eh 30 to 30 USER BIAS BLUE Setting value 30 to 30 E2h to 1Eh 30 to 30 GAIN RED Setting val 00h 00h to FFh GAIN GREEN Setting val 00h 00h to FFh GAIN BLUE Setting val 00h 00h to FFh BIAS RED Setting val 00h 00h to FFh BIAS GREEN Setting val 00h 00h to FFh BIAS BLUE Setting val 00h 00h to FFh VPL VW100 19 lt Table 1 gt Status Error Upper byte Lower byte No Error lt Table 2 gt Upper byte 00h Lower byte 00h Get only Lamp Error 00h Oth Fan Error 00h 02h Cover Error 00h 04h Temp Error 00h 08h D5V Error 00h 10h Power Error 00h 20h Temp Warning Error 00h 40h NVM Data Error 00h 80h Status Power Stanby 00h 00h Start Up 00h Oth Start Up Lamp 00h 02h Power On 00h 03h Cooling1 00h 04h Cooling2 00h 05h Saving Cooling1 00h 06h Saving Cooling2 00h 07h Saving Stanby 00h
8. L VW100 21 M List of SIRCS CODE lt 15 CATEGORY Table 4 gt x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xA xB SD SE xF once CONTRAST CONTRAST COLOR BRITNESS BRITNESS vel HIGH LOW LOW BRIGHT DARK POWER HUE HUE SHARPNESS J SHARPNESS PICTURE STATUS STATUS POWER PURPLISH GREENISH SHARP SOFT MUTING ON OFF MENU ele COMPONENT On OFF CURSOR CURSOR CURSOR CURSOR gt lt T 4 MEMORY S VIDEO LENS LENS SHIFT T SHIFT l 1 When the Standby mode is set to Low the projector enters the Power Saving mode in about 1 minute after Standby If any command is sent during the Standby mode Not Applicable is returned However if the same command is sent again the command will be executed lt 20BIT CATEGORY Table 5 gt x0 x1 x2 x3 x4 x5 x6 x7 x8 x9 xB SC SD SE xF ADJUST PICTURE TOGGLE V KEYSTONE DRC MODE TOGGLE PICTURE PICTURE PICTURE PICTURE PICTURE PICTURE PICTURE MODE MODE MODE MODE MODE MODE MODE TGL DYNAMIC STANDARD CINEMA USER1 USER2 USER3 WIDE MODE DOT LENS LENS LENS TOGGLE PHASE ZOOM SHIFT FOCUS LENS CONT TOGGLE OOLMA 1dA TOV 7 TVD EE oc HOES LIC CHEB LED MHA GRE RFE B TeEPRLLET The material contained in this manual consists of information
9. SON Y VIDEO PROJECTOR VPL VW100 PROTOCOL MANUAL 1st Edition ASS Oe C EXAHA CTS BARN COVIaYIVIZARANERMIEPRT AR HR ERTS CHORO AFFBUZDEMATEMHBOVET z xus X EXhkhl zZI XEZVEKWADILIEMJARZ EEN A WARNING This manual is intended for qualified service personnel only To reduce the risk of electric shock fire or injury do not perform any servicing other than that contained in the operating instructions unless you are qualified to do so Refer all servicing to qualified service personnel A WARNUNG Die Anleitung ist nur f r qualifiziertes Fachpersonal bestimmt Alle Wartungsarbeiten d rfen nur von qualifiziertem Fachpersonal ausgef hrt werden Um die Gefahr eines elektrischen Schlages Feuergefahr und Verletzungen zu vermeiden sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen Andere als die angegeben Wartungsarbeiten d rfen nur von Personen ausgef hrt werden die eine spezielle Bef higung dazu besitzen A AVERTISSEMENT Ce manual est destin uniquement aux personnes comp tentes en charge de l entretien Afin de r duire les risques de d charge lectrique d incendie ou de blessure n effectuer que les r parations indiqu es dans le mode d emploi moins d tre qualifi pour en effectuer d autres Pour toute r paration faire appel une personne comp tente uniquement VPL VW100 Table of Contents 1 Introduction 2 RS 232C 2 1 Communication Spec
10. a after processing the command The time from when CONTROLLER sends the command until the return data is returned differs according to the contents of the command When Sircs Direct Command is sent return data may not be returned in some cases 4 VPL VW100 2 6 Communication Rules When sending a command from CONTROLLER the return data from PROJECTOR should be re ceived first before sending the next command Even if the next command is sent before receiving the return data since PROJECTOR will not be able to receive that command it does not return a response to CONTROLLER Consequently no error code is also sent The following lists the approximate waiting times for PROJECTOR to return the return data after CONTROLLER sends the command When a communication error occurs PROJECTOR ignores the data received until now and set into the reception standby state For undefined commands or commends determined as invalid by PROJECTOR PROJECTOR will send the return data to CONTROLLER Take note that when data is written when the input signal of PROJECTOR is unstable that data value will not be incorporated When INDEX specified SIRCS direct command is transmitted leave an interval of 45 msec until the next transmission Do not return the return data ACK NAK when the SIRCS direct command is received 2 7 Approximate Return Waiting Times The await return time is approx 30 msec This is the case unless the communic
11. and category 8 bits 0 1 2 3 Bit position 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 DA 16 Version 8 Category 8 Fig 2 Header ID It is fixed to DA Version This indicates the version number of protocol It is fixed to O1h version 1 Category Category number OAh of the projector is entered here 2 Community Refer to 3 4 1 2 The community that is set in the display equipment is entered Bit position 1 2 ER 0 0 1 2 3 4 5 6 78 9 0 1 2 3 4 5 6 7 8 9 0 1 2 T T T T T T T T T T T l A BE Communitv 32 Fig 3 Communitv 3 Equipment Information Product Name Name of equipment Maximum twelve characters In case less than twelve characters is entered in the blank space Serial No Serial number is entered Power Status Power supply status of the equipment is entered Location Information of installation location Maximum twenty four characters In case less than twenty four characters is entered in the blank space 8 VPL VW100 3 4 SDCP Protocol This section describes the packet structure of version 2 Header 2 Community Command 4 4 Data n 3 4 1 Fig 1 Packet structure Format 3 4 1 1 Header The header consists of version 8 bits and category 8 bits 0 1 Bit position 0 1 2 3 4 5 6 7 8 9 0 1 2 3 4 5 T T T T T T T T T jj T T T T Versi
12. ations are interfered anyway VPL VW100 3 NETWORK This section describes the performance operations and protocol to be used of advertisement and PJ Talk 3 1 Advertisement The advertisement service is provided to facilitate development of a PC application that can automatically detect a projector on the network This function is achieved by broadcasting the equipment information periodically to the network 3 1 1 Function The equipment information shown below is transmitted as the broadcast packet periodically at certain intervals Information Description Category Category of the equipment Equipment name Name of the equipment Serial number Serial number of the equipment Installation information Installation location of the equipment Community Community name of the equipment Power status Power status of the equipment The category of projector is Ox0a The power status sets ffffh if communication error occurs Protocol The SDAP protocol is defined in order to provide this service Protocol name SDAP Simple Display Advertisement Protocol Transport UDP Port number 53862 Factory shipments value Broadcast interval Once every 30 seconds Factory shipments value 3 1 2 Setup Items The items that can be set for the advertisement service are described below Setup items Description Port No Port number Interval Broadcast interval Broadcast Address
13. el name Alphanumeric 12 characters If the number of characters is less than 12 the remaining digits are filled with 00h 0x8002 Serial number 4 bytes The serial number is in the range of 00000000 to 99999999 0x8003 Installation location Alphanumeric 24 characters If the number of characters is less than 24 the remaining digits are filled with 00h 12 VPL VW100 3 4 2 3 Network Information Acquisition 90 h Used to acquire the network setup information Lower bytes Contents MAC Address IP Address Subnet Mask Default Gateway DHCP 0x9000 Mac Address 6 bytes 0x9001 IP Address 4 bytes 0x9002 Subnet Mask 4 bytes 0x9003 Default Mask 4 bytes 0x9004 DHCP 1 byte DHCP invalid 0 DHCP valid 1 VPL VW100 13 3 4 3 Error Code The error code list is shown below with a detailed description of each Category Error Code Item Error 01 h Invalid Item Invalid Item Request Invalid Length Invalid Data Short Data Not Applicable Item Community Error 02 h Different Community Request Error 10 h Invalid Version Invalid Category Invalid Request Short Header Short Community Short Command Network Error 20 h Timeout Comm Error FO h Timeout Check Sum Error Framing Error Parity Error Over Run Error Other Comm Error Unknown Response NVRAM Error F1 h Read Error Write Error
14. er byte Upper byte Lower byte 00h 01h Video 00h Set Get S Video 01h Input A 02h Component 03h HDMI 04h DVI 05h Picture Mode Dynamic 00h Standard 01h Cinema 02h Useri 03h User2 04h User3 05h 00h to 64h Brightness Setting value 0 to 100 00h to 64h Color Setting value 0 to 100 00h to 64h Contrast Setting value 0 to 100 Hue Setting value 0 to 100 00h to 64h Sharpness Setting value 0 to 100 00 to 64h Col Temp High 00h Mid 01h Low 02h Custom1 03h Custom2 04h Custom3 05h DRC MODE Off 00h Mode1 Oth Mode2 02h Black Level Adj Off 00h Low Oth High 02h Advanced Iris 00h Oth 02h RCP 00h Real Color Processing 01h 02h 03h Film Mode 00h 01h 18 VPL VW100 lt Table 1 gt lt Table 2 gt Item Upper byte Lower byte Upper byte Lower byte Wide Mode 00h 20h Full 00h 00h Set Get Normal 00h 01h Wide Zoom 00h 02h Zoom 00h 03h Subtitle 00h 04h Gamma Correction Off 00h 00h Gamma 1 00h Oth Gamma 2 00h 02h Gamma 3 00h 03h OverScan 00h 00h On 00h 01h Screen Area Full 00h 00h Through 00h Oth Off 00h 00h Low 00h Oth Middle 00h 02h High 00h 03h PictureMuting 00h 00h On 00h 01h Input A Signal Sel Auto 00h 00h Computer 00h 01h Component 00h 02h Video GBR 00h 03h DVI Signal Sel Auto 00h 00h Computer 00h 01h Video GBR 00h 03h Color Space Normal 00h 00h Wide 00h Oth USER GA
15. hown below Invalid Version The version of the header is other than 2 When another version is supported an error occurs in all versions other than the supported version Invalid Category The category does not match Example OxOB is specified in the device of category 0x0A Invalid Request An unsupported request is specified Example Request 0x02 is specified Short Header The received data is 1 byte Short Community The received data is in the range of 2 to 5 bytes Short Command The received data is in the range of 6 to 9 bytes 3 4 3 4 Network Error This is an error that occurs in TCP IP The conditions of occurrence of the respective errors are shown below Timeout Communication was interrupted 16 VPL VW100 3 4 3 5 Comm Error This is an error in communication with the main control microprocessor of the display Timeout Reception data is not returned after data is sent Check Sum Error A check sum error occurred in the main control microprocessor of the display Framing Error A framing error occurred Parity Error A parity error occurred Over Run Error An overrun error occurred Other Comm Error Another error occurred Unknown Response The data cannot be processed was received 3 4 3 6 NVRAM Error Read Error Reading from was failed Write Error Writing to NVRAM was failed VPL VW100 17 Appendix lt Table 1 gt lt Table 2 gt Item Upper byte Low
16. ifications sss 1 2 2 Command Block Format 2 2 3 Block Format 2 4 Connection en m 2 5 Communication Procedure sees 4 2 5 1 Outline of Communication eese 4 2 6 Communication Rules essere 5 2 7 Approximate Return Waiting Times sss 5 3 NETWORK 341 Adyvertisenient EEN 6 3 1 1 FUN U D eg Rec mee eere 6 3 1 2 Setup Items 16 3 2 ER 3 2 1 lotes 7 3 2 2 Setup Items te repre 7 3 3 SDAP Protocol ies eee eie rete 8 3 4 Protocol ee iere rire te 9 3 4 1 Otter eebe Ee e iere 9 324 131 ere 9 3 4 1 2 Community sese 9 3 4 1 3 Commande 10 3 4 1 4 SET Request sess 11 3 4 1 5 Request sse 11 3 4 1 6 ERROR Response eee 11 3 4 2 T MS 12 3 4 2 1 Model Dependent Category 12 3 4 2 2 Equipment Information Acquisition 80 h 12 3 4 2 3 Network Information Acquisition 90 h 13 3 4 3 Error Codes es cene e desc IU REI 14 3 4 3 L Item Error eee eere een vetns 15 3 4 3 2 Community Born 15 3 4 3 3 Request Error 3 4 3 4 Network Error 3 4 3 5 Comm Error 3 4 3 6 NVRAM Error VPL VW100 Appendix 1 Introduction This protocol manual describes the basic configuration and basic operations of various commands used for projector Projector can be control
17. led using the commands provided in Appendix Using an external CONTROLLER etc inputs can be switched and the power can also be turned on and off In the follow ing paragraphs CONTROLLER means an external device such as a PC which controls projector using these commands 2 RS 232C 2 1 Communication Specifications RS 232C Communication Signal Full duplex communication channels Flow control not performed Start stop synchronism system Baud rate 38 4 kbps bits per second The bit configuration is defined as follows 1 START Bit 8 DATA Bits 1 PARITY Bit 1 STOP Bit START DO D1 D2 D3 D4 D5 07 JPARITVJ STOP BIT LSB MSB EVEN BIT EVEN Parity Total number of 1 s from DO to D7 is an even number gt 0 sities Total number of 1 s from DO to D7 is an odd number 1 VPL VW100 2 2 Command Block Format The code from BO to B7 as described below are transmitted Transmission from Reception in Reception in the Master side the Master side the Master side With Data START CODE 0xA9 ITEM NUMBER ACK NAK ITEM NUMBER SET GET ACK REPLY DATA DUMMY DATA DATA B6 CHECK SUM B7 END CODE 0x9A BO START CORD Common in the all FORMAT B6 CHECK SUM B1 to B5 are calculated by OR Example of Calculation OxA9 1010 OxA9 1010 Answer 1010 B7 END CODE Common in the all FORMAT 1001 1001 1001 Us AO US AO 1010 Ox9A 10
18. of request One is the GET request to acquire the projector information and status The other is the SET request to modify the projector setup SET 00h Used to control turning the power on off and to control the input selector and to change the various setups GET 01h Used to acquire the installation information equipment status and various setup values Item No This is the item number of the request target Data Length This is the length of the data accompanying the request The maximum length is 128 bytes If there is no data it is O Data This is the data accompanying the request 2 Response This section describes the format of the response command which is used to return a response to the host PC from the projector Community The same alphanumeric characters as those of the request is entered Response The response returns the result of executing the request from the host PC Indicates that the request is illegal or cannot be executed Indicates that the request was executed correctly Item No The same value as those of the request is entered Data Length This is the length of the data accompanying the response The maximum length is 128 bytes If there is no data it is O Data This is the data accompanying the response 10 VPL VW100 3 4 1 4 SET Request The SET request is used to set a new value in the specified item Details of the request and the response are described below
19. on 8 Category 8 Fig 2 Header structure Version This indicates the version number of protocol It is fixed to 02h version 2 Category Category number QAh of the projector is entered here Projector checks the category number If a differ ent category number is entered the request is ignored 3 4 1 2 Community When the community data matches the community that is set in the display equipment the request is executed Community consists of four alphanumeric characters case sensitive All display equipment has the default value SONY when shipped from the factory Da 1 2 34567890 1 T T T 2 3 4 5 6 7 8 9 0 1 2 3 4 5 6 7 8 9 0 1 T T T T T T T T T T T T 2 3 Bit position Community 32 Community should be entered with four characters Three characters or less are not accepted VPL VW100 3 4 1 3 Command This section describes the format of the request command and the response command 0 1 2 3 Bit position 0 11779 8 0 1 2 0 0 867 7 079 001 T T T T T T T T T T T T T T T T T T T T T T T T Request Response 8 Item No 16 Data Length 8 1 Request This section describes the format of the request command that is issued from the host PC to the projector Community This is the same alphanumeric characters as those of community that is set in the projector to which request is going to be sent Request There are only two types
20. that is the property of Sony Corporation Sony Corporation expressly prohibits the duplication of any portion of this manual or the use thereof for any purpose other than the operation or maintenance of the equipment described in this manual without the express written permission of Sony Corporation Le mat riel contenu dans ce manuel consiste en informations qui sont la propri t de Sony Corporation Sony Corporation interdit formellement la copie de quelque partie que ce soit de ce manuel ou son emploi pour tout autre but que des op rations ou entretiens de l quipement moins d une permission crite de Sony Corporation Das in dieser Anleitung enthaltene Material besteht aus Informationen die Eigentum der Sony Corporation sind Die Sony Corporation untersagt ausdr cklich die Vervielfaltigung jeglicher Teile dieser Anleitung oder den Gebrauch derselben f r irgendeinen anderen Zweck als die Bedienung oder Wartung der in dieser Anleitung beschriebenen Ausr stung ohne ausdr ckliche schriftliche Erlaubnis der Sony Corporation VPL VW100 7 English VPL VW100 SY E Sony EMCS Corporation 2005LR16 1 9 872 775 01 Ichinomiya Tec 2005