1. 4000CL MAV PBIO User Manual doc 2 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option N CA Q 10 14 17 19 20 1 REVISION HISTORY 120602 040303 100903 112503 121003 020504 080604 Rev 3 0 Rev 3 1 Rev 3 2 Rev 3 3 Rev 3 4 Rev 3 5 Rev 3 6 Added GPI s Added Key Layout Company header information revised Updated Transmit Cue List Function and Receive Cue List Function description Changed Key Layout Added DNF Controls Limited Warranty Added LOOP A CLIP Section Revised TRIM CLIPS Section Added Video Sync Video Standard Recall Menu Options Added note to cover Supports up to 4 Video Server Channels Added T bar dimension 3 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option Getting Started 2 SYSTEM DESCRIPTION Q NOW production switchers can load amp play video clips on Sony MAV DDRs Q Use the EMEM or SNAPSHOT Learn amp Recall functions of the production switcher to load and play a video clip from a Recall or timeline Usethe Run and Trigger functions of the production switcher to Play Stop Recue the video clip Q Instantly load a video clip at the press of a button Instantly load a FILL clip amp KEY clip at the press of ONE button then play out both channels in sync LOOP up to 4 channels Q Control up to 4 video channels individually or
2. 5 Spare POWER CONNECTOR 9 Pin D Type Male Pin 1 5v DC 6 5 VDC 2 5v DC 7 Ground 3 Ground 8 Ground 4 12 VDC 9 Ground 5 12 VDC AUX CONNECTOR RS422 SERIAL CONNECTOR 9 Pin D Type Female DB9F Pin 1 Frame Ground 6 Common 2 No Connection T No Connection 3 Receive B 8 Receive A 4 Common 9 Frame Ground 5 Spare 17 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option GPI IN OUT CONNECTOR 15 Pin D Type Female DB15F Pin Description Function Pin Description Function 1 GPI 1 Out 9 GPI 1 In Play 2 GPI 2 Out 10 GPI 2 In Stop 3 GPI 3 Out 11 GPI 3 In Recue 4 GPI 4 Out 12 GPI 4 In Next Cue 5 GPI 5 Out 13 GPI 5 In Last Cue 6 GPI 6 Out 14 GPI 6 In Recall 7 GPI 7 Out 15 GPI 7 In 8 Ground 18 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option 20 KEY LAYOUT 57300 KEY CONFIGURATION 4000CL MAV T amp PBIO O i EVASI ST300 CONTROLLER 0 0d ok VIR QOOO 00 00 00 00 fl Fn s O o o ___ INICIA Nl WHITE QUITE LAST NEXT TIME IN OUT CUE CUE MODE MENU JOG SHUT nd UU U e LEER o o o RED KEYCAP IJ KEVCAPI HITE REVEAR REC LOOP CLIP SHIFT ENABLI LIST ESC KS Q KEYCAP sel aa a C s ST300 VTR DDR Control
3. The Trigger will be sent to the enabled VTR The other VTRs in the GANG will perform the same action 9 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option Advanced Features 11 12 CREATE NEW CLIPS NOTE Record duration must be set BEFORE creating a new clip a NOTE Press SHIFT RECORD The first line of the display shows current record duration The second line of the display prompts Enter record length Enter the desired record length using numeric keypad Press ENTER to save the entered time and exit OR Press ESC to exit without saving Default record duration is 30 minutes Select VTR Connection must be to the Recorder port on MAV 555 to create a clip Press CLIP LIST The CLIP LIST indicator will turn on The display prompts The display will show Enter New File Name Enter numeric CLIP ID up to 8 characters using the numeric keypad Press LOAD to create the selected CLIP ID OR Press ESC to exit at anytime NOTE The only functions available for new clips are RECORD and STOP In order to playback a newly recorded clip you must reload it on a Player port LOOP A CLIP Press LOOP ENABLE The indicator turns on The clip is now in the loop mode Pressing PLAY SLOMO FFWD etc will cause the clip to play to the end and wrap around to the beginning To return to normal mode press LOOP ENABLE The indicator will turn off 10 4000C
4. there is an option to set Parity to match the parity of the production switcher In hardware versions 2 0 and 2 1 this option is not offered as the hardware automatically adjusts for the parity When done press ESC to exit the MENU Configure the production switcher Enable the Peripheral Bus Enable the Peripheral Device Addresses assigned to the ST300 Enable the appropriate Learn Recall levels Enable the Timeline or Recall Trigger function 5 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option CONNECTION DIAGRAM SONY ST300 SSM MAV 555 PRODUCTION SWITCHER 3 4 1 2 GPI IN OUT POWER SUPPLY 6 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option VIDEO SERVER SETUP The SONY unit must have the following or higher software versions V1 1 Clips loaded from the front panel of the MAV will not be displayed on the ST300 SETUP MENU RECORD MODE Crash and Lockout are the only modes supported LOAD A CLIP Select VTR Connection must be to the Player port in order to load existing clips Press CLIP LIST The CLIP LIST indicator will turn on The display prompts WHEEL scroll files ENTER enter file ID Turn the Wheel to scroll through the list of available CLIPs OR ENTER a numeric file ID using the numeric keypad Press LOAD to load the desired clip Repeat steps a d until clips are loaded into the desired VTRs Set the GANG mode
5. ganged FEATURES The 4000CL MAV PBIO 400 Clip Instant Access System consists of the ST300 SSM with Cliplist software With this Option the ST300 has 4 Peripheral Device Addresses one for each VTR that it controls This allows the production switcher to control any and all VTRs connected to the ST300 Upon receipt of the Learn command from the production switcher the ST300 saves the CLIP IDs of the currently loaded clips the current time of each clip the VTRs they are loaded on and the current GANG mode into the appropriate Cue Point When the Recall command is received the ST300 loads the Learned Clips onto the Learned VTRs cues the Clip to the Learned time then restores the Learned GANG mode The Trigger function on the production switcher puts the selected VTRs into Play Stop Recue or other available modes DEFINITIONS Q Throughout this document Video Server refers to the MAV 555 Q The ST300 S SM as the ST300 Q Words surrounded by brackets for example ENTER are keys on the ST300 XXX XXX means hold the two keys down simultaneously Softkeys are the row of keys directly below the display that perform multiple functions in MENU and other modes 4 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option 1 SYSTEM INSTALLATION a ST300 S SM VTR DDR CONTROLLER 1 2 3 Plug one end of a 9 conductor RS422 serial cable into the 9 pin connector VT
6. the same as the switcher For hardware versions 2 0 and 2 1 no adjustment is provided or required RECORD Press Softkey to select single button or 2 button record RECORD REC Only OR REC PLAY PBIO ADDRESS Select to match the switcher output ALL hardware versions SWITCHER TYPE Select to match the switcher type ALL Hardware versions TRANSMIT CUELIST Transmit cuelist to another ST300 or to a PC RECEIVE CUELIST Receive cuelist from another ST300 or PC 15 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option 18 FUNCTION TABLE GOTO ENTERED SHIFT Search the VTR to the manually entered time TIME Use the ST300 numeric keypad Press ENTER or RECUE Press and HOLD to shuttle Release key to stop Set WIND Speed in MENU Select JOG mode and enable Wheel LAST CUE LAST CUE Step to the previous Cue Point Location NEXT CUE NEXT CUE Step to the next Cue Point Location RECORD Places VTR into the Record mode selected by RECORD MODE in the SETUP MENU Press RECORD or RECORD PLAY REC p Press and HOLD to shuttle Release key to stop Set WIND BRE in MENU SHUTTLE Select SHUTTLE mode and enable Wheel Press SLOMO to slo mo VTR Turn the Wheel or move the T Bar if available to change the play speed Press SLOMO to STILL frame OR Press any transport key to exit SLOMO SLO MO SPEED SHIFT SLOMO For WHEEL ONLY Pres
7. 12843 Foothill Blvd E Se Se m ee ENS ee Suite D m s a Sylmar CA 91342 mm w UN 818 898 3380 voice 818 898 3360 fax CONTROLS www dnfcontrols com Model No 4000CL MAV PBIO amp 4000CL MAV T PBIO 250 CLIP FAST ACCESS SYSTEM with Peripheral Bus Interface Option Sony DP Protocol for SONY MAV 555 Video Servers NOTE Supports up to 4 Video Server Channels USER MANUAL 1 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option Table of Contents 1 REVISION HISTORY GETTING STARTED 2 SYSTEM DESCRIPTION FEATURES DEFINITIONS 1 SYSTEM INSTALLATION a ST300 S SM VTR DDR CONTROLLER b PRODUCTION SWITCHER 2 VIDEO SERVER SETUP 3 LOAD A CLIP 4 LEARN ON THE ST300 7 LEARN ON THE PRODUCTION SWITCHER 8 RECALL ON THE ST300 9 RECALL ON THE PRODUCTION SWITCHER 10 PBIO ENABLE DISABLE 11 TRIGGERS FROM THE PRODUCTION SWITCHER ADVANCED FEATURES 11 CREATE NEW CLIPS 12 LOOPACLIP 13 SETTING THE IN OUT POINT a MARKING THE IN OUT POINT b VIEWING THE IN OUT POINT c CLEARING AN IN OUT POINT 14 TRIM CLIPS 15 VIEW CONTENTS OF CUE POINT 16 TRANSFERRING CUELIST a TRANSMIT CUE LIST FUNCTION b RECEIVE CUELIST FUNCTION REFERENCE 17 SETUP MENU 18 FUNCTION TABLE 19 SPECIFICATIONS ST300 17 20 KEY LAYOUT 21 DNF CONTROLS LIMITED WARRANTY Man al u u neu EYE RUE n Susu 3 6 080604 Document No
8. L MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option 13 SETTING THE IN OUT POINT a C MARKING THE IN OUT POINT 1 Press IN OUT The IN OUT indicator turns on The display shows IN OUT xx xx xx xx where xx xx xx xx is the saved time OR Press SHIFT IN OUT to manually enter a new IN OUT time 2 Press ENTER to save the entered time OR Press ESC to exit without saving NOTE When manually entering IN and OUT points they are always marked based on tape time not LTC no matter what time mode is selected VIEWING THE IN OUT POINT 1 When the IN OUT indicator is on Press IN OUT to view the existing IN OUT Point 2 While viewing the IN OUT Point Press MARK to overwrite the saved time with the current time Press RECUE to search to the IN OUT point CLEARING AN IN OUT POINT Press and hold DEL then press and release IN The IN OUT indicator turns off 14 TRIM CLIPS a b d LOAD the clip to be trimmed Mark IN and OUT points as described above Press SHIFT CLIP LIST The display prompts Enter new file name Enter new file name up to 8 characters using the numeric keypad Press ENTER or LOAD to save the new CLIP ID OR Press ESC to exit without saving If the saving is successful the new clip is created The beginning of the clip is the marked IN point and the end of the clip
9. M THE PC a Connect the VTR4 connector on the back of the ST300 to one of the COM ports on the PC using RS422 to RS232 adapter b Repeat steps b g of the TO RECEIVE CUE POINTS FROM THE ST300 section 13 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option Reference 17 SETUP MENU Press MENU The MENU indicator will turn on Turn the Wheel to select item to change Press MENU OR use the Softkeys to change the desired mode for that option Turn the Wheel at anytime to select another item Press ESC at anytime to exit SETUP MENU The MENU indicator will turn off MENU MODES Turning Wheel Clockwise RECORD Press MENU to select the desired record mode Lockout Crash Full WIND MODE Press Softkey to select HOLD Fast wind is maintained only while key is depressed OR LATCH Fast wind is initiated and maintained with momentary key press Select fast wind speed 3 9 to 23 7 by pressing Softkey below SPD SLOMO ST300 display shows Non T Bar version SLOMO with SpdRange ST300 display shows SLOMO with T Bar version Wheel SpdRange NOTE The T BAR has a fixed speed range of 0 gt 200 with a detent at 100 play speed Press Softkey TBAR or WHEEL to toggle between them For Wheel only Press Softkey SPDRANGE to select SLOMO speed ranges Press Softkey to select 0 gt 200 OR 100 gt 200 Press Softkey BACK to return to SLOMO MENU Pres
10. R 1 2 3 or 4 on the rear of the ST300 Plug the other end of the cable into the 9 pin REMOTE connector on the Video Server Connect the 5 12 12 VDC POWER SUPPLY into the POWER connector on the rear of the ST300 Plug the Power Supply into an outlet 90 VAC to 240 VAC Check SETUP MENU prior to using the ST300 to confirm proper Record mode and other User settable modes b PRODUCTION SWITCHER 1 2 3 4 5 6 Connect a standard cable RS422 9 pin serial cable to the AUX connector on the rear of the ST300 Connect the other end of the cable to the Peripheral Bus Connector on the production switcher Communication Format 38 4K N 8 1 The ST300 has 4 Peripheral Device Addresses one for each VTR that it controls To set the Device Address for each VTR a Press MENU and turn the Wheel until Peripheral Address is displayed b Press VTR 1 VTR 2 VTR 3 or VTR 4 to select a VTR c Assign a Peripheral Device Address for that VTR from 0 to 23 by entering the desired address using the numeric keypad NOTE Address 24 or greater will turn PBIO off d Select the next VTR and then assign a Peripheral Device Address for it Each VTR must have its own unique address To select a Production Switcher type Default Grass Valley Group a Press MENU and turn the Wheel until SWITCHER is displayed b Press the Softkeys to toggle between Sony and Grass Valley For version 3 0 hardware
11. if required Refer to the Function Table for Details Press ESC at anytime to exit CLIP LIST LEARN ON THE ST300 LOAD a clip as described above on the ST300 Set IN and OUT points if desired Select the desired Cue Point by pressing NEXT CUE LAST CUE OR By manually entering the Cue Point using the numeric keypad The selected Cue Point number is shown on the bottom line of the display Press SHIFT MARK to initiate the LEARN The ST300 will save loaded CLIP ID and current IN time to the selected Cue Point The display shows Select VTR Mark Learn ESC Cancel Press VTR 1 VTR 2 VTR 3 or VTR 4 to select the VTRs Press MARK The ST300 will LEARN save the current configuration which consists of Cue Point CLIP IDs In Times and Ganged VTRs 7 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option 7 LEARN ON THE PRODUCTION SWITCHER Select and enable the Peripheral Device Addresses for the ST300 b Do a LEARN to the desired REGISTER The ST300 will LEARN save the VTR loaded CLIP ID and current IN time to the REGISTER number in the ST300 8 RECALL ON THE ST300 a Select the desired Cue Point by pressing NEXT CUE LAST CUE OR By manually entering the Cue Point using the numeric keypad The selected Cue Point number is shown on the bottom line of the display b Press LOAD on the ST300 The ST300 will automatically load the LEARNED clip on the
12. is the OUT point The new clip can be loaded using the CLIP LIST function Upon saving the new clip marked IN and OUT points are cleared NOTE Do not create trimmed clips with a duration of less than 18 frames 11 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option 15 16 VIEW CONTENTS OF CUE POINT a Use NEXT CUE or LAST CUE to access Cue Point Contents loaded at this Cue Point CLIP ID will be displayed OR b Use numeric keypad to enter Cue Point number Press ENTER Contents are displayed TRANSFERRING CUELIST a TRANSMIT CUE LIST FUNCTION The TRANSMIT CUELIST function allows you to transmit your list of Cue Points to a PC using the provided utility software on the PC or to another ST300 Transfer to a PC requires OpSuite 3 0 software which runs on a Windows based computer Contact DNF Controls for more information 1 TO TRANSMIT CUE POINTS TO THE ST300 a Connect the VTR4 connector on the rear of the ST300 to the VTR4 connector of the receiving ST300 using an RS422 9 pin cable with TX and RX lines crossed A turnaround cable b Press MENU and scroll the wheel to Transmit CUE List YES Enter Exit ESC Press ENTER to start transmitting The Display shows Waiting to transmit d When the Receiver is ready transfer starts automatically The Display now shows Transmitting cuelist e After the transfer is over the display shows Transfe
13. ler 19 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option 21 DNF CONTROLS LIMITED WARRANTY DNF Controls warrants its product to be free from defects in material and workmanship for a period of one 1 year from the date of sale to the original purchaser from DNF Controls In order to enforce the rights under this warranty the customer must first contact DNF s Customer Support Department to afford the opportunity of identifying and fixing the problem without sending the unit in for repair If DNF s Customer Support Department cannot fix the problem the customer will be issued a Returned Merchandise Authorization number RMA The customer will then ship the defective product prepaid to DNF Controls with the RMA number clearly indicated on the customer s shipping document The merchandise is to be shipped to DNF Controls 12843 Foothill Blvd Suite D Sylmar CA 91342 USA Failure to obtain a proper RMA number prior to returning the product may result in the return not being accepted or in a charge for the required repair DNF Controls at its option will repair or replace the defective unit DNF Controls will return the unit prepaid to the customer The method of shipment is at the discretion of DNF Controls principally UPS Ground for shipments within the United States of America Shipments to international customers will be sent via air Should a customer require the product to be returned in a more ex
14. peditious manner the return shipment will be billed to their freight account This warranty will be considered null and void if accident misuse abuse improper line voltage fire water lightning or other acts of God damaged the product All repair parts are to be supplied by DNF Controls either directly or through its authorized dealer network Similarly any repair work not performed by either DNF Controls or its authorized dealer may void the warranty After the warranty period has expired DNF Controls offers repair services at prices listed in the DNF Controls Price List DNF Controls reserves the right to refuse repair of any unit outside the warranty period that is deemed non repairable DNF Controls shall not be liable for direct indirect incidental consequential or other types of damage resulting from the use of the product 20 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option
15. r is over for one second then shows Waiting to transmit again f Connect another ST300 to transmit the list again OR Press ESC twice to exit 2 TO TRANSMIT CUE POINTS TO THE PC a Connect the VTR4 connector on the back of the ST300 to one of the COM ports on the PC using a RS422 to RS232 adapter b Repeat steps b f of the TO TRANSMIT CUE POINTS TO THE ST300 section 12 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option b RECEIVE CUELIST FUNCTION The RECEIVE CUELIST function allows you to receive your list of Cue Points from a PC or from another ST300 Transfer to a PC requires OpSuite 3 0 software which runs on a Windows based computer Contact DNF Controls for more information 1 TO RECEIVE CUE POINTS FROM THE ST300 a Connect the VTR4 connector on the back of the ST300 from the VTR4 connector of the transmitting ST300 using RS422 9 pin cable with TX and RX lines crossed A Turnaround Cable b Press MENU and scroll the wheel to Receive CUE List YES Enter Exit ESC Press ENTER to start receiving The Display shows Waiting to receive d When the Transmitter is ready transfer starts automatically The Display now shows Receiving cuelist e After the transfer is over the display shows Done Success Press any key f Press any key The display shows Receive cuelist message g Press ESC to exit the MENU mode 2 TO RECEIVE CUE POINTS FRO
16. s ESC to exit OR turn the Wheel to select another item For Wheel only Press Softkey PRSET to select the SLOMO Preset Speed Mode Press Softkey UPDATE When exiting SLOMO mode the last used speed is saved in the Preset Speed register Press Softkey STATIC The Preset Speed register is NOT updated when exiting SLOMO mode It is only changed by SHIFT SLOMO PRESET SLOMO 14 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option ST300 SETUP ST300 SETUP SetDefault Clear Cues Press Softkey beneath ClearCues to clear all Cue Points to 00 00 00 00 Press Softkey YES when asked Are You Sure Press Softkey beneath SetDefault to set ST300 to default settings Press Softkey YES when asked Are You Sure DISPLAY The version number for the currently installed software is displayed SOFTWARE VERSION SYNC Set to ON if black burst is supplied to the Ref Video connector on the rear panel Set to OFF if no black burst is supplied VIDEO STANDARD Sets Video Standard option to NTSC when NTSC is pressed OR Sets Video Standard option to PAL when PAL is pressed RECALL MODE Press NORMAL or REDIR redirect NORMAL The cue point will load on the learned VTR REDIR When one and only one clip is learned into a Cue Point the Clip will be REDIRECTD to load on the currently selected VTR PARITY In hardware version 3 0 only set the parity to
17. s SHIFT SLOMO to preset the PRESET slo mo speed Turn the Wheel to select desired speed Press ESC or any transport key to exit Press once to STILL frame VTR Press again to put VTR into STOP mode GANG VTRs SHIFT VTR 1 Press and Hold SHIFT Then when lights go out press VTR OR keys to include in the gang Press SHIFT to escape gang SHIFT VTR 2 setup mode Flashing LED indicates VTR or HDD being OR monitored for status SHIFT VTR 3 OR SHIFT VTR 4 TIME MODE TIME MODE Press to toggle between Timecode TC VITC VT or Tape SELECT Timer TM display modes LOOP CLIP LOOP ENABLE Press to loop a clip 16 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option 19 SPECIFICATIONS ST300 Power Size Weight Rear Panel Connectors Display Jog Shuttle Wheel Optional T bar 90 VAC to 265 VAC adapter supplied with IEC connector L x W x H 12 x 6 x 1 5 front 3 0 rear T bar unit is 12 6 long 4 lbs VTRI VTR2 VTR3 All DB9F GRR S hee oh ace cem DBFISF DB9M AUX sect eee iei era ees DB9F Easy to read 2 line back lit LCD display User adjustable contrast With mechanical detents Slo mo 0 200 of Play Speed RS422 SERIAL CONNECTOR 9 Pin D Type Female Pin 1 Frame Ground 6 Receive Common 2 Receive A 7 Receive B 3 Transmit B gt 8 Transmit A gt 4 Transmit Common 9 Frame Ground
18. selected VTR and cue the clip to the LEARNED time 9 RECALL ON THE PRODUCTION SWITCHER a RECALL the desired REGISTER NUMBER b The ST300 will automatically load the Learned clips on the Learned VTRs cue the clips to the Learned time then set the Learned GANG mode 8 4000CL MAV 250 Clip Fast Access System for Sony MAV 555 with PBIO option 10 PBIO ENABLE DISABLE On the ST300 press the PBIO key to enable or disable PBIO When disabled the ST300 will ignore all Pbus commands When enabled the ST300 will respond to all Pbus commands When enabled and Pbus commands are received the key s LED will flash 11 TRIGGERS FROM THE PRODUCTION SWITCHER Firing a trigger using either the Timeline or Run function on the production switcher causes the ST300 to put the Video Server into the following modes based upon the trigger value GRASS VALLEY GROUP Trigger Value Mode 0 Play 1 Recue to beginning of clip 2 Slo mo using ST300 Preset Speed 3 Reverse Play 4 Still Frame 5 None 6 or greater Play SONY Trigger Value Mode 0 Recue to beginning of clip 1 Play 2 Slo mo using ST300 Preset Speed 3 Reverse Play 4 Still Frame 5 None 6 or greater Play To control more than one VTR enable the Peripheral Device Address for the required VTRs The Trigger will be sent to the enabled devices OR GANG the required VTRs on the ST300 See the Menu Table for GANG instructions Enable the Peripheral Device Address for one of the GANGed VTRs