Home
Soleus Air 90CFM User's Manual
Contents
1. Soleus Air Ultra Quiet Ventilation Fan Model No FE1 05 FE1 07 FE1 09 FE1 11 50 CFM 70 CFM 90 CFM 110 CFM Operating Instructions FE1 05 01 FE1 09 01 FE1 07 01 FE1 11 01 U SERTE LISTED sr US HHHHHH 3092716 FE1 Series Ventilation Fans 2007 Soleus Air International Thank you for choosing a Ventilation Fan This owner s manual will provide you with valuable information necessary for the proper care and maintenance of your new product Please take a few moments to thoroughly read the instructions and familiarize yourself with all the opera tional aspects of your new fan For your own records please attach a copy of your sales receipt to this manual Also write the store name location date purchased and serial number below Store Name Location Date Purchased Serial Number located on back of unit EE IMPORTANT SAFETY INSTRUCTIONS 1 This product must be installed by a qualified technician Do not mount in a ceiling thermally insulated to a value greater than R40 Designed to be mounted in the ceiling only a oe oS WARNING To reduce the risk of fire or electric shock do not use this fan with any solid state speed control device a WARNING To reduce the risk of electric shock disconnect power before servicing 6 NOTE For Use in Kitchens please refer to Figure 1 7 WARNING To reduce the risk of fire electric shock or injury to persons observe the following A Use this unit in th
2. Interrupter protected branch circuit F NEVER place a switch where 1t can be reach from a tub or shower HOUSING INSTALLATION REFER TO FIGURE 2 For FE1 09 amp FE1 11 Rough Opening 9 25 D x 9 25 W Housing Size 9 D x 7 75 H x 9 W For FE1 05 amp FE1 08 Rough Opening 6 75 D x 6 75 W Housing Size 6 625 D x 7 125 H x 6 625 W Continued on page 4 3 1 Remove the louver fan grate from the unit before mounting 2 Separate the air exhaust adaptor from the housing 3 Mount the air exhaust adapter to the wooden frame and secure using screws as show in Figure 2 4 Insert the housing to fit into the air exhaust adaptor and wooden frame Secure the housing to the wooden frame using screws To avoid vibration place rubber washers NEO NG AE between the housing and the wooden frame Secure the housing to the air exhaust adaptor using the provided OUNEN MOUNTING CLIP screws 5 The flange of the housing must be leveled for the louver to fit properly 6 Hang the unit to the roof using hangers when necessary OF FIGURE2 7 Both installations seen in figure 2 can be used at the same time WIRING REFER TO FIGURE 3 IMPORTANT The power must be disconnected before installation is complete IMPORTANT Be certain all wiring complies with local safety codes and standards and that the unit is properly grounded 1 Run the power leads from the wall switch time switch
3. e or other appearance parts caused by wear e Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus International Inc e Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT This warranty covers only new products purchased from our authorized dealers or retailers It does not cover used sal vaged or refurbished products As some states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For Technical Support amp Warranty Service Please Call 888 876 5387 Or Write To Soleus International Inc 9451 Telstar Ave El Monte CA 91731 USA www soleusair com
4. e manner intended by the manufacturer If you have questions please contact Soleus Air B Before servicing or cleaning the unit switch power off at the service panel and lock the service panel to prevent power from being switched on accidentally If the service panel cannot be locked securely fasten a prominent warning such as a tag onto the service panel DO NOT INSTALL ABOVE OR 8 CAUTION For general ventilating use only Do not use to aS in Te exhaust hazardous or explosive materials and vapors 7 gt RE COOKING EQUIPMENT FIGURE1 E INSTALLATION INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Installation work and electrical wiring must be done by qualified persons in accordance with all applicable safety codes and standards including fire rated construction B Sufficient air is needed for proper combustion and exhausting of gases through the flue of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the local code authorities C When cutting or drilling into a wall or ceiling do not damage electrical wiring and other hidden utilities D Ducted fans must always be vented to the outdoors E If the unit is to be installed over a tub or shower it must be marked appropriately for the application and connected to a GFCI Ground Fault Circuit
5. erse the plastic parts hot water over 100 F Routine maintenance is recommended every year 1 Remove the louver fan grate 2 Wash and clean the louver fan grate 3 Remove any dirt from the unit with a damp soft cloth and mild detergent Wipe to dry 4 After cleaning confirm that the fan has been properly reassembled a ES WARRANTY One Year Limited Warranty Soleus International Inc warrants the accompanying Soleus Air Ventilation Fan to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE 1 year from the date of original retail purchase in the United States If the unit exhibits a defect in normal use Soleus International Inc will at its option either repair or replace 1t free of charge within a reasonable time after the unit 1s returned during the warranty period AS a condition to any warranty service obligation the consumer must present this Warranty Certificate along with a copy of the original purchase invoice THIS WARRANTY DOES NOT COVER e Damage accidental or otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship e Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions This includes dents accidental or otherwise to the base and head of the unit e Damage to the finish of the cas
6. or speed control switch to the unit 2 Using approved wire connectors connect the supply wires to the fan wires black or brown to black or brown and white or blue to white or blue Connect the ground wire green or bare copper to the ground connection on the fan junction box SWITCH BOX TORRES BLACK BROWN r BLACK BROWN Lu WHITE BLUE s 4 x 1 WHITE BLUE AC POWER a 1 GROUNDING FAN HOUSING DUCTING REFER TO FIGURE 4 1 Run 4 round duct from the discharge opening to the outside of the house 2 Sheet metal duct is recommended Dryer hood type vent with FIGURE4 backdraft flap s RESIES NS OS Ee gt Caulk termination to duct EI ESRA SAIS X 2 3 ft straight run before elbow In attic installation caulk box to drywall Short piece of flexible duct 4 Zs helps alignment and absorbs i Insulation sound Clamps plus tape at all flex joints Foil tape tightly covers all metal duct joints glue PVC joints Es INSTALLING THE LOUVER REFER TO FIGURE 2 1 The louver fan grate can be installed when the ventilation fan installation is complete Place the louver s fan grate mounting clips in to the slot holes on both sides of the unit ES MAINTENANCE VVARNING DISCONNECT THE POVVER SOURCE BEFORE SERVICING NOTE Never use gasoline benzene thinner or any other chemicals for cleaning the ventilation fan Do not allovv vvater to get into the motor Do not imm