Home

Soleus Air SG-PAC-08E3 User's Manual

image

Contents

1. e Freight and Insurance cost for the warranty service ALL WARRANTIES INCLUDING ANY IMPLIED WARRANTY OF MERCHANT ABILITY ARE LIMITED TO ONE YEAR DURATION OF THIS EXPRESS LIMITED WARRANTY SOLEUS INTERNATIONAL INC DISCLAIMS ANY LIABILITY FOR CONSEQUENTIAL OR INCIDENTAL DAMAGES AND IN NO EVENT SHALL SOLEUS INTERNATIONAL INC S LIABILITY EXCEED THE RETAIL VALUE OF THE UNIT FOR BREACH OF ANY WRITTEN OR IMPLIED WARRANTY WITH RESPECT TO THIS UNIT This warranty covers only new products purchased from our authorized dealers or retailers It does not cover used sal vaged or refurbished products As some states do not allow the limitation or exclusion of incidental or consequential damages or do not allow limitation on implied warranties the above limitations and exclusions may not apply to you This warranty gives you specific legal rights and you may also have other rights that vary from state to state For Technical Support amp Warranty Service Please Call 888 876 5387 Or Write To Soleus International Inc 20035 E Walnut Dr North City of Industry CA 91789 USA www soleusair com www greeusa com 15
2. is still dis played contact customer service The LED Display is showing H8 The backup water tank is full Drain the water tank If the H8 is still displayed after the water tank has been emptied con tact customer service 14 ee WARRANTY One Year Limited Warranty Soleus International Inc warrants the accompanying Soleus Air Powered by Gree Portable Air Conditioner to be free of defects in material and workmanship for the applications specified in its operation instruction for a period of ONE 1 year from the date of original retail purchase in the United States If the unit exhibits a defect in normal use Soleus International Inc will at its option either repair or replace it free of charge within a reasonable time after the unit is returned during the warranty period As acondition to any warranty service obligation the consumer must present this Warranty Certificate along with a copy of the original purchase invoice THIS WARRANTY DOES NOT COVER e Damage accidental or otherwise to the unit while in the possession of a consumer not caused by a defect in material or workmanship e Damage caused by consumer misuse tampering or failure to follow the care and special handling provisions in the instructions e Damage to the finish of the case or other appearance parts caused by wear e Damage caused by repairs or alterations of the unit by anyone other than those authorized by Soleus Interna tional Inc
3. Failure when power is restored e There is a protective time delay approx 3 minutes to prevent tripping of the compressor overload For this reason the unit may not start normal cooling for 3 minutes after it is turned back on e Press the RESET button located The current interrupter device is on the power cord plug tripped e Ifthe RESET button will not stay engaged discontinue use of the air conditioner and contact a qualified service technician Airflow is restricted e Make sure there are no curtains blinds or furniture blocking the front of the air conditioner The Air Conditioner does not cool as it should The temperature control may not be e Lower the set thermostat tempera set correctly ture The air filter is dirty e Clean the filter See the Cleaning and Care Section of the manual The room may be too warm e Please allow time for the room to cool down after turning on the air conditioner Cold air is escaping e Check for open furnace registers and cold air returns The Evaporator is frozen e The unit is defrosting and will re sume operation when done The batteries are inserted incorrectly e Check the position of the batteries The Remote Control is not working The batteries may be dead e Replace the batteries 13 Z TROUBLESHOOTING CONT PROBLEM POSSIBLE CAUSES SOLUTIONS The LED Display is showing E5 Over Current Protection Unplug for 10 minutes and then turn on the unit If E5
4. air conditioner may not be able to evaporate all of the water as quickly as needed All moisture that is unable to be evaporated is placed in a small bank up water tank in side the unit When this tank is completely full an alarm will sound the compressor will shut off and the bucket full icon will light up on the control panel To manually empty the tank please follow the instructions below Drain Hose Drain Hose Clip Drain Plug 1 Remove the pre installed Drain Cap from the unit See Below 2 Attach the Clamp with the provided Screw See Below A Drain Port A Drain Port B Drain Cap B Clamp 3 Attach the Drain Hose to the Drain Port using the Drain Hose Clip Insert the Drain Plug into the free end of the Drain Hose and guide the Drain Hose through the Clamp Once finished the unit can be easily drained by removing the drain plug and guiding the drain hose into a small pan to drain the water A Drain Plug B Drain Port C Drain Hose D Drain Hose Clip E Clamp 11 27272707 MAINTENANCE Note Make sure power is off and the power cord is not plugged into an electrical outlet prior to performing any maintenance on the unit Clean or replace filter If the air filter 1s blocked with a dust the airflow volume may reduce It is recommended to clean the filter once every two weeks or as needed 1 Remove the filter from the filter compartment on the back of the unit 2 Wash the air f
5. minuts to 24 hours To set the Timer off press the TIMER button on the remote control Each touch of the buttons on the remote will change the timer setting in 30 minute 5 hour intervals EE REMOTE CONTROL OPERATING INSTRUCTIONS Cont Sleep Mode Press the SLEEP mode button to engage SLEEP mode Sleep mode automatically raises the set temperature by 2 F after one hour and 4 F after two hours This feature limits compressor usage and enhances energy savings while you are sleeping Auto Mode When AUTO mode is selected the air conditioner will automatically choose the operating mode base on the current room temperature When the room is below 68 F the air conditioner will automatically fan the room to circulate air When the room temperature is between 68 F 73 F the air conditioner will operate in Fan mode if it was previously selected or dehumidifier mode if another mode was used previously to remove humidity from the air as well as some cooling to help lower the room temperature When the room temperature is between 74 F 79 F the air conditioner will always operate in dehumidifier mode When the room temperature rises above 79 F the unit will operate in air conditioner mode to maximize cooling Auto mode uses pre determined settings to keep you comfortable by choosing the most energy efficient mode based on the temperature of the room 10 DRAINING COLLECTED WATER When the temperature or humidity is too high the
6. or lower than the minimum operating temperature the air conditioner may not work properly Model Number o ated Curenneatno amperes OOOO Noell Dimensions W x H x D H 8 8 8 8 pe E LCDI POWER CORD AND PLUG This air conditioner is equipped with an LCDI Leakage Current Detection and Interruption power cord and plug as required by US National Electric Code 440 65 This cord consists of a length of shielded flexible cord with no termination on the load side and a LCDI attachment plug on the line side The LCDI power cord and plug will remove the supply source via electrical disconnect circuit trip 1f the nominal current leakage between the cord shield and either load conductor exceeds a predetermined value The cord will remain de energized until the devise has been manually reset This is intended to reduce the risk of a fire in the power cord or combustible materials nearby The cord shields are not grounded and they must be considered a shock hazards if exposed The cord shield must not be connected to ground or to any exposed metal The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly To test 1 Plug power cord into wall outlet 2 Press TEST Button circuit should trip cutting power to the air conditioner 3 Press RESET button for use If a test is performed and the indicator light remains ON current leakage has been detected Do not use the air conditioner or attemp
7. the different modes Cool Dry and Fan only mode Each press of the MODE button will light up a different icon on the control panel The exhaust hose and window kit must be installed when the unit is in Cool or Dry mode When using the unit as a fan it is not necessary to keep the exhaust hose and window kit connected to the unit Temperature Select the desired temperature by pressing either or key when using the unit in cooling mode Louver Direction This unit has 4 Way directional louvers Use the louver guides to direct air where cooling or fanning is needed most Bucket Full When the unit cannot evaporate the collected moisture fast enough The excess water will collect in a backup water tank located inside the unit The bucket full icon will light up 1f this occurs L T REMOTE CONTROL OPERATING INSTRUCTIONS N T ON T OFF AUTO COOL DRY NOTE Heat mode is not available ie on the SG PAC 08E3 POWER BUTTON 0N0F MODE BUTTON TEMP SELECT BUTTONS FAN SWING TIMER a SWING te 7 LCD DISPLAY and LOCK SPEED MODE LABELS SWING BUTTON Not Available on SG PAC 08E3 FAN BUTTON SLEEP BUTTON TIMER BUTTON SOLEUSAI Powered by G GREE ed 1 Power On and Off Press the ON OFF POWER button once to manually turn the unit on Press the Power button once more to turn the unit off When you manually power the unit on and off by pressing the ON OFF button th
8. V 121010 SOLEUSA I powered oy Qu GREE Model SG PAC 08E3 KY 80 3 000 BTU Portable Air Conditioner Operating Instructions Thank you for choosing a Soleus Air Powered by Gree Portable Air Conditioner This owner s man ual will provide you with valuable information necessary for the proper care and maintenance of your new product Please take a few moments to thoroughly read the instructions and familiarize yourself with all the operational aspects of your new Portable Air Conditioner For your own records please attach a copy of your sales receipt to this manual Also write the store name location date purchased and serial number below Store Name Location Date Purchased Serial Number located on back of unit L IMPORTANT INSTRUCTIONS Before installing and using your portable air conditioner please read this owner s manual carefully Store this manual in a safe place for future reference 1 Always place the unit on a level surface 2 Never use or store gasoline or other flammable vapor or liquid near this unit unless instructed by this manual 3 Maintain at least 10 inches 25 cm clearance space around this unit Do not block or cover air inlet or outlet grilles 4 The unit must be connected to a correctly grounded power supply 5 Do not start or stop the unit by inserting or pulling out the power plug 6 Do not use an adapter plug or extension cord 7 Do not use the unit in the immediat
9. e end down to properly fit the opening figures e amp f 5 Attach the window kit adapter to the window kit figure g 6 Place the window kit back into the window and attach the exhaust hose to the window kit adapter figures h amp i Close the window tightly figure j Your Portable Air Conditioner is now ready to cool NOTE When using the venting system keep the exhaust hose as straight as possible The exhaust hose can be shortened but it is not recommended to increase the length of the exhaust hose Do not use an extension cord with your portable air conditioner This installation is OK The is a poor installation When installing the exhaust hose try and keep it as flat as possible The less angles and bends in the hose the better the unit will perform If bending or an angle is necessary use single 90 angles like the pictures above and below Multiple bends will decrease performance and effi ciency CONTROL PANEL DISPLAY amp OPERATING INSTRUCTIONS CONTROL PANEL amp LED DISPLAY BUCKET FULL LIGHT COOL MODE LIGHT DRY MODE LIGHT REMOTE RECEIVER LED DISPLAY FAN MODE LIGHT MODE MODE BUTTON TEMP SELECT BUTTON L POWER BUTTON CONTROL PANEL OPERATING INSTRUCTIONS 1 2 3 4 N Power On and Off Press the POWER button once to manually turn the unit on Press the POWER button once more to turn the unit off Mode Selection Press the MODE Button repeatedly to cycle between
10. e preset timer will be cancelled 2 Mode Selection Press the MODE Button repeatedly to cycle between the different modes Auto Cool Dry and Fan only mode Once a mode is selected an arrow will light up on the LCD display next to the selected MODE label on the remote Auto mode automatically chooses the Cool Dry or fan mode based on the current room temperature 3 Fan Speed Press the FAN speed button to cycle through low medium and high fan speeds The small fan icons will light up depending on which speed is selected The more fan icons light up the higher the speed The fan icons are located on the LCD display next to the SPEED label 4 Temperature Setting When the unit is in Air Conditioner mode you can select your desired temperature Press the TEMP SELECT buttons or to select your desired temperature setting The temperature on the LCD display on the remote control will increase or decrease accordingly Hold the buttons for two seconds to rapidly increase or decrease the temperature 5 Timer on When the air conditioner is off it can be set to automatically turn on in 30 minutes to 24 hours at the previous set mode and fan setting To set the Timer on press the TIMER button on the remote control Each touch of the buttons on the remote will change the timer setting in 30 minute increments 5 hours Timer off __ When the air conditioner is on it can be set to automatically turn off in 30
11. e surroundings of a bath a shower or a swimming pool 8 Do not insert anything into the air outlet Do not obstruct air inlet or outlet grills unless instructed by this manual 9 Do not let children play near this unit 10 Always inspect the cord for signs of damage before use If the power cord is damaged it must be replaced by the manufacturer or a qualified service technician 11 When cleaning the unit always turn the unit off and unplug the power cord 12 Do Not Mix Old And New Batteries Do Not Mix Alkaline Standard Carbon Zinc Or Rechargeable Nickel Cadmium Batteries PACKAGE CONTENTS Portable Air Conditioner Exhaust Hose 1 Exhaust Hose Adapter 1 Window Kit Adapter 1 Hose Adapter 1 Remote Control amp AAA Batteries 2 batteries Window Kit 3 Sliding Panels 4 screws 1 single hose panel 2 extension panels Drain Hose Assembly drain pipe clamp hose clip rubber plug amp screw Owner s Manual SPECIFICATIONS e The cooling capacity is measured at an ambient temperature of DB 95 F WB 83 F e Noise level is measured at a distance of 3 28 ft away from the front of the unit when the unit is in cooling mode e Power consumption is measured when the fan runs at the highest speed setting e These specifications are for reference only For actual data please refer to the rating label on the back of the unit e Ifthe environment temperature is higher than the max operating temperature
12. ilter by immersing it gently into warm water with a neutral detergent Rinse the filter and dry it thoroughly out of sunlight 3 Slide the filter back into the filter compartment after it is thoroughly dried 4 If the filter is torn or unusable order a new filter by calling the customer service number on the watranty page of this manual Clean the unit Housing 1 Keep the unit from being exposed directly to the sun to prevent color fading 2 Clean the surface with a damp cloth and dry it with a soft towel Storing the Unit for an Extended Period of Time or Transporting the unit 1 Empty any excess water by unplugging the water drainage stop in the back of the unit located at the bottom 2 Unplug the unit 3 The unit should be stored in a cool dry place DISCLAIMER ALL INFORMATION AND THE TECHNICAL SPECIFICATIONS PRESENTED IN THIS USER S MANUAL ARE THE PRESENTATION OF THE MANUFACTURER SOLEUS INTERNATIONAL HAS NOT CONDUCTED INDEPENDENT TEST TO THE INFORMATION AND THE SPECIFICATIONS PRESENTED HEREWITHIN 12 po S SE TROUBLESHOOTING PROBLEM POSSIBLE CAUSES SOLUTIONS The air conditioner is unplugged or not e Make sure the air conditioner plug connected well is pushed completely into the out let The Air Conditioner will not start e Check the house fuse circuit The fuse is blown circuit breaker is breaker box and replace the fuse tripped or reset the breaker e The unit will automatically re start Power
13. ion near a grounded electrical outlet and suitable window or door Remove packaging and locate components e Extend both ends of the exhaust hose approximately 6 inches e Screw the window kit adapter onto one end of the exhaust hose clockwise Screw the hose adapter onto the other end of the exhaust hose clockwise e Mount the exhaust hose onto the back of the unit by locking the hose adapters into place e For maximum efficiency do not bend the hose as much as possible SINGLE HOSE WINDOW KIT INSTALLATION Installation of the Venting Kit ea ive lato tes PRE ene FOR SINGLE HOSE PORTABLE AIR CONDITIONERS The venting kit must be installed in order for the unit to work correctly in the air conditioning mode The venting kit should not be used while the unit is heating or w Ee fanning lt L hemme The window kit has been designed to fit into most vertical AD and horizontal window openings The window kit can also C be used in a sliding door 7 1 Choose a suitable location near a grounded electrical outlet and a suitable window or door Remove packaging and locate components figure a 2 Slide the exhaust connector over the discharge opening on the back of the unit figure b 3 Connect the exhaust hose to the exhaust connector aligning the fitted grove figure c 4 Open the window or door and adjust the length of the window kit to fit the opening figure d If necessary mark the kit and cut on
14. t to reset the LCDI Plug Contact Soleus Air Powered by Gree Customer Service for trou bleshooting recommendations RESET TEST WARNING 1 DO NOT press the TEST button while the air conditioner is operating 2 The TEST and RESET buttons should not be used as ON and OFF switches 3 The cord and plug are not intended to offer protection to externally connected loads or supply circuits 4 The cord and plug are intended for indoor use only NOTE Your units power cord and plug may differ from the one shown SSS SEE ew PRODUCT DIAGRAM Control Panel TILL Le EE PP To Louvers SE E WLM A hh hhh sf LYELL VITALLY LL EL LOI Casters Power Cord Filters Upper Air Intake Lower Air Intake PARTS amp WINDOW KIT ASSEMBLY PARTS EXHAUST HOSE amp ADAPTERS Exhaust Hose Adapter sas _ gt F TA TER i TT Wood Screws 4 M Exhaust Hose med TN M EI 1 If TITI N l Adjustable Window Slider 3 Hose Adapter and Window Kit Adapter ASSEMBLY amp INSTALLATION INSTALLATION When the unit is operating as an air conditioner or dehumidifier the window kit and exhaust hose must be installed When the unit is operating in fan mode the window kit and exhaust hose do not need to be installed MOUNTING THE EXHAUST HOSE e Choose a suitable locat