Soehnle Oxygen Equipment 3010 User's Manual
Contents
1. There may be deviations on special purposes versions 1 2 Appliance description B Technical data Housing made of stainless steel protection class IP 40 or 65 integrated power adapter 100 240 VAC optional DC DC converter 12 or 24 V 2 measuring points connectable internally Membrane keyboard with a total of 10 keys 1 function key Display 7 digits 7 segment display 16 mm digit height backlit and dimmable Operating temperature 10 C to 40 C Calibratable to Precision Class Ill for n 8000e for multirange and multidivision scales Approvable weighing range 0 1 kg to 120 t e Smallest permissible input signal per calibration value 0 22 uV Load cell power supply 5 VDC Optional Alibi memory for min 2 million inputs Interfaces 2 x RS 232 additional ports optional including bus analogue output 0 20 mA USB B 13 Putting into operation Before connecting the power plug to the mains make sure that the power supply specified on the nameplate and the power plug version comply with local conditions Place the connected scales on a level and stable surface Protect the application by selecting a site of installation that is not subject to shocks vibration intensive heat or cold draughts chemicals or moi sture The appliance may only be opened by trained service technicians Before carrying out any service work on the appliance disconnect the power supply After power on the measured values s
2. switching over the weight units must be released in Calibration mode Switch over by pressing the Info key and then the Zeroing key If weight unit switchover was also assigned to the F key in Setting mode you can also switch over the unit by pressing the F key 2 5 Taring function 1 B583 BSB Akg hold f 7 058 Jk ja Manual tare Place an empty container on the platform and press the Te key Manual tare input In Setting mode see separate description 470 702 078 User Mode select Manual tare input to assign the F key Then in operation press the F key to set the value using the arrow keys G F The set value is accepted by pressing the key Tara info Press the 9 key and then the key to display the currently stored tare value Press the CL key to exit the display Clear tare Press the gt o key or the and te keys in succession Autotare function Tares the first weight value on the scale automatically Place an empty container on the platform When the platform is still the first weight value in the tare memory is accepted After clip off the tare memory is cleared automatically The Autotare function must be selected in Setting mode see separate descrip tion 470 702 078 User Mode Provisional tare function A provisional tare function can be assigned to the F key see separate
3. view print entries in Setting mode Press 9 and keys for 5 seconds until UCAL appears Press gt t key repeatedly until UCAL 5 appears Press the key to confirm Then press the key until the Setting step 03 appears Press the amp key to confirm The number of the last data record saved appears Call each data record by changing the consecutive number using the arrow keys 4 c J and display by confirming with the 9 key 10 The selected data record is displayed in scroll mode as follows Display ig 2680 a Oca A234 kg Rie Seta Meaning Consecutive number of alibi entry Scale type Year Consecutive number Gross or net with alibi ID Tare with alibi ID Serial number of mea suring point Scroll by pressing the arrow keys 2t up or down Quite the View mode by pressing the key Press the key and then hold down the and keys for 5 seconds to switch back to Weighing mode 2 9 Hold function The hold function is activated in Setting mode see separate descrip tion 470 702 078 User Mode In weighing mode activate the Hold function by pressing the F key The following Hold functions are standard on the Digital Indicator Type 301x to freeze weight data Default is O Hold mode o a A WwW N Function Not active Hold at standstill Hold at standstill Max value Max value Slave counter S
4. 0 0 2 seem Page 12 231 bEB Iamps uses rester PIRE MS HRIRREPOqee P PRPMEMHO NR ce eee deed Page 12 3 0 Application programs derreire eser RIDE Re RT ee Dd ERU RE Ru Page 13 3 4 Weighing and taring liiis RII Page 13 3 2 COUNTING sione ck ut LL EXMD DAS REEL de es dvlaw ad UE Ee s Page 13 S9 TORSO 6 eur Sue epo EU neas pati Ox a apa ma Reha dfe d el MERE da Page 14 34 Batching usce o eder er beue war umm PER edu Page 15 3 5 Withdrawal weighing sssesee RII Page 15 3 6 Switching point programming ssseeee IIR Page 16 9 7 Checking erer dtt be b Dien edd ed Page 16 3 9 DOSING iere reg CpeERMR MAU MPPPREHHN eae Sas tee ee eee Page 16 4 Troubleshooting 4 4 erai pee ae RDERIRH n re aettaddw Beas uten Page 18 Thank you for choosing this Soehnle Professional product All the features of this product were designed to the state of the art and are optimised for simple and straightforward use If you have any queries or experience any problems with the appliance that are not addressed in the operating instructions please contact your Soehnle Professional service partner or visit us on the web at www soehnle professional com 1 1 Operating manual notes a This operating manual describes all the standard functions and settings of the Basic Terminal 3010 Further information on the Setting mode is provided on the enclosed CD All the information is based on the standard version of the Basic Terminal 3010
5. FOR MEASUREABLE SUCCESS PROFESSIONAL Basic Terminal 3010 Operating Manual www soehnle professional com ENGLISH Contents 1 Introduction nerasi Ee E eem RR PRESE betes IRR RE n Page 3 14 Operating manual NOTES ere tete a iae Rege A p ad Page 3 1 2 Description of the appliance lsseseeee IR Page 3 1 3 Putting into operation sisate enata one eee gare a bacon Ed Page 4 1 4 Jnstallation 3 cesse doe ed eared CET CURED IE X EYE E Pee ce Ee reed Page 4 1 5 Symbols offcscce stated bees eres e N iei eue Di pce diae aid Page 5 1 6 Description of the nameplate 00 ee ne Page 5 1 7 Control Keys oci Rer aa a dae t edrimsd edit Page 6 18 Electronic nameplatle 2 esae ERE eden Page 7 2 0 Basic functions 1 0044 eee evi warp vetu qae o moved Page 8 271 POWERON nni xard pa a ae aa A aaao eaa aa RAS deb Page 8 2 2 Switching Off ice tse uiian idei SE e E E d ope dau d a Page 8 2 3 LOTOWNG siare e E Re d an eed init a t erar dU e d ped Page 8 2 4 Switching over the weight unit kg lt gt Ib 2 eee Page 8 2 5 Tang fUfctlolt 1er suot ete rase eed hie te a E N Page 9 2 6 Tentimes resolution X10 ssslsleseeseeee ee Page 10 2 7 Switching over the scales measuring points 0 0 eee eee eee Page 10 2 8 AlIDEMOMONY scere erm eto v dg er vga re P im Page 10 2 9 HAIG FUNCTION duco bus nter eee tremula S re ntes tO EEEE Page 11 2 10 Measuring point inputs and outputs
6. Fax 49 0 71 92 93 19 211 E Mail infoGsoehnle professional de 470 051 104 GB SCALES SYSTEM SOLUTIONS AND SPECIAL DEVELOPMENTS www soehnle professional com
7. des cription 470 702 078 User Mode Unknown tare values can be added to the existing tare value without changing the net reading Press the F key Hold appears in the display Place additional tare on the platform or remove tare from the platform Press the amp key to accept the new tare value i 2 6 Ten times resolution X10 The ten times resolution appears by pressing the 9 key and the Zeroing key simultaneously On approved scales the high resolution appears for 5 seconds or flashes as long as you hold down the keys on non approved scales the high resolution 14985 Jk appears as long as you press the key and the Zeroing key wird 4 B 2 7 Switching over the scales measuring points The Basic Terminal 3010 can operate 2 analogue measuring points pare Toggle between the measuring points by pressing the INFO key followed by i the key in succession 2 8 X Alibi memory CD The alibi memory is activated in Setting mode see separate description 470 702 078 User Mode When the alibi memory is activated an arrow points to the corresponding symbol The arrow flashes as soon as the entered limit for full indication is reached Press the amp key or data request to accept a value to the alibi memory To do this the print template or the data record must be configured accordingly see separate description 470 508 059 Data Interface Send a request to the alibi memory
8. ed individually by tapping the key briefly When you hold the key down the display increments or decrements continuously Acknowledge by pressing the key The display jumps to the next switching point Set the value using the arrow keys Press the key to confirm etc Each switching point function is defined in Setting mode see separate description 470 702 078 User Mode The switching points for the internal LED lamps or the external lamps optio nal are used for checking Enter the setpoints as check values as follows S4 Switching point Value S1 0 S2 Lower tolerance S3 Upper tolerance Upper tolerance Enter the switching points as described in 3 6 Activate in Setting mode 470 702 078 User Mode The following dosing functions can be set Coarse dosing without correction value fine dosing without correction value Coarse dosing with correction value fine dosing with correction value Coarse dosing without correction value fine dosing with correction value Fine dosing without correction value Fine dosing with correction value Select the dosing function in Setting mode see separate description 470 702 078 User Mode and 470 051 109 Dosing Use the switching points see 3 6 to set coarse flow fine flow and correction value Setting the switching points S1 Setpoint for coarse dosing S2 Setpoint for fine dosing S3 Correction value for coarse dosing S4 Cor
9. g Display Remedy Please check that you operated the appliance correctly If not interrupt the command chain by pressing the CL key n The scale sets the value zero auto Clip off the platform Possibly remove m matically when it is switched on If any soiling If the scale fails to the scale is outside the set tolerance display zero after a few seconds ple band the display indicates 0 ase inform your service partner Underload Only the lower horizontal Switch off the scale and switch it ampie mim E lines appear in the display pane back on again The zero point is reset automatically Overload Only the upper horizontal Remove part of the weighing product 2o 2 lines appear in the display pane The from the scale maximum weighing range is excee ded Er P n qd Part weight too small Er r n5 Zeroing limit overshot or undershot Not possible to tare an unloaded Er r D6 scale not possible in overload Not possible to print in underload or overload Err Err cy CJ co Switchover kg lb locked In case of other error messages please contact your service partner 18 ENGLISH nmm 9 FOR MEASURABLE SUCCESS PROFESSIONAL Soehnle Professional GmbH amp Co KG Wilhelm Soehnle Strafie 2 71540 Murrhardt Printed in Germany 04 2008 Subject to technical modifications Phone 49 0 71 92 93 19 220
10. lave counter Clear function On key Clip off On key Clip off On key Clip off 11 ENGLISH lj 2 10 Inputs and outputs The optional I O module has 4 inputs and outputs that can be individually configured in Setting mode see separate description 470 702 078 User Mode B 2 31 LED lamps The appliance has integrated LED lamps The functionality can be set and activated individually for each application program in Setting mode see separate description 470 702 078 User Mode 3 0 Application programs The various application programs on the Soehnle Basic Terminal 3010 offer you a wide range of solutions for weighing operations You can modify the application programs to your specific requirements in Setting mode see separate description 470 702 078 User Mode Below is a list of application programs available to you 3 1 Weighing and taring 3 2 Counting 3 3 Totalising 3 4 Batching 3 5 Withdrawal weighing 3 6 Switching point programming 3 7 Checking 3 8 Dosing 3 4 Weighing and taring Weighing RS The appliance starts in Weighing mode after power on 4985 Place weighing product on platform and read weight Weighing with tare a N Refer to 2 5 GOGkg An active tare weight is indicated by the letter N appearing in the display J c B 3 2 Counting The counting function is activated by pressing the Counting key The message Add XXX XXX numbe
11. r of reference parts requests you to place one or several reference parts on the platform By pressing the Counting key repeatedly you can change the reference quantity for lightweight reference parts in steps of 1 2 5 10 25 50 Place the reference parts on the platform and confirm by pressing the e key Then place the countable parts on the platform and read off the countable parts Change to Weighing mode by pressing the CL key Counting with tare Refer to 2 5 An active tare weight is indicated by the letter N appearing in the display 13 lj 3 3 Totalising a4 265w FE e 14 Displaying the piece weight Press the Info key and then the counting key to display the piece weight Press the CL key to go back Place weighing product on the platform in Weighing mode and accept the weight value in the total memory by pressing the key Remove the weighing product from the platform or dependent on the previous setting clip off In Setting mode see separate description 470 702 078 User Mode define whether the scale must be clipped off each time you place an individual piece on the platform by increments of 1 to 30 If the scale is not clipped off the weight unit is not accepted in the total memo ry This prevents operations such as saving an item twice Place the next weighing product on the platform and press the key to accept the weight value in the total memor
12. r ranges disappear Display step 1 oM o MEM Bom gt BON v a eo He 12 13 14 lo Parameter Calibration counter Type Year Serial No ID Chip Max of Range 1 Min of Range 1 e of Range 1 Max of Range 2 Min of Range 2 e of Range 2 Max of Range 3 Min of Range 3 e of Range 3 Reading InFo Eg t e880 Sa i234 ld 10 00kg and symbol for Range 1 _ 0 20kg and symbol for Range 1 E 0 01kg and symbol for Range 1 20 00kg and symbol for Range 2 _ 0 40kg and symbol for Range 2 E 0 02kg and symbol for Range 2 30 00kg and symbol for Range 3 1 00kg and symbol for Range 3 E 0 05kg and symbol for Range 3 On a non approved scale d is displayed instead of E a 2 Basic functions The basic functions are similar or identical for all application programs B 2 1 Power on Only when the scale is not loaded E After the test routine the display is set to zero The scale is ready for use Place the weighing product on the scale 4g BG The display shows the gross weight Bl 22 Switching off This is immediately possible when the display is O Otherwise hold down the key for 3 seconds 23 Zeroing Press the Zeroing key to correct minor deviations from zero e g caused by soiling on the scale Zero range approvable and non approved 1 to 3 of the weighing range 2 4 Switching over the weight unit kg lt gt Ib The option for
13. rection value for fine dosing The greatest possible switching point in the maximum scale load Dosing operation Tare the container as required Note A dosing start interlock with an untared scale must be selected in Setting mode see separate description 470 702 078 User Mode Start the dosing function by pressing the F key The dosing valve open and dosing product flows The yellow LED lights up and the display flashes until the set dosing weight is reached The green LED lights up when the dosing weight is reached and is within the tolerances The dosing valve closes The red LED lights up when the upper dosing weight tolerance is exceeded Interrupting the dosing operation Press the CL key The yellow LED lights up the display flashes and waits for the dosing operation to continue the same response takes place when the dosing product is not sufficient for a full dosing operation Press the F key to continue the dosing operation The dosing operation is also interrupted when the scale is in overload or underload When the overload or underload condition is remedied the dosing operation continues automatically Ending the dosing operation Press the CL key twice The scale is then in standard weighing mode Dosing with totalising function The totalising function during dosing must be selected in Setting mode see separate description 470 702 078 User Mode Presetting NO totalising 17 i 4 Troubleshootin
14. rification Kup Dor oeo 1 M D Precision class Sae XXXX D07 09 011 Number of EU approval XXXX e g 0103 Official Code of Notified Body this body performed the initial calibration M Symbol for EU calibration 001 Calibration counter status B17 20 3Te INFO Max Min e Control keys Operating mode On Off Zeroing key or Clear tare Tare key Print key or Enter key Clear key or Cancel key Info key Totalise or Batch Count Setpoints or corrected values Freely programmable function key Setpoint input Set input to zero Increment value Cancel key Accept setpoints or cor rected values and continue Decrement value Setting mode One menu level back or shift an editable decade from right to left Next setting step or increment value Next setting step or increment value Access edit function within setting step or save parameter and go to next setting step Go back one menu level in Setting mode Go back by one setting step or decrement value 1 8 Electronic nameplate Press the Info key twice to display the electronic nameplate Press the arrow keys to indicate the electronic nameplate the Serial No and the calibration counter of the activated measuring points in the display Press the CL key to cancel or end display of the electronic nameplate With a 1 or 2 range scale the parameters of the othe
15. rolls Gross Tare Net and Quantity Cancel or end by pressing the CL key Clear the batch memory by pressing the CL key and then the key Batching with tare Refer to 2 5 An active tare weight is indicated by the letter N appearing in the display Autobatching select function in Setting mode Place weighing product on the platform in Weighing mode and accept the weight value in the batch memory by pressing the key Place the next weighing product on the scale The weight value is automatically accepted in batch memory Place the next weighing product on the scale etc Carry out a complete configuration of the batching function in Setting mode see separate description 470 702 078 User Mode 3 5 Withdrawal weighing a Place a container with the weighing product on the platform Press the tare key Remove part of the weighing product ne The removed weight value is displayed with a negative sign P O58 Ska Press the tare key again etc 15 E 3 6 Switching point programming gt o 02 03 04 Bl 37 Checking K 3 8 Dosing 16 Four switching points can be set in the Basic Terminal 3010 The switching points are used for switching and dosing Setting the switching points Press the switching point key The first switching point is displayed This is indicated by the arrow gt in the display Set the value using the arrow keys The value is increment
16. tabilise after a warm up period of 30 minutes Pressure compensation membrane on IP 65 housing Power supply Interface 1 Ground GND Interface 2 Scale 1 2 Connections e g Profibus Ethernet etc P8 B 1 4 Installation Install the weighing platform at the point of use KO mE Using a spirit level and the adjustable feet ensure that the platform is E horizontal Install the Basic Terminal or mount it on the wall using the optional bracket Provide access to a mains power source or connect the appliance to a DC power source using a DC DC converter The scale is ready for use 1 5 Symbols pcs C J hold 0 PLI ML NPT 01 SBBBBBBB M1 lt Active measuring point scale isi Active weighing range 0 Zero reading N Net weighing T Tare reading PT Manual tare hold Hold mode The reading is fixed to improve legibility gt Total memory pcs Piece count mode CL lt Alibi memory gt 01 04 Switching points Outputs O1 O4 1 6 Description of the nameplate H en Weighing ranges Max Maximum load of weighing range OQ Min Minimum load of weighing range e Calibration value resolution SNR Serial number of scale scale type last digits of year Mex eee ee ee of manufacture consecutive number Min Zr EI C 08 EU conformity mark with year of affixing also start of SNR XXXXIXX XXX C 08 validity of ve
17. y etc A full total memory is recognised by the totalising character X Call up the total value by pressing the Info key and then the key The display then scrolls Gross Tare Net and Quantity Cancel or end by pressing the CL key Clear the total memory by pressing the CL key and then the key Totalising with tare Refer to 2 5 An active tare weight is indicated by the letter N appearing in the display Autototalising select function in Setting mode Place weighing product on the platform in Weighing mode and accept the weight value in the total memory by pressing the key Remove weighing product from the platform Place the next weighing product on the scale The weight value is automatically accepted in the total memory Remove the weighing product from the platform and place the next weighing product etc Carry out a complete configuration of the totalising functions in Setting mode see separate description 470 702 078 User Mode 3 4 Batching E Place weighing product on the platform in Weighing mode and accept the weight value in the batch memory by pressing the key Place the next weighing product on the platform and press the key to accept the weight value in the batch memory etc 28565 A full batch memory is recognised by the totalising character in the kg display lt Call up the total value by pressing the Info key and then the key The display then sc