1. dimensions are minimum clearances Grounded electrical supply is required See Electrical Requirements section Proper gas supply connection must be available See Gas Supply Requirements section To prevent accidents or ruining the mobile components of the appliance the following steps must be taken before performing the procedures described below Remove all packaging parts e g crate carton polystyrene and metal hooks Do not eliminate this manual as it is an integral part of the appliance and it should be kept handy for easy reference whenever needed Temporarily remove all removable parts from the cooktop that could fall and cause personal injury or damage to objects burners crowns and flame caps during the attachment procedures These parts must be refitted before using the appliance The measurements supplied in the tables referring to the figure below must be followed when attaching the appliance to the support structure Instructions for the Installer CEN Cooktop MINIMUM DISTANCE widhi SS ES a A 23 Se 22 22 K 6 18 Ip 19 8 Ue 3 vee 1 m 6 13 46 1 oe 6 23 Wee 600 mm 560 570 mm 478 482 mm 210mm 86mm 36 mm 20 40 mm 600 mm 39 7 5 33 46 33 Vg 19 4yq 19 qq 4 ye 1 yg 18 46 1 Fie 39 3 g 1000 mm 855 860 mm 485 490 mm 210mm 112mm 36mm 20 40 mm 1000 mm Gas line opening Wall everywhere 5 12 7 cm below underside of countertop Cabinet base
2. 106 NEUTRAL 120 VAC 60Hz WIDE BLADE N 7 WIDE BLADE GROUND 6 1 PHASE 15 O 20 AMP ROUND BLADE BLACK WHITE GREEN OR GREEN YELLOW SUPPLY TERMINALS RED BLUE S1 52 SWITCHES SPARK MODULE ELECTRIC CIRCUIT CLOSED WHEN KNOB IS PRESSED TRANSPARENT 6 PLACES INGITOR i 1 T ELECTRODES H HK Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing 17
3. LUG PU 64 LINE NEUTRAL 120 VAC 60Hz WIDE BLADE N WIDE BLADE 1 PHASE GROUND P 15 O 20 AMP ROUND BLADE N BLACK WHITE GREEN OR GREEN YELLOW SUPPLY L N TERMINALS RED BLUE S1 o o SWITCH ELECTRIC CIRCUIT CLOSED WHEN KNOB SPARK IS PRESSED MODULE TRANSPARENT 4 PLACES INGITOR i ELECTRODES Label all wires prior to disconnection when servicing controls WARNING Wiring errors can cause improper and dangerous operation Verify proper operation after servicing 15 CEN Instructions for the Installer The power cord on this appliance is equipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles PLUG PU 75 WERE g T Pa 120 VAC 60Hz 1 PHASE UND BLA i 15 O 20 AMP ROUND BLADE N BLACK WHITE lt GREEN OR GREEN YELLOW SUPPLY LILIN TERMINALS aeons RED BLUE S1 Q Q SWITCH ELECTRIC CIRCUIT CLOSED WHEN KNOB SPARK IS PRESSED MODULE TRANSPARENT 5 PLACES INGITOR 1 1 1 1 1 ELECTRODES Label all wires prior to disconnection when servicing controls Wiring errors can cause improper and dangerous operation Verify proper operation after servicing 16 Instructions for the Installer A N I PLUG The power cord on this appliance is equipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles LINE PU
4. Onm O o1 e Table of Contents IMPORTANT SAFETY INSTRUCTIONS 2 0 0 ccccccccececeeeeeeeeeeeeeeeeteeeteeeeeeeeaueeeeesaeeseeeteneenaeess 4 s COOR TOP MEASUREMENTS iorsin reene E a ear 5 POSITIONING THE COOKTOP AND LOCATION REQUIREMENTS ec eeeceeeeeeeee eee 6 3 1 Gas SUDDIY FEGQUIFGINCINS ss vscse cesses oes isn eae aiea ENEE E EEEE EEA AAEE a E 8 3 2 Electrical requirements ccccceccceecceeeceeecceeeceeceaecceeeceeceuecsueeseeseeeseesseeseeeeaeeseeessueesaeesseeseueesaeesaeesaesseesaas 9 ANSTALCLING THE COOKTOP aria A EEN 11 pe RU IN OFE RATON cata sitsac strc ecntrettnalavt E E E E N 14 5 WIRING DIAGRAMS centacircaistioncnaresssdaeisaneass a aE E N 15 INSTRUCTIONS FOR THE INSTALLER these are intended for the qualified engineer who is able to install commission and test the appliance X Important Safety Instruction 1 IMPORTANT SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS Your Safety And the Safety of Others Are Very Important We have provided many important safety messages throughout this manual and on your appliance Read all instructions before using your appliance and always obey all safety messages RECOGNIZE SAFETY INFORMATION This is a safety alert symbol This symbol alerts you to potential hazards that can kill or hurt you and others UNDERSTAND SIGNAL WORDS A signal word DANGER WARNING or CAUTION is used with the safety alert symbol DANGER identifies the most ser
5. everywhere within 6 15 2 cm from rear wall is recommended Grounded outlet X Locate within 24 61 cm from the right rear corner of the cut out drawer 1 2 3 Instructions for the Installer 3 1 Gas supply requirements EXPLOSION HAZARD Use anew AGA or CSA approved gas supply line Install a shut off valve Securely tighten all gas connections If connected to LP have a qualified technician ensure that gas pressure does not exceed a 14 water column Examples of qualified technicians include licensed heating personnel authorized gas company personnel and authorized service personnel Failure to do so can result in death explosion or fire NOTE observe all government codes and ordinances The cooktop must be connected to a regular gas supply This installation must conform to local codes and ordinances In the absence of local codes installations must conform to American National Standards National Fuel Gas Code ANSI 2223 1 latest edition or CANI 13149 1 or 2 If local codes permit a flexible metal appliance connector with the new AGA or CSAcertified design 4 5 feet 1 2 1 5 m long 1 2 or 3 4 D is recommended for connecting this cooktop to the gas supply line Do not bend or damage the flexible connector when moving the cooktop The pressure regulator has 3 8 female pipe threads You will need to determine the fittings required depending on the size of your ga
6. gas supply piping system at test pressures equal to or less than 1 2 psig 3 5 kPa If the appliance is installed on an oven the gas pipe must not pass ce ci along the back of the oven as this may cause overheating 6 3 2 Electrical requirements ELECTRICAL SHOCK HAZARD Plug into a grounded 3 prong outlet A WARNING Do not remove ground prong ily Donot use an adapter Do not use an extension cord Failure to follow these instructions can result in death fire or electrical shock lf codes permit and a separate ground wire is used it is recommended that a qualified electrician checks that the ground path is adequate Check with a qualified electrician if you are not sure whether the cooktop is properly grounded Do not ground to a gas pipe A 120 volt 60 Hz AC only 15 ampere fused electrical supply is required A time delay fuse or circuit breaker is recommended It is recommended that a separate circuit serving only this appliance be provided 10 Instructions for the Installer 3 2 1 Recommended Grounding Method For your personal safety this cooktop must be grounded This cooktop is equipped with a 3 prong ground plug To minimize possible shock hazard the cord must be plugged into a mating 3 prong ground type outlet grounded in accordance with the National ANSI NFPA 70 Electrical Code latest edition or the Canadian Electrical Code CSA and local codes and ordinances If a
7. ious hazards It means you can be killed or seriously injured if you do not immediately follow instructions WARNING means you can be killed or seriously injured if you do not follow instructions CAUTION indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury All safety messages will inform you as to potential hazards inform you on how to reduce the risk of injury and as to what can occur if the instructions are not followed IMPORTANT Observe all government codes and ordinances WARNING For your safety the information in this manual must be followed to minimize the risk of fire or explosion or to prevent property damage personal injury or death Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance WHAT TO DO IF YOU SMELL GAS Do not attempt to switch on any appliances Do not touch any electrical switches Do not use any phones in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a qualified installer service agency or the gas Supplier NOTE This cooktop is manufactured for use with Natural gas To convert to LP Propane gas see of instructions in the Gas Conversion Kit provided in the literature package Proper gas supply connec
8. mating outlet is not available it is the personal responsibility and obligation of the customer to have a properly polarized and grounded 3 prong outlet installed by a qualified electrician Copies of the standards listed above may be obtained from National Fire Protection Association One Batterymarch Park Quincy Massachusetts 02269 CSA International 850 1 East Pleasant Valley Rd Cleveland OH 44131 5575 1 2 3 4 Instructions for the Installer CEN 4 INSTALLING THE COOKTOP Remove the upper polystyrene guard and the side guards Remove the grids the nylon sheet serving to protect the cooktop during shipping and the burner crowns These parts could make product assembly more difficult Connection to the gas mains may be made with a flexible metal pipe and conforming to the provisions defined by current standard regulations in force USE A SOAPY SOLUTION TO CHECK FOR PROPER TIGHTNESS NEVER USE A FLAME The following procedures must be performed to adjust the gas supply pressure for LP operation of the cooktop 1 Unscrew cap A on the pressure regulator 2 Turn itto the part where LP is printed 3 Re tighten it and lock the pins in the slots provided 4 There is an arrow printed on the back of the energy regulator The tip of the arrow indicates the end to be connected to the cooktop connector Carefully position the insulation gasket supplied on the external perimeter of the hole fo
9. okes in the special A seats found on the cooktop These procedures must be repeated for each burner on the cooktop CAUTION refit all flame caps in the same points from which they were removed In fact the flame cap positions cannot be changed After refitting them ensure that they are fitted perfectly and that there is no clearance between the top and the flame caps The cooktop s electrical circuit can be checked for proper operation only after top assembly has been completed as described in step 2 and you have checked to ensure that all parts have been fitted properly 1 a spark must light on all burners when the knobs on the top are pressed JA 3 2 when each knob on the cooktop is pressed and turned to the OPUSH min flame symbol the entire crown should light 3 If burners do not light properly turn the control knob to the 6 E OFF position Check that burner caps and crowns are in the proper position Check that the power supply cord is plugged in and that circuit breaker or house fuse has not blown Check that the shut off valve is in the ON position Check operation again If a burner does not light at this point contact your dealer for assistance 14 Instructions for the Installer CEN D 6 WIRING DIAGRAMS The power cord on this appliance is equipped with a threee pronge polarized plug grounding which mates with standard three pronged grounding wall receptacles P
10. pipe E If flexible metal conductor is used be certain tubing is not kinked Use only pipes E conforming to standard regulations in force 7 inserting gasket B supplied between fitting A adaptator C The adaptor C must be fitted on the gas connection A before fixing the hob Always place a suitable sealing medium such as Teflon tape between pressure regulator D and adaptator C and between pressure regulator D and pipe E 8 Plug power supply cord into grounded outlet 13 Instructions for the Installer 5 CHECKING OPERATION After having fastened the top to the support structure some simple procedures are required to check for proper operation 1 Check for any gas leaks in the vicinity of the cooktop connector the pressure regulator and the safety valve FIRE HAZARD A WARNING Use a soapy solution to check for proper tightness ye Never test for gas leaks with a match or other flames XK Failure to follow this instruction can result in death or fire NOTE The regulator Is fitted with a checkpoint outlet gas pressure to check the exact pressure supplied of to the appliance Refit the crowns flame caps and grids on the cooktop in the following order 1 Fit the crowns ensuring that they are perfectly locked into their housing on the cooktop 2 Fit the flame caps on the crowns ensuring that the edges match perfectly 2 3 Fit the grids making sure to fasten the side sp
11. s supply line the flexible metal connector and the shut off valve The supply line shall be equipped with an approved shut off valve This valve should be located in the same room as the cooktop and should be in a location that allows for easy opening and closing Do not block access to the shut off valve The valve is necessary for turning the gas to the appliance on or off Shutoff Valve open position To Cooktop Gas Supply Line Instructions for the Installer The regulator must be checked at a minimum water column of at least 1 2 5 cm above the set pressure The inlet pressure to the regulator should be as follows for operation and monitoring of 4 the regulator setting NATURAL GAS Set pressure at 6 15 2 cm Supply pressure 7 14 17 8 cm to 35 5 cm maximum LP GAS Minimum pressure of 10 25 4 cm Supply pressure 14 35 5 cm Line pressure testing Testing above 112 PSI 3 5 kPa with water column of 14 35 6 cm gauge The cooktop and its individual shut off valve must be disconnected from the gas supply piping system during any pressure testing of that system at test pressures greater than 1 2 psig 3 5 kPa 5 Testing below 112 PSI 3 5 kPa with a water column of 14 35 6 cm gauge or lower The cooktop must be isolated from the gas supply piping system by closing the respective manual shut off valve during any pressure testing of the
12. tion must be available See Gas supply requirements In the State of Massachussets the following installation instructions apply Installations and repairs must be performed by a qualified or licensed contractor plumber or gasfitter qualified or licensed by the State of Massachusstets lf using a Ball valve it shall be T handle type A flexible gas connector when used must not exceed 3 feet Instructions for the Installer CEN 2 COOKTOP MEASUREMENTS Instructions for the Installer 3 POSITIONING THE COOKTOP AND LOCATION REQUIREMENTS NOTE The following operation requires building and or carpentry work and must therefore be carried out by a competent technician Installation can be carried out on various material such as masonry metal solid wood plastic laminated wood etc As long as they are heat resistant T 90 C 194 F Observe all governing codes and ordinances Do not obstruct flow or combustion and ventilation air It is the installer s responsibility to comply with installations guidelines specified on the model serial rating plate The model serial rating plate is located on the underside of the cooktop burner box The cooktop should be installed in a location away from strong draft areas such as windows doors and strong heating vents or fans All openings in the wall or floor where cooktops is to be installed must be sealed Cabinet opening dimensions that are shown must be used Given
13. und on the top surface see figures below and try to make it stick to the entire surface by applying light pressure with your hands Refer to the distances shown in the figure for the model to be installed keeping in mind that for both models the long front side has to skim the hole gt D 23 6 600mm 27 5 700mm _ 39 4 1000 mm A B C D 5 16 2 11 16 9 16 2 15 16 8 mm 68 mm 15 mm 75 mm 11 5 Instructions for the Installer Secure the cooktop to the counter with brackets A supplied Carefully trim any excess from edge B on the gasket The distances in the following drawing refer to the hole on the inner side of the gasket The diagram below shows the exact positions of the holes to be used for clamping the hob to the top by the brackets correctly Sf NOTE Use all of the brackets supplied with the appliance to fasten it to the support structure 12 To Cooktop Use pipe joint compound made for use with NATURAL and L P Shutoff Valve gas If flexible metal connector is used be certain tubing is not open position kinked Gas Supply Line Instructions for the Installer CEN Always use pipe joint compound made for use with NATURAL GAS and L P GAS between pressure regulator D and adaptator C and between pressure regulator D and