Home
Smeg GKC955 Instruction Manual
Contents
1. ISO 228 1 Connection with rigid copper pipe the connection to the gas mains must not provoke stress of any kind on the hob Connection may be made by using biconical adapter D with insertion of gasket C supplied Connection with flexible pipe use only flexible pipes conforming to standard regulations in force inserting gasket C supplied between fitting A and flexible pipe E The flexible pipe has to be installed so that pipe length does not exceed 1 5 meters of maximum extension Make sure that the pipes do not touch any moving parts or become damaged Instructions for the installer 4 1 Connection to LPG Use a pressure regulator and make the connection to the tank according to the provisions of standards regulations in force Make sure that feed pressure conforms to the levels shown in the table in paragraph 5 2 Regulation for LPG 4 2 Ventilation of rooms The hob may be installed only in rooms with permanent ventilation as required by standards regulations in force The room in which the hob is installed must have sufficient air flow to satisfy the requirements of normal gas combustion and of necessary air exchange in the room The air intakes protected by screens must be appropriately sized regulations in force and placed so as not to be blocked in any way The room where the oven is installed should be suitably ventilated to avoid overheating or excess humidity produced by cooking and
2. the wire section on the new cable must not be less than 1 5 mm 3 x 1 5 cable keeping in mind that the end to be connected to the hob must have the ground wire yellow green longer by at least 20 mm Use only HO5V2V2 F cable or similar which has a maximum temperature of 90 C Any replacement needed should be carried out by a specialised technician who should make the mains connections according to the following diagram L brown N blue D yellow green m Tomm The manufacturer will not be liable for any damage to persons or property caused by non observance of the above instructions or deriving from the tampering of even a single part of the hob 25 26 Instructions for the installer X 4 GAS CONNECTION Connection to the gas mains may be made with a rigid copper pipe or with a flexible pipe and conforming to the provisions defined by standard regulations in force To facilitate connection fitting A on the rear of the appliance may be adjusted laterally For this purpose loosen hexagon nut B turn fitting A to the desired position and retighten hexagon nut B tightness is ensured by a biconical brass ring Use a soapy solution to check for proper tightness Never use a free flame The hob has been inspected for G25 2L at a pressure of 25 mbar For use with other types of gases see Section 5 ADAPTATION TO DIFFERENT TYPES OF GAS The gas intake fitting is 1 2 gas external threaded
3. to the outer burner Double crown burners comprise an auxiliary and a rapid burner controlled by two different knobs which permit to use both burners at the same time or to select one or the other as required The device is fit with electronic ignition Simply press and simultaneously turn the knob counter clockwise on the low point flame symbol until the burner is ignited Concerning models with valves push the knob for approximately 2 seconds in order to keep the flame burning and to activate the safety device The burner might go off when the knob is released In this case repeat the aforesaid operation keeping the knob pressed for more than 2 seconds Should the burners go off accidentally in the models with valves a safety device will trip after approximately 20 seconds to block the gas outlet even if the tap is open 33 34 Instructions for the user 7 2 Practical advice for using the burners For better burner performance and minimum gas consumption flat bottomed even recipients must be used gx with covers and proportional in size to the burners see azz paragraph 7 3 Diameter of containers s To avoid overcooking or damage to the surface top while cooking all recipients or griddles must be positioned within the cooking hob perimeter and must be a minimum distance of 3 4 cm from the knobs m Na Wd 7 7 3 Diameter of containers Burner min and max in cm 1 Auxiliary
4. 12 14 2 Semi rapid 16 24 3 Rapid 22 26 4 Double crown 12 30 For burner reference numbers see page 32 7 4 Using a griddle plate A few precautions are necessary if you wish to use a griddle plate leave a gap of at least 160 mm between the edge of the griddle plate and the side wall if one of the burners close to the wooden rear wall is of triple flame type leave a gap of at least 160 mm between this wall and the edge of the griddle plate do not allow the burner flames to extend beyond the edge of the griddle plate operate the burners underneath the griddle plate for 10 minutes at maximum power then turn them down to the minimum setting Never use the griddle plate for more than 45 minutes S y k A Instructions for the user 8 LEANING AND MAINTENANCE Before any intervention disconnect the power supply of the device 8 1 Cleaning Clean the cooking top regularly every time you use it obviously after it has cooled 8 1 1 Regular daily cleaning of the hob In order to clean and preserve the surface always use specific products only which do not contain abrasive substances or chlorine based acid substances How to use pour the product on a damp cloth and wipe the surface rinse thoroughly and dry with a soft cloth or deerskin 8 1 2 Food stains or residues Do not use metallic sponges or sharp scrapers they will damage the surface Use normal non abrasive products and remove spots o
5. 2 Regulation for LPG Instructions for the installer X 5 2 Regulation for LPG Loosen screw A and push support B all the way Use a double head wrench to remove nozzle C and assemble the suitable one following the instructions indicated in the reference charts with respect to the type of gas to use The screwing torque of the nozzle should never exceed 3 Nm Reposition support B so that nozzle C is covered perfectly Move the Venturi tube D to regulate the air flow until distance X is reached indicated in the chart in paragraph 5 4 Regulation of primary air and then secure the tube by means of screw A After the regulations have been carried out restore the seals with sealing wax or equivalent material Rated Burner heating LPG G30 G31 30 30 mbar capacity kW Nozzle By pass Reduced Flowrate diameter mm flowrate g h G30 1 100 mm 1 100 W Auxiliary 1 1 05 48 30 33 380 76 Semi rapid 2 1 65 62 30 33 380 120 Rapid 3 3 1 85 43 45 750 224 BOBEN internal 4 1 15 48 30 ESO 380 76 external 4 3 8 92 55 1200 282 By pass value for valveless appliances 29 Instructions for the installer X 5 3 Regulation for G25 25 mbar The hob has been inspected for G25 2L at a pressure of 25 mbar To allow the unit to work with this type of gas perform the same operations described in paragraph 5 2 Regulation for LPG but choose the nozzles and regulate the primary air for natural gas as sho
6. CNL Contents 1 INSTRUCTIONS FOR SAFE AND PROPER USE 21 2 POSITIONING OF HOB 23 3 ELECTRICAL CONNECTION 25 4 GAS CONNECTION 26 5 ADAPTATION TO DIFFERENT TYPES OF GAS 28 6 FINAL OPERATIONS 31 7 USING THE HOB 33 8 LEANING AND MAINTENANCE 35 THESE INSTRUCTIONS ARE VALID ONLY FOR END USER COUNTRIES WHOSE IDENTIFICATION SYMBOLS APPEAR ON THE COVER OF THIS MANUAL INSTRUCTIONS FOR THE INSTALLER these are for the qualified technician who must carry out a suitable check of the gas system install the appliance set it functioning and carry out an inspection test INSTRUCTIONS FOR THE USER these contain user advice description of the commands and the correct procedures for cleaning and maintenance of the appliance 20 1 Introduction 1 INSTRUCTIONS FOR SAFE AND PROPER USE THIS MANUAL IS AN INTEGRAL PART OF THE APPLIANCE AND THEREFORE MUST BE KEPT IN ITS ENTIRETY AND IN AN ACCESSIBLE PLACE FOR THE WHOLE WORKING LIFE OF THE COOKING HOB WE ADVISE READING THIS MANUAL AND ALL THE INSTRUCTIONS THEREIN BEFORE USING THE COOKING HOB ALSO KEEP THE SERIES OF NOZZLES SUPPLIED INSTALLATION MUST BE CARRIED OUT BY QUALIFIED PERSONNEL IN ACCORDANCE WITH THE REGULATIONS IN FORCE THIS APPLIANCE IS INTENDED FOR DOMESTIC USES AND CONFORMS TO CURRENT REGULATIONS IN FORCE THE APPLIANCE HAS BEEN BUILT TO CARRY OUT THE FOLLOWING FUNCTIONS COOKING AND HEATING UP OF FOOD ALL OTHER USES ARE CONSIDERED IMPROPER THE MANUFACTURER D
7. ECLINES ALL RESPONSIBILITY FOR IMPROPER USE DO NOT LEAVE THE PACKING IN THE HOME ENVIRONMENT SEPARATE THE VARIOUS WASTE MATERIALS AND TAKE THEM TO THE NEAREST SPECIAL GARBAGE COLLECTION CENTRE IT IS OBLIGATORY FOR THE ELECTRICAL SYSTEM TO BE GROUNDED ACCORDING TO THE METHODS REQUIRED BY SAFETY RULES THE PLUG TO BE CONNECTED TO THE POWER CABLE AND THE SOCKET MUST BE THE SAME TYPE AND MUST CONFORM TO CURRENT REGULATIONS THE SOCKET MUST BE ACCESSIBLE AFTER THE APPLIANCE HAS BEEN BUILT IN NEVER UNPLUG BY PULLING ON THE CABLE IMMEDIATELY AFTER INSTALLATION CARRY OUT A BRIEF INSPECTION TEST OF THE COOKING HOB FOLLOWING THE INSTRUCTIONS BELOW SHOULD THE APPLIANCE NOT FUNCTION DISCONNECT IT FROM THE SUPPLY AND CALL THE NEAREST TECHNICAL ASSISTANCE CENTRE NEVER ATTEMPT TO REPAIR THE APPLIANCE ALWAYS CHECK THAT THE CONTROL KNOBS ARE IN THE POSITION ZERO OFF WHEN YOU FINISH USING THE HOB 21 Introduction s THE IDENTIFICATION PLATE WITH TECHNICAL DATA SERIAL NUMBER SAND MARKING IS CLEARLY VISIBLE UNDER THE CASING THE PLATE ON THE CASING MUST NOT BE REMOVED BEFORE CONNECTING THE DEVICE MAKE SURE THAT IT HAS BEEN REGULATED FOR THE TYPE OF GAS THAT WILL FEED IT CHECKING THE LABEL UNDER THE CASING DO NOT PUT PANS WITHOUT PERFECTLY SMOOTH AND FLAT BOTTOMS i ON THE COOKING HOB GRIDS DO NOT USE RECIPIENTS OR GRIDDLE PLATES THAT EXTEND BEYOND THE EXTERNAL PERIMETER OF THE HOB THE HOB IS TO BE USED BY ADULTS ONL
8. Y DO NOT LET UNSUPERVISED CHILDREN PLAY WITH THE HOB REPLACED APPLIANCES MUST BE TAKEN TO A SPECIAL GARBAGE COLLECTION CENTRE The manufacturer declines all responsibility for damage to persons or things caused by non observance of the above prescriptions or by interference with any part of the appliance or by the use of non original spares 22 Instructions for the installer 2 POSITIONING OF HOB The following operation requires building and or carpentry work so must be carried out by a competent tradesman Installation can be carried out on various materials such as masonry metal solid wood or plastic laminated wood as long as they are heat resistant T 90 C NEVER USE SILICONE OR OTHER INSULATING PRODUCTS WHEN INSTALLING THE APPLIANCE USE ONLY THE RUBBER GASKET PROVIDED 2 1 1 Attachment to support structure Create an opening with the dimensions shown in the figure in the top surface of the counter keeping a minimum distance of 50 mm from the rear border This appliance can therefore be mounted against walls higher than the work surface on condition that a certain distance X be kept between the appliance and the wall as shown in the figure so as to avoid damage from overheating Make sure there is a minimum of 750 mm between the hot plate flames and any shelf that may be installed directly above them Accurately position the gasket provided all around the outer edge of the hole in the top surface as s
9. hown in the figures below pressing it down so as to make it adhere properly For measurements refer to the figure depending on the hob model to be installed bearing in mind that in both models the front and rear sides must skim the hole Secure the hob to the counter with brackets A supplied Carefully trim any excess from border B of the gasket The distances in the following drawing refer to the hole on the inner side of the gasket 23 CNL 24 Instructions for the installer In case of installation on a hollow compartment with doors a separating panel has to be placed under the hob Keep a minimum distance of 10 mm between the bottom of the unit and the panel surface The panel has to be easily removable to allow access in the event of technical service A Instructions for the installer 3 ELECTRICAL CONNECTION Make sure that the voltage and capacity of the power line conform to the data shown on the plate located under the casing Do not remove this plate for any reason The plug on the end of the supply cable and the wall socket must be the same type and conform to the current electrical system regulations Check that the power line is adequately grounded On the power line install an omnipolar cut off device with contact cut off distance greater than or equal to 3 mm located in an easily accessible position near the unit Do not use reducers adapters or shunts If the power cable is replaced
10. in the case of lengthy use a window should be opened or the speed of any ventilators should be increased 4 3 Discharge of combustion products Discharge of combustion products must be guaranteed by means of hoods connected to a natural draught flue with certain efficiency or by means of forced aspiration An efficient aspiration system requires careful planning by a specialist capable of installing it respecting the positions and distances prescribed by standards After installation the installer must issue a certificate of conformity Installation of an oven without cooling fan underneath the hob is forbidden 27 CNL 28 Instructions for the installer X 5 ADAPTATION TO DIFFERENT TYPES OF GAS Before performing any cleaning or maintenance work detach the appliance from the electrical socket The hob has been inspected for G25 2L at a pressure of 25 mbar For functioning with other types of gas the nozzles must be replaced and the primary air adjusted To replace the nozzles and regulate the burners you have to remove the top as described in the following paragraph 5 1 Removing the hob 1 Remove all the knobs the grids the burner caps and the flame caps 2 remove the screws and the nuts A that secure the burner supports 3 remove plates B 4 lift the hob from its seat 5 replace the burner nozzles in accordance with the reference gas chart 6 regulate the primary air as described in paragraph 5
11. nimum for LPG completely tighten clockwise the screw inside or next to the gas tap pin depending on the model The diameters of the by passes for each burner are given in table 5 2 Regulation for LPG After having regulated the device with gas other than the one tested replace the label located on the guard with the one that corresponds to the new gas The label is inside the bag that contains the nozzles provided 31 CNL Instructions for the installer X 6 3 Arrangement of burners on hob BURNERS 1 Auxiliary 2 Semi rapid 3 Rapid 4 Double crown 6 4 Lubrication of gas taps bn i After a while the gas tap may become hard to turn or lock If this gt happens it has to be cleaned inside and re greased This must be done by a qualified technician 32 x Instructions for the user 7 USING THE HOB Before turning on the burners make sure that the burner rings caps and grids have been fitted correctly In the ultrarapid burner notch A must be aligned with pin B 7 1 Ignition of the burners Raised indicators make for easier and clearer reading and use of the controls each knob being connected to its corresponding burner by a rib Setting corresponds to the elongated part of the knob or to the marking on it Only where applicable Double crown burners controlled by two knobs feature two ribs a long one corresponding to the small inner burner and a short one
12. r residuals with non scratch sponges or if need be with wood or plastic utensils A Rinse thoroughly and dry with a soft cloth or deerskin 8 2 Cleaning of cooking hob components Grids caps flame cap crowns and burners can be removed for ease of cleaning Wash them in warm water using a non abrasive detergent taking care to remove all tough spots Before remounting allow the components to fully dry out CAUTION do not wash these components in a dishwasher 35 36 Instructions for the user 8 2 1 Ignition plugs and safety devices For good functioning of the lighting ignition plugs and the safety devices keep them very clean Check frequently and clean with a damp cloth when necessary 8 2 2 The electric element After use to make sure that the surfaces are clean and long lasting the electric element must be treated with specific cleaning products which are available on the market This necessary operation prevents oxidisation rust formation 8 2 3 The cover Clean the glass or steel cover where mounted with warm water Never use abrasive sponges or detergents To clean the rear part of the cooktop remove the cover by lifting out When finished cleaning refit the cover making sure to insert it correctly Before lifting up the cover dry out properly Never lower the cover when burners or electric elements are on or still hot
13. wn in the following table and in paragraph 5 4 Regulation of primary air After the regulations have been carried out restore the seals with sealing wax or equivalent material Rated heating Burner capacity G25 25 mbar kW Nozzle diameter Reduced flowrate 1 100 mm W Auxiliary 1 1 05 76 380 Semi rapid 2 1 65 98 380 Rapid 3 3 1 130 750 Double crown internal 4 1 05 76 380 internal 4 3 9 150 1200 30 5 4 Regulation of primary air Referred to distance X in mm G25 G30 G31 aerate 25 mbar 30 30 mbar Auxiliary 1 1 5 2 0 Semi rapid 2 1 5 2 0 Rapid 3 2 0 9 0 internal 4 3 0 6 0 Double crown external 4 3 0 10 0 For burner reference numbers see page 32 X d Ne XY FN oo Instructions for the installer 6 FINAL OPERATIONS Having carried out the above adjustments reassemble the appliance following backwards the instructions in paragraph 5 1 Removing the hob 6 1 Regulation of minimum for natural gas Replace the components on the burner and slide the knobs on the gas tap pins Light the burner and set it at minimum position Remove the knob and turn the regulation screw inside or next to the gas tap pin depending on the model until you get a suitable minimum flame Replace the knob and check burner flame stability rapidly turning the knob from maximum to minimum position the flame should not go out 6 2 Regulation of minimum for LPG To regulate the mi
Download Pdf Manuals
Related Search
Related Contents
Tractor Articulado 9430 Motor Modelo Sistema de KMEye Sony PCV-RX740 Safety Information Copyright © All rights reserved.