Home
SMC Networks SMC6405TX User's Manual
Contents
1. TABLE OF CONTENTS TABLE OF CONTENTS Description of Hardware 1 Features and Benefits 1 Front Panel EDS 4444 04 we aa diet TES 2 Side Panel RJ 45 POTS vr 2 mue dti See ok a PE SERA gs 3 Rear and Bottom Panel Tracks 3 Installing the Switch 4 Equipment Checklist 4 Selecting ASE 2 4 ne ieee ana db bide boa ae ox 5 Instr ctiofis tn ar acd ac ee Meines XM an an EUR d 6 Sample Application xs 5 34 2 8 oe 9 vx 24 PR RE rune REGES 7 Troubleshooting 8 Cables edi cide Rata didn AE le Deals OE IAS E RSS 9 Cable Specifications see LEA ea a 9 Twisted Pair Cable and Pin Assignments 9 10BASE T 100BASE TX Pin Assignments 10 Connectivity Guidelines 11 Specifications 44 2425 Aa 12 EZ Switch 10 100 SMC6405TX 12 TABLE OF CONTENTS vi DESCRIPTION OF HARDWARE DESCRIPTION OF HARDWARE The EZ Switch 10 100 SMC6405TX is a 5 port Fast Ethernet switch Its 5 10BASE T 100BASE TX ports deliver dedicated 10 100 Mbps links to each attached LAN segment all with conventional cabling and adapters Auto negotiation is used to select the optimal transmission speed and communication mode for each connection With store and forward switching and flow control maximum data integrity is a
2. lt I5FRABEHBEN BETT COMB RRR TEATATI FRBMELTOETA COMBAT DA 6T LED 2 LS EMILE LT BAHENZEREBELZIERIFLIENBHUETF NU IRL VENISE gt TEL URYRUALTESEL Australia AS NZS 3548 1995 Class B ACN 069 351 613 SMC contact for products in Australia is SMC Communications Pty Ltd Suite 18 12 Tryon Road Lindfield NSW2070 Phone 61 2 94160437 Fax 61 2 94160474 Safety Compliance CSA NRTL C22 2 950 UL 1950 EN60950 IEC 950 il COMPLIANCES Wichtige Sicherheitshinweise Germany 1 2 3 Un 10 11 12 13 14 15 Bitte lesen Sie diese Hinweise sorgf ltig durch Heben Sie diese Anleitung f r den sp teren Gebrauch auf Vor jedem Reinigen ist das Ger t vom Stromnetz zu trennen Verwenden Sie keine Fl ssigoder Aerosolreiniger Am besten eignet sich ein angefeuchtetes Tuch zur Reinigung Die Netzanschlu steckdose soll nahe dem Ger t angebracht und leicht zug nglich sein Das Ger t ist vor Feuchtigkeit zu sch tzen Bei der Aufstellung des Ger tes ist auf sicheren Stand zu achten Ein Kippen oder Fallen k nnte Besch digungen hervorrufen Die Bel ftungs ffnungen dienen der Luftzirkulation die das Ger t vor berhitzung sch tzt Sorgen Sie daf r daf diese Offnungen nicht abgedeckt werden Beachten Sie beim Anschlu an das Stromnetz die Anschlu werte Verlegen Sie die Netzanschlu leitung so da niemand dar ber fallen kann Es sollte auch nichts auf der Leitung abgest
3. EZ Switch 10 100 5 Port Fast Ethernet Switch 5 auto MDIX ports Connect to PCs or other hubs and switches Auto negotiation of speed and duplex mode Plug and play nothing to configure no crossover cables required Full duplex support on all ports Half and full duplex flow control Compact size with versatile mounting stand 90 SMC ar Networks EZ Switch 10 100 User Guide From SMC s EZ line of low cost workgroup LAN solutions SMC Networks 6 Hughes February 2001 Irvine CA 92618 Phone 949 707 2400 Pub 150620 102 ROI Information furnished by SMC Networks Inc SMC is believed to be accurate and reliable However no responsibility is assumed by SMC for its use nor for any infringements of patents or other rights of third parties which may result from its use No license is granted by implication or otherwise under any patent or patent rights of SMC SMC reserves the right to change specifications at any time without notice Copyright 2001 by SMC Networks Inc 6 Hughes Irvine CA 92618 All rights reserved Printed in Taiwan Trademarks SMC is a registered trademark and EZ Switch is a trademark of SMC Networks Inc Other product and company names are trademarks or registered trademarks of their respective holders LIMITED WARRANTY Limited Warranty Limited Warranty Statement SMC Networks Inc SMC warrants its products to be free from defects in workmanship and mate
4. IMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES FOR CONSUMER PRODUCTS SO THE ABOVE LIMITATIONS AND EXCLUSIONS MAY NOT APPLY TO YOU THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS WHICH MAY VARY FROM STATE TO STATE NOTHING IN THIS WARRANTY SHALL BE TAKEN TO AFFECT YOUR STATUTORY RIGHTS SMC will provide warranty service for one year following discontinuance from the active SMC price list Under the limited lifetime warranty internal and external power supplies fans and cables are covered by a standard one year warranty from date of purchase SMC Networks Inc 6 Hughes Irvine CA 92618 COMPLIANCES FCC Class B This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide rea sonable protection against harmful interference in a residential installation This equip ment generates uses and can radiate radio frequency energy and if not installed and used in accordance with instructions may cause harmful interference to radio communi cations However there is no guarantee that the interference will not occur in a particu lar installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient the receiving antenna Increas
5. IR OR REPLACEMENT OF THE PRODUCT IN QUESTION AT SMC S OPTION THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES OR CONDITIONS EXPRESS OR IMPLIED EITHER LIMITED WARRANTY IN FACT OR BY OPERATION OF LAW STATUTORY OR OTHERWISE INCLUDING WARRANTIES OR CONDITIONS OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE SMC NEITHER ASSUMES NOR AUTHORIZES ANY OTHER PERSON TO ASSUME FOR IT ANY OTHER LIABILITY IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE OR USE OF ITS PRODUCTS SMC SHALL NOT BE LIABLE UNDER THIS WARRANTY IF ITS TESTING AND EXAMINATION DISCLOSE THE ALLEGED DEFECT IN THE PRODUCT DOES NOT EXIST OR WAS CAUSED BY CUSTOMER S OR ANY THIRD PERSON S MISUSE NEGLECT IMPROPER INSTALLATION OR TESTING UNAUTHORIZED ATTEMPTS TO REPAIR OR ANY OTHER CAUSE BEYOND THE RANGE OF THE INTENDED USE OR BY ACCIDENT FIRE LIGHTNING OR OTHER HAZARD LIMITATION OF LIABILITY IN NO EVENT WHETHER BASED IN CONTRACT OR TORT INCLUDING NEGLIGENCE SHALL SMC BE LIABLE FOR INCIDENTAL CONSEQUENTIAL INDIRECT SPECIAL OR PUNITIVE DAMAGES OF ANY KIND OR FOR LOSS OF REVENUE LOSS OF BUSINESS OR OTHER FINANCIAL LOSS ARISING OUT OF OR IN CONNECTION WITH THE SALE INSTALLATION MAINTENANCE USE PERFORMANCE FAILURE OR INTERRUPTION OF ITS PRODUCTS EVEN IF SMC OR ITS AUTHORIZED RESELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH DAMAGES SOME STATES DO NOT ALLOW THE EXCLUSION OF IMPLIED WARRANTIES OR THE L
6. e the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help EC Conformance Declaration Class B SMC contact for these products in Europe is SMC Networks Europe Edificio Conata II Calle Fructu s Gelabert 6 8 2 4 08970 Sant Joan Desp Barcelona Spain This information technology equipment complies with the requirements of the Low Voltage Directive 73 23 EEC and the EMC Directive 89 336 EEC and carries the CE Mark accordingly It conforms to the following specifications EMC EN55022 1988 CISPR 22 1995 Class B IEC 1000 4 2 4 KV CD 8 kV AD IEC 1000 4 3 1995 3 V m IEC 1000 4 4 1995 1 0 kV power line 0 5 kV signal line IEC 1000 4 6 1995 3 Vrms COMPLIANCES Industry Canada Class B This digital apparatus does not exceed the Class B limits for radio noise emissions from digital apparatus as set out in the interference causing equipment standard entitled Dig ital Apparatus ICES 003 of the Department of Communications Cet appareil num rique respecte les limites de bruits radio lectriques applicables aux appareils num riques de Classe B prescrites dans la norme sur le mat riel brouilleur Appareils Num riques NMB 003 dict e par le minist re des Communications Japan VCCI Class B COMBS FRUEFBFERBEB EHE VCCI OBR IEI
7. ellt werden Alle Hinweise und Warnungen die sich am Ger t befinden sind zu beachten Wird das Ger t ber einen l ngeren Zeitraum nicht benutzt sollten Sie es vom Stromnetz trennen Somit wird im Falle einer berspannung eine Besch digung ver mieden Durch die L ftungs ffnungen d rfen niemals Gegenst nde oder Fl ssigkeiten in das Ger t gelangen Dies k nnte einen Brand bzw elektrischen Schlag ausl sen Offnen sie niemals das Ger t Das Ger t darf aus Gr nden der elektrischen Sicher heit nur von authorisiertem Servicepersonal ge ffnet werden Wenn folgende Situationen auftreten ist das Ger t vom Stromnetz zu trennen und von einer qualifizierten Servicestelle zu berpr fen a Netzkabel oder Netzstecker sind besch digt b Fl ssigkeit ist in das Ger t eingedrungen c Das Ger t war Feuchtigkeit ausgesetzt d Wenn das Ger t nicht der Bedienungsanleitung entsprechend funktioniert oder Sie mit Hilfe dieser Anleitung keine Verbesserung erzielen e Das Ger t ist gefallen und oder das Geh use ist beschadigt f Wenn das Ger t deutliche Anzeichen eines Defektes aufweist Zum Netzanschlu dieses Ger tes ist eine gepr fte Leitung zu verwenden F r einen Nennstrom bis 6A und einem Ger tegewicht gr er 3kg ist eine Leitung nicht leich ter als HOSVV F 3G 0 75mm einzusetzen Der arbeitsplatzbezogene Schalldruckpegel nach DIN 45 635 Teil 1000 betragt 70dB A oder weniger iii COMPLIANCES iv
8. ents EZ Switch 10 100 SMC6405TX Appropriate DC power adapter 1 switch stand SMC Warranty Registration Card This User Guide Immediately inform your dealer in the event of any incorrect missing or damaged parts If possible please retain the carton and original packing materials in case there is a need to return the product Please fill out and return the Warranty Registration Card to SMC or register on SMC s Web site The EZ Switch 10 100 is covered by a limited lifetime warranty INSTALLING THE SWITCH Selecting a Site Be sure to follow the site selection guidelines below when choosing a location e Select a suitable location for the switch e It should be accessible for installing cabling and maintaining the switch e The temperature and humidity should be within the ranges listed in the specifications e The status LEDs should be clearly visible e There should be adequate space approximately two inches on all sides for proper air flow e Make sure twisted pair cable is always routed away from power lines fluorescent lighting fixtures and other sources of electrical interference such as radios transmitters etc e Make sure that a properly grounded power outlet is within 8 feet 2 44 meters of the switch and is powered from an independent circuit breaker As with any equipment using a filter or surge suppressor is recommended INSTALLING THE SWITCH Instructions 1 Positioning the Switch For wal
9. l mounting attach the switch stand to the wall with two small screws and then slide the switch s rear panel track onto the stand To stand the switch upright slide the base of the switch onto the stand To lay the switch flat slide the switch s rear panel track onto the stand 2 Applying Power Plug one end of the power adapter into the socket on the switch s side panel and the other end into an appropriate electrical outlet Check the Power LED to be sure power is on Note It is not necessary to power off the switch before connecting or disconnecting any UTP cables as these actions will not disrupt the operation of other devices attached to the switch 3 Connecting PCs Connect each PC to an RJ 45 port on the switch with a straight through twisted pair cable segment maximum length 100 meters 328 feet The EZ Switch 10 100 will support up to 5 PCs Note If an attached device does not support auto negotiation the data rate will be sensed automatically and the communication mode will default to half duplex 4 Cascading Switches and Other Network Devices All the ports on the switch support automatic MDI MDI X configuration for cable connections This allows you to use straight through cable to connect to other switches or hubs from any port on the switch No crossover cables or other device settings are needed See the Cable Specifications and Connectivity Guidelines sections of this guide for further informa
10. lways maintained even under heavy loading This switch is completely plug and play there is no configuration necessary Also the switch comes with its own versatile stand and can be mounted anywhere so it s ideal for small workgroups Features and Benefits e Auto negotiation of half or full duplex on all ports e Auto configuration for MDI MDI X cable connection allow connections to servers workstations hubs or switches to be made with straight through cabling IEEE 802 3u and 802 3 compliance ensures compatibility with standards based hubs switches and cards from any vendor e Store and forward switching ensures error free transmission e Half and full duplex flow control prevents packets from being dropped under heavy loading e Plug and play e Built in wiring crossovers on all ports At a glance LEDs for port and system status monitoring DESCRIPTION OF HARDWARE e Light weight compact construction with versatile switch stand for installation on a desktop or wall Front Panel LEDs The front panel of the switch provides status LEDs for at a glance gt system monitoring The following table details the functions of the various indicators Port and Switch Status LEDs LEDs Condition Status Power Green Switch is receiving power Link Activity Yellow Indicates a valid 10BASE T connection between the port and the attached device Flashing Indicates that the port is transmi
11. nd at http www smc com smc pages_html support html All products that are replaced become the property of SMC Replacement products may be either new or reconditioned Any replaced or repaired product carries either a 30 day limited warranty or the remainder of the initial warranty whichever is longer SMC is not responsible for any custom software or firmware configuration information or memory data of Customer contained in stored on or integrated with any products returned to SMC pursuant to any warranty Products returned to SMC should have any customer installed accessory or add on components such as expansion modules removed prior to returning the product for replacement SMC is not responsible for these items if they are returned with the product Customers must contact SMC for a Return Material Authorization number prior to returning any product to SMC Proof of purchase may be required Any product returned to SMC without a valid Return Material Authorization RMA number clearly marked on the outside of the package will be returned to customer at customer s expense For warranty claims within North America please call our toll free customer support number at 800 762 4968 Customers are responsible for all shipping charges from their facility to SMC SMC is responsible for return shipping charges from SMC to customer WARRANTIES EXCLUSIVE IF AN SMC PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY SHALL BE REPA
12. rials under normal use and service for the applicable warranty term All SMC products carry a standard 90 day limited warranty from the date of purchase from SMC or its Authorized Reseller SMC may at its own discretion repair or replace any product not operating as warranted with a similar or functionally equivalent product during the applicable warranty term SMC will endeavor to repair or replace any product returned under warranty within 30 days of receipt of the product The standard limited warranty can be upgraded to a Limited Lifetime warranty by registering new products within 30 days of purchase from SMC or its Authorized Reseller Registration can be accomplished via the enclosed product registration card or online via the SMC web site Failure to register will not affect the standard limited warranty The Limited Lifetime warranty covers a product during the Life of that Product which is defined as the period of time during which the product is an Active SMC product A product is considered to be Active while it is listed on the current SMC price list As new technologies emerge older technologies become obsolete and SMC will at its discretion replace an older product in its product line with one that incorporates these newer technologies At that point the obsolete product is discontinued and is no longer an Active SMC product A list of discontinued products with their respective dates of discontinuance can be fou
13. rom U S A and Canada 8 30 AM 8 00 PM Pacific Time 800 SMC 4 YOU 949 707 2400 949 707 2460 Fax From Europe 8 00 AM 5 30 PM UK Greenwich Mean Time 44 0 1188 748740 44 0 1189 748741 Fax INTERNET E mail addresses techsupport smc com european techsupport smc europe com Driver updates http www smc com support html World Wide Web http www smc com FTP Site ftp smc com FOR LITERATURE OR ADVERTISING RESPONSE CALL U S A and Canada Spain UK Southern Europe Central Eastern Europe Nordic Middle East South Africa PRC Taiwan Asia Pacific Korea Japan Australia India SMC Networks 6 Hughes Irvine CA 92618 Phone 949 707 2400 800 SMC 4 YOU 34 93 477 4920 44 0 1188 748700 33 1 41 18 68 68 49 0 89 92861 200 46 8 564 33145 971 48818410 27 0 11 3936491 86 10 6235 4958 886 2 2747 4780 65 238 6556 82 2 553 0860 81 45 224 2332 61 2 9416 0437 91 22 8204437 Fax 949 707 2460 Fax 34 93 477 3774 Fax 44 0 1189 748701 Fax 33 1 41 18 68 69 Fax 49 0 89 92861 230 Fax 46 8 87 62 62 Fax 971 48817993 Fax 27 0 11 3936491 Fax 86 10 6235 4962 Fax 886 2 2747 9220 Fax 65 238 6466 Fax 82 2 553 7202 Fax 81 45 224 2331 Fax 61 2 9416 0474 Fax 91 22 8204443 Model Number SMC6405TX Publication Number 150620 102 E022001 RO1
14. s For 10BASE T 100BASE TX connections a twisted pair cable must have two pairs of wires Each wire pair is identified by two different colors For example one wire might be red and the other red with white stripes Also an RJ 45 connector must be attached to both ends of the cable Caution Each wire pair must be attached to the RJ 45 connectors in a specific orientation CABLES The figure below illustrates how the pins on the RJ 45 connector are numbered Be sure to hold the connectors in the same orientation when attaching the wires to the pins 10BASE T 100BASE TX Pin Assignments With standard straight through 10BASE T 100BASE TX cable pins 1 and 2 are used for transmitting data and pins 3 and 6 for receiving data The and signs in the table below are used to represent the polarity of the wires that make up each wire pair Because all ports on this switch support automatic MDI MDI X operation you can use straight through cables for all network connections to PCs or servers or to other switches or hubs Straight Through RJ 45 Pin Assignments End 1 End 2 1 Txt 1 Tx 2 Tx 2 Tx 3 Rx 3 Rx 6 Rx 6 Rx 10 CABLES Connectivity Guidelines Maximum Fast Ethernet Network Diameter Repeater Type and Twisted Pair Twisted Pair Fiber Number 100BASE TX 100BASE TX and FX 1 Class I 200 m 656 ft 260 8 m 855 4 ft 1 Clas
15. s II 200 m 656 ft 308 8 m 1012 6 ft 2 Class II 205 m 672 4 ft 216 2 m 709 1 ft Note Network diameter is defined as the wire distance between two end stations in the same collision domain 11 SPECIFICATIONS SPECIFICATIONS EZ Switch 10 100 SMC6405TX 12 Ports 5 RJ 45 ports Ports 1 5 Twisted pair Auto MDIX configuration Network Interface RJ 45 100 ohm UTP cable 10BASE T Categories 3 4 or 5 100BASE TX Category 5 LEDs Power one Link Activity one per port Switching Method Store and forward MAC Address Table 4K entries Memory Buffer 1 Mbits per unit Filtering Forwarding Learning Rates Full line rate Size 5 1 x 3 7 x 1 4 in 13 0 x 9 5 x 3 5 cm Weight 0 48 lbs 0 22 kg SPECIFICATIONS Temperature Operating 32 to 122 F 0 to 50 C Storage 40 to 158 F 40 to 70 C Humidity noncondensing 5 to 95 Power Requirements DC input 9V 1A maximum Power Consumption 7 2 Watts maximum Heat Dissipation 24 8 BTU hr maximum Maximum Current 0 8A 9 VDC Standards IEEE 802 3 802 3u 802 3x 802 3ab for auto MDI MDI X configuration only EMC Safety Compliances CE Mark Emissions FCC Class B VCCI Class B EN55022 CISPR 22 Class B C Tick AS NZS 3548 1995 Class B Immunity IEC 1000 4 2 3 4 6 Safety CSA NRTL C22 2 950 UL 1950 TUV GS EN60950 Warranty Limited Lifetime 13 SPECIFICATIONS 14 FOR TECHNICAL SUPPORT CALL F
16. tion INSTALLING THE SWITCH Sample Application A typical application for the EZ Switch 10 100 is illustrated below EZ Switch 10 100 SMC6405TX Ethernet Hub or Switch Printer TROUBLESHOOTING TROUBLESHOOTING 1 Symptom Power LED does not light after power on Probable Causes Power outlet or power cord may be defective Possible Solutions e Check for loose connections e Check the power outlet by using it for another device e Replace the power cord 2 Symptom Link LED does not light after connection is made Probable Causes Switch port network card or cable may be defective Possible Solutions e Check that the switch and attached device are both powered on e Be sure the network cable is connected to both devices e Verify that Category 5 cable is used for 100 Mbps connections and that the length of any cable does not exceed 100 meters 328 feet e Check the network card and cable connections for defects e Replace the defective card or cable if necessary Cable Specifications CABLES CABLES Cable Types and Specifications Cable Type Max Length Connector 10BASE T Cat 3 4 5 100 ohm UTP 100 m 328 ft RJ 45 100BASE TX Cat 5 100 ohm UTP 100 m 328 ft RJ 45 Twisted Pair Cable and Pin Assignments Caution DO NOT plug a phone jack connector into any RJ 45 port Use only twisted pair cables with RJ 45 connectors that conform with FCC standard
17. tting or Yellow receiving data at 10 Mbps Green Indicates a valid 100BASE TX connection between the port and the attached device Flashing Indicates that the port is transmitting or Green receiving data at 100 Mbps DESCRIPTION OF HARDWARE SMC EZ Switch 10 100 SMC6405TX Power Link Activity 10Mbps Yellow 100Mbps Green Side Panel EZ Switch 10 100 SMC6405TX Front Panel Switch Stand Connectors Side Panel RJ 45 Ports The side panel ports are dual speed RJ 45 ports that support auto configuration for MDI or MDI X cable connection PCs switches or hubs can be connected to these ports with straight through cable Each port supports auto negotiation so the optimum communication mode half or full duplex and data rate 10 Mbps or 100 Mbps are selected automatically Rear and Bottom Panel Tracks The tracks on the rear and bottom panels are designed to slide into the switch stand for a variety of installation options The rear panel track is used for wall mounting or to lay the switch on a flat surface The bottom panel track is used to stand the switch upright INSTALLING THE SWITCH INSTALLING THE SWITCH With its versatile switch stand the EZ Switch 10 100 SMC6405TX can be securely mounted on a desktop or shelf in either an upright or flat position or on a wall Equipment Checklist After unpacking the EZ Switch 10 100 check the contents of the box to be sure you ve received the following compon