Home
Slant/Fin GF-200B User's Manual
Contents
1. sufficient time to dry before plugging the electrical cord into the outlet 10 Plug in the unit and resume normal use CHANGING THE UV GERMICIDAL BULB 1 If the REPLACE UV BULB indicator illuminates during normal use it is time to change the UV germicidal bulb which is a special 3 5W bulb 2 Turn the ON OFF switch to the OFF position unplug it and allow it to cool 3 Remove the water tank from the base of the humidifier 4 Place the base of the humidifier over the sink and tilt the unit to remove any remaining water 5 Carefully turn the base of the humidifier over and place it upside down on a flat level surface You will see a door that is closed with a screw 6 Using a Phillips head screwdriver carefully turn the screw counterclockwise until the screw separates from the door 7 Open the door The UV germicidal light bulb will be visible 8 Take a replacement 3 5W UV germicidal bulb that you purchased from Slant Fin Corporation or another supplier and change the bulb To prolong the life of the bulb limit your direct contact with the glass of the bulb by using a cloth or tissue to screw it into place 9 When the new bulb is in place close the door and replace the screw by using your Phillips head screwdriver and rotating it clockwise until it is just tight DO NOT OVER TIGHTEN 10 Turn the unit upright place the water tank on top of the base of the humidifi er plug the unit in and turn the
2. In English 1 10 En Frangaise 11 20 Slant Fin En Espa ol 2130 Portable Electric Warm Mist Humidifier with fan Germ Free Model GF 200 GF 200B GF 210 and GF 210W GF 200 Shown Patented e Instructions for Operation Care and Cleaning e Limited Warranty READ AND SAVE THESE INSTRUCTIONS Printed in CHINA 8 00 Publication GF 200 200B 210 210W 40EFS Imprim aux CHINE 8 00 C Impreso en CHINA 8 00 pari Number 31 1001 READ ALL OF THE FOLLOWING INSTRUCTIONS BEFORE ATTEMPTING TO OPERATE YOUR HUMIDIFIER FOLLOWING THESE SIMPLE GUIDELINES FOR USE AND CARE WILL HELP ENSURE YEARS OF DEPENDABLE AND EFFICIENT SERVICE IMPORTANT SAFEGUARDS CAUTION BECAUSE HIGH TEMPERATURE IS GENERATED IN THIS HUMIDIFIER BASIC SAFETY PRECAUTIONS SHOULD ALWAYS BE FOLLOWED ESPECIALLY WHEN CHILDREN ARE PRESENT WHEN USING ELECTRICAL APPLIANCES THESE BASIC SAFETY PRECAUTIONS MUST BE FOLLOWED DO NOT operate the humidifier without the water tank ALWAYS use clean cool tap water to fill the water tank To avoid risk of fire or shock DO NOT use an extension cord DO NOT handle the unit with wet hands NEVER tilt move or attempt to empty the unit while it is operat ing or plugged in Shut off unplug and remove water tank before moving unit DO NOT place the unit close to heated areas such as near stoves heaters or in direct sunlight DO NOT operate OUTDOORS This humidifier is intended for indoor use only DO NOT let wat
3. ON OFF switch to the ON position The REPLACE UV BULB indicator should no longer be lit IMPORTANT NOTE Even though you will not receive maximum germicidal effects you can still use your GF 200 and GF 210 humidifier until the replace ment bulb arrives STORAGE TIPS If you do not plan to use your humidifier for an extended period of time such as during the summer months it is important that you follow these instructions to help prevent problems from developing in the unit 1 Clean your humidifier as instructed in the section titled Cleaning and Maintenance 2 Make sure all water is emptied from the tank and the hot and cold water reservoirs 3 Dry your unit thoroughly 4 Leave the tank cap off to expose the tank to air 5 Pack your humidifier in its original carton and store it in a cool dry place SERVICE DO NOT attempt to repair this humidifier yourself For repairs covered under the warranty contact Slant Fin by telephone or mail for a Return Authorization Number Have other repairs professionally performed GLOW It is normal to see the humidifier glow when operating in a darkened room This glow results from the internal illumination of the 3 5 watt UV bulb However no ultraviolet light even at this harmless level passes through the UV proof cabinet into the room TROUBLESHOOTING TROUBLE POSSIBLE CAUSES SOLUTION Unit does not mist Unit is not plugged in Plug in unit Power failure Check c
4. ed in duration to the time periods after the date of original purchase as stated above The warranty does not cover claims for incidental or consequential damages resulting from a breach of any express or implied warranty or any other reason including damages due to accident abuse lack of responsible care the affixing of any unauthorized attachment loss of parts or use at a voltage other than specified CUSTOMER SERVICE 1 800 775 4552 Slant Fin Humidificateur lectrique portatif atomisation de bruines ti des avec ventilateur Germ Free Mod le GF 200 GF 200B GF 210 et GF 210W GF 200 Brevet e Instructions sur le fonctionnement l entretien et le nettoyage e Garantie limit e LIRE ET CONSERVER CES INSTRUCTIONS
5. er get into the air inlets on the bottom of the enclosure or on the cord or plug DO NOT store or use gasoline or other flammable vapors and liq uids near the humidifier ALWAYS make sure the water tank cap and gasket are firmly in place DO NOT touch hot surfaces ALWAYS turn the humidifier off when the water tank is empty or when the unit is not in use If you turn your unit off for extended periods ALWAYS disconnect the power cord and empty the water tank and base ALWAYS place the unit on a firm flat level water resistant surface and arrange the power cord so that the product is unlikely to be upset DO NOT clean the product or service the UV germicidal bulb with out disconnecting the power cord Before connecting to electric power outlet check your electrical power supply It must be 120 volts A C alternating current The outlet may be 15 amp or 20 amp The circuit must be of adequate size and must be protected by fuse or circuit breaker This item has a polarized plug As a safety feature this plug will fit in a polarized electrical receptacle outlet only one way If the plug does not fit fully in the outlet reverse the plug If it still does not fit contact a qualified electrician DO NOT attempt to remove MIST NOZZLE during operation or within 15 minutes after the humidifier is turned to the OFF RESET position and unplugged Serious injury may result DO NOT place hands or face directly o
6. he air The first step uses a UV germicidal bulb located inside the base of the humidifi er that shines on the water through a special glass tube as it passes from the cold water reservoir to the hot water reser voir The second step is the boiling action that takes place in the hot water reservoir just before the mist is distributed Rr fan to the air in the room These two methods limit the likelihood of harmful microorganisms getting into the atmosphere and being breathed by you your family and pets CONTROL PANEL ON OFF SWITCH When the switch is turned to the ON setting and the unit is plugged in the power is on GF 200 REPLACE UV BULB If the REPLACE UV BULB signal light is illuminated during normal use the REFILL RESET INDICATOR When illuminated the water tank needs refill ing See the section Filling the Water Tank If still illuminated after full tank is placed on base see TROUBLESHOOTING section Page 9 RELATIVE HUMIDITY CONTROL This controls the humidity level If mod erate humidity is desired the control should be turned counterclockwise toward LO and if higher humidity is desired clockwise toward HI NOTE When you unpack your humidifier you may find it has droplets of water on some surfaces This is normal as every unit is tested prior to shipping Carefully unpack humidifier and remove all packing material OPERATING INSTRUCTIONS 1 Fill the Water Tank accord
7. ing to the instructions below and place on humidifier base 2 Plug the power cord firmly and completely into the wall outlet 3 Turn the switch to the ON position It will be normal for the humidifier to take 2 minutes to warm up and begin to mist 4 When the water tank is empty after approximately 24 hours running time the REFILL RESET WHEN LIT lamp will go on and the unit will stop heat ing Refer to the FILLING THE WATER TANK section 5 Whenever the water falls below the level of the probes during operation the heating element will shut off and stop heating 6 Mist nozzle may be adjusted manually by pointing in desired direction GF 200 only NEVER point at wall 7 Mount humidifier on drip tray if using unit on wood surface or other surface that could possibly be damaged by accidental water spillage or condensation FILLING THE WATER TANK 1 Before filling the water tank turn the ON OFF switch to the OFF position and unplug unit 2 Remove water tank from base turn the tank upside down and remove tank cap by turning counterclockwise Fill tank with clean cold tap water Replace the tank cap by turning clockwise Tighten firmly 3 Carefully pick up tank since it will be heavy when full and slippery if wet 4 Place water tank on base Make sure tank is properly placed otherwise the humidifier will not work correctly USING THE MEDICATION CUP MIST OUTLET GRILLE In order to add a medicated vap
8. ircuit breaker Water tank empty Remove and refill Power switch not turned on Turn on switch Unit not reset after refilling tank Check that there is water in the hot water reservoir Water tank not properly Reposition water tank located on base unit Humidity level set is achieved Turn Relative Humidity Control to higher setting Water leaks from unit Drain cap drain cap gasket Tighten cap Replace tank cap or tank cap gasket or reposition cap is missing or improperly gasket positioned Moist air output low Mineral buildup in hot water Clean unit as per reservoir instructions LIMITED WARRANTY IMPORTANT NOTICE PLEASE CLEAN THIS GERM FREE HUMIDIFIER AT LEAST ONCE A WEEK BY FOLLOWING THE CLEANING INSTRUCTIONS IN THE OWNER S MANUAL FAILURE TO REGULARLY CLEAN THIS GERM FREE HUMIDIFIER WILL RESULT IN A BUILDUP OF MINERAL DEPOSITS WHICH WILL CAUSE THE UNIT TO CEASE TO OPERATE IF THE UNIT FAILS TO FUNCTION BECAUSE IT HAS NOT BEEN CLEANED THIS WILL VOID THE WARRANTY To the original purchaser or gift recipient of this humidifier 1 If your Slant Fin humidifier fails in normal use because of a manufacturing defect within 90 days from the date of original purchase Slant Fin will repair the humidifier at no charge for parts labor or shipment back to you see instructions for returning unit below 2 After the first 90 days if a component part fails because of a manufacturing defect Slant Fin will repair or replace that comp
9. onent part up to 3 years from purchase date There will be no charge for the component part or shipment back to you but Slant Fin reserves the right to charge for installa tion labor 3 This warranty does not cover any product which in Slant Fin s judgment has been 1 damaged as a result of accident misuse or abuse 2 used for a purpose for which it was not designed or 3 repaired or altered in any way that adversely affected its performance or reliability This warran ty does not cover scratches and wear of surfaces 4 UV bulb replacement is a normal maintenance procedure and is therefore not covered under this warranty unless the bulb is found to be defective 5 For repairs return humidifier to address shown below with dated sales receipt The cost of shipment to Slant Fin must be paid by the consumer Return to Consumer Service Dept Slant Fin Corporation 40 Garvies Point Road Glen Cove NY 11542 In Canada Slant Fin LTD LTEE 6450 Northam Drive Mississauga Ontario L4V 1H9 6 This warranty gives you specific legal rights and you may also have other rights which vary from state to state 7 Slant Fin makes no express warranties other than the warranties con tained herein Slant Fin s sole obligation in the event of a breach of any implied warranty including but not limited to implied warranties of mer chantability and fitness for a particular purpose is limited to repair or replacement and all such warranties are limit
10. or to the mist output 1 Turn the ON OFF switch to the OFF position and allow the outlet grille bulb must be replaced with the same special 3 5W bulb See the enclosed order to cool form The UV germicidal bulb will operate at maximum output for approximately Lift the medication cup 2 000 hours typically 1 to 2 years of normal operation The UV germicidal bulb Carefully add liquid medication DO NOT fill the cup more than half full may operate longer than 2 000 hours but at a reduced output To keep your Carefully replace the medication cup humidifier operating at maximum efficiency it is recommended that the UV ger Turn the ON OFF switch to the ON position micidal bulb be replaced after 2 000 hours of use After use remove the cup from the unit and clean any residue from the cup with warm water oor WP WARNING DO NOT use any liquid medication other than those specifically recommended for use with a steam vaporizer or warm mist humidifier DO NOT pour medication directly into the mist outlet grille openings nor add it to the water in the tank or tray MINERAL ABSORPTION PAD INSTRUCTIONS Warm mist humidifiers do not spread fine mineral dust into the air that you breathe nor on your furniture the way that other type humidifiers do The miner al dust remains trapped in the humidifier hot water reservoir Use of Mineral Absorption Pads will play a major role in capturing and removing minerals from hot
11. orm the necessary cleaning steps will damage unit 1 Before cleaning set CONTROLS to OFF position and unplug unit 2 Remove water tank from humidifier base and drain water from tank 3 Allow at least 15 minutes after shutting unit OFF before moving base or removing mineral absorption pad Remove mineral absorption pad from hot water reservoir using tweezers or tongs to prevent burns from hot water When the cleaning procedure is completed replace mineral absorption pad To drain water from humidifier base grasp with both hands and tilt to the side draining water into the sink BE CAREFUL NOT TO HAVE DRAINING WATER FALL INTO CONTROLS OR VENT OPENINGS DO NOT drain in any manner other than indicated WARNING DO NOT place directly under running faucet Turn the base upside down and remove the cap by turning it counterclockwise Clean out any foreign matter that has accumulated inside the fitting from which the cap was removed After cleaning replace this cap tightly by hand Pour a small amount of water into the hot water reservoir and check for leaks from this cap under the base 4 Pour about 1 cup of white vinegar into either reservoir and allow it to soak for only 20 to 30 minutes 5 Hold the base of the humidifier over the sink and tilt it on its side to empty the vinegar Fill the cold and hot water reservoirs with clean warm water to remove all traces of the vinegar Remove any buildup of minerals in the hot wate
12. r reservoir and from the two metal water level probes they appear like two metal wires using a small brush such as a toothbrush NOTE The buildup is due to water hardness The harder your water the more often this maintenance will be needed Empty all of this water by turning the unit on its side DO NOT ALLOW WATER TO ENTER THE BOTTOM OF THE HUMIDIFIER BASE OR ANY OTHER OPENINGS OR IMMERSE THE CORD AND PLUG 6 Disinfect the water tank using a solution of one teaspoon of household chlo rine bleach in 1 gallon of water Let the solution sit for 20 minutes swishing every few minutes to wet all surfaces Empty the tank completely rinse thoroughly until all of the bleach smell is gone Fill the tank with fresh cool water and replace it onto the humidifier base 7 NEVER use any metal or hard objects to clean plastic parts which may cause scratching of the plastic parts The only exception to this is the metal part of the hot water reservoir A metal scraper can be used to clean this part only NEVER use gasoline kerosene glass cleaner furniture polish paint thinner or other household solvents to clean any part of the humidifier 8 Each day the reservoir and tank should be drained rinsed and refilled with fresh tap water 9 To clean exterior surfaces use a solution of water and mild detergent with a wrung out damp cloth Rinse and wring out the cloth and wipe the exterior surfaces again Finally wipe with a dry cloth Allow
13. ver MIST NOZZLE while unit is in operation Place unit in an area where it is not accessible to children Before using the unit check the power cord for any signs of damage DO NOT allow the MIST NOZZLE to face directly at a wall sur face Direct mist aimed at wall could cause damage particularly to wallpaper This humidifier requires daily and weekly maintenance Refer to CLEANING AND MAINTENANCE instructions provided NEVER clean humidifier in any other manner than as instructed by this manual SAVE THESE INSTRUCTIONS MEDICATION CUP MIST OUTLET GRILLE TANK HANDLE MIST NOZZLE _MATER TANK _ MINERAL ABSORPTION PAD TANK CAP c HOT WATER RESERVOIR BASE AND GASKET gt _HUMIDISTAT ON OFF SWITCH BASE CAP N REFILL RESET INDICATOR AND GASKET REPLACE UV BULB NDICATOR WEEKLY CLEANING AND MAINTENANCE ADVISORY At least weekly cleaning is recommended when the unit has been in use Regular cleaning prevents mineral scale buildup in the hot water reservoir It also helps prevent buildup of bacteria molds or other micro organisms in the tank or system This ensures that your humidifier will operate at maximum efficiency See page 6 for full cleaning instructions GF 200 HOW YOUR SLANT FIN WARM MIST HUMIDIFIER WORKS This model humidifier uses a two step approach to eliminate potentially harmful microorgan isms from the water before they are spread with the mist into t
14. water reservoir and preventing a stubborn mineral buildup 1 Before starting humidifier place mineral absorption pad in the hot water reservoir After the humidifier has been operating the water will become HOT and CAUTION should be exercised when handling mineral absorption pad It is best to allow humidifier water to cool down and to use tongs or long tweezers when handling pad 2 The useful life of the mineral absorption pad will vary depending on the min eral content of the water used In areas of moderate mineral content water supply the mineral absorption pad should be changed after approximately 3 weeks of continuous use If the water is Hard Water the pad should be changed more frequently The best way to tell when the pad should be changed is to examine it AFTER the water has cooled down to see if it is still soft and pliable When the pad is near the end of its life it becomes stiff and hard and should be replaced with a new pad Another sign to change pad is when scale begins to buildup on interior of hot water reservoir CLEANING AND MAINTENANCE Water contains minerals and other particles During operation most of these minerals will remain in the water reservoir Gradual buildup of deposits will coat the hot water reservoir and reduce its efficiency The importance of routine cleaning and care can not be over emphasized Hard water contains more minerals and other particles CLEANING INSTRUCTIONS Failure to perf
Download Pdf Manuals
Related Search
Related Contents
Para obtener mas informaciones acerca de mquinas Foredom WARTUNGSHANDBUCH - Edenhofner Forstgeräte II Project - Department of Higher Education Generated Java Method Format and Calling Parameters Plaquette Onduleurs Rack/Tour Desk Monde Radio-Télévision Especificaciones Digital Broadcaster Version 3.4 User Manual – Utilities Copyright © All rights reserved.
Failed to retrieve file