Home
SkyLink HA-434TL User's Manual
Contents
1. connector position 1 or Low connector position 2 position When the sensitivity is set to Low more movement is required to trigger the sensor It is recom mended to set the sensitivity to Low and perform a Walk Test If the walk test result is satisfied the sensitivity does not require to be adjusted further If the walk test result shows the sensitivity is too low then you can change the sensitivity setting to High Please perform the walk test after changing the sensitivity setting 1 High 2 Low 4 OPERATION There are 3 different operating modes for the Household Alert Long Range Receiver 1 Alert Beeps when a sensor is activated corresponding zone LED will also flash 2 Alarm Sounds an alarm when a sensor is activated corresponding zone LED will also flash 3 Off No audio sound will be emitted when sensor is activated Zone LED will flash to indicate the activated sensor To select the operating mode place the slide switch on the side at the desired setting OFF No Audio ALERT Alert Mode ALARM Alarm Mode Operation Alert When motion is detected in the monitored area the sensor will send a signal to the receiver It will beep and the corresponding zone red LED will flash for 15 seconds If the sensor is set to zone 1 zone 1 red LED on the receiver will flash and the receiver will emit a continuous sing
2. Indoor Outdoor Motion Sensor Model HA 434TL 1 INTRODUCTION The Indoor Outdoor Motion Sensor is designed to monitor movement around your house The motion sensor can be placed either indoor or outdoor Once motion is detected the receiver will respond with flashing along with alert beeping or alarm In this package you should find an Indoor Outdoor Motion Sensor ball head joint screws Ball head joint 2 pcs 3x 18 screws Included Indoor Outdoor Motion Sensor Please follow the instructions below to setup your motion sensor 2 PROGRAMMING The sensor must be programmed to the Household Alert Long Range Receiver before they can communication You may program the sensor to one of the 4 zones Follow the instructions below 1 Plug in an AC adapter to the receiver 2 The green LED will be on indicating it is turned on 3 Open the back cover and there is a learn button Press and hold this learn button for 5 seconds until both green LED and zone 1 red LED flash You may now release the learn button 4 If you would like to program the sensor to zone 1 activate the sensor while the zone 1 red LED is flashing Press the SET button on the back of the sensor to activate it 5 If you would like to program the sensor to other zones press the learn button again until the red LED flashes at the zone you want to program the sensor to then activate the sensor 6 Once the sensor is programmed the green LED will be stead
3. cts or have difficulty getting them to work or download information and user manual please 1 visit our FAQ section at www skylinkhome com or 2 email us at support skylinkhome com or 3 call our toll free at 1 800 304 1187 from Monday to Friday 9 am to 5 pm EST Fax 800 286 1320 CUSTOMER SERVICE 17 Sheard Avenue Brampton Ontario Canada L6Y 1J3 Email support skylinkhome com http www skylinkhome com P N 1012754 2010 SKYLINK GROUP
4. ily on and none of the red zone LEDs will be on SET Button P Insert 9V alkaline battery option to the sensor Learn Button Note Each zone can program up to 4 sensors If you try to program a fifth sensor into a zone the first programmed sensor will be erased Erasing a sensor You cannot erase a specific sensor You must erase all sensors from the receiver then program the ones you would like to keep To erase all the sensors from the receiver 1 Remove the adapter from the receiver 2 Open the back cover press and hold the learn button Do not release the learn button until step 4 3 While holding onto the learn button plug in the adapter to the receiver 4 You may release the learn button when the LEDs on the receiver are on 5 You have erased all sensors from the receiver 3 INSTALLATION MOUNTING A ball head joint is necessary to mount the sensor at a desire location A height of 7 ft is recommended depending on your application Once a location is selected mount the ball head joint to this location by screws provided Once the ball head joint is mounted to the wall slide the back of the sensor into the ball head joint The mounting angle can be adjusted Please refer to Walk Test to determine the best mounting angle WALK TEST After mounting the sensor at the desired location it is important to perform a walk test in order to determine if the sensor is detect
5. ing the things you want to detect In order to control how far the sensor can see this can be done by adjusting the angle of the sensor To reduce the detection range simply move the sensor downward To increase the range move the sensor up to around 12 degrees This will give the maximum range However this may not be desired if the sensor is placed outdoors since a false trigger may occur if the sensor is set to detect motion in a distance You should walk in the area that you would like the sensor to monitor Place the slide switch on the side of the receiver to Alert position The receiver will beep if the sensor detects your movement If the receiver does not respond adjust the mounting angle accordingly After motion is detected once the sensor will not be triggered unless no motion is detected for 20 seconds Therefore wait for at least 20 seconds during walk testing between 2 activations Perform walk test in the undesired area to ensure movement cannot be detected Tips The sensor should not face towards direct sunlight placing near heat or cold producing devices i e A C or furnance vents fans ovens heaters etc that may cause false triggers 12 Move the sensor downward to reduce the range Move the sensor up to around 12 to give maximum range SENSOR SENSITIVITY The sensitivity of the motion sensor is adjustable Change the setting by placing the connector on either the High
6. le beep i e beep pause beep pause etc if the sensor is set to zone 4 zone 4 red LED will flash and the receiver will emit a continuous 4 beeps i e beep beep beep beep pause beep beep beep beep pause etc By the number of beeps emitted by the receiver user can identify which zone is triggered Mute When a sensor is triggered for a long period of time you may stop the buzzer by pressing the mute button When another signal comes again you can disable the buzzer for all currently activated sensors by pressing the mute button The receive will beep again if it receives another signal For instance if you are working in your garage you may want to disable the buzzer for this garage only Then you can press the Mute button after it starts to sound If any other sensor is triggered the receiver will sound again Alarm When the receiver is in Alarm operation mode it will sound its siren when a sensor is activated The maximum alarm duration is set for 3 minutes To terminate the siren during the 3 min interval press the mute button Although the alarm siren is terminated if that sensor is still activated its corresponding LED will continue to flash Note This audio siren is not intended to prevent intruder break in it is rather an alert signal indicating a sensor is activated Therefore turning off the siren does not require specific password Off No audio
7. uld void the user s authority to operate the equipment NOTE This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful inter ference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment dose cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help 8 WARRANTY If within one year from date of purchase this product should become defective except battery due to faulty workmanship or materials it will be repaired or replaced without charge Proof of purchase and a Return Authorization are required 9 CUSTOMER SERVICE If you would like to order Skylink s produ
8. will be emitted even sensor is activated Only zone LED will flash 5 LOSS OF SIGNAL INDICATION When the battery level on the sensor drops to a certain level or the sensor is out of the operating range the receiver will show a loss of signal indication The red LED representing that zone will flash rapidly i e if zone 1 sensor is lost the zone 1 red LED will flash rapidly When the loss of signal indication occurs move the receiver closer to the corresponding sensor and trigger that sensor If the red LED stops flash ing rapidly that means the receiver or sensor needs to be relocated If the loss of signal indication persists replace the battery of that sensor 6 OTHER HOUSEHOLD ALERT SENSORS The Household Alert Long Range Receiver can work with up to 4 different sensors garage door monitor sensor door window sensor water sensor indoor outdoor motion sensor etc Please visit www skylinkhome com or contact us at support skylinkhome com for more information of how to fully utilize your Indoor Outdoor Motion Sensor 7 FGC This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation WARNING Changes or modifications to this unit not expressly approved by the party responsible for compliance co
Download Pdf Manuals