1. INSTALLATION INSTRUCTIONS CARE AND USE MANUAL FOR POWER PACK RANGE HOODS Models covered by these instructions SU900 SUT900 SCH31A BEFORE INSTALLATION ENSURE THERE IS NO VISIBLE OR HIDDEN DAMAGE SUSTAINED DURING SHIPPING SHIPPING DAMAGE MUST BE REPORTED WITHIN 5 DAYS OF RECEIPT e e Sirius Range Hoods Telephone Toll Free 866 528 4987 Fax Toll Free 866 365 9204 www siriushoods com info siriushoods com N WARNINGS Thank you for purchasing a Sirius Range Hood Please read all the instructions in this manual before installing the appliance Save these instructions for future reference The appliance is not intended for use by young children or infirm persons without supervision Young children should be supervised to ensure they do not play with the appliance If the range hood is vented the air so vented must be ducted into a dedicated duct that is not showed with any other eguipment whatsoever All ducting must conform to all reguirements of the local authority If the range hood is to be used inside he same structure home or building as any eguipment hat burns combustible material such as oil coal gas etc then pervision must be made for make up air Under certain circumstances the range hood could create a negative air pressure inside the structure This negative air pressure must not exceed 0 04 mbar please consult your local HVAC professional for guidance at this point The use
2. Each 3 1 4 x 10 to 6 Transition used Side Wall with damper Roof Cap hood is 100 Calculate your duct run by measuring linear feet and adding the elbows transitions and caps based on the table alongside The ducting connection to the hood must be in line with the central vertical axis of the range hood 1 away from the back wall on which the hood is to be mounted Range hoods may interrupt the proper flow of combustion gases from fireplaces gas furnaces and gas water heaters To minimize the risk of drawing these lethal gases back into the home please follow the heating equipment manufacturers safety standards and guidelines carefully Refer to NFPA and ASHRAE for additional information ELECTRICAL WARNING All electrical work must be performed by a qualified electrician Please ensure that the appropriate electrical codes or prevailing local building codes and ordinances are adhered to Ensure that the electricity supply is disconnected at source Do not use an extension cord or adapter plug with this appliance This appliance must be grounded Connect to a properly grounded branch circuit protected by a 15 amp circuit breaker Electrical Supply This range hood reguires a 120V 60Hz supply and draws a maximum of 3 amps The electrical supply to the range hood should be at least 17 from the underside of the installed range hood For a typical installation where the underside of t
3. of combustible material in close proximity of the range hood must be avoided When frying please pay particular attention to fire risk due to grease Being highly inflammable fried oil is especially dangerous In order to avoid possible fire risk all instructions for grease filter cleaning and for removing eventual grease deposits must be followed strictly If the rating label in the cooker hood shows the If the rating label in the cooker hood does not symbol the appliance is built in class II and show the symbol the appliance is built in it does not need any ground connection class 1 and it needs the ground connection Only use this appliance as an exhaust ventilation system for the removal of cooking vapors DO NOT use to expel flammable substances or any other materials or vapors The installation procedures in this manual are intended for qualified installers service techni cians or persons with similar qualified background DO NOT attempt to install this appliance yourself When performing the electrical connections on the appliance please ensure that the current supply is provide with ground connection and that the voltage values correspond to those indicated on the label placed inside the appliance itself Ensure that electrical power is turned off at source before commencing installation All electri cal wiring must be properly installed insulated and grounded and conform to all applicable codes and standards Ma
4. sure it lines up with the cut out in your cabinet refer to figure 5 The SUT900 has pressure springs on the front and back that will hook onto the top surface of the underside of the hood when it is pushed up into the hole that has been cut out refer to figure 6 Figure 6 There are four holes on the inside of the SUT900 to fix the unit into the edge of the base of the wooden hood refer to figure 7 CL yy Figure 7 Connecting Electricity and Ducting Please refer to the Electrical Supply section on page 2 for the required location of the electrical supply CAUTION Make sure the power is turned off at source Make electrical connections refer to Figure 8 Ensure that the plastic flaps at the exhaust outlet for the fan move freely and have not become jammed or stuck N Cable lock maybe required by local law NOT SUPPLIED Figure 8 Connect the appropriate length of ducting to the fan exhaust point and join up with the ducting to the exterior Do not fix the ducting to the range hood exhaust outlet with screws use duct tape Use duct tape on all joints Re Circulating Requirements If the unit is to be used in the re circulating mode fit the carbon filters after the installation is complete refer to Figure 9 Figure 9 The carbon filter fits in behind the aluminium grease filter Ensure that the plastic tabs on the carbon filter are facing outwa
5. ERED Sirius Range Hoods warrants to the original consumer purchaser of its products that such products will be free from defects in materials and workmanship for a period of three years from the original date of purchase There are no other warranties express or implied including but not limited to implied warranties of merchantability or fitness for a particular purpose or application WHAT IS NOT COVERED This warranty does not extend to filters lamps batteries ducts and ductwork components This warranty does not cover normal maintenance and service or products or parts which have been subject to misuse negligence accident improper maintenance or repair faulty installation or installation contrary to recommended installation instructions The warranty on glass screens is limited to manufacturing defects only and expressly excludes cracks and breakages as a result of faulty installation Labor and associated costs associated directly with removal and re installation are expressly excluded The duration of any implied warranty is limited to the three year period as specified for the express warranty Some states and provinces do not allow limitation on how long an implied warranty lasts so the above limitation may not apply to you Canada Sirius Range Hoods Ltd USA Sirius Range Hoods Ltd 1252 Speers Road Unit 11 1051 Clinton Street Oakville ON L6L 5N9 Buffalo NY 14206 Register Online www siriushoods com warranty htm S
6. be replaced immediately Do not operate blower when filters have been removed Allow filters to dry before replacing them otherwise water will be drawn into the blower If a carbon filter has been fitted this must be replaced every 6 months as a minimum depending on usage and type of cooking that is performed It is suggested that a spare set of carbon filters is kept on hand These can be ordered from the supplier of your range hood Cleaning the Hood The outside and interior of your hood should be wiped regularly with a clean damp cloth and mild household dish detergent or degreaser Use a good quality non abrasive foaming type stainless steel cleaner for exterior surfaces Follow the manufacturers directions Generally the foam is sprayed onto a clean dry cloth and then applied to the stainless steel Allow the foam to react on the surface for a few minutes and then wipe with a clean dry cloth On the surfaces that are exposed directly to heat from the cook top it is advisable to clean these regularly to avoid the deposits from becoming baked on Do not use abrasive cleaning agents as these will destroy the brushed finish Light Bulb Replacement If in doubt call 866 528 4987 Turn blower and lights off Make sure the lights are cool If new lights do not operate check fuses and be sure globes and breakers are in serted correctly Remove the glass blocking ring by prying out with a sharp soft
7. he range hood will be 30 above the counter top and the counter top is 36 above the floor level the electrical supply should be 76 above floor level and no further than 3 to the right as you face the wall of the central axis of the range hood INSTALLATION Applications The SUT900 can either be installed inside a wall cabinet provided the inside depth is greater than 11 or used in a custom designed wooden hood Where installed directly into a wall cabinet there are two options Directly into the cabinet without any form of hood Directly into the cabinet together with Sch31A where the Sch31A acts as a liner hood and is attached to either the underside of the cabinet or into the sides of the cabinets alongside Depending on which model is used prepare a cut out in the underside of the wooden hood to allow the SUT900 to fit up into the hood refer to figure 3 or 4 If Sch31A is being used it can be held up under the cabinet and used as a template Remember to make the depth 10 3 Figure 3 For the 20 5 model the cut out should 19 4 x 10 3 Figure 4 For the 27 6 model the cut out should be 26 5 x 10 3 3 Please ensure that the SUT900 is installed as far forward in the wooden hood as possible and centered over the cooking area If Sch31A is to be used for under cabinet application it should be installed now Screw Sch 31A to the 4 hole locations Make
8. instrument such as a toothpick refer to Figure 10 Steel instruments will scratch the surface Be careful that the glass does not fall out and break Do not remove the entire fixture socket as this is very difficult to reinstall Replace the appropriate bulb Check parts brochure or speci fication sheets on our website Wipe both sides of the glass whilst it is out Re insert the glass blocking ring and fasten it Figure 10 Three Year Limited Warranty WARRANTY SERVICE To qualify for warranty service you must notify Sirius Range Hoods at the address stated below or call toll free USA or Canada 1 866 528 4987 and provide the model number description of the fault or defect and original date of purchase Sirius reserves the right to request proof of original purchase Sirius will at its sole option and discretion replace products that arrive damaged through shipping provided shipping damage is reported as stated above within 5 business days of receipt of the shipped product or products ONE YEAR SERVICE REPAIR WARRANTY During the first year from date of original purchase Sirius will at its option repair or replace without charge any product or part which is found to be defective under normal use and service THREE YEAR PARTS WARRANTY For three years from date of purchase Sirius will provide free of charge non consumable replacement parts which are found to be defective under normal use and service WHO IS COV
9. ke sure all existing ductwork is clean of grease build up or ductwork should be replaced if necessary to avoid the possibility of a grease fire Check all joints on ductwork to ensure proper connection and all joints should be properly taped Be careful when cutting through ceilings or walls not to damage any hidden pipes or electrical wiring Ensure your kitchen has sufficient air return vents to replace the exhausted air TABLE OF CONTENTS BEFORE YOU BEGIN DUCTING External Venting Requirements Duct Run Calculation ELECTRICAL Electrical Supply INSTALLATION Applications Connecting Electricity and Ducting Re Circulating Requirements OPERATING PROCEDURES General Advice Functions MAINTENANCE Cleaning the Filter Cleaning the Hood Light Bulb Replacement WARRANTY BEFORE YOU BEGIN The manufacturer declines all responsibility in the event of failure BEFORE YOU BEGIN to observe the instructions given It is advisable to test run the here for installation maintenance range hood before installation and suitable operation of the product The manufacturer further Please read this entire manual and declines all responsibility for injury ensure that you are fully conversant due to negligence and the warranty with the requirements and limitations of the unit automatically expires due to improper maintenance and or installation DUCTING permitted by code Flexible ducting could restrict airfl
10. metal tray If the flames do not go out immediately EVACUATE AND CALL THE FIRE DEPARTMENT Never pick up a flaming pan you may be burned DO NOT USE WATER including wet dishcloths or towels as a violent steam explosion may occur Functions Power Pack Control A Light ON OFF button B Blower Speed 1 low or OFF C Blower Speed 2 medium D Blower Speed 3 high E Blower Speed 4 intensive F 10 Minute Timer Filter requires washing indicator after 30 hours of use all the but tons will light up to remind you that the grease filter should be cleaned Follow the instructions for cleaning filters in this booklet Once the grease filters have been cleaned and replaced reset by pressing the timer button F Do not rely solely on this indicator Generally the grease filter should be washed on a regular basis to avoid grease filter fires The blower should be turned on for approximately 5 minutes before cooking in order to establish air currents upward through the hood Use the low speeds for normal use and the higher speeds for strong odors and fumes MAINTENANCE The range hood should provide many years of trouble free use provided it is properly maintained Be sure the lights are cool before cleaning the hood they are halogen and become extremely hot Cleaning the Filter The aluminium mesh filters should be washed by hand or in the dishwasher as reguired Damaged and worn filters must
11. ow by up to 50 Always fasten connections with WARNING Do not vent this sheet metal screws and tape all appliance into any other ductwork joints with certified Silver Tape or spaces between walls ceilings Duct Tape Do not use screws to attics garages or any other confined fasten ductwork to the hood only space use tape as the screws will stop the dampers from opening and your External Venting Requirements hood will not work This hood re quires a 6 round duct outlet You When planning new ductwork always Can increase the duct size of the look for the most direct route to the duct run but never decrease it Use outside Venting can be done through the shortest and most direct route the roof or directly through the back possible Always wherever possi outside wall See Figure 1 and 2 ble reduce the number of Only use rigid type metal ducting transitions and turns with as few plastic ducting is generally not sharp angles as possible Not applicable if the range hood is used in re circulating mode Figure 1 Figure 2 1 Two staggered 45 degree angles are better than one 90 degree Make these turns as far away from the motor exhaust as possible with as much space between each bend Duct Run Calculation The maximum duct run before effecting the performance of the Maximum Run 6 or 3 1 4 x 10 duct Deduct Each 90 elbow used Each 45 elbow used Each 6 or 3 1 4 x 10 duct Transition used
12. rds otherwise it will be difficult to remove it later for replacement A short length of ductwork must be connected from the exhaust outlet on the fan to wherever the air is to be exhausted Allow sufficient space to connect the ductwork to the top of the exhaust outlet on the fan housing Do not fix the ducting to the range hood exhaust outlet with screws use duct tape Duct tape should be used on all joints OPERATING PROCEDURES Read all the instructions before operating the appliance Save these instructions for future reference General Advice Ensure that the grease filters are in place Without these components operating blowers could catch on to hair fingers and loose clothing Keep fan filters and surfaces clean of grease and fat Always turn hood fan ON when cooking NEVER leave cooking unattended NEVER dispose cigarette ashes ignitable substances or any foreign objects into blowers Cooking that generates flame is not recommended as this hood is equipped with a thermal overload that will shut down the motor if it senses excessive heat When frying oil in the pan can easily overheat and ignite Heat oil slowly in an appropriately sized pot covering the entire burner to reduce the risk of boiling over and burning In the event of a range top grease fire observe the following Switch OFF the range hood Turn off the cook top then smother flames with a close fitting lid cookie sheet or other
13. taple Invoice Here Sirius Range Hoods USA CANADA SIRIUS RANGE HOODS USA LTD SIRIUS RANGE HOODS LTD 1051 Clinton Street 1252 Speers Road Unit 11 Buffalo NY 14206 Oakville ON L6L 5N9 Telephone Toll Free 866 528 4987 Telephone 905 257 0046 Fax Toll Free 866 365 9204 Fax 905 847 0330 www siriushoods com Email info siriushoods com