Siemens X005 User's Manual
Contents
1. Blitzductor VT AD 24V type no 918 402 is used Manufacturer DEHN SOHNE GmbH Co KG Hans Dehn Str 1 Postfach 1640 D 92306 Neumarkt Germany Note The specified approvals apply only when the corresponding mark is printed on the product Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A 2 1 Network Topologies 3 1 Network Topologies Switching technology allows extensive networks to be set up with numerous nodes and simplifies network expansion Which network topologies can be implemented With the SCALANCE X005 device bus and star topologies can be implemented Bus Topology PC with S7 200 with Panel PC CP 1613 A2 CP 243 1 FI CP 1613 A2 ES Fi er gn Es Lee S7 200 with i CP 243 1 ESCH d E E Gun n 87 300 with ti m illl LE CP 343 1 dme zd es BI I SCALANCE ER ch scALANCExoo5 EN IPC with prir 005 IPC with gra M CP 1613 A2 CP 1613 A2 Industrial Ethernet G WD Son Figure 3 1 Bus topology with SCALANCE X005 Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A 3 1 3 2 Network Topologies 3 1 Network Topologies Star Topology PC with CP 161342 TT Switch S7 200 with CP 243 1 CP 343 1 1 TET IPC with Panel PC CP 1613 A2 GEI XX 30038 Figure 3 2 Star topology with SCALANCE X005 Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A Product Characteristics 4 4 1 Components of the SC
2. Die angegebenen Zulassungen gelten erst dann als erteilt wenn auf dem Produkt eine entsprechende Kennzeichnung angebracht ist Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 2 1 Netztopologien 3 1 Netztopologien Die Switching Technologie erm glicht den Aufbau ausgedehnter Netze mit mehreren Teilnehmern und vereinfacht die Netzerweiterung Welche Netztopologien k nnen realisiert werden Mit dem Ger t SCALANCE X005 k nnen Linien und Sterntopologien realisiert werden Linientopologie PC mit S7 200 mit CP 1613 A2 CP 243 1 m PC mit BH CP 1613 A2 i E P S7 200 mit CP 243 1 ETT p Lug d Dr e g Sie f ji HN n J H i la fl IF Bil SCALANGE ha IPC mit fur X005 IPC mit CP 1613A2 Industrial Ethernet Bild 3 1 Linientopologie mit SCALANCE X005 Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 000001 CP 1613 A2 Panel PC S7 300 mit CP 343 1 wt HM SCALANCE xoo5 GH GIK IOAK 30040 Netztopologien 3 1 Netztopologien Sterntopologie PC mit CP 1613A2 ETT Switch SCALANCE X005 7 200 mit CP 243 1 CP 1613 A2 Bild 3 2 Sterntopologie mit SCALANCE X005 3 2 Leg G Kin XX 30038 Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A Produkteigenschaften 4 4 1 SCALANCE X005 Lieferumfang Was wird mit dem SCALANCE X005 ausgeliefert e Ger t SCALANCE X005 e 2 p
3. TP cables 0 100 m Industrial Ethernet FC TP standard cable with IE FC RJ 45 plug 180 Or over Industrial Ethernet FC outlet RJ 45 with O 90 m Industrial Ethernet FC TP standard cable 10 m TP cord Industrial Ethernet FC TP marine trailing cable with IE FC RJ 45 plug 180 Or 0 75 m Industrial Ethernet FC TP marine trailing cable 10 m TP cord Aging time 375 seconds Industrial Ethernet SCALANCE X005 4 6 Commissioning Manual A2B00051528A Product Characteristics 4 7 SCALANCE X005 Technical Specifications Permitted Environmental Conditions EMC Operating temperature OPC to 65 C Storage transport temperature 40 C to 80 C Relative humidity in operation 95 no condensation Operating altitude 2000 m at max 46 C ambient temperature 9000 m at max 40 C ambient temperature EN 61000 6 2 Class A replaces EN 50081 2 Class A RF interference level EN 61000 6 2 Class B with split toroidal core on the lines Manufacturer W rth Elektronik type 742 711 31 Noise immunity EN 61000 6 4 replaces EN 50082 2 Degree of protection IP 30 Approvals c UL us UL 60950 Corresponds to CSA C22 2 No 60950 C TICK AS NZS 2064 Class A CE EN 61000 6 2 EN 61000 6 4 replaces EN 50081 2 Dimensions W x H x D in mm Installation options DIN rail S7 300 standard rail Wall mounting Order Numbers SCALANCE X005 66K5005 0BA00 1AA3 Industrial Ethernet TP and Fiber Optic Netw
4. f r deren Zwecke die Rechte der Inhaber verletzen k nnen Copyright Siemens AG 2004 All rights reserved Haftungsausschluss Weitergabe sowie Vervielfaltigung dieser Unterlage Verwertung und Mitteilung ihres Wir haben den Inhalt der Druckschrift auf bereinstimmung mit der beschriebenen Hard Inhalts ist nicht gestattet soweit nicht ausdr cklich zugestanden Zuwiderhandlungen und Software gepr ft Dennoch k nnen Abweichungen nicht ausgeschlossen werden so verpflichten zu Schadenersatz Alle Rechte vorbehalten insbesondere f r den Fall der dass wir f r die vollstandige bereinstimmung keine Gew hr bernehmen Die Angaben in Patenterteilung oder GM Eintragung dieser Druckschrift werden regelm ig berpr ft notwendige Korrekturen sind in den nachfolgenden Auflagen enthalten Siemens AG Automation and Drives Siemens AG 2005 Postfach 4848 D 90327 N rnberg Technische Anderungen bleiben vorbehalten Siemens Aktiengesellschaft A2B00051528A Inhaltsverzeichnis 1 NOR WOR tee CE 1 1 1 1 Mio o 1 1 A le Le une EL TUUM 2 1 2 1 lg Ui gla DL o q E 2 1 NSTEZIOPOLOGIEN re RR Mo e o D E D mmc 3 1 3 1 IS ZOOL ON EN ee es A T 3 1 Seel Ee Der EE 4 1 4 1 SCALANGE X005 Ltreterumfantjfs s Ee eg 4 1 4 2 SCALANCE X005 Auspacken und bruten 4 1 4 3 SCALANCE X005 Produkteigenschaften eese seen nne 4 2 4 4 SCOALANGE X005 TPSScChHlttstellgti il o EE
5. not avoided could result in death or serious injury Caution gt bb used with the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in minor or moderate injury Caution used without the safety alert symbol indicates a potentially hazardous situation which if not avoided may result in property damage Notice used without the safety alert symbol indicates a potential situation which if not avoided may result in an undesirable result or state When several danger levels apply the notices of the highest level lower number are always displayed If a notice refers to personal damages with the safety alert symbol then another notice may be added warning of property damage Qualified Personnel The device system may only be set up and operated in conjunction with this documentation Only qualified personnel should be allowed to install and work on the equipment Only qualified personnel should be allowed to install and work on the equipment Qualified persons are defined as persons who are authorized to commission to earth and to tag circuits equipment and systems in accordance with established safety practices and standards Intended Use Please note the following N Warning This device and its components may only be used for the applications described in the catalog or technical description and only in connection with devices or components from other manufacturers approved o
6. te der Produktlinien SCALANCE X 100 bzw X 200 Bild 5 5 Stecken des IE FC RJ45 Plug 180 Der Haltekragen an der TP Schnittstelle des SCALANCE X005 gew hrleistet durch den Formschluss und die Verrastung mit dem PROFINET konformen Steckverbinder IE FC RJ45 Plug 180 einen robusten industriegerechten Teilnehmeranschluss der eine Zug und Biegeentlastung der Twisted Pair Buchse bietet Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 5 7 Montage und Wartung 5 7 Wartung Ziehen des IE FC RJ45 Plug 180 4 Entriegeln Sie den IE FC RJ45 Plug 180 durch leichtes Andr cken der Verrastung um den Plug zu ziehen Bild 5 6 Entriegelung des RJ45 Plug Sollte aus Platzgr nden eine Entriegelung per Hand nicht m glich sein k nnen Sie die Entriegelung auch mit einem 2 5 mm Schraubendreher l sen Danach k nnen Sie den IE FC RJ45 Plug 180 aus der Twisted Pair Buchse ziehen 5 7 Wartung Wartung Bitte senden Sie das Ger t im Fehlerfall an Ihre SIEMENS Dienststelle zur Reparatur ein Eine Reparatur vor Ort ist nicht m glich Industrial Ethernet SCALANCE X005 5 8 Inbetriebnahmehandbuch A2B00051528A Hinweise zur CE Kennzeichnung 6 6 1 Hinweise zur CE Kennzeichnung Produktbezeichnung SIMATIC NET SCALANCE X005 6GK5005 0BA00 1AA3 EMV Richtlinie Richtlinie 89 336 EWG Elektromagnetische Vertraglichkeit Einsatzbereich Das Produkt ist ausgelegt fur den Einsatz im Industriebereich Einsatzbereich Anford
7. 4 3 4 5 SCALANCE X005 SpannunGSversorgung nnrir ai a 4 5 4 6 SCALANGE XO05 Anzeigen ans ces c 4 5 4 SCALANGE X005 Technische Daten De E Ee 4 6 Montage Una Warnung ca m 5 1 9 1 MOMNta de oda 5 1 9 2 gloire Dass A Ad 0 2 9 3 Prollsehienenmomta de resta sans 5 3 5 4 Ee ger e 5 4 9 9 siye iare e acess ed REPRE 5 5 9 6 Montage des IE Standard Cable ia beri bdo b cox Exe an Deom Eee Iria Eds 5 6 5 7 A T TNNT 5 8 Hinweise zur CE Kennzeichnung cccsssccccesececeecceesecceaseeesaueceeeueeeseaeeeeeauecesaueceseaeeessaeeesnagessesenaneeees 6 1 6 1 Hinweise zur CE Kennzeichnung c ccccccsseecccececceesecccsaseeeecseseecseuseeeeseageeessuaueeeesauseeseseaes 6 1 BET en Le 7 1 7 1 Literatur verzelcDHls sese ehe oae hei a a m assu oat liad ities 7 1 MAIS ZOIC A ae ea 8 1 Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A iii Vorwort 1 1 4 Vorwort Zweck der Inbetriebnahmeanleitung Diese Inbetriebnahmeanleitung unterst tzt Sie bei der Inbetriebnahme des unmanaged Industrial Ethernet Entry Level Switches SCALANCE X005 G ltigkeitsbereich dieser Inbetriebnahmeanleitung Diese Inbetriebnahmeanleitung ist f r folgende Gerate g ltig SIMATIC NET SCALANCE X005 6GK5005 0BAO00 1AA3 Weiterf hrende Dokumentation Im Handbuch SIMATIC NET Industrial Ethernet Twisted Pair und Fiber Optic Netze erhalten Sie zusatzliche Hinweise zu weiteren SIMATIC NET Produkten die Sie gemeinsam mi
8. ALANCE X005 Product What ships with the SCALANCE X005 e SCALANCE X005 device e 2 pin plug in terminal block e Commissioning manual this document 4 2 SCALANCE X005 Unpacking and Checking Unpacking Checking 1 Make sure that the package is complete 2 Check all parts for transport damage N Warning Do not use any parts that show evidence of damage N Warning If the SCALANCE X005 device is operated in ambient temperatures between 60 C 65 C the temperature of the device housing may be higher than 65 C The subject unit must be located in a Restricted Access Location where access can only be gained by SERVICE PERSONNEL or by USERS who have been instructed about the reasons for the restrictions applied to the location and about any precautions that shall be taken when operated in an ambient temperature of 60 C 65 C Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A 4 1 Product Characteristics 4 3 SCALANCE X005 Product Characteristics 4 3 SCALANCE X005 Product Characteristics Possible Attachments SCALANCE X005 features five RJ 45 jacks for the connection of DTEs or other network segments Figure 4 1 SCALANCE X005 Industrial Ethernet SCALANCE X005 4 2 Commissioning Manual A2B00051528A Product Characteristics 4 4 SCALANCE X005 TP Ports 4 4 SCALANCE X005 TP Ports Connector Pinout RJ 45 jack 8 6 5 4 3 2 1 Figure 4 2 RJ 45 connector pinout Pin number Pinou
9. Beim SCALANCE X005 sind die Twisted Pair Schnittstellen als RJ45 Buchse mit MDI X Belegung Medium Dependent Interface Autocrossover einer Netzkomponente ausgef hrt Achtung An dem TP Port in RJ45 Ausf hrung k nnen TP Cords oder TP XP Cords mit einer Maximall nge von 10 m angeschlossen werden Mit den IE FC Cables und IE FC RJ45 Plugs 180 ist je nach Leitungstyp eine gesamte Leitungsl nge von maximal 100 m zwischen zwei Ger ten zul ssig Autonegotiation Unter Autonegotiation versteht man die automatische Erkennung der Funktionalit t der Schnittstelle der Gegenseite Mit dem Autonegotiation Verfahren k nnen Repeater oder Endger te feststellen ber welche Funktionalit t die Schnittstelle der Gegenseite verf gt so Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 4 3 Produkteigenschaften 4 4 SCALANCE X005 TP Schnittstellen dass ein automatisches Konfigurieren unterschiedlicher Gerate m glich ist Das Autonegotiation Verfahren erm glicht es zwei Komponenten die an einem Link Segment angeschlossen sind untereinander Parameter auszutauschen und sich mit Hilfe dieser Parameter auf die jeweils unterst tzten Eckwerte der Kommunikation einzustellen Hinweis Ger te die kein Autonegotation unterst tzen m ssen auf 100 MBit Halbduplex bzw 10 MBit Halbduplex festeingestellt werden Auto polarity exchange Ist das Receive Leitungspaar falsch angeschlossen RD und RD vertauscht wird
10. CE X005 Commissioning Manual A2B00051528A 5 3 Installation and Maintenance 5 4 Wall Mounting SIEMENS SCALANCE X005 SIEMENS Simatic S7 nn 6ES7 390 1AE80 0AAO PROFILSCHIENE es 482 6 MM M DC 24V 0 104 i MAE d ae e Figure 5 3 SCALANCE X005 installation on a SIMATIC S7 300 standard rail 5 4 Wall Mounting Wall Mounting 1 Use four wall plugs 6 mm diameter and 30 mm long 2 To attach the device use screws with a diameter of 3 5 mm and a length of 40 mm For exact dimensions please observe the dimension drawings in the Chapter Dimension Drawing of the instructions Note The wall mounting must be capable of supporting at least four times the weight of the device Industrial Ethernet SCALANCE X005 5 4 Commissioning Manual A2B00051528A Installation and Maintenance 5 5 Grounding 5 5 Grounding Installation on a DIN Rail The device is grounded over the DIN rail S7 Standard Rail The device is grounded over its rear panel and the neck collar screw Wall Mounting The device is grounded by the securing screw in the unpainted hole Please note that SCALANCE X005 must be grounded over one securing screw with minimum resistance If the device is mounted on a non conducting surface it is required to install a grounding cable The grounding cable is not included in the delivery Connect the unpainted surface of the device to the next grounding point via the grounding cable Industria
11. SIEMENS SIMATIC NET Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch 10 2005 A2B00051528A Deutsch English Erzeugnisstand 01 Vorwort Einf hrung Netztopologien Produkteigenschaften Montage und Wartung Hinweise zur CE Kennzeichnung Literaturverzeichnis Ma zeichnung 0 N O O IA W IN Sicherheitstechnische Hinweise Dieses Handbuch enthalt Hinweise die Sie zu Ihrer pers nlichen Sicherheit sowie zur Vermeidung von Sachschaden beachten m ssen Die Hinweise zu Ihrer pers nlichen Sicherheit sind durch ein Warndreieck hervorgehoben Hinweise zu alleinigen Sachschaden stehen ohne Warndreieck Je nach Gefahrdungsstufe werden die Warnhinweise in abnehmender Reihenfolge wie folgt dargestellt Gefahr bedeutet dass Tod oder schwere K rperverletzung eintreten wird wenn die entsprechenden Vorsichtsma nahmen nicht getroffen werden Warnung bedeutet dass Tod oder schwere K rperverletzung eintreten kann wenn die entsprechenden Vorsichtsma nahmen nicht getroffen werden Vorsicht mit Warndreieck bedeutet dass eine leichte K rperverletzung eintreten kann wenn die entsprechenden Vorsichtsma nahmen nicht getroffen werden Vorsicht ohne Warndreieck bedeutet dass Sachschaden eintreten kann wenn die entsprechenden Vorsichtsma nahmen nicht getroffen werden Achtung bedeutet dass ein unerw nschtes Ergebnis oder Zustand eintreten kann wenn der entsprechende Hinweis nicht beachtet wird B
12. chten Sie bei Installation und Betrieb die Aufbaurichtlinien und Sicherheitshinweise die in dieser Beschreibung sowie im Handbuch SIMATIC NET Industrial Ethernet Twisted Pair und Fiber Optic Netze 2 beschrieben sind Hinweis Sch tzen Sie das Ger t durch geeignete Abschattung gegen direktes Sonnenlicht Dies vermeidet eine unerw nschte Erwarmung des Gerates und verhindert fr hzeitige Alterung von Gerat und Verkabelung Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 5 1 Montage und Wartung 5 2 Hutschienenmontage 5 2 Hutschienenmontage Montage Montieren Sie den SCALANCE X005 auf einer 35 mm Hutschiene nach DIN EN 50022 1 Hangen Sie die obere Rastf hrung des Gerats in die Hutschiene ein und dr cken Sie es nach unten gegen die Hutschiene bis zum Einrasten 2 Montieren Sie die elektrischen Anschlussleitungen om amp Bild 5 1 SCALANCE X005 Montage auf einer DIN Hutschiene 35 mm Demontage Um den SCALANCE X005 von der Hutschiene abzunehmen 1 Demontieren Sie zunachst die TP Leitungen und ziehen Sie den Klemmblock f r die Spannungsversorgung ab 2 Entriegeln Sie mit einem Schraubendreher die Hutschienenverrastung an der Unterseite des Ger ts und heben Sie danach das Ger t unten von der Hutschiene weg Industrial Ethernet SCALANCE X005 5 2 Inbetriebnahmehandbuch A2B00051528A Montage und Wartung 5 3 Profilschienenmontage a amp Bild 5 2 SCALANCE X005 Demontage v
13. die Polaritat automatisch angepasst Hinweis Der SCALANCE X005 ist ein Plug and Play Ger t das f r die Inbetriebnahme keine Einstellung ben tigt MDI MDIX Autocrossover Funktion Die MDI MDIX Autocrossover Funktion bietet den Vorteil einer durchg ngigen Verkabelung ohne dass externe gekreuzte Ethernetkabel erforderlich sind Fehlfunktionen bei vertauschten Send und Empfangsleitungen werden dadurch verhindert Die Installation wird dadurch f r den Anwender wesentlich vereinfacht Das Gerat SCALANCE X005 unterst tzt die MDI MDIX Autocrossover Funktion Achtung Fest konfigurierte Schnittstellen von Partnerstationen m ssen auf 100Mbit Halbduplex oder 10Mbit s Halbduplex eingestellt sein Achtung Bitte beachten Sie dass eine direkte Verbindung zweier Ports oder eine unbeabsichtigte Verbindung ber mehrere Switches hinweg zu einer unzulassigen Schleifenbildung f hrt die zu Netz berlast und Netzausfallen f hren kann Industrial Ethernet SCALANCE X005 4 4 Inbetriebnahmehandbuch A2B00051528A Produkteigenschaften 4 5 SCALANCE X005 Spannungsversorgung 4 5 SCALANCE X005 Spannungsversorgung Spannungsversorgung Der Anschluss der Spannungsversorgung erfolgt ber einen 2 poligen steckbaren Klemmenblock Die Spannungsversorgung ist hochohmig mit dem Geh use verbunden um einen erdfreien Aufbau zu erm glichen Die Spannungsversorgung ist potentialgebunden DC 24V 0 104 005 0BA00 1AA3 Bild 4 3 Spannungsve
14. e Die Erdung erfolgt ber die Hutschiene S7 Profilschiene Die Erdung erfolgt ber die Ger ter ckseite und die Halsschraube Wandmontage Die Erdung erfolgt durch die Befestigungsschraube ber die lackfreie Bohrung Beachten Sie bitte dass der SCALANCE X005 ber eine Befestigungsschraube m glichst niederohmig geerdet werden muss Wird das Ger t auf einem nicht leitenden Untergrund montiert muss ein Erdungskabel montiert werden Das Erdungskabel ist nicht im Lieferumfang enthalten Verbinden Sie die lackfreie Fl che des Ger tes ber das Erdungskabel mit dem n chstgelegenen Erdungspunkt Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 5 5 Montage und Wartung 5 6 Montage des IE FC Standard Cable 5 6 Montage des IE FC Standard Cable So montieren Sie den IE FC RJ45 Plug 180 an das IE FC Standard Cable Die Hinweise zur Montage entnehmen Sie bitte der Anweisung die dem IE FC RJ45 Plug 180 beiliegt Die robusten und industriegerechten Teilnehmeranschl sse mit PROFINET konformen Steckverbindern bieten durch die Verrastung am Geh use eine zusatzliche Zug und Biegeentlastung Bild 5 4 IE FC RJ45 Plug 180 Industrial Ethernet SCALANCE X005 5 6 Inbetriebnahmehandbuch A2B00051528A Montage und Wartung 5 6 Montage des IE FC Standard Cable Stecken des IE FC RJ45 Plug 180 3 Stecken Sie den IE FC RJ45 Plug 180 bis zum Verrasten in die Twisted Pair Schnittstelle des SCALANCE X005 bzw der Ger
15. e pH E J 2 1 INGIWOMK eieiei ie oem 3 1 3 1 Network LODOIOGIES PC ete 3 1 Product narcisos e en ts MM I ee ee ea aca 4 1 4 1 Components of the SCALANCE X005 broduct 4 1 4 2 SCALANCE X005 Unpacking and Checkmg 4 1 4 3 SCALANCE X005 Product CharacteristiCS ccocooooccoccoocnoccccnnonoconononnncanoncnnanononononnnnnnnanennnss 4 2 4 4 SCALANCE X009 TP ROMS asta Ee 4 3 4 5 SGALANCE X005 POWer ee EE 4 5 4 6 SEAFANGE ln RE 4 5 4 7 SCALANCE X005 Technical Specifications 00nnn0annoannnnnnenennnnnnennnonnenrnnnsrrrnnrrrrenrrserrrnnrrrnne 4 6 Installat on and Maintenance een 5 1 5 1 inier 5 1 5 2 Installallon on a DIN Al nee re 9 2 9 3 Installation on a Standard E EEN 9 3 9 4 Valdunciel a blicas 5 4 5 9 Ee Late plo APR O oo o A A A 5 5 9 6 Assembling the IE FC Standard Cable EEN 5 6 5 7 fleien te T 9 8 Notes on the CE Mark za ae A ae 6 1 6 1 Notes On he GE Marker aaa a eins 6 1 References idos 7 1 7 1 aie mc M 7 1 DIMENSION DRAWING eR 8 1 Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A iii Preface 1 1 1 Preface Purpose of the Commissioning Manual This commissioning manual supports you when commissioning the unmanaged Industrial Ethernet entry level switch SCALANCE X005 Validity of this Commissioning Manual This commissioning manual
16. eim Auftreten mehrerer Gef hrdungsstufen wird immer der Warnhinweis zur jeweils h chsten Stufe verwendet Wenn in einem Warnhinweis mit dem Warndreieck vor Personensch den gewarnt wird dann kann im selben Warnhinweis zus tzlich eine Warnung vor Sachsch den angef gt sein Qualifiziertes Personal Das zugeh rige Ger t System darf nur in Verbindung mit dieser Dokumentation eingerichtet und betrieben werden Inbetriebsetzung und Betrieb eines Ger tes Systems d rfen nur von qualifiziertem Personal vorgenommen werden Qualifiziertes Personal im Sinne der sicherheitstechnischen Hinweise dieser Dokumentation sind Personen die die Berechtigung haben Ger te Systeme und Stromkreise gem den Standards der Sicherheitstechnik in Betrieb zu nehmen zu erden und zu kennzeichnen Bestimmungsgem er Gebrauch Beachten Sie folgendes Warnung Das Ger t darf nur f r die im Katalog und in der technischen Beschreibung vorgesehenen Einsatzfalle und nur in Verbindung mit von Siemens empfohlenen bzw zugelassenen Fremdger ten und komponenten verwendet werden Der einwandfreie und sichere Betrieb des Produktes setzt sachgem en Transport sachgem e Lagerung Aufstellung und Montage sowie sorgfaltige Bedienung und Instandhaltung voraus Marken Alle mit dem Schutzrechtsvermerk amp gekennzeichneten Bezeichnungen sind eingetragene Marken der Siemens AG Die brigen Bezeichnungen in dieser Schrift k nnen Marken sein deren Benutzung durch Dritte
17. erungen an St raussendung St rfestigkeit Industriebetrieb EN 61000 6 4 2001 EN 61000 6 2 2001 ersetzt EN 50082 2 ersetzt EN 5008 1 2 Aufbaurichtlinien beachten Das Produkt erf llt die Anforderungen wenn Sie bei Installation und Betrieb die Aufbaurichtlinien und Sicherheitshinweise einhalten die in dieser Beschreibung sowie im Handbuch SIMATIC NET Industrial Ethernet TP und Fiber Optic Netze 1 beschrieben sind Konformitatserklarung Die EG Konformitatserklarung wird gem den oben genannten EG Richtlinien f r die zustandigen Behorden zur Verf gung gehalten bei Siemens Aktiengesellschaft Bereich Automatisierungs und Antriebstechnik Industrielle Kommunikation A amp D PT2 Postfach 4848 D 90327 N rnberg Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 6 1 Hinweise zur CE Kennzeichnung 6 1 Hinweise zur CE Kennzeichnung Hinweise f r Hersteller von Maschinen Das Produkt ist keine Maschine im Sinne der EG Richtlinie Maschinen Es gibt deshalb f r dieses Produkt keine Konformitatserklarung bez glich der EG Richtlinie Maschinen 89 392 EWK Ist das Produkt Teil der Ausr stung einer Maschine muss es vom Maschinenhersteller in das Verfahren zur Konformitatserklarung einbezogen werden Industrial Ethernet SCALANCE X005 6 2 Inbetriebnahmehandbuch A2B00051528A Literaturverzeichnis T 1 Literaturverzeichnis Weiterf hrende Literatur 1 SIMATIC NET Industrial Twisted Pa
18. essing the latching to unplug the plug Figure 5 6 Unlatching the RJ 45 plug If for lack of space a manual unlatching is not possible you can also unlatch the plug with a 2 5 mm screwdriver Subsequently you can unplug the IE FC RJ 45 plug 180 from the twisted pair port 5 Maintenance Maintenance If a fault develops please send the device to your SIEMENS service center for repair Repairs on site are not possible Industrial Ethernet SCALANCE X005 5 8 Commissioning Manual A2B00051528A Notes on the CE Mark 6 6 1 Notes on the CE Mark Product Name SIMATIC NET SCALANCE X005 6GK5005 0BA00 1AA3 EMC Directive 89 336 EEC Electromagnetic Compatibility Area of Application The product is designed for use in an industrial environment nis mission Nosemmenty Industrial operation EN 61000 6 4 2001 EN 61000 6 2 2001 replaces EN 50082 2 replaces EN 50081 2 Installation Guidelines The product meets the requirements if you keep to the installation instructions and safety related notices as described here and in the manual SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks 1 when installing and operating the device Conformity Certificates The EU declaration of conformity is available for the responsible authorities according to the above mentioned EU directive at the following address Siemens Aktiengesellschaft Bereich Automatisierungs und Antriebstechnik Indust
19. geraten oder oxRJ45 Buchsen mit MDI X Belegung 10 100 Netzkomponenten ber Twisted Pair Mbit s Halb Vollduplex Anschluss f r Spannungsversorgung 1x2poliger steckbarer Klemmenblock Elektrische Daten Versorgungsspannung Einspeisung DC 18 32V Sicherheitskleinspannung SELV Verlustleistung bei DC 24 V typ 2W Stromaufnahme bei Nennspannung typ 80 mA berstromschutz am Eingang PTC Resetable Fuse 0 5 A 60 V Zulassige Leitungsl ngen Anschluss ber Industrial Ethernet FC TP Leitungen 0 100 m Industrial Ethernet FC TP Standard Cable mit IE FC RJ45 Plug 180 oder ber Industrial Ethernet FC Outlet RJ45 mit 0 90 m Industrial Ethernet FC TP Standard Cable 10 m TP Cord Industrial Ethernet FC TPMarine Trailing Cable mit IE FC RJ45 Plug 180 oder 0 75 m Industrial Ethernet FC TP Marine Trailing Cable 10 m TP Cord Aging Time 3 5 Sekunden Industrial Ethernet SCALANCE X005 4 6 Inbetriebnahmehandbuch A2B00051528A Produkteigenschaften 4 7 SCALANCE X005 Technische Daten Zul ssige Umgebungsbedingungen EMV Betriebstemperatur 0 C bis 65 C Lager Transporttemperatur 40 C bis 80 C Relative Feuchte im Betrieb 9596 nicht kondensierend Betriebsh he 2000 m bei max 46 C Umbebungstemperatur 9000 m bei max 40 C Umgebungstemperatur EN 61000 6 2 Class A ersetzt EN 5008 1 2 Class A Funkst rgrad EN 61000 6 2 Class B mit Klappferrit auf den Leitungen Hersteller W rth Elektron
20. ik Typ 742 711 31 St rfestigkeit EN 61000 6 4 ersetzt EN 50082 2 Schutzart IP 30 Zulassungen c UL us UL 60950 Entspricht CSA C22 2 Nr 60950 AS NZS 2064 Class A C TICK ersetzt EN 50081 2 MTBF Konstruktiver Aufbau Ma e B x Hx T in mm 140 x 125 x 124 Gewicht in g Montagemoglichkeiten Hutschiene S7 300 Profilschiene Wandmontage Bestellnummern SCALANCE X005 66K5005 0BA00 1AA3 Handbuch Industrial Ethernet TP und Fiber 6GK1970 1BA10 OAAO Optic Netze IE FC RJ45 Plug 180 Packungseinheit 10 St ck Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 4 7 Produkteigenschaften 4 7 SCALANCE X005 Technische Daten Hinweis Die Anzahl der angeschlossenen Industrial Ethernet Switches SCALANCE X beeinflusst die Telegrammdurchlaufzeit Beim Durchlauf eines Telegramms durch den SCALANCE X005 wird dieses durch die Store amp Forward Funktion des Switch verz gert bei 64 Byte Telegrammlange um circa 10 us bei 100 Mbit s bei 1500 Byte Telegrammlange um circa 130 us bei 100 Mbit s Das hei t je mehr SCALANCE X005 durchlaufen werden desto h her ist die Telegrammlaufzeit Industrial Ethernet SCALANCE X005 4 8 Inbetriebnahmehandbuch A2B00051528A Montage und Wartung 5 5 1 Montage Montagearten Der SCALANCE X005 l sst mehrere Montagearten zu e Montage auf 35 mm DIN Hutschiene e Montage auf einer SIMATIC 87 300 Profilschiene e Wandmontage Hinweis Bea
21. ir and Fiber Optic Netze Ausgabe 05 2001 Bestellnummern 6GK1970 1BA10 0AAO0 deutsch 6GK1970 1BA10 0AA1 englisch 66GK1970 1BA10 0AA2 franz sisch 66GK1970 1BA10 0AAA italienisch 2 Weiterf hrende Informationen zum SCALANCE System sind im Internet unter WWW Siemens com scalance verf gbar Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 7 1 Ma zeichnung Bild 8 1 Bohrschablone Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A E RE E ENANOS BEE Pl gt BOE ER 15 8 1 SIEMENS SIMATIC NET Industrial Ethernet SCALANCE X005 Commissioning Manual 10 2005 A2B00051528A German English Product Version 01 Preface Introduction Network Topologies Product Characteristics Installation and Maintenance Notes on the CE Mark References Dimension Drawing 0 O Oc Bb W IN Safety Guidelines This manual contains notices which you should observe to ensure your own personal safety as well as to avoid property damage The notices referring to your personal safety are highlighted in the manual by a safety alert symbol notices referring to property damage only have no safety alert symbol Depending on the danger level the notices are displayed in descending order as follows Danger indicates an imminently hazardous situation which if not avoided will result in death or serious injury Warning indicates a potentially hazardous situation which if
22. is valid for the following devices SIMATIC NET SCALANCE X005 6GK5005 OBADO 1AA3 Further Documentation The SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks manual contains additional information on other SIMATIC NET products that you can operate along with the SCALANCE X005 switch in an Industrial Ethernet network You can download this network manual from Customer Support on the Internet under entry number 1172207 Audience This commissioning manual is intended for personnel involved in the commissioning of the SCALANCE X005 switch in a network Standards and Approvals The SCALANCE X005 device meets the requirements for the CE mark For detailed information refer to the Chapter Notes on the CE Mark Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A 1 1 2 Introduction 2 1 Introduction This chapter provides you with an overview of the functions of the unmanaged Industrial Ethernet entry level switch SCALANCE X005 What Is Possible The SCALANCE X005 switch enables the cost effective installation of small Industrial Ethernet bus or star structures with switching functionality The devices are designed for installation in a switching cubicle Note It is not possible to use the SCALANCE X005 switch in a redundant ring since it does not support the redundancy function Note The requirements of EN61000 4 5 surge test on power supply lines are met only when a
23. l Ethernet SCALANCE X005 Commissioning Manual A2B00051528A 5 5 Installation and Maintenance 5 6 Assembling the IE FC Standard Cable 5 6 Assembling the IE FC Standard Cable Assemble the IE FC RJ 45 plug 180 and the IE FC standard cable as follows For information on the assembly please refer to the instructions that ship with the IE FC RJ 45 plug 180 The robust connectors of the nodes are designed for industry and are PROFINET compliant Due to the locking mechanism on the casing they provide additional strain and torsion relief Figure 5 4 IE FC RJ 45 plug 180 Industrial Ethernet SCALANCE X005 5 6 Commissioning Manual A2B00051528A Installation and Maintenance 5 6 Assembling the IE FC Standard Cable Plugging the IE FC RJ 45 Plug 180 3 Plug the IE FC RJ 45 plug 180 in the twisted pair port of SCALANCE X005 or of the devices of the product lines SCALANCE X 100 or X 200 until it snaps into place Figure 5 5 Plugging the IE FC RJ 45 plug 180 Due to the closing shape and the latching with the PROFINET compliant connector IE FC RJ 45 plug 180 the sleeve at the TP port of SCALANCE X005 ensures a robust industry standard node connection which provides additional strain and torsion relief of the twisted pair port Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A 5 Installation and Maintenance 5 7 Maintenance Unplugging the IE FC RJ 45 Plug 180 4 Unlatch the IE FC RJ 45 plug 180 by slightly pr
24. oliger steckbarer Klemmenblock e Inbetrieonahmehandbuch dieses Dokument 4 2 SCALANCE X005 Auspacken und Pr fen Auspacken Pr fen 1 berpr fen Sie das Paket auf Vollstandigkeit 2 berpr fen Sie die Einzelteile auf Transportsch den N Warnung Nehmen Sie nur unbeschadigte Teile in Betrieb N Warnung Wird das Ger t SCALANCE X005 bei Umgebungstemperaturen zwischen 60 C 65 C betrieben kann die Geh usetemperatur des Ger ts ber 65 C liegen Der Montageort des Ger tes muss deshalb so gew hlt werden dass nur qualifiziertes Service Personal oder geschulte Anwender darauf Zugriff haben und nur dann darf das Gerat bei einer Umgebungstemperatur von 60 C 65 C betrieben werden Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 4 1 Produkteigenschaften 4 3 SCALANCE X005 Produkteigenschaften 4 3 SCALANCE X005 Produkteigenschaften Anschlussm glichkeiten Der SCALANCE X005 verf gt ber f nf RJ45 Buchsen f r den Anschluss von Endger ten oder weiterer Netzsegmente Bild 4 1 SCALANCE X005 Industrial Ethernet SCALANCE X005 4 2 Inbetriebnahmehandbuch A2B00051528A 4 4 SCALANCE X005 TP Schnittstellen Steckerbelegung RJ45 Buchse 8 7 6 5 4 3 2 1 Bild 4 2 Pinnummer Belegung Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1 Steckerbelegung RJ45 n C n C TD n C n C TD RD RD Produkteigenschaften 4 4 SCALANCE X005 TP Schnittstellen
25. on einer DIN Hutschiene 35 mm 5 3 Profilschienenmontage Montage auf einer SIMATIC S7 300 Profilschiene 1 H ngen Sie die Geh usef hrung an der Oberseite des SCALANCE Gehauses in die S7 Profilschiene ein 2 Verschrauben Sie das Gerat SCALANCE X005 an der Unterseite der Profilschiene 3 Montieren Sie die elektrischen Anschlussleitungen Demontage 1 Demontieren Sie zunachst alle angeschlossenen Leitungen 2 L sen Sie die Verschraubungen an der Unterseite der Profilschienen und heben Sie danach das Ger t von der Profilschiene weg Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 5 3 Montage und Wartung 5 4 Wandmontage SIEMENS SCALANCE X005 SIEMENS Simatic S7 nn 6ES7 390 1AE80 0AA0 PROFILSCHIENE Be 482 6 MM M DC 24V 0 104 005 08AQQ us ram 2 Bild 5 3 SCALANCE X005 Montage auf einer SIMATIC S7 300 Profilschiene 5 4 Wandmontage Wandmontage 1 Verwenden Sie vier Wandd bel mit 6 mm Durchmesser und 30 mm L nge 2 Verwenden Sie zur Befestigung Schrauben mit 3 5 mm Durchmesser und 40 mm L nge F r genaue Ma e beachten Sie bitte die Ma zeichnungen im Kapitel Ma zeichnung der Anleitung Hinweis Die Wandbefestigung muss so ausgelegt sein dass sie mindestens das vierfache Eigengewicht des Ger ts tragen kann Industrial Ethernet SCALANCE X005 5 4 Inbetriebnahmehandbuch A2B00051528A Montage und Wartung 5 5 Erdung 5 5 Erdung Hutschienenmontag
26. orks manual IE FC blade cassettes 66K1901 1GB00 IE FC TP standard cable GP Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A 4 7 Product Characteristics 4 7 SCALANCE X005 Technical Specifications Note The number of connected SCALANCE X Industrial Ethernet switches influences the frame propagation time When a frame passes through SCALANCE X005 it is delayed by the store and forward function of the switch With a 64 byte frame length by approx 10 us at 100 Mbps With a 1500 byte frame length by approx 130 us at 100 Mbps This means that the more SCALANCE X005 devices are passed through the higher the frame propagation time will be Industrial Ethernet SCALANCE X005 4 8 Commissioning Manual A2B00051528A Installation and Maintenance 5 5 1 Installation Types of installation SCALANCE X005 can be installed in various ways e Installation on a 35 mm DIN rail e Installation on a SIMATIC S7 300 standard rail e Wall mounting Note When installing and operating the device keep to the installation instructions and safety related notices as described here and in the SIMATIC NET Industrial Ethernet Twisted Pair and Fiber Optic Networks 2 manual Note Protect the device against exposure to direct sunlight by suitable shadowing This avoids an undesired temperature rise of the device and prevents premature ageing of device and cabling Industrial Ethernet SCALANCE X005 Commissioning Man
27. r recommended by Siemens This product can only function correctly and safely if it is transported stored set up and installed correctly and operated and maintained as recommended Trademarks All designations marked with are registered trademarks of Siemens AG Other designations in this documentation might be trademarks which if used by third parties for their purposes might infringe upon the rights of the proprietors Copyright Siemens AG 2005 All rights reserved Disclaimer of Liability Reproduction transmission or use of this document or its contents is not permitted without We have checked the contents of this manual for agreement with the hardware and express written authority Offenders will be liable for damages All rights including rights software described Since deviations cannot be precluded entirely we cannot guarantee created by patent grant or registration of a utility model or design are reserved full agreement However the data in the manual are reviewed regularly and any necessary corrections will be included in subsequent editions Suggestions for improvement are welcomed Siemens AG Automation and Drives Group Siemens AG 2005 P O Box 4848 D 90327 Nuremberg Germany Technical data subject to change Siemens Aktiengesellschaft A2B00051528A Table of Contents Preiater RN 1 1 1 1 PGT ACG mort P 1 1 INITOGUCHON seem HDD TS 2 1 2 1 INKOQUCUON Pep
28. rielle Kommunikation A amp D PT2 Postfach 4848 D 90327 N rnberg Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A 6 1 Notes on the CE Mark 6 7 Notes on the CE Mark Notes for Manufacturers of Machines This product is not a machine in the sense of the EU directive on machines There is therefore no declaration of conformity for the EU directive on machines 89 392 EEC If the product is part of the equipment of a machine it must be included in the procedure for the declaration of conformity by the manufacturer of the machine Industrial Ethernet SCALANCE X005 6 2 Commissioning Manual A2B00051528A References 7 1 References Sources of Information and Other Documentation 1 SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks Edition 05 2001 Order numbers 6GK1970 1BA10 0AAD German 6GK1970 1BA10 0AA1 English 6GK1970 1BA10 0AA2 French 6GK1970 1BA10 0AA4 Italian 2 You will find further information on the SCALANCE system on the Internet at www siemens com scalance Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A 7 1 Dimension Drawing 40 Figure 8 1 Drilling template Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A EA E See Dii PA E SERIE 115 8 1
29. rsorgung Bild 4 4 Steckerbelegung Pinnummer Belegung Pin 1 M Masse Pin 2 L 18 32V DC N Warnung Das Ger t SCALANCE X005 ist f r den Betrieb mit Sicherheitskleinspannung ausgelegt Entsprechend d rfen an die Versorgungsanschl sse nur Sicherheitskleinspannungen SELV nach IEC950 EN60950 VDE0805 angeschlossen werden Das Netzteil f r die Versorgung des SCALANCE X005 muss NEC Class 2 entsprechen Spannungsbereich 18 32 V Strombedarf 350 mA Schlie en Sie den SCALANCE X005 niemals an Wechselspannung an Schlie en Sie den SCALANCE X005 niemals an Gleichspannungen gr er 32 V DC an 4 6 SCALANCE X005 Anzeigen Power Anzeige gr ne LED Der Zustand der Spannungseinspeisung wird ber eine gr ne LED signalisiert Bedeutung leuchtet gr n Spannungsversorgung ist angeschlossen leuchtet nicht Spannungsversorgung ist nicht angeschlossen oder 14 V Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 4 5 Produkteigenschaften 4 7 SCALANCE X005 Technische Daten Portzustandsanzeige gr n gelbe LEDs Der Zustand der Schnittstellen wird ber f nf LEDs signalisiert Bedeutung Port 1 bis 5 LED leuchtet gr n TP Link vorhanden kein Datenempfang Port 1 bis 5 LED leuchtet gelb TP Link vorhanden Daten empfangen am TP Port Port 1 bis 5 LED blinkt gelb Testphase w hrend Power on 4 7 SCALANCE X005 Technische Daten Technische Daten des SCALANCE X005 Anschl sse Anschluss von End
30. t Pin 8 NC Pin 7 NC Pin 6 TD Pin 5 NC Pin 4 NC Pin 3 TD Pin 2 RD Pin 1 RD On SCALANCE X005 the twisted pair ports are implemented as RJ 45 jacks with MDI X assignment Medium Dependent Interface Autocrossover of a network component Notice TP cords or TP XP cords with a maximum length of 10 m can be connected at the RJ 45 TP port Depending on the cable type a maximum total cable length of 100 m is permitted between two devices with the IE FC cables and IE FC RJ 45 plugs 180 Autonegotiation Autonegotiation means the automatic detection of the functionality of the port at the opposite end Using autonegotiation repeaters or DTEs can detect the functionality available at the Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A 4 3 Product Characteristics 4 4 SCALANCE X005 TP Ports port of a partner device allowing automatic configuration of different types of device With autonegotiation two components connected to a link segment can exchange parameters and set themselves to match the supported communication functionality Note Devices not supporting autonegotiation must be set to 100 Mbps half duplex or 10 Mbps half duplex Auto polarity exchange If the receive line pair is incorrectly connected RD and RD switched the polarity is automatically adapted Note The SCALANCE X005 is a plug and play device which does not require settings for commissioning MDI MDIX Autocrossover F
31. t dem Switch SCALANCE X005 in einem Industrial Ethernet Netzwerk betreiben k nnen Sie k nnen dieses Netzhandbuch beim Customer Support im Internet unter der Beitragsnummer 117220 in elektronischer Form herunterladen Leserkreis Diese Inbetriebnahmeanleitung wendet sich an Personen welche die Inbetriebnahme des Switches SCALANCE X005 in einem Netzwerk durchf hren Normen und Zulassungen Das Ger t SCALANCE X005 erf llt die Anforderungen zur CE Kennzeichnung Ausf hrliche Hinweise hierzu finden Sie im Kapitel Hinweise zur CE Kennzeichnung Industrial Ethernet SCALANCE X005 Inbetriebnahmehandbuch A2B00051528A 1 1 2 Einf hrung 2 1 Einf hrung Dieses Kapitel gibt Ihnen einen berblick ber die Funktion des unmanaged Industrial Ethernet Entry Level Switches SCALANCE X005 Was ist m glich Der Switch SCALANCE X005 ermoglicht den kosteng nstigen Aufbau von kleinen Industrial Ethernet Linien bzw Sternstrukturen mit Switching Funktionalitat Die Gerate sind f r den Einsatz im Schaltschrank ausgelegt Hinweis Der Einsatz eines SCALANCE X005 Switches in einem redundanten Ring ist nicht m glich da er die Redundanzfunktion nicht unterst tzt Hinweis Die Anforderungen nach EN61000 4 5 Surge Pr fung auf Spannungsversorgungsleitungen werden nur erf llt bei Einsatz eines Blitzductor VT AD 24V Art Nr 918 402 Hersteller DEHN SOHNE GmbH Co KG Hans Dehn Str 1 Postfach 1640 D 92306 Neumarkt Hinweis
32. ual A2B00051528A 5 1 Installation and Maintenance 5 2 Installation on a DIN Rail 5 2 Installation on a DIN Rail Installation Install the SCALANCE X005 on a 35 mm DIN rail complying with DIN EN 50022 1 Place the upper catch of the device over the top of the rail and then push in the lower part of the device against the rail until it clips into place 2 Install the electrical connecting cables Figure 5 1 SCALANCE X005 installation on a DIN rail 35 mm Uninstalling To remove SCALANCE X005 from the rail 1 First disconnect the TP cables and pull out the terminal block for the power supply 2 Use a screwdriver to release the lower rail catch of the device and pull the lower part of the device away from the rail Industrial Ethernet SCALANCE X005 5 2 Commissioning Manual A2B00051528A Installation and Maintenance 5 3 Insfallation on a Standard Rail O amp Figure 5 2 SCALANCE X005 removing from a DIN rail 35 mm 5 3 Installation on a Standard Rail Installation on a SIMATIC 87 300 Standard Rail 1 Place the upper guide at the top of the SCALANCE housing in the S7 standard rail 2 Screw the SCALANCE X005 device to the lower part of the standard rail 3 Install the electrical connecting cables Uninstalling 1 First remove all connected cables 2 Unscrew the screw fittings at the lower part of the standard rails and subsequently pull the device away from the standard rail Industrial Ethernet SCALAN
33. unction The advantage of the MDI MDIX autocrossover function is that straight through cables can be used throughout and crossover Ethernet cables are unnecessary This prevents malfunctions resulting from mismatching send and receive wires This makes installation much easier for the user The SCALANCE X005 device supports the MDI MDIX autocrossover function Notice Fixed configured ports of partner stations must be set to 100 Mbps half duplex or 10 Mbps half duplex Notice Please note that a direct connection of two ports or an unintentional connection via several switches causes an unpermissible loop which may cause network overload and network failures Industrial Ethernet SCALANCE X005 4 4 Commissioning Manual A2B00051528A Product Characteristics 4 5 SCALANCE X005 Power Supply 4 5 SCALANCE X005 Power Supply Power Supply The power supply is connected using a 2 pin plug in terminal block The power supply is connected over a high resistance with the enclosure to allow an ungrounded setup The power supply is non floating DC 24V 0 10A 005 0BA00 1AA3 Figure 4 3 Power supply Figure 4 4 Connector pinout Pin number Pinout Pin 1 M Mass Pin 2 L 18 32V DC N Warning The SCALANCE X005 device is designed for operation with safety extra low voltage This means that only safety extra low voltages SELV complying with IEC950 EN60950 VDE0805 can be connected to the power supply terminals The power suppl
34. y unit to supply SCALANCE X005 must comply with NEC Class 2 voltage range 18 32 V current requirement 350 mA Never connect SCALANCE X005 to AC voltage Never connect SCALANCE X005 to DC voltage higher than 32 V DC 4 6 SCALANCE X005 LEDs Power indicator green LED The status of the power supply is indicated by a green LED Status Meammg Power supply is connected Not lit Power supply is not connected or lt 14 V Industrial Ethernet SCALANCE X005 Commissioning Manual A2B00051528A 4 5 Product Characteristics 4 7 SCALANCE X005 Technical Specifications Port status indicator green yellow LEDs The status of the ports is indicated by five LEDs Status Meaning Port 1 to 5 LED lit green TP link exists no data reception Port 1 to 5 LED lit yellow TP link exists data received at TP port Port 1 to 5 LED flashes yellow Test phase during power on 4 SCALANCE X005 Technical Specifications Technical Specifications of SCALANCE X005 Attachment of DTEs or network components over 5xRJ 45 sockets with MDI X pinning 10 100 twisted pair Mbps half full duplex Connector for power supply 1 x 2 pin plug in terminal block Electrical Data Power supply Power supply DC 18 32V safety extra low voltage SELV Power loss at DC 24 V typ 2W W Current consumption at rated voltage typ Overvoltage protection at input PTC resetable fuse 0 5 A 60 V Permitted Cable Lengths Connection over Industrial Ethernet FC