Home

Siemens X-400 User's Manual

image

Contents

1. INV INS E IN2Z IN6 _ IN3 IN7 DM1 IN4 IN8 DM2 Power Module LEDs DI LEDs CPU LEDs Port LEDs Figure 6 27 LEDs of the digital inputs and display modes Four modes display mode A through D are available and these are displayed by two LEDs DM1 DM2 on the Switch CPU The display modes A and C are identi cal as are modes B and D Mode DM1 DM2 IN1 5 IN2 6 IN3 7 IN4 8 Meaning DMode A Digital inputs ff off DModec IN1 through IN4 on Signal at input IN1 on Signal at input IN2 on Signal at input IN3 on Signal at input IN4 Mode DM1 DM2 IN1 5 IN2 6 IN3 7 IN4 8 Meaning DMode B Digital inputs DModep of IN5 through IN8 on Signal at input INS on Signal at input IN6 on Signal at input IN7 on Signal at input IN8 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 111 Installation and Commissioning 6 8 5 LED Display Switch CPU Display Modes A through D The set display modes are indicated as follows RM RM RM RM STBY STBY STBY STBY DM1 DM1 DM1 DM1 DM2 DM2 DM2 DM2 DMode A DMode B DMode C DMode D Figure 6 28 The individual functions RM STBY and DM1 DM2 are independent of each other
2. Figure 3 7 LEDs on the Switch CPU Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 42 C79000 G8976 C 186 03 Product Description of SCALANCE X 400 Serial Port The Switch CPU of the SCALANCE X414 3E has an RS 232 port This is used for the following purposes e Firmware updates e Management with the aid of the command interpreter Command Line Inter preter CLI including setting of the IP address information Input to the command interpreter is over command lines For more detailed information refer to the SCALANCE X 400 Configuration Man ual Pin 1 Pin 2 RD Pin 3 TD Pin 4 Pin 5 SG Figure 3 8 Pin assignment Ethernet Port On the bottom panel of the SCALANCE X414 3E there is an 8 pin RJ 45 jack This Ethernet interface can be used for productive communication with other switches or end devices This is used for the following purposes e Configuration e Commissioning The SCALANCE X414 3E can be configured either locally or over a network For more detailed information refer to the SCALANCE xX 400 Configuration Man ual Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 43 Product Description of SCALANCE X 400 3 1 4 C PLUG Configuration Plug Area of Application The C PLUG is an exchangeable medium for storage of the configuration data of the modular switch
3. P4 Power Module LEDs DI LEDs CPU LEDs Port LEDs Figure 6 32 Example Monitoring of port 1 is on Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 116 C79000 G8976 C186 03 Installation and Commissioning 6 9 Replacing the C PLUG Removing the C PLUG It is only necessary to remove the C PLUG if there is a problem on the basic de vice After removing the labeling strip the upper part of the C PLUG can be care fully levered out of the slot on the Switch CPU using a slotted screwdriver until it can be gripped with your fingers and carefully removed Notice The C PLUG must only be removed or inserted when the power supply to the de vice is turned off Inserting the C PLUG in the Slot The C PLUG is on the Switch CPU below the labeling strip After removing the la beling strip the C PLUG is inserted in the receptacle with the socket connector leading The notch in the casing must be on the right The C PLUG is inserted by pressing it into the receptacle until the C PLUG is flush with the front surface of the CPU Figure 6 33 Removing the C PLUG Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 117 Installation and Commissioning 6 10 Show Location Determining the Location of a SCALANCE X 400 To identify a SCALANCE X414 3E locally and with certainty you can use the show location function on
4. Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 73 Installation and Commissioning 6 2 2 Fitting Removing the Covers Variants of the Covers There are three variants of the covers e CV490 2x1000 1 Gbps electrical transmission 2 port displays possible slot 5 e CV490 2x100 4 blind displays no port displays connected to front possible slots 6 7 and extender module EM496 4 slots 12 through 15 e CV490 4x100 10 100 Mbps electrical transmission 4 port displays possible slots 9 through 11 and extender module EM495 8 slots 12 13 Fitting a Cover To fit a cover you do not require any tools 1 Place the two lower guides of the cover into the recesses at the lower edge of the basic device It should no longer be possible to move the cover to the side 2 Tilt the cover at an angle towards the back until the two plastic pins at the back top edge of the cover jut into the recesses in the basic device 3 Press the upper part of the cover onto the basic device until the fluted middle section of the cover is heard to click into place 4 Secure the labeling strip on the front of the cover Removing a Cover To remove a cover you do not require any tools 1 Press on the fluted middle section of the top of the cover next to the backplane 2 Atthe same time tilt the cover down at an angle the two guides initially remain in the recesses at the lower edge of the basic device 3 R
5. Figure 6 24 Display of the four possible display modes Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 108 C79000 G8976 C186 03 Installation and Commissioning 6 8 3 LED Display Power Module Display Modes A through C In display modes A through C the two LEDs DM1 and DM2 of the Switch CPU are lit as described in section 6 8 2 In these three states the status of the signaling contact and the presence of the supply voltages are displayed by the LEDs of the power module F L1 L2 DM1 DM2 Power Module LEDs DI LEDs CPU LEDs Port LEDs Figure 6 25 Example of the LED display of the power module and the Switch CPU in DMode A The following table lists the significance of the three LEDs on the power module for display modes A through C Label Color Status Meaning F off The SCALANCE X414 3E has not detected any faults the signaling contact is closed Red on The SCALANCE X414 3E has detected a fault the signaling contact opens L1 off Power supply L1 lower than 17 V Green on Power supply L1 higher than 17 V L2 off Power supply L2 lower than 17 V Green on Power supply L2 higher than 17 V Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 109 Installation and Commissioning Display in Display Mode D In display mode D both the DM
6. HSR High Speed Redundancy check the RM DIL switch before closing the ring cable If the SCALANCE X 400 adopts the function of a redundancy manager the switch must be set to ON If the SCALANCE X 400 is not being used as a redundancy manager the switch must be set to OFF Notice When using a SCALANCE X 400 in redundancy manager mode RM ON check whether the DIL switches R1 and R2 select the required ring ports before closing the ring If ports other than those set are connected to the ring they cause a ring short circuit and overload the network Notice When supplied the DIL switches R1 and R2 are set to OFF This means that the gi gabit ports on slot 5 are defined as ring ports and ring redundancy is activated In this case you cannot activate rapid spanning tree spanning tree Notice If a device is replaced remember the following points relating to a SCALANCE X 400 switch e Make the same settings on the DIL switches as they were on the old device e Make sure that you use a media module and extender configuration that is iden tical to that of the old device e Use the C PLUG of the old device in the new one so that your device configura tion is adopted Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 3 Personnel Qualification Requirements Only qualified personnel should be allowed to install and work on this equipment Qualified personnel as referred to in this man
7. The LED displays are described below Display of the possible display modes DMode A through DMode D Label Color Status Meaning RM off The SCALANCE X414 3E is not operating in redundancy manager mode Green on The SCALANCE X414 3E is operating in redundancy manager mode The ring is working without problems monitoring is activated flashes The SCALANCE X414 3E is operating in redundancy manager mode An interruption has been detected on the ring the SCALANCE X414 3E has switched through STBY off No function reserved for future applica tions DM1 Green on Display of the display mode DM2 Green on Display of the display mode 112 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 Installation and Commissioning 6 8 6 LED Display of the Ports DMode A through DMode D The two LEDs of slot 5 or the four LEDs of slots 9 through 11 of the basic device indicate various port statuses depending on the set display modes The displays have the same significance for all ports on all slots of the basic device and the ex tender modules EM495 8 and EM496 4 Port Statuses in DMode A In display mode A the current port status is displayed Port Color Status Meaning P1 off No valid link to the port for ex P2 ample station turned off or cable P3 not connected P4 Green on Link exists
8. The user then has the same options as when directly connected to this device with a terminal TP Port Port with a TP connector RJ 45 jack VLAN Virtual LAN within a physically existing network Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 143 Glossary Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 144 C79000 G8976 C186 03 Index A Accepted status cccccccccecceeeeeeeeeeeees Autonegotiation cccccececeeeceeseeeeeeeees B Basic device ie ies cciccieectersaieticnceienrivaesed Cc Cabling oeceeccesseesscesssesseesstesseeseesseesstesseeaee Collision domain ccccceceecetseeesteeeeseees Components of the product 2 2 Components of the SCALANCE X PANOT O EA e E TT D Display modes seeessessesrrrseennanrennneneena 108 E Ethernet port cccccceeeseceeeeeeeeeeeeees Extender module c ccscscceeeeeeeneeeees 61 Media module extender Twisted pair extender 00008 F Factory defaults ceeeeeeeeeteeeeees Fast Ethernet media module MM491 Fault Mask cccccseceseescsceeseessseeeserees G Gigabit media module MM492 2 Gigabit media module MM492 2LD l Industrial Ethernet ccesceeceeeeeeeeee Installation 0 cccccceeceeececeseeseeeeeettreeeeenees L LED display aeeeiwniadeinineetencdn Dim d lg eircrnr i
9. X1 ecceececeee scenes ee eeneeeeeenaeeeeeenaeeeseeiaeeeeetneeeeneaes 6 6 4 Digital Input Connectors X2 s s esssssssrrssessrnansannantennnnnannanttnnaanannnnaeennaanannaaeennaa 6 6 5 Connectors for the Twisted Pair Cables eccceeeceeeeeeeeeeeeeeeeteeeeeeetaneeeeeaes 6 6 6 Connectors for Fiber Optic Cables ccccccccsssesccssecesesesesesescrsscenersetstaeananees 99 6 7 Operator O10 8 0 cee 6 71 DIL SWRCNOS ecto ientses Air erties ee aie on ae ee dae Bl tel 6 7 2 SELECT SET Button oo ceccccecececececeeeeeeeeeeeeaeeeeeeeeeeaeeeseaeeeneeeseeeeseaeeseeeees 6 8 LED DISPlay e aleve niavea aiid 6 8 1 Startup Behavior of the SCALANCE X414 3E 000 022 ceecececcecceceeeeeeeeeeeteeeeeeeeees 6 8 2 Selecting the Display Modes eessunssrreseernnnnrsnnnnsennannnnnaneennaanannantennnannannaaeena 6 8 3 LED Display Power Module esssesssrnsseerrenssnnnnsennannsnnaneennnaanannannennaanannaaeenn 6 8 4 LED Display DI Module 0 ccc i eken AREER AEAT EA 6 38 5 LED Display Switeh CPU isis ccc este a AAAA 6 8 6 LED Display of the Ports DMode A through DMode D 6 9 Replacing the C PLUG occcrinracneritnii dini aa EEEO 610 SNOW LOCIUON Zea vectego dase coh aiid peste cnduce dah duseeg nibs cavesteceradieed csesieg eveetee eeeoia 7 Technical SPCCitiCatlons icccicccsciscssnsaacasscexnaicnscnatensecneadeannnnnensiginanannandaneedatnasanennnnaestizen 119 7 1 SCALANCE X414 3 E noiis a dead padi 119 7 2 M
10. flashes three times per Port turned off by management low period flashes four times per pe Port is monitored port riod Yel flashes lit Receiving data at port DM2 P1 P2 P3 P4 Power Module LEDs DI LEDs CPU LEDs Port LEDs Figure 6 29 Display of the port status of port 1 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 113 Installation and Commissioning Port Statuses in DMode B 114 In display mode B the current transmission rate is displayed Port Color Status Meaning P1 off Port operating at 10 Mbps P2 P3 P4 Green on Port operating at 100 Mbps Yel on Port operating at 1000 Mbps low P1 P2 P3 P4 Power Module LEDs DI LEDs CPU LEDs Port LEDs Figure 6 30 Display of the transmission rate of port 1 Note If there is a link fault and the type of transmission is fixed autonegotiation off in DMode B the desired status in other words the set transmission rate 1000 Mbps 100 Mbps 10 Mbps continues to be displayed If there is a link fault and autone gotiation is active the port LED goes off Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 Port Statuses in DMode C In
11. switches allow extremely large networks with spans of 150 km to be set up and when using LD modules even up to 1300 km Containing Load By filtering the data traffic based on the Ethernet MAC addresses local data traffic remains local In contrast to repeaters or hubs which distribute data unfil tered to all ports network nodes switches operate selectively Only data in tended for nodes in other subnets is switched from the input port to the appro priate output port of the switch To make this possible a table assigning Ethernet MAC addresses to output ports is created by the switch in a teach in mode Limitation of Errors to the Network Segment Affected By checking the validity of a data packet on the basis of the checksum which each data packet contains the switch ensures that bad data packets are not transported further Collisions in one network segment are not passed on to other segments Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 11 Introduction to Industrial Ethernet Switches The Need for Industrial Ethernet Switches With over 80 of LANs based on Ethernet this is the most commonly used tech nology The use of switches is particularly important They allow extensive net works with large numbers of nodes to be set up increase the data throughput and simplify network expansion The modular SCALANCE X 400 Industrial Ethernet switches from SIMATIC NET are desi
12. 00 The languages of the SIMATIC Hotlines and the authorization hotline are generally German and English A amp D Technical Support Service amp Support on the Internet In addition to our documentation we offer our Know how online on the internet at http Awww siemens com automation service amp support where you will find the following e The newsletter which constantly provides you with up to date information on your products e Exactly the right documents for your needs which you can access by performing an online search in Service amp Support e A forum in which users and experts worldwide exchange ideas and experiences e Information about local service repair and replacement parts Much more information can be found under Services You will find your local contact for Automation amp Drives in our partners database at http www automation siemens com partner A amp D Technical Support
13. 3E is not a redundancy manager ON SCALANCE X414 3E is a redundancy manager STBY OFF No function reserved for future applications ON R1 OFF eea rer ace eT Ports in slot 5 gigabit ports are ring ports perp Ran Ports 1 and 2 of slot 6 are ring ports R2 OFF R1 OFF Port 1 of slot 6 is first ring port R ToN E Port 1 of slot 7 is second ring port R1 ON SS ese No ring redundancy When shipped the factory settings apply see section 6 5 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 102 C79000 G8976 C186 03 Installation and Commissioning Ring Ports in Slots 5 to 7 If R1 and R2 are set to OFF the two gigabit ports of slot 5 are selected as ring ports Note If the SCALANCE X414 3E is operated without media modules R1 and R2 must be set to OFF otherwise ports in slots 6 and 7 will be defined as ring ports that are only available when media modules are plugged in Figure 6 21 Ring ports that can be defined with switches R1 and R2 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 103 Installation and Commissioning Possible Settings of the Ring Ports Note Only two ports of a switch can ever be defined as ring ports All other ports in slots 6 and 7 that are not defined as ring ports can be used for the optical connection of nodes or subnets e Switch 1 In the schemati
14. C186 03 31 System Description of SCALANCE xX 400 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 32 C79000 G8976 C186 03 Product Description of SCALANCE X 400 3 3 1 SCALANCE X414 3E Basic Device Overview The SCALANCE X 400 product line consists of modular Industrial Ethernet switches media modules and extenders 100 Mbit and 1000 Mbit technology is supported for different transmission media twisted pair fiber optic and increased port requirements The main areas of application are high performance plant net works Due to its modular structure the X 400 product line is designed to meet fu ture demands and can be adapted to meet the requirements of a particular task The SCALANCE X414 3E switch has two integrated gigabit Ethernet twisted pair ports 100 or 1000 Mbps to interconnect multiple switches The nodes are con nected over 12 fast Ethernet ports integrated in the switch 10 or 100 Mbps The integrated redundancy manager allows fast medium redundancy both for gi gabit Ethernet and for fast Ethernet even in large networks To set up optical gigabit networks both integrated gigabit Ethernet ports can be converted to fiber optic cable over a 2 port gigabit Ethernet module Module vari ants for multimode up to 750 m and single mode up to 10 km are available Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 33 Product Description of SCALANCE X 400
15. Industrial Ethernet Switches 12 C79000 G8976 C186 03 Introduction to Industrial Ethernet Switches 1 2 Topologies 1 2 1 Ring with Redundancy Manager To increase the availability optical or electrical line topologies of up to 50 switches SCALANCE X 400 SCALANCE X 200 or OSM ESM can be closed with a SCALANCE X414 3E to form a ring Functional Description With a SCALANCE X414 3E operating as a redundancy manager the two ends are closed to form a ring with redundancy manager The redundancy function is activated or deactivated by switches on the Switch CPU In contrast to the ring ports of the other switches the ring ports of the redundancy manager are disconnected when the network is operating problem free The SCALANCE X414 3E working in redundancy manager mode monitors the con nected line over its ring ports and connects the ring ports if there is an interruption on the connected line in other words it restores a functioning line over this substi tute path Reconfiguration is achieved within 0 3 s As soon as the problem is eliminated the original topology is restored in other words the ring ports in the re dundancy manager are disconnected from each other again In a ring with redundancy manager there can only be one switch configured as a redundancy manager Connection of Other Network Segments or End Devices At all ports of slots 9 to 11 or at the ports of a twisted pair extender module of the SCALANCE X414 3E as w
16. SIEMENS Figure 3 1 Basic device without media modules protective caps and covers SIEMENS Figure 3 2 Basic device with media modules and covers Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 34 C79000 G8976 C186 03 Product Description of SCALANCE X 400 Components of the Product The following components are supplied with the SCALANCE X414 3E e Basic device with power module in slot 2 DI module with eight digital inputs in slot 3 Switch CPU including C PLUG in slot 4 Protective caps for media module terminal strips in slots 5 6 and 7 e 1 CV490 2x1000 cover of media module slot 5 2 CV490 2x100 cover of media module slots 6 and 7 1 CV490 Cover dummy cover for slot 8 3 CV490 4x100 cover for slots 9 to 11 e SIMATIC NET Manual Collection CD e Slot labels for slots 1 through 18 e 1 connector for power supply 4 pin e 1 connector for signaling contact 4 pin e 2 connectors for digital inputs 5 pin e 1 sheet with 15 labeling strips Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 35 Product Description of SCALANCE X 400 Spares e 1 C PLUG order number 6GK1 900 OAB00 e 7 covers for slots order number 6GK5 490 OAA00 0AA2 1 cover for slot 5 1 Gbps TP 2 covers for slots 6 and 7 1 dummy cover for slot 8 3 covers for slots 9 to 11 100 Mbps TP e Terminal set order number 6GK5 498 1AA00 0AA0 10 connecting terminals for P
17. a programming device to select the node over the net work and make it flash This can be used for example when assigning addresses to make sure that the correct node receives the address All port LEDs of the ad dressed node flash green at 2 Hz With the PST Tool V3 0 you can trigger this function with Module Ring For more detailed information refer to the Configuration Manual SCALANCE X 400 chapter Working with the Primary Setup Tool section Deter mining the location of a device Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 118 C79000 G8976 C186 03 Technical Specifications F 7 1 SCALANCE X414 3E Interfaces ee Connecting end devices or network 2 x RJ 45 jack 10 100 1000 Mbps segments over twisted pair 12 x RJ 45 jack 10 100 Mbps All electrical ports support autonegotia tion and autocrossover Installation of media modules 2 x slot 6 and 7 for media module types MM491 2 and MM491 2LD 1 x slot 5 for media module types MM492 2 and MM492 2LD Installation of extender modules 1 x slot for extender module EM495 8 or EM496 4 Connector for power supply and signal 2 x 4 pin plug in terminal blocks ing contact Connection of digital inputs 2 x 5 pin plug in terminal blocks Power supply 2 power supplies 24 V DC 20 4 to redundant inputs isolated 28 8 V safety extra low voltage SELV Power supply voltage connected over high resistance with housing not elec trically isolate
18. an extender module remove the two covers on the extender 2 Using a slotted screwdriver with a 5 5 mm wide blade open the captive screw between slots 12 and 13 in the lower part of the extender module 3 Remove the cover from slot 11 of the basic device 4 Use a slotted screwdriver with a 2 8 mm wide blade to loosen the two captive slug screws on slot 11 of the basic device in the upper and lower recesses as far as they will go 5 Push the extender module slowly to the right while keeping it straight until the two guide bolts of the extender module are completely outside the holes in the basic device 6 Pull out the lower part of the extender module slightly towards the front and lift it from the S7 300 rail 7 Replace the right side panel of the basic device so that the guide bolts fit into the two holes in the basic device 8 Using a slotted screwdriver with a 2 8 mm wide blade tighten the two captive slug screws on slot 11 The screws lock the two guide bolts so do not use ex cessive force when tightening them 9 Fit a suitable cover on slot 11 of the basic device Note The basic device must not be used permanently without the right side panel 78 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 Installation and Commissioning Installing the Twisted Pair Extender on the 35 mm Standard Rail AN Caution If the SCALANCE X 400 with extender is liable to severe vibration
19. and Commissioning Figure 6 1 Installation on an S7 300 rail Removing from the S7 300 rail To remove the device you require a slotted screwdriver with a 5 5 mm wide blade Notice When removing the SCALANCE X414 3E hold it by the backplane and not by the modules otherwise the device may be damaged To remove the device follow the steps below 1 Remove the covers from slots 7 and 9 see section 6 2 2 and the dummy cover from slot 8 see section 6 2 3 If media modules are inserted remove the fast Ethernet media module instead of the cover from slot 7 See section 6 2 1 2 Using a screwdriver with a 5 5 mm wide blade loosen the two captive screws in the backplane at slot 7 and between slots 8 and 9 3 Pull out the lower part of the basic device slightly towards the front and lift it from the S7 300 rail Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 69 Installation and Commissioning 6 1 2 Installing Uninstalling with a 35 mm Standard Rail Installation on a 35 mm Standard Rail AN 70 Caution If the SCALANCE X 400 is liable to severe vibration gt 10 g use the S7 300 rail for installation The 35 mm standard rail does not provide adequate support for the SCALANCE X 400 with vibration greater than 10 g Since the two captive screws in slot 7 and between slots 8 and 9 are not used to secure the device when installing on a 35 mm standard rail it is
20. and ships with the product This means that the configuration data remains available if the basic device is replaced Notice The C PLUG must only be removed or inserted when the power supply to the de vice is turned off How It Works Power is supplied by the basic device The C PLUG retains all data permanently when the power is turned off If an empty C PLUG factory settings or deleted with the Clean function is in serted all the configuration data of the SCALANCE X414 3E is saved to it auto matically when the device starts up Changes to the configuration during operation are saved on the C PLUG without operator intervention if this is in the ACCEPTED status Figure 3 9 C PLUG Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 44 C79000 G8976 C186 03 Product Description of SCALANCE X 400 A device with an accepted C PLUG ACCEPTED status inserted uses the configu ration data of the C PLUG automatically when it starts up Acceptance is possible only when the data was written by a compatible device type This allows a basic device to be replaced quickly and simply The C PLUG is taken from the failed component and inserted in the replacement The first time it is started up the replacement device has the same configuration as the failed device except for the MAC address set by the vendor Notice If the SCALANCE X414 3E is replaced the settings of the DIL switches on the Switch CPU and the con
21. data transmission at a data transmission rate of 100 Mbps over multimode or single mode FOC Figure 4 1 Slots for the media modules Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 50 C79000 G8976 C186 03 Media Modules Covers Dummy Cover 4 1 1 Fast Ethernet Media Module MM491 2 100Base FX The fast Ethernet media module MM491 2 can be used optionally in slots 6 and 7 of the basic device and when using the media module extender EM496 4 it can also be used in slots 12 through 15 Mixed operation with the fast Ethernet media module MM491 2LD is possible Properties The fast Ethernet media module provides two ports for connecting the multimode FOC The signal is transmitted by LED with a wavelength of 1310 nm The maxi mum cable length is 3 km Connector The connectors are 2x2 BFOC sockets LED Display of the Fast Ethernet Media Module The LED displays of the module are the same as the LEDs of the basic device With optical transmission a fixed transmission rate of 100 Mbps and full duplex mode is set The display in display modes B and C is analogous e In display mode A the current connection status is displayed e In display mode B the fixed transmission rate is displayed e In display mode C the full duplex mode is displayed e In display mode D you can see whether or not the port is monitored F
22. 0 10 km 10 125 um single mode fiber 0 5 dB km at 1310 nm 6 dB max per mitted FO cable attenuation at 3 dB link power margin Environmental Conditions TENG SSS construction iS Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 126 C79000 G8976 C186 03 Technical Specifications 7 6 Extender Module EM495 8 Connecting end devices or network 8 x RJ 45 jacks 10 100 Mbps segments over twisted pair All electrical ports support autonegotia tion and autocrossover TP cable length With TP cord up to 10 m with FastConnect cabling system up to 100 m Permitted Environmental Conditions EMC construction SSCS Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 127 Technical Specifications Figure 7 2 Dimension drawing extender module EM495 8 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 128 C79000 G8976 C186 03 Technical Specifications 7 7 Extender Module EM496 4 Installation of media modules 4 x slots for media module MM491 2 MM491 2LD Power consumption without media lt 0 5W modules Permitted Environmental Conditions EMC Storage transport temperature 40 C through 80 C Construction Dimensions W x H x D 154 x 145 x 112
23. 0 0 eee eee e tte ee eee ne ee erent ee erent ee eetaaeee ee eaaeeeeenaeeeseeeaeeeeeeaes SAIS OWEN CPU eiria aAa EA A a A Aa eaa AAA AAAA tore 3 1 4 C PLUG Configuration Plug eeesseeessseeeresssrrsserrsseirrsstrrnseeenrnstnrnsennssreennt Sko PONS e r E a a e a ia desee cotaa cee 4 Media Modules Covers Dummy COVED eceeeeeeeeeeeeneeeeeeeenseessaneeseeeenseesenanee 4 1 Media MOduless mecsre a a aiii 4 1 1 Fast Ethernet Media Module MM491 2 100Base FX eeeeeeeeetereeeeneeeees 4 1 2 Fast Ethernet Media Module MM491 2LD 100Base FX 0 ceeeeteeeeeees 4 1 3 Gigabit Media Module MM492 2 1000BasSe SX 0 0 cece ceeeeeceeeeeeeteeeenteeeees 4 1 4 Gigabit Media Module MM492 2LD 1000Base LX ccceeeeeeteteeeeteteeees 4 2 Covers DUMMY COVED ccccceeeeecceceeceeeeeeeesecceaeeeeeseeesececaeceeeeeeeesetensinaeeeeeess GZ IAW COVES E duran cantante E E E A ma ciesers 4 2 2 Dummy COVED o oo eee cceeeee eee ceee eter eeeeeeeeceneeeeeceeeeeeseaeeeeeeeeeaeeeseeeaeeeseeaeeeeeeeaeees 5 Extender MOdulles ccccccccscsssssseeeeeceeeccensseneeeeeeeenseeseeeeeeenansesseeseseeeecsassenseseseenanseneees 5 1 Twisted Pair Extender EM495 8 o oo ceesceccceceeeceeeseeeeeeeeeeaneeseeeeeeseaneasneeees 5 2 Media Module Extender EM496 4 ccccccccsseseececeeeeeseeeeeeeeeeeaeeaseseeeeneeseanees 6 Installation ANd COMMISSIONING eccseseeeceeeeeeeeneeeeeeseseeneeseseeeeesneneenen
24. 00 G8976 C186 03 Media Modules Covers Dummy Cover 4 1 3 Gigabit Media Module MM492 2 1000Base SX The MM492 2 gigabit media module can be inserted as an option in slot 5 Properties The gigabit media module provides two ports for connecting the multimode FOC The signal is transmitted using an LED at a wavelength of 850 nm Both ports of the module can be configured as ring ports The maximum cable length is 750 m when using SIMATIC NET fiber optic cables Connector SC duplex female connectors are used LED Display of the Gigabit Media Module The LED displays of the module are the same as the LEDs of the basic device With optical transmission only a fixed transmission rate and full duplex mode are possible The display in display modes B and C is analogous e In display mode A the current connection status is displayed e In display mode B the fixed transmission rate is displayed e In display mode C the full duplex mode is always displayed e In display mode D you can see whether or not the port is monitored Figure 4 4 Slot of the MM492 2 media module Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 53 Media Modules Covers Dummy Cover 4 1 4 Gigabit Media Module MM492 2LD 1000Base LX The MM492 2LD gigabit media module can be inserted as an option in slot 5 Properties The media module provides two ports for conne
25. 1 and DM2 LEDs of the Switch CPU are on This mode indicates whether the power supply is being monitored with the signaling contact XN 3 ARENA REN Power Module LEDs DI LEDs CPU LEDs Port LEDs Figure 6 26 LED display of the power module and the Switch CPU in DMode D The following table shows the meaning of the three light emitting diodes on the power module in display mode D Label Color Status Meaning F off No problem has been detected by the SCALANCE X414 3E Red on The SCALANCE X414 3E has detected a problem The signaling contact opens L1 off Power supply L1 is not monitored If L1 falls below 17 V the signaling contact does not respond Green on Power supply L1 is monitored If L1 falls below 17 V the signaling contact responds L2 off Power supply L2 is not monitored If L2 falls below 17 V the signaling contact does not respond Green on Power supply L2 is monitored If L2 falls below 17 V the signaling contact responds Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 110 C79000 G8976 C186 03 Installation and Commissioning 6 8 4 LED Display DI Module LED Display of the Digital Inputs 1 through 8 The status of four digital inputs IN1 through IN4 or IN5 through IN8 can be indi cated by the four LEDs on the front panel of the DI module
26. 4 mm Weight 980 g Degree of protection IP 20 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 129 Technical Specifications Figure 7 3 Dimension drawing extender module EM496 4 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 130 C79000 G8976 C186 03 Approvals Certificates Note The specified approvals apply only when the corresponding mark is printed on the product You can check which of the following approvals have been granted for your product by the markings on the type plate CE Marking SIMATIC NET SCALANCE X 400 Industrial Ethernet switches meet the require ments and aims of the following EU directives and comply with the harmonized European standards EN for programmable logic controllers published in the Offi cial Journal of the European Communities e Directive 89 336 EEC Electromagnetic Compatibility EMC Directive e Directive 73 23 EEC Electrical Equipment Designed for Use within Certain Voltage Limits Low Voltage Equipment Directive e Directive 94 9 EEC Equipment and Protective Systems intended for Use in Po tentially Explosive Atmospheres Explosion Protection Directive The EU declarations of conformity are available for th
27. 45 plug to the left with a small screwdriver 2 Remove the cable Figure 6 17 Releasing the FastConnect RJ 45 plug Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 98 C79000 G8976 C186 03 Installation and Commissioning 6 6 6 Connectors for Fiber Optic Cables Gigabit Transmission with FOC Data transmission at 1 Gbps is over multimode FOC or single mode FOC In both cases the fiber optic cable is plugged into the SC duplex socket with the SC du plex plug The connectors have polarity reversal protection mechanisms When a media module is inserted port 1 is to the front and port 2 to the rear Notice Fiber optic cable connectors are susceptible to contamination and mechanical damage to the face Protect open connections with the supplied dust caps Figure 6 18 SC Duplex plug with gigabit media module MM492 2LD Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 99 Installation and Commissioning Fast Ethernet Transfer with FOC Data transmission at 100 Mbps is over multimode FOC or single mode FOC In both cases the BFOC plug on the fiber optic cable is plugged into the BFOC socket When a media module is inserted the two front sockets belong to port 1 and the two rear sockets to port 2 The front socket is the input and the rear socket is the output socket of the particular port Behind the labeling strip on the front of the me dia module you will
28. G8976 C186 03 95 Installation and Commissioning With the IE FC RJ 45 modular outlet insert 2FE the eight wire FastConnect cable is split over two RJ 45 jacks and allows a transmission rate of 2 x 100 Mbps Figure 6 15 IE FC RJ 45 Modular Outlet Insert 2FE Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 96 C79000 G8976 C186 03 Installation and Commissioning The maximum segment length of 100 m also applies when using the FastConnect cabling with TP cord Normally FastConnect cable with a length of 90 m is used The remaining 10 m is then available for TP cord at both ends total of 10 m IE FC RJ45 IE FC RJ45 Modular Modular Outlet Insert aa Outlet Insert 1GE 2FE IE FC RJ45 Modular Outlet Insert 2FE ana A2 IE FC RJ45 Modular Outlet Insert 1GE A1 A2 10m A1 B A2 100m Figure 6 16 FastConnect Cabling A1 TP Cord 4x2 A2 TP Cord 4x2 B IE FC Standard Cable 4x2 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 97 Installation and Commissioning Removing the FC Cable from SCALANCE X414 3E Under some circumstances a screwdriver is necessary to remove the twisted pair cables with RJ 45 plugs because it may not be possible to reach the connector with your hand due to neighboring media modules covers or the dummy cover If this is the situation do the following 1 Press the catch on the RJ
29. IL switch settings of the C PLUG and not the physical switch settings are adopted A deviation is signaled by the diagnostic op tions For more detailed information refer to the SCALANCE X 400 Configuration Man ual Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 46 C79000 G8976 C186 03 Product Description of SCALANCE xX 400 3 1 5 Ports The SCALANCE X414 3E basic device provides two gigabit ports on slot 5 and four fast Ethernet ports on each of slots 9 through 11 The two ports on slot 5 can be used as ring ports IN1 IN5 IN2 IN6 IN3 IN7 IN4 IN8 Figure 3 10 Ports on the basic device Figure 3 11 Basic device with gigabit fiber optic cable fast Ethernet fiber optic cable and fast Ethernet twisted pair cable Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 47 Product Description of SCALANCE xX 400 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 48 C79000 G8976 C186 03 Media Modules Covers Dummy Cover 4 1 Available Module Types The following media modules are available to expand the basic device Media Modules MM491 2 100 Mbps order number 6GK5 491 2AB00 8AA2 MM491 2LD 100 Mbps order number 6GK5 491 2AC00 8AA2 MM492 2 1000 Mbps order number 6GK5 492 2AL00 8AA2 MM492 2LD 1000 Mbps order number 6GK5 492 2AM00 8AA2 4 By using media modules you can increase the nu
30. Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 57 Media Modules Covers Dummy Cover CV490 4x100 The SCALANCE X414 3E provides you with four electrical fast Ethernet ports on slots 9 through 11 Figure 4 10 Slots 9 through 11 for cover CV490 4x100 Displays of the Cover The status of each of the four fast Ethernet ports 1 through 4 is displayed on the front panel of the CV490 4x100 cover by four LEDs Further Slots for the CV490 4x100 Cover The CV490 4x100 cover can not only be used with the SCALANCE X414 3E but also for slots 12 and 13 of the twisted pair extender EM495 8 Figure 4 11 Slots 12 and 13 for the CV490 4x100 cover on the twisted pair extender module EM495 8 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 58 C79000 G8976 C186 03 Media Modules Covers Dummy Cover 4 2 2 Dummy Cover Slot of the Dummy Cover The dummy cover with the name CV490 COVER is located in slot 8 of the SCALANCE X414 3E Due to system requirements this slot has no function Figure 4 12 Slot 8 of the dummy cover Displays of the Dummy Cover The LEDs of the dummy cover have no function and there is therefore no port in formation on the front panel of the dummy cover Operating Instructions for SCALANCE X 400 Industrial Ethern
31. POMS iin aia Power MOdUIE cccccccesecsseeeeeeees 109 Switch CPU teddies ttatalenn M Media modules Monitored port ccccececeeeseeeeeeeeees 113 O Operator Controls ccceeteeeeeees DIL SWitCheS isnin na n SELECT SET button Order NUMbEIS cccceteeeeeeeeseeeeees P Port status DMode A u ecsesscssessessessesssseesesseeeeesees DMode B nn DMode C on csassavacecvasnatininanrntseinsnneneacs DM d Dirasani Ports Data Cable c ecccceeeeeeeeeetteeeeees Digital inputs Power SUDDI Y 0 cccceceeeeeeeeetreeeees Signaling contact esenee Ports of the SCALANCE X 400 Ports of the SCALANCE X414 3E Power MOdUIE cscssceseeceseeeereeeeees 39 R Range Segment length ceeeeeeeeeeee Transmission range Rapid spanning tree eneee Reconfiguration time Redundancy manager RING PoS ressa in Rings Electrical WinG isis secis2titteeticetie Givin Optical rng wsecseiteecre tists S Serial Port cececscececceceeeeeeeeneneeeeeeees Signaling contact a e O re a ectediaaadsteietedeete Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 145 Index Standby function Transmission mode Status as shipped Full CUpIOX 000 0 ceeeeeeeeeeeeeeeeeeeteeeeeee MOWILCIMIING 2525 fetes deuce bs eed he eietedecneda deeeseees Half GUpIOX 000 eee
32. S and signaling contact 4 pin 10 connecting terminals digital inputs 5 pin e 1 location label order number 6ES7 912 OAA00 0AA0 e 10 sheets of labels A4 each with 15 labeling strips order number 6GK5 498 0AA00 0AA0 Slots The SCALANCE X414 3E basic device consists of a backplane with three perma nently installed modules in slots 2 3 and 4 Switch CPU 3 i z O a Digital Inputs 10 100 1000 MBit s Twisted Pair 10 100 MBit s Twisted Pair 10 100 MBit s Twisted Pair 10 100 MBit s 4 x RJ45 2 x RJ45 4 x RJ45 Twisted Pair 4 x RJ45 Figure 3 3 Basic device without media modules with existing ports Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 36 C79000 G8976 C186 03 Product Description of SCALANCE X 400 The modules in the individual slots have the following function slot 1 is reserved for a power supply unit e Slot 2 Power module The input voltage of 24 V DC is transformed to the internal supply voltage The module has two 4 pin sockets for connecting a redundant power supply and for connecting the signaling contact and protective earth e Slot 3 Digital input module The input module has two 5 pin sockets for connecting eight digital inputs that allow different signaling modes e Slot 4 CPU module Contains the processor that provides the management functionality C PLUG for storage of parameter assignment DlL switch for the redundancy man
33. SIEMENS SIMATIC NET Preface Contents Operating Instructions for dace cinsiaek Switches SCALANCE X 400 Industrial Ethernet Switches System Description of 2 SCALANCE X 400 Product Description of 3 SCALANCE X 400 Media Modules Covers Dummy Cover Extender Modules Installation and 6 Commissioning Technical Specifications Approvals Certificates i Glossary Index C79000 G8976 C186 03 Release 11 2005 Classification of Safety Related Notices This document contains notices which you should observe to ensure your own per sonal safety as well as to protect the product and connected equipment These no tices are highlighted in the manual by a warning triangle and are marked as follows according to the level of danger Danger indicates that death or severe personal injury will result if proper precautions are not taken Warning indicates that death or severe personal injury can result if proper precautions are not taken Caution with warning triangle indicates that minor personal injury can result if proper precau tions are not taken Caution without warning triangle indicates that damage to property can result if proper precau tions are not taken Notice indicates that an undesirable result or status can occur if the relevant notice is ig nored Note highlights important information on the product using the product or part of the docu mentation that is of partic
34. adding the media module extender the basic device is extended by four slots that you can equip with the following modules as required e MM491 2 e MM491 2LD If you use all slots you have an additional eight optical fast Ethernet ports available 100 Mbps Note Installation of the media module extender and removal or insertion of the media modules is possible during operation You require at least one media module for data transfer over this extender module Mixed operation in slots 12 through 15 with MM491 2 and MM491 2LD modules is possible The media module plug connectors are protected by protective caps Connector The connectors are 2x2 BFOC sockets Figure 5 3 Basic device with media module extender Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 63 Extender Modules a a Figure 5 4 Empty media module extender EM496 4 without protective caps for the media module plug connectors and without cover Covers Four CV490 2x100 covers are supplied with the media module extender EM496 4 The media module plug connectors are also protected from damage by protective caps Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 64 C79000 G8976 C186 03 Extender Modules Figure 5 5 Media module extender EM496 4 with media module MM491 2 in slot 12 and with cover Operating Instructions for SCALANCE X 400 Ind
35. ager function and to specify the ring ports SELECT SEL button for switching over the display modes for resetting to the factory default settings and to define the fault mask LED display of the display modes DMode A through DMode D e Slot 5 Contains two RJ 45 jacks allowing attachment of electrical twisted pair con nections 10 100 1000 Mbps As an option slot 5 allows the use of an optical gigabit module with two ports 1000Base SX or 1000Base LX e Slots 6 and 7 Optional use of two optical fast Ethernet modules 100 Mbps each with two ports 100Base FX e Slot 8 No function in system e Slot 9 through 11 Each contains four RJ 45 jacks allowing attachment of 12 electrical twisted pair connections in total 10 100 Mbps These cannot be used by media modules Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 37 Product Description of SCALANCE xX 400 The basic version of the SCALANCE X414 3E without expansion with media mod ules provides 14 ports The two ports in slot 5 can be used as ring ports Figure 3 4 Ports of the SCALANCE X414 3E By inserting media modules in slots 6 and 7 you have 4 further optical ports avail able either as ring ports or as end device ports By docking an extender module to the right of slot 11 you can extend the basic device by a further 8 ports There are two types o
36. and not by the modules otherwise the device may be damaged To remove the device follow the steps below 1 Push the basic device down until the lower part can be pulled away from the standard rail to the front 2 Lift the SCALANCE X414 3E up and off the standard rail Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 71 Installation and Commissioning 6 2 Installing Removing the Media Modules Covers and Dummy Cover 6 2 1 Installing Removing a Media Module Installing a Media Module For installation you require a slotted screwdriver with a 2 8 mm wide blade Note Installing a fast Ethernet media module is the same in the SCALANCE X414 3E and in the media module extender 1 Remove the cover see section 6 2 2 from the slot of the media module and remove the protective cap from the module terminal strip from the backplane of the basic device Note Keep these parts in a safe place in case you want to remove the media mod ule later 2 Remove the inserted labeling strip from the front of the media module 3 Place the two lower guides of the media module into the recesses at the lower edge of the basic device It should no longer be possible to move the media module to the side 4 Tilt the media module at an angle towards the back until the two plastic pins at the back top edge of the media module jut into the recesses in the basic de vice The terminal strip of th
37. ble 2x2 is necessary Transmission range The maximum transmission distance segment length is 100 m Connectors The connectors used are 8 pin RJ 45 jacks with securing collars The securing collar in conjunction with the cover ensures a flush fit and the locking mechanism with the PROFINET compliant male connector IE FC RJ 45 Plug 180 provides a rugged node attachment suitable for an industrial environment that pro vides strain and bending relief for the RJ 45 jack Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 25 System Description of SCALANCE xX 400 2 2 2 1000Base TX Transmission Rate The transmission rate of the electrical gigabit ports is 1 Gbps Transmission Mode The transmission mode for 1000Base TX is specified in the IEEE 802 3ab stan dard At 1 Gbps autonegotiation is optional Two communication modes are possible e Half duplex e Full duplex Transmission Medium Data is transmitted over an 8 wire twisted pair cable Notice For data transmission at 1 Gbps at least Cat 5e twisted pair cabling with 4x2 wires is required With a four wire cable 2x2 the maximum possible data rate is 100 Mbps Transmission Range The maximum transmission distance segment length is 100 m Connectors The connectors used are 8 pin RJ 45 jacks Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 26 C79000 G8976 C186 03 System Description o
38. c below switches R7 and R2 are set to OFF e Switch 2 In the schematic below switch R1 is set to ON and R2 is set to OFF e Switch 3 In the schematic below switch R1 is set to OFF and R2 is set to ON Switch 1 Switch 2 Switch 3 H E i p Figure 6 22 The three possible settings for ring ports with R1 and R2 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 104 C79000 G8976 C186 03 Installation and Commissioning 6 7 2 SELECT SET Button The SELECT SET button is used to switch over the display modes DMode After turning on the SCALANCE X414 3E it is in DMode A The button has the following functions e Changing the display modes By pressing the button briefly you change from one display mode to the next The selected mode or current status is displayed by the LEDs DM1 DM2 e Resetting to the factory defaults It is possible to restore some of the factory default settings in DMode A by pressing the button for 12 seconds You can cancel the reset procedure by re leasing the button before the 12 seconds have elapsed All previously made settings are overwritten by the factory defaults e Defining the fault mask and the LED displays It is possible to set the fault mask in DMode A and DMode D This allows you to specify the mask for signaling faults by defining an individual good status for the connected ports and the
39. ching In this case the IE FC standard ca ble 2x2 is connected directly to the SCALANCE X414 3E and other components on the network Two FastConnect cable types are available the eight wire IE FC standard cable 4x2 and the four wire IE FC standard cable 2x2 The diameter of the IE FC standard cable 4x2 does not allow connection to an RJ 45 plug so that only the IE FC standard cable 2x2 as a four wire cable is suitable for RJ 45 plugs This means that the maximum transmission rate is 100 Mbps The flexible eight wire patch cable TP cord for gigabit transmission allows a maxi mum cable length of 10 m Figure 6 13 FastConnect Cabling A TP cord 1 Gbps B IE FC Standard Cable 2x2 100 Mbps Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 Installation and Commissioning Connecting TP Cord to FC Cable To connect TP Cord to FC cables two IE FC RJ 45 modular outlet insert types are available e IE FC RJ 45 modular outlet insert 1GE 1 R J45 jack with 4x2 wire cable for 1 Gbps e IE FC RJ 45 modular outlet insert 2FE 2 RJ 45 jacks each with 2x2 wire cable for 100 Mbps With the IE FC RJ 45 modular outlet insert 1GE the eight wire FastConnect cable allows a transmission rate of 1 Gbps Figure 6 14 IE FC RJ 45 Modular Outlet Insert 1GE Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000
40. consisting of Backplane Power module DI module Switch CPU Two 1000BaseTX interfaces Twelve 100BaseTX interfaces Extender interface Media module fiber optic 1000 Mbps Media module 100 Mbps Twisted pair extender Media module extender The power module con verts the 24 V input power into the internal operating voltage of the basic de vice There are eight digital in puts for feeding in exter nal signals The Switch CPU man ages the data traffic The CPU also has a serial and an Ethernet port Expands the basic device by two gigabit fiber optic ports Expands the basic device by two fast Ethernet fiber optic ports Expands the basic device by eight fast Ethernet ports with RJ 45 jacks Expands the basic device by four slots for fast Ethernet media modules o o o o o o o o o 0 0 0 For example SCALANCE X414 3E om For example MM492 2 om For example MM491 2 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 23 System Description of SCALANCE xX 400 2 2 Ports of SCALANCE X 400 SCALANCE X 400 provides you with electrical ports that can be used as gigabit and ring ports The expans
41. cting the single mode FOC Signal transmission uses a laser diode at a wavelength of 1310 nm Both ports of the module can be configured as ring ports The maximum cable length is 10 km when using SIMATIC NET fiber optic cables Connector SC duplex female connectors are used LED Display of the Gigabit Media Module The LED displays of the module are the same as the LEDs of the basic device With optical transmission only a fixed transmission rate and full duplex mode are possible The display in display modes B and C is analogous e In display mode A the current connection status is displayed e In display mode B the fixed transmission rate is displayed e In display mode C the full duplex mode is always displayed e In display mode D you can see whether or not the port is monitored Figure 4 5 Slot of the MM492 2LD media module Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 54 C79000 G8976 C186 03 Media Modules Covers Dummy Cover 4 2 Covers Dummy Cover 4 2 1 Covers Slots of the Covers Note The protective caps for the media module terminal strips and the covers must be fitted in all slots that do not contain media modules For slots for twisted pair 9 through 11 the covers are recommended to protect the RJ 45 jacks Figure 4 6 Possible slots of the covers Availabl
42. d Tested to IEC 6100 4 5 1995 Surge Immunity Test performed with light ning protection device DEHN Blitzduc tor VT AD 24V article no 918 402 is used Power consumption without modules 15 W at 24 V DC Current consumption at 24 V DC lt 2000 mA Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 119 Technical Specifications Load on the signaling contact 24 V DC max 100 mA safety extra low voltage SELV Overcurrent protection at input Non replaceable fuse F 3 15 A 250 V Digital Inputs Input voltage Rated value 24 V DC safety extra low voltage SELV For state 1 13 V 30 V For state 0 30 V 3 V Max input current 8 mA Max cable length 30 m Inputs isolated from electronics eg Memory capacity 32 Mbytes TP cable length With TP cord up to 10 m with FastConnect cabling system up to 100 m Line star structure Any only depending on signal propa gation time Ring with redundancy manager 50 for reconfiguration time lt 0 3 s Switching Properties SSS Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 120 C79000 G8976 C186 03 Technical Specifications Permitted Environmental Conditions EMC Operating temperature 0 C through 60 C Storage transport temperature 40 C through 80 C Relative humidity in operation lt 95 no condensation Operating altitude Max 2000 m Noise emiss
43. d over The redundant power supply is connected over a 4 pin connector at the front ter minal block on the power module Figure 6 9 Pin assignment of connector X1 Conn 1 L1 24 V power supply 1 M1 Ground M2 Ground L2 24 V power supply 2 90 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 Installation and Commissioning 6 6 2 Connectors of the Signaling Contact and Grounding Strap X2 The signaling contact is connected by contacts MK1 and MK2 on the 4 pin connec tor to the rear terminal block on the PS module Figure 6 10 Pin assignment of connector X2 By inserting a strap between protective earth P and M3 the SCALANCE X414 3E switch can be operated with grounded reference potential When the device ships no strap is fitted non grounded reference potential Conn 2 MK1 Floating signaling contact relay connector 1 M3 Ground GND Protective earth MK2 Floating signaling contact relay connector 2 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 91 Installation and Commissioning 6 6 3 Digital Input Connectors X1 Polarity Reversal Protection X1 X2 The two 5 pin male connectors X1 X2 of the digital inputs 1 through 8 have no polarity reversal protection If the connectors are accidentally swapped over this does not cause dama
44. d screwdriver with a 2 8 mm wide blade The captive screw in the lower part of the extender module between slot 12 and 13 is not used for mounting on an 35 mm standard rail When removing a twisted pair extender from a 35 mm standard rail the basic device remains in position Follow the steps below 1 Remove the cover from slot 11 of the basic device 2 Use a slotted screwdriver with a 2 8 mm wide blade to loosen the two captive slug screws on slot 11 of the basic device in the upper and lower recesses as far as they will go 3 Push the extender module slowly to the right while keeping it straight until the two guide bolts of the extender module are completely outside the holes in the basic device 4 Push the twisted pair extender down until the lower part can be pulled away from the standard rail to the front 5 Lift the extender module up and off the 35 mm standard rail 6 Replace the right side panel of the basic device so that the guide bolts fit into the two holes in the basic device 7 Using aslotted screwdriver with a 2 8 mm wide blade tighten the two captive slug screws on slot 11 The screws lock the two guide bolts so do not use ex cessive force when tightening them 8 Fit a suitable cover on slot 11 of the basic device Note The basic device must not be used permanently without the right side panel Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 81 Installation and C
45. ditions EMC E iOS Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 123 Technical Specifications 7 3 Media Module MM491 2LD 100Base FX Connection of end devices or network 2x2 BFOC sockets segments over FOC 100 Mbps 100BaseFX full duplex Power of the laser diode Power of the laser diode the laser diode lt lt 2mWw a mW FOC lengths 0 26 km 10 125 um single mode fiber 0 5 dB km at 1310 nm 13 dB max permitted FO cable attenuation at 3 dB link power margin Permitted Environmental Conditions EMC construction sd SSCS Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 124 C79000 G8976 C186 03 Technical Specifications 7 4 Media Module MM492 2 1000Base SX Connection of end devices or network 2 x SC duplex sockets segments over FOC 1000 Mbps 1000BaseSX full duplex Power of the laser diode lt 0 675 mW FOC lengths 0 750 m 50 125 um multimode fiber 1 dB km at 1310 nm 1200 MHz km 4 5 dB max permitted FO cable at tenuation at 3 dB link power margin Environmental Conditions EMC SSS construction iS Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 125 Technical Specifications 7 5 Media Module MM492 2LD 1000Base LX Connection of end devices or network 2 x SC duplex sockets segments over FOC 1000 Mbps 1000BaseLXx full duplex FOC lengths
46. e Cover Types To cover slots not used for media modules or slots for twisted pair the following types of cover are available e CV490 2x1000 e CV490 2x100 e CV490 4x100 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 55 Media Modules Covers Dummy Cover CV490 2x1000 When using the gigabit ports for electrical cables twisted pair use cover type CV490 2x1000 on slot 5 Figure 4 7 Slot 5 for cover CV490 2x1000 Displays of the Cover The port status of the two electrical gigabit ports 1 and 2 are displayed on the front panel of the cover by two LEDs Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 56 C79000 G8976 C186 03 Media Modules Covers Dummy Cover CV490 2x100 Slots 6 and 7 are solely for the fast Ethernet media modules MM491 2 and MM491 2LD The basic device does not provide any ports on these slots Figure 4 8 Slots 6 and 7 for cover CV490 2x100 Displays of the Cover The LEDs of the CV490 2x100 cover have no function Further Slots for the CV490 2x100 Cover Use the CV490 2x100 cover not only for the SCALANCE X414 3E but also for slots 12 through 15 of the media module extender EM496 4 if no media modules are in serted Figure 4 9 Slots 12 through 15 for cover CV490 2x100 on media module extender EM496 4 Operating
47. e MM492 2 order number 6GK5 492 2AL00 8AA2 e Media module MM492 2LD order number 6GK5 492 2AM00 8AA2 e Extender module EM495 8 order number 6GK5 495 8BA00 8AA2 e Extender module EM496 4 order number 6GK5 496 4MA00 8AA2 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 7 Preface Further Documentation For help on configuration and diagnostics using Web based management the CLI command line or SNMP refer to the following documentation e SCALANCE X 400 Configuration Manual C79000 G8976 C 187 01 This documentation is available on the Internet at http support automation siemens com WW view en 19625108 e SIMATIC NET Twisted Pair and Fiber Optic Networks C79000 G8976 C 125 02 This documentation is available on the Internet at http support automation siemens com WW view en 8763736 Standards and Approvals The devices of the SCALANCE X 400 product line meet the requirements for CE marking For more detailed information refer to the appendix of these Operating Instructions Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 8 C79000 G8976 C186 03 Contents 1 Introduction to Industrial Ethernet Switches ccccccccsssssssseeeeeecesnsseneeeeseeeeeeeees 1 1 Basic INTOrMAatiOn iciicctisieicccscdecccdsssehedetscdsscvetadaadasasesacdstedacdasaseetdcedecedaddevicdsdaase 1 2 Topologies te eee 1 2 1 Ring with Redundancy Manager ccc
48. e media module must fit into the guide in the back plane 5 Press the upper part of the media module onto the basic device until the fluted middle section of the media module is heard to click into place 6 Tighten the captive screw on the front of the media module with a slotted screwdriver with a 2 8 mm wide blade 7 Secure the labeling strip on the front of the media module Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 72 C79000 G8976 C186 03 Installation and Commissioning Figure 6 3 Inserting a media module Removing a Media Module To remove the device you require a slotted screwdriver with a 2 8 mm wide blade Note Removing a fast Ethernet media module is the same in the SCALANCE X414 3E and in the media module extender 1 Remove the inserted labeling strip from the front of the media module 2 Release the captive screw on the front of the media module as far as it will go with a slotted screwdriver with a 2 8 mm wide blade 3 Press on the fluted middle section of the top of the media module next to the backplane 4 Atthe same time tilt the media module down at an angle the two guides ini tially remain in the recesses at the lower edge of the basic device 5 Remove the media module by pulling it upwards 6 Fit the protective cap on the module terminal strip on the backplane of the ba sic device Fit the appropriate cover see section 6 2 2 to the slot of the media module
49. e responsible authorities ac cording to the above mentioned EU directive at the following address Siemens Aktiengesellschaft Automation and Drives Industrial Communication SIMATIC NET Postfach 4848 D 90327 Nuernberg Germany Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 131 Approvals Certificates EMC Directive The products are designed for use in an industrial environment EN 61000 6 4 2001 EN 61000 6 2 2001 Explosion Protection Directive Complying with EN 50021 Electrical apparatus for potentially explosive atmos pheres Type of protection n II 3 G EEx nA II T3 T6 Note When using installing SIMATIC NET products in hazardous area zone 2 make absolutely sure that the associated conditions are adhered to You will find these conditions on the SIMATIC NET Manual Collection CD Required FDA and IEC labels The listed media modules meet the FDA and IEC requirements e MM491 2LD e MM492 2 e MM492 2LD Complies with 21 CFR 1040 10 and 1040 11 Figure 8 1 FDA and IEC labels FDA and IEC labels are not required for media module MM491 2 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 132 C79000 G8976 C186 03 Approvals Certificates Directive on Machines The product remains a component in compliance with Article 4 2 of the EU direc tive on machines 89 392 EEC According to the directive on machines
50. eceeeteeeeeteeeeeeteeneeees T Transmission range Topologies Transmission PAC oi aaaaa a SM ee E cp area soy Twisted pair Cable ccccceecceeeeeees Line structure 0 0 cccceeeeeeeeetteeeeeeeees Ring with redundancy manager V Star SUCUT neinei VLAN wees scarvecsssedethaatieevherset aiaiai aat Transmission medium 000cee w Multimode fiber optic cable Single mode fiber optic cable Wavelength nescrise Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 146 C79000 G8976 C186 03 A amp D Technical Support Worldwide available 24 hours a day Nuernberg Worldwide Nuernberg Technical Support 24 hours a day 365 days a year Phone 49 0 180 5050 222 Fax 49 0 180 5050 223 Internet www siemens de automation support request GMT 1 00 Europe Africa Nuernberg United States Johnson City Asia Australia Beijing Authorization Technical Support and Technical Support and Authorization Authorization Local time Mon Fri 8 00 to 17 00 Local time Mon Fri 8 00 to 17 00 Local time Mon Fri 8 00 to 17 00 Phone 49 0 180 5050 222 Phone 1 423 262 2522 Phone 86 10 64 71 99 90 Fax 49 0 180 5050 223 Fax 1 423 262 2289 Fax 86 10 64 74 74 74 Internet www siemens de E Mail simatic hotline E Mail adsupport asia automation support sea siemens com siemens com request GMT 1 00 GMT 5 00 GMT 8
51. edia Module MM491 2 100BaSe FX cceecceceeeeeseeeeeeeeeeeeeeeseeeeeneeteaes 123 7 3 Media Module MM491 2LD 100Base FX 00 sccessseeessnesessneeeseeesen 7 4 Media Module MM492 2 1000BasSe SX ccecceeeeeeeeeeeeeeeeeeeeesseeeeeneeeeaes 125 7 5 Media Module MM492 2LD 1000BaSe LX 0 ceccceeeeeteeeeeetteeeeeeneeeeeeeaaes 126 7 6 Extender Module EM495 8 0 0 eeccceeeeeeneeeeeeneeeeeeenneeeeeeeaeeeeeenaeeeeeeneeeeeenaes 127 7 7 Extender Module EM496 4 esssesssrrsseerneessnneatennannannaneennnaanannaatennaanannaaeennaana 129 Approvals Certificates srira saaa ae aA ERA aa A EA AAAA EAKAD AA REAS EERTE 131 9 GOSS ANY a enc cece cect Petter 10 IS scat E E E A E Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 10 C79000 G8976 C186 03 Introduction to 1 Industrial Ethernet Switches 1 1 Basic Information Switching With switching technology data packets are forwarded directly from the input port to the appropriate output port during data exchange based on the address informa tion Switches operate on a direct delivery basis Essentially switches have the following functions e Connection of Collision Domains Subnets Since repeaters and star couplers hubs operate at the physical level their use is restricted the span of a collision domain Switches connect collision domains Their use is therefore not restricted to the maximum span of a repeater network On the contrary
52. eeeeeeeeeeeeeeeeeeeeneeeeeeenneeeeeeneeeeetneeeeee 1 2 2 Stat Structure ce ccccccessesssccceeceseeeeseeceeeeeaeeesecseeeeeeeeseeassececeeeauensneeeeeneeananees 1 2 9 Line Structure seiors Micednehvasscciaciase sivaacadetie vndedidoseteeativescsdadiuasns iasssecnthiacnedd 1 2 4 Redundant Linking of Network Segments cccceeeeeseeeeeeeeeeeeeeeteesteeaeees 2 System Description of SCALANCE X 400 eccccecesseeeeeeeseeneeeeseenseeeseeeseeeeseenseeeseaes 2 1 Properties Functionality and Features of SCALANCE X 400 n 2 2 Ports of SCALANCE X 400 cccccccccccccececeeeceeeeeeeeeeeeeeueusueususaeauauaeaeaeaeaeanananaes 2 2 1 10Base T 100BaSE TX 00 0 0 cccccccccececeeeeeeeeeeeseeeeeeeaeaeeeeeeeeeeaeeeaeaeaeaeaeaeaeeeaeaeaes 22 2 VOQOBASC HDX aerea wekvavancothsveswetnaves cotievetueetiv eas vetusvaecedvewniatatvnucetiswaares 223 100B3s6 FX mrana a E a E mentee ev i 224 1000Ba56 S X eirinen cina an i aa aeaa aera an EE aE ianari 2205 VWOQOBASC HEX araro a a r A a E ra a E ia 2 3 Compatibility of SCALANCE X 400 cccccccccsseeeeeesseeeeessneeeesesseesessseeeesenaes 3 Product Description of SCALANCE X 400 ccccccceseeseesseeeceeeeeseeeseeneeseeeeeeeeeeeeseeeees 3 1 SCALANCE X414 3E Basic Device ccccceceseseseeeseseeeesseseeeeeeeeeeeeeeeeeeeeeees 31 17 Power MOGUIC vis liccccaccccdeeicceccaccccccaeesacseccstnncsvecdacsuecsitaucusesitarscusdsederretiganecedeeveccadd 3 1 2 Digital INDUtS 0
53. ell as at all other switches in the ring with redundancy manager further end devices or entire subnets can be attached using twisted pair cable TP cable The use of a media module extender in the redundancy manager and in all other switches in this network structure provides the option of connecting further end de vices or complete subnets with FO cable Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 13 Introduction to Industrial Ethernet Switches Electrical Ring A redundant electrical ring with redundancy manager can be set up without media modules since the basic device provides two RJ 45 jacks on slot 5 that allow con nection of electrical twisted pair connections 10 100 1000 Mbps The factory setting defines the two ports on slot 5 as ring ports Optical Ring An optical ring with redundancy manager is only possible with media modules Which slots or ports should be used depends on the selected transmission rate The ports that can be used as ring ports are located on the media modules that can be used in slots 5 6 and 7 As an alternative to optical gigabit transmission the two ports on slot 6 or the first ports of slot 6 and 7 can be configured as ring ports for an optical fast Ethernet connection e Slot5 equipped with MM492 2 or with MM492 2LD allows the ring to be operated as an optical gigabit ring with redundancy manager e Slot 6 slot 6 and 7 in each case only por
54. emove the cover by pulling it upwards Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 74 C79000 G8976 C186 03 Installation and Commissioning 6 2 3 Fitting Removing a Dummy Cover Fitting a Dummy Cover There is only one dummy cover no port displays connected to the front on slot 8 To fit a cover you do not require any tools 1 Place the two lower guides of the dummy cover into the recesses at the lower edge of the basic device It should no longer be possible to move the dummy cover to the side Tilt the dummy cover at an angle towards the back until the two plastic pins at the back top edge of the dummy cover jut into the recesses in the basic device Press the upper part of the dummy cover onto the basic device until the fluted middle section of the dummy cover is heard to click into place Secure the labeling strip on the front of the dummy cover Removing a Dummy Cover To remove a cover you do not require any tools 1 Press on the fluted middle section of the top of the dummy cover next to the backplane At the same time tilt the dummy cover down at an angle the two guides ini tially remain in the recesses at the lower edge of the basic device Remove the dummy cover by pulling it upwards Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 75 Installation and Commissioning 6 3 Installing Removing Extender Modules 6 3 1 Install
55. en used in environments corresponding to Class Division 2 see above the product must be installed in a cabinet a suitable enclosure or closed room Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 135 Approvals Certificates Warning In hazardous areas personal injury or damage to property may occur if you make or break an electrical circuit while a SCALANCE X 400 is in operation Do not connect or disconnect any live circuits unless risk of explosion can be exc luded with certainty FM Approval The product complies with the requirements of the standards e Factory Mutual Approval Standard Class Number 3611 e FM Hazardous Classified Location Electrical Equipment Non Incendive Class Division 2 Groups A B C D T4 and Non Incendive Class Zone 2 Group IIC T4 ATEX Approval The product complies with the requirements of the standard e EN50021 Warning Use under Zone 2 or Div 2 Ex protection conditions requires the installation in a housing The housing has comply with class IP 54 according to standard EN 60529 in the scope of the EU directive 94 9 Atex 100a Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 136 C79000 G8976 C186 03 Approvals Certificates Certification The products and systems listed in this document are manufactured and marketed using a quality management system complying with DIN ISO 9001 and certified b
56. ent Interface straight On an MDI port or MDI cable the receive Rx and the send Tx leads are not crossed Medium Dependent Interface crossover On an MDI X port or MDI X cable the receive Rx and the send Tx leads are crossed Management Information Base The MIB is a formal description of net work objects in the form of a tree structure that contains all the relevant information for network management in SNMP A port mirror port with its specific data traffic can be mirrored to an other port monitor port for test purposes Protocol analysis devices can be connected to the monitor port in other words the monitor port is not available for data exchange Mirroring has no effect on the mirror port Modes are discrete waves used to transmit data within a fiber optic cable With single mode fibers only one wave propagates whereas in multimode fibers several waves propagate Modes are patterns of elec tromagnetic fields in FOCs In multimode transmission the pulse is transferred using many modes waves that travel along curved paths or are reflected within the core Attenuation is mainly caused by physical absorption and dispersion as well as by mechanical bending The amount of attenuation depends among other things on the wavelength of the input light Multimode fiber optic cables have an outer diameter of 125 um and 50 or 62 5 um core diameter Due to the larger core diameter the pulse edges de grade more than in si
57. et Switches C79000 G8976 C186 03 59 Media Modules Covers Dummy Cover Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 60 C79000 G8976 C186 03 Extender Modules 5 5 1 Twisted Pair Extender EM495 8 Eight Additional 100Base TX Ports The extender module for twisted pair transmission provides an additional eight ports for connecting twisted pair cables The TP cable is attached to an 8 pin RJ 45 jack with securing collar Note The twisted pair extenders can also be installed during operation The transmission rate of the Ethernet ports is 10 Mbps or as a fast Ethernet port 100 Mbps No media module is required for data transfer with this extender mod ule Figure 5 1 Basic device with twisted pair extender module Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 61 Extender Modules P1 TO P4 FOR LAN ONLY bs 2 e z lt a a va x a o a amp Figure 5 2 Twisted pair extender EM495 8 Covers For slots 12 and 13 of the twisted pair extenders EM495 8 you can use the cover that can be used on slots 9 through 11 on the basic device Two CV490 4x100 covers are supplied with the twisted pair extender Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 62 C79000 G8976 C186 03 Extender Modules 5 2 Media Module Extender EM496 4 Four Additional Slots for Media Modules By
58. f SCALANCE xX 400 2 2 3 100Base FX Transmission Rate The transmission rate of the optical fast Ethernet ports is 100 Mbps Transmission Mode Transmission with 100Base FX is defined in the IEEE 802 3u standard and is specified as 100 Mbps transmission rate and full duplex Transmission Medium Data transmission is over multimode or single mode fiber optic cable FOC The wavelength is 1310 nm Two FOC types can be used e Multimode FOC The core diameter is 50 um the light source is an LED Many modes light beams are used for signal transmission The propagation times of the light pulses dispersion restrict the maximum range considerably e Single mode FOC The core diameter is 9 or 10 um the light source is a laser diode To transmit a signal only one mode light beam is used greatly reducing dispersion As a re sult the maximum range of single mode FOC is greater than that of multimode FOC Regardless of the type used the outer diameter of the FOC is 125 um Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 27 System Description of SCALANCE xX 400 Transmission Range The maximum transmission range segment length depends on the module se lected and the FOC The range is as follows e 100Base FX module and multimode GFOC 3 km e 100Base FX LD module and single mode FOC 26 km Connectors BFOC connectors are used Operating Instructions for SCALANCE X 400 I
59. f extender available one for twisted pair ports and one for fiber optic ports The twisted pair extender is double the width of a media module and the media module extender is four times the width Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 38 C79000 G8976 C186 03 Product Description of SCALANCE X 400 3 1 1 Power Module The power module is inserted in slot 2 The power can be fed into the power module redundantly over two inputs The two power inputs are isolated from each other there is no power distribution If redun dant power feed in is used the switch is supplied solely by the section of the power module with the higher output voltage The front 4 pin connector is used for the power supply The input voltage is 24 V DC 20 4 28 8 V The signaling contact supplies the fault status at the rear 4 pin connector If there is a fault the contact opens Figure 3 5 Slot of the power module Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 39 Product Description of SCALANCE X 400 Signaling Contact The following can be signaled over a floating signaling contact e Failure of the power supply The power supply monitored is selected in the fault mask e Bad link status of a port wrong connector or no connection to partner device The port monitored is se lected in the fault mask e Change to the DIL switch d
60. f the basic device so that the guide bolts fit into the two holes in the basic device 7 Using a slotted screwdriver with a 2 8 mm wide blade tighten the two captive slug screws on slot 11 The screws lock the two guide bolts so do not use ex cessive force when tightening them 8 Fit a suitable cover on slot 11 of the basic device Note The basic device must not be used permanently without the right side panel Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 87 Installation and Commissioning 6 4 Slot Numbers of the Modules and Covers Specifying the Slot Number The three preinstalled modules the media modules the covers for unused slots and the dummy cover for slot 8 must be labeled with the slot number using the slot number tabs supplied Since the power supply unit is not located on the basic de vice and has slot number 1 start with number 2 for the power module The order for the other modules is in ascending order to the right The applies to any ex tender modules that may be used starting from the left with number 12 Applying the Slot Numbers 1 Place the required slot number in front of the module 2 Place the tongue in the opening on the module 3 Press the slot number into the recess on the front of the housing with your fin ger The slot number breaks out of the wheel Figure 6 8 Slot number tabs Operating Instructions for SCALANCE X 400 Industrial Ethernet Sw
61. figuration with media modules or extender modules must be duplicated Diagnostics Inserting a C PLUG that does not contain the configuration of a compatible device type accidentally removing the C PLUG or general malfunctions of the C PLUG are signaled by the diagnostics mechanisms of the device LEDs WEB based management SNMP and CLI Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 45 Product Description of SCALANCE X 400 Startup Behavior C PLUG X414 3E Startup 1 not found with internal configuration if it exists or with factory defaults 2 empty with internal configuration immediately copies this automatically to the C PLUG 3 written with own X414 3E configu with C PLUG configuration ration data 4 written with third party X414 3E with third party C PLUG configuration configuration data 5 written with configuration data of a with internal configuration red LED on different device type power module and log entry 6 defective with internal configuration red LED on power module and log entry In cases 1 and 2 the configuration data on the Switch CPU and the C PLUG is identical In cases 3 and 5 the configuration data is different and can be synchro nized manually In case 6 you can attempt to reformat the C PLUG with the clean function If problems persist replace the C PLUG Notice In case 4 replacing the switch the D
62. following tools e slotted screwdriver with a 2 8 mm wide blade e slotted screwdriver with a 5 5 mm wide blade Note To remove the extender remove the media modules from slots 13 and 14 When removing a media module extender from an S7 300 rail the basic device remains in position Follow the steps below 1 To remove an extender module use a slotted screwdriver with a 5 5 mm wide blade to open the captive screw between slots 13 and 14 in the lower part of the extender module 2 Remove the cover from slot 11 of the basic device 3 Use a slotted screwdriver with a 2 8 mm wide blade to loosen the two captive slug screws on slot 11 of the basic device in the upper and lower recesses as far as they will go 4 Push the extender module slowly to the right while keeping it straight until the two guide bolts of the extender module are completely outside the holes in the basic device 5 Pull out the lower part of the extender module slightly towards the front and lift it from the S7 300 rail 6 Replace the right side panel of the basic device so that the guide bolts fit into the two holes in the basic device 7 Using a slotted screwdriver with a 2 8 mm wide blade tighten the two captive slug screws on slot 11 The screws lock the two guide bolts so do not use ex cessive force when tightening them 8 Fit a suitable cover on slot 11 of the basic device Note The basic device must not be used permanently without the right side pa
63. ge or destroy circuits In display modes A and C or B and D incorrect inputs are displayed during the time the connectors are swapped over Digital inputs 1 through 4 are connected using a 5 pin connector at the front termi nal block on the DI module yI N Sener Figure 6 11 Pin assignment of connector X1 Inputs 1 through 4 Conn 1 IN1 Digital input 1 IN2 Digital input 2 M4 Ground IN3 Digital input 3 IN4 Digital input 4 Warning The input voltage must not exceed 30 V and must not fall below 30 V other wise the DI module will be destroyed Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 92 C79000 G8976 C186 03 Installation and Commissioning 6 6 4 Digital Input Connectors X2 Digital inputs 5 through 8 are connected using a 5 pin connector at the rear termi nal block on the DI module Z ie CiN v5 Cins ims Figure 6 12 Pin assignment of connector X1 Inputs 5 through 8 Conn 2 IN5 Digital input 5 ING Digital input 6 M5 Ground IN7 Digital input 7 IN8 Digital input 8 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 93 Installation and Commissioning 6 6 5 Connectors for the Twisted Pair Cables The FastConnect Cabling System 94 With the IE FC RJ 45 Plug and the FastConnect cables FC you can achieve a segment length up to 100 m without pat
64. gned for use in high performance networks that will also meet future re quirements Thanks to their modular design the switches can be adapted to the task in hand in terms of number of ports and transmission medium Support of Of fice standards makes the smooth integration of automation networks in existing of fice networks possible The devices are designed for use in switching cubicles and cabinets Technical Options network topologies The modularity of SCALANCE X 400 switches simplifies the expansion of a net work regardless of the network topology You can use a SCALANCE X 400 in the following network topologies e Ring with redundancy manager e Star structure e Line structure The maximum cable length is 26 km for single mode fast Ethernet transmission and 10 km for single mode gigabit transmission Mixed operation within the topol ogy for example between SCALANCE X414 3E and OSMs ESMs is possible re gardless of the structure being used ring with redundancy manager star or line structure Using the SCALANCE X 400 as the redundancy manager in a ring with redun dancy manager provides greater availability If there is an interruption on the con nection between these switches the SCALANCE X 400 used as redundancy man ager acts like a switch and in a very short time creates a line from the ring with re dundant manager As a result a functional end to end structure is restored Operating Instructions for SCALANCE X 400
65. gt 10 g use the 7 300 rail for installation The 35 mm standard rail does not provide adequate support for the twisted pair extender with vibration greater than 10 g For installation you require a slotted screwdriver with a 2 8 mm wide blade Although the captive screw in the lower part between slots 12 and 13 of the ex tender module is not used when installing on a 35 mm standard rail it is neverthe less advisable to remove the media modules Note Make sure that in addition to the extender width of 87 mm there is a clearance of 20 mm to the right of the basic device on the 35 mm standard rail to be able to align the guide bolts of the extender with the holes in the basic device during installation When installing a twisted pair extender on a 35 mm standard rail the basic device remains in position Follow the steps below 1 Remove the cover from slot 11 of the basic device 2 Remove the right hand side panel of the basic device To do this use a slotted screwdriver with a 2 8 mm wide blade to loosen the two captive slug screws on slot 11 in the upper and lower recesses as far as they will go 3 Remove the side panel of the basic device from the basic device to the right Note Keep the panel in a safe place in case the extender needs to be removed again later 4 Place the central groove containing a spring clip on the back of the extender module on the upper edge of the 35 mm standard rail with the module tilted s
66. hes The two devices connected in the configuration exchange data frames with each other to synchronize their operating statuses one device is master and the other slave If there are no problems only the link from the master to the other network segment is active If this link fails for example due to a link down or a device fail ure the slave activates its link as long as the problem persists Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 20 C79000 G8976 C186 03 System Description of SCALANCE X 400 2 2 1 Properties Functionality and Features of SCALANCE X 400 This chapter explains special properties features and options available to you with the SCALANCE X 400 product line The basic device consists of the frame the power supply digital inputs and a Switch CPU SCALANCE X 400 provides a modular structure for the required ports This modu larity simplifies setup and subsequent expansion of complex network topologies to meet current needs e Gigabit technology The basic device has ports with a transmission rate of 1 Gbps for electrical ca bles twisted pair or by adding a gigabit media module for fiber optic cables FO e With SCALANCE X 400 it is possible to split the ring ports into two different slots fast Ethernet module slots 6 and 7 If one of the media modules fails operation can be maintained as a line structure A defective module can be re placed during operation e Diagnostic
67. hes 4 C79000 G8976 C186 03 Correct Usage of Software Products Please note the following regarding the correct usage of software products Caution This software may only be used for the applications described in the catalog or the technical description and only in connection with software products devices or com ponents from other manufacturers which have been approved or recommended by Siemens Before you use the supplied sample programs or programs you have written yourself make certain that no injury to persons nor damage to equipment can result in your plant or process Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 5 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 Preface Purpose of the Operating Instructions These operating instructions describe the functions of the SCALANCE X 400 product line of modular Industrial Ethernet switches and support you during instal lation commissioning and troubleshooting on site You will find information on con figuration in the separate SCALANCE X 400 Configuration Manual Validity of the Operating Instructions These operating instructions are valid for the following products e Industrial Ethernet Switches SCALANCE X414 3E order number 6GK5 414 3FC00 2AA2 e Media module MM491 2 order number 6GK5 491 2AB00 8AA2 e Media module MM491 2LD order number 6GK5 491 2AC00 8AA2 e Media modul
68. igure 4 2 Slots of the MM491 2 media module Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 51 Media Modules Covers Dummy Cover 4 1 2 Fast Ethernet Media Module MM491 2LD 100Base F X The fast Ethernet media module MM491 2LD can be used optionally in slots 6 and 7 of the basic device and when using the media module extender EM496 4 it can also be used in slots 12 through 15 Mixed operation with the fast Ethernet media module MM491 is possible Properties The fast Ethernet media module provides two ports for connecting the single mode FOC The signal is transmitted by laser diode with a wavelength of 1310 nm The maximum cable length is 26 km Connector The connectors are 2x2 BFOC sockets LED Display of the Fast Ethernet Media Module The LED displays of the module are the same as the LEDs of the basic device With optical transmission only a fixed transmission rate and full duplex mode are possible The display in display modes B and C is analogous e In display mode A the current connection status is displayed e In display mode B the fixed transmission rate is displayed e In display mode C the full duplex mode is always displayed e In display mode D you can see whether or not the port is monitored Figure 4 3 Slots of the MM491 2LD media module Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 52 C790
69. in the upper and lower recesses as far as they will go 3 Remove the side panel of the basic device from the basic device to the right Note Keep the panel in a safe place in case the extender needs to be removed again later 4 Place the central groove containing a spring clip on the back of the extender module on the upper edge of the 35 mm standard rail with the module tilted slightly towards the back Make sure that there is adequate clearance between the guide bolts of the extender module and the basic device Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 85 Installation and Commissioning 5 The spring clip must be located behind the edge of the 35 mm standard rail so that it is visible from the rear of the frame 6 Press the extender module down and push in the lower part until you hear it click into place in the standard rail 7 Push the extender module slowly to the left while keeping it straight and with out skewing and check that the two guide bolts on the extender fit into the holes in the basic device Then push the extender module to the left as far as it will go so that it is flush with the right side of the basic device 8 Using a slotted screwdriver with a 2 8 mm wide blade tighten the two captive slug screws on slot 11 The screws lock the two guide bolts so do not use ex cessive force when tightening them 9 Fit the CV490 4x100 cover on slot 11 of the basic de
70. ing Removing the Twisted Pair Extender Installing the Twisted Pair Extender on the S7 300 Rail You require the following tools e slotted screwdriver with a 2 8 mm wide blade e slotted screwdriver with a 5 5 mm wide blade Note Make sure that in addition to the extender width of 87 mm there is a clearance of 20 mm to the right of the basic device on the S7 300 rail to be able to align the guide bolts of the extender with the holes in the basic device during installation When installing a twisted pair extender on an S7 300 rail the basic device remains in position Follow the steps below 1 Remove the cover from slot 11 of the basic device 2 Remove the right hand side panel of the basic device To do this use a slotted screwdriver with a 2 8 mm wide blade to loosen the two captive slug screws on slot 11 in the upper and lower recesses as far as they will go 3 Remove the side panel of the basic device from the basic device to the right Note Keep the panel in a safe place in case the extender needs to be removed again later 4 Remove the two covers from the extender 5 Place the extender module on the edge of the S7 300 rail with the upper groove angled slightly towards the back and tilt the extender towards the back Make sure that there is adequate clearance between the guide bolts of the ex tender module and the basic device In this position the extender module should not be able to slip off however it can be mo
71. ion EN 55081 Class A Noise immunity EN 61000 6 2 2001 Construction Sd SOS Dimensions W x H x D 344 x 145 x 117 mm Weight 3070 g Installation options 35 mm standard rail S7 300 rail Degree of protection IP 20 MTBF information mean time between failure SCALANCE X414 3E Basic device 24 5 years E Twisted Pair extender EM495 8 1 474 9 years K Media module extender EM496 4 2 038 5 years Fast Ethernet media module MM491 2 138 3 years Fast Ethernet media module MM491 2LD 141 8 years P Gigabit media module MM492 2 400 5 years Gigabit media module MM492 2LD 400 5 years 6GK5 492 2AM00 8AA2 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 121 Technical Specifications Figure 7 1 Dimension drawing SCALANCE X414 3E Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 122 C79000 G8976 C 186 03 Technical Specifications 7 2 Media Module MM491 2 100Base FX Connection of end devices or network 2x2 BFOC sockets segments over FOC 100 m 100BaseFX full duplex Power consumption Power consumption FOC lengths 0 3 km 50 125 um multimode fiber 1 dB km at 1310 nm 1200 MHz km 6 dB max permitted FO cable attenuation at 3 dB link power margin Permitted Environmental Con
72. ion of light pulses in fiber optic cable due to signals arriving at different times On multimode FOC the distortion of the output signal is greater than with single mode FOC Display Mode Display mode that indicates various statuses port status power moni DMode toring activated etc The modes can be switched over using a button on the Switch CPU ESM Electrical Switching Module SIMATIC NET Ethernet switch with elec trical ports Fault mask Specifies the desired status good status Deviations from this occur ring during operation are handled as faults FO port Fiber Optic Port Full duplex Two way simultaneous both communication partners can send and receive at the same time Half duplex Two way alternate transmission mode it is only possible to either send or receive over the interfaces at any one time Latency Latency specifies the time taken by frames to pass through a switch This does not include the time required for buffering frames Load Containment With its filtering functions a switch makes sure that local data traffic remains local The local network load of a segment is contained in the originating segment and does not represent extra load on the remain der of the network Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 140 C79000 G8976 C186 03 MDI MDI X MIB Mirroring Modes Multimode OSM Rapid spanning tree Reconfiguration time Glossary Medium Depend
73. ion with media modules provides you with additional op tical ports By using an extender module you can increase the number of ports by a maximum of eight ports 2 2 1 10Base T 100Base TX Transmission Rate The transmission rate of the electrical ports is 10 Mbps or as fast Ethernet ports 100 Mbps Transmission Mode The transmission mode for 10Base T 100Base TX is specified in the IEEE 802 3i IEEE 802 3u standards of the Institute of Electrical and Electronic Engineers Autonegotiation automatic detection of the best transmission modes is standard The order in which they are selected is e 100Base TX full duplex e 100Base TX half duplex e 10Base T full duplex e 10Base T half duplex Two communication modes are possible e Half duplex mode two way alternate it is only possible to either send or receive over the inter faces at any one time e Full duplex mode two way simultaneous both communication partners can send and receive at the same time Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 24 C79000 G8976 C186 03 System Description of SCALANCE xX 400 Connections to other switches can use half or full duplex connections to hubs are possible only in half duplex mode Transmission medium Data transmission at 10 Mbps and at 100 Mbps is over two wire pairs pin 1 2 3 6 of the twisted pair cable For 10 Mbps at least a category 3 Cat 3 and for 100 Mbps at least a four wire ca
74. itches 88 C79000 G8976 C186 03 Installation and Commissioning 6 5 Factory Defaults DIL Switches When supplied the four DIL switches on the switch are set to OFF as default Notice Before starting up for the first time check the switch settings e RM is set to OFF This means that the redundancy manager function is disabled e STBY is set to OFF This switch is intended for future applications and is does not cur rently have any function e R1 R2 are set to OFF Both electrical gigabit ports on slot 5 are defined as ring ports Further Device Properties With R1 and R2 ring redundancy is enabled when the device ships Notice In this mode RSTP STP cannot be activated C PLUG When delivered the C PLUG is empty and is initialized with the factory settings when first started up All subsequent configuration changes are automatically adopted in the internal memory of the SCALANCE X414 3E and in the C PLUG Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 89 Installation and Commissioning 6 6 Ports 6 6 1 Power Supply Connectors X1 Polarity Reversal Protection X1 X2 The two 4 pin male connectors X1 X2 for the power supply and the signaling contact have no polarity reversal protection If the connectors are accidentally swapped over this does not cause damage or destroy circuits Normal functionality is however not available while the connectors are swappe
75. lightly towards the back Make sure that there is adequate clearance between the guide bolts of the extender module and the basic device 5 The spring clip must be located behind the edge of the standard rail so that it is visible from the rear of the frame Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 79 Installation and Commissioning 6 Press the extender module down and push in the lower part until you hear it click into place in the 35 mm standard rail 7 Push the extender module slowly to the left while keeping it straight and with out skewing and check that the two guide bolts on the extender fit into the holes in the basic device Then push the extender module to the left as far as it will go so that it is flush with the right side of the basic device 8 Using aslotted screwdriver with a 2 8 mm wide blade tighten the two captive slug screws on slot 11 The screws lock the two guide bolts so do not use ex cessive force when tightening them 9 Fit the CV490 4x100 cover to slot 11 of the basic device and slots 12 and 13 of the twisted pair extender 5 Figure 6 5 Installing the twisted pair extender on the 35 mm standard rail Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 80 C79000 G8976 C186 03 Installation and Commissioning Removing the Twisted Pair Extender from the 35 mm Standard Rail To remove the device you require a slotte
76. mber of available ports in the basic device SCALANCE X414 3E from 14 to 18 On six ports data transmission is also possible over fiber optic cable instead of TP cable Module Procedure Cabling Connec Segment Wave Type tor Length length MM491 2 100Base FX Multimode BFOC 3 km 1310 nm MM491 2LD 100Base FX Single BFOC 26 km 1310 nm mode MM492 2 1000Base SX Multimode SC 750m 850 nm duplex MM492 2LD 1000Base LX Single SC 10 km 1310 nm mode duplex Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C 186 03 49 Media Modules Covers Dummy Cover Note It is possible to insert and remove the media modules during operation Before inserting a media module remove the cover and cap from the slot Please put these away for safe keeping If you remove a media module close the the terminal strip with the cap and and the slot with the cover Options for Slot 5 Slot 5 of the basic device has two RJ 45 jacks for connecting TP cables The pos sible data transmission rates on electrical connections are 10 100 or 1000 Mbps An optical gigabit module in slot 5 allows data transmission with multimode or sin gle mode FOC In this case the two RJ 45 jacks can no longer be used Options for Slots 6 and 7 Slots 6 and 7 do not have any ports but allow two optical fast Ethernet modules to be inserted each with ports This gives you the opportunity of
77. ndustrial Ethernet Switches 28 C79000 G8976 C186 03 System Description of SCALANCE xX 400 2 2 4 1000Base SX Transmission Rate The transmission rate of the optical gigabit ports is 1 Gbps Transmission Mode Transmission with 1000Base FX is defined in the IEEE 802 3z standard and is specified as 1000 Mbps transmission rate and full duplex Transmission Medium Data is transmitted over multimode FOC The wavelength is 850 nm The core diameter of the multimode FOC is 50 um the light source is an LED Many modes light beams are used for signal transmission The propagation times of the light pulses dispersion restrict the maximum range considerably Transmission Range The maximum transmission range segment length is 750 m when using SIMATIC NET fiber optic multimode FOC with SC duplex connectors Connectors SC duplex female connectors are used Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 29 System Description of SCALANCE xX 400 2 2 5 1000Base LX Transmission Rate The transmission rate of the optical gigabit ports is 1 Gbps Transmission Mode Transmission with 1000Base LX is defined in the IEEE 802 3z standard and is specified as 1000 Mbps transmission rate and full duplex Transmission Medium Data is transmitted over single mode FOC The wavelength is 1310 nm The core diameter of the single mode FOC is 9 or 10 um the light source is a laser diode To tran
78. nel 84 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 Installation and Commissioning Installing the Media Module Extender on the 35 mm Standard Rail AN Caution If the SCALANCE X 400 with extender is liable to severe vibration gt 10 g use the 7 300 rail for installation The 35 mm standard rail does not provide adequate support for the media module extender with vibration greater than 10 g For installation you require a slotted screwdriver with a 2 8 mm wide blade Although the captive screw in the lower part between slots 13 and 14 of the ex tender module is not used when installing on a 35 mm standard rail it is neverthe less advisable to remove the media modules Note Make sure that in addition to the extender width of 155 mm there is a clearance of 20 mm to the right of the basic device on the 35 mm standard rail to be able to align the guide bolts of the extender with the holes in the basic device during installation Note Protective caps and CV490 2x100 covers must be fitted to all slots without media modules When installing a media module extender on a 35 mm standard rail the basic de vice remains in position Follow the steps below 1 Remove the cover from slot 11 of the basic device 2 Remove the right hand side panel of the basic device To do this use a slotted screwdriver with a 2 8 mm wide blade to loosen the two captive slug screws on slot 11
79. ngle mode transmission resulting in shorter transmission distances Optical Switching Module SIMATIC NET Ethernet switch with optical ports The Rapid Spanning Tree protocol RSTP allows redundant transmis sion paths This prevents circulating frames and if a fault develops provides an alternative path within one second reconfiguration time The time required to restore a functional configuration if a device fails or a network cable is interrupted Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 141 Glossary Redundancy manager Switch in a ring topology that does not forward any frames between its RM Ring port Segment Signaling Contact Single mode SNMP Spanning Tree 142 ring ports if there are functioning connections between all other switches As soon as a connection between two switches is inter rupted the redundancy manager forwards frames between its ring ports and so restores an intact connection between all switches Two ports in a switch via which it is connected with other switches to form a ring One switch must be configured as the redundancy man ager in the ring This sends test frames via the ring ports that are for warded by all the ring ports of the other switches in the ring This makes sure that the ring does not have any interruptions In the Ethernet bus system transceivers connected together over the bus cable along with the node
80. not absolutely nec essary to remove the covers and the blind cover although this does make it easier to handle the basic device Notice When installing the SCALANCE X414 3E hold it by the backplane and not by the modules otherwise the device may be damaged To install the device follow the steps below 1 Place the central groove containing two spring clips on the back of the basic device on the upper edge of the standard rail with the device tilted slightly to wards the back Make sure that the two spring clips are located behind the edge and are visible from the rear of the installation frame 2 Press the basic device down and push in the lower part until you hear it click into place in the standard rail 3 Adjust the basic device to the right or left until it is in the required position Note Only horizontal installation permitted ventilation slit top bottom Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 Installation and Commissioning Figure 6 2 Installation on a 35 mm standard rail Removing from the 35 mm Standard Rail Since the two captive screws in slot 7 and between slots 8 and 9 are not used to secure the device when removing it from a 35 mm standard rail it is not absolutely necessary to remove the covers and the blind cover although this does make it easier to handle the basic device Notice When removing the SCALANCE X414 3E hold it by the backplane
81. ommissioning 6 3 2 Installing Removing the Media Module Extender Installing the Media Module Extender on the S7 300 Rail You require the following tools e slotted screwdriver with a 2 8 mm wide blade e slotted screwdriver with a 5 5 mm wide blade Note Make sure that in addition to the extender width of 155 mm there is a clearance of 20 mm to the right of the basic device on the S7 300 rail to be able to align the guide bolts of the extender with the holes in the basic device during installation Note Protective caps and CV490 2x100 covers must be fitted to all slots without media modules When installing a media module extender on an S7 300 rail the basic device re mains in position Follow the steps below 1 2 82 Remove the cover from slot 11 of the basic device Remove the right hand side panel of the basic device To do this use a slotted screwdriver with a 2 8 mm wide blade to loosen the two captive slug screws on slot 11 in the upper and lower recesses as far as they will go Remove the side panel of the basic device from the basic device to the right Note Keep the panel in a safe place in case the extender needs to be removed again later Remove the four covers from the extender Place the extender module on the edge of the S7 300 rail with the upper groove angled slightly towards the back and tilt the extender towards the back Make sure that there is adequate clearance between the guide bolt
82. on 2 gt 3 3 So o z O A See 6 8 3 See 6 8 4 Switch CPU DI Module See ae Transmission Half full du Fault mask rate plex Ports See 6 8 6 i i o Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 6 8 1 Installation and Commissioning Startup Behavior of the SCALANCE X414 3E During device startup the red LED on the power module signals the current status of the device For more detailed information refer to the following table During de vice startup LED on Device starting up or fault occurred LED off Device startup completed without problems LED flashes Keyboard entry over serial inter face or bad firm ware image During ope ration Fault occurred Problem free op eration Figure 6 23 Fault LED on the power module Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 107 Installation and Commissioning 6 8 2 Selecting the Display Modes Press the SELECT SET button on the Switch CPU until the DM1 and DM2 light up on the CPU in the required combination The selected display mode is then ac tivated There is an automatic switchover to DMode A if the button is not pressed for longer than one minute
83. on pa rameters for example 10 100 Mbps full half duplex are negotiated automatically between the devices The C PLUG configuration plug is an exchangeable memory medium of storing the configuration data If the device is replaced the configu ration can be adopted by swapping the C PLUG Command Line Interpreter Terminal based configuration option for the SCALANCE X 400 The CLI can be used both over the serial port of the Switch CPU and with TELNET over every Ethernet port To ensure that the CSMA CD protocol functions correctly the propaga tion time of a data packet from one node to another is restricted This propagation time results in a spatially limited span for the network de pending on the data rate known as the collision domain Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 139 Glossary Connection monitor With regular link test pulses SCALANCE X 400 monitors the con ing nected TP and FO cable segments for short circuits or interruptions The SCALANCE does not send data to a segment from which it is not receiving link test pulses Digital input A digital input is used to acquire binary file information A state change can be logged in the Log Table or reported by E mail or traps The voltage levels between 30 V and 3 V correspond to logical state 0 voltage levels between 13 V and 30 V correspond to logical state 15 Dispersion Broadening and distort
84. power supplies In this case you press the button for 5 seconds in DMode A or DMode D After 3 seconds the two LEDs DM1 and DM2 start to flash You can cancel the procedure by releasing the button before the 5 seconds have elapsed If however you press the button for a fur ther 2 seconds the current states of all ports and the states of the power sup plies L1 and L2 are included in the fault mask The previous fault mask is then overwritten Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 105 Installation and Commissioning 6 8 LED Display Overview 106 The following table shows the states indicated by the LEDs in the various display modes For more detailed information refer to the subsections listed in the first col umn LED Display Display Display Display Mode A Mode B Mode C Mode D Problem signaling contact opens Power supply L1 is applied Power supply L1 is moni tored Power supply L2 is applied Power supply L2 is moni tored IN1 IN5 Signal at in Signal at input Signal at input Signal at input put IN1 IN5 IN1 IN5 IN2 IN6 Signal at in Signal at input Signal at input Signal at input put IN2 ING IN2 ING IN3 IN7 Signal at in Signal at input Signal at input Signal at input put IN3 IN7 IN3 IN7 IN4 IN8 Signal at in Signal at input Signal at input Signal at input put IN4 IN8 IN4 IN8 RM__ Devicei is operating as RM C Reserved no functi
85. precautions that shall be taken when operated in an air ambient of 50 C 60 C Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 67 Installation and Commissioning 6 1 1 Installing Uninstalling with an S7 300 Rail Installing on an S7 300 Rail For installation you require a slotted screwdriver with a 5 5 mm wide blade Notice When installing the SCALANCE X414 3E hold it by the backplane and not by the modules otherwise the device may be damaged To install the device follow the steps below 1 Tilt the basic device slightly towards the back with the upper groove on the edge of the S7 300 rail and push in towards the bottom In this position the basic device should not slip off but it can be adjusted horizontally to the left or right until the required position is achieved 2 Remove the covers from slots 7 and 9 see section 6 2 2 and the dummy cover from slot 8 see section 6 2 3 If media modules are inserted remove the fast Ethernet media module instead of the cover from slot 7 see section 6 2 1 3 Using a screwdriver with a 5 5 mm wide blade tighten the two captive screws in the backplane at slot 7 and between slots 8 and 9 until the basic device can no longer be moved to the side Note Only horizontal installation permitted ventilation slit top bottom Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 68 C79000 G8976 C186 03 Installation
86. s Certificates Note for Australia The product complies with the requirements of the AS NZS 2064 standard Class A UL Approval Information Technology Equipment Underwriters Laboratories UL complying with Standard UL 60950 1 Report number E115352 UL Approval Industrial Control Equipment Underwriters Laboratories UL complying with Standard UL 508 Report number E85972 CSA Approval Information Technology Equipment CSA Certification Mark Canadian Standard Association CSA C22 2 No 60950 1 03 CSA Approval Industrial Control Equipment CSA Certification Mark Canadian Standard Association CSA C22 2 No 14 M91 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 134 C79000 G8976 C186 03 Approvals Certificates cULus Approval Information Technology Equipment cULus Listed 60E9 I T E Underwriters Laboratories Inc complying with e UL 60950 1 Information Technology Equipment e CSA C22 2 No 60950 1 03 cULus Approval Industrial Control Equipment cULus Listed 69B1 Underwriters Laboratories Inc complying with e UL508 e CSA C22 2 No 14 M91 cULus Approval Hazardous Location cULus Listed 21BP I T E FOR HAZ LOC Underwriters Laboratories Inc complying with e UL 60950 1 Information Technology Equipment e CSA C22 2 No 60950 1 03 e UL 1604 and 2279 Hazardous Location Approved for use in Cl 1 Div 2 GP A B C D T4 Cl 1 Zone 2 GP IIC T4 Cl 1 Zone 2 Aex nC IIC T4 Note Wh
87. s Remote diagnostic options are available with Web based management TelNet or SNMP e The basic device has a signaling contact for local operator control e An Ethernet interface is available for diagnostics and management purposes Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 21 System Description of SCALANCE xX 400 22 e C PLUG When replacing a device the C PLUG can be removed and inserted in the new device so that the configuration can be retained e VLAN SCALANCE X 400 has port based support of virtual networks VLAN A physi cal network can be divided into several virtual networks This results in less net work load compared with other defined VLANs e Spanning Tree Rapid Spanning Tree SCALANCE X 400 can process both the Spanning Tree Protocol STP and the Rapid Spanning Tree Protocol RSTP This prevents circulating packets and in the event of a link going down quickly provides an alternative path With the spanning tree protocol the reconfiguration time is between 20 and 30 seconds with rapid spanning tree it is approximately one second Spanning tree rapid spanning tree is disabled as default Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 Components of SCALANCE X 400 System Description of SCALANCE xX 400 The following table shows the components of SCALANCE X 400 Component Function Foe Basic device
88. s connected over patch cables form a segment Several such segments can be connected via repeaters When using twisted pair and fiber optic cables each subsection forms a segment Floating relay contact via which the detected error states can be sig naled In single mode transmission the pulse is transmitted by a straight mode wave Attenuation is mainly caused by physical absorption and dispersion as well as by mechanical bending The amount of attenua tion depends among other things on the wavelength of the input light Single mode fiber optic cables have an outer diameter of 125 um and 9 or 10 um core diameter The smaller core diameter degrades the pulse edges less than multimode transmission and allows greater transmis sion distances Simple Network Management Protocol Standardized protocol for transporting network management information The Spanning Tree protocol STP allows redundant transmission paths This prevents circulating frames and if a fault develops pro vides an alternative path within 20 30 seconds reconfiguration time Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 Glossary Store and forward In this switching technique the entire frame is read in before it is for warded by the switch A packet is only passed on if it is error free TELNET With this protocol an interactive connection can be established to an other device in the LAN or on the Internet
89. s of the ex tender module and the basic device In this position the extender module should not be able to slip off however it can be moved horizontally in both di rections Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 Installation and Commissioning 6 Push the extender module slowly to the left while keeping it straight and with out skewing and check that the two guide bolts on the extender fit into the holes in the basic device Then push the extender module to the left as far as it will go so that it is flush with the right side of the basic device 7 Using a slotted screwdriver with a 5 5 mm wide blade tighten the captive screw between slots 13 and 14 in the lower part of the extender module 8 Using aslotted screwdriver with a 2 8 mm wide blade tighten the two captive slug screws on slot 11 The screws lock the two guide bolts so do not use ex cessive force when tightening them 9 Fit the CV490 4x100 cover on slot 11 of the basic device Make sure that the media module terminal strips of slots not occupied by media modules have protective caps fitted and that the CV490 2x100 covers are in place Figure 6 6 Installing the media module extender on the S7 300 rail Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 83 Installation and Commissioning Removing the Media Module Extender from the S7 300 Standard Rail You require the
90. see the relevant symbols Notice Fiber optic cable connectors are susceptible to contamination and mechanical damage to the face Protect open connections with the supplied dust caps Figure 6 19 BFOC plug with fast Ethernet media module MM491 2 Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 100 C79000 G8976 C186 03 Installation and Commissioning 6 7 Operator Controls 6 7 1 DIL Switches Below the labeling strip on the Switch CPU on slot 4 there are four DIL switches These DIL switches can have one of two states ON OFF SIEMENS Figure 6 20 Power module digital inputs and Switch CPU with controls Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 101 Installation and Commissioning Notice Changing the switch settings during operation causes fault displays and activates the signaling contact The settings are adopted only after the device is restarted The RM switch allows you to configure the SCALANCE X414 3E as a redundancy manager in a ring with redundancy manager The STBY switch is reserved for future functionality and does not currently have any function With switches R1 and R2 you can specify either the two ports in slot 5 the two ports in slot 6 or the first ports of slots 6 and 7 as ring ports If you do not want any ring ports defined both switches must be set to ON Switch Status Meaning RM OFF SCALANCE X414
91. smit a signal only one mode light beam is used greatly reducing dispersion As a result the maximum range of single mode FOC is greater than that of multimode FOC Transmission Range The maximum transmission range segment length is 10 km for single mode FOC Connectors SC duplex female connectors are used Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 30 C79000 G8976 C186 03 System Description of SCALANCE xX 400 2 3 Compatibility of SCALANCE X 400 Compatibility List The following products and devices are compatible with SCALANCE X 400 End devices All SIMATIC NET products with a TP port can be connected to the ports of SCALANCE X 400 Industrial Ethernet Switches Network components in a line or star structure ESM OSM OMC TP cable max 6 m long SCALANCE X 100 SCALANCE X 200 SCALANCE X 200IRT SCALANCE W 700 Network components in a ring structure with SCALANCE X 400 as RM ESM OSM SCALANCE X 200 SCALANCE X 200IRT Redundant linking of 100 Mbps networks over FO cable The redundant optical linking of networks is allowed only with the devices ITP 53 with order number 6GK1 105 2AD10 and the OSM BC 08 with order number 6GK1 105 4AA00 using the ESM OSM function standby master and standby slave Note All compatibility information assumes the correct use of the TP and FOC cables Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976
92. snsesnenenneeeenens 6 1 Installing Removing the SCALANCE X414 3E ccccccceeseeeceeeeeeeesseeeeeeeees 6 1 1 Installing Uninstalling with an S7 300 Rail c cccecceeeeeeeeeeeeteeeeeteeeeeesaeeteaes 6 1 2 Installing Uninstalling with a 35 mm Standard Rail ccccceeeeeeeeeeeeees 6 2 Installing Removing the Media Modules Covers and Dummy Cover Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 9 Contents 6 2 1 Installing Removing a Media Module eccceeeseceeeeeeeeeeeeeeeeueeeeeeneeeeenenaes 6 2 2 Fitting Removing the Covers ss essesssseerneenrrearndnnreennddnanennddnnntanadun neen nddna nennen naa 6 2 3 Fitting Removing a Dummy COVEr sssseeesrresssrnrseennaesannaneennaanannantennaanannnaneenna 6 3 Installing Removing Extender Modules 2 cccceceeeceeeeeeeeeeeeeeeeesesaeeeeeeees 6 3 1 Installing Removing the Twisted Pair Extender ccccccscceeeeeeeeeeeesteeeeees 6 3 2 Installing Removing the Media Module Extender ccccceeceeeeereeseeeeeees 6 4 Slot Numbers of the Modules and Covers ccccceesceeeeeessteeeeeenneeeeetieeeeeeenaes 6 5 Factory Defaults encrenca E EA E E 6 6 Po e T T eed A E E T E ete eevee 6 6 1 Power Supply Connectors X1 0 ccccceeeeeeeeeeeeeneeeeeecneeeeeeeceeeeeeaeeeeesnieeeeneaes 6 6 2 Connectors of the Signaling Contact and Grounding Strap X2 6 6 3 Digital Input Connectors
93. stallation and Commissioning In display mode C the current mode half duplex full duplex is indicated Port Color Status Meaning P1 off Port operating in half duplex P2 P3 P4 Green on Port operating in full duplex P1 P2 P3 P4 Power Module LEDs DI LEDs CPU LEDs Port LEDs Figure 6 31 Mode display full half duplex of port 1 Note If there is a link fault and the type of transmission is fixed autonegotiation off in DMode C the desired status in other words the set type of transmission full or half duplex continues to be displayed If there is a link fault and autonegotiation is active the port LED goes off Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 115 Installation and Commissioning Port Statuses in DMode D In display mode D you can see whether or not the port is monitored Port Color Status Meaning P1 off The port is not monitored in other P2 words if a link is not established P3 at the port this does not trigger P4 the signaling contact Green on Port is monitored in other words if there is no link established at the port for example cable not plugged in or connected device turned off this triggers the sig naling contact and the fault state is adopted P1 P2 P3
94. switches to the central SCALANCE X414 3E it is also possible to connect one or more end de vices Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 16 C79000 G8976 C186 03 Introduction to Industrial Ethernet Switches Configuration Example Sample configurations electrical optical with SCALANCE X 400 SCALANCE X 200 SIMATIC S7 300 400 SIMATIC ET 200 and operator panel as end devices ET 200S ET 200S Figure 1 3 Star structure Electrical iv mn FE SCALANCE ale SCALANCE spay X206 1 sp x206 E DaM Uo p aii S7 400 a a i ET 200S ET 200S Figure 1 4 Star structure Optical Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 17 Introduction to Industrial Ethernet Switches 1 2 3 Line Structure Functional Description Line structures can be implemented with the SCALANCE X414 3E The cascading depth and total span of a network are limited only by the signal propagation times of the communication connections Properties of the Line Structure Each SCALANCE X414 3E communicates over a TP or FO cable with a neighbor ing switch Communication is possible over the optical ports in slots 5 6 or 7 or over the electrical ports in slots 5 and 9 to 11 With the fault mask it is possible to monitor the port states using the signaling contact In addition to interconnecting
95. t 1 equipped with MM491 2 or with MM491 2LD allows operation of an optical fast Ethernet ring with redundancy manager Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 14 C79000 G8976 C186 03 Introduction to Industrial Ethernet Switches Configuration Example Sample configurations with SCALANCE X414 3E SIMATIC S7 200 300 400 op erator control and monitoring system H system and PC as end devices TT Ee rT T A En wii a Ae SCALANCE i fi X 400 tt ed il Figure 1 1 I SAGs S7300 penn ay all Fiber Optic oli T 1 Figure 1 2 Ring with FO cable and redundancy manager Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 15 Introduction to Industrial Ethernet Switches 1 2 2 Star Structure Functional Description Star structures can be implemented with the SCALANCE X414 3E The cascading depth and total span of a network are limited only by the signal propagation times of the communication connections Properties of a Star Structure Each SCALANCE X414 3E communicates over a TP or FO cable with a central switch with which all other switches are also connected within a star structure Communication is possible over the optical ports in slots 5 6 or 7 or over the elec trical ports in slots 5 and 9 to 11 With the fault mask it is possible to monitor the port states using the signaling contact In addition to connecting the
96. the switches it is also possible to connect one or more end devices to every SCALANCE X414 3E Configuration Example Sample configuration with SCALANCE X414 3E SIMATIC S7 300 400 and opera tor panel as end devices Te ee E eegee j an an __ lh J aii Gin aii in atii ET 200S ET 200S ET 200S ET 200S Figure 1 5 Line structure Optical Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 18 C79000 G8976 C186 03 Introduction to Industrial Ethernet Switches 1 2 4 Redundant Linking of Network Segments The example of redundant linking of two network segments as shown here is pos sible only when linking between X414 because the standby function of the X414 is required SCALANCE X414 3E ig E I S I SCALANCE X 414 3E le Figure 1 6 Redundant linking of two subnets In this case network segments are rings with a redundancy manager RM The rings can also be interrupted at one point linear topology For a redundant link as shown in the figure two devices must be configured within a network segment This configuration is set in Web Based Management Com mand Line Interface or using SNMP access For more detailed information refer to the Configuration Manual SCALANCE X 400 Industrial Ethernet Switches Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 19 Introduction to Industrial Ethernet Switc
97. ual or in the warning notes are defined as persons who are familiar with the installation assembly startup and operation of this product and who possess the relevant qualifications for their work e g e Training in or authorization for connecting up grounding or labeling circuits and devices or systems in accordance with current standards in safety technology e Training in or authorization for the maintenance and use of suitable safety equip ment in accordance with current standards in safety technology e First aid qualification Correct Usage of Hardware Products Please note the following regarding the correct usage of hardware products Caution This device may only be used for the applications described in the catalog or the tech nical description and only in connection with devices or components from other manufacturers which have been approved or recommended by Siemens This product can only function correctly and safely if it is transported stored set up and installed correctly and operated and maintained as recommended Before you use the supplied sample programs or programs you have written yourself make certain that no injury to persons nor damage to equipment can result in your plant or process EU Directive Do not start up until you have established that the machine on which you intend to run this component complies with the directive 89 392 EEC Operating Instructions for SCALANCE X 400 Industrial Ethernet Switc
98. ular importance and that will be of benefit to the user Copyright Siemens AG 1998 to 2005 All rights reserved The reproduction transmission or use of this document or its contents is not permitted without express written authority Offenders will be liable for damages All rights including rights created by patent grant or registration of a utility model or design are reserved Siemens AG Automation and Drives Industrial Communication Postfach 4848 D 90327 N rnberg Siemens Aktiengesellschaft Disclaimer We have checked the contents of this manual for agreement with the hardware and software described Since deviations cannot be precluded entirely we cannot guarantee full agreement However the data in this manual are reviewed regularly and any necessary corrections included in subsequent editions Suggestions for improvement are welcome C79000 G8976 C 186 03 Technical data subject to change Printed in the Federal Republic of Germany 2 Trademarks SIMATIC SIMATIC NET SCALANCE and SIMATIC NET Networking for Indus try are registered trademarks of Siemens AG Third parties using for their own purposes any other names in this document which re fer to trademarks might infringe upon the rights of the trademark owners Safety Instructions Regarding your Product Before you use the product described here read the safety instructions below thor oughly Notice When using a SCALANCE X 400 in the ring
99. uring operation Possible inconsistency between the switch setting and the actual operating state The switch setting is adopted only after a restart If the SCALANCE X414 3E is set as the redundancy manager the following errors are also reported e Bad link status of the ring ports regardless of the status of the fault mask e Configuration of a second SCALANCE X414 3E as redundancy manager in the same ring Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 40 C79000 G8976 C186 03 Product Description of SCALANCE X 400 3 1 2 Digital Inputs DI Module The digital input module is located in slot 3 and provides the user with eight digital inputs The cables are connected to the bottom of the module by two 5 pin connec tors Figure 3 6 LEDs of the digital input module Depending on the configuration the states of the digital inputs can be used to send E mails and or entries to the logbook of the SCALANCE X414 3E It is also possible to read the statuses over SNMP Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 41 Product Description of SCALANCE X 400 3 1 3 Switch CPU The Switch CPU is in slot 4 The CPU has four DIL switches for configuring the device This module also has four LEDs for displaying parameter assignments that can be modified by the user with the DIL switch and a SELECT SET button
100. ustrial Ethernet Switches C79000 G8976 C186 03 65 Extender Modules Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 66 C79000 G8976 C186 03 Installation and Commissioning 6 6 1 ZN Installing Removing the SCALANCE X414 3E Warning SCALANCE X 400 is designed for operation with safety extra low voltage SELV This means that only safety extra low voltages SELV complying with IEC950 EN60950 VDE0805 can be connected to the power supply terminals The power supply unit for the 24 V DC supply must comply with NEC Class 2 voltage range 20 4 28 8 V DC current requirement max 2 A If the device is supplied with power redundantly both power supply units together must comply with NEC Class 2 Exceptions e Power supply with PELV according to VDE 0100 410 is also possible if the generated rated voltage does not exceed the voltage limits 25 V AC or 60 V DC e Power supply by a SELV power source according to IEC 60950 or PELV power source according to VDE 0100 410 without limited power is also per mitted if suitable fire protection measures are taken by Installation in a cabinet or suitable enclosure Installation in a suitably equipped closed room Caution The subject unit must be located in a Restricted Access Location where access can only be gained by SERVICE PERSONNEL or by USERS who have been in structed about the reasons for the restrictions applied to the location and about any
101. ved horizontally in both di rections Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 76 C79000 G8976 C186 03 Installation and Commissioning 6 Push the extender module slowly to the left while keeping it straight and with out skewing and check that the two guide bolts on the extender fit into the holes in the basic device Then push the extender module to the left as far as it will go so that it is flush with the right side of the basic device 7 Using a slotted screwdriver with a 5 5 mm wide blade tighten the captive screw between slots 12 and 13 in the lower part of the extender module 8 Using a slotted screwdriver with a 2 8 mm wide blade tighten the two captive slug screws on slot 11 The screws lock the two guide bolts so do not use ex cessive force when tightening them 9 Fit the CV490 4x100 cover to slot 11 of the basic device and slots 12 and 13 of the twisted pair extender Figure 6 4 Installing the twisted pair extender on the S7 300 rail Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 77 Installation and Commissioning Removing the Twisted Pair Extender from the S7 300 Rail You require the following tools e slotted screwdriver with a 2 8 mm wide blade e slotted screwdriver with a 5 5 mm wide blade When removing a twisted pair extender from an S7 300 rail the basic device re mains in position Follow the steps below 1 To remove
102. vice Make sure that the media module terminal strips of slots not occupied by media modules have protective caps fitted and that the CV490 2x100 covers are in place Figure 6 7 Installing the media module extender on the 35 mm standard rail Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 86 C79000 G8976 C186 03 Installation and Commissioning Removing the Media Module Extender from the 35 mm Standard Rail To remove the device you require a slotted screwdriver with a 2 8 mm wide blade Although the captive screw in the lower part between slots 13 and 14 of the ex tender module is not used on a 35 mm standard rail it is nevertheless advisable to remove the media modules When removing a media module extender from a 35 mm standard rail the basic device remains in position Follow the steps below 1 Remove the cover from slot 11 of the basic device 2 Use a slotted screwdriver with a 2 8 mm wide blade to loosen the two captive slug screws on slot 11 of the basic device in the upper and lower recesses as far as they will go 3 Push the extender module slowly to the right while keeping it straight until the two guide bolts of the extender module are completely outside the holes in the basic device 4 Push the media module extender down until the lower part can be pulled away from the standard rail to the front 5 Lift the extender module up and off the 35 mm standard rail 6 Replace the right side panel o
103. we are obliged to point out that the product described is intended solely for installation in a machine Before the final product can be put into operation it must be tested to ensure that it conforms with the directive 89 392 EEC Note for the Manufacturers of Machines This product is not a machine in the sense of the EU directive on machines There is therefore no declaration of conformity for the EU directive on machines 89 392 EEC If the product is part of the equipment of a machine it must be included in the pro cedure for obtaining the declaration of conformity by the manufacture of the ma chine Installation Guidelines The products meet the requirements if you adhere to the installation and safety in structions contained in these Operating Instructions SIMATIC NET Industrial Ethernet SCALANCE X 400 and in the following documentation SIMATIC NET Industrial Twisted Pair and Fiber Optic Networks Manual 2 This documentation is available on the Internet at http support automation siemens com WW view en 8763736 Warning Personal injury and damage to property may occur The installation of expansions that are not approved for SIMATIC NET products or their target systems may violate the requirements and regulations for safety and electromagnetic compatibility Only use expansions that are approved for the system Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 133 Approval
104. y DQS certificate registration no 2613 The DQS certificate is recognized in all IQNet countries Reg no 2613 Devices connected to the system must meet the relevant safety regulations The EU declaration of conformity is available for the responsible authorities according to the above mentioned EU directive at the following address Siemens Aktiengesellschaft Automation and Drives Industrial Communication SIMATIC NET Postfach 4848 D 90327 Nuernberg Germany This declaration certifies compliance with the directives named above but does not guarantee any specific properties Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches C79000 G8976 C186 03 137 Approvals Certificates Operating Instructions for SCALANCE X 400 Industrial Ethernet Switches 138 C79000 G8976 C186 03 Glossary Aging time Autocrossover Autonegotiation C Plug CLI Collision domain The aging time is the time after which a learned MAC address is dis carded if a SCALANCE X 400 has not received frames with this sender address during this time Technique with which a TP port is automatically switched over between MDI and MDI X assignment to make a connection independent of the port assignment of the device being attached This means that cross over cables are not required The autocrossover function can only be used when the port is set to autonegotiation mode Procedure standardized by IEEE 802 3 in which the transmissi

Download Pdf Manuals