Home

Sharp AF-Q60PX User's Manual

image

Contents

1. Stool LOCATION e The air conditioner should be installed in a solid window to minimize noise and vibration For safe installation repairs replacement and secure positioning make sure the window is solid and level e The room air conditioner must be installed in an area within reach of a properly rated grounded outlet e Use of extension cords of any kind is not recommended e Never place any obstacles around the air inlet INSTALLATION INSTRUCTIONS ACCESSORIES Window sash seal Top mounting rail Foam top window gasket Right accordion panel Left accordion panel ie Top mounting rail seal strip Type A 6 Type B 3 Type C 5 Window locking bracket 1 a G Remote Control SUGGESTED TOOLS 1 Screw driver medium size Phillips 2 Tape measure or ruler 3 Knife or scissors INSTALLATION INSTRUCTIONS INSTALLATION WARNING Make sure the unit is turned off and unplugged before installing Sash Cut the window sash foam seal adhesive type to the proper length and attach it to the underside of the window sash Window sash foam seal adhesive type Remove the air conditioner from the case Place the unit on floor a bench or a table Use protective
2. see FIG 1 1 place the unit into the window opening so the bottom of the air conditioner frame is against the window sill FIG 6 Carefully close the window behind the top rail of the unit 4 Keep a firm grip on the air conditioner carefully Extend the side panels out against the window frame FIG 7 Drive 4 4 19mm Type C locking screws through frame holes into window sash FIG 8A and FIG 8B FIG 8A SCREW FIG 8B SCREW SCREW SCREW INSTALLATION INSTRUCTIONS window lock with 3 4 19 mm Type C screw i as shown FIG 9 Window FIG 9 Add wood as shown in FIG 11 or remove storm window before air conditioner is installed T To secure lower sash in place attach right angle If AC iS Blocked by Sto rm FIG 11 SASH BOARD STORM WINDOW THICKNESS FRAME AS REQUIRED OR OTHER 1 12 MIN OR PROPER OBSTRUCTION 88 mm PITCH TO a REAR ALONG ENTIRE SILL FASTEN WITH NAILS OR SCREWS Cut foam seal and insert in the space between the upper and lower sashes FIG 10 If Storm Window Frame must remain be sure the drain holes or slots are not caulked or painted shut FIG 10 Accumulated Rain Water or Condensation must be allowed to drain out Removing AC From Window x Turn AC off and disconnect power cord K Remove sash seal from between windows and unscrew Safety lock X Remove screws installed through frame Close slide side panels into frame Keeping a firm grip
3. an ENERGY STAR Partner Sharp Electronics has determined that this product AF Q60PX AF Q80PX meets the ENERGY STAR guidelines for energy efficient air conditioners To meet these guidelines air conditioners must be at least 10 more efficient than the minimum Federal standard FOR YOUR PROTECTION To aid in answering questions if you call for service or for reporting loss or theft please record below the model and serial number located on the right side of the unit MODEL NUMBER SERIAL NUMBER DATE OF PURCHASE Dealer Name Address City State Zip Telephone TO PHONE Dial 1 800 BE SHARP 237 4277 for SERVICE for your nearest Sharp Authorized Servicer PARTS for your Authorized Parts Distributor ACCESSORIES ADDITIONAL CUSTOMER INFORMATION TO WRITE For service problems warranty information missing items and other assistance Sharp Electronics Corporation Customer Assistance Center 1300 Naperville Drive Romeoville IL 60446 1091 Please provide the following information when you write or call model number serial number date of purchase your complete mailing address including zip code your daytime telephone number including area code and description of the problem CONSUMER LIMITED WARRANTY CONSUMER LIMITED WARRANTY SHARP ELECTRONICS CORPORATION warrants to the first consumer purchaser that this Sharp brand product the Product when shipped in its original container will be free from defective work
4. if using gas appliances GROUNDING INSTRUCTIONS WARNING Improper use of the grounding plug can result in the risk of electric shock This appliance must be grounded In the event of an electrical short circuit grounding reduces the risk of electric shock by providing an escape wire for the electric current This appliance is equipped with a cord having a grounding wire with a grounding plug The plug must be plugged into an outlet that is properly installed and grounded WARNING Do not under any circumstances cut or remove the round grounding prong from this plug If it is necessary to use an extension cord use only a UL Listed 3 wire extension cord that has a 3 blade grounding plug and a 3 slot receptacle that will accept the plug on the appliance The marked rating of the extension cord should be AC 125 Volt 15 Amp or more Consult a qualified electrician or serviceman if the grounding instructions are not completely under stood or if doubt exists as to whether the appliance is properly grounded If a grounding adapter is used make sure the receptacle box is fully grounded 3 Pronged receptacle Grounding adapter Grounded receptacle box Grounded receptacle box Grounding wire Screw Tab for grounding screw PRECAUTIONS NOTES ON OPERATION Allow 3 minutes for the compressor to restart cooling If you turn the air conditioner off and immediately restart it allow three minutes for the compressor to restart coo
5. on air conditioner raise sash and carefully rock air conditioner backward to drain any condensate water in base of unit Be careful not to spill any remaining water while lifting unit from window Store parts WITH air conditioner PRECAUTIONS CAUTION FOR USE IMPORTANT Points to keep in mind when using your air conditioner e Install the air conditioner by following the installation instructions given in the previous section of this manual e Make sure the unit is the correct capacity for the area you want to cool e Do not modify any part of this product e Do not insert objects into any part of the unit e Push the AC power plug securely into the receptacle and make sure it is not loose e Use power circuit with a proper voltage rating Use a three pronged grounded electrical outlet rated 125V 60Hz 15 amp or more AC only as shown on right Use of an improper voltage rating power circuit can result in damage to the unit and possibly fire 3 Pronged Grounding Receptacle 15 Amps 125V e Always use a fuse with the proper amp rating Do not under any circumstances use wire pins or other objects in place of the proper fuse e Use of extension cords of any kind is not recommended If you still elect to use an extension cord it is absolutely necessary that it be a UL Listed 3 wire grounding type appliance extension cord rated 125 Volts 15 amp or more e Ventilate the room periodically during use especially
6. warranties granted by Sharp and shall be the sole and exclusive remedy available to the purchaser Correction of defects in the manner and for the period of time described herein shall constitute complete fulfillment of all liabilities and responsibilities of Sharp to the purchaser with respect to the Product and shall constitute full satisfaction of all claims whether based on contract negligence strict liability or otherwise In no event shall Sharp be liable or in any way responsible for any damages or defects in the Product which were caused by repairs or attempted repairs performed by anyone other than an authorized servicer Nor shall Sharp be liable or in any way responsible for any incidental or consequential economic or property damage Some states do not allow the exclusion of incidental or consequential damages so the above exclusion may not apply to you THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS YOU MAY ALSO HAVE OTHER RIGHTS WHICH VARY FROM STATE TO STATE AF Q60PX AF Q80PX Room AirConditioner Be sure to have this information available when you need service for your Product Your Product Model Number amp Description Warranty Period for this Product One 1 year parts and labor from date of purchase The warranty period continues for a total of five 5 years from date of purchase for the Sealed Cooling System parts labor and service are not provided free of charge for this additional period Additional Item s Excl
7. ENERGY O COOL SAVER O TIMER FAN O ACTIVATES TIMER ess Tewe a SETS MODE ADJUSTS TEMPE RATURE OR TIME a TURNS UNIT ON OR OFF AUTO COOL FEATURE SETS FAN SPEED Touch Pad 11 HOW TO OPERATE Before you begin thoroughly familiarize yourself with the control panel and remote as shown below and all its functions then follow the symbol for the functions you desire The unit can be controlled by the touch pad alone or with the remote DISPLAYS TEMPERATURE TIM FAN SPEED cool O ENERGY O AUTO SAVER O cool O TIMER ACTIVATES TIMER SETS MODE ae ADJUSTS TEMPE RATURE OR TIME TURNS UNIT AUTO ON OR OFF Mode AUTO COOL FEATURE SETS FAN SETS FAN SPEED SPEED LOWERS j TEMPERATURE EE OR TIME TURNS UNIT ON OR OFF Cool FAN Mode ACTIVATES TIMER ENERGY SAVE MODE RAISES TEMPERATURE OR TIME SETS FAN SPEED Remote Control NOTE The following instructions represent the Touch Pad the same instructions can be used for the Remote Control TO TURN UNIT ON cool O ENERGY SAVER O AUTO O COOL Hr z Cc O TIMER TEMP TIMER DO THIS PRESS POWER ON OFF PAD 12 YOU WILL SEE AUTO O COOL O TIMER oy TEMP TIMER CS zZ coo O ENERGY SAVER O FAN HOW TO OPERATE TO CHANGE TEMPERATURE YOU WILL SEE SETTING coo O AUTO ENERGY Q DO THIS O COOL SAVER F coo O AUTO ENERGY O co
8. F 50 C or more when cleaning OILING OF THE COMPRESSOR AND FAN MOTOR IS UNNECESSARY The compressor is permanently lubricated and is hermetically sealed The fan motor is lifetime sealed and does not require oiling REMOVING THE AIR CONDITIONER Before removing the air conditioner operate the unit in the FAN mode with high fan speed ona dry day for about half a day to thoroughly dry the water inside the air conditioner unit 17 BEFORE CALLING FOR SERVICE IF YOUR AIR CONDITIONER DOES NOT OPERATE PROPERLY PLEASE CHECK THE FOLLOWING ITEMS BEFORE CALLING FOR SERVICE 18 POWER PLUG CHECK This air conditioner uses a fused power plug Always check the power plug before use 1 Press the RESET button 2 Insert the power plug into the wall socket 3 Press the TEST button You will hear a CLICK if the circuit breaker is functioning correctly 4 Press the RESET button until you hear another CLICK The circuit breaker is activated power is supplied and the air conditioner is now ready for use Do not attempt to use the air conditioner if the above procedure is impossible as it is malfunctioning Disconnect the power plug and request a service AIR CONDITIONER DOES NOT OPERATE AT ALL e Is the unit plugged in or is the plug loose e Is the fuse blown or the circuit breaker tripped e Did you restart the unit within 3 minutes after a power failure If the power was off for less than 3 minutes and you rest
9. SHARP FN ROOM AIR CONDITIONER AF Q60PX INSTALLATION AND OPERATION ENERGY STAR FOR YOUR PROTECTION sc00000 2 CONSUMER LIMITED WARRANTY 3 INSTALLATION INSTRUCTIONS CHECK WINDOW AREA 020000 4 LOCATION cae cacceotatrtiectsncntercsmecstaceneuasceces 4 ACCESSORIE G serrer p 5 6 SUGGESTED TOOLS anesrisinipreninois 9 INSTALLATION 00 ecccceeeeeeeeeeeeees 6 PRECAUTIONS CAUTION FOR USE indcreccancexenesvaciasnesss 9 e GROUNDING INSTRUCTIONS 9 NOTES ON OPERATION 10 ENERGY EFFICIENCY TIPS 10 HOW TO OPERATE PARTS NAMES cccccccceeeeeeeeeeeeeees 11 TO TURN UNIT ON eeeeeeeees 12 e TO CHANGE TEMPERATURE SETTING 13 TO ADJUST FAN SPEEDS 13 e TO USE AUTO COOL FEATURE 13 TO OPERATE ON FAN 0 ccceeee 14 e TO USE ENERGY SAVE FEATURE 14 TIMER FEATURE chcesidccerssieercevetarcnees 14 TO TURN UNIT OFF ae 15 This INSTALLATION AND OPERATION e TO CHANGE AIR FLOW DIRECTION 15 MANUAL explains the proper use of your new e USING THE REMOTE CONTROLLER 16 Sharp Air Conditioner Read these instructions CLEANING AND MAINTENANCE 17 carefully before installing or operating your air conditioner The INSTALLATION AND OP BEFORE CALLING FOR SERVICE 18 ERATION MANUAL should be kept in a safe FAULT CODES eee eee eee ee 1 9 place for handy reference As
10. arted the air conditioner within 3 minutes a protective device may cause the compressor to shut off preventing cooling for about 5 minutes AIR CONDITIONER DOES NOT PROPERLY COOL e Is the MODE set to fan only Mode Cooling will not take place in the fan only mode Change the MODE setting e s the filter clogged with dust A dirty filter can cause the cooling coils to freeze If this happens clean the filter and replace Run the airconditioner on the MED FAN setting until all ice dissipates e s the temperature set properly If your room is too warm adjust the temperature setting lower e s the window exposed to direct sunlight Close curtains or blinds to minimize solar energy heating the room e Are the windows or doors open Close all windows and doors for maximum cooling BEFORE CALLING FOR SERVICE NOTE WATER IN BOTTOM OF TRAY e Water will collect in the bottom tray of the unit This is normal Water condenses on the evaporator coil at the front of the unit and is channeled to the rear where it is picked up by the condenser fan The water is blown onto the condenser coil fins and this creates a splashing noise which is normal If excess water builds up in this tray it will drain outside through a grooved channel in the tray SOUNDS e The operating sound may seem rather loud for 2 to 3 minutes when the unit is first turned on This is the sound of the compressor s start up and is normal e A soft swishing noise can be hea
11. ed to direct sunlight or near a heater Protect the remote control from moisture and shock which can discolor or damage it CLEANING AND MAINTENANCE CLEANING THE FILTER If the filter is clogged with dust the amount of air flow will be reduced resulting in poor cooling performance The filter should be cleaned every 10 days At the beginning of every cooling season or after a long period of inactivity clean the filter before starting the unit REMOVE THE FILTER Open the front panel and get the filter out CLEAN THE FILTER To remove dust from the filter use a vacuum cleaner or wash it in clean water If the filter is very dirty wash it with detergent and rinse carefully with clean water Dry the filter with a soft cloth Do not expose the filter to heat or dry it in direct sunlight 3 RE INSTALL THE FILTER Put the filter into its original position and close the front panel Never operate the unit without installing the filter It may result in serious damage to the unit CLEANING OF THE FRONT PANEL AND CABINET To clean the front panel and cabinet wipe with a soft dry cloth or with a cloth moistened with a mild soap Rinse carefully by wiping with a damp cloth and dry completely Avoid splashing the unit with water Excess water can damage electrical insulation and result in danger Never use harsh chemicals or abrasive cleaners on any part of the unit To avoid damage to the unit do not use hot water 120
12. ght during cooling operation Keep the filter clean Keeping the filter clean greatly aids efficient operation A dirty filter blocks the flow of air making your air conditioner work harder and less efficiently See page 17 on how to clean the filter Turn off unnecessary lights Your air conditioner must remove the heat produced by your lights or other heat producing appliances Turn off lights or appliances that are not in use Install your air conditioner in a shady location Direct sunlight on a window air conditioner increases its workload and will increase its operating cost Don t let cool air escape Close windows and outside doors Do not keep doors open and let hot air rush in Improperly installed air conditioners and improperly weatherstripped doors and windows will let hot air in and the cool air out Turn off air conditioner when no one is home Use only when necessary The fewer hours a room air conditioner is used the lower the operating cost HOW TO OPERATE PARTS NAMES UNIT Control panel Air outlet Indoor Side Vertical louvers Horizontal louvers Cabinet Air outlet Outdoor Side Air inlet Outdoor Side Air filter Open the front panel to remove 9 Front panel 10 Air inlet Indoor side 11 Power cord Se ee ee CONTROL PANEL The display always shows the set temperature except when setting the Delay timer DISPLAYS TEMPERATURE TIME COOL FAN SPEED AUTO
13. ion To adjust timer setting tap or hold the UP arrow s or the DOWN arrow wy to change delay timer at 0 5 hour incre ments up to 10 hours then at 1 hour increments up to 24 hours The control will count down the time remaining until start 8 7 5 7 etc The Timer On mode automatically selects cooling with maximum Fan Speed The temperature maintained will be the same as previously set To change the set temperature press MODE then Up or Down arrows until the desired temperature is indicated on the display After 5 seconds the control will automatically change the display back to the hours remaining until the unit will start stop Turning the unit ON or OFF at any time will cancel the Timer On Off function The Timer On Off Feature will work until the unit either starts or stops Once that happens the above steps have to be repeated again HOW TO OPERATE TO TURN UNIT OFF coo O AUTO ENERGY O COOL SAVER O O TIMER r FAN O DO THIS PRESS POWER ON OFF The horizontal louvers are used to adjust the UP DOWN direction of air flow and the vertical louvers are used to adjust the LEFT RIGHT direction of air flow for uniform and efficient cooling of the room Vertical louvers Horizontal louvers Lever Adjust UP DOWN air flow Adjust LEFT RIGHT air flow 15 HOW TO OPERATE 16 USING THE REMOTE CONTROL INSTALLING BATTERIES Use two size AAA R03 bat
14. ling There is an electronic device in the unit that keeps the compressor off for three minutes 10 When power failure occurs This air conditioner has a memory function to store settings when a power failure occurs After power recovery the unit will automatically re start in the same settings which were active before the power failure Dehumidifying function The air conditioner removes moisture from the air in your room Cooling operation under low temperatures Is your unit freezing up The unit operates on inside and outside temperatures Freezing can occur when the temperature is set close to 64 F and when there are low outside temperatures especially during the night hours At these conditions a further temperature drop may cause the unit to freeze Setting the unit to a higher temperature will prevent it from freezing ENERGY EFFICIENCY TIPS Setting the proper temperature For optimum energy efficiency keep the difference between the inside and outside temperature within 10 F 5 C Do not keep the temperature setting any lower than is necessary for you to feel comfortable Generally 78 F to 80 F 26 C to 27 C is a comfortable summer indoor temperature When you turn the unit on do not set the temperature higher than the room temperature at start up as this will not allow the compressor to cycle and maintain a comfortable room temperature Avoid direct sunlight Close blinds drapes or shades to keep out direct sunli
15. manship and materials and agrees that it will at its option either repair the defect or replace the defective Product or part thereof with a new or remanufactured equivalent at no charge to the purchaser for parts or labor for the period s set forth below This warranty does not apply to any appearance items of the Product nor to the additional excluded item s set forth below nor to any Product the exterior of which has been damaged or defaced which has been subjected to improper voltage or other misuse abnormal service or handling or which has been altered or modified in design or construction In order to enforce the rights under this limited warranty the purchaser should follow the steps set forth below and provide proof of purchase to the servicer The limited warranty described herein is in addition to whatever implied warranties may be granted to purchasers by law ALL IMPLIED WARRANTIES INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR USE ARE LIMITED TO THE PERIOD S FROM THE DATE OF PURCHASE SET FORTH BELOW Some states do not allow limitations on how long an implied warranty lasts so the above limitation may not apply to you Neither the sales personnel of the seller nor any other person is authorized to make any warranties other than those described herein or to extend the duration of any warranties beyond the time period described herein on behalf of Sharp The warranties described herein shall be the sole and exclusive
16. material to prevent damage to the surface Remove backing from seal strip A Remove the backing from the top mounting rail seal strip and attach the seal strip to the bottom of the top mounting rail along the FRONT VIEW Top mounting rail front edge See FIG 1 A Seal strip FIG 1 B Align the holes in the top rail with those in top of the unit as shown in FIG 2A The higher flange should be toward the front of the air conditioner C Secure the top rail to the unit with 3 s 9 5mm Type B Screws as shown in FIG 2B INSTALLATION INSTRUCTIONS NOTE Top Rail and Sliding Panels at each side are offset to provide the proper pitch to the rear of the unit This is necessary for proper condensed water utilization and drainage If you are not using the Side Panels for any reason this pitch to the rear must be maintained There is a Left and Right Window Filler Panel be 3 sure to use the proper panel for each side When installed the flange for securing the panel to the window sill willbe facing into the room A Hold the Accordion Panel in one hand and gently pull back the panel beyond the ends of the frame See FIG 3 B Slide the left and right accordion panels into the top and bottom mounting rails See FIG 4 C Attach the accordion panels to the case using 3 1 4 6 5mm Type A screws on each side FIG 5A FIG 5B amp FIG 11 FIG 5A NOTE If storm window blocks AC
17. ol Ae SAVER O TIMER Hr FAN O TEMP TIMER AUTO POWER COOL FAN a O TIMER PRESS TO RAISE PRESS TO LOWER Note Tap or hold either up 4 or down W button until the desired temperature is seen on the display This tempera ture will be automatically maintained anywhere between 60 F 16 C and 90 F 32 C If you want the display to read the actual room temperature See To Operate on Fan section TO ADJUST FAN SPEEDS YOU WILL SEE DO THIS oF coo O coo O O Coo SAVER O PRESS TO coo SAVER O O TIMER FAN SELECT O TIMER Hr FAN FASTER TEMP TEMP TIMER TIMER PRESS TO SELECT a SLOWER Press the Fan Faster button s will increase the fan speed from Low LO to Medium ME to High HI The digital display will indicate your chosen speed Press the Fan Slower button W will decrease the fan speed from High Hl to Medium ME to Low LO The digital display will indicate your chosen speed After 5 seconds the display will revert back to the set temperature TO USE AUTO COOL YOU WILL SEE prea OF coo O P coo O AUTO ENERGY AUTO ENERGY O COOL SAVER O COOL SAVER O O TIMER O TIMER Hr FAN O DO THIS TEMP TIMER AUTO POWER Note Fan starts at High Speed and adjusts to a slower speed as the room temperature dictates For example if the room doesn t get too warm it will stay at the slowest speed If the room temperature rises quickly such a
18. rd immediately after the unit is turned on or off and also during operation This is the sound of the refrigerant flowing inside the unit IF THE UNIT FAILS TO RECEIVE THE REMOTE CONTROL SIGNAL e Check the remote control batteries Replace if necessary e Try to send the signal again with the remote control pointed directly at the unit s receiver window e Check whether the remote control batteries are installed with the polarities properly aligned FAULT CODES oF coo O AUTO ENERGY O coo FS SAVER O O TIMER Hr FAN O TEMP TIMER AUTO POWER COOL C FAN G If the display reads AS a sensor has failed Contact your Authorized SHARP Service Center 19 SHARP SHARP ELECTRONICS CORPORATION Sharp Plaza Mahwah New Jersey 07495 1163 SHARP CORPORATION Osaka Japan Printed in China 66121676
19. s a door being opened it will automatically go to the highest speed The fan speeds will re adjust back to the slowest speed as the room returns to the original set temperature Press either the fan slower W or fan faster button to adjust the fan speed manually 13 HOW TO OPERATE 14 TO OPERATE ON FAN YOU WILL SEE LIGHT ON oF coo O o te NEO DO THIS o te O TIMER Hr FAN O O TIMER PRESS MODE ATOE BUTTON O a CHOOSE Note Use this function only when cooling is not desired such as for room air circulation You can choose any fan speed you prefer During this function the display will show the actual room temperature not the set temperature as in the cooling mode TO USE THE ENERGY LIGHT ON SAVE YOU WILL SEE oF coo O DO THIS cool O O Coo m SAVER O O Coo SAVER O TIMER Hr FAN O O TIMER Hr FAN O PRESS MODE BUTTON tts a tts a CHOOSE ore a ore Note In this mode the fan will continue to run for 3 minutes after the compressor shuts off The fan then cycles on for 2 minutes at 10 minute intervals until the room temperature is above the set temperature at which time the compressor turns back on and cooling starts TIMER TIMER ON OFF YOU WILL SEE LIGHT ON coo O coo O AUTO ENERGY O ENERGY O O cool t SAVER DO TH S Mog SAVER TIMER O O o O O Note For Timer Off the unit must be in the On position Note For Timer On the unit must be in the Off posit
20. teries Battery E i compartment 1 Open the battery compartment cover cover Insert and slide the batteries into the compartment making sure the amp and polarities are properly aligned i J 3 Close the cover Slide out NOTES e The battery life is approximately one year with normal use e When you replace the batteries always use two new ones of the same type e f the remote control does not operate normally after replacing the batteries take out the batteries and replace them again after 30 seconds e f you will not be using the unit for a long time remove the batteries from the remote control HOW TO USE THE REMOTE CONTROL Point the remote control towards the unit s re ceiver window and press the desired button A beep will sound when the unit receives the signal e Make sure no objects such as curtains block the receiver window e The remote control operates from up to 20 feet 6 meters away e The beep will also sound when each pad on the control panel is touched CAUTION e Do not expose the receiver window to direct sunlight This can adversely affect its operation In such case close the curtains to block the sunlight e Use of a fluorescent lamp in the same room may interfere with the transmission of the signal e The unit may be affected by signals emitted from the remote control of a television VCR or other equipment used in the same room e Do not leave the remote control expos
21. uded From Appearance items of the Product remote control filter or accessories Warranty Coverage If any mounting kit seals or any printed materials Product which has been used for rental and or commercial purposes Where to Obtain Service From a Sharp Authorized Servicer located in the United States To find the location of the nearest Sharp Authorized Servicer call Sharp Toll Free at 1 800 BE SHARP What to Do to Obtain Service l l E l l Contact your Sharp Authorized Servicer to obtain in home service for this Product The Servicer will come to your home and if it is necessary to remove the Product the Servicer will reinstall it Be sure to have Proof of Purchase available TO OBTAIN SUPPLY ACCESSORY OR PRODUCT INFORMATION GO TO OUR WEBSITE AT www sharpusa com OR CALL 1 800 BE SHARP SHARP SHARP ELECTRONICS CORPORATION Sharp Plaza Mahwah New Jersey 07495 1163 INSTALLATION INSTRUCTIONS Before beginning installation read these instructions carefully Use the enclosed MOUNTING KIT for proper installation CHECK WINDOW AREA The mounting kit is designed for wooden sill double or single hung sash type windows Mounting kit fully closed Mounting kit fully opened 24 2 622mm 38 s 968mm Window opening from stool to lower sash bottom must be 13 346mm or more Lower sash bottom

Download Pdf Manuals

image

Related Search

Related Contents

  のご紹介 - NTT-ATテクノコミュニケーションズ株式会社  bilan traam 2012-2014 - Site des professeurs documentalistes de l    corega Fast SW1002/1802 取扱説明書  取扱説明  

Copyright © All rights reserved.
Failed to retrieve file