SECO-LARM USA SK-1123-FQ User's Manual
Contents
1. Refer to your alarm control panel manual to determine whether the arm disarm control is NC or NO e Set output Z2 to momentary mode for Terminals in Alarm Control Panel for Connecting Remote Arm Disarm Control Switch d multi station systems or ON OFF mode for single station systems See page ALARM CONTROL PANEL 14 section 3 for programming options e Use a 12VDC relay and connect it to the same 12V power supply as the keypad e Using this setup the owner may enter the user code for output 2 to disable output 1 during a certain period to prevent unauthorized access e Set output 2 to ON OFF mode pg 14 section 3 programming option 51 e Connect the O P 1 INHIB terminal with the O P 2 N O terminal as shown in wiring diagram User code 1 is invalid while the O P 1 INHIB terminal is shunted to ground via user code 22 WARNING e Make sure nobody is inside the house before starting the door lock inhibit function e heinhibit authorization code should always be kept by only the owner SECO LARM U S A Inc ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD WIRING Auxiliary Accessories 1 Tamper N C When the keypad is secured in the Tamper l O ALARM single gang box the tamper switch is in the NL CONTROL closed position When the keypad is PANEL l 1 removed the tamper switch will open 24 hour N C Connect the terminals to a 24 hour N C pr ee
2. p j io t 7 Output relay activated 1 sec long beep NOTE The buzzer can be disabled through programming option 83 see pg 14 section 8 The output relay activated beep can be disabled through programming option 81 see pg 14 section 6 Page 12 SECO LARM U S A Inc ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD SPECIFICATIONS Power e Operating voltage 12 24 Volts AC DC No jumper needed to set voltage e Stand by current drain 10mA 12VDC e Active current drain press keypad key Under 45mA 12VDC e Active current drain one relay activated Under 100mA 12VDC Outputs e Output 1 5A 30VDC max rating Form C dry contact NO COM NC Programmable for 1 to 999 second timed output or shunt ON OFF output Three terminals e Output 2 100mA 224VDC max rating Transistor ground output programmable for 1 to 999 second momentary output or shunt ON OFF output One terminal e Mantrap interlock control output 100mA 24VDC NPN open collector switches to ground for five seconds after relay output 1 is activated continues while the door is open Use to disable a second keypad during this time Single terminal e Duress output 100mA 24VDC NPN open collector switches to ground when active Single terminal Inputs e Power 12 24 Volts AC DC Two terminals e Egress N O ground Single terminal e Door sensor input N C grou
3. 1 Enter Programming Mode Enter Master Code Confirm Key in the Master Code For first time use Master code is o o o o 2 Data Refresh Note After entering programming mode proceed to desired programming option Function Enter into programming mode Option Confirm Function 9 0 Clears all previously stored data except for the master code 3 Configure Outputs DEFAULT Momentary 1 second output for both outputs Option Output Time Confirm Function 0 1 to 999 Output 1 momentary mode from 1 to 999 seconds Output 1 shunt mode ON OFF 0 1 to 999 Output 2 momentary mode from 1 to 999 seconds Output 2 shunt mode ON OFF Note Output time must be entered for options 40 and 50 4 Wrong Code Lockout DEFAULT 10 tries 30 seconds Option of Tries Confirm Function 0 After 10 successive wrong codes 30 second lockout After 10 successive wrong codes Duress activated After 5 to 10 wrong codes 15min lockout Can reset with Master Code No wrong code lockout 5 to 10 ellol o Note of tries must be entered for option 72 5 Door Forced Open Alarm Option Code Entry Confirm ss a 6 Door Unlocked Annunciation DEFAULT Disabled Function Door forced open alarm is enabled Door forced open alarm is disabled DEFAULT On Option Code Entry Confirm Function 1 second beep notifies the user to open the door when the output relay is activated with the user code or reque
4. Note User D must be entered for options 1 and 2 EXIT THE PROGRAMMING MODE BY PRESSING THE KEY Function Deletes specific user ID from output 1 Deletes specific user ID from output 2 SECO LARM U S A Inc Page 13 ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD PROGRAMMING NOTES 1 Master Code The SK 1123 FQ comes pre programmed with the Master Code set at 0000 Additional codes and or data should be programmed at the owner s discretion However to ensure security program a new Master Code to replace the factory set Master Code as soon as possible 2 Factory defaults Door forced open alarm Disabled 06 User code length 4 8 digits Door unlocked annunciation User code entry mode Output e Output 2 time Wrong code lockout 10 tries 30 sec Door forced open alarm Disabled Keypress beep Door propped open alarm Silent operation 3 Code operation User codes are each four to eight digits and are assigned a two digit ID If all the codes have the same number of digits the keypad can be programmed for auto code checking The key need not be pressed after entering a code see programming option 82 page 14 section 7 The administrator can easily delete the code of a single user via the two digit ID if the user is no longer authorized to enter a protected area Relay output 1 allows up to 100 user codes and output 2 allows up to 10 user codes 4 Using Duress codes relay output 1 only Duress c
5. longer has authority to enter the protected area 1 Enter program mode by keying in the master code and the key The keypad is now in the programming mode 2 Enter the output user ID number and the key To delete user ID 05 from output 1 press 1 0 To delete user ID 1 from output 2 press 3 Exitthe programming mode by pressing the key MASTER CODE ByPAss DAP JUMPER If the master code has been forgotten or does not work use the DAP direct access to program jumper to override the forgotten code and permit direct entry into the programming mode as follows 1 Disconnect the power supply 2 Move the DAP jumper from OFF to ON 3 Reconnect the power supply The keypad will start beeping 4 Move the DAP jumper back to the OFF position The keypad will stop beeping as soon as the jumper is removed 5 Key in anew master code as follows ption Key in New Code Confirm Exit 0 Zero 0 is for new master code only see page 13 and 14 for other options Note DAP reset does not change any previously configured settings DAP will only give direct access to programming by bypassing the master code requirement SECO LARM U S A Inc Page 15 ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD INSTALLER PROGRAMMING These functions should only be used by professional installers as incorrect entries can disable the entire keypad function DEFAULT 0 o o o
6. ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD QuicK REFERENCE GUIDE 1 Using the User Codes A User codes operate the door 4 8 digits long Press B The key must be pressed also if the keypad is in manual entry mode Press uJ u u u Using the Master Code The Master Code can be used to operate the door or program the keypad 4 8 digits long see section 5 below Press Output 1 Press Output 2 Note indicates user code Note indicates master code NO C2 Using the Inhibit Lockout Code Please contact your installer for an explanation of inhibit mode and its operation A Using Duress Codes For a full explanation of duress codes and their uses see pg 12 Cc Delete Add Change User and Master Code WARNING Press the correct option key If the option key is not used and a 0 is pressed after entering the Master Code it could accidentally reprogram the Master Code A Enter the Master Code first followed by the key If you forgot the master code see page 15 for more information Press B Changing Adding Users Press 00 99 user ID user code 4 8 digits for output 1 Press 0 9 user ID user code 4 8 digits for output 2 C Deleting Individual Users Press 1 00 99 user ID for output 1 Press 2 0 9 user ID for output 2 D Changing the Master Code Press 0 Where is the new master code E To exit programming mode press the
7. S 5 8 15mm PARTS LIST a 123 39 C Keypad x 1 ooo amp Diode x 1 mE Security screw x 2 Security wrench x 1 43 120mm d lt 31 80mm gt L im E mm Page 2 SECO LARM U S A Inc ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD REPROGRAM THE KEYPAD SELECT DATA To change certain data in the keypad such as to delete or change user codes do the following 1 Enter programming mode by keying in the master code and the key The keypad is now in the programming mode 2 Use the programming instructions on page 13 and 14 to make desired changes to the keypad s data 3 Exit the programming mode by pressing the key REPROGRAM THE KEYPAD COMPLETE DATA REFRESH Sometimes it may be necessary to completely erase all current data except the master code and input new data An example of when this may be necessary is the sale of a protected building to a new owner In such a situation do the following 1 Enter the programming mode by keying in the master code and the key then enter the refresh code 9 o and the f key The keypad is now in the programming mode 9 o All old data is cleared and the keypad is ready for new data Note The master code does NOT change 2 Use the programming instructions on pages 13 and 14 to enter the keypad s data 3 Exit the programming mode by pressing the key DELETE USER To delete a user who no
8. ads can protect an area with two doors by ensuring that only one door can be opened at a time With the mantrap function enabled when a user opens one door a signal is sent to disable the second keypad thereby preventing access through the second door until the first one is closed e Output 1 inhibit control Relay output 1 is typically used for a door strike If the inhibit control terminal is tied to ground relay output 1 will not operate This increases the security of the protected premises during the time it is not expected to be occupied such as during evening or weekend hours Control either by connecting output 2 or another switching device to the inhibit control terminal see example on page 6 e Door forced open warning When used with an optional magnetic contact the keypad will beep continuously for 60 seconds if the door to the protected premises is forced open without using a valid user code The warning can be stopped any time by entering a valid code e Door propped open warning When used with an optional magnetic contact the keypad beeps continuously if the door is propped open for longer than the allowed open time The allowable open time is programmable from 1 999 seconds The warning stops when the door is reclosed e Door hold open mode Output 2 can be programmed to hold the door open if it needs to remain open for an extended length of time e Auto or manual code entry checking e Auto code entry ch
9. alarm system protection zone if required 2 Door Sensing Door a Auto Relock The door will relock after ore a granting access to prevent tailgate entries CONTACT b Forced Open Alarm Alarm will go off N C instantly if the door is forced open Enable this function with programming option 801 found on pg 14 c Door Propped Open Alarm Alarm will go off if the door is left open longer than the programmed delay time Enable this function with programming option 9 1 999 seconds d Mantrap Interlock Control When the door is open the interlock output of the keypad will switch to ground to disable the MAGNETIC DOOR other keypads 3 Duress Output 12V Duress p EJ Duress zd ere Berrig Output F Law PANEL Exo OR lt piezo 24 hour N O buzzer protection zone max 100mA s oom unl When a duress code is entered the duress output will switch to ground It can trigger a connected LED lamp or small buzzer to notify a guard or connect it to a 24 hour N O alarm system protection zone NOTE Only one connection option is recommended Output current must not exceed 100mA SECO LARM U S A Inc Page 11 ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD WIRING Example Wiring 2 Keypads with Mantrap Interlock Diode 1N4004 Cathode Electric Lock 1 Egress button Open door 2 from inside Diode 1N4004 Cathode Mantr
10. ap Interlock Each keypad can be used as a stand alone keypad The mantrap feature is for a protected area with two doors to ensure only one door can be opened at a time With the mantrap feature enabled when a user opens one door either by entering a code or with a request to exit button a signal is sent to the second keypad to disable it thereby preventing access through the second door until the first door is closed e Usean N C magnetic contact or some other N C device to detect whether a door is opened or closed Do this for the two doors being protected e Combine this wiring diagram with the diagram on page if connection to an alarm control panel Is required e To use the mantrap feature o Use either the keypad from outside or the egress button from inside the protected premises to open one of the two doors o While the first door is opened the first keypad sends a signal to the second keypad to prevent the second door from being opened Door 22 sensing SM 200 a SIS Crosswire connection for interlock functions ground NN 4 Door 2 sensing N O SM 200 Egress button Open door 2 from inside o Once the first door is closed both doors are ready to open again Page 10 SECO LARM U S A Inc ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD 5 Door Hold Open Mode e For N C locking devices Connect a relay e For N O locking devices Connect a relay to to output 2 in series wit
11. aphical errors Copyright 2009 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the written permission of SECO LARM SECO LARM U s Inc 16482 Millikan Avenue Irvine CA 92606 Website www seco larm com E cu Tel 800 662 0800 949 261 2999 Fax 949 261 7326 E mail sales seco larm com mi SK 1123 FQ docx Page 16 SL SECO LARM MANUAL Flush Mount Outdoor Access Keypad SK 1123 FQ Also available from SECO LARM Indoor Keypads Outdoor Keypads _ yp a u yp 007 i x Eu Iz 755 IXY x75 9K 1123 5Q SK 2123 5Q SK 3123 8Q Ce e 9K 1011 5Q SK 1131 SQ ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD TABLE OF CONTENTS litle Uc oe i ne een eer en 2 POURS IVS UO cca ibl in itemm wetted A EMEN EEUU MM 2 Ungues arcs 110 NETTE e OTT 3 Vnd s Basic AG CAN essen crest at PUE mUNI ere EDU NU ID UR DE QERMEI Gn DNI 4 SDBCIICAIOl e un rated emma Mme EM MEM UE MM 5 Output 2 NPN Transistor Open CollectOr c ccccssssseesssesscssssssssescsseecsssseecesseeecsssceeseseesesseesaseeeeses 6 7 Wiring Example with Connection to Lock Device and Alarm Arm Disarm T User Ee ATI INE ETET T m 8 9 Wiring 2 Keypads with Mantrap Interlock esses 10 Wiring Auxiliary Accessories E 11 Programming Notes ccceccsscsssc
12. ecking mode The keypad can be programmed to activate automatically when the code is entered without the need to press the key All user codes must be the same length as the master code This mode is more convenient for users e Manual code entry checking mode The user codes can vary in number of digits and the user must press the key when finished entering the code This mode increases security e Door auto relock anti tailgating The keypad will relock an open door either when the relock time expires or immediately after the door is closed depending on which occurs first This prevents unwanted tailgate entries which can happen if an unauthorized person tries to follow an authorized person through the door e Alarm system arm disarm control The keypad can be wired to an alarm control panel so that an authorized user can arm or disarm an alarm system using the keypad e Duress output This NPN transistor open collector ground output can be used to trigger a silent alarm if an authorized user is forced under duress to use the keypad The duress output is activated by adding 2 to the first digit of any user code for output 1 When entered the code opens the protected door as it would normally but a signal is quietly sent to a remote device to call for help without alerting the unauthorized person e Backlit keypad The keypad is backlit to increase nighttime visibility Backlight can be programmed to remai
13. h the locking device output 2 in parallel with the locking device on woo oN L1fidinO 12 24V AC DC Power Supply Electric Lock 12 24V ACIDC Power Supply ALARM CONTROL PANEL Duress To 24 hour N O zone Com gnd of keypad amp alarm system Tamper To a 24 hour N C N C zone N O Egress button Open door from inside Note Additional egress buttons can be connected in parallel For DC use only e Connect the duress output to a 24 hour N O zone and the tamper output to a 24 hour N C zone on the alarm control panel e The keypad s terminal ground connects to the ground wire of the alarm control panel to enable the two to work together SECO LARM U S A Inc Page 7 Suomej ejsul INOA JO asn 0 jeeus siu Ado e oN 440 powwebold 90q ugof 31d vs soos AeJUSWOW JUNYS 3ndino Z Indjno Mm q P O e SS he a oq uyor 3idivs Jo4 powweibolg soos iejueuiloJA qjunus 3ndino 4 3ndino Aejey Hey apo 1as 0HE amp P I I5 Page 9 Page 8
14. key LIFETIME LIMITED WARRANTY This SECO LARM product is warranted against defects in material and workmanship while used in normal service for the lifetime of the product SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to repair or replacement only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damages of any kind to the purchaser or anyone else This lifetime limited warranty is for products sold and installed in the United States and Canada For all other countries the warranty is 1 one year NOTICE The information and specifications printed in this manual are current at the time of publication However the SECO LARM policy is one of continual development and improvement For this reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typogr
15. n off until all keys are pressed or remain on at a dim setting increasing to full brightness when keys are pressed SECO LARM U S A Inc Page 3 ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD WIRING BASIC DIAGRAM The ENFORCER SK 1123 FQ has backlit keys that can be programmed for different applications The keypad can be always illuminated FULL or illuminated only during user activity AUTO To verify or change the settings refer to the table below Back lit jumper FULL AUTO 1 3 BACK LIT UMPER z5 DAP Jumper Interlock NPN transistor used N C tamper with second keypad N C tamper 9 N O Output 1 inhibit m aT 12 24N oz N C Door position sensor Se Roca Common ground for use VACIVDC 2 with interlock function m z 2 e g N C E d Egress N O ground 4 9 a 5 Duress output Transistor Output 1 COM ground 100mA 24VDC z ao o 6 z N O a N O output 2 TAMPER Back Lit Jumper Setting Jumper Position Description e Keypad standby mode is dimly backlit FULL e Keypad brightens to full illumination for 10 seconds default after each key is pressed then returns to dim backlit standby mode e Keypad standby mode is not lit e Keypad brightens to full illumination for 10 seconds after each key is pressed then turns off again standby mode For DC connect to a regulated power supply Polarity of the regulated power supply must be correct F
16. nd Connect to an N C magnetic contact to show if door is opened or closed or connect to ground if not used Single terminal e Relay output 1 disable input Connect to ground to prevent relay output 1 from operating or to the mantrap interlock control output of another keypad to disable output 1 while the other keypad is active Single terminal Other Features e Tamper 50mA max N C dry contact Connect to the tamper circuit of alarm control panel Two terminals e Common ground Code Operation e Auto or manual code entry Up to 100 user codes for output 1 up to 10 user codes for output 2 Over 100 million possible user code combinations Auto Reset Time During Code Entry e Max 10 seconds to enter each digit e Max 30 seconds to enter each code Dimensions 43 4 x31 8 x1 15 16 120x80x46 mm Weight 11 oz 300g SECO LARM U S A Inc Page 5 ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD OUTPUT 2 NPN TRANSISTOR OPEN COLLECTOR The Output 2 is an NPN transistor open collector output controlled by User Code 2 and can be used for some auxiliary controls It is equivalent to an N O output rated 100mA 24VDC 1 Shunting an N C Protection Zone TO ALARM CONTROL PANEL PROTECTION ZONE e Use output 2 to shunt an N C protection zone e Set output 2 to ON OFF Mode See pg 14 section 3 programming option 51 p
17. ns for MASTER CODE BYPASS DAP jumper Once the master code is set review the programming options and decide exactly what the keypad will do including the format of the user access codes as well as how the keypad responds via the relay output buzzer and LEDs Note that in every case the basic steps for programming are 1 Enter the master code followed by the key which puts you in programming mode 2 Enter the programming options defined in the various sections as needed followed by the key 3 Enter the key again to exit programming mode Note A rapid string of 5 beeps and or 5 LED flashes indicates an error while 2 beeps indicates that the entry has been accepted USER PROGRAMMING ENTER PROGRAMMING MODE Enter Master Code Confirm Function ADDING OR CHANGING MASTER AND USER CODES WARNING Press the correct option key If the option key is not used and a 0 is pressed after entering the Master Code it could accidentally reprogram the Master Code Enter into programming mode Option User ID Access Code Confirm Function 0 4 to 8 digits Change Master Code 00 to 99 4 to 8 digits Set change up to 100 User Codes for output 1 with duress feature 0 to 9 4 to 8 digits Set change up to 10 User Codes for output 2 Note User D must be entered for options 1 and 2 DELETE A USER To delete a user who no longer has authority to enter the protected area Option User ID Confirm 00 to 99 0 to 9
18. odes are used to activate a separate device silently to alert a guard or other personnel that a user is operating the keypad under threat The keypad operates as normal but a silent signal is sent to alert others Duress codes do not need to be programmed All user codes are automatically turned into duress codes by increasing the first digit of a user code by the number 2 The code is entered the same way as a regular user code For example User code 4468 can be entered as duress code 6468 User code 9843 can be entered as duress code 1843 User code 8181 can be entered as duress code 0181 NOTE If a user code is programmed its duress code is unique and cannot be programmed as another user code For example If user code 4468 is programmed its duress code of 6468 is automatically programmed A user code of 6468 cannot be programmed Note Once activated the duress output continues until a correct user code is entered LED INDICATORS e Red LED Illuminates while output 2 is activated e Amber LED Flashes to show the keypad status see below e Green LED Illuminates while output 1 is activated BUZZERS AND LED SiGNALS STATUS BUZZER TONES AMBER LED FLASHES Red Amber Green hmmm fo ra 2 Successful key entry 1 flash Qm 3 Successful code entry 2 flashes oe 4 Unsuccessful code entry 5 flashes fs 5 DAP jumper not replaced Continuous beeps pools ies 6 In standby mode L 1 flash in 2 sec intervals
19. or AC polarity is not important 2Mantrap control output Outputs ground for five seconds after relay output 1 is activated continues while the door is open 3Connect to ground to prevent relay output 1 from operating or to the mantrap interlock control output of another keypad to disable output 1 while the other keypad is active 4Connect to optional N O push button or switch Page 4 SECO LARM U S A Inc ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD PREPARING TO PROGRAM THE KEYPAD To program the SK 1123 FQ first determine the following information 1 The master code Allows the system administrator to program or operate the keypad 2 The user code or codes Allows users to use the keypad s functions Use the chart on pages 8 and 9 to organize 3 Configuration of the relays and outputs For relay output 1 and output 2 determine whether the output should operate from 1 to 999 seconds and then turn OFF momentary mode or turn ON OFF via the code shunt mode Use the chart on pages 8 and 9 to organize 4 Result of improper code entry optional Choose between a 30 second code lockout duress output a 15 minute code lockout or no reaction Note When appears in the instructions it indicates master code entry GETTING STARTED A master code is required to program the keypad The default master code is set to 0000 To change a forgotten master code go to page 15 and follow the instructio
20. sscssssccsssesessccesecessesaesessesessecessesaeesacesaesesacessesaseesatersaesatersaseesasersates 12 BB NMC AU ONS RENE E E cede cece a aicecect sates E E E E 12 Preparing t0 Progro et en ate ee een See ere eee eee eee 13 Getting Started ME NER 13 User Programing essees nese ERR EE DUUM E 13 Steet te OCI ANIMA S EE E E E EA E E T A AE E EEA 14 Reprogram the Keypad Select Data nennen 15 Reprogram the Keypad Complete Data Refresh c ccccssessesssescsssssssssescsssseteeseeesasersesaseees 15 ES U Se e 15 Master Code Bypass DAP jumper 15 ONCE Celie e SUIS assets eet nent eee ee eee eee DE MIND tede 16 INTRODUCTION The SK 1123 FQ is the ideal keypad for office commercial and home security installations This self contained security keypad has a built in 5 Amp relay output and a 100mA transistor ground output for maximum flexibility when connecting to electronic door strikes door alarms door chimes alarm control panels or other security and access control applications The outputs can be programmed for timed 1 999 seconds or ON OFF operation The SK 1123 FQ can be programmed for up to 100 4 digit to 8 digit user codes for the primary output and up to 10 4 digit to 8 digit user codes for the secondary output All programming and code information is stored in non volatile EEPROM memory to protect the data in case of power loss DIMENSION
21. st to exit button Use with a locking device that gives no sound when it activates such as a magnetic lock o The beep is disabled replaced by 2 short beeps for valid user codes 7 User Code Entry Mode DEFAULT Manual Option Code Entry Confirm Function Auto Entry Mode is selected The key that follows the user code is NOT required in code entry All User Codes MUST be set to the same digit length as the Master Code from 4 8 digits 9 Manual Entry Mode is selected The key that follows the user code is required in code entry The User Codes can be any length between 4 8 digits 8 Keypress Beeps DEFAULT On Option Code Entry Confirm Function Keypad beeps when a key is pressed aa 1 o Silent operation keypad does not beep when a key is pressed unless in programming mode 9 Door Propped Open Alarm Timer DEFAULT Off Option Seconds Confirm Function 0 No door propped open alarm 9 1 to 999 Allowable time from 1 to 999 seconds that the door can be left open before the door propped open alarm starts Note Allowable time must be entered 10 Exit Programming Mode Confirm Function Exits programming mode returns keypad to normal operation Page 14 SECO LARM U S A Inc ENFORCER FLUSH MOUNT OUTDOOR ACCESS KEYPAD UNIQUE FEATURES e 12 24V AC DC universal power No programming or jumpers needed e Mantrap Interlock When used in pairs and with optional magnetic contacts keyp