Home
SECO-LARM USA ENFORCER ST-2406-10AQ User's Manual
Contents
1. ST UV24 W50Q ST UVDA W100Q ST UVDA W180Q ST UV28 T350Q 24VDC N A 24VAC 50VA 24 28VAC 100VA 24 28VAC 180VA 24 28VAC 210VA 28VAC 350VA Table 2 Table 3 To program DC voltage output LED status for ST 2406 series ON Pie OFF OF OFF ON OFF For ST 1206 1 5AQ model See point 2 under Installation OFF OFF NOTICE The information and specifications printed in this manual are current at the time of publication However the SECO LARM policy is one of continual development and improvement For this reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typographical errors Copyright 2008 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the written permission of SECO LARM WARRANTY This SECO LARM product is warranted against defects in material and workmanship while used in normal service for a period of one 1 year from the date of sale to the original consumer customer SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not oper
2. Installation Manual ENFORCER 5 series Power Supplies Chargers Features e Automatic recharging of back up batteries e Several models to choose from e Programmable DC voltage output e Built in battery short circuit protection ST 2406 2AQ shown e Fused output for a regulated charge e Automatic switch over to the backup battery if main power is lost or cut e LEDs indicate power status e Includes foam tape and battery leads for easy installation e Regulated and filtered output voltage What it is SECO LARM s ST series of power supplies chargers ensure that alarm systems and access control systems always have enough power to do their job Protected by fused output input polarity protection diodes and back up battery polarity reverse protection these power supplies chargers can be used to maximize the security and efficiency of nearly any alarm or access control installation 6 12 24 6V 180mA 12 V 350mA 24 V 700mA 334 X 27k X 1 he 95x73x40 mm ST 2406 7AQ 6 12 24 6V 180mA 12 V 350mA 24 V 700mA 514 x516 x 214 140x130 x 55 mm ST 2406 10AQ 6 12 24 10 0A 6V 180mA 12 V 350mA 24 V 700mA 514 x 514 x 22a 140x 130x55 mm Fused Output The ST 1206 1 5AQ comes with a 3A fuse The ST 2406 2AQ ST 2406 3AQ and ST 2406 5AQ models come with a 5A fuse The ST 2406 7AQ and ST 2406 10AQ come with a 10A fuse Use only the correct fuses to prevent short circuits and damage to the power s
3. ating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damages of any kind to the purchaser or anyone else SECO LARM U S A Inc 16842 Millikan Avenue Irvine CA 92606 Website www seco larm com path eine ce er Tel 800 662 0800 949 261 2999 Fax 949 261 7326 E mail sales seco larm com ae ers
4. tputs lt gt To alarm or access control panel VDC negative input To Class II transformer To back up battery positive input VAC outputs To back up battery negative input To alarm or access lt gt To alarm or access control control panel VDC panel VDC negative input positive input 3 Connect the wirings to their respective terminals see Figure 1 and 2 NOTE a Before connecting any external devices temporarily power up the unit and measure the DC output voltage to avoid damage to devices Then disconnect power before connecting external devices b LED status for ST 1206 1 5AQ Red LED on indicates connections to AC power for ST 2406 series see Table 3 WARNING 1 Using a higher AC input than recommended may damage the unit 2 When a power supply charger is used at its maximum load for an extended period of time the heatsink portion of the power supply charger will be very hot 3 DO NOT USE METAL SPACERS TO MOUNT THE POWER SUPPLY S PC BOARD 4 Measure DC output before connecting devices Table 1 Transformer selection table Output voltage ST 1206 1 5AQ ST 2406 2AQ ST 2406 3AQ ST 2406 5AQ ST 2406 7AQ ST 2406 10AQ 6VDC 12VAC 20VA 12VAC 20VA ST UV24 W50Q ST UV16 W100Q ST UVDA W180Q ST UVDA W180Q 24VAC 50VA 16VAC 100VA 24 28VAC 180VA 24 28VAC 180VA ST UVDA W100Q ST UV16 W100Q ST UVDA W180Q ST UVDA W180Q eve i Oreo 24 28VAC 100VA 16VAC 100VA 24 28VAC 180VA 24 28VAC 180VA
5. upplies chargers or the alarm access control panel WARNING Connect these power supplies chargers only to a rechargeable back up battery Use of a non rechargeable back up battery could result in damage to the power supplies chargers or the alarm access control panel as well as leakage or explosion of the battery Installation 1 Mount the PC board in the desired location or enclosure It must be easily accessible for future servicing 2 DC Power Output Setting a To program ST 1206 1 5AQ DC voltage output 1 6VDC Cut the wire loop and connect to a 12VAC 20VA transformer INSULATE THE CUT WIRE LEADS so that they do not come in contact with the power supplies chargers 2 12VDC Leave the wire loop uncut and connect to a 16VAC 40VA transformer b To program ST 2406 Series DC voltage output 1 Set the desired DC output voltage 6 12 or 24 VDC of the power supply using the DIP switch See Table 2 2 The default voltage output setting is 12 VDC AN C RoHS WY Note Products with model number that ends with Q or have a green Q sticker represents RoHS compliant products Figure 1 ST 1206 1 5AQ wiring diagram Figure 2 ST 2406 Series wiring diagram To back up battery negative input To back up battery positive input Wire loop Red Led Green AC Input LED Red DC Output LED indicator SS To Class ll To alarm or access control B transformer panel VDC positive input 7 a 8 VAC ou
Download Pdf Manuals
Related Search
Related Contents
Koblenz 0011106 Use and Care Manual Ewent EW1622 PVM-20L5* PVM-14L5* - BroadcastStore.com Please read this manual carefully before operating fiche de renseignements pour l`organisation d`un 取扱説明書 - 日立の家電品 Laminat - Horn Bordplader DHIS 2 Android User Manual Copyright © All rights reserved.
Failed to retrieve file