1. 2 Dismount the armature plate from the bracket Warning Failure to remove the armature plate from the bracket will damage the armature and rubber washer Weld the armature bracket with 3 or 4 beads about 1 apart Make sure not to weld near the set screw hole See mounting diagram for No Weld areas 3 Remount the armature a Put one rubber washer between two steel washers and place them over the armature screw between the armature and the bracket This will allow the armature to pivot slightly around the armature screw in order to compensate for gate misalignment b Make sure the guide pins are inserted into guide holes to prevent the armature from spinning c Do not overly tighten the armature against the bracket The armature must be able to pivot around the armature screw D Run the wires The goal is to keep as little of the wires exposed as possible 1 Run the wires into an out of sight location as close as possible to the electromagnet 2 Use standard armored cable to prevent the wires from being cut between the electromagnet and the out of sight location E Connect the wires Note Unit is prewired for 12V operation See Wiring Diagram below for more information 1 For 12V operation Connect the red and white wires to 12VDC and the black and green wires to ground 2 For 24V operation Connect the red wire to 24VDC the green wire to ground and then tie the white and black wires together and insulate IMPORTAN
2. Positive Pressure Fire Tests of Door Assemblies for swinging door assemblies It is also classified in accordance with the Uniform Building Code standard 7 2 WARRANTY This SECo LARM product is warranted against defects in material and workmanship while used in normal service for a period of one 1 year from the date of sale to the original consumer customer SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for any special collateral incidental or consequential personal or property damages of any kind to the purchaser or anyone else NOTICE The information and specifications printed in this manual are current at the time of publication However the SECO LARM policy is one of continual development and improvement For this reason SECO LARM reserves the right to change specifications without notice S
3. ECO LARM is also not responsible for misprints or typographical errors Copyright 2007 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the written permission of SECO LARM FILE DT DTP IM_E 942FC xxxS pmd ORDER PART 764 024 _077 aif PITSW SECO LARM U S A Inc 16842 Millikan Avenue Irvine CA 92606 Website www seco larm com Tel 800 662 0800 949 261 2999 Fax 949 261 7326 E mail sales seco larm com Page 4 SECO LARM U S A Inc Installation Manual ENFORCER E 942FC 1K350 E 942FC 6005S0 Electromagnetic Lock with Weldable Brackets for Gates E 942FC 1K3SQ Shown e For most types of outdoor sliding and swinging electric gates e Includes a magnetic lock with brackets for armature and magnet KI e Brackets can be welded or bolted directly to gate RWHS e Holding force E 942FC 1K3SQ 1 300 pounds 591kg ee E 942FC 600SQ 600 pounds 272kg e Brackets are zinc plated for corrosion resistance e Brackets have black finish to match most gates e Water and vandal resistant attractive stainless steel finish e Maintenance free factory sealed design e Fail safe operation unlocks door if power is removed e Mounted vertically Four knockouts on the junction box e Adapter and mounting hardware included e Voltage 12VDC or 24VDC Prewired for 12VDC operation e Current draw 500mA 12VDC 250mA 24VDC CE
4. EVA M5521 3 length of bolt as necessary 4x Anti tamper caps 2 x Guide pins 1 x Security screw 1 x Allen wrench for junction box 1x AC pigtail connector 1x EVA M5521 3 DC pigtail connector 2 x Wire connectors 1 x Power Supply Power Supply Input 100 240 VAC 50 60Hz Output 12VDC 1 0A Page 3
5. Magnetic Gate Lock Bracket Installation Manual a TROUBLESHOOTING Problem Possible cause Solutions Gate does not lock No power e Check to make sure the wires are secure e Check that the power supply is connected and operating e Make sure the unit is wired correctly Poor contact between electromagnet and armature plate Gate locks but can be easily forced open e Make sure the electromagnet and armature plate are properly aligned e Make sure the contact surfaces of the electromagnet and armature plate are clean and free from rust Incorrect voltage setting e Check the power leads with a meter and make sure the correct voltage is present A secondary diode was The electromagnet is fitted with a metal installed across the oxide varistor to prevent interference so do electromagnet not install a secondary diode REGULAR MAINTENANCE e Clean the contact surfaces of the electromagnet or armature plate with a soft cloth and non abrasive non corrosive cleaner Apply a light coat of a silicon lubricant to both contact surfaces and wipe away the excess to prevent rust e Check that the armature plate is securely attached to the bracket yet can pivot slightly around the armature screw e Check that the electromagnet is securely attached to the bracket Delay in gate releasing UL CERTIFICATION Electromagnetic lock only Model E 942FC 1300 E 942FC 600 conforms to UL 10B Fire Tests of Door Assemblies and UL 10C
6. T Damage caused by improper connection will void warranty F Test the unit G Insert the tamper caps into the mounting screw access holes of the electromagnet This should be the last step as once the tamper caps are in place they are difficult to remove Wiring Diagram Control device such as push button switch keypad card reader etc Prewired 12VDC Red EAZVOC Green Note AC pigtail connector is included with the E 942FC 1K3SQ E 942FC 600SQ for those applications where needed Page 2 SECO LARM U S A Inc Magnetic Gate Lock Bracket Installation Manual Mounting Diagram Maglock Bracket Electromagnet Anti Tamper Armature Plate Mounting Armature f 7 Caps x 2 co Bolts Bracket Ma on ioptional oe me 7 m Eann aTa Mounting R Screws x 2 Rubber an Washer A Mounting fo fo a No Bolts Ce Weld optional Area Large Steel Washers Mounting aD SCreWS X 2 jee om 0g A Guide optional Secunty Anti Tamper optiona ecur No s Caps x 2 Pin Screw Wald Junction Bax Area Screws x 4 a Junction Box List of Parts Optional Parts 1 x Maglock bracket 1 x Armature bracket USER UE seetromagnet 3 8 Flat Socket Cap Mounting Screw 1 x Armature plate Aa Note Use in those applications 1x Armature screw where Armature Bracket and 2 x Large steel washers y Maglock Bracket will be bolted to 1x Rubber washer Iemen EOE ENE gate fence and not welded Cut 4x Mounting screws
7. us LISTED Magnetic lock only MOUNTING THE ELECTROMAGNETIC LOCK A Determine type of gate 1 Single swing gate Gate swings on one end and comes to rest on a fixed gate post when closed In this case a typical installation has the electromagnet fixed to the gate post and the armature connected to the free end of the gate 2 Double swing gate Two gates swing in the same direction when activated The electromagnet is fixed to the free end of one gate and the armature is fixed to the free end of the other 3 Sliding gate The gate slides instead of swings away from a fixed gate post A typical installation has the electromagnet fixed to the gate post and armature connected to the free end of the gate B Mount the electromagnet In most cases the position of the electromagnet will determine the location of the armature plate Make sure there is space to run the cable 1 Tack weld bracket into place Tack weld only 2 Dismount the electromagnetic lock from the bracket Warning Failure to remove electromagnetic lock will result in severe damage to lock Weld 3 or 4 beads about 1 apart Make sure not to weld the junction box See diagram for No Weld areas 3 Remount the electromagnetic lock Page 1 Magnetic Gate Lock Bracket Installation Manual ST C Mount the armature 1 Once the electromagnet is mounted determine the armature bracket location and tack weld into place Tack weld only
Download Pdf Manuals
Related Search
Related Contents
electronic chair scale fauteuil de pesée Nivo5.SCL - ニコン・トリンブル Tripp Lite 2-Prong European Computer Power Cord (C5 to SCHUKO CEE 7/7), 6-ft. Entwicklungsmethodik für SPS-gesteuerte - ETH E SUPER ® 平成23年3回定例会 (10月5日) Weatherables PKPR-T&G-6X8 Instructions / Assembly Philips VSS9900 User's Manual Manuale Uso e Manutenzione Beretta CIAO Copyright © All rights reserved.