Home

SECO-LARM USA SK-910RC4Q User's Manual

image

Contents

1. ENFORCER SK 910RC4Q Central Receiver Manual a e Sa gt e 4 Channels e 4 Relay output modes e 4 Channel relay outputs e 4 Programmable alert tones e 1 Auxiliary relay output 12VDC e Upto 500 152m range SC SECO LARM Note Model numbers that end with Q or that have a round green Q sticker signify RoHS compliant products ENFORCER SK 910RC4Q Central Receiver Table of Contents IIFOGUGUOM annin 2 Alet Tones eccsssecee2 ensues toduosctactsnnacdahontonsdtsmeateeds 4 Specifications 85 fo5 vss ssicnaisedceswacescansicid aeveredete 2 Programming Each Channel Output 5 DIMENSIONS iai ned snseamivedicaeneaes 2 Setting the Timed Output eee 6 VICI OW ois cites tntedinades cites etic talus dactactatstnatea cee 3 Setting the Auxiliary Relay c cscs 6 Installation Notes cccccceeceesesses essere 3 Setting the Power LED ce eeseseeeeeees T Code Learning a New Transmitter 4 Sample Applications cece 7 Displaying or Clearing a Channel s Memory 4 TroubleShooting cece 8 Introduction The SK 910RC4Q Central Receiver is a four channel receiver with four independently controlled output modes and a unique volume adjustable alert tone for each channel This RF receiver is compatible with all ENFORCER transmitters both code hopping and fixed code The receiver can be used to remotely control a variety of home a
2. Locate the Alert Tones DIP switch marked SW7 Switches marked 1 through 4 determine whether each channel s sound will play when the respective channel is triggered 3 If the switch is in the ON position the alert tone will play when the channel is triggered 4 lf the switch is in the OFF position no alert tone will play when the channel is triggered 5 Adjust the volume using the volume adjustment knob Volume adjustment Alert Tones knob Channel 1 Doorbell Channel 2 Home Sweet Alert Tone Channel 3 Hame ae 4 SECO LARM U S A Inc ENFORCER SK 910RC4Q Central Receiver Programming Each Channel Output 1 Each channel output can be separately programmed for one of four different modes Timed Output When the channel receives a signal the relay will turn ON for 1 60 seconds depending on the output time set Note The timer once set is the same length for all outputs programmed for Timed Output See page 6 for timer programming Toggle Output When the channel receives a signal the relay will turn ON and remain activated until a second signal is received Latch Output When the channel receives a signal the relay will turn ON Turn the relay OFF by pressing that channel s programming button on the Central Receiver unit Validity Output When the channel receives a signal the relay will turn ON for as long as a signal is being received 2 To enter programming mode press the button marked Mode on the top of th
3. auxiliary relay terminals are the left most terminals on the terminal block as shown in the diagram below 2 Select which channels will trigger the auxiliary relay using the Auxiliary Relay DIP switch SW8 located on the PCB as shown in the diagram below 3 If the switch is in the ON position triggering the corresponding channel will activate the auxiliary relay 4 If the switch is in the OFF position triggering the corresponding channel will not activate the auxiliary relay Setting Auxiliary Relay Timer 1 Output time can be adjusted from 1 second to 10 minutes using the auxiliary relay output time potentiometer 2 Turning the potentiometer clockwise will increase the output time 3 Turning the potentiometer counterclockwise will decrease the output time Note Included power supply will not support loads larger than 500mA For larger loads replace with appropriate DC power supply Use the DIP switch to select the channel Default is Channel 1 ON Terminal Block Auxiliary relay terminals NOCOMNC NOCOMNC NOCOMNC NO COM NC 12VDC Output CH1 CH2 CH3 CH4 6 SECO LARM U S A Inc ENFORCER SK 910RC4Q Central Receiver Setting the Power LED The power LED can be set to Bright Dim or OFF using the power LED jumper 1 Locate the jumper on the PCB as shown below 2 Place the jumper on the middle and right pins for Dim and on the middle and left pins for Bright 3 Remove the jumper or plac
4. Per Channel Steady ON Receiving signal from transmitter OR indicates code has already been learned during code learning Fast flash In either code learning OR memory display OR channel output programming mode One flash A transmitter s code was learned OR channel relay is in Timed output mode Two flashes All learned codes were deleted OR channel relay is in Toggle output mode Three flashes Channel relay is in Latch output mode Four flashes Channel relay is in Validity output mode 0 15 flashes During normal operation press the programming button to display the number of codes stored 1 flash 1 code stored SECO LARM U S A Inc 5 ENFORCER SK 910RC4Q Central Receiver Setting the Timed Output When a channel is set to Timed Output triggering the channel will activate the relay for a set period of time Factory default is 1 second 1 The time can be set from 1 60 seconds using the Timer switches on the top of the receiver 2 Set switches according to the following chart NOTE The time set via the DIP switches applies to all channels programmed for Timed Output Top of unit Timer switches SW1 SW2 S 3 60 On On On Default setting i Setting the Auxiliary Relay Each channel may be individually set to activate a separately timed 12VDC output programmable from 1 second to 10 minutes The auxiliary relay provides up to 3A 12VDC 1 Connect the auxiliary device to the auxiliary relay The two
5. e on the left or right pin only to set the power LED to OFF 1 Aphotobeam sensor installed on a driveway E 960 D90Q or similar is connected to an RF wired transmitter SK 919TDWS BU or similar When the photobeam sensor is triggered the transmitter sends a signal to the SK 910RC4Q Central Receiver 2 Inside an alarm lamp or other signaling device is connected to the channel s relay output When the intruder triggers the photobeam sensor an alarm is triggered or the light turns on 3 Alternatively a DVR DR 1 series or similar can be connected to an RF wired transmitter When an event such as motion detection occurs on the DVR the transmitter sends a signal to the SK 910RC4Q Central Receiver alerting the user and activating the channel relay 4 In addition to connecting a signaling device to the channel relay output an auxiliary device such as an LED strobe light SL 1301 series or similar can be powered by the SK 910RC4Q Central Receiver when a channel is activated SECO LARM U S A Inc T ENFORCER SK 910RC4Q Central Receiver Troubleshooting The SK 910RC4Q will not read a e Check that the transmitter is operating within the transmitter it has already learned receiver s range e Check number of transmitters learned Learning more than 15 will cause the first transmitter learned to be deleted e Check that there are transmitter codes stored on the channel by pressing that channel s programming button once and cou
6. e unit Each channel s red LED will flash a number of times to show the current output mode that it is in of Flashes Output Mode of Flashes Output Mode 1 Timed Output 3 Laatch Output 2 Toggle Output 4 Validity Output 3 To change modes press the desired channel s transmitter programming button Each press moves to the next mode in the sequence shown in the diagram below After changing modes count the number of times the channel LED flashes to verify the channel is in the correct mode 4 When finished press Mode again to end programming Toggle Output 2 flashes Example 1 If the present mode is Timed Output and the desired mode is Latch Output press the channel s programming button 2 times aa oe Example 2 If the present mode is Validity Output and the desired mode is Latch Output press the Validity Output channel s programming button 3 times 4 flashes Programming Button Functions Per Channel Learn mode Press and hold the button for 3 seconds or more to enter Learn mode Clear memory Press and hold the button for 3 seconds or more When LED starts flashing press and hold again for 3 seconds to delete all learned codes LED will flash twice Reset Latch Output If channel is set to Latch Output press to turn relay off after it has been triggered Memory display Press momentarily The Channel LED will flash a number of times corresponding to the number of codes stored LED Indicator Functions
7. ed to weather moisture or high humidity To open the housing 1 Remove the antenna by unscrewing the antenna base counterclockwise 2 Remove the bottom cover starting from point 1 shown in the diagram Follow with points 2 and 3 NOTE Applying outward pressure on the clip points will help release the bottom cover 3 Before attempting to release point 4 gently slide the bottom cover down and left to bring the programming buttons out of their holes in the housing 4 Disconnect the speaker plug from the PCB to avoid damage while working with the cover off 5 When replacing the bottom cover ensure the speaker wires are not caught between the speaker and the PCB Check that buttons and knobs are properly inserted in their openings in the housing NOTE Buttons and knobs are connected directly to the PCB Be gentle to avoid damaging delicate electronics Do not force the cover on or off if resistance is felt SECO LARM U S A Inc 3 Clip Points ENFORCER SK 910RC4Q Central Receiver Code Learning a New Transmitter Each receiver channel can learn the codes of up to 15 different transmitters Transmitters are learned on a first in first out basis For example if 15 transmitter codes have been learned when a new transmitter is learned the first of the 15 codes that were learned before will be deleted 1 To learn a new transmitter first press and hold the programming button of the channel to be programmed for 3 seconds or m
8. nting the flashes The SK 910RC4Q is not in the correct e Programming modes change starting from the current relay output mode mode For example press the programming button 3 times to go from Toggle Output to Timed Output If necessary please review Programming Channel Output on page 5 Also Available from SECO LARM Single Button Transmitter LED Strobe Light Wired RF Transmitter J Baa SK 919TD1S UP SL 1301 BAQ Series SK 919TDWS BU Desktop Transmitter Dual Photobeam Sensor Electric Door Strikes SK 919TP2D P E 960 D90Q SK 990AQ WARRANTY This SECO LARM product is warranted against defects in material and workmanship while used in normal service for a period of one 1 year from the date of sale to the original consumer customer SECO LARM s obligation is limited to the repair or replacement of any defective part if the unit is returned transportation prepaid to SECO LARM This Warranty is void if damage is caused by or attributed to acts of God physical or electrical misuse or abuse neglect repair or alteration improper or abnormal usage or faulty installation or if for any other reason SECO LARM determines that such equipment is not operating properly as a result of causes other than defects in material and workmanship The sole obligation of SECO LARM and the purchaser s exclusive remedy shall be limited to replacement or repair only at SECO LARM s option In no event shall SECO LARM be liable for an
9. ore Programming buttons are found on the top of the unit Note A pencil or other pointed object may be necessary to press the programming buttons 2 The channel s red LED will flash quickly to indicate it is in Learning Mode DO NOT REPEAT STEP 1 WHILE THE LED IS FLASHING OR CHANNEL MEMORY WILL BE CLEARED 3 While the channel LED is flashing press the button of the transmitter being learned one time The channel s LED will flash once to indicate the transmitter code was successfully learned 4 lfno transmitter is learned within 15 seconds the receiver will return to standby mode 5 Ifthe transmitter has been learned already the channel LED will turn steady ON and the code will not be learned a second time Displaying or Clearing a Channel s Memory Display Channel Memory 1 Press a channel s programming button once 2 The number of flashes is the same as the number of transmitters that channel has learned Clear Channel Memory 1 Hold down the channel s programming button for three seconds 2 The channel s red LED will start flashing 3 After the LED has started flashing hold down the programming button for three more seconds The LED will flash two more times indicating that all codes learned by that channel have been cleared Alert Tones Each channel has a specific alert tone See the chart on the lower right 1 Open the housing following the instructions under Installation Notes on page 3 of this manual 2
10. utomation devices such as garage door openers lights motorized gates lifts and other devices Specifications Current draw arise 450mA 12VDC sound 500mMA 12VDC DC power supply included Relay type Form C NO NC COM Channels 1 4 relay rating 10A 12VDC RF frequenc 315MHz of RF channels Alert sound 100 3dB 10cm adjustable Number of alert tones 4 programmable 14 Pin terminal block Connectors 3 pins per relay 2 pin auxiliary output re X 33 16 a 40 167 F 40 75 C Actual range will vary greatly depending on the operating Operating temperature Included power supply will not support loads larger than 500mA amp vlonment For larger loads replace with appropriate DC power supply Dimensions P 4 26mm Front Bottom gt 59 46 135mm 2 SECO LARM U S A Inc ENFORCER SK 910RC4Q Central Receiver Overview Programming buttons Power Input Top Mode button 12VDC To antenna i Setting Transmitter programming 12VDC Timer switches Front aA Antenna ENFORCER Central Receiver Vol ume Speaker adjustment knob Status LEDs Bottom Auxiliary relay output 12vDc Main relay outputs Installation Notes 1 Mount in a convenient location where alert tones and LED indicators will be audible visible 2 Do not install in a location surrounded by metal as RF signals may be blocked decreasing range 3 Do not install in a location expos
11. y special collateral incidental or consequential personal or property damages of any kind to the purchaser or anyone else NOTICE The information and specifications printed in this manual are current at the time of publication However the SECO LARM policy is one of continual development and improvement For this reason SECO LARM reserves the right to change specifications without notice SECO LARM is also not responsible for misprints or typographical errors Copyright 2010 SECO LARM U S A Inc All rights reserved This material may not be reproduced or copied in whole or in part without the written permission of SECO LARM SECO LARM U S A Inc 16842 Millikan Avenue Irvine CA 92606 Website www seco larm com a MA PITsW1 Tel 800 662 0800 949 261 2999 Fax 949 261 7326 E mail sales seco larm com Pee esd Teo 8 SECO LARM U S A Inc

Download Pdf Manuals