1. SEARS OWNERS MANUAL MODEL NO 625 34440 CAUTION READ THIS MANUAL CAREFULLY BEFORE YOU USE YOUR PURIFIER SAVE THIS MANUAL Kenmore Countertop Water Purifier HOW IT WORKS CARE OF REPAIR PARTS Sears Roebuck and Co Chicago Ill 60684 U S A LIMITED WARRANTY FULL ONE YEAR WARRANTY ON WATER PURIFIER Except Carbon Filter For one year from the date of purchase Sears will repair this Water Purifier except carbon filter free of charge if defective in material or workmanship WARRANTY SERVICE IS AVAILABLE BY SIMPLY RETURNING THE WATER PURIFIER TO THE NEAREST SEARS SERVICE CENTER THROUGHOUT THE UNITED STATES This warranty gives you specific legal rights and you may have other rights which vary from state to state Sears Roebuck and Co Dept 702 PSP Sears Tower Chicago IL 60684 RULES FOR SAFE OPERATION OF YOUR WATER PURIFIER Before using your Purifier read these rules and instructions carefully Use your Purifier indoors on a dry level surface away from other heat sources This Purifier is recommended for use with pot able water supplies only DO NOT use for anything other than purifying water DO NOT attempt to purify and make safe drink ing water from non potable water sources Plug the Purifier into a 120 volt AC house electri cal outlet only KEEP CHILDREN AWAY HOT BOILING water in the Purifier
2. 6 Set the storage bottle cap removed with the opening right under the spout 7 Plug the power cord into any 120 volt outlet 8 Press the RESET button The fan motor in the cover begins to run check the cover cord plug in if it does not When the cycle is over the Purifier turns off automati cally AFTER THE FAN MOTOR GOES OFF WAIT AT LEAST 30 MINUTES BEFORE REMOVING THE COVER WARNING NEVER REMOVE THE COVER WHILE THE FAN MOTOR IS RUNNING OR FOR 30 MINUTES AFTER IT STOPS YOU COULD GET SEVERE BURNS FROM THE BOILING WATER OR STEAM 9 Unplug the Purifier power cord from the wall outlet 10 Replace the cap on the storage bottle and store in the refrigerator until you neet it 11 After the Purifier has cooled wait for 30 minutes after the fan motor stops running remove the cover and clean the tank BE SURE TO HOLD THE COVER BY THE TOP STRAP AS YOU REMOVE IT CARE AND CLEANING OF YOUR WATER PURIFIER WARNING ALWAYS BE SURE TO UNPLUG THE PURI FIER POWER CORD FROM THE WALL OUTLET BEFORE CLEANING OR BEFORE REPLACING PARTS STAINLESS STEEL TANK INSIDE After each use rinse the inside with luke warm tap water and remove any residue If a deposit Starts to form at the bottom use Sears Distiller cleaner Stock No 42 34543 Follow the instructions on the cleaner bottle Rub with a soft scouring pad and rinse thoroughly CAUTION DO NOT IMMERSE THE PURIFIER IN WATER OUTSIDE Wipe the
3. outside of your Purifier with a soft sponge and mild soap NOTICE THERE ARE NO USER SERVICEABLE PARTS INSIDE RETURN THE PURIFIER TO AUTHO RIZED SERVICE PERSONNEL FOR REPAIR SEE PAGE 6 CHANGING THE CARBON FILTER The carbon filters in the cover spout FIG 2 page 5 remove odors from the purified water Replace the continued page 5 CARE AND CLEANING OF YOUR WATER PURIFIER continued from page 4 Carbon Bag 2 carbon bags when you begin to get unwanted odor The filters will last 2 3 months if the Purifier is used every day They will last longer if you don t make purified water that often Get new carbon bags from Sears Stock No 42 34541 TO REPLACE Remove the cover from the tank Remove the carbon filter housing push IN and pull DOWN from the cover spout Remove the used carbon bags and throw away Carbon Filter Rinse the inside of the housing with water Housing Push new carbon bags down into the housing as far as they will go see step 7 on page 3 Replace the housing onto the cover spout and replace the cover on the tank The next time you make purified water discard the first 2 or 3 cupfuls which may have small harmless carbon fines in it NOTE The physiological effects of the operation of this appliance beneficial or otherwise have not been investigated by Underwriters Laboratories See Product Data Sheet for test data obtained from an independent laboratory PRO
4. BLEM CHECK LIST NOT MAKING ENOUGH STEAM COMING PURIFIED WATER FROM SPOUT EACH BATCH 1 Cover cord not NOT MAKING ANY PURIFIED WATER WATER LEAKS FROM SPOUT 1 Cover cord not Purifier power cord Carbon bags not not plugged into electrical outlet No power to electrical outlet Cover cord not plugged into Purifier base receptacle Did not press reset button to start cycle Did not fill the tank with tap water plugged into Purifier base receptacle Did not fill tank with water to max fill line Purifier cover gasket not sealing tightly on tank be sure gasket is down all the way around against bottom lip on cover see Key No 4 page 6 Storage bottle not placed directly under spout plugged into Purifier base receptacle pushed fully down into spout Spout not properly fastened to cover REPAIR PARTS SEARS WATER PURIFIER MODEL NO 625 34440 NO fog DESCRIPTION OF PART 6550067 Cover Assembly 42 34541 Carbon Filter package of 4 6550011 Filter Housing 6550013 Gasket 6550068 Tank Assembly 42 34552 Storage Bottle N 42 34543 Distiller Cleaner 6580181 Owners Manual N Replacement bottle may look different than illustrated Not illustrated t Notinciuded with Purifier NOTE Other than listed above the Sears Water Purifier has no other customer serviceable parts Should service be re
5. aste or odor in the purified water the first time you use it To remove any taste or odor causing matter do the following 1 Set the Purifier on your counter or tabletop 2 Looking at Fig 1 unplug the cover cord from its receptacle 3 Holding by the top strap lift the cover upward to remove then set aside 4 The storage bottle is inside the Purifier Pull it out and remove the cap Keep the cap in a handy place You will use it later 5 Rinse and fill the stainless steel tank with about 1 quarts of water 6 Put the cover onto the tank and plug the cover cord into the base receptacle 7 The 2 carbon filter bags are packed in a separate plastic bag Remove the carbon filter housing push IN and pull DOWN FIG 2 page 5 and push 1 carbon bag firmly down into the housing Follow with the second bag PUSH BOTH BAGS INTO THE HOUSING AS FAR AS THEY WILL GO OR WATER COULD OVERFLOW FROM THE HOUSING Place the housing push inward and upward on the cover 8 Place the storage bottle under the spout and plug the power cord into a wall outlet 9 Press the RESET button if needed pushed inward at the factory to turn the Purifier on fan motor begins to run When the bottle contains 2 or 3 cupfuls of water unplug the cover cord from the receptacle BUT DO NOT REMOVE THE COVER continued page 4 ALWAYS LIFT BY THE STRAP WHEN REMOVING THE COVER Cover Plug Into Spout 5 120V AC Carbon Filter HRS Electr
6. g cooking ice cubes salt restricted diets baby formulas steam irons photo processing and cleaning contact lenses By heating water to boiling the water is changed to steam which rises As the steam cools and turns back into water it is collected in the storage jug Impurities are left behind in the stainless steel tank continued page 3 HOW YOUR WATER PURIFIER WORKS continued from page 2 It takes about 6 hours and 5 minutes using cold tap water to make 1 gallon of purified water A plastic storage bottle that holds 4 quarts 1 gallon is in cluded with your Purifier Purified water will remain fresher tasting if it is kept tightly capped Also shaking the bottle before pouring will aerate the water and make it taste better Order extra storage bottles from Sears Stock No 42 34552 so you can chill one bottle of purified water while you make more IMPORTANT The Purifier uses small carbon filters in the spout to remove traces of odors before the purified water is collected in the storage bottle The filters last about 2 3 months A return of unwanted odor means the filters should be replaced Order replacement carbon filter bags from Sears Stock No 42 34541 BEFORE USING WATER FROM YOUR WATER PURIFIER FOR THE FIRST TIME Although care is taken so your Purifier and plastic storage bottle are clean some harmless matter may remain from manufacturing packaging or shipping This could leave an unwanted t
7. ical Housing Outlet gy Cord Reset Button BEFORE USING WATER FROM YOUR WATER PURIFIER FOR THE FIRST TIME _ continued from page 3 The remaining water will boil and pass through the system as steam to clean all surfaces 10 The Purifier shuts off automatically when the water has boiled away no more steam coming out of spout takes about 3 hours After this time unplug the power cord at the wall outlet 11 Shake the storage bottle then discard the 2 or 3 cupfuis of water which may have some harmless carbon fines very fine black particles in it from the filter MAKING PURIFIED WATER 1 Set the Purifier on your countertop or table 2 Unplug the cover cord from its receptacle FIG 1 Holding by the top strap lift the cover to remove and set aside 3 Fill the tank with tap water up to the max fill line 4 quarts The purifing cycle is shortened if you USE HOT WATER NOTE You can purify less than the full amount Use this chart as a guide DO NOT fill the tank with more than 4 quarts of water because the storage bottle will overflow WHEN YOU FILL WITH THE CYCLE TAKES COLD WATER TO ABOUT 1 qt 1 hr 35 min 2 at 3hrs 5 min 3 qt 4 hrs 35 min 4 qt max fill line 6hrs 5 min 4 Put the cover on the Purifier and plug the cover cord into the receptacle 5 Check to be sure the cover spout containing the carbon filter is locked in place
8. quired take the purifier to any Sears Service Center HOW TO ORDER REPAIR PARTS The model number of your Countertop Water Purifier is on the underside of the tank assembly WHEN ORDERING REPAIR PARTS ALWAYS GIVE THE FOL LOWING INFORMATION PART NUMBER PART DESCRIPTION MODEL NUMBER NAME OF ITEM _All parts listed may be ordered from any Sears Service Center If the parts you need are not stocked locally your order will be electronically transmitted to a Sears Repair Parts Distribution center for handling 6580181 1 93
9. will scald if spilled on skin DO NOT immerse any part of the Purifier in water THE HEATING ELEMENT IS IN THE BASE OF THE PURIFIER AND THE BOTTOM DOES GET HOT DURING USE BE SURE THE PURIFIER ISON A SURFACE ABLE TO WITHSTAND THIS HEAT AND AT LEAST 1 INCH AWAY FROM WALLS Do not let the electrical cord hang over the edge of the counter pinch in drawers or lay on open burner or other hot surface Do not use the Purifier if damaged or if the electrical cord is defective NEVER REMOVE THE COVER WHILE THE PURIFIER IS ON FAN RUNNING Let the unit cool at least 30 minutes after a cycle has finished THE BOILING WATER OR STEAM COULD CAUSE SEVERE BURNS Unplug your Purifier from the wall outlet when not in use when cleaning or when filling with water A A short power supply cord is provided to C If an extension cord is used 1 the marked reduce the risks of becoming entangled in or electrical rating of the extension cord should be tripping over a longer cord at least as great as the electrical rating of the appliance 2 the longer cord should be ar ranged so that it will not drape over the counter B An extension cord may be used if care is top or tabletop where it can be pulled on by exercised in its use children or tripped over HOW YOUR WATER PURIFIER WORKS The Purifier distills and turns ordinary tap water into clean clear purified water Uses for purified water include drinkin