Home

Sanyo VQM-801P User's Manual

image

Contents

1. LIVE PICTURE MODE LIVE PICTURE MODE OPERATIONS STEPS QUAD SCREEN OPERATIONS FULL SCREEN OPERATIONS VCR PLAYBACK MODE QUAD SCREEN OPERATIONS FULL SCREEN OPERATIONS MENU SETTING MODE LANGUAGE SETTING CLOCK AND SUMMER TIME SETTING CAMERA TITLE SETTING ALARM SETTING VIDEO SENSOR SETTING VIDEO SENSOR ALARMS TIMER SETTING CLOCK TITLE DISPLAY AND MONITOR SETTINGS esee VIDEO LOSS SETTING AND COMPUTER CONTROL SETTING ALARM DATA DISPLAY SETTING UP THE VCR SIGNAL OUTPUT SW IN AUTOMATIC SWITCHING SPEED ALARMS OPERATIONS EXTERNAL ALARMS VIDEO LOSS ALARM VIDEO SENSOR ALARMS RS232C CONTROL CONNECTION INTERFACE SPECIFICATIONS COMMANDS SPECIFICATIONS Date Time function Bl Up to 10 characters title function e Title and time display can be turned on off e Title and time display position can be selected Up to 100 alarm recordings log on screen display Timer function allowing to record only when necessary nig
2. LT ea 15 beooao iaso laput QUA A como 6999 Alarm input Monitor sold separately Timelapse VCR sold separately terminal a e Video input Video output terminal terminal Common For playback in Switching output quad screen only terminal NOTE With model VQM 801P use black and white cameras only colour cameras are used that may cause image beat etc English 5 CONNECTION REMOTE CONTROLLER CIRCUIT CONNECTIONS Use the layout below to make a remote controller and make the connections to the remote input pins RC C of the CONTROL terminal as indicated This will permit remote controlled operation of this unit make contact LOW input 2200 2200 3000 000000000000 CONTROL RCCSWCALC 12345678 p gt 232 3600 4700 6800 8200 1 2kQ SW switch SW 1 Camera 1 SW 2 Camera 2 SW 3 Camera 3 SW 4 Camera 4 SW 5 Camera 5 SW 6 Camera 6 SW 7 Camera 7 SW 8 Camera 8 1 8k0 9 2 2k0 10 3 3kQ SW 11 4 7kQ SW 12 7 5kQ SW 13 13kQ SW 14 27kQ SW 15 Still image Zoom Camera sequential display Quad screen VCR playback Live picture Menu selection INSTALLING THE RACK MOUNTING BRACKETS SOLD SEPARATELY To mount this unit onto a rack please use the r
3. N normal setting Quad screen A or B display QUAD ONLY e Either setting Y or N Quad screen A or B manual switching possible QUAD FULL e Either setting Y or Quad screen A or B manual switching possible Quad screen A or B automatic switching display SEQUENCE QUAD ONLY e Either setting Y or N Automatic switching of the display will depend on the quad screen A B settings entered in the TIMER SET menu QUAD FULL e Either setting Y or N Automatic switching of the display will depend on the quad screen A B settings entered in the TIMER SET menu Full screen display QUAD ONLY e N setting Quad screen A or B e Y setting Full screen display of a live picture manual switching possible QUAD FULL Either setting Y or Full screen display of a live picture manual switching possible Automatic switching display SEQUENCE 9 QUAD ONLY e N setting Quad screen A or B e Y setting Full screen display of a live picture Switched according to the setting entered in the menu QUAD FULL e Either setting Y or Full screen display of a live picture switched automatically according to the setting entered in the menu 23 MONITOR SET menu QUADONLY lt QUADFULL setting N normal setting CLOCK TITLE DISPLAY AND MONITOR SETTINGS Menu 7 Display when a switching signal input is present Table 2 B displa
4. SECURITY LOCK FUNCTION This function lets you lock the camera live picture mode or VCR playback mode so that it cannot be switched to another mode Security lock Press the LIVE or the VCR button for about 3 seconds The buzzer will be heard and all the buttons will be locked If a button is pressed by mistake the buzzer is heard and the corresponding function will not operate LIVE VCR 2 Canceling the Security Lock To cancel the security lock press the same LIVE or VCR button again for about 3 seconds A buzzer will be heard and the mode will be unlocked SETTINGS BACKUP FUNCTION This unit is equipped with a backup battery lithium battery to maintain the clock settings When the unit is used under normal conditions the backup battery is recharged The battery is fully recharged after a minimum of about 30 hours and will maintain the clock settings for up to 30 days NOTE The settings may not be maintained properly if the backup battery has been recharged for less than 30 hours when the power goes off Battery Life If the power is turned off for about one hour or more when the power is restored the CLOCK SET menu is displayed so the clock settings can be checked If the clock settings are reset to 01 01 2000 SAT 00 00 00 that may indicate that the battery is dead and must be replaced Replacing the Battery To replace the battery please consult your dealer After the battery has been replaced p
5. 1 2 Press the MENU button 4 times to display the ALARM SET menu Press the button to highlight the setting to modify Using the or button select the desired setting then press the button e Repeat step 3 until all the settings are as desired t Press the MENU button to go to the next menu screen or t Press the EXIT button to exit the menu display ALARM SET BUZZER iN DURATION RETRIGGER ALARM SET BUZZER ON DURATION RETRIGGER DATA VIDEO OUT DATA VIDEO OUT DOUBLE ALARM SWITCH DOUBLE ALARM SWITCH LIVE QUAD LIVE e ec ALARM SET menu BUZZER ON A buzzer will be heard when an alarm trigger is received Default setting OFF The buzzer will not be heard DURATION The alarm duration can be set to 1 2 3 4 5 10 Default setting 30 seconds CC NC CC The alarm will go on for as long as the alarm signal is received minimum 1 second NC The alarm will continue until canceled RETRIGGER To set if an alarm is received while the unit is already in alarm mode OFF The unit will not receive another alarm while one is already being received Default setting During alarm mode other alarm triggers will be received and the alarm duration will be extended DATA The camera number date time type of the alarm can be recorded To view the recorded alarm data refer to ALARM DATA DISPLAY on page 26 ON The alarm data is recorded Default s
6. MONITOR SET 2 E A FULL SEQ TIMER 4 Set the desired speed at which the full screen image will be switched The sequential display speed T1 or T2 setting is applied in the TIMER SET menu see page 21 The automatic switching speed is entered in seconds of interval 01 default 02 03 04 05 10 20 30 FULL SEQ TIMER T2 Set the desired speed at which the full screen image will be switched The sequential display speed T2 or T1 setting is applied to each camera in the TIMER SET menu see page 21 The automatic switching speed is entered in seconds of interval 01 default 02 03 04 05 10 20 30 OFF OFF The camera this setting is applied to will be skipped QUAD SEQ TIMER Set the desired speed at which the display will switch between quad screen A and B The automatic switching speed is entered in seconds of interval 01 default 02 O3 04 05 10 20 30 QUADONLY lt QUADFULL Y A quad screen and full screen display will be output to the monitor connected to the QUADONLY terminal N Default A quad screen only will be output to the monitor connected to the QUADONLY terminal NOTE For more information on the monitor displays please refer to Table 1 and 2 see pages 23 24 22 English CLOCK TITLE DISPLAY AND MONITOR SETTINGS Menu 7 Display when no switching signal input is present Table 1 MENITOR SET menu QUADONLY lt QUADFULL setting Image output at the VIDEO OUT terminal
7. 7 30 1 1 2 2 1 2 3 1 2 4 1 2 Camera 5 2 5 sec Camera 6 2 5 sec 7 2 5 8 2 5 F 13 VCR PLAYBACK MODE EI OUT Pire 7 Press the VCR button i ith t it ted t UE i The VCR playback mode is selected When a tape is played back the recording of the live pictures will be displayed on the monitor Refer to the diagrams below for the buttons to press in order to select the desired REO gus tion mod QUAD QUAD operation mode 4 O i If live pictures are recorded in full screen mode playback will only be available in full screen mode Quad screen playback of such a recording is not possible QUAD SCREEN OPERATIONS Press the QUAD button The camera select indicators 1 4 light and quad screen A is displayed NOTE Itis not possible to switch to quad screen B of the recorded pictures FULL SCREEN OPERATIONS Press a camera select 1 4 button The recorded pictures from the selected camera will be displayed full screen NOTE e In full screen and quad screen modes still and zoomed in image display modes are not possible e If the recording has been made using the quad screens A and B auto switching and if for example camera select button 1 is pressed the display will switch between the
8. on a live picture of the alarm trigger channel see page 20 mem Video sensor alarm Camera number RS232C CONTROL CONNECTION Connect a 9 pin D SUB cable sold separately from the RS232C terminal on the rear panel to the computer serial connector Computer CONTROL gt DOO OOOOOO OO OOC RS232C 9 pin D SUB cable sold separately Setting the Data Transmission Speed After the connection is made set the data transmission speed in the RS232C SET menu see page 25 INTERFACE SPECIFICATIONS For the RS232C terminal specifications refer to page 4 DATA FORMAT Mode Asynchronous 8 bits 2400 4800 9600 19200 bps set in the RS232C SET menu None One bit Character length Data transmission speed Parity check Stop bit TRANSMISSION PROTOCOL The transmission is based on 1 byte units After the computer has transmitted 1 byte it will wait for an answer from this unit then send the following byte of data The command ON F6 is sent to start and the command OFF F7 is sent to finish This unit will receive the commands and will reply to each command by ACK OA Refer to COMMAND TABLE 4 on page 31 COMMANDS COMMANDS AVAILABLE FROM THE COMPUTER 1 8 90 97 To select the picture from a camera to be displayed full screen QUAD 83 To display a quad screen SEQUENCE 87 In full scre
9. playback display mode quad screen or full screen display last selected Therefore when a mode is selected the display mode will remain the same e In quad screen mode if a camera is not connected at one of the input terminals NO VIDEO will be displayed on the monitor screen NO VIDEO NO VIDEO NO VIDEO NO VIDEO VCR Playback Mode see page 14 Start playback on the VCR If the video signal is correctly recorded the VCR playback image will be displayed when the VCR button is pressed English FRANCAIS DEUTSCH LIVE MENU Menu Setting Mode see page 15 Press the MENU button to display the menu The buttons used for menu control are indicated below Menu control buttons STILL ZOOM EXIT NEXT CD EXIT STILL button To exit the menu mode 2 NEXT ZOOM button To select a sub menu in order to set the title position etc Press the NEXT button to switch between the menu and the sub menu 8 QUAD SEQUENCE buttons Press repeatedly Use these buttons to select numbers letters symbols e button for forward selection e button for backward selection 4 P VCR LIVE button Press repeatedly Use these buttons to move the cursor to the right or down e button will move the cursor towards the right e W button will move the cursor down SEQUENCE QUAD LIVE ALL VCR MENU MENU RESET BASIC OPERATIONS
10. u Ta Selecting the quad screens A and B displayed cameras 21 Settings entered in the TIMER SET menu Automatic sequential switching speed delay set for each camera 21 22 Settings entered in the TIMER SET and the MONITOR SET menus English 9 QUAD SCREEN OPERATIONS Live picture Press the QUAD button once The camera select indicators 1 4 light and quad screen A is displayed Press the QUAD button one more time to switch to quad screen B NOTE The quad screen A or B last selected is memorised and will be selected first when switching to quad screen mode again Sequential display of quad screen A and quad screen B at 1 second interval Press the SEQUENCE button Quad screen A and quad screen B are displayed sequentially at 1 second interval The camera select indicators 1 4 5 8 light sequentially according to the displayed quad screen NOTE The sequential display speed screen interval is set to 1 second in the MONITOR SET menu The sequence speed setting can be set as desired refer to QUAD SEQ p TIMER on page 22 Selecting the quad screens A and B displayed cameras TIMER SETTING see page 21 Example 1 Quad screen A Quad screen B CAMERA 1 ON CAMERA 5 ON CAMERA 2 ON CAMERA 6 ON CAMERA 3 ON CAMERA 7 ON CAMERA 4 ON CAMERA 8 ON TIMER SET Example 2 CAMERA 1 OFF CAMERA 5 ON CAMERA 2 OFF CAMERA 6 ON CAMERA 3 OFF CAMERA 7 ON CAM
11. 5 di a2 d3 94 95 96 di a2 d3 94 Second byte 0 0 Bit state information 0 LIVE picture mode 1 VCR playback mode 000 Fullscreen 001 Quad screen ALARM ON 8 ALARM ON 7 ALARM ON 6 ALARM ON 5 ALARM ON 4 ALARM ON 3 ALARM ON 2 ALARM ON 1 LIVE VCR indication 3 bit indication of the display mode 010 Menu display Full screen mode 0000 Channel 1 0001 Channel 2 0010 Channel 3 0011 Channel 4 Quad screen 4 bit indication of the channels and quad screen displayed 7 6 5 4 3 2 1 0 Fourth byte 0 SENSOR 8 SENSOR 7 SENSOR 6 SENSOR 5 SENSOR 4 SENSOR 3 SENSOR 2 SENSOR 1 0000 Quad screen A 1 2 3 4 0001 Quad screen B 5 6 7 8 Menu display 0000 Menu 1 LANGUAGE LANG SPRACHE Menu 2 CLOCK SET Menu 3 TITLE SET Menu 4 ALARM SET Menu 5 VIDEO SENSOR SET Menu 6 TIMER SET 0001 0010 0011 0100 0101 0110 0111 1111 Fifth byte 0 Menu 7 DISPLAY SET Menu 8 VIDEO LOSS SET Menu 9 ALARM DATA VIDEO LOSS 8 VIDEO LOSS 7 VIDEO LOSS 6 VIDEO LOSS 5 Second byte Bit state information VIDEO LOSS 4 EXT ALARM indication EXTERNAL ALARM is ON VIDEO LOSS indi
12. ERA 4 OFF CAMERA 8 ON Camera number Example 3 Example 3 t th t be ONOFE dudas CAMERA 1 ON CAMERA 5 OFF Example 2 the night CAMERA 2 ON CAMERA 6 OFF Set the cameras to be ON OFF CAMERA 3 ON CAMERA 7 OFF during the day CAMERA 4 ON CAMERA 8 OFF Example 4 CAMERA 1 OFF CAMERA 5 OFF CAMERA 2 OFF CAMERA 6 OFF CAMERA 3 OFF CAMERA 7 OFF CAMERA 4 OFF CAMERA 8 OFF NOTE e When the timer is set the quad screen will be selected according to the day night settings e When the timer is not set the day setting quad screen will be selected 10 English QUAD SCREEN OPERATIONS Live picture Example To freeze the image from camera 4 1 Press the STILL button The STILL indicator flashes and the still image display mode is selected 2 Press the camera select 4 button The camera 4 indicator flashes the image from camera 4 is frozen and S flashes on screen gt To cancel the still image display mode Press the camera select 4 button one more time then press the STILL button Example To zoom in the image from camera 4 1 Press the ZOOM button The ZOOM indicator flashes and the zoomed in image display mode is selected 2 Press the camera select 4 button The camera 4 indicator flashes the image from camera 4 is zoomed in and 7 flashes on screen To cancel the zoomed in image display mode Press the camera select 4 button one more time then p
13. FULL SEQ TIMER QUAD SEQ TIMER QUADONLY QUADFULL Set the sequential display speed see page 22 English Press a camera select 1 8 button The camera select indicator lights and the live picture from the corresponding camera is displayed full screen NOTE In full screen mode still and zoomed in image display modes are not possible Sequential display of each camera pictures at 1 second interval Press the SEQUENCE button The pictures from each camera are displayed sequentially at 1 second interval The camera select indicators 1 8 light sequentially according to the displayed camera NOTE e The sequential display speed image interval is set to T1 or T2 in the MONITOR SET menu The default setting for T1 and T2 is 1 second see page 22 e The sequential display speed image interval T1 or T2 can be set for each camera in the TIMER SET menu Setting the sequential display speed for each camera 1 In the TIMER SET menu set the item SEQ 1 or 2 2 In the MONITOR SET menu set the desired speed for items FULL SEQ TIMER T1 and FULL SEQ TIMER T2 Example 1 Sequential display speed for daytime 7 30 AM 7 30 PM Camera 1 T1 2 sec Camera 2 T2 5 sec Camera 3 T1 2 sec Camera 4 T2 5 sec Camera 5 T1 2 sec Camera 6 T2 5 sec Camera 7 T1 2 sec Camera 8 T2 5 sec F Example 2 Sequential display speed for nighttime 7 30
14. INSTRUCTION MANUAL NYO VQC 801P VQM 801P Quad Compressor English Quad Compressor Deutsch Compresseur quadruplex Francais Compresor cu druple Espa ol Italiano Compressore per quadranti About this manual Before installing and using this unit please read this manual carefully Be sure to keep it handy for later reference This manual gives basic connections and operating instructions for 2 models Colour VQC 801P B W VQM 801P Uber diese Anleitung Lesen Sie bitte diese Bedienungsanleitung vor der Installation und der Verwendung des Ger tes sorgf ltig durch Bewahren Sie die Anleitung zum sp teren Nachschlagen auf In dieser Anleitung werden die Anschl sse und die Bedienungsanleitungen f r 2 Modelle Farbe VQC 801P Schwarzwei VQM 801P beschrieben propos de ce manuel Avant d installer et d utiliser cet appareil veuillez lire ce manuel attentivement Assurez vous de le garder port e de la main pour r f rence ult rieure Ce manuel couvre les instructions de branchement et d utilisation de base pour deux mod les couleur VQC 801P noir et blanc VQM 801 P Acerca de este manual Antes de instalar y usar este aparato lea detenidamente este manual Asegurese de guardarlo a mano para futuras referencias Este manual le indica las conexiones b sicas y las instrucciones de funcionamiento de dos modelos Color VQC 801P Blanco y negro VOM 801 P Nota su qu
15. LANGUAGE SETTING Menu 1 The default menu language is English The available language settings are English French and German Setting the language 1 Press the MENU button once to display the LANGUAGE LANG SPRACHE menu 2 Press the button to highlight the desired language 3 t Press the MENU button to go to the next menu or t Press the EXIT button to exit the menu display the selected language is set All the on screen menus and settings will be displayed in the selected language HORLOGE LANGUAGE LANG SPRACHE 01 01 2000 SAM 00 00 00 ENGLISH HEURE ETE MODE NON FRANCAIS SEM MOIS HEURE H MAR DER DIM 03 02 00 DEUTSCH ARR DER DIM 10 02 00 UHRZEIT 01 01 2000 SA 00 00 00 SOMMERZEIT EINST BETRIEBSART AUS WOCHE MT ZEIT EIN LZT SO 03 02 00 AUS LZT SO 10 02 00 16 English CLOCK AND SUMMER TIME SETTING Menu 2 CLOCK SET The default setting is as indicated below The clock will start after the actual time and date are set and the operations under SUMMER TIME SET are completed Default clock settings 01 01 2000 SAT 00 00 00 January 1 2000 at 00 00 1 Press the MENU button twice to display the CLOCK SET menu 2 Example Setting the clock to October 15 1999 at 3 20 PM CD Press the or button to set the day 15 then press the button 2 Press the or button to set the month 10 then press the button Press the or button to set t
16. M Press the or button to set the WEEK 2ND then press the button Setting 1ST 2ND 3RD 4TH or LST first second third fourth or last 2 Press the or button to set the WEEK TUE then press the button Setting SUN MON TUE WED THU FRI SAT or SUN Press the or button to set the MON 05 then press the button Setting 1 2 3 4 11 12 for January February March December Press the or button to set the TIME 03 then press the button e Following the same procedure as above set when the time is changed back from daylight saving time to standard time the OFF settings 3 t Press the MENU button to go to the next menu screen or t Press the EXIT button to exit the menu display 1 2 0 SIE TIME_SET IODE USE TIME SET MODE USE WEEK TIME 2ND SUN 03 02 00 OFF LST SUN 10 02 00 WEEK MON TIME ON LST SUN 03 02 00 ON OFF LST SUN 10 02 00 LIVE QUAD LIVE QUAD VCR ppp pp gt SUMMER TIME SET SUMMER TIME SET USE USE WEEK TIME WEEK MON TIME ON 2ND TUE 03 02 00 ON 2ND TUE 05 02 00 OFF LST SUN 10 02 00 OFF LST SUN 10 02 00 QUAD VCR QUAD VCR RP g gt 2 4 4 4 SUMMER TIME SET JODE USE WEEK TIME CAMERA TITLE SETTING Menu 3 When a picture from a camera is displayed on screen the camera number 1 to 8 is displayed at the bottom of the image You can enter a camera title su
17. a of the image on the screen to be used as a video sensor The video sensor detects movement in the selected area of the image and sends an alarm trigger that will initiate priority recording of the images from the concerned camera VIDEO SENSOR SET SETTING THE VIDEO SENSOR POSITION AND SENSITIVITY LEVEL Press the MENU button 5 times to display the video sensor setting screen The video sensor is displayed on the live picture from camera 1 Press the NEXT button repeatedly to select the video sensor setting screen for the other cameras N Using the V or gt button move the video sensor down or right to the desired alarm sensor area position Press the or button to raise or lower the sensor sensitivity level The available sensitivity levels are OFF not used 01 02 03 04 05 06 07 08 09 10 10 being the least sensitive 4 t Press the MENU button to go to the next menu screen or t Press the EXIT button to exit the menu display 1 Video sensor Ol LIVE CAM1 OFF e 3 L1 QUAD CAM1 03 4 Sensitivity Level 20 VIDEO SENSOR ALARMS Example If an alarm trigger is received for camera 4 in quad screen 1 The buzzer is heard and the camera 4 indicator light The alarm output changes from HI 5V to LOW OV 2 The image from camera 4 and the camera number 04 will be displayed SA Video Sensor Alarm will flash at the left of the
18. ack mount hardware model VA RACMK 1 sold separately 1 Insert the head of two of the supplied bolts into the keyhole opening on the side of the unit Insert the head of the bolt in the larger side then slide it to the smaller side of the opening Align the slot on the mounting bracket with the two bolts Make sure the bolts have not moved from their position then place a flat washer a locking washer and fix with a nut NOTE Make sure to use the bolts provided with this unit as the bolts provided with the rack mount hardware are too short Install the second mounting bracket on the opposite side then attach the unit onto the rack using the rack mount bolts English BASIC OPERATIONS MODE SWITCHING When the unit is connected to a power source the default display mode will be live picture from the four cameras 1 4 quad screen You can use the VCR LIVE and MENU buttons to switch to the desired mode see below for further information LIVE picture mode VCR playback mode LIVE picture mode Menu mode LANGUAGE LANG SPRACHE ENGL I SH Power on VCR Live Picture Mode see page 9 When the LIVE button is pressed the live direct picture from cameras 1 4 connected to the camera input terminals on the unit rear panel will be displayed While in live picture mode you can use the still and zoom functions NOTE e The unit will automatically start in the live picture or VCR
19. camera number Video sensor alarm Camera number Example of display when there is an alarm trigger ALARM SET BUZZER DURATION RETRIGGER DATA ON VIDEO OUT FULL 10 ON DOUBLE ALARM SWITCH ALARM SET BUZZER DURATION RETRIGGER DATA VIDEO OUT STILL ZOOM 10 ON DURATION RETRIGGER DATA ON VIDEO OUT QUAD STILL ON ZOOM ON NOTE The display mode quad or full screen selected for the alarm operation is set by the item VIDEO OUT in the ALARM SET menu see page 19 Resetting the Alarm e For an alarm in full screen display mode press the corresponding camera select button twice e For an alarm in quad screen display mode press the corresponding camera select button to switch to full screen display mode then press the corresponding camera select button one more time NOTE e During normal monitoring operations the camera select indicator lights according to the displayed camera If there is an alarm trigger for another camera the indicator will flash e When in quad screen A even if a video sensor alarm is triggered at a quad screen B camera the display will not switch to quad screen B English TIMER SETTING Menu 6 The timer can be set to record during the daytime and or nighttime According to the timer settings each camera picture full screen display switching speed can be set and the cameras to be displayed in the quad screens can be selected TIMER SET Daytime s
20. cation VIDEO LOSS is ON SENSOR indication SENSOR is ON VIDEO LOSS 3 VIDEO LOSS 2 VIDEO LOSS 1 Reserved 0 4 bit indication of the 0000 0001 0010 0011 0100 0101 0110 0111 Normal display mode Sequential display mode Zoomed in mode Still image mode Frozen zoomed in image Zoomed in still image Zoom range setting mode Zoomed in still image range setting mode display mode English 29 RS232C CONTROL COMMANDS AVAILABLE FROM THE QUAD COMPRESSOR ACK 0A Response when this unit receives a command NAK 0B Response if this unit did not receive the command ALARM BF When there is an alarm this command is sent as header Then the alarm information is sent in a 1 byte transmission see Table 3 ALARM information Table 3 Bit state information 2 bit indication of the 01 External alarms alarm type 10 Video loss alarms 11 Sensor alarms Reserved 0 Reserved 0 4 bit indication of the 0011 CAMERA NO 4 camera number 0010 CAMERA NO 3 0001 CAMERA NO 2 0000 CAMERA 1 OTHER COMMANDS ENTER 40 When numeric commands are all sent this command is used to enter the transmitted value CLEAR 56 To erase multiple byte commands 30 English RS232C CONTROL COMMAND TABLE TABLE 4 The commands available are indicated in
21. ch as the camera location up to 10 characters that will be displayed instead of the camera number TITLE SET Press the MENU button 3 times to display the TITLE SET menu Example To set the title GATE 1F for the camera 1 and HALL 2F for camera 2 Press the or button to set the first character then press the button By pressing the or button repeatedly the characters are selected as follows e Letters Y 2 e Numbers 0 1 8 9 e Symbols _ 2 Following the same procedure enter the rest of the title 1 Press the Y button to set the cursor at the first character location for camera 2 Press the or button to set first character H then press the button Following the same procedure enter the rest of the title ALL 2F t Press the MENU button to go to the next menu Screen or t Press the EXIT button to exit the menu display NOTE set the display mode for the title refer to DISPLAY SET CLOCK TITLE on page 22 LIVE QUAD VCR amp e 2 TITLE SET TITLE 1 GATE 1F__1 2 2 TITLE SET TITLE 1 GATE 1F__1 2 HALL 2F__2 3 English ALARM SETTING Menu 4 When an alarm trigger is received from sensors such as a door bell movement sensor etc you can set the display mode and the recording mode for the pictures from the concerned camera Changing the Settings
22. d until changed or cancelled 1 Press the ZOOM button The ZOOM indicator flashes and the zoomed in image display mode is selected 2 Press the camera select 4 button for about 3 seconds In full screen mode Z flashing and the zoom range frame are displayed NOTE If during the zoom range setting the displayed frame is not moved for about 10 seconds the display mode will automatically return to quad screen display mode To return to the setting mode press the camera select 4 button again for about 3 seconds 3 Press the gt or V button to move the zoom range frame to the desired area of the image 4 Press the camera select 4 button The area selected by the zoom range frame is now zoomed in If necessary follow the same procedure to set the zoom range for the other cameras NOTE You can switch from zoomed in mode to normal no zoom mode by pressing the camera select 4 button repeatedly t To cancel the zoomed in image display mode Press the ZOOM button 12 English FULL SCREEN OPERATIONS Live picture 200090006 SEQUENCE Camera number TIMER SET TIME 07 30 19 30 LX SEQ QUAD SEQ QUAD CAMi ON Ti OFF CAM2 T2 OFF 1 ON 111 ON 1 OFF CAM4 2 OFF Ti ON CAM5 T ON 2 OFF 2 OFF T2 ON 7 T1 T2 OFF 8 T2 OFF ON Example 1 Example 2 DISPLAY SET LIVE CLOCK OFF TITLE ON POSITION SET PRESS NEXT MONITOR SET
23. dle the power cord with wet hands Do not pull on the power cord when disconnecting it from an AC wall outlet Grasp it by the plug e If any liquid is spilled on the unit unplug the power cord immediately and have the unit inspected at a factory authorised service centre e Do not place anything directly on top of this unit SERVICE This unit is a precision instruments and if treated with care will provide years of satisfactory performance However in the event of a problem the owner is advised not to attempt to make repairs or open the cabinet Servicing should always be referred to your dealer or Sanyo Authorized Service Centre CAUTION Danger of explosion if battery is incorrectly replaced Replace only with the same or equivalent type recommended by the manufacturer Discard used batteries according to the manufacture s instructions English 1 CONTENTS FEATURES PARTS NAMES FRONT PANEL 229 ux sados nel REAR PANEL urna rto qt aom CONNECTION RECORDING LIVE PICTURES IN QUAD SCREEN DISPLAY MODE ONLY CONNECTIONS REMOTE CONTROLLER CIRCUIT CONNECTIONS INSTALLING THE RACK MOUNTING BRACKETS SOLD SEPARATELY BASIC OPERATIONS MODE SWITCHING SECURITY LOCK FUNCTION SETTINGS BACKUP FUNCTION RESET FUNCTION
24. e from that camera is displayed ON or not OFF when in quad screen mode during the daytime TIMER SET Nighttime NAE NULL 07 3 Press the button then using the or button select the switching speed T1 or T2 in the second SEQ w column for camera 1 Ti This sets the duration the image from camera 1 is n displayed when in full screen mode during the nighttime period Press the button then using the or button select ON or OFF in the second QUAD column for camera 1 This determines if the image from that camera is displayed ON or not OFF when in quad screen mode TIMER SET TIMER SET during the nighttime p mE MD 1 2 1 NOTE The settings for the sequential display speeds 1 CAMA Ti and T2 are entered in the MONITOR SET menu Bans CAM7 T1 4 t Press the MENU button to go to the next menu imi Screen or t Press the EXIT button to exit the menu display English 21 CLOCK TITLE DISPLAY AND MONITOR SETTINGS The clock and the camera title settings entered in the menus LIVE CLOCK CLOCK SET and TITLE SET can be displayed on screen ON The clock is displayed during live picture mode SETTING THE CAMERA TITLE AND THE OFF The clock is not displayed during live picture mode Default setti CLOCK DISPLAY POSITION POSITION SET Dorai seima LIVE TITLE 1 Press the MENU button 7 times to displa
25. en mode the display will be switched in order automatically In quad screen mode the display will switch between quad screen A and B automatically ZOOM 85 To zoom a picture in quad screen STILL 86 To freeze a picture in quad screen LIVE 80 To select the live input mode VCR 81 To select the VCR playback input mode MENU 74 To display the menu or switch to the next menu 65 66 To select settings for the menu items ON OFF etc 63 64 To change selection in the menus To move the cursor right down NEXT 75 To switch to the sub menus EXIT 76 To go to the next menu or to exit the menu mode MENU RESET E1 To reset all the values of the displayed menu to the default values CLOCK ADJUST E0 To reset the clock minutes and seconds setting to 00 00 SECURITY LOCK ON 69 To set the security lock SECURITY LOCK OFF 6A To cancel the security lock English RS232C CONTROL INFORMATION GATHERING COMMANDS STATUS SENSE D7 When this command is sent from the computer this unit will send a 5 byte response see Table 1 RXD TXD STATUS SENSE D7 byte assignment Table 1 The third fourth and fifth bytes are reserved First byte ALARM STATUS SENSE D5 The external video loss and video sensor alarm states are indicated by a 6 byte response see Table 2 RXD fs TXD ALARM STATUS SENSE D5 byte assignment Table 2 First byte 9
26. er as illustrated A AC Power socket Insert the power cord female plug firmly into this socket When the other plug of the power cord is connect to a live power source the POWER indicator on the front panel will light CONTROL 00000000000000 RCCSWCALC 12345678 Ec RS232C terminal HEH e EH Function Signal direction Data reception Computer gt This unit Data transmission This unit gt Computer Normally H Common No reception This unit Computer oo RON Signal Remote input Common Switching input DC 5V Common Alarm input DC 5V Common Alarm input 1 Alarm input 2 Alarm input 3 Alarm input 4 Alarm input 5 Alarm input 6 Alarm input 7 C 1 2 3 4 5 5 7 8 Alarm input 8 English CONNECTION Before making any connection make sure all the devices are turned off Before making the connections please refer to the instruction manual accompanying each device If the devices are not connected properly that may cause a fire and or damages RECORDING LIVE PICTURES IN QUAD SCREEN DISPLAY MODE ONLY CONNECTIONS BBE Live pictures in quad screen full External alarm sensors door bell interphone etc A ed A ee ee TEOT a ONLY RCCSWCALC 12345678
27. esto manuale Leggere attentamente questo manuale prima di passare all installazione ed all uso di questo apparecchio Questo manuale contiene istruzioni per i principali collegamenti ed il funzionamento di due modelli il modello a colori VQC 801P ed il modello in bianco e nero VQM 801P PRECAUTION WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK DO NOT EXPOSE THIS APPLIANCE TO RAIN OR OTHER MOISTURE To avoid electrical shock do not open the cabinet Refer servicing to qualified personnel only If the power supply cord AC power cord of this appliance is damaged it must be replaced Return toa SANYO Authorised Service Centre for replacement of the cord Location For safe operation and satisfactory performance of your unit keep the following in mind when selecting a place for its installation e Shield it from direct sunlight and keep it away from sources of intense heat e Avoid dusty or humid places e Avoid places with insufficient ventilation for proper heat dissipation Do not block the ventilation holes at the top and bottom of the unit Do not place the unit on a carpet because this will block the ventilation holes Install the unit in a horizontal position only Avoid locations subject to strong vibrations Avoid moving the unit between cold and hot locations Do not place the unit directly on top of a monitor TV as this may cause interference Avoiding Electrical Shock and Fire e Do not han
28. etting OFF The alarm data is not recorded ON English 19 ALARM SET BUZZER ON DURATION 10 S RETRIGGER ON ON FULL DATA VIDEO OUT ALARM SET BUZZER ON DURATION RETRIGGER DATA VIDEO OUT DOUBLE ALARM SWITCH ALARM SET BUZZER ON DURAT ON 10 RETRIGGER ON DATA ON VIDEO OUT QUAD STILL OFF OFF ZOOM FULL If an alarm trigger is received while in quad screen the picture from the camera corresponding to the alarm input will be displayed full screen Default setting DOUBLE ALARM This item is only displayed and can only be set if VIDEO OUT above is set to FULL SWITCH The picture from each concerned camera will be displayed sequentially at 1 second interval Default setting FIRST The picture from the first alarm received only is displayed LAST The picture from the last alarm received is displayed VIDEO OUT B QUAD If an alarm trigger is received while in full screen the display mode will switch to quad screen STILL ON The image from the camera corresponding to the alarm trigger will be frozen OFF The image will not be frozen Default setting ZOOM ON The image from the camera corresponding to the alarm trigger will be zoomed in OFF The image will not be zoomed in Default setting VIDEO OUT C NC The display mode will remain unchanged when an alarm trigger is received VIDEO SENSOR SETTING Menu 5 You can set an are
29. he year 1999 then press the button Press the or button to set the hours 15 then press the button Press the or button to set the minutes 20 then press the button NOTE The day of the week SAT will be automatically set according to the date entered t Press the Y button to go to the SUMMER TIME SET menu t Press the MENU button to go to the next menu screen or t Press the EXIT button to exit the menu display 2 0 2 0 6 CLOCK SET __ CLOCK SET 15 01 2000 SAT 00 00 00 15 10 1999 FRI 15 20 00 QUAD VCR QUAD LIVE pP eE NOTE set the display mode for the clock refer to DISPLAY SET CLOCK TITLE on page 22 SUMMER TIME SET The default summer time function setting is NO USE so the summer adjustment will not be made If the unit will be used an area where there is a summer time change set it to USE then if necessary set when the summer time is changed The default settings are Summer time from the last Sunday of March at 2 00 AM LST SUN 03 02 00 to last Sunday of October at 2 00 AM LST SUN 10 02 00 English TO MAKE CHANGES TO THE SETTINGS 1 Press the Y button to highlight the NO USE setting then press the or button to select USE and press the Y button one more time 2 Example Setting the summer time from the second Tuesday of May at 3 00 to the fourth Tuesday of September at 3 00 A
30. ht and or day for each camera e Sequential speed for each camera can be adjusted e Important cameras to be displayed in quad screen can be selected Wi Video loss warning function that can switch the display to colour bars or to a frozen image 3 alarm functions External alarm video loss alarm video sensor alarm Security lock function Computer control function using an RS232C connection ACCESSORIES D Power cord x1 2 Fixer Power cord tie x1 3 Rack mounting brackets bolts x4 a English PARTS NAMES FRONT PANEL RESET STILL ZOOM SEQUENCE QUAD LIVE VCR MENU MENU RESET i i i 1 Q This unit is not equipped with a power switch The power is turned on off when the supplied power cord is connected disconnected at the power source D POWER indicator D LIVE button and indicator 2 Camera select buttons and camera indicators Press this button to select the live input mode Use these buttons to select the picture from the VCR button and indicator corresponding camera When a camera is selected the Press this button to select the VCR playback input mode corresponding indicator will light MENU button see page 7 2UEE buton and indicator Press this button to display the menus Press repeatedly to In live picture quad screen display mode press this button select the different menus in order Buttons to are to set the freeze m
31. images from camera 1 and camera 5 Full screen sequential display at 1 second interval Press the SEQUENCE button The pictures are displayed sequentially at 1 second interval The camera select indicators 1 4 light sequentially according to the displayed camera NOTE e The sequential display speed image interval is set in the MONITOR SET menu To change the sequence speed setting refer to FULL SEQ TIMER on page 22 e The sequential display speed image interval FULL SEQ TIMER T1 or T2 can be set for each camera in the TIMER SET menu SEQUENCE 14 English MENU SETTING MODE MENUS DISPLAYS To display the menus press the MENU button Menu 1 Menu 2 CLOCK SET LANGUAGE LANG SPRACHE b 01 01 2000 SAT 00 00 00 ENGL I SH SUMMER TIME SET MODE NO USE WEEK TIME STILL STILL FRANCAIS ON LST SUN 03 02 00 DEUTSCH nu oun P CP inna OFF LST SUN 10 02 00 EXIT EXIT STILL B ALARM SET BUZZER ON DURATION 10 S RETRIGGER OFF DATA ON VIDEO OUT FULL MENU DOUBLE ALARM SWITCH e Monitor Wee Erro TIMER SET TIME 00 00 CAM1 CAM2 CAM3 CAM4 CAMS CAM6 CAM7 SEB return VIDEO LOSS SET VIDEO LOSS ON DATA ON DISPLAY FREEZE RS232C SET DATA SPEED 192 ALARM DATA 1 CAM DATE TIME Normal live picture display English 15
32. is heard and the camera 4 indicator flashes The alarm output changes from HI 5V to LOW OV 2 The image from camera 4 and the camera number 04 will be displayed EA External Alarm will flash at the left of the camera number The action taken here will depend on the settings entered in the ALARM SET menu see page 19 External alarm Camera number NOTE e When the alarm operation is over the display will return to the mode preceding the alarm trigger e An alarm trigger can also be received at a terminal for which a camera is not connected to In such a case a grey screen will be displayed e The display mode quad or full screen selected for the alarm operation is set by the item VIDEO OUT in the ALARM SET menu Resetting the Alarm e For an alarm in full screen display mode press the corresponding camera select button twice e Foran alarm in quad screen display mode press the corresponding camera select button to switch to full screen display mode then press the corresponding camera select button one more time NOTE e The alarm display mode is selected according to the settings entered in the DISPLAY SET menu e During normal monitoring operations the camera select indicator lights according to the displayed camera If there is an alarm trigger for another camera the indicator will flash English If there is an interruption of the video signal the buzzer is heard and the image j
33. nal LT ki SEQUENCE QUAD FULL e N setting Full screen display of a live picture switched automatically according to the setting entered in the menu Y setting Automatic switching of a full screen display of a live picture according to the switching signal input at the SW terminal The minimum switching speed delay will be 1 second 24 English VIDEO LOSS SETTING CONTROL SETTING AND COMPUTER VIDEO LOSS SET When the live picture signal feed is interrupted you can set the action taken and if the video loss is recorded as alarm data This function will only operate in quad screen display to select it set VIDEO LOSS to ON Setting the Video Loss Mode 1 2 Press the button to highlight the setting to modify Using the or button select the desired setting then press the button Following this procedure select the settings for DATA and DISPLAY t Press the button to go to the next menu or t Press the MENU button to go to the next menu Screen or t Press the EXIT button to exit the menu display VIDEO LOSS SET VIDEO LOSS ON DATA DISPLAY LIVE VIDEO LOSS SET menu VIDEO LOSS You can set the action to take when there is an interruption in the video signal feed ON When there is video loss the image just previous to the interruption is frozen on screen or colour bars are displayed see DISPLAY right and VIDEO LOSS is dis
34. ode used for menu control ZOOM button and indicator In live picture quad screen display mode press this button to set the 2x zoom in mode 5 SEQUENCE button and indicator Press this button for an automatic sequential quad screen or full screen display of the pictures 6 QUAD button and indicator In live picture mode press this button repeatedly to switch between quad screens A and B ALL RESET button see page 8 MENU RESET button see page 8 SS English 3 PARTS NAMES REAR PANEL e CAMERA 185 2586 367 49e 00060000 O IN FULL VCR VIDEO QUT o QUAD CAMERA input terminals 1 8 VCR IN Video cassette recorder input terminal VCR OUT QUAD FULL Video signal output terminal Output in quad screen and full screen display modes VCR OUT QUAD ONLY Video signal output terminal Output only in quad screen display mode However the output display mode at this terminal can be switched from quad screen mode only to quad screen and full screen display modes see MONITOR SET on page 22 and Tables 1 and 2 on pages 23 and 24 RS232C RS 232C terminal To control this unit using a personal computer connect the computer serial terminal to this terminal using a 9 pin D SUB cable sold separately CONTROL terminal Battery compartment Power cord holder Using the supplied tie attach the power cord to the hold
35. odify Using the or button select the desired setting The available speeds are 2400 4800 9600 19200 Default setting bps 3 t Press the MENU button to go to the next menu screen or t Press the EXIT button to exit the menu display 1 2 VIDEO LOSS SET VIDEO LOSS ON DATA DISPLAY FREEZE RS232C SET _____ DATA SPEED 119200 LIVE amp ALARM DATA SETTING UP THE VCR DISPLAY Menu 9 SIGNAL OUTPUT SW IN AUTOMATIC SWITCHING SPEED According to the settings entered in the ALARM SET VIDEO SENSOR SET and VIDEO LOSS SET menus information about the alarms alarm data can be recorded Up to 100 alarm data entries can be displayed on screen on up to 13 screens 1 Connect the unit SW IN terminal to the VCR SW OUT ALARM DATA terminal see page 5 Displaying the Alarm Data 2 Set the VCR recording speed The settings entered for the SEQ TIMER in menu 7 MONITOR 1 Press the MENU button 9 times to display the ALARM SET will be ignored and the full screen image and quad screen DATA menu A and B switching speeds will be the speed set by the VCR e The first screen 1 13 of alarm data entries is displayed NOTE 2 To display the next screen of alarm data entries press e Even if the screens switching speed is set to a very quick the NEXT button timing the minimum switching speed delay will be 1 second e Even when the switching timing is set using the SW IN 1 gt Press
36. played on screen Default setting OFF When there is video loss NO VIDEO is displayed on screen NOTE If no camera is connected to one of the terminals then NO VIDEO will be displayed on a grey screen This will not trigger a video loss alarm DATA You can set the data date time etc of the video losses to be recorded as alarm data To view the recorded data refer to ALARM DATA DISPLAY on page 26 ON The video losses data is recorded as alarm data Default setting OFF The video losses data is not recorded English 25 DISPLAY You can set the display mode when there is an interruption in the video signal feed FREEZE When there is video loss the image just previous to the interruption is frozen on screen Default setting When there is video loss colour bars are displayed on screen NOTE If the VIDEO LOSS SET menu DISPLAY is set to FREEZE when there is a loss of the video signal VIDEO LOSS and the image just previous to the interruption will be shown frozen on screen To switch to a colour bars display press the camera select button or QUAD button RS232C SET Connect this unit to a computer using a 9 pin D SUB cable sold separately then set the maximum communication speed with the computer For detailed information refer to RS232C CONTROL page 28 TEST Changing the Setting 1 2 Press the button to highlight the setting to m
37. ress the ALL RESET button then in the CLOCK SET menu set the date and time see page 17 RESET FUNCTION The menus can be reset or cleared MENU RESET Using the MENU RESET Button A While a menu is displayed press the MENU RESET button to reset all the values of the displayed menu to the default values B If no menu is displayed press the MENU RESET button to reset the time to the nearest hour NOTE For example between 10 30 00 and 11 29 59 the clock will be reset to 11 00 00 Using the ALL RESET button Press this button to reset the following e Reset the time and date in the CLOCK SET menu to the default setting e The display will return to the default quad screen display mode If the unit does not function properly press the ALL RESET button Please note that all the settings mentioned above will be reset English LIVE PICTURE MODE an OUT riera Press the LIVE button perations with the monitor connecte to the VIDEO OUT QUADFULL The live pictures from the cameras connected to the CAMERA terminals 1 4 on the unit terminal back panel will be displayed pene eee n eee eee enon eeeeeceseceseceseeeeee Refer to the diagrams below for the buttons to press in order to select the desired operation j mode LIVE PICTURE MODE OPERATIONS STEPS Automatic switching between quad screen A and SEQUENCE Quad screen A BI Nem m
38. ress the ZOOM button Example To freeze the zoomed in image from camera 4 1 Press the ZOOM button The ZOOM indicator flashes and the zoomed in image display mode is selected 2 Press the camera select 4 button The camera 4 indicator flashes the image from camera 4 is zoomed in and 7 flashes on screen 3 Press the STILL button The STILL indicator flashes and the ZOOM indicator lights 4 Press the camera select 4 button The camera 4 indicator flashes the zoomed in image from camera 4 is frozen and SZ flashes on screen X NOTE To use the zoom function again first cancel the still image display mode gt t To cancel the still and zoomed in image display mode Press the camera select 4 button then press the STILL button Press the camera select 4 button then press the ZOOM button t To cancel all the still image displays and zoomed in image displays Press the STILL button then press the ZOOM button English 11 QUAD SCREEN OPERATIONS Live picture The zoomed in area is set by the frame position 8 e button will move the frame to the right e W button will move the frame down Example To zoom in the image from camera 4 and set the zoom range You can select the portion of the image to zoom in The default zoomed in area is the centre of the image but if a different zoom range is selected it will be memorize
39. screen Full screen VS VBS 1 0 Vp p 75 BNC connector x 1 Composite output Quad screen only VS VBS 1 0 Vp p 75 Q BNC connector x 1 Push type terminal No voltage make contact switch input x 8 Low input 2 wire type with resistance based identification system can be used with a remote control circuit DC 5V 5 7 kQ Low output 1 low input for switching signal from SW OUT of a timelapse VCR as per this manufacturer specifications 9 pin D SUB Title up to 10 characters date time selectable 9 menus screens Internal 8 channel each camera input selectable Back up for up to 30 days of the clock settings after connected for 30 hours continuously Available for camera live in quad screen full screen and zoomed in picture Can be set using a menu to operate automatically when there is an alarm trigger Available for camera live in quad screen 8 settings 1 2 3 4 5 10 20 and 30 seconds interval available in full screen mode and quad screen A and B 220 240 v 50 Hz 16 W VQC 801P 14 W VQM 801P 5to 40 C 10 to 80 420 W x 44 H x 325 D mm Approx 3 4 kg Products are subject to change in design and specifications without notice and without incurring any obligation 32 English SANYO SANYO Electric Co Ltd 1AC6P1P2092 L8QR5 L8QS5 XE 0799KP NIO1 Printed in Japan
40. tart time end time TIMER SET 9 Press the MENU button 6 times to display the TIMER TIME 00 00 00 00 SET menu eb i 2 Set the daytime period start and end times ON Example To set the daytime period from 7 30 AM to on a 7 30 PM the nighttime will then be from 7 30 on 11 to 7 30 Using the or button select the starting hour 7 the first part of the first setting of the TIME line 2 Press the button then using the or button select the starting minutes 30 the second part of the first setting of the TIME line Press the button then using the or button select the end hour 19 the first part of the second setting of the TIME line Press the button then using the or button select the end minutes 30 the second part of the second setting of the TIME line Daytime setting area Nighttime setting area TIMER SET 3 Set the timer operations for each daytime nighttime period Daytime Press the W button then using the or button select Tae A IMER SET T ME IER SED the switching speed T1 or T2 in the first SEQ column for camera 1 This sets the duration the image from camera 1 is displayed when in full screen mode during the daytime period 2 Press the button then using the or button select ON or OFF in the first QUAD column for camera 1 This determines if the imag
41. the EXIT button to exit the menu display terminal signal the minimum switching speed delay will be 1 t Press the MENU button to return to the normal second see page 24 picture then press the MENU button once more to display the menu display 2 ALARM DATA CAM DATE TIME 4 22 08 08 21 05 04 ALARM DATA CAM DATE TIME 4 5 Se om lt m lt mMoma m zo 03 13 03 05 02 11 02 29 O05 0N oOdv 1 2 1 3 1 4 1 5 1 6 1 7 1 8 1 ZOOM The codes the ITEM column indicate the type of alarm data E External alarm trigger see page 27 V Video loss see page 25 27 S Video sensor alarms see page 20 27 NOTE e When the number of recorded alarm data entries reaches 100 the oldest ones are erased as new ones are recorded e The alarm data screens are only displayed when alarm data entries are recorded 26 English ALARMS OPERATIONS There are three types of alarms the alarms set by an external alarm trigger the alarms set by a loss of the video signal and the alarms set by the video sensor EXTERNAL ALARMS VIDEO LOSS ALARM When external inputs such as a door bell an interphone etc are connected to the CONTROL terminal pins 1 8 they will send alarm triggers automatically On the monitor screen the alarm display will identify the camera corresponding to the alarm trigger Example If an alarm trigger is received for camera 4 in quad screen 1 The buzzer
42. the table If a function is not available on the unit the command will not operate even if sent 8 LIVE VCR PB VERSION MULTI SHIFT QUAD MENU PLUS NEXT ZOOM EXIT STILL SEQ SECURITY LOCK ON SECURITY LOCK OFF POWER ON OFF SET ON SET OFF 0 1 2 3 4 5 6 7 8 9 A B C D E F E CLK ADJ MENU RESET ALARM STATUS SENSE STATUS SENSE English 31 SPECIFICATIONS Signal format Camera signal input synchronization Camera input terminals CAMERA VCR input terminal VCR IN VIDEO output terminal 1 VIDEO OUT QUAD FULL VIDEO output terminal 2 VIDEO OUT QUAD ONLY Control terminal CONTROL e Alarm input 1 8 Remote input RC Alarm output AL e Switching input SW RS 232C terminal Monitor on screen display Menu settings Video alarm sensor Back up function Operations e Still e 2x zoom Display automatic switching speed Power Consumption Operating temperature range Operating humidity range Dimensions Weight Based on PAL colour signal standard VQC 801P Based on PAL B W signal standard VQM 801P Asynchronous VS VBS 1 0 Vp p 75 BNC connector x 8 Composite input VS VBS 1 0 Vp p 75 Q BNC connector x 1 Composite output Quad
43. ust previous to the interruption is frozen on screen or colour bars are displayed and VIDEO LOSS will flash on screen The action taken will depend on the settings entered in the VIDEO LOSS SET menu see page 25 NOTE e f a video signal is not present from the beginning then NO VIDEO will be displayed on a gray screen This will not trigger a video loss alarm e The video loss alarm is recorded until the video signal is restored e In full screen display mode video loss alarm is not possible Resetting the Alarm e Foran alarm in full screen display mode press the corresponding camera select button e Foran alarm in quad screen display mode press the corresponding camera select button to switch to full screen display mode Then press the corresponding camera select button one more time NOTE e The alarm display mode is selected according to the settings entered in the ALARM SET menu e During normal monitoring operations the camera select indicator lights according to the displayed camera If there is an alarm trigger for another camera the indicator will flash e If the alarm is not reset VIDEO LOSS will be displayed until normal live picture signals are restored VIDEO SENSOR ALARMS The video sensor area is set in the VIDEO SENSOR SET menu The brightness and contrast levels in the video sensor frame are used to trigger the alarm and the alarm display type of alarm and camera number is shown
44. y Quad screen A or Image output at the VIDEO OUT terminal QUAD ONLY e Either setting Y or Quad screen A or B manual switching possible QUAD FULL Either setting Y or Quad screen A or B manual switching possible B automatic SEQUENCE 0 Quad screen A or switching display QUAD ONLY e Either setting Y or Automatic switching of quad screen A B according to the switching signal input at the SW terminal The minimum switching speed delay will be 1 second QUAD FULL Either setting Y or Automatic switching of quad screen A B according to the switching signal input at the SW terminal The minimum switching speed delay will be 1 second Full screen display QUAD ONLY e N setting Automatic switching of quad screen A B according to the switching signal input at the SW terminal The minimum switching speed delay will be 1 second Y setting Full screen display of a live picture manual switching possible QUAD FULL Either setting Y or Full screen display of a live picture manual switching possible Automatic 9 switching display QUAD ONLY N setting Automatic switching of quad screen A B according to the switching signal input at the SW terminal The minimum switching speed delay will be 1 second Y setting Automatic switching of a full screen display of a live picture according to the switching signal input at the SW termi
45. y the DISPLAY po PPS SET menu ON The camera title is displayed during live picture mode Default setting 2 Using the or button select the desired setting OFF The camera title is not displayed during live picture mode then press the V button e Following this procedure select the settings for LIVE CLOCK and TITLE MONITOR SET Fromthe DISPLAY SET menu press the NEXT button You can set the sequential display speed T1 and T2 and the The quad screen A display is selected quad screen A and B switching speed Switching the display 4 Usina th ith title displ mode on the monitor connected to the VIDEO OUT QUAD or button set the O OY ONLY terminal from quad screen to full screen display is also position Select among the 3 positions possible in this menu 5 Using the button set the clock display position These FULL and QUAD SEQ TIMER settings must only be done when not using a SW IN signal 6 Press the NEXT button The display will return to the When using a SW IN signal please refer to Setting up the DISPLAY SET menu VCR signal output SW IN automatic switching speed on t Press the MENU button to go to the next menu page 26 screen or rs Press the EXIT button to exit the menu display MONITOR SET menu 3 Quad screen A Press the W button to select the desired item then using the DISPLAY SET or button select the desired setting T POSITION SET RESS NEXT FULL SEQ TIMER T1