Home

Sanyo STB0810C1 User's Manual

image

Contents

1. CYCLE The direction of the heated or cooled air may be adjusted by removing and turning the louvers around To change the louver direction remove the front grille and 1 louver screw that hold the louvers in place Turn the louver section 180 end for end replace the screws and replace the front grille The textured face of the louver section must be facing toward the room side Front grille Louver screw i WI ii EF Front Grille amp Wall Case Control Panel Outdoor Coil Base Pan Front Grille Removal appearance may vary Air Filter appearance may vary Condenser Coils Care and Cleaning Wash the front grille and wall case finish with mild soap or detergent and lukewarm water The control panel is shipped with a protective plastic film This film can be left on or removed To clean use a damp cloth and mild detergent The coil on the outdoor side of the unit should be checked periodically and cleaned if clogged with dirt or soot from the atmosphere If extremely dirty it may need to be professionally steam cleaned In some installations dirt or other foreign matter may be blown into the from the outside and settle in the base pan the bottom of the unit Check the base pan periodically and clean it out if necessary The front grille can be removal for more through cleaning or to make the model and serial numbers accessible The air filter behind th
2. PUTA s dli WA mi LOW LOW Mind M55 Thermostat E Mode P 4 selector WARMER COOLER us Vuoi Thermostat Control Mode Selector The thermostat knob is used to control the room temperature The unit automatically cycles on and off to maintain room temperature A comfortable temperature will be maintained in most rooms when the control is set to about intermediate range HI HEAT provides heating with high fan speed operation LOW HEAT provides heating with low fan speed operation OFF setting stops heating or cooling operation However power remains connected to the unit Hi FAN Lo FAN provides fan operation without cooling or heating HI COOL provides cooling with high fan speed operation LO COOL provides cooling with low fan speed operation Operation How to stop the air conditioner How to restart the air conditioner N een Control Panel and Operation Functions continued THERMOSTAT setting temperature guide Cooling Only Model Cool Heat Model ermediat ermediat iu range i range e a P d J a 55 F 88 F a a Y 55 F COOLER WARMER COOLER 1 Set the mode selector for fan cooling or heating operation 2 Set the thermostat to the desired position Refer to the setting temperature guide above 3 Set the operation selector switch The above temperatures are provided for reference only and may dif
3. SANYO INSTRUCTION MANUAL STB Series Cool Only Models 26 Through The Wall STBOS10C1 Air Conditioner STB1010C1 STB1020C1 STB1220C1 Cool Heat Models STBO811C1 STB1023C1 STB1123C1 Save These Instructions Pub Ol 85164119637001 OSANYO 2000 Contents Page Product Information sssssssssseseseee nennen tenente tnnt setenta 2 Alert Symbols tice is 2 Installation Location ssssesesesesseeeeeeennen nennen nnne trenes tenen nnne 3 Electrical Requirements eessesissseeeeeeee enne nnne nnne nennen 3 Safety Instr CLtloris uccisi rtt rie DUE CRUEL ERE RE even a dre ARE e X ERR RUBER Rte ds 3 Names of Parts eret eene Dec uae LO oda Gr shape mre d Ge Eu ERR Re ndn 4 Control Panel and Operation Functions sssssseeeeeneen 5 Other Features cete A a e tee i ns 7 Care and Cleaning eines nennen nnne nnne entren nennen 8 Tips for Energy Saving cte eite ve EL eed UD es 9 Tro bleshootirg ier ia dis 10 Product Information If you have problems or questions concerning your Air Conditioner you will need the following information Model and serial numbers are on the nameplate of the cabinet Model No Serial No Date of purchase Dealer s address Phone number Alert Symbols The following symbols used in this manual alert you to potentially dangerous conditions to users serv
4. e front grille should be checked and cleaned at least every 30 days or more often if necessary Clean the filter with a vacuum cleaner to remover light dust It can also be washed in warm soapy water The coils on the weather side of the air conditioner should be checked regularly If they are clogged with dirt or soot they may be professionally steam cleaned a service available through your Sanyo service outlet XS Z lt cA NN Ol 602 10EG OI 602 11EG Do not Tips for Energy Saving Block the air intake and outlet of the unit If they are obstructed the unit will not work well and may be damaged Let direct sunlight into the room Use sunshades blinds or curtains If the walls and ceiling of the room are warmed by the sun it will take longer to cool the room Keep the air filter clean Refer to Care and Cleaning A clogged filter will impair the performance of the unit To prevent conditioned air from escaping keep windows doors and any other openings closed Keep the ventilator closed for economy and maximum cooling Keep outdoor condenser coil clean It s best to operate your air conditioner at high speed during extremely hot or cold weather Troubleshooting PROBLEM POSSIBLE CAUSE AND REMEDY AIR CONDITIONER DOES NOT OPERATE Not plugged in Plug may have been bumped loose by vacuum cleaner or furniture If plugged in fuse could have blown or circuit break
5. e this only for its intended purpose as described in this Instruction Manual Never use or store gasoline or other flammable vapor or liquid near the air conditioner it is very dangerous Never use an extension code with this air conditoner Do not tum the air conditioner on and off from the power mains switch Use the mode selector switch Do not stick anything into the air outlet of the unit This is dangerous because the fan is rotating at high speed Do not let children play with the air conditioner Do not cool or heat the room too much if babies or invalids are present Names of Parts Air outlet E r E 7 Cover switch and JJ control panel gt j Air intake SN u Front grille Air Intake Air from the room is drawn into this section and passes through air filters which remove dust Air Outlet Conditioned air is blown out of the air conditioner through the air outlet 4 Ol 602 04EG Ol 602 05EG Control Panel and Operation Functions Cool Only Mode THERMOSTAT SELECTOR o e Thermostat N Mode selector Cool Heat Model THERMOSTAT SELECTOR LOWEAN cH
6. er may have been tripped AIR CONDITIONER DOES NOT HEAT OR COOL AS IT SHOULD Curtains blinds or furniture blocking front of air conditioner will restrict air flow Thermostat Control may not be set high or low enough Also when Fan Switch is at CYCLE the temperature in the room will vary more than when it s at CONTINUOUS Turn knob to another number Highest setting should provide maximum cooling The lowest setting should provide maximum heating Air filter dirty should be cleaned at least every 30 days Room may have been very hot or cold when air conditioner was first turned on Allow time for it to cool down or warm up Conditioned air may be escaping through open furnace floor registers and cold air returns Cooling coils have iced up To melt ice set the Fan at high speed and the Thermostat Control to a lower number WATER LEAKS INSIDE Air conditioner is not installed level Install level or tilt slightly toward the outside WATER LEAKS OUTSIDE Excess water may overflow in extremely hot and humid weather This is normal 10 NOISY OPERATION When compressor or fan switches on and off a metallic knock may be heard This is normal Something is hitting or vibrating inside the cabinet Turn off air conditioner and consult your dealer OI 602 12EG In Canada SANYO FISHER COMPANY SANYO Canada Inc A DIVISION OF SANYO NORTH AMERICA CORPORATION 300 Applew
7. fer from the actual temperature of the room To stop the air conditioner set the mode selector to OFF position To restart the air conditioner set the mode selector to desired position 1 If the unit is tumed off during cooling and heating DO NOT restart it immediately as this can damage it Wait at least three minutes before starting it again 2 Freezing Up If you notice that your air conditioner is not cooling as it should it may be that ice has formed on the cooling coils The ice blocks air flow and stops the unit from cooling the room This freezing up is a temporary condition that most often occurs at night when the Thermostat is set on the coldest setting and the Selector is set on LOW COOL To correct the condition set the Selector at H or L FAN or HIGH COOL with the Thermostat with tuming the thermostat knob to the opposite direction from COOLER O1 602 06EG Ventilation Control Fan Switch To Adjust the Air Direction Ol 602 03EG Other Features The Vent Control is located behind the front grille When set at CLOSE only the air inside the room can be circulated and conditioned When set at OPEN some indoor air can be exhausted from the room The Fan Switch is located under the control panel To reach it you need to remove the front grille knobs and the control panel Remove the front grille to adjust the louvers side to side VENT CLOSE OPEN FAN CONT
8. ice personnel or the appliance WARNING This symbol refers to a hazard or unsafe practice which can result in severe personal injury or death practice which can result in personal injury or product or property damage CAUTION This symbol refers to a hazard or unsafe Ol 602 02EG AU Installation Location We recommend that this air conditioner be installed properly by qualified installation technicians in accordance with the Installation Instructions provided with the unit Before installation check that the voltage of the electric supply in your home or office is the same as the voltage shown on the nameplate Do not install this air conditioner where there are fumes or flammable gases or in an extremely humid space such as a greenhouse Do not install the air conditioner where excessively high heat generating objects are placed Electrical Requirements 1 All wiring must conform to the local electrical codes Consult your dealer or a qualified electrician for details 2 Each unit must be properly grounded with a ground or earth wire or through the supply wiring 3 Wiring must be done by a qualified electrician OI 602 03EG AUS N Sra Safety Instructions Read this Instruction Manual carefully before using this air conditioner If you still have any difficulties or problems consult your dealer for help This air conditioner is designed to give you comfortable room conditions Us
9. ood Crescent 21605 Plummer Street Concord Ontario Chatsworth CA 91311 U S A L4K 5C7 Canada